HomeMy WebLinkAboutReviewed Floor Planm..d of Ns robe, at bottom of lintel ro R, grout I .� wiMA G.M. 6 8F16-1 B/1 T cenforced g'Nom ml ..icret. T T xs rob.,.t bottom � .J '.ft'eroJ of fetid c.ft hwle Lintel Type Designation Safe Load Table Notes 1. All values based on minimum 4- nominal bearing. Exception: Safe loads for unfilled U lintels must be reduced by 20% if bearing length is less than 6 1 /2". 2. N.R. = Not Rated 3. Safe loads are superimposed allowable loads. 4. One #7 rebar may be substituted for two #5 rebar in 8 inch U lintels only. 5. All safe loads in units of pounds per tinier foot. 6. All safe loads are based on simply supported span. 7. Safe load ratings based on rational design analysis per ACI 318 and ACI 530. Composite U Lintel Materials 1. Grout per ASTM C476 fg=3000 psi with maximum 3/8 inch aggregate and 8 to 11 inch slump. 2. Rebar per ASTM A615 Grade 60 3. Concrete masonry units (CMU) per ASTM C90 with minimum net area compressive strength = 1900 psi 4. Mortar per ASTM C270 Type M or S Installation Notes 1. Installation of U lintels must comply with architectural and/or structural drawings. 2. U lintels can be field cut to the required length. 3. Cast in place concrete may be provided in composite U lintel in lieu of concrete masonry units. 4. The exterior surface of U lintels installed in exterior concrete masonry walls shall have a'coating of stucco applied in accordance with ASTM 0-926 or other approved coating. 5. Concrete masonry units used in composite U lintel sha11 be laid in a running bond. 6. Shore composite lintels as required. 7. U lintels are manufactured with a 5 1/2" long notch at both ends to accomodate vertical cell reinforcing and grout. Cast in place sill or Tie Beam Option In the event that precast products are damaged in the field cast in place sills and tie beams may be used (not to exceed 5'-10") Typical cast in place tie beam to be a min. 8" x 12" with (2) #5 top and (2) #5 bottom c Bottom Cord of Truss o 1 1/ p plate gyp. d.w. ids 24"o.c. :ud Grade p.t. sill plate base id Hard Coil 12"o.c. max. r Concrete Foundation Interior Wall Section Non Load Brng. Cast Crete Lintel Schedule All Reber to v vv I Climatic & Geographic Desi n Criteria 5 Grade 60 min.g MARK LENGTH OF LINTEL ALLOWABLE GRAVITY LOAD APPLIED GRAVITY LOAD ALLOWABLE UPLIFT LOAD APPLIED UPLIFT OAD BEAM SPECS L-1 T-8" 8974 241 4853 9 8F24-1B/1T L-2 4'-6" 8672 788 4292 24 8F24-1B/1T L-3 4'-2" 8672 241 4292 90 8F24-1B/1T L-4 T-10" 8974 241 4853 90 8F24-1B/1T L-5 6'-9" 5681 250 2571 1 0 8F24-1B/1T L-6 T-2" 5681 98 2571 7� 8F24-1B/1T L-7 T-0" 11809 250 7636 150 8F48-1B/fT L-8 17'-4" 2047 454 872 14,3 8F40-1B/1T L-9 4'-8" 9311 241 4594 9 8RF42-1B/1T L-10 5'-4" 7342 204 3607 83 8F24-1B/1T L-11 T-8" 5891 888 2322 2 3 8RF30-1B/IT L-13 10'-4" 1533 250 914 1 0 8F16-1B/1T L-14 13'-6" 1002 250 559 1 0 8F16-IB/IT L-15 10'-8" 1366 488 798 3 4 8F16-1B/tT L-16 14'-7" 1370 163 519 1 2 j 8F16-1B/1? L ART VENT Weathering: Negligible Termite Area: Very Heavy ation Flood Vents e Area:517 sq. ft. Flame Spread Index & Smoke Developed Index Number: 1540-520 Coverage: 200 sq. ft. Insulation Flame Spread: Not to exceed 25 ntilation: 51 sq. in. Insulation Smoke Developed index: Not to exceed 450 ize: 16"" x 8"" x 3"" Opening: 16 1 /4"" x 8 1/4"" Wall Finishes: Not greater than 200 ) vents (600 s.f. provided) Ceiling Finishes: Not greater than 200 oor plan for locations ttom of vent within 12"" Wall Key garage finished floor Load Brng. Frame Frame Walls 0 (Non Lead Brrg.) Project Data Design Loads Area Tabulation Project Name: Kevin Murphy Roof Live Load: 30.0 p.s.f. Living: 2232 Street Address: XXXX Oak Drive Wind Speed: 16D MPH Garage: 517 City: Ft. Pierce Wind Importance Factor: 1.0 County: St. Lucie Building Category: 11 Porch: 291 State: Florida Wind Exposure: B Entry: 61 Internal Pressure Coefficent:.18 Scope of Work Structure Designed: Enclosed Total 3101 Soil bearing capacity: 2000 p.s.f. New One level CBS Single Family residence Building Data Total Cubic Volume: 21,844 c.f. Building Code Occupancy Type:- Group R Construction Type: V 2017 Florida Building Code: Residential Number of Stories: One 2014 National Electrical Code: NFPA 70 Project Area: M1 s.f. L-10 5og L-9 ° Flood Vents H35 Septic L-1 Stub Out (-`1 H35 48"'x 24" Fixed Glass Transom tvh (3) places at Hatched i s.h. s.h, d C1 C7 O Areas M I!] Eli M M — -- — — — -- 'M s 0 m LOAD 1 I I L-11 Master Bdrm. `r I co BRNG.bo WALLS U') 1 _ i p I 9'- 1 'Coffer �17'-0" 2668 Temp. Glass on 48"Tall 2'-6" A.H.U: I ❑ 8" I 8'-9" Pocket Wall in atti& 6068ch c 2668 Pocket 6'-0' 14 2'-5" 19'-8' 3'-0`" 18'-0" , _.- I Q 2668 N Ccna Pad 118" Pocket v I _ t i Attic Access I ❑ I with Ladder :..0 J Garage �` HB L — — — — — — M Cing. 9'-4"Ceiling o' I co 2668 from F.F.E. o C7 Storage Truss Above 1 U. C] O O 2668 aio ❑' `�' "' j C] 31_4 6 i Cono. Steps R11 Batt Insul. 3" Irl 1 j ❑. - 0Adj. LOAD, in Walls 1 _—__ Hdr. L-] l Porch 1 a at 8,-0" 2 z i2 Neader WALLS p — p p e I I Sloped Ceiling L 14 g I l L-13 Living 17" ° o0 3080 Dr. & (2) F. E. co co L-16 I I from 9'-4""FFE Stucco Ceiling g 19080 I PKT 12'-0" Ceiling to N e 12"Temp. Side 12'-0" Ceiling Lites Transom 12'-0" Cln g L-6 I I S.G.D. a 64, Above from F.F.E. ° o IT-4" 4'-0" 6'-6- 6'-10- 4'-0" 2" 5'-4- 1'-8- 16" Frame out Lintel Pn 1 8' 3'-6' 2'-4' EGRESS I 3'"I to match width of columns ng I I L-5 Ceiling 1 I Brng. Clmn. RIME] ----- C7 Rl O FEIM R7 ❑p p p I 0 0cc---- R1 Exp. Joint C1 C] T 2668 N I ---- - M Cing. Q Fol 5'-4" 10'-0` C) 6'-0, 2068 2668 �� 2868 °L� ?ps8 Bdrm. 3 26 s.h. Egress O Rl I I 1 �° Pocket Pocket 0 I I I Limits of 12' 0" Cing. c L w i ih 9-4" Ceiling 1 v L-16 I1 1 = — — — — — — — —1 � 1'-9' 4'-, I N 3•• I 6'-0`" F1110 6" ,a in 13'-4" 2668 Pocket 3'-4" 2'-0"" 2'-0"' 3'-4" 12'-10" � 26 s.h. Egress o ih cc ILI] o L-4 1 9080 9'-4"' 1 .Q�0 I PKT: I S.G,D. I Cing. N Bdrm. 2 p T eat ��/ Lr14 L-1,3 Kitchen ? 1 9'-4" Ceiling Q 2'-6"` O 26 s.h. Egress 1 o Sloped Ceiling g B L_3 ICI ' i co from 9'-4" 7 � L>< CD I C] pO � ---- F11 I coop �o�a � o B' o-- I -1 o0 0 0 0 0 0 0 0 o o , ❑ o o 121 _71Fo a IL-151 SGD i Pock 10'-0" Floor Plane Scale: 1 /4" = V-0" t HB L3 I L-2 L-2 25 s.h. L-2 125 s.h. 23 s.h. L-2 Egress fety 23 s.h. s.h. Egress Safety Safety 25'-4" 5'-9" 8'-10" 51_1" Glass 6'-0- Glass 16'-4" O +J O L O A _x .> date revision 1, 1/7/21 Added Flood Vents in the garage area drawn checked at P date. 'R111J-' 10/20/2020 scale REVIEWED FOR as noted ..job number CODE COMPLIANCE zDDDa ST. LUCIE COUNT sheet 13OCC A _ 1 FILE