HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: St. Lucie County Walton Community Center Remodeling
Project Address: 11090 Ridge Avenue, Fort Pierce, FL
Permit #: Occupancy Type: A-3 Construction Type: Type V
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Existing Building Code Sixth Edition with 2017 Supplements using ASCE 7-10
2. Structure Designed as (check one):
X Enclosed Partially Enclosed
Open
3. Risk Category: I X II
III IV Exposure Category: B
C X D
4. Design Wind Velocity 170
mph ASD X LRFD End Zone Width:
3 ft
5. Mean Roof Height 181-6"
ft Roof Pitch: 5 :12 Parapet:
N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label
on all plan openings):
Zone 1: +27.4, -43.5 Zone 2: +27.4, -75.8
Zone 3: +27.4. -112.1 Zone 4: +47.6. -51.6 Zone 5: +47.6, -63.7 Garage: N/A
7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF
Dock: PSF Deck: 80 PSF Stairs: 100 PSF Fence: PSF Railings: 50 LF PSF
8. Were Shear Walls Considered For Structure? Yes X Not Applicable Explain Why Not:
Existing historic structure; no structural work involved.
9. Is A Continuous Load Path Provided? Yes X Not Applicable Explain Why Not:
Existing historic structure; no structural work Involved.
10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Don Bergman, AIA
Print Name Cert # & Co. Cert Auth.
;A AR0013560
Don Bergman Architecture LLC, 4362 Gator Trace Ln., Ft. Pierce, FL 34982
Company Name & Address
Revised 12/07/2018