Loading...
HomeMy WebLinkAboutHealth DeptSTATE OF FLORIDA 1 DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM �y CONSTRUCTION INSPECTION AND FINAL APPROVAL .,soo w,s.r4 APPLICANT: Duverton and Veronica Daniels AGENT: Jim MautZ PROPERTY ADDRESS LOT: 4 2990 Johnston Rd Fort Pierce. FL 34951 BLOCK: APPLICATION #:AP1422523 PERMIT #:56-SF-1972780 DOCUMENT # : FI 1578665 DATE PAID:07/08/2019 FEE PAID:660.00 RECEIPT #:56-PID-4009250 SUBDIVISION: ID#: 1327-806-0004-000-9 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION [ ] [01] TANK SIZE [1] 1200.00 [21 [ ) [021 TANK MATERIAL Concrete [ ] [03] OUTLET DEVICE [ ] [04] MULTI -CHAMBERED [LZJ N ] [ ] [05] OUTLET FILTER Polylok PL-122 [ ] [06] LEGEND 1. 01-011-12DC3 2. [ ] [071 WATERTIGHT [ ] [081 LEVEL [ ] [09] DEPTH TO LID DRAINFIELD INSTALLATION [ ] [10] AREA [1] 600 [21 SQFT [ ] [111 DISTRIBUTION BOX HEADER X [ ] [121 NUMBER OF DRAINLINES 1. 5.00 2. [ ] [131 DRAINLINE SEPARATION [ ] [141 DRAINLINE SLOPE [ ] [15] DEPTH OF COVER [ ] [161 ELEVATION [ ABOVE / BELOW ]BM 19.00 [ ] [171 SYSTEM LOCATION ( ] [18] DOSING PUMPS [ ] [191 AGGREGATE SIZE [ ] [201 AGGREGATE EXCESSIVE FINES [ ] (211 AGGREGATE DEPTH FILL / EXCAVATION MATERIAL [ ] [221 FILL AMOUNT [ ] [231 FILL TEXTURE [ ] [241 EXCAVATION DEPTH [ ] [25] AREA REPLACED [ ] [26] REPLACEMENT MATERIAL Comments: Comments are on page 2. SETBACKS [ ] [27] SURFACE WATER FT [ ] [28] DITCHES FT [ ] (291 PRIVATE WELLS 100 FT [ ] [301 PUBLIC WELLS FT [ ] [311 IRRIGATION WELLS FT [ ] [321 POTABLE WATER 100 FT [ ] [331 BUILDING FOUNDATIONS 7 FT [ ] [341 PROPERTY LINES 83 FT [ ] [351 OTHER FT FILLED / MOUND SYSTEM [ ] [36] DRAINFIELD COVER [ ] [37] SHOULDERS [ ] (381 SLOPES [ ] [391 STABILIZATION 02/04/2021 ADDITIONAL INFORMATION [ ] [40] UNOBSTRUCTED AREA [ ] [41] STORMWATER RUNOFF [ ] (42] ALARMS [ ] [43] MAINTENANCE AGREEMENT [ ] [441 BUILDING AREA [ ] [451 LOCATION CONFORMS WITH SITE PLAN [ ] [461 FINAL SITE GRADING [ ] [471 CONTRACTOR Chris Flaherty (Accurate Sep [ ] (48] OTHER INFILTRATOR Quick4 EQ36 (single c ABANDONMENT [ ] [ 4 91 TANK PUMPED [ ] [501 TANK CRUSHED & FILLED CONSTRUCTION [ St. Lucie CHD DISAPPROVED ] ' Envir ental Specialist II J Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ] : try____. St. Lucie CHD Environmental Specialist Brian J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC EH Database v 1.0.1 AP1422523 EID1972780 DATE: 11 /03/2020 DATE: 02/04/2021 Page 2 of 3 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION # : AP 1422 23 PERMIT #:56-SF-1972780 DOCUMENT # : FI 1578665 DATE 2AID:07/08/2019 FEE PAID:660.00 RECEIPT #:56-PID-4009250 The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 460 gpd. New ST, filter, and 5x10 long TRENCH DF installed. No violations, system ok to cover. Contractor notified onsite. Needs final inspection for mound system, gutters, and final site grading. Final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1422523 EID1972780