Loading...
HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: St. Lucie County Walton Community Center Remodeling Project Address: 11090 Ridge Avenue, Fort Pierce, FL Permit #: Occupancy Type: A-3 Construction Type: Type V INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Existing Building Code Sixth Edition with 2017 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: I X II III IV Exposure Category: B C X D 4. Design Wind Velocity 170 mph ASD X LRFD End Zone Width: 3 ft 5. Mean Roof Height 181-6" ft Roof Pitch: 5 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +27.4, -43.5 Zone 2: +27.4, -75.8 Zone 3: +27.4. -112.1 Zone 4: +47.6. -51.6 Zone 5: +47.6, -63.7 Garage: N/A 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: PSF Deck: 80 PSF Stairs: 100 PSF Fence: PSF Railings: 50 LF PSF 8. Were Shear Walls Considered For Structure? Yes X Not Applicable Explain Why Not: Existing historic structure; no structural work involved. 9. Is A Continuous Load Path Provided? Yes X Not Applicable Explain Why Not: Existing historic structure; no structural work Involved. 10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Don Bergman, AIA Print Name Cert # & Co. Cert Auth. ;A AR0013560 Don Bergman Architecture LLC, 4362 Gator Trace Ln., Ft. Pierce, FL 34982 Company Name & Address Revised 12/07/2018