Loading...
HomeMy WebLinkAboutDoor to Window Repair DetailsGarage Existing Sliding Glass Door to be removed and Li In opening to be filled in to g 6068 receive a new window R Om S.G.D. Existing Header to remain Light & Switch' Existing C.B.S. Existing Header 1, to remain Block Walls ry] Existing Floor Plan Scale: 1/8' = V-0"" 8,-0„* TOB _ Existing Header to remain Existing C.B.S. 6;-8„ Btm. of Existing H_dr. _ Block Walls Orie #5 Horiz. rebar in G11out Filled CBS course Precast Cono. Sill or Masonry Opening Drill and Epoxy ends into 2500# Cast In Place for 72" x 26" Window existing Jambs Sill 5r rDrill d rebar New Floor Plan ':':':-:..-.-.---:— --....... - =-__.- _� Epoxy -into t theexisting „sting amb 5""and ex into Scale: 1/4 = V-0 ...... .'.:. ...': Filled Grout 'i ed CBS 5" ew Gro . : . YPical 5 5"" se Two-part epoxy to .. .: nchgr the #5 rebar in place. Simpson Epoxy -Tie or Hilti 0-100 c= New CBS In Fill ., _c Existing Existing C.B.S. C.B.S. " r Grout i Filled 0.00' FFE — _ EXISTING ROOF ASSEMBLY TO REMAIN i In Fill Detail Scale: 3/4" V-0" EXISTING DRYWALL 1 x 2 P.T. FIRESTOP WINDOW EXISTING BOND BEAM ABOVE DOOR OPENING TO REMAIN 2500# CAST IN PLACE OR PRECAST SILL 6068 8 x 16 x 8 C.M.U. S.G.D. (SEE IN FILL DETAIL) TWO COAT 1 x 2 P.T. FURRING 24"o.c. STUCCO FINISH R4.2 FOIL INSUL Existing Elevation OVER FURRING Scale: 3/16" V-0" 1/2" GYP. D.W.-".. 1x2P.T. FIRESTOP New Window 0.00'- FFE — I GRADE — I I I New In Fill I I ( EXISTING CONC. I I FOUNDATION New Elevation Wall Section Scale: 3/16" = V--0" Scale: 3/4" =1'-0" C.M.U. the ling i� ,5 ro 3 in vi ad U 3 Z Scope of Work Design Loads Remove the existing Sliding Glass Roof Live Load: N.A. Door and replace with a new Fixed Floor Live Load: N.A. Glass Window (72 x 26 "). Fill in the Wind Speed: 160 MPH Remainder of the opening with CBS. Wind Importance Factor: 1.0 Building Category: II Building Code Wind Exposure: B Internal Pressure'Coefficent: .18 2020 Florida Building Code: Residential Structure Designed: Enclosed 2020 Florida Building Code: Existing Soil bearing capacity: 2000 p.s.f. Buildings: Alteration Level II Building Data Occupancy Type. Group R Construction Type: V Number of Stories: One Product Approval Affidavit Form Category Approval Numbers Manufacturer Model Number Glass Type Attachment Method Building Design Product Rated Pressures Design Pressures WINDOWS Head & Sill: 6- from comers and 12.5"o.c. Jambs: 6- HOrIZ. Slider' FL#: 16735.1 Custom Window Systems HS-8200 Impact from corners and 17"o.c. and 3"& 6"on each side of meeting rail at Head and Sill. Use 3/16"Tapoons with + 33.5 -44.8 +/- 50.0 1 1/4-embedment into concrete. I 3/8" continuous bead of caulk (back bedding) behind buck to prevent liquid passage set flange in continuous bead of caulk across the entire face of buck _,. CBS a a . Min. 1 1/4" embedment ° ° , at windows Q C ° ° a c ° 1/2" drywall I GENERAL REQUIREMENTS All work to be as per the current edition of the Florida Building Code and meet or exceed all applicable local requirements. Genaf aT contractor to check all drawings for errors and ommissions and bring them to the attention of the architect prior to starting any work, or ordering any materials of the respective division of work. if such errors and ommissions are not reported in writingto the architect, any resulting damages or costs shall be born entirely by the general contractor. Architect is not responsible for the' contractors method or means of construction. Unless otherwise noted, the installation of specified hardware shall conform to the manufacturers instructions and standardpractice. All plans and drawings are not considered complete until they have been reviewed and approved by the St. Lucie County Building Department and the building permit has been issued. stucco finish STRUCTURAL NOTES: 1/4"" max. struct. shim All reinforcing steel shall be high strength billet steel and shall perimeter caulkJ conform to ASTM A-615 grade 60 specifications. Lap continuous caulk reinforcing Attach p.t. bucks g 48 bar diameters or 30"" in beams and in slabs. Lap with 8d coil nails at 7attach as per bottom steel over supports and top steel at midspan. Hook 12-o.c. manufacturers discontinuous ends of all top bars. Reinforcing steel shall have product approvals a minimum of 1 "concrete cover, or as follows: Typical window BOTTOM TOP SIDES jamb Apply LWM200 Liquid Applied Waterproofing on all jambs and 8"on the face of the CBS Beams: 1 1/2" 1 1/2" 1 1/2" around window opening. Slab on Grade: 1 1/2" 1" NOTE: Method of attachment and Gunable sealants shall comply with Structural Poured: 3/4" 3/4" _ waterproofing procedures are the ASTM C 920 Class 25 grade or Poured Walls: _ _ 3/4" same at poured concrete sill. greater for proper joint expansion Slabs exposed and contraction to the weather 3/4- ill Reinforcing steel shall be detailed and fabricated in accordance Window & Door Flashing Detail at CBS Wall with the "Manual of Standard Practice of Detailing Reinforcing Includes Buck Attachment Method Concrete Structures`" and the current "ACI Building Code 318" All structural steel shall conform to current ASTM Specification A-36 window All wood in contact with masonry shall be pressure treated or approved frame corrosive resistant separating material. Tapcon concrete 3/8" continuous bead of srews installed as All dimensions shall be verified in field by the contractor. If there are caulk (back bedding) behind specified in window any discrepancies the Architect or Engineer shall be notified before shim to prevent liquid passage manufacturers product proceeding. approval 1/4" struct shi window sill All Design and Construction shall be'inaccordance with the current set flange in continuous American Concrete Institute (ACI). and the American Institute of Steel bead of caulk across the Construction (AISC), The Florida Building Code and all applicable entire face of buck local codes. perimeter caulk Structural Concrete shall attain a minimum ultimate compressive strength stucco finish (Fc') in 28 days as follows: Column and walls from foundation to roof: 3000 p.s.i. e :r All other concrete: 3000 P.S.I. a sealants shall comply with ASTM C 920 Class 25 grade or e. ° n All wood members shall have a minimum fiber stress in bending ASTM e . greater for proper joint expansion of 1200 p.s.i. with 1 /360 max. deflection. and contraction precast cono. sill BUCK ATTACHMENT NOTES Apply LWM200 Liquid Applied Waterproofing on all jambs and 8"on the face of the CBS AT WINDOWS USE P.T. PINE OR SPRUCE AND ATTACH around window opening. BUCKS TO BLOCK WITH 8d CASED HARD COIL NAILS Typical Precast Conc. Sill Detail OR "T" NAILS- 4" FROM ENDS AND 8"o.c. drawn 8.1. checked I s.I. date 1/26/2021 scale as noted job number 21004 O sheet A-1 REVIEWED FOR _0 O E COMPLIANCE T LUCCIE COUNTY BOCC