HomeMy WebLinkAboutAPPROVED REVISE PLAN REV 1 A-0WIND VERIFATION FORM
JURISDICTION
ST. LUCIE COUNTY
CODE
FRC / FBC 2017 6TH EDITION
PROJECT NAME
GARRY WILLIAMS
PROJECT ADDRESS
INDIAN RIVER DR FT. PIFRCE
ARCHITECT/ENGINEER
JOSEPH P. McCARTY D.P.R. REG# 9639
TYPE OF CONSTRUCTION
CONCRETE BLOCK STRUCTURE
WIND SPEED NOMINAL
NOMINAL DESIGN WIND SPEED = 162 MPH
INTERNAL PRESSURE COEFFECIENT
0.18
EXPOSURE ZONE
D
IMPORTANCE FACTOR
1
BUILDING CATEGORY
2
MEAN BUILD HEIGHT
16'-0" FEET
OVERHANG
D FEET
.ROOF PITCH
0.5 / 12
COMPONENTS AND CLADDING PRESSURES +23.4 / -23.4 PSF SEE PRODUCT APPROVAL FOR WINDOWS & DOORS
ROOFTOP CHORD DEAD LOAD
7.0 PSF
ROOF TOP CHORD LIVE LOAD
20.0 PSF
ROOF BOTTOM CHORD DEAD LOAD
N/A
ROOF BOTTOM CHORD LIVE LOAD
N/A
ROOF MATERIAL
ROLLED ASPHALT ROOFING
FLOOR LIVE LOAD
N/A
FLOOR DEAD LOAD
N/A
SHUTTERS
NO
IMPACT RESISTANT ASSEMBLY
YES
BUILDING DEAPRTMENT PRODUCTAPPROVAL SUBM ITTAL AFFI DAVIT
PRODUCTAPPRL
EXP.
GLASS
ATTACHMENT
BUILDING
PRODUCT
PRODUCT
MODEL #
MANUF.
FL OR NOA#
DATE
TYPE
METHOD
D.P. (P.S,F.)
D.P. (P.S.F.)
SINGLE HUNG (SH)
NOA 18-0430.06
8/23/2023
'1100
PGT
IMPACT
012 STEEL. 18-8 OR 410 SS SCREWS,
SEE ELEVATION
+65 / -SO
9/16" FROM EDGE, 1-3/8" EMBED
PG A-2 4 A-3
VERIFY MANUF SF'EC'S FOR FASTENING SPACING
FIXED GLASS
NOA 18-0430.05
2/19/2024
PW*T120A
PGT
IMPACT
141/4" X 1-3/4" MIN, EMBED. TAPCONS o 6" FROM
SEE ELEVATION
t80.0
(PICTURE WINDOW)
CORNERS 4 12 O.C. AT PERIMETER
PG A-2 4 A-3
HORIZL. ROLLER
NOA 18-0621.01
8/23/2023
11IOA
PGT
IMPACT
012 STEEL, 18-8 CR 410 SS SCREWS,
SEE ELEVATION
+65 / -80
- 9/16" FROM EDGE, 1-3/8" EMBED
PG A-2 4 A-3
VERIFY MANUF SPECS i'OR FASTENING SPACING
AWNING WINDOW
NOA I1-0614,20
4/11/2023
AW140
PGT
IMPACT
012 STEEL, 18-8 CR 410 SS SCREWS,
SEE ELEVATION
+65 / -80
5/16" FROM EDGE, 1-3/8" EMBED
PG A-2 4 A-3
VERIFY MANUF SPECS I.OR FASTENING SPACING
SLIDING GLASS
NOA 19-1126.03
2/11V2025
TI00
PGT
IMPACT
141/4" X I-3/4" MIN, EME�IED. TAPCONS o 5" FROM -
SEE ELEVATION
t60.0
DOOR
CORNERS 4 13' O.C. AT PERIMETER
PG A-2 4 A-3
WINDOW
MULLIONS
NOA 1'1-0630.01
5/26/2021
1 x 2.15 x .03-I6
PGT
1/4" X I-3/8" MIN. EMBED. TAPCONS
SEE ELEVATION
t1T0.0
(4) PIER CLIP
PG A-2 4 A-3
OH GARA
FL 5684.16
12/3 038
4301
CLOPAY
4
1/2" X 3" LAG -RE -5/8" EMBED
EE ELEVA N
+38 / 42
DDOR,
C
PG A-2 4 A-3
EX OORS
FL 1630.
RIOR
THER TRU
I ACT
I/4' G. w/ 2-3,4" Em5EV
SEE ELEVATION
t 50.0
SMOOTH STAR
AT 14" 7.C. MAX
PG A-2 4 A-3
ROOFING
FL 1654-R24
ROLLED
NEMO ETA
IM P 9'/ C. 2"
18' O.C. AT (2) EQ L. r a CED, STAGGERED
-45.0
ASPHALT
CENTER ROWS
)AL EXR OPWITH ST NO
2) MAIN EGRESS DOOR MUST BE IMPACT RESISTANT
3) ALL GLASS SHALL HAVE A U-FACTOR LESS THAN OR EQUAL TO 0.40 AND SHGC LESS OR EQUAL TO 0.25
1) ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH NEC (NFPA 70) 2014 EDITION
2) A MINIMUM OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFACY
LAMPS OR MINIMUM OF 75% OF THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY
HIGH-EFFACY LAMPS. (LOW VOLTAGE LIGHTING SHALL NOT BE REQUIRED TO BE HIGH -EFFICIENCY LAMPS)
3) RECESSED LIGHTING SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN CONDITIONE AND UNCONDITIONED
SPACES
4) SMOKED DETECTORS TO BE 110V W/ BATTERY BACK-UP, ARC FAULT CIRCUIT
5) SMOKE DETECTORS TO BE INTERCONNECTED SO THAT ONE SMOKE DETECTOR ACTIVATES ALL SMOKE
DETECTOR IN THE RESIDENCE
6) PROVIDE BRANCH CIRCUIT ARC -FAULT PROTECTION FOR ALL CIRUITS SERVING: FAMILY ROOMS,DINING
ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS,
CLOSETS, HALLWAYS; OR SIMILAR ROOMS PER FBC AND NEC REQUIREMENTS
7) PROVIDE GROUND -FAULT CIRUIT INTERRUPTER PROTECTION FOR -ALL 125 VOLT, SINGLE PHASE 15 AND
-ENERGY CONSERVATION NOTES
20 AMP CIRUITS SERVING: BATHROOMS, GARAGES, KITCHENS, ACCESSORY BUILDINGS, OUTDOORS, OR
WITHIN 72" OF EDGE OF ANY SINK.
8) CARON MENOXIDE DETECTORS TO BE INSTALLED WITHIN 10' OF ALL BEDROOMS
9) EXHAUST FANS TO BE VENTED THROUGH ROOF OR SOFFIT
10) PROVIDE TAPER RESISTANT RECEPTICLES PER NEC REQUIREMENTS
STRUCTURAL NOTES
1) DESIGN LOADS IN ACCORDANCE WITH ASCE 7-10
2) SOIL BEARING CAPICITY: 2500 PSF (MIN.)
3) ALL STRUCTURAL CONCRETE IN BEAMS, LINTELS, VERTICAL CELLS, AND COLUMNS SHALL HAVE A
MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS
4) SLAB / FOOTINGS TO BE CONCRETE WITH A MINIMUM OF 2500 PSI COMPRESSIVE STRENGTH AT 28 DAYS.
SEE PLAN FOR SIZES AND STEEL REQUIREMENTS
5) MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTINGS; 3" BEAMS; 1-1/2" SUSPENDED SLABS: 1-1/2"
6) LAP ALL REINFORCING STEELA MINIMUM OF 48 BAR DIAMETER EXCEPT AS NOTED GRADE 60 STEEL.
MINIMUM IN BEAMS AND COLUMNS.
7) ALL LUMBER IN CONTACT WITH CONCRETE OR MASONARY SHALL BE PRESSURE TREATED
8) SPLITTING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALLATION OF HARDWARE IS NOT
PERMITTED.
9) UNLESS OTHERWISE NOTES, THE ONSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE
MANUFACTURER'S INSTRUCTIONS AND STANDARD PRACTICES.
10) UNLESS OTHERWISE NOTED, FOR EXTERIOR WALLS, EXTERIOR PLYWOOD SHEATHING AND INTERIOR
DRYWALL IS TO BE NAILED WITH 10d OR BETTER NAILS AT 6" O.C. AT EDGES AND FIELD OR SCREWED
WITH DRYWALL SCREWS 1-1/2" LONG AND 0.131 DIAMETER.
11) LINTELS SHALL HAVE A MINIMUM 4" BEARING EXCEPT RECESSED LINTELS SHALL HAVE 8" BEARING.
12) PROVIDE #5 CORNER BARS W/ 30" MIN. LAP SPLICE FOR BOND BEAM.
13) EXTERIOR FRAME WALL TO BE STUCCO OVER WIRELATHE W/ 11 GA. 2" LONG NAILS WITH 3/8" DIA. HEAD AT
6" O.C. OVER (2) TWO LAYERS OF 15# FELT ORAPRROVED BUILDING WRAP OVER 19/32" CDX PLYWOOD
WITH 10d NAILS TO STUDS AT 6" O.C. PERIMETER AND FIELD.
14) BEARING POINTS OF TRUSSES SHALL HAVE VERTICAL STUDS IN A NUMBER EQUAL TO THE NUMBER OF
PLIES OF THE BEARING MEMEBER WHEN THE BEARING MEMBER IS (2) TWO OR MORE PLIES UNLESS
NOTED.
revisions
no.
date
PROD. APP. FOR RFG 8/21120
designed
AN
drawn
BEF
checked
AN
date
11 /21 /2019
scale
1/4" = V-0" (U.N.O.)
job no.
P-XX-XXXX . COC
1) RESIDENCE SHALL BE IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017 (6th EDITION) ENERGY
CONSERVATION RESIDENTIAL.
ARCHITECT OF RECORD
2) ATTIC ACCESS DOORS OR HATCHES FROM CONDITIONED SPACES TO UNCONDITIONED SPACES SHALL
JOSEPH P. MCCARTY
BE WEATHERSTRIPPED AND INSULATED TO A LEVEL EQUIVELANT TO THE INSULATION ON THE SURROUNDING
SURFACES. A WOOD FRAMED OR EQUIVELANT BAFFLE OR RETAINER OS REQUIRED TO BE PROVIDED WHEN
ARCHITECT, Inc.
LOOSE FILL IS.INSTALLED TO PREVENT LOOSE FILL FROM SPILLING INTO THE LIVING SPACE
900 E. ®SEOLA Sl:---.
3) THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMIT AIR LEAKAGE IN ACCORDANCE WITH
S
WITH THE REQUIREMENTS R402.4.1 THROUGH R402.4.4
4) WINDOWS, SKYLIGHTS, AND SLIDING GLASS DOORS SHALL HAVE AN AIR INFILTRATION RATE OF NO MORE
. J
THAN 0.3 CFM PER SQUARE FOOT AND SWINGING DOORS NO MORE THAN 0.5 CFM PER SQUARE FOOT AND
MUST BE TESTED, LISTED, AND LABELED IN ACCORDANCE WITH R402.4.3
r
5) CONTRACTOR SHALL PROVIDE ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD IN ACCORDANCE ITH
FBC 2017 (6th EDITION) ENERGY CONSERVATION R401.3
ADDITIONAL NOTES
1) INTERIOR TO BE DRYWALL FINISHED.
2) ALL INTERIOR GYPSUM BOARD TO BE MIN 1/2" THICK WITH 13 GUAGE, 1-3/8" LONG, 19/64"HEAD; 0.098" DIA.,
1-1/4" LONG, ANNULAR -RINGED; 5d COOLER NAIL, 0.086" DIA., 1-5/8" LONG, 5/64" HEAD OR GYPSUM BOARD
NAIL 0.086" DIA. 1-5/8 LONG, 9/32" HEAD SPACED AT 7" O.C. FOR NAILS OR 12" O.C. FOR SCREWS.
3) WALLS AT SHOWERS TO BE TILE. PROVIDE CEMENT, FIBER -CEMENT OR GLASS MAT GYPSUM BACKERS IN
COMPLIANCE WITH ASTM C 1288, C 1325, C 1178, OR C 1278 AND INSTALLED IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS AS BRACKETS FOR WALL TILE IN TUB AND SHOWER AREAS AND
WALL PANELS IN SHOWER AREAS (PER FRC 702.4.1 AND FRC 702.4.2):
4) WALL AND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF NOT GREATER THAN 450.
5) WALL AND CEILING FINISHES SHALL HAVE A FLAME -SPREAD CLASSIFICATION OF NOT GREATER THAN 200.
6) AL LEXPOSED INSULATION MATERIALS INSTALLED ON ATTIC FLOORS SHALL HAVE A CRITICAL. RADIANT
FLUX NOT LESS THAN 0.12 WATTS PER SQUARE CENTIMETER. EXPOSED FOAM PLASTIC INSULATION
MATERIALS EXPOSED TO THE UNDERSIDE OF THE ROOF DECK OR ON THE ATTIC WALLS SHALL COMPLY
WITH SECTION FRC 316
7) PER FRC 702.2.1 ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL COFORM TO ASTM C 36,
C 79, C 475, C 514, C 630, C 931, C 960, C 1002, C 1047, C 1177, C1178, C 1278, C 1395, C 1396, OR C 1658
AND SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF FRC AND ADHESIVES FOR THE
INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C 557
8) INSULATION ON MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS OR VAPOR PERMEABLE
MEMBRANES INSTALLED WITHIN FLOOR -CEILING ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL
ASSEMBLIES, CRAWLL SPACES AND ATTICS SHALL HAVE AFLAME SPREAD INDEX NOT TO EXCEED 450
WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723