HomeMy WebLinkAbout5309 palm dr fa health departmentAPPLICATION #:AP1449778 STATE OF FLORIDA PERMIT #:56-SF-2010882 DEPARTMENT OF HEALTH DOCUMENT #:F11581901 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:10/23/2019 FEE PAID:545.00 RECEIPT #:56-PID-4206515 APPLICANT: Adams Homes of Northwest Florida, Inc AGENT: Benjamin Drew"s Plumbing & Drain Services PROPERTY ADDRESS: 5309 Palm Dr Fort Pierce, FL 34982 LOT: 44 BLOCK: 49 SUBDIVISION: Indian River Estates ID#: 3402-608-0346-000-6 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [11 1090.00 [21 [ ] (271 SURFACE WATER FT [ ] [021 TANK MATERIAL Polypropylene [ ] [281 DITCHES 15 FT [ ] [031 OUTLET DEVICE [ ] [291 PRIVATE WELLS 100 FT [ ] [041 MULTI -CHAMBERED [ Y N ] [ ] [301 PUBLIC WELLS FT [ ] [051 OUTLET FILTER Polylok PL-68 [ ] [311 IRRIGATION WELLS FT [ ] [061 LEGEND 1. 70-143-11 DC4 2. [ ] [321 POTABLE WATER 24 FT [ ] [071 WATERTIGHT [ ] [331 BUILDING FOUNDATIONS 5 FT [ ] [081 LEVEL [ ] [341 PROPERTY LINES 18 FT [ ] [09] DEPTH TO LID [ ] [351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 681 [21 SQFT [ ] [36] DRAINFIELD COVER [ ] [111 DISTRIBUTION BOX HEADER X [ ] [37] SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1. 9.00 2. [ ] [381 SLOPES [ ] [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 02/17/2021 [ ] [141 DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM 5.00 [ ] [401 UNOBSTRUCTED AREA [ ] (171 SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF [ ] [181 DOSING PUMPS [ ] [421 ALARMS [ ] [19] AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT [ ] [201 AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA ( ] [211 AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN [ ] [461 FINAL SITE GRADING FILL / EXCAVATION MATERIAL [ ] [471 CONTRACTOR Bruce T Mc Cullers (Reliable T [ ] [221 FILL AMOUNT [ ] [481 OTHER ADS MPS-9 (9 pipes - 2 tier) [ ] [231 FILL TEXTURE [ ] (24] EXCAVATION DEPTH ABANDONMENT [ ] [251 AREA REPLACED [ ] [49] TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] [501 TANK CRUSHED & FILLED Comments: Comments are on page 2. / St. Lucie CHD DATE: 11/04/2020 CONSTRUCTION [ APPROVED DISAPPROVED Enviro ntal Specialist III (ENVIRONMENTAL HEALTH) J Ingram (ENVIRO FINAL SYSTEM [ APPROVED / DISAPPROVED ]: St. Lucie CHD DATE: 02/17/2021 'Brian Environmental SpecialisP J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Datahase v 1.0.1 AP1449778 EID2010882 STATE OF FLORIDA J r. 2j DEPARTMENT OF HEALTH c' ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION #:AP1449778 PERMIT #:56-SF-2010882 DOCUMENT #:F11581901 DATE PAID:10/23/2019 FEE PAID : 545.00 RECEIPT #:56-PID-4206515 The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 400 gpd. New ST, filter, and 5x23'+3x30'+lx22' long BED DF installed. No violations, system ok to cover. Contractor notified onsite. Needs final inspection for mound system and final site grading. Final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1449778 EID20'10882