HomeMy WebLinkAboutProduct Approval R301.2.1.2 Protection of openings. Glazed openings in buildings located in windborne debris regions shall be protected from windborne debris. Glazed opening protection for windborne debris shall meet the requirements of the Large Missile Test of ASTM E 1996 and ASTM E 1886 referenced therein, SSTD 12, TAS 201, 202 and 203 or AAMA 506, as applicable. The applicable wind zones for establishing misile types in ASTM E 1996 are shown in Section R301.2.1.2.1. Garage door glazed opening protection for windborne debris shall meet the requirements of an approved impact-resisting standard or ANSI/DASMA 115. 1. Opening in sunrooms, balconies or enclosed porches constructed under existing roofs or decks are not required to be protected provided the spaces are separated from the building interior by a .wall and all openings in the separating wall are protected in accordance with this section. Such -space shall be permitted to be designed as either partially enclosed or enclosed structures. 2. Storage sheds that are not designed for human habitation and that have a floor area of 720 square feet(67 m2) or less are not required to comply with the mandatory wind-borne debris impact standard of this code. Exception: Wood structural panels with a minimum thickness of inch (11 mm) and a maximum span of 8 feet(2438 mm) shall be permitted for opening protection in one-and two-story buildings. Panels shall be precut and attached to the framing surrounding the opening containing the product with the glazed opening. Panels shall be predrilled as required for the anchorage method and shall be secured with the attachment hardware provided. Attachments shall be designed to resist the component and cladding loads determined in accordance with either Table R301.2(2) or ASCE 7, with the permanent corrosion-resistant attachment hardware provided and anchors permanently installed on the building. Attachment in accordance with Table R301.2.1.2 is permitted for buildings with a mean roof height of 33 feet(10 058 mm) or less where Vasd , determined in accordance with Section R301.2.1.3, does not exceed 130 miles per hour(58 m/s). TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELSa,b, c, d �A FASTENER SPACING (inches)a,b FASTENER Panel 4 feet< 6 feet< TYPE span panelspan panelspan <_4 feet 5 6 feet <_8 feet No. 8 wood screw based anchor with 2-inch embedment 16 10 8 length No. 10 wood screw based anchor with 2-inch embedment 16 12 9 length 1/4-inch lag screw based anchor with 2-inch embedment 16 16 16 length 'For SI: 1 inch = 25�4 mm, 1 foot= 304.8 mm, 1 pound =4.448 N, 1. mile per hour= 0.447 m/s. -a. This table is based on 130 mph wind speeds and a 33-foot mean roof height. b. Fasteners shall be installed at opposing ends of the wood structural panel. Fasteners shall be located a minimum of 1 inch from the edge of the panel. c. Anchors shall penetrate through the exterior wall covering with an embedment length of 2 inches minimum into the building frame. Fasteners shall be located a minimum of 21/2 inches from the edge of concrete block or concrete. Florida Building Code Online File Cop?,age 1 of 5 BCIS Home Log In User Registration Hot Topics i Submit Surcharge Stats&Facts Publications FBC Staff , BCIS Site Map Links Search j Florida ]ONCEALED FASTENE OR ATTACHMENTS ` r �A��USER:Public Use royal ARE THE RESPONSIBILITY OF THE L P.•f1tY9�-.6Ain Y Product Approval Menu>Product or Application Search>Application List>Application Detail �l./'<I TRACTOR ���( �� (i� �l FL# FL14911-R7 1l��I t f 4ry t Application Type Revision Code Version 2014 Application Status Approved THESE PLANS AND ALL PROPOSED WORK - ARE SUBJECT TO ANY CORRECTIONS Comments Archived 0 10'EQUI# ED BY MELD INSPECTORS THAT a;�IY ICE NECESSRY:IN ORDER TO {; Product Manufacturer Silverline Building Products Corp. t :..Or. PI.�` ,L'41 PLIC' �CODES.. Address/Phone/Email One Silverline Drive �; _a. _.. North Brunswick,NJ 08902 (800)234-4228 Ext4644 Jonberrian@slbp.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Jon Berrian Address/Phone/Email One Silverline Drive r, —� s;;Tti ' Dt"dC�PtrSi�'i� North Brunswick,NJ 089b'2�' I CL_, �L J., .. (732)435-1000 j?FF!TF`T�'Ll1I'lRCQNO-LIANCE Jonberrian@slbp.com B / HATE L Quality Assurance Representative IPLA NS A`dD PER'ttT HUST BE KEPT ON JOB Address/Phone/Email Cr T D MPECMINT WILL BE KkDE. Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer L�l Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F. Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity Window and Door Manufacturers Association-QA Quality Assurance Contract Expiration Date 08/03/2021 Validated By Ryan J. King, P.E. W Validation Checklist-Hardcopy Received Certificate of Independence FL14911 R7 COI Certificate Of Independence(2).12df Referenced Standard and Year(of Standard) Standard Year AAMA/W DMA/CSA/101/I.S.2/A440 2008 AAMA/WDMA/CSA/101/I.S.2/A440 2011 ASTM D1929 1996 ASTM D2843 1993 ASTM D635 1996 ASTM D638 1996 ASTM E1886 2005 ASTM E1996 2009 ASTM G26 1995 TAS 201, 202 and 203 1994 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquZRj 5 9%2fDrx... 6/26/2017 Florida Building Code Online Page 4 of 5 ! i ' 14911.13 m.Series 2100/Model 2111 Extruded Vinyl Single Hung Window-Flange Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R7 II Inst 14911.13.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14911.13 for Design Pressure Ratings, FL14911 R7 AE Eva] 14911.13.pdf any additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 14911.14 n.Series 2200/2300-Model Extruded Vinyl Single Hung Window-Nailing Fin 2201/2301 Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R7 II Inst 14911.14.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14911.14 for Design Pressure Ratings, FL14911 R7 AE Eval 14911.14.odf any additional use limitations, installation instructions and Created by Independent Third Party:Yes product particulars. 14911.15 o.Series 2200/2300-Model Extruded Vinyl Twin Single Hung Window-Nailing Fin 12202/2302 (Continuous Head and Sill with Integral Mullion) Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 R7 II Inst 14911.15.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 14911.15 for Design Pressure Ratings, FL14911 R7 AE Eval 14911.15.1)df any additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 14911.16 p.Series 2200/2300-Model Extruded Vinyl Triple Single Hung Window-Nailing Fin 12203/2303 (Continuous Head and Sill with Integral Mullion) Limits of Use Installation Instructions Approved for use in HVHZ:No FL14911 R7 II Inst 14911.16.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14911.16 for Design Pressure Ratings, FL14911 R7 AE Eva] 14911.16.Ddf any additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 14911.17 q. Series 2907 Model 2907 Single Hung Extruded Vinyl Window with Nailing Fin Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R7 II Inst 14911.17.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 14911.17 for Design Pressure Ratings, FL14911 R7 AE Eval 14911.17.pdf any additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 14911.18 r.Series 2907 Model 2907TW Twin-Continuous Head&Sill Single Hung Extruded Vinyl Window with Nailing Fin Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R7 II Inst 14911.18.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See INST 14911.18 for Design Pressure Ratings, FL14911 R7 AE Eval 14911.18.odf any additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 14911.19 s.Series 2907 Model 2907TR Triple-Continuous Head&Sill Single Hung Extruded Vinyl Window with Nailing Fin Limits of Use Installation Instructions Approved for use in HVHZ: No FL14911 R7 II Inst 14911.19.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 14911.19 for Design Pressure Ratings, FL14911 R7 AE Eval 14911.19.pdf any additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 14911.20 t.Series 70 Model 2127 Extruded Vinyl Single Hung Window-Nailing Fin http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDquZRj 59%2fDrx... 6/26/2017 Silverbneo byAndersen - z g` z WINDOWSeDOORS -� ��`` u_WI ' > .. ,o�m 5325'MAX OVERALL FLANGE WIDTH �i c`� u,$"' lil l l llt .i rA Z 52.0"MAX.OVERALL FRAME WIDTH Al;� o=U `� ago 9 10. l\ ina p=a SERIES 2100 — M ODEL 2111 / M o cz m a a m EXTRUDED VINYL ;/ $ ra SINGLE HUNG WINDOW O W 0 _ ~o w/ FLANGE W w w Z �/ 3 Z W S � O,U "NON-IMPACT' g _ � Uj W 0 o / 23 p F —W i En 0 0I a a a of GENERAL NOTES ^ X m a LL 1. This product has been evaluated and is in compliance with the Sth Edition(2014)Florida Building / m Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone"(HVHZ). q z v ti 2. Product anchors shall be as fisted and spaced as shown on details.Anchor embedment to base N 3 material shall'be beyond wall dressing or stucco. V1 z wZ O a 3. When used in areas requiring wind bome debris protection this product is required to be G protected with an impact resistant covering that complies with Section 1609.1.2 of the FBC. o e 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x o y • buck masonry construction. - Z OVERALL OVERALL MAX GLASS DESIGN PRESSURE(PSG m FLANGE FRAME D L.Q J 5. Site conditions that deviate from the details of this drawing require further engineering analysis by 7YpE DIMENSION OIMENSION DIMENSION POSITIVE NEGATIVE,': N a Qo cc a licensed engineer or registered architect. 37.25"x 63.25" 36.0"x 62.0" 31.69"x 28.0" +50.0 -50.0 Z IT N O O TABLE OF CONTENTS 46.25"x 63.25" 45.0"x 62.0" 40.69"x 28.0" G1 +40.0 -40.0 DATE: 10/24/1z1 z d SHEETS DESCRIPTION scA- N.T.S. 1 Typical elevation,design pressures&general notes 53.25"x 74.25" 52.0"x 73.0" 47.69"x 33.50" +30.0 -30.0 DWG.BY: KV 'm 2 Horizontal&vertical cross sections 3 CHK,BY: LFS 3 Buck&frame anchoring BRAWING No.: 4 Bill of materials,glazing detail&components FL-14911.13 i a N SHEET 1 of 4 V a R.\Clients\Silverline Building_Products-P1Flodda Product Approvals\FL-14911\C-Drawings\FL-14911(2014)\FL-14911.10-16.dwg,Z16 LnA N—+ v Z G a Q N + N N A N I W ON m. N W O � Oo Bm � F T z Z �O Z 1 114,MIN. EM&TYP. Q Z 0 rF m N Ga A N A � � 1J O A �n N O r Z 4��tiv nO O ATAOZ ON+ O N' 0 N mmfi" v V n W H = A 1 1/4"MIN. Q EMB.TYP. r� N a N Q+ A N tp v A a N O N N d ' n 30 e o e� Z m O ed. Do Om +p 0 +�. y tq d W N T > a •a a N ,p IS + O N c p N Om W � No.43409 $ 4s Q PRODUCT: D•cumenta Prepared By: y �� RGORIDP ' I� L ndonF. Schmidt - IN i o SINGLE HUNG WINDOW P.E. No. 43409 �i,�/ri8lDINA1.t����� 2 3 24 15 UPDATE.70 STH ED. 2014 FBC LFS PART OR ASSEMBLY: � BUILDING CONSULTANTS, INC. I� \ 1 9 9 1J REVISE ANCHORING ORWG. NO. JK P.O. Boz 230, VGlrieo, FL 33595 {' NO DATE BY HORIZONTAL & VERTICAL phone No.: 013.859.9197 EVI a RSIONS CROSS SECTIONS FBPE C.A. No. 9813 + ®2011 R.W.BUILDING DDN-AN'rS IN)p . 4" I I 6"MAX. {- -I �c •a Z c Z U) 24 �( J � U`��``` o0mZ TYP. a N� o Z U W/.2X BUCK 23 O a N g 9 p t a INSTALLATION ; i 'm a.a(° ri sU. . 2XBUCK W/1XBUCK 24 oz INSTALLATION g r� 2X BUCK "' TYP.HEAD, o a = JAMBS — FRAME yy/ BUCK 37 3 �NSTALLATION NSTALLATION 3 <MASONRY . W/1XBUCKj _ OPENING OPEONING TYP.JAMBS w N �¢ a 2 m z U N O O F w a a a a CS 2 a_ 3 �3 N m O Vl BUCKANCHORING FRAMEANCHORING W i g MASONRY N U K LL CONCRETE ANCHOR NOTES: Z 0 1.Concrete anchor locations at the corners may be adjusted to maintain the min. < • a w edge distance to mortarjoints. a o t; 2.Concrete anchor locations noted as"MAX.O.C.(TYP.j"must be adjusted to maintain the min.edge distance to morfarjoints,additional concrete anchors 8 may be required to ensure the'MAX.O.C.OYP.)"dimensions are not exceeded. ^w a 3.Concrete anchor table: ANCHOR NCNOR MfN MIN CLEARANCE, MIN CLEARANCE: "' i rypE SRE EMBEDMENT TO MASONRY TO ALTJACENi N^z °a .. ........ EDGE: ANCHOR ...:i a ITW we 10/24/11 3 TAPCON® 1/4" 1.1/4" 2" 4" o scau: N.T.S. 10 ELCO M.er: KV m ULTRACON® 1/4" 1-1/4" 1" 4" aK.BY: LFS 3 WOOD SCREW INSTALLATION NOTES: wuwwc 49 rc 1.Maintain a minimum 5/8"edge distance,1"end distance,&1"o.c.spacing of FL-111.13 N wood screws to prevent the splitting of wood. SHEET_L OF 4 yy 0 \\ ••• /i BILL OF MATERIALS G ' O ITEM DESCRIPTION MATERIAL 5/8"OVERALL ��. o xi n 1 EXTRUDED PVC MAIN FRAME#52-2611' PVC 30 1HK.GLASS 2 EXTRUDED PVC SILL#52-2613' PVC QO 1/9'ANNEALED Z 4:0z" om 3 EXTRUDED PVC GLAZING BEAD INTERLOCK #52-1257' PVC D ��' q�¢ N 4 EXTRUDED PVC MEETING RAIL#52-2907' PVC ///i� ........... >>°n°� 5 EXTRUDED PVC TOP RAIL#52-2908' PVC AIR SPACE ///�q�! I*1 ����\ o V)m z 6 EXTRUDED PVC BOTTOM LIFT RAIL#52-2949' PVC 7 EXTRUDED PVC STILE#52-2905' PVC 1/8 ANNEALED h' `- 0 u z z al 9 EXTRUDED PVC GLAZING BEAD VERT.&HORT. #52-1227• PVC 22 $`o a 9 6`o a 10 OPERABLE SASH LOCK - 1/7GLASS N n U) 11 SASH KEEPER STEEL BITE GlAZlNG DETAIL 0 z 12 FIXED MEETING RAIL REINFORCEMENT#51-2919 STEEL GT �a PP 14 LOCK RAIL REINFORCEMENT#51-2821 STEEL o 3 16 WINDOW SCREEN - 17 WEATHERSTRIP PILE W/FlN.187 x 270,LOCK RAIL&SASH ULTRAFAB - 0 18 1 WEATHERSTRIP PILE W/FlN.187 x.230,FIXED MEETING RAIL ULTRAFAB - 19 WEATHERSTRIP PILE W/FlN.187 x.150,SILL ULTRAFAB 3 N N o U W 0M 20 WEATHERSTRIP VINYL BULB.1 87'x.375'0 AMESBURY - 0.78' z z o 0 I �- -{— . 3 v 4 3 22 GLAZING COMPOUND DOW#1199 SILICONE 23 #10 X 7'PFH SMS STEEL '���+ L J 24 1/4"X 23/4"PFH ELCO OR ITW CONCRETE SCREW STEEL f--0.05 w 25 2X BUCK SG>=0.42 WOOD GLAZING BEAD GLAZING SEA 26 1/4"MAX.SHIM SPACE 3 D o n o J o Sash interlock 9 � LL MASONRY-3— -PSI MIN.CONCRETE CONFORMING TO ACI < m 27 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE a a 29 1 X BUCK SG>=0.42 WOOD J m 30 INTERCEPT SPACER STEEL 0.68"LL 37 #10 X 3"PPH SMS STEEL f� �I o 38 1/,V X 4"PFH ELCO OR ITW CONCRETE SCREW STEEL 0.79 o N .037 z •THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED 1 0.8" � �3 BY EXTRUDERS LICENSEES IN"AAMA CERTIFICATION PROGRAMS FOR RIGID PVC EXTRUSIONS". J- T- ^IF^-0.0s, n is v_s 0 0 T LOCK RAIL TOP LOCK MEETING RAIL EXTRUDED PVC GLAZING BEAD a12 Reinforcement 14 Reinforcement 9 o SN a Q U � 2.69" 269"—� z d in 1.16 o lz m o oo.91p"o "� 1.14' go 0.055" � L o h L 0.063'S/ L Ip Lo _00VJ�` 065" co Z o �OOO N � Q� ��� I u 0.065' wrE 10/24/11 z —[ sFwsc N.T.S. - 1 a DWG.ar: KV m T PVC MAIN FRAME .,PVC SILL 4 EXTRUDED PVC MEEiING RAIL 5 EXTRUDED PVC TOP RAIL r.1EXTRUDED PVC BOTTOM LIFT RAIL 7 EXTRUDED PVC STILE oHanwwc No.:LFS i FL-14911.13 0 N SHEET 4 OF 4 V I a