Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED SH7600NOA
MIAMI- MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy PGT Industries,Inc. 1070 Technology Drive North Venice,FL 34275 SCOPE:This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance if it is determined by Miami—Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "SH7600A"Aluminum Single Hung Window—N.I. APPROVAL DOCUMENT: Drawing No. 7600NOA-1,titled"Aluminum Single Hung Install(NI)",sheets 1 through 12 of 12, dated 04/01/18, with revision A dated 03/11/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E.,bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and approval date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: None LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA#18-0430.07 and consists of this page 1 and evidence pages E-1,E-2 and E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M.Utrera,P.E. 46�� NOA No.20-0401.12 MIAMI•DADE COUNTY Expiration Date: August 23,2023 Approval Date: July 30,2020 Page 1 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. Submitted under NOA # 18-0430.07 A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No. 7600NOA-1,titled"Aluminum Single Hung Install(NI), sheets 1 through 12 of 12,dated 04/01/18,prepared by manufacturer,signed and sealed by Anthony Lynn Miller, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test,per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test,per FBC 2411.3.2.1, and TAS 202-94 along with marked-up drawings and installation diagram of an aluminum single hung window,prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-18-7835.1, dated 04/03/18, signed and sealed by Idalmis Ortega, P.E. 2. Test reports on: 1) Air Infiltration Test,per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test,per FBC 2411.3.2.1, and TAS 202-94 along with marked-up drawings and installation diagram of an aluminum single hung window,prepared by Fenestration Testing Laboratory, Inc., Test Reports No. FTL-18-7835.2, dated 05/04/18, signed and sealed by Idalmis Ortega, P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 611 Edition (2017), dated 04/23/18,prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Glazing complies with ASTM E1300-09 44k�� Carlos M.Utrera,P.E. Product Control Examiner NOA No.20-0401.12 Expiration Date: August 23,2023 Approval Date: July 30,2020 E-1 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of conformance to FBC 6tn Edition(2017),dated April 24,2018,issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Statement letter of no financial interest, dated April 24, 2018, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 3. Proposal No. 18-0005R issued by the Product Control Section, dated 01/16/18, signed by Manuel Perez, P.E G. OTHERS 1. None. Z4&2�� Carlos M.Utrera,P.E. Product Control Examiner NOA No.20-0401.12 Expiration Date: August 23,2023 Approval Date: July 30,2020 E-2 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. New Evidence Submitted A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No. 7600NOA-1,titled"Aluminum Single Hung Install(NI)", sheets 1 through 12 of 12, dated 04/01/18, with revision A dated 03/11/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller,P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test,per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test,per ASTM F588 and TAS 202-94 along with marked-up drawings and installation diagram of all PGT Industries, Inc. representative units listed below and tested to qualify Dowsil 791 and Dowsil 983 silicones,prepared by Fenestration Testing Laboratory, Inc., Test Reports No.: FTL-7897,PGT PW5520 PVC Fixed Window(unit 6 in proposal), dated 09/03/14 FTL-20-2107.1,PGT SGD780 Aluminum Sliding Glass Door(unit 7 in proposal) FTL-20-2107.2,PGT CA740 Alum. Outswing Casement Window(unit 8 in proposal) FTL-20-2107.3,PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and FTL-20-2107.4, PGT PW7620A Aluminum Fixed Window(unit 10 in proposal) dated 07/13/20, all signed and sealed by Idalmis Ortega, RE C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 6"Edition (2017) and FBC 7t'Edition (2020), dated 03/10/20,prepared by manufacturer, signed and sealed by Anthony Lynn Miller,P.E. D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources(RER). E. MATERIAL CERTIFICATIONS 1. None. 44&��4 Carlos M.Utrera,P.E. Product Control Examiner NOA No.20-0401.12 Expiration Date: August 23,2023 Approval Date: July 30,2020 E-3 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance,complying with FBC 6"Edition(2017) and FBC 7' Edition(2020), dated March 10,2020,issued by manufacturer, signed and sealed by Anthony Lynn Miller,P.E. 2. Statement letter of no financial interest, dated March 10,2020,issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 3. Proposal No. 19-1155 TP issued by the Product Control Section, dated January 10, 2020, signed by Ishaq Chanda, P.E. G. OTHERS 1. Notice of Acceptance No. 18-0430.07, issued to PGT Industries, Inc. for their"Series "SH7600A"Aluminum Single Hung Window—N.I." approved on 08/23/18 and expiring on 08/23/23. 4K� Carlos M.Utrera,P.E. Product Control Examiner NOA No.20-0401.12 Expiration Date: August 23,2023 Approval Date: July 30,2020 E-4 SERIES SH7600A NON-IMPACT RESISTANT SINGLE HUNG WINDOW _1\17-13/16"MAX.o.0 DESIGN PRESSURE RATING IMPACT RATING 1)THIS PRODUCT HAS BEEN DESIGNED&TESTED TO COMPLY WITH THE REQUIREMENTS OF i18-3/8"MAX. VARIES PER GLASS TYPE, NOT RATED FOR THE FLORIDA BUILDING CODE, INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ). SEE SHEETS 2-5 IMPACT RESISTANCE 2)SHUTTERS ARE REQUIRED WHEN USED IN WIND-BORNE DEBRIS REGIONS. r!t: t /� 3)FOR MASONRY APPLICATIONS IN MIAMI-DADE COUNTY,USE ONLY MIAMI-DADE COUNTY 17-3/4"MAX. 17-3/4" 52-1/8"MAX.BUCK WIDTH APPROVED MASONRY ANCHORS.MATERIALS USED FOR ANCHOR EVALUATIONS WERE (17-1/4"BUCK) 9-1/2"MAX. SOUTHERN PINE,ASTM C90 CONCRETE MASONRY UNITS AND CONCRETE WITH MIN.KSI PER M) -11/16"MAX. ANCHOR TYPE. B,SEE _ O.C. � (9"MAX.MAX BUCK) D,SEE _ � � 5"MAX.O.C. SHEETS 8&9 SHEET 10 4)ALL WOOD BUCKS LESS THAN 1-112"THICK ARE TO BE CONSIDERED 1X INSTALLATIONS.1X A,SEE C,SEE Ff WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE.WOOD BUCKS SHEETS 8&9 FF SHEET 10 DEPICTED AS 2X ARE 1-1/2"THICK OR GREATER.1X AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED AND SECURED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE.WOOD EQUALLY BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER,(EOR)OR SPACED ARCHITECT OF RECORD,(AOR). ANCHORS PER TABLES 6&7 1 17-3/16"MAX.O.C. A) UPDATED TO FBC 5)ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR O I I / 84 O I I 83" c 2020, REVISED ANCHOR STUCCO. USE ANCHORS OF SUFFICIENT LENGTH TO ACHIEVE REQUIRED MIN.EMBEDMENT. INSTALLATION ANCHORS SHOULD BE SEALED.OVERALL SEALING/FLASHING STRATEGY FOR I P MAX. TYPE TABLE. BUCK WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND IS BEYOND THE X , 12-1/16"MAX.O.C. TO HEIGHT SCOPE OF THESE INSTRUCTIONS. TIP EQUALLY SPACED I I HEIGHT X JR- 03/11/20 6) 1/4"MAX.SHIMS ARE REQUIRED AT EACH ANCHOR LOCATION WHERE THE PRODUCT IS ANCHORS PER ' / 13-5/16"MAX.O.C. _ NOT FLUSH TO THE SUBSTRATE.USE SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. TABLES 6&7 ( I I 00 Y Q 5"MAX. W (n 7)DESIGN PRESSURES: 9-1/2"MAX. I O.C. I T C > O O �aa A.NEGATIVE DESIGN LOADS BASED ON STRUCTURAL TESTING AND GLASS PER ASTM (9"MAX.BUCK) , Nr E1300. A �- U) aOp O B.POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE,STRUCTURAL TESTING 1 O N IY O AND GLASS PER ASTM E1300. C.DESIGN LOADS ARE BASED ON ALLOWABLE STRESS DESIGN,ASD. B NO ANCHORS AT SILL D®—_ M Z 53-1/8"MAX.TIP TO TIP WIDTH1-�V WEEP NOTCH 4-11/16"MAX. I�1"WEEP NOTCH Q J o W o o C 8)THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WINDLOADS AT EACH END AT EACH END = C0 Z � (00 CORRESPONDING TO THE REQUIRED DESIGN PRESSURE.THE 33-1/3%STRESS INCREASE ELEVATION FOR TYP. FLANGE FRAME ELEVATION FOR TYP. FIN FRAME SHOWN WITH U U o `� umo�p HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT.THE 1.6 LOAD DURATION FACTOR w - 00 -I 'ON WAS USED FOR THE EVALUATION OF ANCHORS INTO WOOD.ANCHORS THAT COME INTO SHOWN WITH EQUAL-LITE CONFIGURATION EQUAL-LITE CONFIGURATION F- W Q 0Mp CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE O� > `- F- Z d FLORIDA BUILDING CODE FOR CORROSION RESISTANCE. Z Z N 9)METAL SUBSTRATE TO MEET MIN.STRENGTH AND THICKNESS REQUIREMENTS PER C7 CURRENT FLORIDA BUILDING CODE AND TO BE REVIEWED BY THE AUTHORITY HAVING GENERAL NOTES................................................. 1 Z W WO JURISDICTION. TABLE 1:ALLOWABLE GLASS TYPES ELEVATIONS......................................................... 1 = W Glass DIP PRESSURES/GLAZING DETAILS........ 2-5 ® W 06 10)REFERENCES:TEST REPORTS FTL 18-7835.1 &18-7835.2;ELCO ULTRACON NOA; Description (Listed from Exterior to Interior) ANCHOR QUANTITIES.......................................... 6-7 rn J U) DEWALT/ELCO CRETEFLEX NOA;DEWALT ULTRACON+NOA;NATIONAL DESIGN Type Table # INSTALLATION,FLANGE......................................8 � Z w }aays SPECIFICATION FOR WOOD CONSTRUCTION,ANSI/AF&PA NDS&ALUMINUM DESIGN MANUAL INSTALLATION,EQUAL LEG.................................9 Z O 1 1/8" Annealed 2 0 �n INSTALLATION,INTEGRAL FIN............................ 10 Z 11)APPLICABLE EGRESS REQUIREMENTS TO BE REVIEWED BY BUILDING OFFICIAL. 2 13/16" IG: 1/8" Annealed Cap, Airspace, 1/8"Annealed 3 EXTRUSION PROFILES.........................................11 2 J Q 3 3/16"Annealed 3 ASSEMBLY&PARTS LIST.................................... 12 Z 0 4 13/16" IG: 3/16" Annealed Cap, Airspace, 3/16" Annealed 4 w w I- CODES/STANDARDS USED: w Z = FIGURE A:ALLOWABLE SASH CONFIGURATIONS AND SHAPES 5 1/8 Tempered 5 • 2020 FLORIDA BUILDING CODE(FBC),7TH EDITION w 07 -►-� WIDTH WIDTH WIDTH f f- 6 13/16" IG: 1/8" Tempered Cap, Airspace, 1/8" Tempered 5 . 2017 FLORIDA BUILDING CODE(FBC),6TH EDITION ¢ (9 T 7 3/16" Tempered 5 • ASTM E1300-09 a'}il asap sauas r T I I j • ANSI/AF&PA NDS-2018 FOR WOOD CONSTRUCTION 8 13/16 IG: 3/16 Tempered Cap, Airspace, 3/16 Tempered 5 • ALUMINUM DESIGN MANUAL,ADM-2015 ON • AISI S100-16 � 1( L ' fl cif • AISC 360-16 _ = x J / USER INSTRUCTIONS: - No. 58 i05 1)DETERMINE THE SITE SPECIFIC,WINDOW OPENING'S DESIGN PRESSURE REQUIREMENT FROM ASCE 7. z _ P RECTANGULAR 2)KNOWING YOUR GLAZING OPTION(TABLE 1),WINDOW CONFIGURATION AND SIZE,DETERMINE YOUR WINDOWS DESIGN PRESSURE FROM TABLES I' WITH EQUAL WITH RADIUS-TOP RECTANGULAR RADIUS-TO WITH CUSTOM 2-5. IT MUST EQUAL OR EXCEED THE DESIGN PRESSURE REQUIREMENT FOR THE WINDOW OPENING OBTAINED IN STEP 1. OF LITE SASH SASH SASH 4)DETERMINE THE ANCHOR QUANTITY FROM TABLES 6&7. 111 5) INSTALL AS PER SHEET 8 FOR FLANGE INSTALLATION,SHEET 9 FOR EQUAL LEG INSTALLATION OR SHEET 10 FOR INTEGRAL FIN INSTALLATION. �(0,R f ALL SHAPES WITH ALL SASH CONFIGURATIONS ARE APPROVED.SHAPES MAY BE USED BY INSCRIBING THE SHAPE IN A BLOCK AND OBTAINING NOTE:DESIGN PRESSURE RATING DETERMINATION IS THE SAME PROCESS FOR ALL FRAME TYPES(FLANGE,INTEGRAL FIN OR EQUAL LEG/BOX). rl i4�t DESIGN PRESSURES AND ANCHORAGE FOR THAT BLOCK SIZE FROM THE A.LYN(t�MILLER,P.E. TABLES ON THE FOLLOWING SHEETS. P.E.#58705 TABLE 2: Bottom Sash Design Pressure(Ibs/fe)for Glass Type 1 Description Sash Height for Given Range Range(in) Tip to Tip Width 18" 25" 33" 37" 41" 45" 49" 53-1/8" 24" Equal-lite 12,464 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 1 -127.1 +80.0 -113.8 +80.0 -103.1 +80.0 -93.9 Equal-lite 15.964 +80.0 -130.0 +80.0 -130.0 +80.0 -104.0 +80.0 -95.5 +80.0 -89.1 +80.0 -84.2 +80.0 -81.4 +74.8 -74.8 1/8"ANNEALED 31" Standard Proview 12.994-15.963 +80.0 -130.0 +80.6 -127.0 +80.0 -86.9 +760 -76.0 +66.7 -66.7 +60.7 -60.7 +57.2 -57.2 +53.5 -53.5 GLASS Shortest 12.464-12.993 +80.0 -130.0 +80.0 -124.0 +80.0 -84.0 +73.8 -73.8 +63.2 -63.2 +57.2 -57.2 +52.4 -52A +49.1 -49.1 Equal-lite 19,652 +80.0 -130.0 +80.0 -124.0 +80.0 -84.0 +73.8 -73.8 +63.2 -63.2 +5T2 -57.2 +52.4 -52.4 +49.1 -49.1 30 Standard ProAew 15.944-19.651 +80.0 1 -130.0 1 +80.0 -110.0 1 +80.0 -80.6 +70.3 -70.3 +60.2 -60.2 +52.2 -52.2 +46.8 -46.8 +41.0 41.0 38-3/8" Custom Size 15.131-15.943 +80.0 -130.0 +80.0 -102.0 +78.2 -78.2 +68.7 -68.7 +59.3 -59.3 +51.7 51.7 +46.2 -46.2 +40.0 40.0 26 Custom Size 14.131-15.130 +80.0 -124.0 +80.0 -98.5 +77.1 -77.1 +67.4 -67.4 +58.9 -58.9 +51.5 -51.5 +46.1 -46.1 +39.9 -39.9 1/2"NOM. Shortest 12.464-14.130 +80.0 -118.0 +80.0 -95.2 +75.4 -75.4 +66.1 -66.1 +58.5 -58.5 +51.3 -51.3 +46.1 -46.1 +40.0 -40.0 GLASS BITE EXTERIOR Equal-lite 22.964 +80.0 -130.0 +80.0 -110.0 +80.0 -80.6 +70.3 -70.3 +60.2 -60.2 +52.2 -52.2 +46.6 -46.8 +41.0 -41.0 Custom Size 20.131-22,963 +80.0 -124.0 +80.0 -98.5 +77.1 -77.1 +67.4 -67.4 +58.9 -58.9 +51.5 -51.5 +46.1 -46.1 +39.9 -39.9 `�J�_I Standard Proview 18.594-20.130 +80.0 -118.0 +80.0 -95.2 +75.4 -75.4 +66.1 -66.1 +58.5 -58.5 +51.3 -51.3 +46.1 -46.1 +40.0 -40.0 74 45" Custom Size 16.131-18.593 +80.0 -102.0 +80.0 -85.0 +69.9 -69.9 +62.1 -62.1 +55.7 -55.7 +50.4 -50.4 +45.3 -45.3 +40.0 -40.0 34 A) NO CHANGES THIS Custom Size 15.131-16.130 +80.0 -98.0 +80.0 -81.9 +68.1 -68.1 +60.6 -60.6 +54.6 -54.6 +49.7 -49.7 +44.8 -44.8 +39.9 -39.9 o SHEET. Custom Size 14.131-15.130 +80.0 -95.5 +79.4 -79.4 +66.4 -66.4 +59.2 -59.2 +53.6 -53.6 +48.7 -48.7 +44.3 -44.3 +39.7 -39.7 GLASS TYPE 1 Shortest 12.464-14.130 +80.0 -89.4 +74.6 -74.6 +62.1 -62.1 +56.3 -56.3 +51.1 -51.1 +46.7 -46.7 +42.7 -42.7 +38.6 -38.6 JR- 03/11/20 Equal-lite 24.964 +80.0 -130.0 +80.0 -102.0 +78.2 -78.2 +68.7 -68.7 +59.3 -%3 +51.7 -51.7 +46.2 -46.2 +40.0 -40.0 Custom Size 22.131-24.963 +80.0 -112.0 +80.0 -92.0 +73.5 -73.5 +64.8 -64.8 +57.9 -57.9 +51.0 -51.0 +46.0 -46.0 +40.0 -40.0 L °1 Standard Prov+ew 20.194-22.130 +80.0 -102.0 +80.0 -85.0 +69.9 -69.9 +62.1 -62.1 +55.7 -55.7 +50.4 -50.4 +45.3 -45.3 +40.0 -40.0 Q c 00 49" Custom Size 18.131-20.193 +80.0 95.5 +79.4 -79.4 +66.4 66.4 +59.2 59.2 +53.6 53.6 +48.7 48.7 +44.3 �14.3 +39.7 39.7 w i= Custom Size 16.131-18.130 +80.0 -89A +74.6 -74.6 +62.1 -62.1 +56.3 -56.3 +51.1 -51.1 +46.7 -46.7 +42.7 -42.7 +38.6 -38.6 > 6 p �j •nab _n Custom Size 14.131-16,130 +80.0 -84.6 +69.5 -69.5 +59.2 -59.2 +53.7 -53.7 +48.8 -48.8 +44.8 -44.8 +40.9 -40.9 +37.6 -37.6 0Y O ~ Shortest 12.464-14.130 +80.0 -81.9 +64.0 -64.0 +56A -56.4 +51.0 -51.0 +46.6 -46.6 +42.3 -42.3 +39.4 -39.4 +36.0 36.0 � O Equal-lite 25.777 +80.0 -124.0 +80.0 -98.5 +77.1 -77.1 +67.4 -67.4 +58.9 -58.9 +51.5 -51.5 +46.1 -46.1 +39.9 -39.9 N a}DQ W 0 Custom Size 24.131-25.776 +80.0 -112.0 +80.0 -92.0 +73.5 -73.5 +64.8 -64.8 +57.9 -57.9 +51.0 -51.0 +46.0 -46.0 +39.9 -39.9 0 M U) Z Standard Proview 20.844-24.130 +80.0 -98.0 +80.0 -81.9 +68.1 -68.1 +60.6 -60.6 +54.6 -54.6 +49.7 -49.7 +44.8 A4.8 +39.9 -39.9 O J O W O 50-5/8" Custom Size 19.131-20.843 +80.0 -92.6 +77.0 -77.0 +64.1 -64.1 +57.7 -57.7 +52.3 -52.3 +47.7 -47.7 +43:8 -43.8 +39.2 -39.2 Z (0 Custom Size 16.131-19.130 +80.0 -84.6 +69.5 -69.5 +59.2 -59.2 +53.7 -53.7 +48.8 -48.8 +44.8 -44.8 +40.9 -40.9 +37.6 -37.6 = W � Z ,f8 ti Shortest 13.089*-16.130 +80.0 -80.6 +61.7 -61.7 +55.1 -55.1 +49.8 -49,8 +45.5 -45.5 +41.3 -41.3 +38.6 -38,6 +35.1 -35.1 W U 00 UM -1 00 -I 'ON Equal-lite 31.964 +80.0 -95.5 +79.4 -79.4 +66.4 -66.4 +%2 -59.2 +53.6 -53.6 +48.7 -48.7 +44.3 -44.3 +39.7 -39.7 O W Q SM0 Custom Size 28.131-31.963 +80.0 -84.6 +69.5 -69.5 +59.2 -%2 +53.7 -53.7 +48.8 -48.8 +44.8 -44.8 +40.9 -40.9 +37.6 -37.6 ti > N 63" Standard Proview 25,794-28.130 +80.0 -80.6 +61.7 -61.7 +55.1 -55.1 +49.8 -49.8 +45.5 -45.5 +41.3 -41.3 +38.6 -38.6 +35.1 -35.1 Z Z Shortest 25.049*-25,793 +80.0 -80.6 +61.7 -61.7 +55.1 -55.1 +49.8 -49.8 +45.5 -45.5 +41.3 -41.3 +38.6 -38.6 +35.1 -35.1 N Equal-lite 34.964 +80.0 -86.5 +72.2 -72.2 +60.6 -60.6 +55.0 -55.0 +49.9 -49.9 +45.8 -45.8 +41.7 -41.7 +38.1 -38.1 Z L.L 69" Custom Size 33.131-34.963 +80.0 -83.1 +66.7 -66.7 +5T8 -57.8 +52.1 -52.1 +47.6 -47.6 +43.5 -43.5 +40.1 -40.1 +36.8 -36.8 O Shortest 31.049*-33.130 +80.0 -80.6 +61.7 -61.7 +55.1 -55.1 +49.8 -49.8 +45.5 -45.5 +41.3 -41.3 +38.6 -38.6 +35.1 -35.1 = N Equal4ite 36.964 +80.0 -83.1 +66.7 -66.7 +5T8 -57.8 +52.1 -52.1 +47.6 -47.6 +43.5 -43.5 +40.1 -40.1 +36.8 -36.8 ® rn J 73" Custom Size 36,131-36.963 +80.0 -81.9 +64.0 64.0 +56.4 -56A +51.0 -51.0 +46.6 46.6 +42.3 -42.3 +39.4 -39.4 +36.0 -36.0 N Z }aayS Shortest 35.049*-36,130 +80.0 -80.6 +61.7 -61.7 +55.1 -55.1 +49.8 -49.8 1 +45.5 -45.5 +41.3 -41.3 +38.6 -38.6 +35.1 -35.1 0 CD 76" Tallest 38.464* +80.0 -80.6 +61.7 -61.7 +55.1 -55.1 1 +49.8 79.8 +45.5 -45.5 +41.3 1 -41.3 1 +38.6 -38.6 +35.1 -35.1 F- *MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-37.536 J MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-36.536 U) Z m 0 MINIMUM SASH HEIGHT FOR FLANGED,RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-37.951 w 2 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG,RADIUS TOP WINDOWS IS:BUCK HEIGHT-36.951 J Q 0 al}il •Dsap sauas `,,�r1iil111fJJ M No. 58705 CM LZ 1)TIP TO TIP DIMENSIONS SHOWN. FOR INTEGRAL FIN AND EQUAL-LEG WINDOWS,SUBTRACT 1"FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. °,r/I�-rNA 2)FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. 3)FOR RADIUS TOP WINDOWS,FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. A.LYNN MILLER,P.E. 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF+65 PSF.NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. P.E.#58705 TABLE 3: Bottom Sash Design Pressure(lbstW)for Glass Types 2&3 Description Sash Height Range(in) Tip to Tip Width GLASS STACK for Given Range 18" 25" 33" 37" 41" 45" 49" 53-1/8" 24" Equal-lite 12.464 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -124.8 AIRSPACE Equal-lite 15.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80,0 -130.0 +80.0 -121.6 +80.0 -109.6 +80.0 -99.5 1/8"ANNEALED GLASS 31" Standard Proview 12.994-15.963 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -120.1 +80.0 -109.3 +80.0 -102.6 +80.0 -93.0 31 74 Shortest 12.464-12.993 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -113.8 +80.0 -103,0 +80.0 -94.3 +80.0 -88.4 Equal-lite 19.652 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -113.8 +80.0 -102.8 +80.0 -92.2 +80.0 -83.3 5�OR 5B 1/2"NOM. Standard Proview 15,944-19.651 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -125.0 +80.0 -108.4 +80.0 -94.0 +80.0 -84.2 +73.8 -73.8 EXTERIOR GLASS BITE 38-3/8" Custom Size 15.131-15.943 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -114.0 +80.0 -101.0 +80.0 -90.6 +80.0 -81.6 +72.0 -72.0 Custom Size 14.131-15.130 +80.0 -130.0 +80.0 -130.0 +80.0 -129.0 +80.0 -110.0 +80.0 -97.7 +80.0 -87.1 +78.8 -78.8 +71.8 -71.8 Shortest 12.464-14.130 +80.0 -130.0 +80.0 -130.0 +80.0 -124.0 +80.0 -107.0 +80.0 -94.8 +80.0 -84.0 +76.8 -76.8 +68.9 -68.9 Equal-lite 22.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -121.1 +80.0 -104.4 +80.0 -91.7 +80.0 -81.8 +73.6 -73.6 70-73 35 OR 35B Custom Size 20.131 -22.963 +80.0 -130.0 +80.0 -130.0 +80.0 -129.0 +80.0 -110.0 +80.0 -97.7 +80.0 -87.1 +78.3 -78.3 +70.3 -70.3 Standard Proview 18.594-20.130 +80.0 -130.0 +80.0 -130.0 +80.0 -124.0 +80,0 -107.0 +80.0 -94.8 +80.0 -84.0 +76.8 -76.8 +68.9 -68.9 GLASS TYPE 2 A) NO CHANGES THIS 45" Custom Size 16.131 -18.593 +80.0 -130.0 +80.0 -130.0 +80.0 -112.0 +80.0 -99.1 +80.0 -87.5 +79.2 -79.2 +72.0 -72.0 +62.5 -62.5 SHEET. c Custom Size 15.131-16.130 +80.0 -130.0 +80.0 -130.0 +80.0 -109.0 +80.0 -96.7 +80.0 -85.4 +78.0 -78.0 +70.8 -70.8 +61.5 -61.5 2 Custom Size 14.131-15,130 +80.0 -130.0 +80.0 -130.0 +80.0 -105.0 +80.0 -94.5 +80.0 -83.5 +76.8 -76.8 +69.7 -69.7 +60,6 -60.6 JR - 03/11/20 Shortest 12,464-14.130 +80.0 -130.0 +80.0 -127.0 +80.0 -99.8 +80.0 -90.7 +80.0 -81.2 +74.8 -74.8 +67.7 -67.7 +59.6 -59.6 Equal-lite 24.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -114.0 +80.0 -99.1 +80.0 -86.7 +77.0 -77.0 +69.1 -69.1 Custom Size 22.131-24,963 +80.0 -130.0 +80.0 -130.0 +80,0 -120.0 +80.0 -104.0 +80.0 -92.2 +80.0 -82.1 +74.2 -74.2 +66.3 -66.3 Standard Proview 20.194-22.130 +80.0 -130.0 +80.0 -130.0 +80.0 -112.0 +80,0 -99.1 +80.0 -87.5 +79.2 -79.2 +72.0 -72.0 +62.5 -62.5 00 Y Q 3/16"ANNEALED W (>n 49" Custom Size 18.131 -20.193 +80.0 -130.0 +80.0 -130.0 +80.0 -105.0 +80.0 94.5 +80.0 83.5 +76.8 76.8 +69.7 69.7 +60.6 60.6 GLASS > O Custom Size 16.131-18.130 +80.0 -130.0 +80.0 -127.0 +80.0 -99.8 +80.0 -90.7 +80.0 -81.2 +74.8 -74.8 +67.7 -67.7 +59.6 -59,6 4 0 Custom Size 14.131-%130 +80.0 -130.0 +80.0 -120.0 +80.0 -94.5 +80.0 -87.3 +79.0 -79.0 +72.9 -72.9 +65.8 -65.8 +58.7 -58.7 30 0 07 Shortest 12.464-14.130 +80.0 130.0 +80.0 112.0 +80.0 89.1 +80.0 82.3 +76.9 -76.9 +70.5 70.5 +64.2 64.2 +57.6 57.6 } t- a}op Q' E ual-lite 25.777 +80.0 -130.0 +80.0 -130.0 +80.0 -129.0 +80.0 -110.0 +80.0 -97.2 +80.0 -84.9 +75.4 -75.4 +67.5 -67.5 26 (� 'q O q *qe 2"NOM. Cry z Z n Custom Size 24.131 -25.776 +80.0 -130.0 +80.0 -130.0 +80.0 -120.0 +80.0 -104.0 +80.0 -92.2 +80.0 -82.1 +73.8 -73.8 +66.0 -66.0 ASS BITE Q J C W O Standard Provnew 20.844-24.130 +80.0 -130.0 +80.0 130.0 +80.0 109.0 +80.0 96.7 +80.0 85.4 +78.0 78.0 +70.8 70.8 +61.5 61.5 EXTERIOR u- � � Q. Custom Size 20A31-20.843 +80.0 -130.0 +80.0 -130.0 +80.0 -105.0 +80.0 -94.5 +80.0 -83.5 +76.8 -76.8 +69.7 -69.7 +60.6 -60.6 = W Z Xa i= 50-5/8" Custom Size 18.131-20.130 +80.0 -130.0 +80.0 -127.0 +80.0 -99.8 +80.0 -90.7 +80.0 -81.2 +74.8 -74.8 +67.7 -67.7 +59.6 -59.6 W U 00 J uMOJp oN Custom Size 16.131 -18.130 +80.0 -130.0 +80.0 -120.0 +80.0 -94.5 +80.0 -87.3 +79.0 -79.0 +72.9 -7Z9 +65.8 -65.8 +58.7 -58.7 F- W Q 0Ma Custom Size 14.131-16,130 +80.0 -130.0 +80.0 -112.0 +80.0 -89.1 +80.0 -82.3 +76.9 -76.9 +70.5 -70.5 +64.2 -64.2 +57.6 -57.6 34 O > v Shortest 12.464-14.130 +80.0 -130.0 +80.0 -108.0 +80.0 -86.4 +80.0 -80.6 +75.8 -75.8 +69.3 -69.3 +63.5 -63.5 +57.0 -57.0 GLASS TYPE 3 o Z 0 Z Equal-lite 31.964 +80.0 -130.0 +80.0 -130.0 +80.0 -105.0 +80.0 -94.5 +80.0 -83.5 +75.4 -75.4 +66.1 -66.1 +58.6 -58.6 N 0 Custom Size 28.131-31.963 +80.0 -130.0 +80.0 -120.0 +80.0 -94.5 +80.0 -87.3 +79.0 -79.0 +72.9 -72.9 +64.1 -64.1 +56.7 -56.7 Z W Standard Proview 25.794-28.130 +80.0 -130.0 +80.0 -108.0 +80.0 -86.4 +80.0 -80.6 +75.8 -75.8 +69.3 -69.3 +63.5 -63.5 +57.0 -57.0 0 =Custom Size 24.131 -25,793 +80.0 -130.0 +80.0 -105.0 +80.0 -83.5 +79.0 -79.0 +74.8 -74.8 +68.2 -68.2 +62.3 -62.3 M+56.5 -56.5 W 63" Custom Size 22.131 -24.130 +80.0 130.0 +80:0 -99.8 +80.0 -80.2 +75.9 -75.9 +71.4 71.4 +65.9 65.9 +60.6 60.6 +55.4 55.4 ® M J Custom Size 20.131 -22.130 +80.0 -130.0 +80.0 -93.4 +76.8 -76.8 +72.9 -72.9 +68.2 -68.2 +63.8 -63,8 +58.9 -58.9 +54.0 -54.0 z }aagS Custom Size 18.131-20.130 +80,0 -130.0 +80.0 -88.6 +73.4 -73.4 +69.5 -69.5 +65.1 -65.1 +61.1 -61.1 +57.3 -57.3 +52.1 -52.1 0 Fn Custom Size 16.131-18,130 +80.0 -129.1 +80.0 -83.7 +69.7 -%7 +65.8 -65.8 +62.3 -62.3 +58.9 -58.9 +55.7 -55.7 +50.8 -%8 c� Q Shortest 13.194*-16,130 +80.0 -125.5 +75.8 -75.8 +63.7 -63.7 +61 A -61.1 +58.9 -58.9 +55.9 -55.9 +52.3 -52.3 +48.6 -48.6 F W O J � Equal-lite 38A64 +80.0 -130.0 +80.0 -108.0 +80.0 -86.4 +80.0 -80.6 +75.8 -75.8 +69.3 -69.3 +60.7 1 -60.7 +53.2 1 -53.2 U) Z Co Custom Size 36.131-38.463 +80.0 -130.0 +80.0 -102.0 +80,0 -81.8 +77.4 -77.4 +73.1 -73.1 +67.0 -67.0 +60.0 -60.0 +52.5 -52.5 w Custom Size 34,131-36.130 +80.0 -130,0 +80.0 -96.7 +78.5 -78.5 +74.4 -74.4 +69.8 -69.8 +64.8 -64.8 +59.7 -59.7 +52.7 -52.7 0- J 76" Standard Proview 30.994-34.130 +80.0 -130.0 +80.0 -88.6 +73.4 -73.4 +69.5 -69.5 +65.1 -65.1 +61.1 -61.1 +57.3 -57.3 +52.1 -52.1 Q al}rj `Sac sauas Custom Size 30.131-30.993 +80.0 -130.0 +80.0 -86.2 +71.6 -71.6 +67.7 -6T7 +63.6 -63.6 +60.0 -60.0 +56.5 -56.5 +51.4 -51.4 Custom Size 28.131-30,130 +80.0 -127.8 +80.0 -81.0 +67.8 -67.8 +64.0 -64.0 +61.4 -61.4 +57.9 -57.9 +54.5 -54.5 +50.1 -50.1 Shortest 26,194*-28.130 +80.0 -125.5 +75.8 -75.8 +63.7 -63.7 +611 -61.1 +58.9 -58,9 +55.9 -55.9 +52.3 -52.3 +48.6 -48.6 �,\11 � Equal-life 42.464 +80.0 -130.0 +80.0 -96.7 +78,5 -78.5 +74.4 -74.4 +69.8 -69.8 +64.8 -64.8 +58.9 58.9 +51.1 51.1 84" Custom Size 38.131-42.463 +80.0 -130.0 +80.0 -86.2 +71.6 -71.6 +67.7 -67.7 +63.6 -63.6 +60.0 -60.0 +56.5 -56.5 +50A -50.4 _ J Standard Proview 34.194*-38.130 +80.0 1 -125.5 +75.8 -75.8 +63.7 -63.7 +61.1 -61.1 +58.9 -58.9 1 +55.9 -55.9 +52.3 -52.3 +48.6 1 -48.6 y a I'O 51 011; MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-49.391 - MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-48.391 MINIMUM SASH HEIGHT FOR FLANGED,RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-49.806 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG,RADIUS TOP WINDOWS IS:BUCK HEIGHT-48.806 A '• T E 1)TIP TO TIP DIMENSIONS SHOWN.FOR INTEGRAL FIN AND EQUAL-LEG WINDOWS,SUBTRACT 1"FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. 2)FOR SIZES NOT SHOWN,ROUND UP TO THE NEXT AVAILABLE SIZE. 3)FOR RADIUS TOP WINDOWS, FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. A.LYNN MILLER,P.E. 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF+65 PSF.NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. P.E.#58705 TABLE 4: Bottom Sash Sash Height Design Pressure(lbs/ft2)for Glass Type 4 Description Range(in) Tip to Tip Width for Gi,en Range 13/16"NOW 18" 25" 33" 37" 41" 45" 49" 53-1/8" ) 24" Equal-lite 12.464 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 130.0 I GLASS STACK Equal-lite 15.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 31" Standard ProHew 12.994-15.963 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 AIRSPACE Shortest 12.464-12.993 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 GLASS ANNEALED GLASS Equal-lite 19.652 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 Standard Proview 15.944-19.651 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -122.0 +80.0 -112.0 74 31 38-3/8" Custom Size 15.131-15.943 +80.0 130.0 +80.0 130.0 +80:0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 Custom Size 14.131-15.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -129.6 @OR 5B 1/2"NOM. Shortest 12.464-14,130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -124.0 GLASS BITE Equal-lite 22.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -117.7 EXTERIOR Custom Size 20.131 -22.963 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -125.3 +80.0 -112.5 a Standard Pro\Aew 18.594-20.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -129.1 +80.0 -116.0 70-73 A) NO CHANGES THIS 45 Custom Size 16.131 -18.593 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -126.0 +80.0 -112.5 35 OR 35B SHEET. Custom Size 15.131 -16.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -127.4 +80.0 -110.7 Custom Size 14A31-15.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -125.5 +80.0 -109.1 GLASS TYPE 4 JR- 03/11/20 Shortest 12.464-14.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -121.9 +80.0 -107.3 Equal-lite 24.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -123.3 +80.0 -110.6 Custom Size 22.131-24.963 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -118.7 +80.0 -106.3 Standard Proview 20.194-22.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -121.3 +80.0 -108.6 00 Y Q 49 Custom Size 18.131-20.193 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -120.8 +80.0 -108.1 >� Custom Size 16.131-18.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -121.9 +80.0 -107.3 O � d O Custom Size 14.131-16.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -118.4 +80.0 -105.7 O 0) LO ao O Q 1= Shortest 12.464-14.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -126.9 +80.0 -115.6 +80.0 -103.7 � N ; � � Equal-lite 25.777 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -120.6 +80.0 -108.1 O d U a Custom Size 24.131 -25.776 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -118.1 +80.0 -105.7 O J O W O ~ Standard ProHew 20.844-24.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -116.7 +80.0 -104.3 Z D _") O 0 fl. Custom Size 20,131 -20.843 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -120.1 +80.0 -107.4 = W Z 1(8 ~ i= 50 5/8" Custom Size 1131-20.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -119.8 +80.0 -107.0 U U 00 8. uMo�p W � -I -ON Custom Size 16.131-18,130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -118.4 +80.0 -105.7 N W Q ONIG Custom Size 14.131-16.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 1 -126.9 +80.0 -115.6 +80.0 -103.7 Oi'_ Shortest 12.464-14.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -124.7 +80.0 -114.3 +80.0 -102.6 Z Z_ Equal-lite 31.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -120.6 +80.0 -105.7 +76.2 -93.8 fV U � Custom Size 28.131-31.963 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -117.5 +80.0 -102.6 +73.7 -90.8 Z LL Standard Prowew 25.794-28.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -119.8 +80.0 -104.6 +75.2 -92.6 O Custom Size 24.131-25.793 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 1 +80.0 -130.0 +80.0 -130.0 1 +80.0 -121.8 +80.0 -106.3 +76.4 -94.0 rn W 63" Custom Size 22.131-24.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -128.5 +80.0 -118.6 +80.0 -107.4 +77.0 -94.8 ® rn J Custom Size 20.131-22.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -122.8 +80.0 -114.8 +80.0 -106.0 +78.3 -96.3 ft 04 Z $aays Custom Size 1&131-20.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -125.1 +80.0 -117.2 +80.0 -110.0 +80.0 -103.1 +79.9 -93.8 0 Fn Custom Size 16.131 -18.130 +80.0 -130.0 +80.0 -130.0 +80.0 -125.5 +80.0 -118.4 +80.0 -112.1 +80.0 -106.0 +80.0 -100.3 +80.0 -91.4 i-- Shortest 13.194*-1&130 +80.0 -130.0 +80.0 -130.0 +80.0 -114.7 +80.0 -110.0 +80.0 -106.0 +80.0 1 -100.6 +80.0 -94A +80.0 -87.8 g J 00 Equal-lite 38.464 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -112.5 +78.9 -97.1 +69.1 -85°1 U) Z Q Custom Size 36.131-38,463 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -111.7 +78.1 -96.1 +68.2 -84.0 ww j H _ Custom Size 34,131-36.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -125.6 +80.0 -112.1 +78.4 -96.5 +68.5 -84.4 J d 76" Standard ProHew 30.994-34.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -125.1 +80.0 -117.2 +80.0 -1%0 1 +78.7 -96.9 1 +68.7 -84.5 Q al}il •asaa sauas Custom Size 30.131-30.993 +80.0 -130.0 +80.0 -130.0 +80.0 -128.9 +80.0 -121.9 +80.0 -114.5 +80.0 -108.0 +80.0 -99.0 +70.2 -86.4 Custom Size 28.131-30.130 +80.0 -130.0 +80.0 -130.0 +80.0 -122.0 +80.0 -115.2 +80.0 -110.5 +80.0 -104.2 +80.0 -98.1 +70.4 -86.6 , t}i t fill; Shortest 26.194*-28.130 +80.0 -130.0 +80.0 -130.0 +80.0 -114.7 +80.0 -110.0 +80.0 -106.0 +80.0 -100.6 +80.0 -94.1 +71.5 -87.8 e��` 5�� L , I f e Equal-lite 42A64 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -125.6 +80.0 -110.4 +76.5 -94.2 +66.5 -81.8 , ??� '°..••.. 41z' fpf 84" Custom Size 38.131-42,463 +80.0 -130.0 +80.0 -130.0 +80.0 -128.9 +80.0 -121.9 +80.0 -114.5 +80.0 -108.0 +75.8 -93.3 +65.5 -80.6 1 Fri ,O Standard Prmhew 34.194*-38.130 +80.0 -130.0 +80.0 -130.0 +80.0 -114.7 +80.0 -110.0 +80.0 -106.0 +80.0 -100.6 +76.8 -94.1 +66.3 81.6 ; *MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-49.391 )0' 58705 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-48.391 _ MINIMUM SASH HEIGHT FOR FLANGED, RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-49.806 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG,RADIUS TOP WINDOWS IS:BUCK HEIGHT-48.806 nAT40 Pi 1)TIP TO TIP DIMENSIONS SHOWN.FOR INTEGRAL FIN AND EQUAL-LEG WINDOWS,SUBTRACT 1"FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. l' Jr6 �kw�a 2)FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. ///!1 i i i I t i 3)FOR RADIUS TOP WINDOWS,FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. A.LYNN MILLER,P.E. 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF+65 PSF.NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. P.E.#58705 TABLE 5: Bottom Sash Bash Height Design Pressure(lbs/fe)for Glass Types 5-8 Description Range(in) Tip to Tip Width 1/8"TEMPERED GLASS for Given Range 18" 25" 33' 37" 41" 45" 49" 53-1/6' 24" Equal-lite 12.464 +80.0 -130.0 +80.0 -130.0 +80,0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 130.0 +80.0 130.0 +80.0 130.0 30 Equal-lite 15.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 26 31" Standard Proview 12.994-15,963 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 2/2SN OM. Shortest 12.464-12.993 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 BITE Equal-lite 19.652 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 EXTERIOR Standard Proview 15.944-19.651 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -122.0 +80.0 -112.0 a 38-3/8" Custom Size 15.131-15.943 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80:0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 74 Custom Size 14.131-15.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 34 Shortest 12.464-14.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 GLASS TYPE 5 Equal-lite 22.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -117.7 Custom Size 20.131-22.963 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 1 -130.0 +80.0 -130.0 +80.0 -125.3 +80.0 -112.5 Standard Proview 18.594-20,130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 GLASS +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -129.1 +80.0 -116.0 NOM. GLASS STACK A) NO CHANGES THIS 45" Custom Size 16.131-18.593 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -126.0 +80.0 -113.7 SHEET. c Custom Size 15.131 16.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -118.6 AIRSPACE 2 Custom Size 14.131-15.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -119.5 1/8"TEMPERED GLASS Shortest 12.464-14,130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -119.7 JR - 03/11/20 31 74 Equal-lite 24.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -123.3 +80.0 -110.6 Custom Size 22.131-24.963 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -118.7 +80.0 -106.3 5@OR 5B 1/2"NOM. Standard Proview 20.194-2Z130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -121.3 +80.0 -108.6 GLASS BITE T_ Y Q 49" Custom Size 18.131-20.193 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -120.8 +80.0 -108.1 t�� Ze EXTERIOR ? (>n Custom Size 16.131-18,130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -123.5 +80.0 -110.3 > naa d O Custom Size 14.131-16.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -125.8 +80.0 -112.1 O U) LO Shortest 12.464-14.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -129.2 +80.0 -114.9 70-73 �•- 2100 O Q Equal-lite 25.777 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -120.6 +80.0 -108.1 35 OR 5B GLASS TYPE 6 O M 0 n Custom Size 24.131-25.776 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -118.1 +80.0 -105.7 Q J O W O o Standard PrWew 20.844-24,130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -116.7 +80.0 -104.3 Z LL � -� C,7 a Custom Size 20.131-20.843 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -120.1 +80.0 -107.4 = LL Z �8 i= 50-5/8" Custom Size 18.131-20.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +8&0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -119.8 +80.0 -107.0 3/16"TEMPERED W U 00 uMOJO W 00 J 'ON Custom Size 16.131-18.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -121.7 +80.0 -108.5 GLASS I - W Q 9M0 Custom Size 14.131-16.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -124.2 +80.0 -110.5 30 H L7 Shortest 12.464-14,130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -127.8 +80.0 -113.4 26 Z Z_ Equal-lite 31.964 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -120.6 +80.0 -105.7 +76.2 -93.8 1/2"NOM. ( Custom Size 28.131-31.963 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -117.5 +80.0 -102.6 +73.7 -90.8 GLASS BITE Z LL Standard Pro,.iew 25.794-28,130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -119.8 +80.0 -104.6 +75.2 -92.6 EXTERIOR O LO Custom Size 24.131-25.793 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 130.0 +80.0 121.8 +80.0 106.3 +76.4 94.0 rn W 63" Custom Size 22.131-24.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -123.3 +80.0 -107A +77.0 -94.8 74 Custom Size 20.131-22.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -126.0 +80.0 -109.4 +78.3 -96.3 34 Z Z aaa4S Custom Size 18.131 -20.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -129.4 +80.0 -112.0 +79.9 -98.3 GLASS TYPE 7 0 Custom Size 16,131-18.130 +80.0 -130.0 +80.0 -130.0 +80.0 1 -130.0 +80.0 1 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -11&1 +80.0 -100.7 Q Shortest 13.194*-16.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -129.2 +80.0 -118.8 +80.0 -103.5 W O J O Equal-lite 38.464 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -112.5 1 +78.9 -97.1 +69.1 -85.1 13/16"NOM. Z m co Custom Size 36,131-38.463 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -111.7 +78.1 -96.1 +68.2 -84.0 GLASS STACK Custom Size 34.131-36.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -112.1 +78.4 -96.5 +68.5 -84.4 -I W 07 76" Standard Proview 30.994-34.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -113.0 +78.7 -96.9 +68.7 -84.5 AIRSPACE Q ai#il •�sa0 sauas Custom Size 30.131-30.993 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -115.2 +80.0 -99.0 +70.2 -86.4 3/16"TEMPERED GLASS Custom Size 28.131-30.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +8&0 -130.0 +80.0 1 -130.0 +80.0 -115.9 +80.0 -99.5 +70.4 -86.6 }}t I I I I I t l rF 31 74 Shortest 26.194*-28.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -117.9 +80.0 -101.3 +71.5 -88.0 L�` r� p L!pNiF�l A Equal-lite 42.464 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -110.4 +76.5 -94.2 +66.5 -81.8 v; ." ra%'x 84" Custom Size 38.131-42.463 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -110.1 +75.8 -93.3 +65.5 -80.6 25 0R 56 1/2"NOM. .` ��``, �,t =fS '•. !, Standard Proview 34.194*-38.130 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -130.0 +80.0 -111.1 +76.8 -94.5 +66.3 -81.6 GLASS BITE EXTERIOR o. 58705 *MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-49.391 7+ - MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-48.391 MINIMUM SASH HEIGHT FOR FLANGED,RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-49.806 70-73 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG,RADIUS TOP WINDOWS IS:BUCK HEIGHT-48.806 ;441 35 OR 56 GLASS TYPE 8 = ,AT " ' '� r �^ •'•.'°C��z'���.••' ,\tea 1)TIP TO TIP DIMENSIONS SHOWN.FOR INTEGRAL FIN AND EQUAL-LEG WINDOWS,SUBTRACT 1"FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. 2)FOR SIZES NOT SHOWN,ROUND UP TO THE NEXT AVAILABLE SIZE. 3)FOR RADIUS TOP WINDOWS, FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. A.LYNN MILLER,P.E. 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF+65 PSF.NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. P.E.#58705 TABLE 6: Anchor Quantities Required for Tip to Tip Width "Through-Frame"Installation 18" 1 25" 33" 1 37" 41" 45" 49" 53-1/8" u ing Glass Ty es 1-3 Jamb Jamb Jamb Jamb Jamb Jamb Jamb Jamb m m o o iv Q 0 Bottom Sash a g g o g 2 o g v g o 2 v g o g a Sash Height � Description 3 p Range(in) 'o for Given Range n a� s a� a a� a� Q a� a� m TABLE 6b: Q m ¢ m ¢ m ¢ m ¢ m Q m ¢ m ¢ m 24" Equal-lite 12.464 1 2 1 1 2 1 1 2 1 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 Type Description(Listed from Exterior to Interior) Equal-lite 15.964 1 2 1 1 2 1 1 2 1 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1** 1/8"Annealed 31" Standard Proview 12.994-15.963 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 3 2 2 2 2 13/16'IG: 1/8"Annealed Cap,Airspace, 1/8"Annealed Shortest 12A64-12.993 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3/16"Annealed Equal-lite 19.652 2 2 1 2 2 1 2 2 1 2 2 2 2 2121 2 2 2 2 2 2 2 2 2 **TIP TO TIP SIZE FOR WINDOW USING GLASS TYPE 1 IS Standard Proview 15.944-19.651 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 LIMITED TO 53-1/8"X 76". 38-3/8" Custom Size 15.131-15.943 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Custom Size 14.131-15.130 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Shortest 12.464-14.130 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 A) NO CHANGES THIS Equal-lite 22.964 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 SHEET. Custom Size 20.131-22.963 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 g Standard Proview 18.594-20.130 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 46 Custom Size 16.131-18.593 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 JR - 03/11/20 Custom Size 15.131-16.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Custom Size 14.131-15.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Shortest 12.464-14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Y Q Equal-lite 24.964 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 W P naa Custom Size 22.131-24.963 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 0' 0 Standard Proview 20.194-22.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 0 O O 49' Custom Size 18.131-20.193 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 } ti a}op 0 Q Custom Size 16.131-1&130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 J M Z z Custom Size 14.131-16.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Shortest 12.464-14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Z D- � CD Z Equal-lite 25.777 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 = W a Custom Size 24.131 -25.776 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 W U 0 J uMojp 'ON F Standard Proview 20.844-24.130 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 F- W ^ Q DMo a Custom Size 20.131-20.843 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 ti > f- i= 50-5/8" Custom Size 18.131-20.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Z Z Custom Size 16.131-18.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 W N J � Custom Size 14.131-16.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Z m LL Shortest 12.464-14.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 H 0 Equal-lite 31.964 2 3 1 2 3 1 2 3 1 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 *GLASS TYPE 1: W O Custom Size 28.131-31.963 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-37.536 N J Standard Proview 25.794-28.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-36,536 ` 0 Z as Custom Size 24.131-25.793 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 MINIMUM SASH HEIGHT FOR FLANGED,RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-37.951 Z 4S MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG,RADIUS TOP WINDOWS IS:BUCK HEIGHT-36.951 0 � � 63' Custom Size 22.131-24.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Q Q Custom Size 20.131-22.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 *GLASS TYPE 2&3: W O Custom Size 18.131-20.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-49.391 Z 0 O MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-48.391 0 _ � Custom Size 16.131-18.130 3 2 1 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 MINIMUM SASH HEIGHT FOR FLANGED,RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-49.806 C) = Shortest 13.194*-16.130 4 2 1 4 2 1 4 2 1 4 2 2 4 2 2 4 2 2 4 2 2 4 2 2 MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG,RADIUS TOP WINDOWS IS:BUCK HEIGHT-48.806 JQ Z U) Equal-lite 38.464 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 Custom Size 36.131-38.463 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 al}l �sa4 sauas Custom Size 34.131-36.130 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 76" Standard Proview 30.994-34.130 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 ` i4=;`,{}+ # , Custom Size 30.131-30.993 3 3 1 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 r , Custom Size 28.131-30.130 3 311 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 Shortest 2&194*-28.130 4 2 1 4 2 1 4 2 1 4 2 2 4 2 2 4 2 2 4 2 2 4 2 2 a F,r0. 7 05 Equal-lite 42.464 3 4 1 3 4 1 3 4 1 3 4 2 3 4 2 3 4 21 3 4 2 3 4 2 84" Custom Size 38.131-42.463 3 4 1 3 4 1 3 4 1 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 1)TIP TO TIP DIMENSIONS SHOWN. FOR INTEGRAL FIN AND EQUAL-LEG WINDOWS,SUBTRACT 1"FROM , THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE. Standard ProJew 34.194*-38.130 4 3 1 4 3 1 4 3 1 4 3 2 4 3 2 4 3 2 4 3 2 4 3 2 2)FOR SIZES NOT SHOWN,ROUND UP TO THE NEXT AVAILABLE SIZE. IT� r�, - 3)FOR RADIUS TOP WINDOWS,FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. ,r/// I01 VAL 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF A.LYNN MILLER,P.E. +65 PSF.NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. P.E.#58705 TABLE 7: Anchor Quantities Required for Tip to Tip Width "Through-Frame"Installation 18" 25" 33" 37" 41" 46- 1 49" 53-1/8" u ing Glass Ty s 4-8 Jamb Jamb Jamb Jamb Jamb Jamb Jamb Jamb or h5 Bottom Sash v oa oo g g a a a g o g v Sash Height y (D o a0i o a) o '� o iu o Description > o = ' o = > o = > o = ' o = > o = > o = > o = Range(in) 0 0 0 0 0 0 for Given Range o a� .fl @ -8 a) .o a� n o o a� a� n a� TABLE 7b: m ¢ m ¢ m ¢ m ¢ m ¢ m ¢ m ¢ m 24" Equal-lite 12.464 1 2 1 1 2 1 1 2 1 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 Type Description(Listed from Exterior to Interior) Equal-lite 15.964 1 2 1 1 2 1 1 2 1 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 4 13/16"IG;3l16"Annealed Cap,Airspace, 3/16"Annealed 31" Standard Proview 12.994-15.963 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 3 2 2 2 5 1/8"Tempered Shortest 12.464-12.993 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 6 13116'IG: 1/8"Tempered Cap,Airspace, 1/8"Tempered Equal-lite 19.652 2 2 1 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 3 2 2 3 2 7 3116"Tempered Standard Prmhew 15,944-19.651 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 8 13116"IG:3/16"Tempered Cap,Airspace,3/16"Tempered 38-3/8" Custom Size 15.131-15.943 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 Custom Size 14.131-15.130 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 Shortest 12.464-14.130 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 2 2 3 A) NO CHANGES THIS Equal-lite 22.964 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 2 3 2 SHEET. Custom Size 20.131 -22.963 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 2 3 2 2 Standard Provew 18.594-20.130 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 2 3 3 45" Custom Size 16.131-18.593 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 2 2 3 JR-03/11/20 Custom Size 15.131-16.130 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 3 2 3 3 2 3 Custom Size 14.131-15.130 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 3 2 2 3 2 3 3 2 3 Shortest 12.464-14.130 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 3 2 3 00 Y Q Equal-lite 24.964 2 2 1 2 2 1 2 2 2 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 w Custom Size 22.131 -24.963 2 2 1 2 2 1 2 2 2 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 0 naa Standard Proview 20.194-22.130 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 3 2 2 3 3 2 3 3 O O 49" Custom Size 18.131-20.193 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 3 3 2 3 3 3 2 3 3 �- � a}Dp Q Custom Size 16.131-18.130 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 3 2 3 U) Z Custom Size 14.131-16.130 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 3 2 3 O J O Z O t Shortest 12.464-14.130 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 3 2 3 Z � Equal-lite 25.777 2 2 1 2 2 1 2 2 2 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 = LL Z X8 r a Custom Size 24.131-25,776 2 2 1 2 2 1 2 2 2 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 W U 00 J uMo�Q 'ON o Standard Proview 20.844-24.130 2 2 1 2 2 1 2 2 2 2 2 2 2 3 2 2 3 2 2 3 2 2 3 2 H W Q SMO a Custom Size 20.131-20.843 2 2 1 2 2 1 2 2 2 2 2 2 2 2 2 2 3 2 2 3 3 2 3 3 0 � 1-- F 50-5/8" Custom Size 18.131 -20.130 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 3 3 3 2 3 Z 0) Z Custom Size 16.131 -18.130 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 3 2 3 W Custom Size 14.131-16.130 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 3 2 3 Z m LL Shortest 12.464-14.130 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 3 2 3 3 2 3 3 2 3 � H O _ t` Equal-lite 31.964 2 3 1 2 3 1 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 w Custom Size 28.131-31.963 3 3 1 3 3 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 ® C J Standard Proview 25.794-28.130 3 2 1 3 2 1 3 3 2 3 3 2 3 3 2 3 3 2 3 3 2 3 3 3 Z Z }aayS Custom Size 24.131-25.793 3 2 1 3 2 1 3 2 2 3 3 2 3 3 2 3 3 3 3 3 3 3 3 3 ZO 63" Custom Size 22.131 -24.130 3 2 1 3 2 1 3 2 2 3 2 2 3 3 2 3 3 3 3 3 3 3 3 3 (- Custom Size 20.131-22.130 3 2 1 3 2 1 3 2 2 3 2 2 3 2 2 4 3 3 3 3 3 3 2 3 o Custom Size 18.131-20.130 3 2 1 3 2 1 3 2 2 3 2 2 4 2 2 4 2 3 4 2 3 3 2 3 Z CO Custom Size 16.131-18.130 3 2 1 3 2 1 3 2 2 4 2 2 4 2 2 4 2 3 4 2 3 4 2 3 w U = Shortest 13.194*-16.130 4 2 1 4 2 1 4 2 2 4 2 2 4 2 2 4 2 3 4 2 3 4 2 3 J Z (n Equal-lite 38.464 3 3 1 3 3 1 3 3 2 3 4 2 3 4 2 3 4 2 3 4 2 3 3 2 Q Q Custom Size 36.131 38.463 3 3 1 3 3 1 3 3 2 3 4 2 3 4 2 3 4 2 3 4 2 3 3 2 al}Il asap sauas Custom Size 34.131 -36.130 3 3 1 3 3 1 3 3 2 3 3 2 3 4 2 3 4 2 3 3 2 3 3 2 ! " 76" Standard Proview 30.994-34.130 3 3 1 3 3 1 3 3 2 3 3 2 4 4 2 3 3 2 3 3 2 3 3 2 Custom Size 30.131 -30.993 3 3 1 3 3 1 3 3 2 3 3 2 4 3 2 4 3 2 3 3 2 3 3 3 , 1' Custom Size 28.131-30.130 3 3 1 3 3 1 3 3 2 4 3 2 4 3 2 4 3 2 3 3 3 3 3 3 Shortest 26.194*-28.130 4 2 1 4 2 1 4 3 2 4 3 2 4 3 2 4 3 2 4 3 3 4 3 3 `JU5 ° Equal-lite 42.464 3 4 1 3 4 1 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 "a 84" Custom Size 38.131 -42.463 3 4 1 3 4 1 3 4 2 3 4 2 4 4 2 3 4 2 3 4 2 3 4 2 1)TIP TO TIP DIMENSIONS SHOWN. FOR INTEGRAL FIN AND EQUAL-LEG WINDOWS,SUBTRACT 1"FROM THE TIP TO TIP DIMENSION IN THE TABLE TO DETERMINE THE WINDOW SIZE, Standard Proview 34.194*-38.130 4 3 1 4 3 1 4 3 2 4 4 2 4 4 2 4 4 2 414 2 4 3 2 ° *MINIMUM SASH HEIGHT FOR FLANGED WINDOWS IS:TIP TO TIP HEIGHT-49.391 2)FOR SIZES NOT SHOWN,ROUND UP TO THE NEXT AVAILABLE SIZE. m°'.° AT GF MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG WINDOWS IS:BUCK HEIGHT-48.391 MINIMUM SASH HEIGHT FOR FLANGED, RADIUS TOP WINDOWS IS:TIP TO TIP HEIGHT-49.806 3)FOR RADIUS TOP WINDOWS,FIND THE SMALLEST WINDOW SIZE IN THE TABLE ABOVE WHICH THE 'oJ � ' / > MINIMUM SASH HEIGHT FOR INTEGRAL FIN AND EQUAL LEG,RADIUS TOP WINDOWS IS:BUCK HEIGHT-48.806 RADIUS TOP WINDOW WILL COMPLETELY FIT WITHIN. //Idi OO 4)WINDOWS WITH THE LOW SILL OPTION ARE LIMITED TO A MAXIMUM POSITIVE DESIGN PRESSURE OF A.LYNN MILLER,P.E. +65 PSF.NEGATIVE DESIGN PRESSURES ARE UNAFFECTED. P.E.#58705 INSTALLATION DETAILS FOR FLANGE FRAMES INSTALLATION OPTION 2 INSTALLATION OPTION 3 INSTALLATION ANCHORED THROUGH FRAME ANCHORED THROUGH FRAME AND 1X OPTION 1 EDGE DISTANCE - �--- DIRECTLY INTO CONCRETE/CMU. BUCKSTRIP INTO CONCRETE/CMU. ANCHORED THROUGH— ----- i EMBEDMENT SEE NOTE 2,THIS SHEET. EMBEDMENT FRAME INTO 2X WOOD 1/4"MAX SHIM 1/4"MAX SHIM FRAME OR BUCKSTRIP. ; SEE NOTE 2,THIS SHEET. I I C— EMBED- I Q a 4 SASH VISIBLE 17 e°• EDGE MENT EDGE m LIGHT WIDTH DISTANCE DISTANCE 1/4"MAX SHIM 26 L-- ----�--J FIXED VISIBLE LIGHT WIDTH 1 SEE TABLE ° NOTE B,FOR 30 18 HEAD TYPE <.° A) REVISED ANCHOR TYP.ANCHOR TYPE, 44 TYPE TABLE. FIXED EMBEDMENTAND 2 VISIBLE EDGE DISTANCE PER LIGHT SUBSTRATE,SEE 31 5 OR 56 • JR- 03/11/20 HEIGHT TABLE 8. TIP TO TIP WIDTH TYP.ANCHO\TYPE, 32 EMBEDME oQ EXTERIOR EDGE DISTAN W fn TYP.ANCHOR TYPE, HORIZONTAL SECTION A-A > 45 EMBEDMENT AND EDGE SUBSTRATE,SEE � DISTANCE PER SUBSTRATE, TABLE 8: 0 0 14 SEE TABLE 8. -�-{ 1/4"MAX.SHIM N a}Dp 0 Q VISIBLE LIGHT FORMULAS: O v' O 46 55 DADE APPROVED MULLION,FBC (SHOWN FOR HI-RISE SILL;SEE -� J p Z Zp COMPLIANT ALUMINUM/STEEL FRAMING SHEET 10 FOR STANDARD SILL) Z W �. 43 OR STEEL STUD.MAY BE VERTICAL OR TIP 13 HORIZONTAL.SEE SUBSTRATE WIDTH U W 6 Z � e TO PROPERTIES,TABLE 8. SASH&FIXED LITE:TIP TO TIP WIDTH-5A2" W U 00 J UMDJQ 'IN TIP 63 USE EITHER 1 @ F. Z IT J 0Ma HEIGHT SWEEP LATCH @ O W Q MIDSPAN OR 2 HEIGHT(EQUAL-LITE) o > BOTTOM LOCKS INSTALLATION TIP TO TIP HEIGHT/2-3.73" Z Z OPTION 4 SASH HEIGHT(PROVIEW) ANCHORED THROUGH z W VISIBLE FRAME INTO METAL @FIXED LITE:TIP TO TIP HEIGHT/2+3.78" O LIGHT @SASH:TIP TO TIP HEIGHT/2-11.93" 2 ap HEIGHT ® rn J O HEIGHT(CUSTOM SASH) rn @FIXED LITE:TIP TO TIP HEIGHT-SASH HEIGHT-3.55" !� Z V }aays TABLE 8: @SASH:SASH HEIGHT-4.60" ZO W Min. Edge Min. ~ SL EXTERIOR Anchor Substrate X Q Distance Embedment = W o 33 P.T. Southern Pine(SG=0.55) 9/16" 1-3/8" NOTES: Z (9 (4 10 #12 Steel � Z p- , 15 Aluminum, 6063-T5 min. 3/8" 0.063" W _ 18-8 or 410 1)USE ONLY SUBSTRATE-APPROPRIATE ANCHORS LISTED ON J (n OPTIONAL HI-RISE SS Screw A36 Steel 3/8" 0.063" TABLE 8.FOLLOW EMBEDMENT AND EDGE DISTANCE LIMITS.ANY Q LL SILL SHOWN.SEE Steel Stud, Gr. 33 min. 3/8" 0.045"(18 Ga) INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF al}�l osap sauaS 1"WEEP 42 SHEET 10 FOR Concrete(min. 3.35 ksi) 1" 1-3/4" THE WINDOW. ; NOTCH AT STANDARD SILL. 1/4"410 SS Un routed CMU, ASTM C-90 2-1/2" 1-1/4" �,yl. "; - CreteFlex 9 ( ) i 1�f/11 EACH END 2)MASONRY ANCHORS MAY BE USED INTO WOOD AS PER TABLE z` ... . f 1/4"MAX. P.T. Southern Pine(SG=0.55) 1" 1-318" ..' ' YQ 8.ALL WOOD BUCKS LESS THAN 1-1/2"THICK ARE TO BE t P ,N i �✓A, FS HIM Concrete(min.2.85 ksi) 1" 1-3/8" CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL 1/4"Steel Ungrouted CMU, (ASTM C-90) 2-1/2" 1-1/4" IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE.WOOD BUCKS Ultracon = q fc�. 5970a P.T. Southern Pine(SG=0.55) 1" 1-3/8" DEPICTED AS 2X ARE 1-1/2"THICK OR GREATER.1X AND 2X BUCKS - - ° • ° Concrete(min.3.00 ksi) 1-3/16" 1-3/8" (WHEN USED)SHALL BE DESIGNED TO PROPERLY TRANSFER ;�r n e° ' 9/4"Steel LOADS TO THE STRUCTURE.WOOD BUCK DESIGN AND NO ANCHORS ) ° Ultracon+ Ungrouted CMU, (ASTM C-90) 1-1/2" 1-1/4" INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR 40 REQUIRED IN • P.T. Southern Pine(SG=0.55) 1" 1-3/8" ARCHITECT OF RECORD. 1' �7E OF ' FLANGE OR ° i tti EQUAL-LEG A)MIN.OF 3 THREADS BEYOND THE METAL SUBSTRATE. °• �� ti'� '.�� FRAME SILLS B)USE ONLY FLATHEAD ANCHORS IN JAMBS.PAN/HEX/FLAT HEAD TYPE IS 3)VISIBLE LIGHT WIDTH OR HEIGHT(ALSO REFERRED TO AS �l 11(� ��• `�, ALLOWABLE FOR ANCHORS IN THE HEAD. DAYLIGHT OPENING)IS MEASURED FROM BEADING TO BEADING. />// NAL `�voe VERTICAL SECTION B-B C)"UNGROUTED CMU"VALUES MAY BE USED FOR GROUTED CMU APPLICATIONS. A.LYNN MILLER,P.E. P.E.#58705 INSTALLATION DETAILS FOR EQUAL-LEG FRAMES INSTALLATION OPTION 2 INSTALLATION OPTION 3 INSTALLATION ANCHORED THROUGH FRAME ANCHORED THROUGH FRAME AND 1X DIRECTLY INTO CONCRETE/CMU. BUCKSTRIP INTO CONCRETE/CMU. OPTION 1 EDGE DISTANCE — ------ SEE NOTE 2,THIS SHEET. ANCHORED THROUGH r --- T--� EMBEDMENT FRAME INTO 2X WOOD —� EMBEDMENT FRAME OR BUCKSTRIP. 1/4"MAX SHIM 1/4"MAX SHIM —►) I®-- ° ,. SEE NOTE 2,THIS SHEET. EMBED- I SASH VISIBLE 17 EDGE MENT EDGE ,. �'. LIGHT WIDTH DISTANCE DISTANCE < 1/4"MAX SHIM 19 26 FIXED VISIBLE ---- ° I--- 1----1 °` '� i--- -- I LIGHT WIDTH SEE TABLE 3 NOTE B,FOR •` . a e 30 18 HEAD TYPE A) REVISED ANCHOR FIXED TYP.ANCHOR TYPE, 44 TYPE TABLE. EMBEDMENTAND e °a. \TYPE, N LIGHT EDGE DISTANCE PER SUBSTRATE,SEE JR - 03/11/20 HEIGHT 31 5 OR 5B 6 TABLE 8. ® BUCK WIDTH — I TYP.ANCHO32 EXTERIOR EMBEDME WT_ Y Q TYP.ANCHOR TYPE, HORIZONTAL SECTION A-A EDGE DISTAN > > 45 EMBEDMENT AND EDGE 107 SUBSTRATE,SEE W O > gab DISTANCE PER SUBSTRATE, TABLE 8. a U) 14 SEE TABLE 8. U') a;DQ W ¢ 1/4"MAX.SHIM VISIBLE LIGHT FORMULAS: O cl' O 46 55 (SHOWN FOR HI-RISE SILL;SEE 0 J p Z O 43 SHEET 10 FOR STANDARD SILL) LL CD DADE APPROVED MULLION,FBC = W T Z Xa ~ BUCK 13 COMPLIANT ALUMINUM/STEEL FRAMING WIDTH U U p 11MDJQ HEIGHT 63 USE EITHER 1 OR STEEL STUD.MAY BE VERTICAL OR @SASH&FIXED LITE: BUCK WIDTH-4.12" z 00 Q 9Ma SWEEP LATCH @ HORIZONTAL.SEE SUBSTRATE p W MIDSPAN OR 2 PROPERTIES,TABLE 8. HEIGHT(EQUAL-LITE) o U) BOTTOM LOCKS BUCK HEIGHT/2-3.23" Z Z — N INSTALLATION CD SASH HEIGHT(PROVIEW) LL VISIBLE EQUAL OPTION 4 @FIXED LITE:BUCK HEIGHT/2+4.28" Z) ZO O LIGHT LEG/BOX ANCHORED THROUGH @SASH:BUCK HEIGHT/2-11.43" 2 p HEIGHT FRAME FRAME INTO METAL SHOWN HEIGHT(CUSTOM SASH) N W @FIXED LITE: BUCK HEIGHT-SASH HEIGHT-2.55" Z U) }aa4S @SASH:SASH HEIGHT-4.60" ZO X EXTERIOR TABLE 8: 2 W Q Anchor Substrate Min. Edge Min. 33 Distance Embedment NOTES: Q 15 12 P.T. Southern Pine(SG=0.55) 9/16" 1-3/8" w Z Aluminum, 6063-T5 min. 3/8" _ #12 Steel, 0.063" 1)USE ONLY SUBSTRATE-APPROPRIATE ANCHORS LISTED ON J O U) OPTIONAL HI-RISE 18-8 or 410 TABLE 8.FOLLOW EMBEDMENT AND EDGE DISTANCE LIMITS.ANY Q W SILL SHOWN.SEE Aud Gr. 33 min 3/8" 0Steel 3/8" 0.045" (063" INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF al;i� •Dsaa sauaS 1"WEEP 42 SS Screw Steel Stud SHEET 10 FOR , . . . 18 Ga ) THE WINDOW. NOTCH AT STANDARD SILL. Concrete(min. 3.35 ksi) 1" 1-3/4" EACH END 1/4"410 SS Ungrouted CMU, (ASTM C-90) 2-1/2" 1-1/4" 2)MASONRY ANCHORS MAY BE USED INTO WOOD AS PER TABLE v �{ L 1/4"MAX. CreteFlex 8.ALL WOOD BUCKS LESS THAN 1-1/2"THICK ARE TO BE ✓ : .° °" y °r SHIM P.T. Southern Pine(SG=0.55) 1" 1-3/8" :v1-Efv o CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL ' r , Concrete(min. 2.85 ksi) 1" 1-3/8" IF UNIT IS INSTALLED DIRECTLY TO SUBSTRATE.WOOD BUCKS z ` 1/4"Steele, 537[75 Ultracon Ungrouted CMU, (ASTM C-90) 2-1/2" 1-1/4" DEPICTED AS 2X ARE 1-1/2"THICK OR GREATER.1X AND 2X BUCKS ®_ ° a WHEN USED SHALL BE DESIGNED TO PROPERLY TRANSFER — NO ANCHORS P.T. Southern Pine(SG=0.55) 1" 1-3l8" { ) REQUIRED IN a 4 Concrete(min. 3.00 ksi) 1-3/16 1-3/8" LOADS TO THE STRUCTURE.WOOD BUCK DESIGN AND FLANGE OR 1/4"Steel INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ); EQUAL-LEG ° °a Ultracon+ Ungrouted CMU, (ASTM G-90) 1-1/2" 1-1J4" ARCHITECT OF RECORD, iF�TE OF : FRAME SILLS P.T. Southern Pine{SG=0.55) 1" 1-3/8" gjr i_ ° a e 3)VISIBLE LIGHT WIDTH OR HEIGHT(ALSO REFERRED TO AS A)MIN.OF 3 THREADS BEYOND THE METAL SUBSTRATE. rrr` `�� ••••'•Y,m ,y C���,'�` B)USE ONLY FLATHEAD ANCHORS IN JAMBS.PAN/HEX/FLAT HEAD TYPE IS DAYLIGHT OPENING)IS MEASURED FROM BEADING TO BEADING. °r`d 1,11�/ L t VERTICAL SECTION B-B ALLOWABLE FOR ANCHORS IN THE HEAD. C)"UNGROUTED CMU"VALUES MAY BE USED FOR GROUTED CMU APPLICATIONS. A.LYNN MILLER,P.E. P.E.#58705 INSTALLATION DETAILS FOR INTEGRAL FIN FRAMES EDGE EDGE DISTANCE DISTANCE EMBEDMENT -�- — O O EDGE DISTANCE 1/4"MAX SHIM 1/4"MAX SHIM 5 ( SASH VISIBLE 17 --_-- LIGHT WIDTH EMBEDMENT 19 26 �1/4"MAX EMBEDMENT FIXED VISIBLE 2 SHIM LIGHT WIDTH 30 18 TYP.ANCHOR TYPE, A) NO CHANGES THIS EMBEDMENT AND EDGE SHEET. FIXED DISTANCE PER SUBSTRATE, 44 ° VISIBLE SEE TABLE 9. LIGHT JR -03/11/20 zir 56 �k� HEIGHT I _ 5 OR 5 BUCK WIDTH 32 TYP.ANCHOR TYPE, o Y Q HORIZONTAL SECTION C-C EMBEDMENTANDEDGE j =8 45 DISTANCE PER SUBSTRATE,SEE W Q TABLE 9.(NAIL SHOWN) t] O U) DADE APPROVED MULLION,FBC y a}n4 O Q COMPLIANT ALUMINUM/STEEL FRAMING Q N W 14 1!4"MAX.SHIM OR STEEL STUD.MAYBE VERTICAL OR Q m (n z HORIZONTAL.SEE SUBSTRATE J J O Z O PROPERTIES,TABLE 9. Q W O W O 43 VISIBLE LIGHT FORMULAS: z (0 -) m (SHOWN FOR STANDARD SILL;SEE (=j W O' Z umo ~ BUCK 13 SHEET 8 OR 9 FOR HI-RISE SILL) W - 00 J Q 'ON HEIGHT 63 USE EITHER 1 #10 OR#12 STEEL F- W Q 9Ma SWEEP LATCH @ SELF DRILLING WIDTH O > �- MIDSPAN OR 2 46 55 @ SASH&FIXED LITE:BUCK WIDTH-4.12" p d U) BOTTOM LOCKS SMS(G5),SEE TABLE 9. Z z CV HEIGHT(EQUAL-LITE) `- SASH BUCK HEIGHT/2-3.23" Z O u- VISIBLE INSTALLATION = U o LIGHT HEIGHT(PROVIEW) HEIGHT OPTION 7 @FIXED LITE: BUCK HEIGHT/2+4,28" ® N J ANCHORED THROUGH @SASH:BUCK HEIGHT12-11.43" ca'v 0 ' k X }aa4S INTEGRAL FIN INTO METAL Z Z_ z HEIGHT(CUSTOM SASH) O_ U) 16 STANDARD SILL @FIXED LITE:BUCK HEIGHT-SASH HEIGHT-2.55" EXTERIOR SHOWN.SEE @SASH:SASH HEIGHT-4.60" Q LL- 33 SHEET 9 FOR C7 (D ti 42 $ OPTIONAL HI-RISE Z) H U) 1"WEEP SILL. -j NOTCH AT TABLE 9: Q z EACH END Anchor Substrate Min. Edge Min. al}l • ap aauaS 1/4"SHIM MAX Distance Embedment NOTES: as SHIM 2-1/2"x.113"Box Nail P.T. Southern Pine(SG=0.55) 5/16" 2.438 �4 Ili I r °/ �j f 1)USE ONLY SUBSTRATE APPROPRIATE w L, r' rr 2-1/2"x.131"Common Nail P.T. Southern Pine(SG=0.55) 3/8' 2.438 ti ``.`•••... P� rr T ANCHORS LISTED ON TABLE 8.FOLLOW . 4 2-1/2"x.145"Roofing Nail P.T. Southern Pine(SG=0.55) 3/8" 2.438 EMBEDMENT AND EDGE DISTANCE LIMITS.ANY °'•;' , 2-1/2"x.145"Roofing Nail P.T. Southern Pine(SG=0.55) 3/8" 2.438 INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF THE WINDOW. = No. 58705 TYP.ANCHOR TYPE, �� P.T. Southern Pine(SG=0.55) 1/2" 1.375 a EMBEDMENT AND EDGE - EDGE DISTANCE #10 Steel Trusshead Screw or 0.125"Aluminum, 6063-T5 min. 5/16" 0.090 2)VISIBLE LIGHT WIDTH OR HEIGHT(ALSO DISTANCE PER SUBSTRATE, _ - #12 Steel, 18-8 or 410 SS SEE TABLE 9. 0.050"A36 Steel 5/16" 0.050 REFERRED TO AS DAYLIGHT OPENING)IS41AT EMBEDMENT Screw MEASURED FROM BEADING TO BEADING. rF /`(SCREW SHOWN) 0.045" (18 Ga) Steel Stud, Gr. 33 ruin. 5/16" 0.0450 m-e , VERTICAL SECTION D-D A)MIN.OF 3 THREADS BEYOND THE METAL SUBSTRATE. rr .. r �, s . /VF A Ln °''11 ! 1ik�' A.LYNN MILLER,P.E. P.E.#58705 2.560" 3.185" 2.060" -►i 2.848" 2.848" �-�- .062" 1.125" n n A I'l n [n 2.848" 062" 062" i ] 062" 2.112" T 2.724" 2.724" 2.724" 1.489" �1 987" 1.125" .062"7 .062" .062" O FLANGE FRAME HEAD O HEAD INTEGRAL FIN FRAME O EQUAL LEG FRAME HEAD O FLANGE FRAME JAMB O INTEGRAL FIN FRAME O EQUAL LEG FRAME JAMB JAMA) NO CHANGES THIS 2.798" - 2.798" 2.798" SHEET. I g N 2.798" - 2.798" ►I 2.798" JR- 03/11/20 ao Q Y 3.008" W T 2.841" 3.466" 2.341" 3.508" 4.133" O naa O (n .062" .062" 062" .062" .062" -®- .062" N atop 0! LL f OO ZZ u- WO ZZ = LLI Z 1.125" 1.125" O~ U U O uMo p O 00 FLANGE FRAME SILL Os EQUAL LEG FRAME SILL �a LI HL HI-RISE E FRAME SILL 12 SIQLL UAL HI-RISELEGFRAME H W Q 9Mp INTEGRAL FIN f ~ O FRAME SILL �� INTEGRAL FIN FRAME 0 Z Z 2.273" -►) O SILL-HI-RISE - N C� LL 1.300" SILICONE HOT-MELT BUTYL co = v W STRUCTUL J POLYISOBUTYLENE 1/4"NOM. STRUCTURAL 3/16"NOM. N (7 170" 2.772" WITH SILICONE Z Z }aags DESICCANT FOAM WITH p U) 2.211" 2.105" DESICCANT Z 2.150" O Q 062" +- .062" EXT.GLASS � z O EXT.GLASS (7 uj INT.GLASS INT.GLASS J X U) .062" ---®� �-- -. ( 1.300" 1.300" I-f- Q W 70 KODISPACE 4SG TPS 71 SUPER SPACER®NXT TM al}!1 •asap sauas 13 SASH TOP RAIL is FIXED MEETING RAIL SASH BOTTOM RAIL- �s SASH BOTTOM RAIL ttitl� •=' , ALUMINUM POLYISOBUTYLENE DESICCANT FILL REINFORCEMENT ` �-�- 1.446" SEAL 5/16"NOM. '•; . �.465" ���►►►--- SILICONE SEALS 1.522" -►�� --�-� .6 4" .773" 1 ROLL-FORMED y- ,, 587 a5 040" i-L BUTYL& STAINLESS STEEL 062" 627" E;7 " DESICCANT - 1.235" 040" .802" 802" .813" FOAM �� 1 �� - II - EXT.GLASS EXT.GLASS . Y�� .y O 1.370" '1!1.300" 07 045" ' ` ?`.? :'" INT.GLASS �, U r-; HEAD ANCHOR INT.GLASS ref p o,\ �7 SASH SIDE RAIL 18 COVER �s SASH STOP COVER zs IG BEAD 2s6 IG SNAP BEAD zs 1/8"&3/16"BEAD ® Tm 72 DURASEAL SPACER 73 XL EDGE SPACER S A.LYNN MILLER,P.E. P.E.#58705 TABLE 11: Item PGT Part# Description Material 51 ASSEMBLY DETAILS FOR 1 642001 Head, Flange Alum. 6063-T6 FLANGE FRAMES 2 642017 Head, Integral Fin Alum. 6063-T6 (OTHER FRAME TYPES SIMILAR). 3 624028 Head, Equal-leg Alum. 6063-T6 a 4 624004 Jamb, Flange Alum. 6063-T6 4 4A Jamb, Flange(Used For Alternate Radius Top Head) Alum. 6063-T52 1 5 624020 Jamb, Integral Fin Alum. 6063-T6 51 5A Jamb, Integral Fin (Used For Alternate Radius Top Head) Alum. 6063-T52 6 624031 Jamb, Equal-leg Alum. 6063-T6 oo 6A Jamb, Equal-leg(Used For Alternate Radius Top Head) Alum. 6063-T52 40 HEAD 7 624002 Sill, Flange Alum. 6063-T6 8 624018 Sill, Integral Fin Alum. 6063-T6 INTERIOR 9 624029 Sill, Equal-leg Alum. 6063-T6 41 10 624003 Sill, Hi-Rise, Flange Alum. 6063-T6 JAMB A) ADDED BA , 11 624019 Sill, Hi-Rise, Integral Fin Alum. 6063-T6 o UPDATED MATTERIALERIAL ING 12 624030 Sill, Hi-Rise, Equal-leg Alum. 6063-T6 14 PROP. TABLE. 13 624006 Sash Top Rail Alum. 6005A-T61 4 14 624005 Fixed Meeting Rail Alum. 6005A-T61 INTERIOR JR-03/11/20 15 624012 Sash Bottom Rail-Hi-Rise Alum. 6063-T6 00 16 624068 Sash Bottom Rail Alum. 6063-T6 JAMB W ° Q 17 624007 Sash Side Rail Alum. 6063-T6 > o �aa 18 624051 Head Anchor Cover Alum. 6063-T6 0 FIXED MEETING RAIL o 0 19 624015 Sash Stop Alum. 6063-T6 � a}oQ O Q 25A 624009 IG Bead Alum. 6063-T5 O v O co 25B 624011 IG Snap Bead Alum. 6063-T5 J o Z Z 26 624023/24 1/8" & 3/16" Bead Alum. 6063-T6 ZZ u- � c S 30 6TP247 Glazing Bead, Bulb Vinyl for#624023 Vinyl SASH BOTTOM RAIL = LL - Z he ti 31 6TP248 Glazing Bead, Bulb Vinyl for#624009򘖋 Vinyl SASH W Z 00 J UM 'ON 32 724046 Sweep Latch (@ Top Rail) Cast Zinc 4 16 O W Q �nnQ 33 624049 Bottom Latch (@ Sill) Alum. 6063-T6 SIDE o > W 34 Setting Block (1/8"X 1/2"X4") Neoprene RAIL z Z cV 35A IG Setting Block (1/8"X3/4"X4") Neoprene JAMB 0 U) u 35B 724014 IG Snap Setting Block Vinyl Q O 36 724044 Bottom Rail Weatherstrip Extension ® to W I j N 37 724053 Sill Gasket Polyethylene 17 p 38 724054 Sash Top Rail Gasket Polyethylene * Z W 40a4s 39 724055 Sash Bottom Rail Gasket Polyethylene 37 0 cA Z 40 724057 Head Gasket Polyethylene 0 Q 41 724063 Meeting Rail Gasket Polyethylene Z U o 42 61226D Sash Bottom Rail Bulb Vinyl Polyethylene o 2 43 Weatherstrip, .270"X.187", Fin Seal (@ MR) INTERIOR R � O 44 67S16G Weatherstrip, .170"X.270", Fin Seal (@ Sash Side Rail) 39 Q m 45 Weatherstrip, .170"X.187", Fin Seal (@ Top Sash Rail) al?!1 •OsaQ sauas 46 varies Balance with Cover&Trim Rigid Vinyl s I"; 51 781 PSQX #8 X 1" PH SMS (Assembly) Stainless Steel ``yry � 4, 1 { TABLE 10:MATERIAL PROPERTIES USED 55 7834AA #8X34' Ph. PN SMS (Balance) Stainless Steel SILL 51 FOR ANCHORAGE CALCULATIONS: �' ;. ;,y� g 63 - Alum. Screen with Fiberglass Mesh Varies 7 Material Min. Fy Min. F„ =- 70 - Kommerling Kodispace 4SG TPS Steel Screw 92 ksi 120 ksi = No. 5'S705 See Sheet � 71 - Quanex Super Spacer nXT INTERIOR 18-8 Screw 60 ksi 95 ksi 11 for s 72 - Quanex Duraseal Spacer 410 Screw 90 ksi 110 ksi Materials �l 0 73 - Cardinal XL Edge Spacer Elco UltraCon® 155 ksi 177 ksi �� , 9 P 51 s: T- 74 - Dow 791, 899, 983 or GE 7700 Backbedding Silicone 1/4"DeWalt UltraCon+® 148 ksi 164 ksi NOTES: 410 SS Elco/Dewalt CreteFlex® 127.4 ksi 189.7 ksi 1)ALL CORNERS TO USE GASKET AND/OR SEALANT. 6063-T5 Aluminum 16 ksi 22 ksi °.°/ /'tr` b �4 A36 Steel 36 ksi 58 ksi I I t 2)SOME PARTS/OPTIONS NOT SHOWN ON DRAWING FOR CLARITY. Gr. 33 Steel Stud 33 ksi 45 ksi A.LYNN MILLER,P.E. P.E.#58705