HomeMy WebLinkAboutMASTER FOUNDATION A1 (1)2"x2" GALVANIZED WASHER
WITH y" NUT
Y2' THREADED ROD
NOTCH OR COUNTERSINK BOLT
OPTIONAL FOR "HIGH SET"
THRU 2"x4" BOTTOM PLATE
1/2" THREADED ROD
T_
2"x2" GALVANIZED WASHER
1/2"x5" (400 LB) CONCRETE
OPTIONAL FOR "HIGH SET"
WITH 2 NUT
EYES BOLTED TOGETHER
WEDGE ANCHOR INTO SLAB
WITH Y"x2" BOLT & NUT WITH
Y2" COUPLER
THRU 2"x4" P.T. BOTTOM PLATE
1l2" COUPLER
(2) 2"x2" GALVANIZED WASHERS
=
(SEE TABLE 1 FOR SPACING)
2"x4" BOTTOM PLATE NAILED
U)
(2,000LB SHEAR CAPACITY)
^ 4" MIN.
TO 2"x6" P.T. BASE
w
a a
1/2"x12" FORGED EYEBOLT
Q
-
\/
y
a
4" MIN
>
�\
Yz"x 3" (400 LB)
CONCRETE WEDGE ANCHOR
-----�--
C NCRETE SLAB BY OTHERS ia-----_-_' - _- -
SIMPSON A-24 THROUGH LOCAL CODES
CONCRETE SLAB BY OTHERS
EYES BOLTED TOGETHER W/ 1/2"x2"
BOLT & NUT WITH (2)2"x2" GALVANIZED
GRADE
TYPE I, II, III, OR IV PAD WITH
(SEE TABLE 1 FOR SPACING)
CLIP OR EQUAL AND JURISDICTION
THROUGH LOCAL CODES
WASHERS (2,000LB SHEAR CAPACITY)
z
BLOCKING AS REQUIRE
AND JURISDICTION
(SEE TABLE 3)
30" EARTH AUGER ANCHOR
w
SHED WITH SKID
SHED WITH 'NO FLOOR' OPTION'
(SEE TABLE 4 FOR SPACING)
ANCHORED TO CONCRETE
ANCHORED TO CONCRETE
SHED WITH SKID
SETUP AND INSTALLATION OF SINGLE WIDE SHED
1. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR
MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE, PROPERTY LINE, ETC.
2. ONCE UNIT IS SQUARE AND THE HIGH SPOT OF THE GROUND IS ESTABLISHED, THE
BUILDING IS BLOCKED ON THE HIGH SPOT OF THE GROUND AND LEVELED. THE OTHER END OF THE
BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED. THEN THE CENTER OF THE BUILDING IS
SUPPORTED TO LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT
SPACING (SEE TABLE 3).
3. AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING
(SEE TABLE 3).
4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING, HOLES ARE DRILLED
THRU THE 2"X4" BOTTOM PLATE WITH A 1/2" AUGER BIT. 1/2" EYEBOLT OR OPTIONAL 1/2" THREADED
ROD (FOR A "HIGH SET") IS SECURED THRU THE HOLE.
5. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO
FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS.
6. IF THE UNIT HAS A FLOOR, EITHER A HOLE IS DUG FOR THE 30" AUGER ANCHOR AND
BACKFILLED AND SECURED AS PER THE DETAIL OR A 1/2" HOLE IS DRILLED INTO THE CONCRETE
1-1/2" OFF THE RIM JOIST. THE EYEBOLT IS FASTENED THRU THE BOTTOM PLATE AND A SIMPSON
A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2" WEDGE ANCHOR.
7. IF THE UNIT A'NO FLOOR' OPTION, ANCHOR WITH 1/2"X5" WEDGE ANCHOR THRU THE 2"x4" BOTTOM
PLATE.
TABLE 1
ANCHORING TO CONCRETE
SHED WIDTH
UPLIFT (PLF)
ANCHOR SPAC'G
20'-0"
400
3'-6"
13'-8"
280
3'-6"
11'-8"
240
3'-6"
10'-0"
200
3'-6"
8'-0"
160
3'-6"
6'-0"
120
3'-6"
TO PAD OR BLOCKING
SETUP AND INSTALLATION OF DOUBLE WIDE SHED
1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS
PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP.
2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL. ONCE THE
BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3).
3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE
FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1) �,X#,
BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE
LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS
PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE.
4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B).
5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS
REMOVED.
6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO
FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS.
TABLE 2
SKID RUNNER SPACING*
SHED WIDTH
X1
X2
X3
13'-8"
1'-101,21.,
1'-1q,
1'-10?"
11'-8"
2'-8"
64"
10'4"
V-7"
6'-10"
8'-0"
91,
6'-6"
6'-0"
10"
51"
* VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4"X4"
NOTES:
1. HOLLOW OR SOLID CONCRETE BLOCKS (8"x8"x16") MAY BE
STACKED ON PADS FOR HIGH SETS UP TO 48" WITHOUT
REINFORCING.
2. ABS PADS REQUIRED ON 1 V-8" AND 13'-8" WIDE SHEDS ONLY.
TABLE 3A
PAD TYPES
TYPE
PAD DIMS
MAX LOAD*
MATERIAL
I
2"x8"X16"
1778 LBS
N . BL K QUALITY
CEMENT AND SAND MIX
11
4"x8"X16"
3500 LBS
_UUN . BL K QUALITY
CEMENT AND SAND MIX
III
16"X16"
3950 LBS
ABS PLASTIC PADS
IV
8"X8"X16"
1 1900 LBS
CONIC. BLOCK QUALITY
CEMENT AND SAND MIX
* BASED ON 2000 PSF SOIL BEARING CAPACITY (2000 PSF IS TYPICAL)
NOTES:
1. HOLLOW OR SOLID CONCRETE BLOCKS (8"x8"x16") MAY BE STACKED
ON PADS FOR HIGH SETS UP TO 48" WITHOUT REINFORCING.
2. ABS PADS REQUIRED ON 1 V-8" AND 13'-8" WIDE SHEDS ONLY.
TABLE 3
SUPPORT FOOTING PAD SPACING FOR RUNNER BLOCKING FOR SINGLE & DOUBLE WIDE SHEDS
SHED DESCRIPTION
PAD
MAXIMUM LOAD AND PAD TYPE
SHED WIDTH
TYPE
LW* (PLF)
END PAD
MAX. SPACING
END PAD
SIDE RUNNER
PAD TYPE
INTERIOR
PAD
SIDE RUNNER
PAD TYPE
13'-8"
SW/DW
4.15/332
0" TO 6"
6-0"
1936 LB
I, II, III, OR IV
1879LB
I, II, III, OR IV
1 V-8"
SW/DW
6.00/480
0" TO 6"
6'-0"
2558 LB
I, II, III, OR IV
2558LB
I, II, III, OR IV
10'-0"
SW/DW
5.00/400
0" TO 6"
6'-0"
2400 LB
I, II, III, OR IV
2400LB
I, II, III, OR IV
8'-0"
SW
4.00/320
0" TO 6"
6'-0"
2029 LB
I, II, III, OR IV
2133LB
I, II, III, OR IV
6'-0"
SW
3.00/240
0" TO 6"
6'-0"
1658 LB
1 I, II, III, OR IV
1866LB
1 I, II, III, OR IV
* LOAD WIDTH OF UPLIFT ON RUNNER
NOTES:
1. PAD SPACING IS END TO CENTER OF PAD
2. PADS OTHER THAN END PADS SPACING IS CENTER TO CENTER
3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING
30" AUGER ANCHOR
(4,725 LB)
INSTALLED PER MFRS
INSTRUCTIONS. EYELET AT
MAXIMUM OF 6" ABOVE GRADE
CODE INFORMATION
CODE VERSION
FBC, 7TH EDITION
(2020), ASCE-7-16
MANUFACTURER
SUPERIOR SHEDS
BUILDING TYPE
MANUF. SHED
CONSTRUCTION
V-B
CODE VERSION
NONE
FIRE SUPPRESSION SYSTEM
NONE
OCCUPANCY
STORAGE
ALLOWABLE NO. OF STORIES
1
BASIC WIND SPEED
180 MPH (VULT)
EXPOSURE
C
ENCLOSURE
ENCLOSED
INTERNAL PRESSURE COEF.
+/- 0.18
IMPORTANCE FACTOR
1.15
ROOF DEAD LOAD
10 PSF
ROOF LIVE LOAD
20 PSF OR 300LBS
FLOOR DEAD LOAD
8 PSF
FLOOR LIVE LOAD
75 PSF / 125 PSF
"R" RATING (WALL, FLOOR, ROOF)
N/A
MODULES PER BUILDING
1
HURRICANE PROTECTION USAGE
NO
HURRICANE SHELTER USAGE
NO
SQUARE FOOTAGE
LESS THAN 720 S.F.
MODULAR
PT. AN.q TIF.RT(tN CC)
GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS
1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP-1 SINGLE HELIX EYE
AUGER ANCHORS BY HOME PRIDE OF BRISTOL, VA. OR EQUIVALENT. AVERAGE
HOLDING STRENGTH IS NOT LESS THAN 4,725 LBS.
2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER).
LOCATE ANCHORS PER TABLE 4A OR 4B.
3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE
(FLOOR SYSTEM) AND ATTACHED TO ANCHOR. THESE CAN BE EXTENDED WITH
THREADED ROD (OR STRAPS WITH EQUAL OR GREATER STRENGTH) FOR
ELEVATED PORTIONS OF SHEDS ON LEVELING BLOCKS.
TABLE 4A
30" AUGER ANCHOR SPACING - SINGLE WIDE
SHED WIDTH
LW*
UPLIFT (PLF)
END ANCHOR**
MAX. INTERIOR SPACING**
13'-8"
7.00
243
0'-0" TO 3'-0"
10'-0"
1 V-8"
6.00
208
0'-0" TO 3'-0"
10'-0"
10'-0"
5.00
174
0'-0" TO 3'-0"
10'-0"
8'-0"
4.00
138
0'-0" TO 3'-0"
10'-0"
6'-0"
3.00
104
0'-0" TO X-O"
10'4"
TABLE 4B
30" AUGER ANCHOR SPACING - DOUBLE WIDE
SHED WIDTH LW* UPLIFT (PLF) END ANCHOR** MAX. INTERIOR SPACING**
20'-0" 10.00 1 400 1 0'-0" TO 3'-0" 1 5'-0"
* LOAD WIDTH UPLIFT ON RUNNER
** LOCATION FROM END WALL OF AUGER ANCHOR
*** MAXIMUM SPACING BETWEEN ANCHORS
NOTES
1. ANCHOR SPACING IS DESIGNED AS PER ASCE-7
2. ALL MEASUREMENTS ARE CENTER -TO -CENTER
3. THE MINIMUM NUMBER F ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER.
ADDITIONAL INTERIOR ANCHORS ARE REQUIRED IF SPACING IS MORE THAN 10'-0"
BETWEEN ANCHORS.
4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO AN
EXISTING BUILDING: IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE
TO THE SIDE AS POSSIBLE.
GENERAL NOTES:
1. FOUNDATION PLANS ARE NOT PART OF THIS
PLAN SET AND ARE GOVERNED BY LOCAL
JURISDICTION.
2. THIS BUILDING IS EXEMPT FROM THE FBC
ENERGY CONSERVATION CODE PER SECTION
1015.22
3. REFER TO TIE -DOWN DETAILS FOR PROPER
INSTALLATION REQUIREMENTS TO MEET CODE.
MODULAR PLANS DESIGN, CO.
202 DORIS DRIVE., SUITE 105 OFFICE: 863.688.1054
LAKELAND, FLORIDA FAX: 863.688.7118
33813 COLE@MODULARPLANSCO.COM
,,",0 ORS,
?
N". 38]89
%Ap s T] or
:Fcoam@i' \2
' �SS�ONAL ECG\
Digitally signed by
Julio Orbegoso
Date: 2021.02.01
16:42:51-05'00'
CONSULTING ENGINEER
JULIO ORBEGOSO
FLORIDA
PE LICENSE #38769