HomeMy WebLinkAboutProduct Review; Smart Vent(JC ��0^To�jV
INSTALLATION INSTRUCTIONS
Smart VENT &DETAILS
MODEL 1540-520
FLOODVENT INSULATED
aw "As
877— 441— 8368
www.smartvent.com
1. REMOVE VENT DOOR FROM VENT FRAME. (TURN UPSIDE DOWN, ROTATE BOTTOM OF DOOR OUTWARD AND SLIDE OUT)
2. PREPARE A CLEAN 16.25" WIDE BY 8.25" HIGH ROUGH OPENING (APPROX. 1 BLOCK WIDE X 1 BLOCK HIGH) FOR EACH VENT. ENSURE THE BOTTOM OF THE ROUGH OPENING IS NO MORE
THAN 12" ABOVE THE FINISHED GRADE.
3. APPLY A BEAD OF HURRIBOND GRIP & SEAL OR EQUIVALENT ADHESIVE AROUND THE BACK OF THE FLANGE ON THE VENT FRAME. (FIG. 2)
4. INSERT INSTALLATION CUPS INTO THE TWO SLOTS ON THE TOP AND TWO SLOTS ON THE BOTTOM OF THE FRAME.
5. THE SPRING ARM OF THE CLIPS SHOULD BE ON THE OUTSIDE OF THE VENT FRAME.
COMPRESS THE BOTTOM TWO CUPS AND BEGIN SLIPPING THE FRAME INTO THE OPENING. ENSURE THAT THE BOTTOM CUPS ARE IN THE OPENING BEFORE ALLOW THEM TO DECOMPRESS.
6. WITH THE FRAME NOW IN THE OPENING, AND THE BOTTOM SPRINGS IN PLACE, COMPRESS THE TOP SPRINGS AND PUSH THE VENT FRAME INTO THE OPENING
COMPLETELY UNTIL THE FRAME IS FLUSH WITH THE WALL
7. RE -CHECK THAT FRAME IS SQUARE AND SLOTS ARE CLEAR OF DEBRIS, AND CAULK.
8. INSTALL THE DOOR INTO FRAME BY GRASPING THE BOTTOM OF DOOR (WITH FLOAT PINS DOWN) AND FRONT (SMALL SCREEN IN FRONT). SLIDE DOOR INTO FRAME AND
ROTATE UNTIL IT IS LATCHED.
9. TO OPEN THE DOOR INSERT TWO CREDIT CARDS INTO THE FLOAT SLOTS AS SHOWN IN THE DIAGRAM. THIS WILL UNLATCH THE DOOR FOR REMOVAL AND CLEANING.
on
wow
&OUVAIL SPECIFICATIONS:
%MATERIAU STAINLESS STEEL
GERATION: AUTOMATIC NON -POWERED ACTIVATION AND OPERATION
�0 ALLATION:
SECURED W/ 4 STAINLESS STEEL INSTALLATION CLIPS INCLUDED AND AN ADHESIVE
OSTATIC RELIEF: 200 SQ. FT PER VENT
REQUIREMENTS: MINIMUM OF 2 VENTS PER ENCLOSED AREA MOUNTED ON AT LEAST TWO DIFFERENT WALLS
COLORS: STAINLESS (STANDARD)
EXTERIOR POWDER COATED WHITE, WHEAT, GRAY, AND BLACK (AVAILABLE)
MEETS THE REQUIREMENTS FOR ENGINEERED OPENINGS AS SET FORTH BY:
FEMA, NFIP, ICC, & ASCE
SUPPORTIVE DOCUMENTS, TB 1-08. 44CFR 60.3(C)(5), ASCE 24-14
[CC EVALUATION # ESR-2074
SHEET 2 OF 2
r
FIGURE 2
SIDE VIEW
Al
8 1/4-
R/O
GRIP & SEAL
ACATION
_----CUPS INSTALLED: TWO ON
o TOP TWO ON BOTTOM
DETAIL DIAGRAM
MODEL 1540-520
FLOOD VENT INSULATED
16 1/4- R/O
FLOAT SLOTS —�
FIGUF
FRONT
CUP SLOTS USE TWO TOP
AND TWO BOTTOM
SMART VENT®
77-441-8368
WWW.SMARTVEKr.COM
SMAKI VENT FOUNDATION FLOOD VENTS
430PITMAN NJ 09071�� 1
FLOOD VENT INSULATED
MODEL 1540-520
sA� DMIG No. iy
� 1540-520 e
DATE 6-21-18 SiEETET 1 OF 2
SMART VENT
Foundation FloodVents
INS'U'LATED ERIES -
This series of vents is ideal for areas requiring
flood venting protection but no natural
air ventilation.
The flood door contains a 2" 'insulated core that �
has an R-value of 0:34 and the. ventframe- is lined .
with felt Weather stripping,, helping. to keep the. -
enclosure as insulated from the elements as possible.
IDEAL FOR:
Garages
• Full height enclosures (e.g. walkouts)
• Conditioned crawlspaces ,
Storage facilities
.s
Metal buildings
• Foyers
0 Flood Vent
1540-520
Stacker
1540-521
Stacker Models are twice as efficient
as a single unit and -are a great solution
for large amounts of square footage,
and in situations where there is
not enough wall space to fit in
single .units.
Wood Wall
1540-570
Wood Wall Models are designed to fit
between studs spaced at 16" on center.
Pre -drilled slots in the four corners -on
the vent flange°make for an
easy installation.
f
i
{�4 ' P Ow
y }
Piefured in
For more information on Flood Protection- Solutions,, contact:
Smart Vent 430 Andbro Drive, Unit 1Pitman, NJ08071
Website; www.smartvent.com Tel; (877) 441-8368• Email:-info@smartvent.com