Loading...
HomeMy WebLinkAboutA-2 2.24.21LIVINGGARAGELANAIENTRYTOTALLIVING C.F. = +/- 21,1662,1464762911323,045SQUARE FOOTAGEWWHR&S12'-8'' FLATCLG AFFREFmirror2x6 WALL R-11 INSULATION R-11 INSULATION22'' X 54''ATTIC ACCESSFIELD LOCATE9'-4'' FLAT CLGLANAIBATH 2ENTRY16' x 8' OHD2880 SC2880 PKT4080 BF 2 4080 BF 2 2880 28802080 BFB60D HBHB9'-4'' FLAT CLG AFF9'-4"23'-4"12'-612"19'-8"8"21'-0"52'-0"52'-0"13'-10"9080 (3) PNL SGD2'-9"2x4 BRG WALL 2x4 BRG WALLExterior Ceilings:1/2” min. thick stucco on 3/8” hi-rib lath attached to horizontaland/or vertical wood framing with nails or staples @ 8" o.c.to provide not less than 1-3/4” penetration into horizontal woodframing and 3/4” penetration into vertical wood framing membersPer ASTM C1063 and Stucco - ASTM C9262'-0"3'-0"3'-4" 28806'-6"22'-21 2"8'-6" 12'-71 2"23'-4"1'-6"3'-2"5'-0"3'-2"8'-4" 8" 22'-2"11'-91 2"10'-7"12'-11 2"8"3'-4"2'-1012"3'-312"3'-8"8'-1"3'-5"3'-5"2'-101 2"5'-61 2"8"8"3'-4"5'-0"2'-8"11'-8"8"8'-4"8"14'-012"3'-8"18'-1"8" 8"17'-71 2"4'-61 2"7'-91 2" 18'-31 2" 8'-5"8"2'-6"16'-0"2'-6"62'-0"8"10'-5 12"2'-3"8'-9"LINEN 2880 2'-4"2'-4"3'-11"1'-4"28'-8"1'-4"9'-0"3'-8"4'-8"43'-4"10'-4"5'-7"6'-4"4'-0"2'-4"4'-0"2'-4"1'-8"8'-8"2'-0"18'-3"3'-2"4"8"19'-11"13'-012"8"3'-11"2'-8"8"18'-5"8"10'-4"9"2'-6"9"8"1'-8"MICRO 1'-4"6'-8"1'-4"1'-4"8'-0"8'-0"10'-8"6'-4"2'-2"3'-2"4'-6"2'-6"5'-4"1'-0" 2'-0" 1'-8"1'-4"BEAM PKTBEAM PKT8'-4"2x4 BRG. WALLP2 POSTTOP @ 11'-5''GIRDERSIMPSON HTS20CONNECTED TOEACH TRUSS ALONGFRAMED BEARINGWALLS U.N.OPOST SCHEDULEP-3 POSTMARKSPECIFICATIONSTRUSS D1(2)HETA20GIRDER P1 POST1'-4"(2) 3080 SC1313SH 36SH 25 EGRESS 52880 2080 BF 3'-5"3'-10"2'-0"42" TALL KNEEWALLw/ CLEAR GLASSABOVETO CEILING(2) PERSONDECK MOUNTED(DROP IN) TUB9'-4'' FLAT CLGMASTERBATHMASTERSUITEPERIMETER FLAT CLG 9'-4"COFFER TO 10'-0"LIVINGROOMPERIMETER FLAT CLG 11'-4"COFFER TO 12'-0"3'-6"6'-1012"6'-8"6'-0"RANGEw/ HOOD312" STEP DN.20 MIN.FIRE RATEDSELF CLOSINGDOOR & FRAME7'-0 34"11'-11"4'-0" 2'-0"1'-6"5'-6"4'-6"P2 POSTTOP @ 11'-5''16'-1 12"71 2" 8"8'-2"3'-11 2"3'-9"8'-10" 7'-8"4'-8"8" 31 2" 1'-4"8" 8"8"8" 8"9'-8"8" 62'-0" 58'-0" 3'-4"13'-0" MFOYERVAULT TO 11'-4" FLAT CLG.DININGVAULT TO 11'-4" FLAT CLG.1'-4"4'-0"2'-8"3'-6"1'-0"5'-2"6'-1012"8"11'-31 2"8" (2) 2880 PANELS w/ SINGLE LITE CLEAR GLASS PR. 2880 BP P3 POSTTOP @ 9'-5"KITCHEN11'-4" FLAT CLG.DEN9'-4" FLAT CLG.BEDROOM 39'-4" FLAT CLG.BEDROOM 29'-4" FLAT CLG.LAUNDRY9'-4" FLAT CLG.2 CAR GARAGE9'-4" FLAT CLG. (ABOVE INTERIOR FIN. FLR.)SIMPSON HTS20CONNECTED TOEACH TRUSS ALONGFRAMED BEARINGWALLS U.N.O2x4 BRG. WALL DRYERVENTTO ROOF2880 PKT 28803080 KNEEWALLAND LEGSBELOW3'-2"5'-0"TYPE DESIGNATIONF = FILLED WITH GROUT / U = UNFILLEDGRAVITY LOAD8F16-1B/1TNOMINAL WIDTHNOMINAL HEIGHTADDED REBAR AT TOP OFQUANTITY OF #5 FIELDCOMPOSITE U-LINTEL FORUPLIFT LOADTOP OF COMPOSITE#5 FIELD ADDED REBAR ATU - LINTEL MIN. (1) REQ'D1-1/2" CLEARFIELD PLACED C.M.U.GROUT8" NOMINAL WIDTH7-5/8" ACTUALBOTTOM REINFORCING#5 FIELD ADDED REBAR ATPROVIDED IN U-LINTEL(SEE REINFORCING SCHEDULE)For a 5’-10” overall length U-lintel Type 8F16-1B/1T:Safe superimposed gravity load = 4360 PLFSafe superimposed uplift load = 2080 PLFSafe superimposed lateral load = 339 PLFBOTTOM OF U-LINTEL CAVITYBOTTOM OF U-LINTEL CAVITY FORQUANTITY OF #5 FIELD ADDED REBAR AT16" NOMINAL HEIGHT15-5/8" ACTUALBeamCompositeSafeGravityLoadAppliedGravityLoadSafeUpliftLoadAppliedUpliftLoad3'-0''<10003'-8''6113<5008F16-1B-1T4'-4"4'-6"4'-8"5'-6"5'-10"6'-2"7'-4"18437'-6"15687'-8"7'-8"8'-0"9'-0"14'-6"17'-4"19'-4"10'-4"10'-8"12'-8"PRESTRESSED8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1TPRESTRESSED8F24-1B-1TPRESTRESSED8F16-1B-1T61136113611361131370950750<1000<1000<1000<1000<1000<1000<1000<1000<1000<1000<1000<1000<1000<1000<1000<1000<1000<1000<1000<100035243060<500<500<500<500<500<500<500<500<500<500<500<500<500<500<500<500<500<500<500<500CASTCRETE PRECASTLINTEL SCHEDULE40534827072707270722762080208018681624162410721136113611369168006070536543604360348026612661184318431533136610754'-0"456123101112789131718191415162021<1000<500<1000<50022234'-4"10'-0"8F8-1B-1T8F8-1B-1T218964312075302425<1000<50010'-8"8F8-1B-1T<1000<5008F8-1B-1T8'-0"7255825904742614'-0"8F16-1B-1T<1000<50010025591915PCL + 2 COURSE BLK ABOVESET BOTT. @ 10-9"TOP BRG @ 12'-9"PCL + 5 COURSE BLK ABOVESET BOTT. @ 9-5"TOP BRG @ 12'-9"5'-4"8F16-1B-1T<1000<50053652276278F16-1B-1T<1000<5008'-8"11361843288'-4"8F16-1B-1T<1000<500113618432919'-4"8F16-1B-1T<1000<500113618433016PCL + 5 COURSE BLK ABOVESET BOTT. @ 9-5"TOP BRG @ 12'-9"211158"1' - 8 "8"1 1 58 "1'-4"TYP. ALL PIERSSET TOP(S) @ 12'-9''7PCL + 5 COURSE BLK ABOVESET BOTT. @ 9-5"TOP BRG @ 12'-9"926PCL + 2 COURSE BLK ABOVESET BOTT. @ 7-5"TOP BRG @ 9'-5"23'-1034" 12'-8" FLAT CLG. 9'-4" FLAT CLG.208F16-1B-1T<1000<50013'-8"607107531412'-0"2016"W. x 24"H.NICHE24"W. x 16" NICHEIN KNEEWALLRAIN & SHWRHEADSCOL. TO CLG.(2) 2x4 w/ 12" SPACERNOTE:PER OWNER REQUEST,HOLD LEADING EDGEOF COUNTERTOP A MIN.OF 8" INSIDE LIVING ROOMREAR FINISH WALLNOTE:PER OWNER REQUEST,DO NOT INSTALL SHELVINGIN CLOSETS, LINENS, & PANTRY.SHELVING AND ACCESSORIESTO BE LEFT INSIDE GARAGE4" CONCRETELANDINGON GRADE4'-0"4'-0"200 A PANELLOCATE IN FIELDMETER, HOUSING& MAIN 200 ADISCONECTLOCATE IN FIELDSH 25 EGRESS 5SH 25 EGRESS 53080 SC 63'-7"WC9'-4'' FLAT CLGWALK-INCLOSET22'' x 22"ATTIC ACCESSFIELD LOCATEA/Hon standR/A(2) 3080 LEAFSw/ SINGLE LITECLEAR GLASSD.SYMBOLREPRESENTSWALL TYPE LEGENDCMU WALL - 8" (U.N.O.) BRG. HT. @ 9'-5"INTERIOR SIDE - SMOOTH FINISH PAINTEDEXTERIOR SIDE - STUCCOCMU WALL - 8" (U.N.O.) BRG. HT. @ 9'-5"INTERIOR SIDE - 1/2" GYP. BRD. OVER 1x P.T. FURRINGEXTERIOR SIDE - STUCCO FINISH WITH NON GROUTED CELLS FILLED w/ R-9 MINEXPANDED POLYSTYRENE FOAM INSULATIONBEARING PARTITION - GARAGE WALL - 4" (U.N.O.)1/2" GYP. BRD. EACH SIDE OF 2x4 WD. STUDS @ 16" O.C.w/ CONT. 2x4 SILL AND DBL. 2x4 TOP PLATESw/ R-11 BATT INSULATIONBRG.PARTITION WALL - INTERIOR - 4" (U.N.O.)1/2" GYP. BD. ON EACH SIDE OF 2x4 WD. STUDS @ 16" O.C.w/ CONT. 2x4 SILL AND DBL. 2x4 TOP PLATESNON-BEARING - INTERIOR PARTITION - 4" (U.N.O.)1/2" GYP. BRD. EACH SIDE OF 2x4 WD. STUDS @ 24" O.C.w/ CONT. 2x4 SILL AND TOP PLATESNON-BEARING - INTERIOR PARTITION - 6"1/2" GYP. BRD. EACH SIDE OF 2x6 WD. STUDS @ 24" O.C.w/ CONT. 2x6 SILL TOP PLATES2x6 WALL2x4 @ 16" O.C. w/ 58" PLYWOOD SHEATHING, BOTH SIDESINTERIOR SIDE - STUCCO FINISH ON PAPER BACKED LATHEXTERIOR SIDE - STUCCO FINISH ON PAPER BACKED LATHABOVE ROOF LINE / CRICKETCMU WALLS, PIERS, AND COLUMNS @ ENTRY:GROUT FILLED PCL AND CMU WALLS INTEGRALw/ FILLED CELL CMU PIERS AND COLUMNS.TOP OF PIERS AND WALLS @ 12'-9"ALL EXPOSED SURFACES - STUCCO FINISHTHREE 2x4 STUDS NAILED TOGETHER WITH 16d NAILS EACH FACEAT 12" STARTING 6" FROM ENDS. ATTACH POST TO GIRDER/TRUSSW/ (1) SIMPSON "HTT5" AT TOP, & (2) SIMPSON "HTT4" @ BOTTOM, PERMANUFACTURER'S RECOMMENDATIONS FOR NAILS AND BOLTS. NOTE: PAD TRUSS AS REQUIRED @ TOP TO ALLOW FOR TRUSS CONNECTOR NOTE: FOR 2x6 WALL(S), USE 2x6 STUDSP-2 POSTP-1 POSTTWO 2x4 STUDS NAILED TOGETHER WITH 10d NAILS EACH FACE AT 12" O.C.STARTING 6" FROM ENDS. ATTACH POST TO GIRDER/TRUSSW/ (2) SIMPSON "MTS20" AT TOP, & (1) SIMPSON "HTT4" @ BOTTOM, PERMANUFACTURER'S RECOMMENDATIONS FOR NAILS AND BOLTS. NOTE: FOR 2x6 WALL(S), USE 2x6 STUDSTHREE 2x4 STUDS NAILED TOGETHER WITH 16d NAILS EACH FACE AT 12" O.C.STARTING 6" FROM ENDS. ATTACH POST TO GIRDER/TRUSSW/ (2) SIMPSON "HTS20" AT TOP, & (1) SIMPSON "HTT4" @ BOTTOM, PERMANUFACTURER'S RECOMMENDATIONS FOR NAILS AND BOLTS. NOTE: FOR 2x6 WALL(S), USE 2x6 STUDSDUAL CONTROL10'-0" FIN. TO FIN.CRASHPOLE20'-61 2" GIDER TRUSS 16" x 72" DSSH 35 OBSC2'-314"4'-6"3060 GLASS9B.P. OBSCGLASS DOORSNOTES:-USE MOISTURE RESISTANT GYPSUM WALL BOARD IN ALL WET AREAS-INSTALL 12" HIGH STRENGTH CONTROLLED DENSITY GYPSUM WALL BOARD AT ALL CEILINGS.28x14 DSCLEAR GLAZING18x14 DSC L EA R G LA Z ING18x14 DSCLEAR GLAZING1LINE TO BURIED PROPANE TANKBY SPECIALTY CONTRACTOR16'-8" K1 GIDER TRUSS AND POSTS TRUSS / ATTIC SPACE INSULATION:EXPANDED POLYURETHANE ICYNENE FOAMINSULATION - R-30 AVERAGE (R-3.7 PER INCH x 8")SPRAY APPLIED TO UNDERSIDE OF ROOFSHEATHING AND ENCAPSULATING TOPCHORDS AND FRAMINGCOVERAGE:OVER ENTIRE CONDITIONED SPACES AND GARAGE.PROVIDE VERTICAL THERMAL BARRIERSAT LANAI AND ENTRY USING R 30 BATT INSULATION.OPTION:R-30 BATT INSULATION INSTALLED ABOVEGYPSUM BOARD CEILINGS OVER CONDITIONEDSPACES AND GARAGE WITH VERTICAL THERMALBARRIERS AT LANAI AND ENTRY USINGR 30 BATT INSULATION.CHRISTOPHER D. BEERS, P.E.FLORIDA LICENSE NO. 64594W A T E R - A I R - L A N D5109 Grand Palmetto WayNorth Port, Florida 34291-8049941-628-0635fax 413-687-9013chrisbeers@byu.netFUTURESINK8ST. LUCIE COUNTY, FL. 349?? (UNASSIGNED) BROCKSMITH RD. CARLOS L. & JENNIFER L. WELLS HARBORVIEW CJW 511 SW PORT SAINT LUCIE BLVD. PORT ST. LUCIE, FL 34953P4 09 DEC 20P1 11 SEP 20P2 25 SEP 20P3 23 OCT 201/4" = 1'-0"A2FLOOR PLAN3SHEETDESCRIPTIONDATEREVBuilder:Project:SCALE:OFMODELOWNERDESIGN BYCHECKED BY12345678HARBOURVIEW CJW PERMITSET(2021-02-23).dwg09/11/20CONNECT BEAM AT EA. END TO WALLW/(1) HHETA16 & (1)MSTCM40BEAM SEAT-CONNECTCONNECT BEAM AT EA. END TO WALLW/(1) HHETA16 & (1)MSTCM40BEAM SEAT-CONNECT