Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MURPHY RESIDENCE Builder Name: Street: OAK DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE , FL, Permit Number. Owner: KEVIN AND TERRI MURPHY Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce . County. St Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2411.7 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul. Exterior R=5.0 2035.70 ft' b. Frame- Wood, Adjacent R=11.0 376.00It' 3. Number of units, if multiple family 1 c. NIA R= g2 4. Number of Bedrooms 3 d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types (2232.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 2232.0D ft 6. Conditioned floor area above grade (ft') 2232 b. N/A R= W Conditioned floor area below grade (ft) 0 c. NIA R= fo 11. Ducts R W 7. Windows (341.8 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 200 a. U-Factor: Sgl, U=0.66 341.75 ft' SHGC: SHGC=0.25 b. U-Factor. NIA ft' 12. Cooling systems kBtu1hr Efficiency SHGC: a. Central Unit 46.5 SEER:16.00 c. U-Factor. N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. NIA ft' a_ Electric Strip Heat 34.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 4.502 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2232.0 sgft.) Insulation Area EF: 0 980 a. Slab -On -Grade Edge Insulation R=0.0 2232.00 ft' 9 b. Conservation features b. N/A R= ft' None c. N/A R= ft' 15. Credits None Glass/Floor Area: 0.153 Total Proposed Modified Loads: 73.25 PASS Total Baseline Loads: 76.91 1 hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Review of the plans and specifications covered by thisti�= 4,'[HE ST,11 £O Code. calculation indicates compliance with the Florida Energy Code. r �k , u O PREP RED - DATE: Y: 4_93� Before construction is completed this building will be inspected for compliance with Section 553-908 ° � 1 hereby certify that this , as designed, is in compliance Florida Statutes. ._ tg"� •. with the Florida rgy de ADD �� L� OWNER/AG T BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402A.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402A.1.2). FILE COPY 10/15/202011:08 AM EnergyGauge@) USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: MURPHY RESIDENCE Builder Name: Street: OAK DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE , FL, Permit Number: Y Owner: KEVIN AND TERRI MURPHY Jurisdiction: ST LUCIE COUNTY w= Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an J plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind oloinci and wirin . Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. t Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 10/15/202011:09 AM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 46.5 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2232 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.660 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 34.0 c) Area 7c. 341.8 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 5.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 ` b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which w'll.Fa in a (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be mpl bas on ' d code compliant features. Builder Si natu . Date: 161 Z> I W Address of New Home: OAK DRIVE City/FL Zip: PORT ST LUCIE, FL 10/15/2020 11:09:09 AM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: MURPHY RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2232 Lot # Owner Name: KEVIN AND TERRI MURPHY Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: OAK DRIVE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: PORT ST LUCIE, Family Type: Single-family FL, New/E)asting: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2232 2-2503.9 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 345 3553.5 No 0 1 1 Yes Yes Yes 2 M BATH 102 948.6 No 0 1 Yes Yes Yes 3 M W IC 1 45 418.5 No 0 1 Yes Yes Yes 4 M TOILET 28 260.4 No 0 1 No Yes Yes 5 POWDER RM 32 297.6 No 0 1 No Yes Yes 6 M HALL 47 437.1 No 0 1 No Yes Yes 7 FOYER 164 1968 No 0 1 Yes Yes Yes 8 WIC 2 24 223.2 No 0 1 No Yes Yes 9 HALLWAY 52 483.6 No 0 1 Yes Yes Yes 10 BEDROOM 3 230 2139 No 0 1 1 Yes Yes Yes 11 CLST 3 28 260.4 No 0 1 Yes Yes Yes 12 BATH 3 65 604.5 No 0 1 Yes Yes Yes 13 BATH 2 65 605 No 0 1 Yes Yes Yes 14 BEDROOM 2 182 1692.6 No 0 1 1 Yes Yes Yes 15 LINEN 6 55.8 No 0 1 No Yes Yes 16 HALL 12 111.6 No 0 1 No Yes Yes 17 LAUNDRY RM 72 669.6 No 0 1 Yes Yes Yes 18 PANTRY 20 186 No 0 1 Yes Yes Yes 19 KITCHEN/DINING 313 2910.9 Yes 0 1 Yes Yes Yes 20 LIVING ROOM 355 4260 No 0 1 Yes Yes Yes 21 M WIC 2 45 418.5 No 0 0 1 Yes Yes Yes 10/15/202011:08 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 45 ft 0 345 ft2 --__ 1 0 0 2 Slab -On -Grade Edge Insulation M BATH 12 ft 0 102 ft2 -___ 1 0 0 3 Slab -On -Grade Edge Insulation M W IC 1 6 ft 0 45 ft2 ---_ 1 0 0 4 Slab -On -Grade Edge Insulation M TOILET 1 ft 0 28 ft2 ---- 1 0 0 5 Slab -On -Grade Edge Insulation POWDER RM 1 ft 0 32 ft2 --__ 1 0 0 6 Slab -On -Grade Edge Insulation M HALL 1 ft 0 47 ft2 ____ 1 0 0 7 Slab -On -Grade Edge Insulation FOYER 8 ft 0 164 ft2 1 0 0 8 Slab -On -Grade Edge Insulation WIC 2 1 ft 0 24 ft2 -_-- 1 0 0 9 Slab -On -Grade Edge Insulation HALLWAY 6 ft 0 52 ft2 _-__ 1 0 0 10SIab-On-Grade Edge Insulation BEDROOM 3 34 ft 0 230 W ---- 1 0 0 11SIab-On-Grade Edge Insulation CLST 3 16 ft 0 28 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation BATH 3 5 ft 0 65 ft2 -___ 1 0 0 13SIab-On-Grade Edge Insulation BATH 2 5 ft 0 65 ft2 _ __ 1 0 0 14SIab-On-Grade Edge Insulation BEDROOM 2 14 ft 0 182 ft2 ---- 1 0 0 15SIab-On-Grade Edge Insulation LINEN 1 ft 0 6 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulation HALL 1 ft 0 12 ft2 ---_ 1 0 0 17SIab-On-Grade Edge Insulation LAUNDRY RM 6 ft 0 72 ft2 ---_ 1 0 0 18SIab-On-Grade Edge Insulation PANTRY 4 ft 0 20 ft2 _--_ 1 0 0 19SIab-On-Grade Edge Insulation KITCHEN/DININ 57.2 ft 0 313 ft2 __-_ 1 0 0 20SIab-On-Grade Edge Insulation LIVING ROOM 14 It 0 355 ft2 -_-- 1 0 0 21SIab-On-Grade Edge Insulation M W IC 2 6 ft 0 45 ft2 --__ 1 0 0 ROOF V Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor, Tested Tested Insul. (deg) 1 Hip Barrel file 2418 ft2 0 ft2 Medium N 0.4 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2232 ft2 N N 10/15/202011:08 AM EnergyGaugeO USA 6.0,02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 345 ft2 0.1 Wood 2 Under Attic (Vented) M BATH 30 Blown 102 ft2 0.1 Wood 3 Under Attic (Vented) M WIC 1 30 Blown 45 ft2 0.1 Wood 4 Under Attic (Vented) M TOILET 30 Blown 28 ft2 0.1 Wood 5 Under Attic (Vented) POWDER RM 30 Blown 32 ft2 0.1 Wood 6 Under Attic (Vented) M HALL 30 Blown 47 ft2 0.1 Wood 7 Under Attic (Vented) FOYER 30 Blown 164 ft2 0.1 Wood 8 Under Attic'(Vented) WIC 2 30 Blown 24 ft2 0.1 Wood 9 Under Attic (Vented) HALLWAY 30 Blown 52ft2 0.1 Wood 10 Under Attic (Vented) BEDROOM 3 30 Blown 230 ft2 0.1 Wood 11 Under Attic (Vented) CLST 3 30 Blown 28 ft2 0.1 Wood 12 Under Attic (Vented) BATH 3 30 Blown 65 ft2 0.1 Wood 13 Under Attic (Vented) BATH 2 30 Blown 65 ft2 0.1 Wood 14 Under Attic (Vented) BEDROOM 2 30 Blown 182 ft2 0.1 Wood 15 Under Attic (Vented) LINEN 30 Blown 6 ft2 0.1 Wood 16 Under Attic (Vented) HALL 30 Blown 12 ft2 0.1 Wood 17 Under Attic (Vented) LAUNDRY RM 30 Blown 72 ft2 0.1 Wood 18 Under Attic (Vented) PANTRY 30 Blown 20 ft2 0.1 Wood 19 Under Attic (Vented) KITCHEN/DININ 30 Blown 313 ft2 0.1 Wood 20 Under Attic (Vented) LIVING ROOM 30 Blown 355 ft2 0.1 Wood 21 Under Attic (Vented) M WIC 2 30 Blown 45 ft2 0.11 Wood WALLS Adjacent Space Cavity R-%/811 le Width Ft In Height Et In Area Sheathing Framing R-Vall le Erantonn Solar AhSor Below 0 1 N Exterior Concrete Block - Int InsuMASTER BE 5 18 0 10 4 186.0 ft2 0 0 0.4 0 2 S Exterior Concrete Block - Int InsuMASTER BE 5 11 0 10 4 113.7 ft2 0 0 0.4 0 3 W Exterior Concrete Block - Int InsuMASTER BE 5 16 0 1.0 4 165.3 ft2 0 0 0.4 0 4 N Exterior Concrete Block - Int Insul M BATH 5 6 0 9 4 56.0 ft2 0 0 0.4 0 5 N Exterior Concrete Block- Int Insul M W IC 1 5 9 0 9 4 84.0 ft2 0 0 0.4 0 _ 6 E Garage Frame - Wood M TOILET 11 7 0 9 4 65.3 ft2 0 0.1 0.4 0 7 E Garage Frame - Wood POWDER R 11 8 0 9 4 74.7 ft2 0 0.1 0.4 0 8 E Exterior Concrete Block - Int Insul FOYER 5 8 0 12 0 96.0 ft2 0 0 0.4 0 9 N Garage Frame - Wood FOYER 11 15 0 12 0 180.0 ft2 0 0.1 0.4 0 10 N Exterior Concrete Block - Int Insul HALLWAY 5 6 0 9 4 56.0 ft2 0 0 0.4 0 _ 11 N Exterior Concrete Block - Int InsuBEDROOM 3 5 19 0 9 4 177.3 ft2 0 0 0.4 0 12 E Exterior Concrete Block - Int InsuBEDROOM 3 5 15 0 9 4 140.0 ft2 0 0 0.4 0 13 E Exterior Concrete Block - Int Insul CLST 3 5 2 0 9 4 18.7 ft2 0 0 0.4 0 14 S Exterior Concrete Block - Int Insul CLST 3 5 14 0 9 4 130.7 ft2 0 0 0.4 0 15 S Exterior Concrete Block - Int Insul BATH 3 5 5 0 9 4 46.7 ft2 0 0 0.4 0 16 S Exterior Concrete Block - Int Insul BATH 2 5 5 0 9 4 46.7 ft2 0 0 0.4 0 17 S Exterior Concrete Block - Int InsuBEDROOM 2 5 14 0 9 4 130.7 ft2 0 0 0.4 0 18 S Exterior Concrete Block - Int InsuLAUNDRY R 5 6 0 9 4 56.0 ft2 0 0 0.4 0 _ 19 S Exterior Concrete Block - Int Insul PANTRY 5 4 0 9 4 37.3 ft2 0 0 0.4 0 10/15/202011:08 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent To Wall lypeSpace Cavity , Width Height Sheathing Framing Solar Below 20 E Garage Frame - Wood M BATH 11 6 0 9 4 56.0 ft2 0 0.1 0.4 0 _ 21 S Exterior Concrete Block - Int InsuKITCHEN/DI 5 18 0 9 4 168.0 ft2 0 0 0.4 0 22 W Exterior Concrete Block - Int InsuKITCHEN/DI 5 13 0 9 4 121.3 ft2 0 0 0.4 0 23 W Exterior Concrete Block - Int InsuLIVING ROO 5 14 0 12 0 168.0 ft2 01 0 0.4 0 24 N Exterior Concrete Block - Int Insul M TOILET 5 4 0 9 4 37.3 ft2 0 0 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated FOYER None .39 3 8 24 ft2 2 N Insulated FOYER None .39 2 6 6 8 16.7 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes 0.66 0.25 N 20.0 ft2 1 ft 6 in 1 ft 4 in None None 2 W 3 Metal Low-E Single Yes 0.66 0.25 N 48.0 ft2 1 ft 6 in 1 ft 4 in None None 3 E 8 Metal Low-E Single Yes 0.66 0.25 N 16.0 ft2 10 ft 6 in 1 ft 4 in None None 4 E 12 Metal Low-E Single Yes 0.66 0.25 N 45.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 5 S 15 Metal Low-E Single Yes 0.66 0.25 N 5.8 ft2 1 ft 6 in 1 ft 4 in None None 6 S 16 Metal Low-E Single Yes 0.66 0.25 N 6.0 ft2 1 ft 6 in 1 ft 4 in None None 7 S 17 Metal Low-E Single Yes 0.66 0.25 N 30.0 ft2 1 ft 6 in 1 ft 4 in None None 8 S 18 Metal Low-E Single Yes 0.66 0.25 N 9.0 ft2 1 ft 6 in 1 ft 4 in None None 9 W 22 Metal Low-E Single Yes 0.66 0.25 N 72.0 ft2 1 ft 6 in 1 ft 4 in None None 10 W 23 Metal Low-E Single Yes 0.66 0.25 N 72.0 112 12 ft 6 in 1 ft 4 in None None 11 E 8 Metal Low-E Single Yes 0.66 0.25 N 10.0 ft2 10 ft 6 in 1 ft 4 in None None 12 N 4 Metal Low-E Single Yes 0.66 0.25 N 8.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 500 ft2 500 ft2 36 ft 10 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000448 2625.5 144.14 271.07 .1705 7 10/15/2020 11:08 AM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 46.5 kBtu/hr 1395 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply ---- V ---- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 200 ft2 Attic 20 ft2 Default Leakage Attic (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: ling an Feb Mar Venting J� Jan Feb �X Mar Apr Apr ay Jul M Jun May Aug Sep �A Oct Nov Dec Jun [ Jul l [ Aug l [ Sep t Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (W EH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 TOILET RM Default(8 Ibs/sq.ft, ft2 ft 0.3 LAUNDRY RM Default(8 Ibs/sq.ft. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft, ft2 ft 0.3 ENTRY WAY Default(8lbs/sq.ft. ft2 ft 0.3 KITCHEN/DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 LINEN Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL 10/15/2020 11:08 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 lbs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 STUDY CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 STUDY Default(8lbs/sq.ft. ft2 ft 0.3 GREAT RM Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC Default(8 Ibs/s .ft. ft2 ft 0.3 MASTER BEDROO 10/15/202011:08 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7