Loading...
HomeMy WebLinkAboutTrussFIFER TO PACK FOR COMIECDOHL 0 t r-w TYPICAL 7P SETBA CORNERSET LABEL AND SPACING SHINGLE RO 6 Ilp- ,Zy,4 HEED-3/1 _ PLUMB CU f- p Reviewed for Cote C�jj Compliance Universal EngineeOgq Sciences NOTE, MULTI -PLY GIRDER CO?4 ECTm ALL PLIES SHALL DE FASTFND TOGETHER UMTS, NAILS, AND I SCREWS) PRIR TO INSTALATDIN MID BEFIM ANY LIDS ARE APPLIED. PER THE SUPPLIED ENGDEERING SHEETS NMI m HIT CUT IR ALTER TRUSSES HITIWT CONSENT IF THIS OFFICE BACK CHARGES WILL MT BE ACCEPTED WITHoOT PRD]R WRITTEN APPROVAL BY OUR SERVICE DEPARTMENT AT CARPENTER CONTRACTORS DF AIERICA, DC On-293-9487 NOTE. ALL BEARING WALLS MUST BE ADEMATFLY DESIGNED TO CARRY THE LOADS DPOSED BY THE TRUSS OR TRUSSES, MID MUST BE IPLMS AND IN SERVI BUM THE TRUSSES ARE SET IN ORDER M AV® REPAIRS. Labeled End Mark Total Truss Quantity = 69. THIS IS A TRUSS PLACEMENT PLAN. ITS INTENDED TO AID IN THE INSTALLATION OF TRUSSES. ENGINEERED TRUSS DRAWINGS AND ARCHITECTURALS SUPERCEDE THIS DOCUMENT. General Notes 1) N PWON dvd tamr, Hat tAd.m aW Hd Wd= h= the tap dWd Ply px*W VW to be kwWW 1 ede aR 2) N �e toM Snpam Ht1528 m m otb� ndm 3) N the Rmk9 is 24 O.C. taima otlri�e noted 4) Pw Tim Plot. naMb DM -M ncvaa.wasm pammat x-bm*V *mM be OXW at a m. po ig T5 Of- a be apao, to be mpadtad at a ntmamtn d 2B bdrat mah x-0taae H.agiat H" sbttabm PHeor mla• m BC9-A" for any adddional bmft MAIL ROOF LOADING SCHEDU TCLL = 20 PSF TCDL = 7 PSF BCLL = • PSF BCDL = 10 PSF TOTAL = 37 PSF DURATION = 1.25 % NAND SPD/TYPE=160 ENCLOSED BLDG EXPOSURE = C USAGE = RESIDENTIAL CAT R NAND IMPORTANCE FACTOR= 1 UPUFTS BASED ON-- 9.2 PSF DESIGN CRITERIA FRC 2017 TPI 2014 T—member de & & wnnector plates am designgnedt rASOL7-10 and-'116 m f fmmboth components ®d claddmgs and main wind fore rosistmg systems. ad!• These I .. have been reviewed to m y - t ona1 109 psfnonJ d. bosom chord hi load FLOOR LOADING SCHEDU TCLL = PSF TCDL = PSF BCDL = PSF TOTAL = PSF ROOF DESIGNED FOR SHINGLE ALL RnCnONs AND UPLIFTS ARE SHOWN ON ENGINEERING WALL KEY O6P_8� ® 0 DESCRIPTION MR. DATE tint az tav a tMr � CA f1ELNIIDAaell IW � oUVO V11LLR lfIIfQ Q o M1P 1!V VM !? C salts � aa1'!L W 1LV VM tata a to s � vrttowto•n:rre ars ■� MlaO It.V NRY llri>1� s � s � I (—� CARPENTER CONTRACTORS OF AMERICA 3900 AVENUE M N. W. WINTER HAVEN FLORIDA 338M PIflNEP C800) 959-8806 FAX- Ce63) 294-2488 BUILDER D.R. RORTON STATEWIDE PROJECT CREEESODE MODEL 1672/ARW4RAB CCA PROJ/MODEL/ALT 7A5/ 320/167ED ALT DESC OTC 3322 TRINITY CDNCLE LOT 42 BLOCK DESIGNER RFS PAGE DATE 3 29 17 �N63986R SC 1 A4 "=1 P REFER TO Eh I PACK FOR CONNECTION. TYPICAL 7' SETBA CORNERSET LABE1 AND SPACING sv�s �v rjoA Axi-te I,Vk � li yam n p t7 O NQTD NILTI-PLY GIRDER CTBNECTICK ALL PLIES SHALL BE FASTEND TDG ER (BOLTS, NAILS, AND OR SCREWS) PRIOR TO INSTALATI N AND BEFORE ANY LOADS ARE APPLIED. PER THE SUPPLIED ENGINEERING SHEETS Nm DO NOT CUT OR ALTER TRUSSES WITIOJT CMSENT [F THIS DEICE BACK CHARGES VD.L NOT BE ACCEPTED WITHOUT PRIOR VRETTEN APPROVAL BY OUR SERVICE DEPARTMENT AT CARPENTER CINTRACT13RS [F AIERICA, M 877-293-9497 NOTE,. ALL BEARING WALLS MUST BE ADEQUATELY DESIGNED TO CARRY THE LOADS IMPOSED BY THE TRUSS OR TRUSSES, AND RUST BE ItPt.ACE AND IN SERVICE BEFORE THE TRUSSES ARE SET IN OD]ER TO AV® REPAIRS Labeled End Mari( Total Truss Quantity = 73 THIS IS A TRUSS PLACEMENT PLAN. ITS INTENDED TO AID IN THE INSTALLATION OF TRUSSES. ENGINEERED TRUSS DRAWINGS AND ARCHITECTURALS SUPERCEDE THIS DOCUMENT. General Notes 1) AIp-W and t..k flat to® and "A *dwa hmw Um toP and P.V* Pdbd San to bs hddsd Owr, ids w D) N fnq� to bra Sirpon HLMB air otl,r6 dsd. 3)'. Al bm q iq h 14' O.C.air aU..1 n9tod. 4) Par Tram Hato I mft BC9-81 rasnm daft Pw^snnt X-broarp OvA be pl—d at a madman WDdkl 15' O.C. o=aa the rpm, to bs rq@OA at a madaan of 20' b tw sad %iron BsarfroN Ur s6ndrs. . afr fa BC9-Of for any additional b odn ROOF LOADING SCHEDUL TCU. = 20 pPTCDLPSF BCDL 10 PSF TOTAL = 37 PSF DURATION 1.25 6 WIND SPD/TYPE 180 ENCLOSED BLDG EXPOSURE = C USAGE=RESIDENTIAL CAT H WIND IMPORTANCE FACTOR= 1 UPLIFTS BASED OW 9.2 PSF :DESIGN CRrr R FBC 2017 TPI 20L4 Truss member des�'�ggn,ad: caanecmrphtes arc dcsi��aaed for ASCG7-10 and mi<imam farces Aom boimponeoss and claddings and mmn winn d force rtsrsnng syslcrns. • Thrsc auz;as hasx bccn rndcwcd to curry an addilioaal 100 psfnon<a rcatboaom<bNByre load. FLOOR LOADING SCHEDUL TCLL PSF TCDL = PSF BCDL - PSF TOTAL = PSF ROOF DESIGNED FOR SHINGLE ALL REACTIONS AND UPLOPM ARE SHORN ON ENGINEERING WMI KEY w un m"a nw morn lot — s na Q aramr as s � nNL VNiaT ila® - Q aYa/N � oar ry ove a,.w nnarsa NUM ra'r .viMl ran RV VnE a < m wn aan. r Sao m .ax ansirr rm ur Q arnarn ARM on or nsa wrrrsc r aaszr rau rraoaa arcv, sssnns saaQ wn� [DAD/ DESCPoPfm INIT. DATE wn sa rs+f - aura r icv, sane .wa wns CARPENTER CONTRACTORS OF AMERICA 39M AVENUE G. K W. WINTER HAVEN FLORIDA 338BO PHONE (600) 959-8006 FA* (863) 294=2488 BUILDER D.R. HORTON 3CATERIDE PROJECTCREEKSIDE MODEL 1197E/ARIA/4EAB CCA PROJ/MODEL/ALT 7A6/ 167EC/ ALT DESC OTC 3234 TRIN11'Y CIRCLE LOT 42 BLOCK DESIGNER PAGE TR�FS DA 3/29 17SCA 1 �NA333978R 1/4 "=1'. Builder: Project: Model/Building: Lot Alt: ENGINEERING PACKAGE DR_HORTON / STATE_WIDE 7A5C3� =167ED Lot: 42 Block: Address: 3322 TRINITY CIRCLE ......................................................... _ ............................ JobNumber:N333986 ................................................................................................................................... Unit:__ ..�.. Revision Date: New Load #: 'RG01 Re►ria„,ed for Cow Ugn e E annce�,d regc� CARPENTER CONTRACTORS OF AMERICA, INC 3900 AVENUE G. N.W. WINTER HAVEN, FLORIDA 33880 PH (800) 959-8806 FAX (941) 294-7934 ALFIN . E March 13,1019 -AN rTW COMPANY Me. bol:�. Michaelis Carom t6r.* Cbritractor's of Am6fida,. Inc., 39.00 Avenue., G, N.orthWpst Writer Hav6n,;:F L 33.880-6201 Re: Alternative install6tioris.,for a singe pl'y-' carried truss with a width Jess than the hanger width, :and: wood blocking lo:achieve full design load value for face-..mounted:ha ger:attachment -'ri non'4:one ply sup, 06fting girder (Reference detail .W.MT-02)... Dear Bob, For single ply carried truss with "a width less than the hahget. widthyoucan install -a prefabricated jack. scab . truss �) for wooc.(.'flller blockirigi The c I hord . sizes,, c. hord grades, and -Alpine: :c6hn*ctbrplates) . plat6( s) to be the. same as the single: ply carfie.d. truss. The prefabtidatdd jd&*sdabtruss (*);will have a.minimum Iength of 48"and will ' * have a. minimum pitch.;of 5112.. The single. ply;parried leuss shall have:.a reaction of 1,500# or less, QW.5 0.i : 28'x3..07*GUn Nails at.2' 0..'Q per r6W,. staggered V (See .'Figure I beld Pl6a'sd.fef6rtoth' eSirhpsqn 8trong:­Tie Catalog G-C' 201.9i page 216 Figure, for more information,. Alg6re-I Fpr:a single ply " * * * * 'required wood to,achie'v&%fUll.desigh load value: for face -mounted . 1 " itderAW tequi W6 n _hangers attach one wood block tl to the back face of tgirder single gird with thesame size: and gjraje_as the bottom: ch6ff*0f the .single ply girder. The-Voci.d block length to be such ftat.the'w"6od blocking extends to each adjacent panel lointp:(Webs and b6ft6rn chord intersections):.. _Attach wood block OunNails per row, staggered 3. 0":applied to the 676.0: Forum Drive Suite 805i. Orlando, FL 32821 - (80o) 6 1-910.0 -.(1363) .22-,.8686 www.alpineihwoom Iq ALPINE NAWCO� . single ply girder.face, with an additional (20) 0128"x3 0" Gun.Nails at each panel point applied to the; wood. block:face (See Fi'0,0*2 below). Please refer to the Simpson Strong Tie:Catalog C�C`20'19, page 21.6 Figure.l for more' information. Figure 2� The application of prefabricated jack scab truss for,wood iller'.tilocking_of wood:blocking to: achieve full design load value for face=mounted hangers must be approved by fhe hardware.manufactiarer All edge. and end: distances, and spacing fof all nail connectior s must be sufficient:to prevent splitting of wood.: If I can.be. of any further assisiance:or if you have any questions, please-giye me a :call. .No�706fi1• STATE C! William H:. KngK;N.t. Chief Engineer Alpine an ITw Company Engineering Department' Orlando;-Fl- 6750 Forum Drive. Suite 305; °Olando, F4.32821 - (800):521-9.790.- (663) 422-8695 WWW.2iPine6. q.-00rh TM ALPINE M"Cowlmw April 26:,.2019- Mr. Bob Michaelis Carpenter rperter Contractors of America, Inc. 3900 Avenue J�, Northwest Winter Hbv6n, FL 33880-6201: Dear Bob, Re' Str6ndbai*ok bridgidg6i) tbdf:trU§se,§. I -understand there. is some concern over our recommendations fdrstrongb6c'k. bridging on f6oftrus'ses.. Sfrongback bridging for roof trusses is not requirement of ANSVTPI 2014, nor is i a reqdir mentofthe. Building Component Safety Inform on- "(SCSI),-.13, ut strorigback bridging;* on roof trusses is recommended. by -Carperiter. Contractors of." America: Ztr6hgbalck bridging *.s6rV6§ the. following two. functions:, One, bridging aliops the bottom -chords -pftpr they are set so the are uniform along the hq ceiling line and helps. with c0ilin4serviceability Twoj bridging relative defiectiofi:& adjacent: ttuss6s., .Ogi...g reducep . Strongback. bridging". 'do e*s.hot--pr&Vbnt or reduce. overall indiViddM deflection, especially any roof trusses _,deflect ore than 10. inch - ..... . ....... .. . .............. .... . ..... ,$trpng0ack- bridging in roof. trusses does not terv'eil-as terhp6ra-r-y*..br*pdrm*an'66t.braci'ng ' and is not intended to distribute. . bute. or share design loads:' between trusses. Consequently, no design. esibrt . I I oad' have -been accounted forWith this detail and dbntihUbLis..strohobdck'bridgihd'should not be attached between: common and girder 'trusses.. The. use stroNback, bridging. not .interfere with other- d6si n considerations as specified .�y the Engineer. of Record drthe Build ­ ing De$i . gn6r. Th6 outer ends of IMstron4back bridging shall be, attachedao a wall or another secure end. restraint, or as specified'by.th6 Ehdihe6r of RedoMbi-thd Building.Deisigh6r, 'Strongback bridging; shall: be -aminimum of 2x6 hortiinal lurnibeir oriented with the depthverti ical. Attach with 16djcqmmion nails (0.1'62"x& s . .5") nails at. each intersecting 'rh6mbet.. When 'extending the I Um oflocation' tio b sttongbatk bridging overlap: by at a trusses. The � of s strongback. n.dging 9 rrijnii� maybe Please refer fio vb6.sp.eciFied'*'b'y:the.'Tru''si� Manufacturer., Engineer of Redord, of Building Designer: BCSI "Strongbocidog Provisions" or to Alpine: S­TR' 14 detail for more inf6r.rription, The. graphic P111,13.R.10.1. sho (Figure_ 1) is for:generic lllu&dtive pUrpose only, 6750 Forum Drive:806 805, Orlando, FL.322821- (800) 521-9790'- (863) 422-8685 ALPINE R V V.! U: L- t.. -A.,L I- k.1y . I :. 0 1: C., 1), S c:d I e.) � Figurej. lfi.:cai'n.bb6fbihyfurthi§r-sissistariwor-Nypuhave!.ari-vaueitions please:-qiVe. Me a: call, William, H. Kndk. O.'P. Ch,ief'E.ngi.heer Alpine an ItW-0o.mpany E Department Qgineenng .614n4ai IFL. $982,11. 6750 Forum Drive SuR6.3.05, Orfin'do; Fl. 32821 - (800).521-9790 - (863) 422-8685 i",. M.alpirie- ltvv.QQM f. 2 --------------- ,'��T N J� S-TRONGSACKI BRIDGING RECOMMENDATIONS --All scabnon blocks shaii, be;.a m! Imu ' n M.��4 BUTT.STRNGBACK :BRIDGING O TOGETHER stress qe ilq!nber,,0 '01 bo-AII. strongback bridging :and bracing shid *be::a oss gradgC1, tu bL-;r mInIhum �X'6 'str.. pi, . . . . ., p�-The purpose of strondba.ck-:bridging . . . . . ATTACH SCAB WITH1-'1Dd:BOXeWN 'MIMXU'�. rievelop"(6ad sharing b&tweert.'Indiv e ru �4 "0' P�6- NAILVIN14 ROWSI�Af :.SCAB :.64 'D.C. res,UttIng In an -o%4ralCIhcr.Rase In, the , , , NDTEi LIEU *OF- SPLICING. AS SHOWN, LAP: ,-STRDNGBACK BRIDGING MEMBERS FOR: AT LEAST 13ME rRLISS.,SPACING St10*ness� o .: f,� the: floor. system -2x6 strongbatk brid Ing(,. 0 ;positioned dsa.shii Wih In STRONGBACK :SPLICE DETAIL details, Is recommended 10' NOTE, Detalts ,I and .2..,arle 'the :preferrOldatt*achmeht memthods, *.-The terms- 'bridging' and, 9 -1)#,acin ,are. sometimes . 'ed ATTACH STRDNGBACK 70 WEB W/ :(3) 10d. COMMON y: used- mistakenly - Interchangeably 'Bracing' �(0.148'XV)- NAILS.'OR Hportant.' structural riequ rement o an f toor M.40d MX/GUN 28?x3,0*),. NAILS O. or roof system. ke�e?_' to the Truss. Di"Igh -Drawing MP For 'the: bftkcIng r.e,'uI?,'&mghts :f br each' Individual truss component. Bridging o i particularly- Istrongbadk--"bHclgln!j..I'Z,:.LX.- i recornmenda ilon for 'a truss system to help control Vibratiot).. In: addition to.:dIdIng,.-'in the. distribution of point' Ibads between adjacent "br4dbing• 1 - truss, •st-rongback, serves' to reduce .OR , I AT 9TRO AN TrWCOMPAW j1h;-d-4 13723 RWn3bd D& sung 200.I'M M-F&4 HeIghtsimo GM3: i ,RONGBACK BRIDGING. QG'REQUIREMENTS I I to IV None' riqub-ed 1 tow2v I ragld wrkr ff gW. nch In pc�ts) to* 40 140 gnuwm boun -ce or residual. from Moving 4point l'Oqds,-sUch as footsteps, The Performance: 6f..cx.LL `floor :systems -are enhanced by. the. Installafth of strotig'ba.ck- 1prIdgino and thereforels:`­strongly recommended - by Alpine, For additional Infqwhatidn rkeijqf-dIhq stro6qbq�.* bridging, refertp' -BCSI (BuIL61ing. Component. Safety- Information), LL. PSF T No. 708.6*1 - .D L�%. , PSF AC aDL PSF I?9F Y D. -PSF l k .1 n1J1R�..•.9h1[''Ji�Xid.�•'�6'�"'R��r��'- :.. ... ..... .. 1. . . 'NO.l'e: 'IF' 4t, F 'OF _ i NS.-TR CTION :'f�X-M- E- G, x bdi 1q 1WRE hf�'fitl� 1 ':Jt 4':l?'(f T 'l1 p 'F- •:: tXCli O'ffl i (0' jiJFI MrtTixAL.- ALL i < SZE 'AP-PAQPRTa. k. P l ':1�T CPC : ('�Fl:.�.0618E.A. PLAM-t AND.: } Q NEt GI, T r aj. 5 N:k ,q . • i' x3tsi'd.iFtE.1�i�erErt ti its. .: Mac. SitdtZ 'h#[, fiK:r. .1AL xt O t.kB�FF: .:. t s:r+�ir� At a To. 'HF �:t Vs. in's MA i �R�A ,` : TQ• '. Fib s�.gY lsi�s ksij,! �'s 5 !'' lei cr Y HE �a, �#�h�'TOR: Al :... his ,����• •I��n�k� � ��' ��,�fi•:��;lsiyc�'. -. .: .. .. .. lb 14 r ��^•CJ1'..+'�.�j�l��":r'•,}T,-].";��'F`�'r^ta'S.1�q�:�;,:1:i.4%4:I.J.'.G.F'1' ram. r 'ems cm, { o en. at T--Li:.,.• .._.__ _ h A._: �' u._.��. �. �..? L.'.: ., k . 4. h.4:.. 4 : ti4. �''..0 i:h:����:S4 :i hti'i`�'��y_._� _i_� I- • ,_: 5.... _ _ _ _ _ �, Cracked or Broken This drawing specifies repairs for a truss with broken chord or web member, This design Is valld only for single ply trusses with 2x4 or 2x6 broken members, IVo more than one break per chord panel and no more than two breaks per truss are allowed. Contact the truss manufacturer for any repairs that do not comply with this detail. (B) = Damaged area, 12' max length of damaged section (L) = Minimum nalling distance on each side of damaged area (B) (S) = Two 2x4 or two 2x6 side members, same size, grade, and species as damaged member, Apply one scab per face. Minimum side member length(s) = (2)(L) + (B) Scab member length (S) must be within the broken panel, Nall Into 2x4 Members using two (V rows at 4' o,c„ rows sta gered. Nall Into 2x6 members using three (3) rows at 4' mc., rows staggered, Nall using 10d box or gun nails (0.12814', min) Into each side member, The maximum permitted lumber grade, for -use with this detail Is limited to Visual grade 01 and MSR grade 1650f. This repair detail may be used for broken connector plate at cold -panel splices. This repair detail may not be used for damaged chord or web sections occurring within the connector plate area. Broken chord may not support any tie -In loads, s• L L 4' o,c �Typlco. + O + O + O + 0 O + O + 0 + O + S2' tagger + = Back Face loci Box (0.128' x 3', min) Nallsl O = Front Face 2x6 Member - Triplee Raww Stagoere Member-; Repair Detall Load Duration = 0% Member forces may be Increased for Duration of Load Maximum Member Axial Force . Member Size L SPF-C HF DF-L SYP Web Only i 2x4 12' 620# 635# 730# B00# Web Only 2x4 18' 975# 1055# 1295# 1415# Web or Chord 2x4 24 9750 1055# 1495# 1745# Web or Chord 2x6 1465# 1565# 2245# 2620# Web or Chord 2x4 30' 1910# 1960# 2315# 2555# Web or Chord 2x6 2230# 2365# 3125# 3575# Web or Chord 2x4 36, 2470# 2530# 2930# 3210# Web or Chord 2x6 3535# 3635# 4295# 47454 Web or Chord 2x4 42 2975# 3045# 3505# 383544 Web or Cord 2x6 43950 4500# 5225# 5725# Web or Chord 2x4 '48r O 3460# 3540# 4070# 4445# Web or Chord 2x6 5165# 5280# 6095# 1 6660# Nall Spacing Detail ray�A,RR��yI��Oles R[AD AND TOLLCV ALL NOTES ON CN THIS DRAVIN01 -WORTANT, FIIRMSH TNIS DRAVW TO ALL CNTTRACTORS INCLIIDINO THE INSTALLERS. Trusses require rrtrene care in Pabrleotlna, holrAMq, shlppho Install and braelno, Refer to an PoDor the latest edition of Josh OuRdha Cc ponent Safety 1lnf/oreotbn, by TH and SDCA Par safri praetkrs prior to performing those funotlone installers shall provkle temporaryy �brash par ]CS1. bnloss noted otherrlae, top chord shall have properly attached struebral sheathirio anr� bottom a .,a shall have a properly attacked rlOW celtm Locations shorn For prrnnnent lateral restnht of we njj''����n shill hay. braFcFbmqD hstalled per SCSI rretfons 33. 17 or 310, as aptlicoh1r. Apply plot" to each Fa, At L�U 19 Refer to �arinasls ISCA i shown tw atohderr p et � posisltlons, Dstafs, whets ranted otMrvlsr, Alpha, o dNbfon of ITV fusdhp Conponrntr Oraq Ina sAaLL et b* respenelble fora devfatton 1 AN iT11ir COMPANY Mls drorha, any faswr io bWid tM truss In cvnlornanee rHi; ANSI/TPT 1, or for F»nd a, shIPPNa. hstallatkul L • aaA1p M trYfNR A rral'm drosYp ar eoyrt- pa Ilstha this drarhy Mdkntrs accrptotice oP prolesabnsl .nyNa�r,.rq�,+,e,.nslbAHy, solely far iM der^ shorn• Trr Wtahslty and use o1 fits drnrha 1339a Lskehonl Oliva Par on, a a Is In rnpdvlpNet e( job's general notes per kAd t T 1 web EaAh City, MO 3045 For noes Ieltmeanian ere 4Nr at. aenaral voter i prand these reb jsitest c4sa ALPIhO ros�aldneltw,eanl TPh rrv.tp4rt.oral SDCN rerebePndustry,oral ICG rrrJecscfr'nra _ L ' Nlninun L 10stnner e L s �D L Hlnlnum B �L� L Distance L REF MEMBER REPAIR DATE 10/01/14 DRWG REPCHRD1014 SPACING 24.0' MAX 11�S l AMTNOIA.MRA-4100-P1ETX� VALLEY FRA 8 BC 0 TW6S- TOL!b,9- UNDER VALLEY -r-RA-miNG VAL�EtY RAFT—ER.C)R RIDGE IpOlsi3,4'-M`ldr,30 psf JTL)'ajmd-26 pOf (.TDJ wx. lo:tjo..cdppd�.:f�r aXoh rowsWiltod from th# willeys brisleepers work(ii§*.W�.i. d 1.1, U i I....rtag I a 116W6oihatodp'te locatlons are oyt6"6A'Q6*n ft.k.ul.r..ament'Note-, Slfidloe-nails 4168tOE14alli to-b-dii, 4,16iltdiii-Nill.1 3 160 t6d-'MU$.A2jth sleeper. jktruss Rjdga:bobrd.,63 t.00f bldck 4 Ifid toe -nails -Ridiii,80.2fir'd totruss`4 IOAOe Aiiijls 44jillri to (TW)- yrimio.: 6tkia4g* T-russ-t6wipphi: , 4'16st:toe trails Trm 4 .16.d.to e 704M 4 16d*toL-nalls. FE ItDMM& MAIL§ 14".e trusis'l6p. Ohdrds.qkid Wier I b -1 - IT. kOt LISdd, # �Ap (I- I rrentN Sf imm ly 1 equ -Maximum height; 3.0-feet yfIrs ''A, p.hifndWezl,.Exp Dj -F,aInw;' A,N0861 . 9& SO 46 5Rif P FA%ilTd FMM'7M IAMM Q-"-CQ TmZMM.,DmAL=—f: 1 O, -At--k-vt.%Hbitcu V?Q.:h'W. W&� WJto &Px,—t;at.ty..pa . :er 1px:Mr,S$w F IC DL 10 ZO 7 DATE10/Q1j14 practiced pior id wforl*.v ..ff4 tira. 'bkVi k!)XTAl'kq .0 o o DR 801015 -%hom .9 W..G VAPNV.l 't I bkV t sec ko��.O* , I l. per Q;;�� -to -ds qi.� b6vi.. b4&xk. WMFX rwa�:tpd 0 .3.ndard pLatv pim"t� BC. LL 0 - — . 5b R*fW 4w, 'b" 'Ve TPU%r n CoffGrhQM* vr%n AtQw I rL .� w tw 'TbT. LD.3 4.� 61 ­.. . - .. . . , . . .- .. -.If . a dy6k;. -f)[Tv & de be mp-pasaie t 15 - of ABOVs At 1,25 15 rva L -60 7 d U C p y0 '0d a E 7 0 J 7 41 N Q- O _U Face -Mount Hangers - I -Joists, Glulam and SCL BB• _._........................._.......-....._............................................._...._._..__.._............................................................ ... _.._...............-...__..........._.._......__.._.....:....................................-----....__...... _....... _-.._.... ---._.............. _... ........ _. 6 These products are available with additional corrosion protection. For more information, see p.15. Codes: See p.12 for Code Reference Key Chart. F1 A Carried Dimensions Fasteners Ilovua6le Loatls Member , (m) fin) Actual ( DF/SP - SPF/HF Joist Model , Mm ! Code Size ' No.; ti Web :Max Species Header .` Species.Heatler Ref. (in.) , . �' o Stiff, Reqd. .W H-= _ B Face Joist Uplift Floor Snew Roof Floor ._ Snow Roof (160) (100j {115) �(125) {100) (115), (125) Min. (14) 0.148 x 3 - 70 1,660 1,805 1,805 1,425 1,555 1,555 IUS2.56/16 - 2% 16 2 Max. (16) 0.148 x 3 - 70 1,805 005 1,805 1,555 1,555 1,555 21/z x 16 MIU2.56/16 • - 29A6 15N 21h - (24) 0.162 x 3% (2) 0.148 x 11/z 230 3,455 3,920 4,045 2,970 3,370 3,480 U314 ✓ 2% 10112 2 - (16) 0.162 x 31h" (6) 0.148 x 11h" 970 1,945 2,205 2,375 1,675 11,895 2,045 HU316 / HUC316 ✓ 29/16 14'/8 21/2 - (20) 0.162 x 31h (8) 0.148 x 11/z 1,515 2,975 3,360 3,610 2,565 2,895 3.110 113C, 1 2hx18 MIU2.56/18 • 294s l7?/6 21/z -': (26) 0162 X 3Yz,. (2) 0.1$8 x 11Iz �230 3,174,5 4 045. 4 045, 3,220 3 480 3,480 LA HU316 (HUC316 �. _ • ✓' .-2 h6 `"14%-, 21h. ,= (20) 0.162 X 31/z'" ' (8) 0:148 x 11h 1513 2;975. 3;360; '3,610; 2,565 2,895, `3,110 21h x 20 MIU2.56/20 1-1 129,K6 197/�6 21h - (28) 0.162 x 31h (2) 0.148 x 11/2 230 4,030 4,060 4,060 3,465 3,495 3,495 21h x 22:MIU2.56/20 . to26 �.. � • ✓ :2%6 19 �s 21/z <= (28) 0.162 x 31h (2) 0.148,x 11/z 230 4,030 4 060 4,060 3,465 3,495.3,495 21 To 291/4 29/is" wide joists use the same hangers as 21h" wide joists and have the same loads 3 117h MIU3.12/11 - 31/a 111h 21/z - (20) 0.162 x 31/z (2) 0.148 x 11/z 230 2,880 3,135 3,135 2,475 2,695 G,VUU 2,695 IBC, FL, x HU212-2 / HUC212-2 i • ✓ 131A 1 10 -A,, 21h Max. (22) 0.162 x 31/z (10) 0.148 x 3 1,795 3,275 3,695 3,970 2,820 3,180 3,425 LA �_:11­ HU3.25L121HUC3;25/12 t.- - s 31/4 s' 1 lq 21h - .mr (24)`O.162x31h „(12)O.j48x3 j 'Jb 3,570 40304,335 3,OZ5 3,470 3,735 HU3.25116 / 1 HUC3.25/16 s 31h 13'3 6 �" 2% M m.(20).0162 x 31/2' . 8 0.148 x 3 - ( ) :7 515 2 9 5 3 360 3 610 2,560 2,890` 3,105 Max. {26}0162.x 3,1/z {12j 0148 x 3 1 �h 3 870 4 3654,695 3,330 3,755 4,040'. _ 3,�6 glulam HUCO21072=SDS `, • 3% "9 `. 3' 1- (12)'/4' x 2;4"SIDS (6)1/4" x'2%" SDS ';2,045 9t31,; ,31�, /1,31a 3,600 3,710: 3,710 FL HGUS3T25;%0 3'/i 8s%` 4 `- (46)-0.162x_31h (16)�OQ62x3Yz:4;095,'9,10Cf 9100;;9,100 7,825 7,825 7,825 IBC, ';:.` • 3'/a "'0%a 4a 6X'/z 6' , , ,, , ,9, FLHGUS325112 LGU3.25 SDS 31/4 8 t0.30 41h: <= . (16)'/a' X 21Jz" SDS, {12)1/1' x`2'/z" SDS 5 555 6 72Q r 310. ",7 1G: 4,840 7 265; 3;26` 31/2 51/4 HHUS46 • - 35h 1 5% 3 (14) 0.162 x 31h (6) 0.162 x 31h 1,320 2,785 3,155 3,405 2,395 2,715 2,930 x HGUS46 - 35h 1 41/16 4 - (20) 0.162 x 31h (8) 0.162 x 31/s 2,155 4,360 4,885 5,230 3,750 4,200 4,500 HUS48, - - 3% . 615A, 2 ' - ., (6)I0.162 x 1h (6) 0:162 x 31/2 ': W 0' 1,595 1,815 1;960 1,365 1,555 1,680"'. 31/z.x �71/4 HHUS48 - • •, : - :35A 71A 3: '- (22) 0.162 x 31h (8) 0.162,x 31/21,'! p -4 216 4 770. �5, 140 3,615 41095! 4,415' HGUS48 '•` - 35h 71�s _4 = : (38)-0162 x 31h --(12) 0.162x 3'h '3 23ti �,4fi0 7460; ,7,480, 6,415 6,415,16;415' IUS3.56/9.5 - ash 91/z 2 - (10) 0.148 x 3 - 70 1.185 1,345 1,455 1,020 1,160 1,250 MIU3.56/9 - 39/16 81M6 21/z - (16) 0.162 x 31/2 (2) 0.148 x 11/z 210 2,305 2,615 2,820 1,980 2,245 2,425 U410 ✓ 3% 83h 2 - (14) 0.162 x 31/z (6) 0.148 x 3 970 2,015 2,285 2,465 1,735 1,965 2,120 HUS410 - 39A6 815/6 2 - (8) 0.162 x 31h (8) 0.162 x 31/2 2,990 2,125 2,420 2,615 1,820 2,070 2,240 31/2 9'/z HHUS410 • • - 35/a 9 3 - (30) 0.162 x 31h (10) 0.162 x 31h 3,5655 5,635 16,380 6,445 4,845 5,486 5,545 x HU410/HUC410 • • • ✓ 39/16 8% 21/z - (36) 0.162 x 31h (12) 0.162 x 31/z 3,235 7,460 7,460 17,460 6,415 6,415 6,415 HUC0410-SDS - 39/16 9 3 - (12)1/4" x 21/2" SDS (6)1/4" x 2'/z" SDS 2,265 4,500 4,500 4,500 3,240 3,240 3,240 HGUS410 - 3% 9'1A6 4 - (46) 0.162 x 31/z (16) 0.162 x 31h 4,095 9,100 9,100 9,100 7,825 7,825 7,825 1BC, LGU3.63-SDS - 3% 8 to 30 4'h - (16)1/ax 21h" SDS (12)''A" x 21h" SIDS 5,555 6,720 6,720 6,720 4,840 4,840 4,840 LA MGU3.63-SDS - 3% 91/4 to 30 4'h - (24)1/0 x 21h" SDS (16)'A" x 21h" SDS 7,260 9,450 9,450 9,450 16,805 6,805 16,805. IUS3.56/11.88 --� • "-' �3s/a; i1?/e, , , 2 ='':=, (12)'0.148'X3 . _ ;;'0 „ 14,20 1,615? 1,745 1,220: 1,390 1,485 31z x 11'A " ivuU iob1 i I (• - i:ns ll:% U414 --, ., , ! w•` • ✓ 3�46 i0`� -' 2' • - (16) Q.162 x 3'/z"� (6) OJ98 X'3 HHUS410 , ' •, `•` - 35W 9 s '3-,,= - (30) 0.162 z 31h, s(10) 0:162 x 31h- HU5412 • +` - 39h6 101h= . _ 2.- - (10):.162 z 3'/z '(10);0.162X 31h HU412 /=HUC412 •- • 39/16 10,%' 21/z _. Min. , (16) 0,;162 x 3'h. (6) 0148 x 3 q Max. (22) 0.162 x 31h °; (10)-0.148 x 3, 391s 11 - ,'(14)'Yn'"°'x 21h" SDS (6)1/4" x 2h"-SDS HGUS412 • -' 3%a " 1077 6 , , .4. - .(56) 0.162 x31h (20) 0.162'x A LGU3:63 SDS - ,. •''�. - - 35/a " 610-36' � 41h - (16) W, x 2W' SD$ (12)-1/<" x 21h" SDS MG113 63-SDS - ; ' - 35h 91/4 to'30' 4Jz = : (24)1/4'" x 21h" $DS {16) /4' x21h" SDS HGU3.63 SDS " •; +,'I -. _ `3%,' 11,td 30 41h: �,- (36)1/V''x,2'h" SDS 1 (2 4) 114 x 211iV $D; 146 See footnotes on p.150. 4,840 Simpson Strong-Tie®,Wood Construction Connectors Adjustable Truss Hangers �`�EREO W 9J d This product is preferable to similar connectors because of (a) easier installation, (b) higher loads, (c) lower installed cost, or a combination of these features. The THA series have extra long straps that can be field -formed to give height adjustability and top -flange hanger convenience. THA hangers can be installed as top -flange or face -mount hangers. THA4x and THA2x-2 models feature a dense nail pattern in the straps, which provides more installation options and allows for easy top -flange installation. Material: See table Finish: Galvanized. Some products available in ZMAX® coating. See Corrosion Information, pp.13-15. Installation: • Use all specified fasteners; see General Notes. The following installation methods may be used: • Top -Flange Installation — The straps must be field formed over the header — see table for minimum top -flange requirements. Install top and face nails according to the table. Top nails shall not be within 1/4" from the edge of the top -flange members. For the THA29, nails used for joist attachment must be driven at an angle so that they penetrate through the corner of the joist and into the header. For all other top -flange installations, straighten the double -shear nailing tabs and install the nails straight into the joist. • Face -Mount (Min.) Installation — Install face nails according to the table, with at least half of the required fasteners in the top half of the header. Not all nail holes in the straps will be filled. Nails must have a minimum'h" edge distance, Straighten the double -shear nailing tabs and install the joist nails straight into the joist. The face -mount (min,) installation option accommodates conditions where the supported member hangs either partially or entirely below the header. • Face -Mount (Max.) Installation — Install face nails according to the table. Not all nail holes in the straps will be filled except for the following models: THA29, THA213, THA218 and THA413. For all other models with more nail holes than required, the straps may be installed straight or wrapped over the header, with the tabulated quantity of face nails installed into the face and top of the header. The lowest four face holes must be filled. Nails used for the joist attachment must be driven at an angle so that they penetrate through the corner of the joist into the header. • Uplift — Lowest face nails must be filled to achieve uplift loads. Options: • THA hangers available with the header flanges turned in for 35/e" (except THA413) and larger, with no load reduction — order THAC hanger. Codes: See p.12 for Code Reference Key Chart 1 -1li for THAC422 tar 122-2 426-2 01"THAC422 Face nails Top nails per table per table THA418 Double 42 — 2 face nails Use full table value (total) Single4x22r�I) ails See nailer tabl " Straighten the double shear nailing tabs and install nails straight into the joist Typical THA Top Flange Installation on a Nailer (except THA29) THA422 Face -Mount (Max.) Installation Straps may be installed straight or wrapped over with tabulated face nails installed into top and face of heads ® Double -Shear Double Nailing Dome DoubleShear Shear 1 Nailing Side View Side View; j Nailing n Available on Do not IV Top View g „"� bend tabsome models) "a/ Straighten the double shear nailing tabs and install nails straight Typical THA422 Top Flange Installation on a 4x2 Floor Truss THA44 Face -Mount (Min.) Installation iyNicai I nnca Top Flange Installation 'er to tnote 5 p.187 186 THA/THAC Adjustable Truss Hangers (cont.) These products are available with additional corrosion protection. For more information, see p.15. u 0 Model No. �a' Dimensions Min. Top Flange (in.) " Min. Header 'Depth Uri) Fasteners (in.) �` Carrying Member "' Carried Top = Face- Member AF/SP = 1111owable Loads Roof / Uplift Floor Snow ; Wind ` (160) (1110J (115) '1251f60 ( ) SPF/HF ' � Allowable -Loads Roof / Uplift Floor; Snow Wind '(160) (100) (115) G125/160) Code Ref. W . H C ,,; T`ap:Flange Ins2agatlon THA29 18 l s/a 91'tis 51% 11/2 — (2) 0.148 x 3 (6) 0.148 x 3 (4) 0.148 x 3 525 1,750 1,750 1750 450 1,330 1:330 1 1,330 27A6 — (4) 0.148 x 3 (6) 0.148 x 3 (4) 0.148 x 3 525 2:610 2,610 2,610 450 1 985 1,985 1,985 THA213" 18 � Isla 13'A6 5/2' 2 — (4) 0.148 x 3 (2)-0.148 x 3' (4)A:148 x 1'/z .. .... _ THA218 18 15/a 173/s 51/z 2 — (4) 0.148 x 3 (2) 0.148 X 3 (4) 0.148 x 1'/z — 1,460 1,46(J 1,460 — 1.11U i,1 10 1;110 BC THA218-2; 16 31/a 1711tis :8� 2 — (4)0.162 x 31/2 (2) 0.162�x31/2 (6) 0.148 x 3 . _= ' 1960. 1,995 1,995 — ;490 <,515' 1,515 FL, THA222-2 16 3'/s 22Ys 8 I 2 — (4) 0.162 x 31/2 (2) 0.162 x 31/2 (6) 0.148 x 3 — 1,960 1,995 1,995 1,490 1.515 1,515 LA THA413 ` =18 "� 3% 131A6 41/2 ,1 2' — (4),0.148 x 3 (2) 0.148 x 3 (4) 0.148 x 3 '1 630 _ — 1,165 1:165 ;165 THA418 16 3% 171/2 77/a 2 — (4) 0.162 x 31/2 (2) 0.162 x 31/2 (6) 0.148 x 3 — 1,960 1,995 1,995 — 1,490 1,515 1,515 =THA422 ", -i6 3s/a : 6 22 77%3 2 " (d) 0162 x 3Uz (2) 0162 x �3.1/2 (6) 0:148 x 3 — io ?fi t 0 1 nos =,d 37 THA426 14 3% 26 T% 2 — (4) 0.162 x 31/z (4) 0.162 x 31/2 (6) 0.162 x 31/2 — 2,435 2,435 2,435 — 2,095 2,095 2,095 THA422-2' 14 ` 71/4 2211/s 93/4 �" 2 — (4) 0162 x 31/2 (4) 0.162 x:8% (6) 0.162 x 31h '— 3,330 3,330 3 330 "� — _2,865 2,865 2,865 FL THA426-2 14 71/4 261/is 93/4 2 — (4) 0.162 x 31/2 (4) 0.152 x 31h (6) 0.162 x 31h — 3,330 3,330 3,330 — 2,865 2,865 2,865 1' , -z Faoe Blount (Max } Installation THA29 18 1 % 91% 51A — 91'ti6 — (16) 0.148 x 3 (4) 0.148 x 3 5525 2.265 2,265 2,265 450 1950 '1950 1950 THA213 'i 18 14%a 13s/is 5112 .= •131A6 - (14) 0.148'X 3 (410.148 x 3 5 ;2,3 . 2 1 _: 32,450 735 1760 2010 2105 THA218 18 1 sh 173/is 51h — 17-M6 — (18)0.148x3 (4) 0.148 x 3 855 2,450 2,450 735 2105 2105 2105 THA218 21 16 318 1711/16 8' ° —7 141ti6 (22) 0.162x31/z (6) 0:162 x.31x 1 $55 34f , 310 a , 310 . 5,595 2 ¢:4a Z,845 2.845 �' IBC, THA222-2 16 3% 223/is 8 — 141/+s — (22) 0.162 x 31/2 (6) 0.162 x 31/x 1,855 3,310 3,310 3,310 1,595 2,845 2,845 2,845 FL, LA THA413 18 ,3% 118161 41/2 -I — 13% — (14) 0.148'x3 (4J 0:148 x 3 ,8 ? 04 ? 34 ;..? 45 1 735 1,780 2 010 .2:105 THA418 16 3% 171/2 77/s — 106 — (22) 0.162 x 31/2 (6) 0.162 x 31/2 1,855 3.3-10 3,310 3,310 1595 2,845 2,845 2,845 THA422 ;, 161 3% 22 .77/ "— , ', 14% . " = _ -� (22) 0.162 x 31h (6) 0:1$2 x 31h 1, 855 1 3 10 s,110 ` s 310 1595 1.840 2,845' 2,8 45 THA426 14 3% 26 77/a — 161A6 — (30) 0.162 x 31/z (6) 0.162 x 31/2 1,855 4,415 4,480 4,480 1.595 3,795 3,855 3,855 THA422-2, ]4 '71/4 22t1/s 9�K -- 16% — (30) 0.162 x 31h 1(6) 0.162 x 31h l=,"855 5,170 5 520 i'5 520 1,595 4,445- 4,745 4,745 FL THA426-2 14 ( 71/4 261/is 93/4 — 18 — (38) 0.162 x 3'h (6) 0.162 x 31h 1,855 5,520 5,520 5,520 1,595 4,745 4,745 4,745 1. Uplift bads have been increased for earthquake or wind Loading with no further increase allowed. Reduce where other loads govern. 2. Wind (160) is a download rating. S. Min. top flange refers to the minimum length of strap that must be field -formed over the header. The tabulated bads for the THA29 with 11h' min. top flange are based on a single 2x carrying member; all other top -flange installation bads are based on a minimum 2-ply 2x carrying member. For 4x2 truss carrying members with double top chords, use the specified fasteners for full tabulated values. For single 4x2 top chord or nailer applications, refer to the Nailer Table. 4. Face -mount installation bads are based on a two-ply 2x carrying member minimum. For single 2x carrying members, use 0.148' x 1 W nails in the carrying member and tabulated fasteners in the carried member, and use 0.80 of the table value for 18 gauge, and 0.68 of the table value for 16 gauge and 14 gauge. 5. For the THA 2x models, one strap may be installed vertically according to the face -mount nailing requirements and the other strap wrapped over the truss chord according to the top -flange nailing requirements (see drawing on p. 186) and achieve full tabulated top -flange installation loads. 6. Refer to installation instructions regarding fastener installation into carried Ooist) member. Based on the installation condition, nails will be installed either straight with straighted double -shear nailing tabs or slanted. 7. Fasteners: Nail dimensions in the table are fisted diameter by length. See pp. 21-22 for fastener information. Simpson Strong-De®.Wood Construction Connectors Face -Mount Joist Hangers �j This product is preferable to similar connectors because of a) easier installation, b) higher loads, c) lower installed cost, or a combination of these features. The deuble-shear hanger series, ranging frorn the ligh capacity LUS hangers to the highest -capacity ; iGUS hangers, feature-, innovative double -shear nailing that. distributes the load through two points on each jo st nail for greater strength. This allows for fewer nails, faster installation and the use of all common nails for the same connection. For medium -load truss applications, the MUS offers a lower -cost alternative and easier installation than the HUS or THA hangers, while providing greater load capacity and bearing than the LUS. Material: See tables on pp. 194-195 Finish: Galvanized. Some products available in stainless steel or ZMAX® coating. See Corrosion Information, pp.13-15. Installation: • Use all specked fasteners; see General Notes. • Nails must be driven at an angle through the joist or truss into the header to achieve the table loads. • Not designed for welded or nailer applications. Options: • LUS and MUS hangers cannot be modified • Concealed flanges are not available for HGUS and HHUS • Other sizes available; consult your Simpson Strong -Tie representative Codes: See p.12 for Code Reference Key Chart m Double -Shear Nailing Top View Double -Shear Nailing Side View Do not bend tab ?? Dome Double -Shear Nailing Side View t ` (Available on some models) 1' for 2x's 1'Ae"for4x's� fl a_ ? a, B LUS28 HHUS210-2 elm MUS28 4 ,o >o c' HUIS210 (HUS26, HUS28, and HHUS similar) 0 a- sa ° HGUS28-2 Typical HUS26 Installation with Reduced Heel Height (multiple member fastening by Designer) r•'1 193 Simpson Strong -Tie° Wood Construction Connectors Face -Mount Joist Hangers (cont.) Model No Min Heel Height �Ga. Dimensions (in.) Fasteners W , ,' -H3 �B Carrying: Member e Carried Member . Single 2x Sizes LUS24 2W.r '18` 19/is.` ".3'/e ;13/4 ,.(4)0.148x3;`' (2)0.148x3 LUS26 4?ra , _ 19/6 .' 43/4 13/a . ., ,(4)0.148 x 3 - " ' (4)10.148 x 3 MUS26 47MG 18 19/16 51i6 2 (6) 0.148 x 3 (6) 0.148 x 3 HUS26 46/i6 16 1 % 53/a 3 (14) 0.162 x 31/2 (6) 0.162 x 3'/2 HGUS26 4%4 12 1 % 5%, 5 . `(20);0.162 x 31/2` (8) 0.162.x 31/2 WS28 43/s ,18_ 1 %6 66i'a 13/a ' ° (6) 0.148 x 3 -(4) 0.148 x3' MUS28 65A6 18 19A6 613A6 1 2 (8) 0.148 x 3 (8) 0.148 x 3 HUS28 61/2 16 1 % 7 3 (22) 0.162 x 3 (8) 0.162 x 3'h HGUS28 69A6 12 1 % 71/a 5 (36) 0.162 x 31/2 (12) 0.162 x 31/2 LUS210 41K 18 19/,6 '713 / 13/. (8)08x3 (4) 0.148x3 HUS210 8% 16 16/a _911 3 (30) 0,.162 x 31/2 (10) 0.162 x 31/z HGUS210. 8%/ 12 15e ' 6ma 5 (46);0.162 x 3lii (16) 0.162 x 3yk ' 1. See table below for allowable loads. These products are available with additional corrosion protection. For more information, see p.15. ® For stainless -steel fasteners, see p.21. Many of these products are approved for installation t with Strong-Drivell SD Connector screws. See pp. 335-337 for more information. a " s OF Allowable Loads : SP Allowable Loads SPF/HF Allowable Loads code Model No U,phfti146oi:f��Snduu (1,00)=�(113) ,Roof:: (125)i „Wmd ;; (160)`; Upliftl°floor,Fo ` (160), (100)15) ow" Roof .-(125) Wind° (160) llpliftl "`F(160) Floor (100) _.. Snow '.(115) Roof ` ,Wind (125): (160) _ Ref. Single 2x Sizes LUS24.. �76 . ._820 _1,045s'-.7?.5 t825. 890 _ '1, 0 . 360' 495��"° 565; 605" `, 770 �i LUS26 1,165 865 990 1,070 1,355 1,165 935 1,070 1,150 1,475 865 635 725 785 1.000 IBC, FL, Tv1US26 295 1430 1 560 1 zu,,; 930 " " 1,405 a60 1; I60 1;5i0 . 81t 955 1090� 1,180 j 35 LA HU526 1,520 2,735 8,095 3,235 ID ED 19 1. For dimensions and fastener information, see table above. See table footnotes on p. 195. HHUS/HGUS See Hanger Options information on pp.98-99. HHUS - Sloped and/or Skewed Seat • HHUS hangers can be skewed to a maximum of 45° and/or sloped to a maximum of 45' • For skew only, maximum allowable download is 0.85 of the table load • For sloped only or sloped and skewed hangers, the maximum allowable download is 0.65 of the table load • Uplift loads for sloped/skewed conditions are 0.72 of the table load, not to exceed 2,475 lb. • The joist must be bevel -cut to allow for double shear nailing HGUS - Skewed Seat • HGUS hangers can be skewed onh, to a maximum of 45°. Allowable loads are: HGUS Seat Width Joist Down Load Uplift W < 2" Square cut 0.62 of table load 0.46 of table load W < 2" Bevel cut 0.72 of table bad 0.46 of table load 2" < W < 6" Bevel cut 0.85 of table load 0.41 of table load 2" < W < 6" Square cut 0.46 of table bad 0.41 of table load W > 6" Bevel cut 0.85 of table bad 0.41 of table load Acute 'side apeeuy dnyie Top View HHUS Hanger Skewed Right hoist must be bevel cut) All joist nails installed on the outside angle (non -acute side). 194 LUS/MUS/HUS/HHUS/HGUS These products are available with For stainless 10 additional corrosion protection. ® steel fasteners, For more information, see p.15. see p. 21. SS> e Many of these products are approved for installation 9 with Strong -Drive° SD Connector screws. See pp. 335-337 for more information. Model " No -� -Height Mm.. Heel Ga z, - 'Dimensions (in) W N e Fasteners {In) Carrying"_" Carried 'Member : Member DF/SP Allowable Uplift Flaor;'Snow ;(160) (100) ; Loads Roof Wmd `(115) (125) (160) SPF/HF Allowable loads Uplift.'Floor Snow` Roof Wrrid (160) (100) (115) ; (125) (160) Code ; Ref. Double 2x Sizes LUS244,'' 2'14- 18 3'/e; 3�/s' 2 �'(4) 0.16Z 3'h '','(2)•0.1620,1/z =-�:7,C� 80Q-; 905..,'�80 ,1;245, 355 + -690 : 780': 845 '-1,070 LUS26 2' -49/eh .18-; 31/e ,4?/e '"2 (4) 0;+7_62x3Yz,;',(4) 0.162 X3'z . l,i)(jv, 1,030 „1,170, 1;265 1�595; 910 885 1;005` 1,0901,370> HHUS26-2 06 14 3% 5% 3 (14) 0.162 x 31/2 (6) 0.162 x 31/2 1,320 2,830 3,190 3,415 4,250 1,135 2,435 2,745 2,935 3,655 HGUS26-2 49/6 12 35/16 57Ar 4 (20) 0.162 x 31/2 (8) 0.162 x 31h 2,155 4,340 4,850 5,170 5,575 1,855 3,730 4,170' 4,445 4,795 WS28 2= .'. '49h6 18- 31A- • 7 2 (6)•0162x31h, '' (4) 0.162,z31h 1,4E 1315j ;i 490,, i 1,610 '2,030,.�910 1;130 1;280`'1,38&: 1,745 IBC, FL, HHUS28 2 69Ji6, 14 , 35ti6 "7?/a 3 .(22)'0162 x 31h ` �_ {8) 0.162 �X 3'h 1 .^'<80 4 265: 4 8101 5;15& .5,980' 1,515 , '3;670a 4,135, 4,435 514'5, LA HGUS28- >6s/�6' 12 ; 3:%16 736.. 4 RUJ 62 01/V; ,(12) 0.162 x 31/23,235 7,460 �7,460 17,46D ,7,460> "2,780, 6,415 6,415 6,415 6,415 LUS210-2 6346 18 31k 9 2 (8) 0.162 x 31/2 (6) 0.162 x 31/2 1,445 1,830 2,075 2,24.5 2,830 1,245 1,575 1,785 1,930 2,435 HHUS210-2 8-% 14 3-Aa 87/a 3 (30) 0.162 x 31/2 (10) 0.162 x 31h 3,550 5,705 6,435 6,485 61485 3,335 4,905 5,340 5.060 51190 HGUS210-2 89/r6 12 3546 93/i6 4 (46) 0.162 x 31iz (16) 0.162 x 31/2 4,095 9,100 9,100 9,100 9,100 3,520 7,460 7,825 7,825 7,825 Triple 2x Sizes HGUS26-3 �12 41,�s 51/2, _A (20)'0�162�x3'Iz",, (8)0.16Zz3%2 2155 4340 4�85D 51'70 55, ,1;555 3730 4,170� 4,445 ;4,795` IBC, FL, HGUS283 y-61�96" `12 41 a 7?(1 ' ��4 .,(3�)4162­111x31%2 ,(12)0.182z31h 3,238 7,4609 7460 7460 7460: 2;780"'6415 6.415 6,415 6,416- LA HHUS210-3 83/s 14 41%6 87/a 3 (30) 0.162 x 31h (10) 0.162 x 31h 3,405 5,630 6,375 6,485 6,485 2,930 4,840 5,485 5,575 5,575 FL HGUS210-3 VM6 12 0`46 91/4 4 (46) 0.162 x 31/2 (16) 0.162 x 31h 4,095 9,100 9,100 9,100 9,100 3,520 7,825 7,825 7,825 7,825 HGUS212=3 - ­ 1`05W , 12 - 4"Vit 10-14 (56) 0162 X ' 1h- (20) 9.162=x 31h ,'691 9,04 . "45, 9,()45' 9,Od5 47900 7,780 7,780 7. 7,780 IBC, FL, LA HGUS21473 12 a " ,12 41* .123/4 ;4.. ,(66j 0162 x 3'h- ,(22)'0.162 x 31h 5;695' 10;125 10125, 10125 r10;125 4,900 8,190 8190., ,8;190 :8;190 Quadruple 2x Sizes HGUS26-4 I; 511h s �12 6946 5346' ='4 ' (20) O j62'z 31/2 - 8) 0.11. 62 x 311W 4155 4 340, =4 850 5,170 5,575' -1,855' 3,730 ,4,170' 4,445', 4,795 IBC, FL, HGUS28-4 71/4 12 61A6 73A6 4 (36) 0.162 x 31/2 (12) 0.162 x 31/2 3,235 7,460 7,460 7,460 7,460 2,780 6,415 6,415 6,415 6,415 LA HHUS210-4 83/a 14 61/s 87/s 3 (30) 0.162 x 31h (10) 0.162 x 31h 3,405 5,630 6,375 6,485 6,485 2,930 4,840 5,485 5,575 5,575 FL HGUS210-4 . " 91/4"� 12" - 69A6 9'/i6. `,4" " (46)0162 x 31/z ' (16) 0.162 X 31h 4,095 9100s �9,100 j 9,100 , 9,100� 3,520 7,825 7,825. 7,825 .7,825 HGUS212-4 '105h. '12 69h6 10% '4 (56)0162x3'/x' (20)0162"ic31h ,t9> 9,(}17, `15,";1,(l4' 9,(�r� 9(}0 7/rs0 7.780 t,780 /780 IBC, FL, LA 25ia 12 1 A 4 (66) 161/i(22)`0.162 , $ 10 8,710 8,710•-HGUS214= 4x Sizes LUS46 4%.. 18-. 39�6,"43/4' >'2 .'.(4)0.162x31h ,(4)0.162x3M2 !`,66 1030 j,1170, 1"265.17,595:' 910 5885 =1,005, 1.090'' 1;,370 IBC, FL HGUS46 = 4346--- -12 31/a 47A6 4 '(20) 6162�x 31/z: `(8) 0.162 z 31h , 2155 4,340 :,4 $50, 5170 5 575 1;855 ;3730 4,1704 4;445' i4,795 HHUS4(i ') 45ie� "14, 35% 53/6 '3 ' (14} 0102 x 31/2 (6) 0'.162 z 3re 1 2 83Qz 3190+ :3;4 4 2b0'I 11 5, 2;435 2,745" ,935' _$,655 LUS48 43/s 18 39A6 63/4 2 (6) 0.162 x 31h (4) 0.162 x 31/2 1,060 1,315 1,490 1,610 2,030 910 1,130 1,280 1,385 1,745 IBC, FL, HUS48 61/s 14 39/6 7 2 (6) 0.162 x 31h (6) 0.162 x 31h 1,320 1,580 1,790 1,930 2,415 1,135 1,360 1,540 1,660 2,075 LA HHUS48 61h 14 3% 71/8 3 (22) 0.162 x 31/2 (8) 0.162 x 31h 1,760 4,265 4,810 5,155 5,980 1,515 3,670 4,135 4,435 5,145 HGUS48 67A6 12 3% 711A6 4 (36) 0.162 x 31h (12) 0.162 x 31/2 3,235 7,460 7,460 7,460 7,460 2,780 6,415 6,415 6,415 6,415 Wwo 3 ­:61/4 ;,` `18 39h6 83/4 ; ";2 (8)�a j62.01/2 ? ' (6) 0.162 X 31h. h;44 1 830, 2 075 2;245 2 830 7 245, �1,575 1 JW1 1,930', ,2,435 HHUS410 `. :"83/e' 14 .39%' 9 .` 3 (30) 0 . x 31h" (10) 0.162 z 31h a 650 5 705 16 435 8,4fis G 485' '..c65 4 905 5,535 a,,,, 5' 5,575' < - 8? ti, -I1 31 31h4 ,0_9.5. 91 3,520, .7,825 .7,825 7,8257'25HGUS410. , LA HGUS412 107AG 12 35A 107A. 4 (56) 0.162 x 31h (20) 0.162 x 31h 5,695 9,045 9,045 9,045 9,045 4,900 7,780 7,780 7,780 7,780 HGUS414 117A6 12 35A 127/% 4 (66) 0.162 x 31h (22) 0.162 x 31h 5,695 10,125 10,125 10,125 10,125 4,900 8,190 8,190 8,190 8,190 Double 4x Sizes HGUS7.37/10' - 87h6; 12 .: " 7,% S ti61 �'4 , 7(46) Q.162 X -31h `(16) 0?62'z q1W 3,430 9,095 ;9,695, 9,`095- .9;095. 2' 50 7,820 f 7,820' ,7,820 �7,820'. ,HGUS7.37/12 ,.107A6 12 7%' 10946 4. (56)0€16,2 z 31h (20),0162 c 31h. 3 835 9,24 9 295 9;295 '9,295' 3,30, 7;995 7,995: . 7;995' .7,995' FL KUS7.37/14" ',_MA, 12 - .7% 12% `4 1 '(66) Or162,z 31/2• (22) 0:162;01h 5;080 10 500 ]0 500 10 500 10,500 4,370 9,030 1 9,030. 9,030 9,036 1. Uplift bads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern. 2. Wind (160) is a download rating. 3. Minimum heel height shown is required to achieve full table bads. For less than minimum heel height, see technical bulletin T C-REDHEEL at strongtie.com. 4. Truss chord cross -grain tension may limit allowable loads in accordance with ANSI/TPI 1-2014. Simpson Strong-Tiee Connector Selector® software includes the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie. 5. Loads shown are based on a two-ply 2x carrying member minimum for nailed hangers. With 3x carrying members, use 0.162" x 21/2' nails in the header and 0.162" x 31h" in the joist, with no load reduction. With single 2x carrying members, use 0.148' x 11h" nails in the header and 0.148" x 3" in the joist, and reduce the load to 0.64 of the table value. 6. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. ems, 195 HTU Face -Mount Truss Hanger The HTU face -mount truss hanger has nail patterns designed specifically for shallow heel heights, so that full allowable loads (with minimum nailing) apply to heel heights as low as 37/s". Minimum and maximum nailing options provide solutions for varying heel heights and end conditions. Alternate allowable loads are provided for gaps between the end of the truss and the carrying member up to 1/2" max. to allow for greater construction tolerances (maximum gap for standard allowable loads is 1/6" per ASTM D1761 and D7147). See technical bulletin T C-HANGERGAP at strongtie.com for more information. Material: 16 gauge m Finish: Galvanized i 0 Installation: Use all specified fasteners; see General Notes Can be installed filling round holes only, or filling V round and triangle holes for maximum values N See alternate installation for applications using the HTU26 on a 2x4 carrying member or HTU28 or HTU210 on a 2x6 carrying member for additional uplift capacity Options: 0. • HTU may be skewed up to 671/2'. See Hanger Options on pp. 98-99 for allowable loads. • See engineering letter L-C-HTUSD at strongtie.com for installation with Strong-Driv& SD fasteners. Codes: See p.12 for Code Reference Key Chart 196 Min. heel height pertable Many of these products are approved for installation with Strong-Dr'iveo SD Connector screws. See pp. 335-337 for more information. HTU26 11m truss and carrying member HTU Installation for Standard Allowable Loads (for 1/2" maximum gap, use Alternate Allowable Loads.) Standard Allowable Loads (1/8" Maximum Hanger Gap) Typical HTU26 Minimum Nailing Installation Altemate Installation - HTU28 Installed on 2x6 Carrying Member (HTU210 similar) Min •. Model . Heel No. Helgbt -Dimensions (in) Fasteners:(m) , Carrying ;Carried W r H 8"' ;Member 4=Merdber 3 DFISP Allowable loads Uplift Floor, ,Snow "hoof Win n(160)', ,(100) + (115) {125)„ ';(160)". �SPF/HF Allowable Loads •Upliff„ Floor Snow Roof," Wind (160); (100} (115) (i25)" , (760) Code Ref. " Single 2x Sizes HTU26 31/2, "15h 57Is 31h: (20) 0.162 x 31h" .(11) 0.148 z 11/z , i645 2,nZu .�,E70. 'D2 e .0 , z;670, 550 680 . ,a"a0 1;680 " i,686 HTU26 (Min.) 37A, " 15/8 57A6' Th .l '(20) 0.162 x"31/z (14) 0.148 x 1112 1250„ 2,940° :-3,200 : 3y200 ; 3;20o: 1,075, 1,852 2,015 2,015 2,015 HTU26 (Max.) 51h " 1 a `' 57/is 31h" (20) 0.162 x 31h '=(20) 0148 x11h 1,555 :2i940 f.^2: , :z; 80 - -4 i 010 ` 1,335`" 2,530 -.. Z855 3,080 : 3,450 IBC, HTU28 (Min.) 37/8 15/8 71As 31h I (26) 0.162 x 31/2 (14) 0.148 x 11h 1,235 13,820 3,895 3,895 3,895 1.060 2,865 2,920 2,920 2,920 FL, HTU28 (Max.) 71/4 15/s 71As 31/2 (26) 0.162 x 31/2 (26) 0.148 x 11h 2,020 3,820 4315 4.655 5,435 1.735 3,285 3,710 4,005 4,675 LA HTU210 (Min.) 3Us : J SA',, 91A6 31/z ".(32) 0.162 x 31h =(.i4) 0.148'x11h 1;330` �,3'0 ; `' ,300., r-;300 _4;36, 1,145 3,225 �;220 3;225 :3,225 HTU210 (Max.) 91/4 15/11 1 9?46 1 Th 1(32) 0.162 x 31h :(3210.148 xs11h ;3;315, 4,705 - ~' 10 - 5 730" f5 995' 2,850 4,045 4.565 4,930 ;5,155 Double 2x Sizes HTU26-2 (Min'.) A : 35 6 ' 57/ts- 31h 1 `(20) 6.162 x 31h _ �(14) 0148;x3 .1,515• ,2 946 =,3 42 . .3;580 3 910 � 1,305= 1,850 ; 2,090 '2 255' 2,465, HTU26-2 (Max,) 5 hh_ .3%h "57As' 31h , " (20) 0.162 x 31h ; 20G� -0.148 x'3 -;2,1'7,5 � 2;940; „ ;,3?fi , ,. : x0. t k 4480." .1,870 2,530 `24855 081:.3;855 HTU28-2 (Min.) 37/8 3`341s 71A6 31h (26) 0.162 x 3Y2 (14) 0.148 x 3 1,530 3,820 4,310 4,310 4,310 1,315 2,865 3,235 3,235 3,235 166. HTU28-2 (Max.) 71/4 35As 7116 31h (26) 0.162 x 31h (26) 0.148 x 3 3,485 3,820 4,315 4,655 5,825 2,995 3,285 8;710 " 4 0f15 ",010 FL, LA NTU210-2-(Min) " 3%"; ° 3% 91A6" ,3 1,1 (32) 0.162 x 31h ° '<(14) 0.148x 3 " 4:,7555.4J054 4 815..4 815 ' -41815. 1,510. 13,530, 3,610 3,610 3.610' HTU210.2(Max.) I 91/¢ : 35As= 91,16 3112. .(32) 0.162 x 31/2 ,(32) 6.148°x 3 , 4,i16 14,71061 ' o,a13 5 3u f,51) 3,535 41045' 4 565 4,93 0 5 605- 1. The maximum hanger gap is measured between the joist (or truss) end and the carrying member. 2. Minimum heel heights required for full table bads are based on a minimum 2;12 pitch. 3. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern. 4. Wind (160) is a download rating. 5. For hanger gaps between 1/8' and 1h°, use the Alternate Allowable Loads. 6. Truss chord cross -grain tension may omit allowable loads in accordance with ANSVTPI 1-2014. Simpson Strong -Tie" Connector Selector"' software includes the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie. 7. Loads shown are based on a minimum two-ply 2x carrying member. For single 2x carrying members, use 0.148' x 11h° nails in the header and reduce the allowable download to 0.70 of the table value. The allowable uplift is 100% of the table bad. 8. Fasteners: Nail dimensions in the table are fisted diameter by length. See pp. 21-22 for fastener information. HTU Face -Mount Truss Hanger (cont.) Many of these products are approved for installation with Strong-DriveQ9 SD Connector screws. See pp. 335-337 for more information. Alternate Installation Table for 2x4 and 2x6 Carrying Member -Min. Fasteners (in) DF/SP Allowable Loads �' SPF/HF Allowable'sLoads Minimum Model No. Heel Height Carrying Carrying Carried ` Uptrft j Floor `Snow " Roof ` Wind, ,Uplift Floor Snow. Roof Wind Code Ref. (in.) Member ) Member Member, _ (160) (100) 715) (125) ` (1611), , "-(160) (100) (115) (125j (160)-` HTU26 (Min.) 37/s (2) 2x4 (10) 0.162 x 31h (14) 0.148 x 11/2 925 1,470 1,660 1,790 1,875 795 1,265 1,430 11540 1,6 i5 HTU26 (Max.) 51h (2) 2x4 (10) 0.162 x 31/2 (20) 0.148 x 11/2 1,240 1,470 1,6630 1,790 2,220 1065 1,265 1,430 1,540 1 01:0 IBC HTU28 Max. 71/4 2 2x6 20 0.162,x-3Yz 26 0.148x1112 „1,970-- 2,940' "3,120' 3',5 3. 3;905" 1;695 2,530 - 2:855 1',C80 ; 3,360 FL, LA HTU210 (Max ), 91/4 (?) 2x6 �'(20) 0.162 01/ (32);0148 x T1h 2 7fi0 2 940 3:'20 158 3 905„ 2,375 2,530 _ 2,855 `3,C80 ',3,360 1. See table above for dimensions and additional footnotes. 2. Maximum hanger gap for the alternative installation is 1h". 3. Wind (160) is a download rating. 4. Fasteners: Nail dimensions in the table are F.sted diameter by length. See pp. 21-22 for fastener information. Alternative Allowable Loads (1/2" Maximum Hanger Gap) Min. Dimensions (in.) Fasteners (in.) DF/SP Allowable Loads:' SPF/HF Allowable Loads Model No. Heel Height . W H g Carrying _ Member Corned " - Member Uplift (160) ;.Floor (100) A.a Snow (115) Roof (12b) Wind'] (160) ; Uplift (16D)' Floor (100) , - Snow (115) Roof (125) Wind (160) Code Ref. Single 2x Sizes HTU26 31/2 14 57fs 31h I.(20) 0.162 x 3'/r (11j 0;148 x11/z 6'5 :'2 �95 f s?5 ?,395.' 2 �95 545 . 14'.0 1,517 . -1,510 1:510 HTU26(Min);=- 371e 1ga , 57fs- 31h " (20)0.162.x31/z (14j0.148x=111 i 175 2940 3iDD, 3100; 3100 1,010 '1955 1,955 1,955 1,955 H i U26 (Max.} ` = 51h ' 16/e 57/s 3Yz (20) 0.162 x'3?/z (20) 0.148 x 11/z 1 215 2 940 9 3 5 "10 130 1,045 1,850 �.090 ?,285 ' ?_,?85 IBC, HTU28 (Min.) 31k 1 % 71ti6 31h 1 (26) 0,162 x 31/2 (14) 0.148 x 11h 1,110 3,770 3,770 3,770 3,770 955 2,825 2,825 2,825 2,825 FL, HTU28 (Max.) 71/4 1 % 711A6 31h (26) 0.162 x 31/2 (26) 0.148 x 11h 1,920 3,820 4,315 4,655 5,015 1,695 2,865 3,235 3 A90 3,765 LA HTU210 (Min.)1 37h 15% ' 9M6 31h (3 2) 0,162 x 31/2 (14) 0:148 x 11h 1 250 3;600 3 60 3,600 3 600 1,075 2,700 2;700 2,700 2,700 HTU210.(Max.) 9'/a 16/a. 9A6 31h (32) 0.162 x'31/2a `,(32) 0.148 x 11h 3 256" -4,705 5 020 5 020', 020 2,800 '3,530 3,765': 3,765 3,765 Double 2x Sizes 'HTU26-2 (Min)',, 37A 3% : 57Aa 31h (20) 0.162 x 3Yz (14)'0.148 x 3 ` i 515 2 94D, a 32, ,3,500 , 3 500,; 1,3051 2,205 2,205 2,205 2,205 HTU26-2 (Max.) _,. 51h ' 3 hfi 57& 31/2 (20) 0.162-x!31/x - (20) 0.148,x 3 1910 2,940. 3'3210 3 500'y 31500 - 1,645 2,205 -2,205 2,205 2,205 HTU28-2 (Min.) 37/e 34'i6 711A6 31h (26) 0.162 x 31/2 (14) 0.148 x 3 1,490 3,820 3,980 3,980 3,980 1,280 2,865 2,985 2,985 2,985 IBC, HTU28-2 (Max.) 71/4 3 V1 6 711A6 31h I (26) 0.162 x 3% (26) 0.148 x 3 3,035 3,820 42315 4,655 5,520 2,610 2,865 3,235 3.490 4,140 FL, LA HT6210-2 (Min.) ( 3'% 3% 91f6 31h , (:(32) 0.162 x'31/2, 1, (14) 0.148 x 3 1 755 4;255 4;255 4 255' 4 2b5 • 1,510 3,190 3,190 3,190 3,190 HTU210-2 (Max) " `911A 1 8% 9'% 31h I (32) 0.162 x3112 "-(32) 0.148 x 3 3 $55 4705 5 a r ` 71j1 6 47D;< -3,315 3,5,30 3,980 4,300 4,855 1. The maximum hanger gap is measured between the joist (or truss) end and the carrying member. 2. Minimum heel heights required for full table bads are based on a minimum 2:12 pitch. 3. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern. 4. Wind (160) is a download rating. 5. For hanger gaps between %" and 1h°, use the Alternate Allowable Loads. 6. Truss chord cross -grain tension may limit allowable loads in accordance with ANSkTPI 1-2014. Simpson Strong -TO Connector Selector® software includes the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie. 7. Loads shown are based on a minimum two-ply 2x carrying member. For single 2x carrying members, use 0.148" x 1 V nails in the header and reduce the allowable download to 0.70 of the table value. The allowable uplift is 100% of the table bad. 8. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. A 197 SimpsonStrong-Tie° Wood Construction Connectors Medium -Duty Face -Mount Hangers HU/HUC hangers may be installed on a masonry/concrete wall as described below. Additionally, HU hangers with one flange concealed may be installed similarly. HU and HUC products are heavy-duty face -mount joist hangers made from 14-gauge galvanized steel. • The HUC is a concealed flange (face flanges turned in) version of the HU. • HU is available with both flanges concealed, provided the W dimension is 25/is" or greater, at 100% of the table load. Specify HUC. • HU is available with one flange concealed when the W dimension is less than 25/16" at 100% of the table load. Specify as an 'X' version and specify flange to conceal. • For any HU or HUG shown in this catalog, the user may substitute all face nails with 1/4" x 1 3/4" TitenO 2 screws (Model-fTN2-25134H) for concrete and <" x 2g41' Titen 2 screws (Model -11 N2-25234H) for GFCMU. Follow all installation instructions and use the loads from the savin lumber or B.NP sections. Material: 14 gauge Finish: Galvanized; ZMAX° and stainless steel available Installation: • Attach the hangers to concrete or GFCMU walls using hex -head Titen 2 screws. Titen screws for GFCMU (1/4" x 23/4" — Model TTN2-25234H) and for concrete (1/4" x 1 %" — Model TTN2-25134H) are not provided with the hangers. • Drill the 3/1s"-diameter hole to the specified embedment depth plus 1/2". • Afternatively, drill the 3/s"-diameter hole to the specified embedment depth and blow it clean using compressed air. • Caution: Oversized -diameter holes in the base material will reduce or eliminate the mechanical interlock of the threads with the base material and will reduce the anchor's load capacity. • Titen Installation Tool Kits are available. They include a 3/is" drill bit and hex -head driver bit (Model TTNT01-RC); a 3/18 x 41/2" drill bit is also available (Model MDB18412). • A minimum edge distance of 11/2" and minimum end distance Of 37A" is required as shcroin in Figure 1 for full uplift load. • Where no uplift load is required, a minimum end distance of 11/i' is penritted. Codes: See p.12 for Code Reference Key Chart Concealed flanges HUC410 1 ile edge Ji I HU214 Figure 1 — HUC410 Installed on Masonry Block End Wall Figure 2 — HUC410 Installed on Masonry Block End Wall rA L 0 d C '0O r_U Al d O v to r— � V 237 HU/HUC/HSUR/L ­_ . . . . ... . .. . .. . . ... .. . .. . . ........... . ...................................... ­­­­ .......... . ............ ___­ ............. ­­ .............. . .. ..... ...... . ..... .................. . ­__­ . . .. . ................ Medium -Duty Face -Mount Hangers (cont.) 05 These products are available with additional corrosion protection. For more information, see p. 15. I tdners = . ...... ..... . Allowable Loads 6F i n. V - Concealed. GFCMU ConcreteStandard Joist P -,f:pqwq 'PPI own TitenO,2,:�_' .12 HU26 HU26X (4) 1/4 x 23/4 (4) 1/4 x 13/4 (2) 0.148 x 11/2 335 1,000 335 1,545 HU28 HUAk 1/4-x 23!� P' 'j,� x 3 6) 1 (4)0.14 x 1112 8, r'7*� 1�§00 2400 HU24-2 HUC24.2 (4) 114 x 23/4 (4) 114 x 13/4 (2) 0.148 x 3 380 1 1,000 380 1,545 �HU2&'2�(Max)HUC 2&'2--,-, �(12)10 2,1�4,� il �/4 (6) 0,148 x 3 ...... ............ ;'d 6 HU26-3 (Min.) HUC26-3 (Min.) (8) 1/4 x 23/4 (8) 1/4 X 13/4 (4) 0.148 x 3 760 2,000 760 3,200 HU26-3 (Max.) HUC26-3 (Max.) (12) 114 x 23/4 (12) 1/4 x 13/4 (6) 0.148 x 3 1,135 3,000 1,135 3,950 HU28'-2 (Min.)'_(10) 1/4 23/4 4 4 x1 3/ (4) 0.148 x 3 500: HU2�-2'�Mex.)_, �PC2872 (Max.) NN4 (6,0.14 8'x 3 :�-,:11,135 �!i HU210 HU21OX (8) 1/4 x 23/4 (8) 1/4 x 13/4 (4) 0.148 x 11/2 545 2,000 760 .2,415 HU210,-2 Min. '2 (Min:) HUC210- 4 X 13 • (6) 0.148.x 3 �j "'13 0"', 86�,� -'_�i-,4;920 HU210-2 (Max�.) HUC210-2 (Max.)_ (18) lax 2,3/4 (1 -114: (10)0.1 x 3 1 00, "'4 500 1 80V HU210-3 (Min.) HUC210-3 (Min.) (14) 1/4 x 23/4 (14) 1/4 x 13/4 (6) 0.148 x 3 1,135 3,500 1,135 4,920 HU210-3 (Max.) HUC210-3 (Max.) (18) 1/4 x 23/4 (18) 1/4 x 13/4 (10) 0.148 x 3 1,800 4,500 1,800 5,085 HU212 ,ijl.1212X '(10) "A X:? �/4, 1 %1�,x?lii44 (6 )'0.148 x "1/2'­" 1 �..'l "",:: ���2 500"" .......... 5'�' 2665 HU212-2 (Min.) HUG212-2 (Min.) (16) 1/4 x 23/4 (16) '14 X 13/4 (6) 0.148 x 3 1,135 4,000 1,135 4,920 HU212-2 (Max.) HUC212-2 (Max.) (2 2) 1/4 x 23/4 (2 2) 1/4 x 13/4 (10) 0.148 x 3 1,350 5,085 1,350 5,085 HU212-3 (Min.) HUC2112-3(hiin.l (16) ?14 x 2 3K - (16) 1/4 x:1 � _' - (6)0.14 8x� 0060 -1 ��' I �­4;920 �U21�-S (Max�.)­. �0212 3 (Max:);11(22) 14X X 1 �14 1 0) 0.148 x 3':, : , 5 85�' I 800, ��5;085 HU214 HU214X (12)1/4 x 234 (12) 1/4 x 13/4 (6) 0.148 x 11/2 1,135 2,665 1,135 2,665 -HU214-2(Min.);; �IJU14-2 (Min.)`' -(18)1/4 x 244,.- t �(18)1v4 iaw�: X 8 0.148 x 3 1,11.1214�2'(Max.'I� HUC214�2 (Max.) .7 7 (24) 1/4 x 23/4'- '(24 4,X' 13/4 �_(12). 148x3 HU214-3 (Min.) HUC214-3 (Min.) (18) 1/4 x 23/4 (18) 1/4 X 13/4 (8) 0.148 x 3 1,515 4,500 1,515 5,085 HU214-3 (Max.) HU0214-3 (Max.) (24) 1/4 x 23/4 (2 4) 1/4 x 13/4 (12) 0.148 x 3 2,015 5,085 2,015 5,085 'HU216 �U216X' '(18) 1/4 x'23/4 ri 8) 1A X 11/4, (8) 0.148 x 1 15 . !�,,:2;920 ..... HU216-2 (Min.) HUC216-2 (Min.) (20) 114 x 23/4 (2 0) 1/4 x 11/4 (8) 0.148 x 3 1,515 4,920 1,515 4,920 HU216-2 (Max.) HUC216-2 (Max.) (26) 1/4 x 2Y4 (2 6) 1/4 x 13/4 (12) 0.148 x 3 2,015 5,085 2,015 5,085 HU216-3(Min 7y -��'HUC2164 (Min.)',(2 0) 1/4 x 2 3K (20),1/44 4 3/4 .1 3 (8) 0' 48 x 5 4 920;i 1515' 4920 HU216-3 (Maxi: HUC216-3 (Max.) (26)!/4,x23/4. 13/4, -(12) OA48 x 3 5,085; „2,015 5j()85 HU7 (Min.) (Not available) (12) 114 x 23/4 (12) 1/4 x 11/4 (4) 0.148 x 1112. 545 2,980 760 2,980 HU7 (Max.) (Not available) (16) 114 x 23/4 (16) 1/4 x 13/4 (8) 0.148 x 11/2 1,085 3,485 1,085 3,485 ' available) (Not 4,x 23/4:, B)'144 X -1 '/1 -6.148 x1 1h 23T��� 0 HU9 (Max)_T-NNot avallable) (24) ^I4 x 23/4 4' -,(10)P.148x,l' "44 735 35 HU11 (Min.) (Not available) (2 2) 1/4 x 23/4 (2 2) 1/4 x 13/4 (6) 0.148 x 11/2 1,135 3,230 1,135 3,230 HU11 (Max.) (Not available) (3 0) 1/4 x 23/4 (3 0) 1/4 x 13/4 (10) 0.148 x 1112 1,445 3,735 1,445 3,735 HU14 (Min.) (Not available) (28)1A:x 23/4:'- 4�x 1 P/4 (28)/ (8) 0 .14 8 x,1 112 5�:�� J'A 51 H U 14 (Max -4`-(Not available) (36) a23/4 '1' 1/4 x 13/4 X .1 :04) OJ48 Code-; Ref. 238 STAGGER JOINTS - TYP. RAISED HEEL ROOF TRUSSES B/SKIS F PLAN UPLIFT/SHEAR ANC EACH TRUSS - SEE PLAN aaa���a��a�iaaa�a�■ a�a�aaaaaa�aaa�aa� B/5KI f' NOTE: ADVL FRAMING NOT SHOIW FOR CLARITY RAISED HEEL TRUSS 5EARINGI'A1 BCALE, NTe SKI ROOF SHEATHING- SEE SOFFIT/FASCIA- SEE ARCI RAISED HEEL ROOF TRUSSES -SEE PLAN w a RIBBON BOARD- SEE SCHEDULE FOR SPACING t .IBBON BOARD- SEE FASTENING TO w N CHEDULE FOR SPACING ! TRUSSES ASTENING TO TRUSSES WALL SHEATHING -SEE PLAN -= MIN. 15/32' CDX PLYWOOD OR 1/16' OSB WITH Sd GUN NAILS -MASONRY WALL- (0.131' X 2 1/2') B 6' O.C. TO —UPLIFT HEAR GYP. CEILING- SEE PLAN RIBBON BOARDS ANCHOR EACH SEE PLAN / TRUSS- SEE PLAN SCHEDULE DO NOT FASTEN RIBBON BOARD INTO END GRAIN OF ROOF TRUSS MASONRY WALL - BOTTOM CHORD SEE PLAN RAISED HEEL TRUSS IBEARING B BGALE. NT0 SKI RIBBON 5CHEDULE DESIGN CRITERIA RIBBON MATERIAL RIBBON SPACING RIBBON ATTACHMENT vult=165 MPH (2)12d GUN (0.131' k 3') lVae MPH) 2X4 SPF02 24' TO EACH TRUSS, (4) EXP. XP1 B, ENCLOSED NAILS AT JOINTS Vult=180 MPH (2) 12d GUN (0.131' k 39 (Vasd=139 MPH) EXP. C, 2X4 5Ff'2 Ib' TO EACH TRUSS, (4) ENCLOSED NAILS AT JOINTS 2 imA a s �d �a is o 0 SNEET TITEE RNSEDHEY ROOF 1RU53Ef SNEU INFORMATION: ]BIIIB OAiEISSUFA. 11.0&IB [WAYM BT: RE`nflv®BT: M SK.1 ALPINE --ANITWCOMP.AW January 10, 2020 CarpenterContractors of America, Inc. 3900 Avenue G, NW Winter.Haven, FL 33880-6201 Dear Matt: Ithas come to my attention that some questions were raised concerning 5/8" diameter holes drilled thru the chords (wide face) ofsys42, gable end trusses to. allow for threaded rods used'for "tie'downs." If these gable ends are over continuous support` with one face fullysheathed and the hales are drilled about the centerline of the wide face no close than 4' O:C without :damaging any, connector plates or vertcal-webs then no repair is required.. The truss only supports. 2`feet of floor loads 'and no additional load.. If you have any questions, please give me a call. Sincerely, No. 86367 •' 11 . , STATE OF '.o,�` C 0R4�p'�,� Yoonhwak ( / f 0(nn 6750 Forum Drive, Suite 305, Orlando, FL 32821 - (800) 52.1-9790 - (863) 422-8685 www.alpineitmeom 111 01 1 A���fr �a Na. 86 • ° M1 STATE OFF 20 a w ®`+i �)l' AI. - 7wx docurnwt trtis boon electronic* siS W told s*WW using a 019W Signature. Pdrrtad copies wMwut an *rWkW sqnafum rrwst bs vsdfisd using firs original elacbonic vorslon. 16, ALPINE AN TTW COMPANY FL REG#'278, Yoonhwak Kim, FL PE #86367 :Siteinformation. Pa 1 Customer: Carpenter Contractors of America Job Number: N333986 Job Description: W/320 ,167ED ;RG01 11672/ARIAf4EAB ELEV.D Address: Alpine, an ITW Company 6750 Forum Drive, Suite 305 Orlando, FL 32821 Phone.,(800)755-6001 www.alpineitw.com Jab i~n tneern Criter,a. Design Code: FBC 6th Ed. (2017) tnteiliVlEW Version: 17.02.02A through 18.02.01A JRef # 1 WX189750051 Wind Standard: ASCE 7-10 Wnd Speed (mph) 160 Roof Load (psf) 20.00-7.00- 0.00-10.00 Building Type: Closed Floor Load s ; None. This package contains general notes pages, 27 truss drawing(s) and 5 detail(s). ifEtn Drawing Number -Truss 3. 1 216.20.1201.24472 Al 3 216.20.1156:58989 A2 5 216.20.1156.58723 A4 7 216.20.1157.00191 A6 9 216..20.1157.00299 A10G 11 216.2U 157.00642 A9 13 21'6.20.1156:59987 131 15 216.20.1156.59613 C1GE 17 216.20.1156.59659 MV01 19 216.20.1156.59441 ER 21 216.20.1157.00049 ERS 23 216.20.1156.59878 CJ5A 25 216.20.1157.00564 CJ3A 27 216.20.1156.59238 HJ7 29 A18015ENC101014 31' GBLLETIN1014 (tern ' Drawfri� Nu[rifier muss f f 2 216.20.1156.58864 A1A 4 216.20.1156.59302 A3 6 216.20.1156.59067 A5 8 216.20.1157.04090 A7 10 216.20.1157.04168 A8 12 216.20.1157.03981 A11G 14 216.20.1157,003.93 62GE 16 216.20.1157.03965 V4 18 .216.20.1157.00408 MV02 20 216.20.1157.00143 ERA 22 216.20.1156.59489 CJ5 24 216.20.1156.58957 CJ3 26 2,16.20.1156.59379 CJ1 28 A16015ENC101014 30 GBLLETIN0118 32 VAL160101014 0 Florida Certificate of Product Approval #FL1999 Printed 8/3/2020 1:06:20 PM 0 General Notes Truss Design Engineer Scope of Work, Design Assumptions and Design Responsibilities: The design responsibilities assumed in the preparation of these design drawings are those specified in ANSI/TPI 1, Chapter 2; and the National Design Standard for Metal Plate Connected Wood Truss Construction, by the Truss Plate Institute. The truss component designs conform to the applicable provisions of ANSI/TPI 1 and NDS, the National Design Specification for Wood Construction by AWC. The truss component designs are based on the specified loading and dimension information furnished by others to the Truss Design Engineer. The Truss Design Engineer has no duty to independently verify the accuracy or completeness of the information provided by others and may rely on that information without liability. The responsibility for verification of that information remains with others neither employed nor controlled by the Truss Design Engineer. The Truss Design Engineer's seal and signature on the attached drawings, or cover page listing these drawings, indicates acceptance of professional engineering responsibility solely for the truss component designs and not for the technical information furnished by others which technical information and consequences thereof remain their sole responsibility. The suitability and use of these drawings for any particular structure is the responsibility of the Building Designer in accordance with ANSI/TPI 1 Chapter 2. The Building Designer is responsible for determining that the dimensions and loads for each truss component match those required by the plans and by the actual use of the individual component, and for ascertaining that the loads shown on the drawings meet or exceed applicable building code requirements and any additional factors required in the particular application. Truss components using metal connector plates with integral teeth shall not be placed in environments that will cause the moisture content of the wood in which plates are embedded to exceed 19% and/or cause corrosion of connector plates and other metal fasteners. The Truss Design Engineer shall not be responsible for items beyond the specific scope of the agreed contracted work set forth herein, including but not limited to: verifying the dimensions of the truss component, calculation of any of the truss component design loads, inspection of the truss components before or after installation, the design of temporary or permanent bracing and their attachment required in the roof and/or floor systems, the design of diaphragms or shear walls, the design of load transfer connections to and from diaphragms and shear walls, the design of load transfer to the foundation, the design of connections for truss components to their bearing supports, the design of the bearing supports, installation of the truss components, observation of the truss component installation process, review of truss assembly procedures, sequencing of the truss component installation, construction means and methods, site and/or worker safety in the installation of the truss components and/or its connections. This document may be a high quality facsimile of the original,engineering document which is a digitally signed electronic file with third party authentication. A wet or embossed seal copy of this engineering document is available upon request. Temporary Lateral Restraint and Bracing: Temporary lateral restraint and diagonal bracing shall be installed according to the provisions of BCSI chapters B1, B2, B7 and/or B10 (Building Component Safety Information, by TPI and SBCA), or as specified by the Building Designer or other Registered Design Professional. The required locations for lateral restraint and/or bracing depicted on these drawings are only for the permanent lateral support of the truss members to reduce buckling lengths, and do not apply to and may not be relied upon for the temporary stability of the truss components during their installation. Permanent Lateral Restraint and Bracing: The required locations for lateral restraint or bracing depicted on these drawings are for the permanent lateral support of the truss members to reduce buckling lengths. Permanent lateral support shall be installed according to the provisions of BCSI chapters B3, B7 and/or B10, or as specified by the Building Designer or other Registered Design Professional. These drawings do not depict or specify installation/erection bracing, wind bracing, portal bracing or similar building stability bracing which are parts of the overall building design to be specified, designed and detailed by the Building Designer. Connector Plate Information: Alpine connector plates are made of ASTM A653 or ASTM A1063 galvanized steel with the following designations, gauges and grades: W=Wave, 20ga, grade 40; H=High Strength, 20ga, grade 60; S=Super Strength, 18ga, grade 60. Information on model code compliance is contained in the ICC Evaluation Service report ESR-1118, available on-line at www. icc-es. ora. Fire Retardant Treated Lumber: Fire retardant treated lumber must be properly re -dried and maintained below 19% or less moisture level through all stages of construction and usage. Fire retardant treated lumber may be more brittle than untreated lumber. Special handling care must be taken to prevent breakage during all handling activities. Page 1 of 3 General Notes (continued) Key to Terms: Information provided on drawings reflects a summary of the pertinent information required for the truss design. Detailed information on load cases, reactions, member lengths, forces and members requiring permanent lateral support may be found in calculation sheets available upon written request. BCDL = Bottom Chord standard design Dead Load in pounds per square foot. BCLL = Bottom Chord standard design Live Load in pounds per square foot. CL = Certified lumber. Des Ld = total of TCLL, TCDL, BCLL and BCDL Design Load in pounds per square foot. FRT = Fire Retardant Treated lumber. FRT-DB = D-Blaze Fire Retardant Treated lumber. FRT-DC = Dricon Fire Retardant Treated lumber. FRT-FP = FirePRO Fire Retardant Treated lumber. FRT-FL = FlamePRO Fire Retardant Treated lumber. FRT-FT = FlameTech Fire Retardant Treated lumber. FRT-PG = PYRO-GUARD Fire Retardant Treated lumber. g = green lumber. HORZ(LL) = maximum Horizontal panel point deflection due to Live Load, in inches. HORZ(TL) = maximum Horizontal panel point long term deflection in inches, due to Total Load, including creep adjustment. HPL = additional Horizontal Load added to a truss Piece in pounds per linear foot or pounds. Ic = Incised lumber. FJ = Finger Jointed lumber. L/# = user specified divisor for limiting span/deflection ratio for evaluation of actual L/defl value. L/defl = ratio of Length between bearings, in inches, divided by the vertical Deflection due to creep, in inches, at the referenced panel point. Reported as 999 if greater than or equal to 999. Loc = Location, starting location of left end of bearing or panel point (joint) location of deflection. Max BC CSI = Maximum bending and axial Combined Stress Index for Bottom Chords for of all load cases. Max TC CSI = Maximum bending and axial Combined Stress Index for Top Chords for of all load cases. Max Web CSI= Maximum bending and axial Combined Stress Index for Webs for of all load cases. NCBCLL = Non -Concurrent Bottom Chord design Live Load in pounds per square foot. PL = additional Load applied at a user specified angle on a truss Piece in pounds per linear foot or pounds. PLB = additional vertical load added to a Bottom chord Piece of a truss in pounds per linear foot or pounds PLT = additional vertical load added to a Top chord Piece of a truss in pounds per linear foot or pounds. PP = Panel Point. R = maximum downward design Reaction, in pounds, from all specified gravity load cases, at the indicated location (Loc). -R = maximum upward design Reaction, in pounds, from all specified gravity load cases, at the identified location (Loc). Rh = maximum horizontal design Reaction in either direction, in pounds, from all specified gravity load cases, at the indicated location (Loc). RL = maximum horizontal design Reaction in either direction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the indicated location (Loc). Rw = maximum downward design Reaction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the identified location (Loc). TCDL = Top Chord standard design Dead Load in pounds per square foot. TCLL = Top Chord standard design Live Load in pounds per square foot. U = maximum Upward design reaction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the indicated location (Loc). VERT(CL) = maximum Vertical panel point deflection in inches due to Live Load and Creep Component of Dead Load in inches. VERT(CTL) = maximum Vertical panel point deflection ratios due to Live Load and Creep Component of Dead Load, and maximum long term Vertical panel point deflection in inches due to Total load, including creep adjustment. VERT(LL) = maximum Vertical panel point deflection in inches due to Live Load. VERT(TL) = maximum Vertical panel point long term deflection in inches due to Total load, including creep adjustment. W = Width of non -hanger bearing, in inches. Refer to ASCE-7 for Wind and Seismic abbreviations. Uppercase Acronyms not explained above are as defined in TPI 1 Page 2 of 3 References: 1. AWC: American Wood Council; 222 Catoctin Circle SE, Suite 201; Leesburg, VA 20175; www.awc.org. 2. [CC: International Code Council; www.iccsafe.orQ. 3. Alpine, a division of ITW Building Components Group Inc.: 13723 Riverport Drive, Suite 200, Maryland Heights, MO 63043; www.alpineitw.com. 4. TPI: Truss Plate Institute, 2670 Crain Highway, Suite 203, Waldorf, MD 20601; www.tpinst.org. 5. SBCA: Wood Truss Council of America, 6300 Enterprise Lane, Madison, WI 53719; www.sbcindust[y.com. Page.3 of 3 Job Number: N333986 Ply: 1 SEQN: 7009 / T18 COMN Cust: R8975 JRef: 1WXIB9750051 ,7A5/320 ,167ED ,RG01 / 1672/ARIAMEAB ELEV.D Qty: 8 FROM: RWM DrwNo: 216.20.1201.24472 Truss Label: Al KD / YK 08/03/2020 6'1"7 12'8"15 19'4" 25'11"l 32'6"9 38'8" 6'1"7 + 67"8 ' 67"1 6,7"1 6774 6'1"7 1 10' -r 10� Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Des Ld: 37.00 NCBCLL: 10.00 Mean Height: 15.00 ft TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.87 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #1 Webs 2x4 SP #3 :W3, W4, W5 2x4 SP #2 N Lumber value set "l3B" uses design values approved 1/30/2013 by ALSC Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Loading Truss passed check for 20 psf additional bottom 9,4„ 19'4" Snow Criteria (.og,Pf in PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 6th.ed TPI Std: 2014 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE 5X5 E 38'8" 9,4" 28'8" Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.208 K 999 360 VERT(TL): 0.515 K 999 240 HORZ(LL): 0.076 J - - HORZ(TL): 0.132 J Creep Factor: 2.0 Max TC CSI: 0.532 Max BC CSI: 0.886 Max Web CSI: 0.490 VIEW Ver: 17.02.01A.1115.21 Q�A�A w'��'����� 4®� a No. 86367 • b STATE 4Fio 10�o'i'1 "i ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 1661 / 301 / 936 / - / 433 / 8.0 H 1662 / 301 / 936 / - / - / 8.0 Wind reactions based on MWFRS B Min Brg Width Req = 2.0 H Min Big Width Req = 2.0 Bearings B & H are a rigid surface. Bearings B & H require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - C 1442 - 3042 E - F 1073 -1962 C - D 1343 - 2764 F - G 1343 - 2765 D - E 1073 -1962 G - H 1442 - 3043 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - L 2659 -1146 K - J 2202 - 861 L - K 2202 - 835 J- H 2660 -1148 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. L - D 520 -199 K - F 471 - 725 D - K 471 - 724 F - J 521 -199 E-K 1318 -632 chord live load in areas with 42"-high x 24"-wide Ws- /C` 4 e QR`O I clearance. If �St 4 4�!j�n� 0 9 ®` Wind Wind loads based on MWFRS with additional C&C id�'�`S, 441mi k,°'+ member design. FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 **WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlingshipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigid ceilin Locations shown for ermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Applgy pfates to each face otPtruss and position as shown above and on the Join Details, unless noted otherwise. Defer to drawings 160A-Z for standard plate positions. ALPINE Alpine, a division of ITW Building Components Group Inc., shall not be responsible for any deviation from this drawing,any failure to build the ANmVCOMOANY truss In conformance with ANSI Q PI 1, or for handlin shlppin , installation and bracing of,trussesA seal on this drawing or cover page , , 2400 Lake Orange Dr. sting this drawing indicates acceptance of pro esstona engineering responsibility solely forthe design shown. The suitability 9 and use of this Q�awing for any structure is phe responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 150 For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.t inst.org; SBCA: www.sbcindust .com; ICC: www.iccsafe.org Orlando FL, 32837 Job Number: N333986 Ply: 1 SEQN: 7010 / T23 COMN Cust: R8975 JRef: 1WX189750051 ,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qty: 1 FROM: RDP DrwNo: 216.20.1156.58864 Truss Label: A1A TCE / WHK 08/03/2020 21'1"12 7'10"14 1�9"�z 12'1"12 17'10"4 �19� + 26'6"4 30'9"2 — 38'8" 7'10"14 4'2"14 - 1'5"12 5'4"8 + 4'2"14-� 7'1014 =5X5 F �1' F T11"5 5'8" I 40"11 + 7'11"5 +1'� 7'115 12' 18' 21' 26'8" 30'8"11 38'8" Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP. C Des Ld: 37.00 D Des d:: Mean Height: 15.00 ft .00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.87 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #1 :T2, T3 2x4 SP #2 N: Bot chord 2x4 SP #2 N Webs 2x4 SP #3 :W6, W9 2x4 SP #2 N: Lumber value set "1313" uses design values approved 1/30/2013 byALSC Plating Notes All plates are 2X4 except as noted. Wind Wind loads based on MWFRS with additional C&C member design. * The 3-0-0 section of lower Bottom Chord between panel points 0 and S may be field -removed as required provided that all remaining plate/wood contact areas stay intact and undisturbed. Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 6th ed TPI Std: 2014 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.201 E 999 360 VERT(TL): 0.549 E 999 240 HORZ(LL): 0.100 L - - HORZ(TL): 0.186 L Creep Factor: 2.0 Max TC CSI: 0.739 Max BC CSI: 0.793 Max Web CSI: 0.825 VIEW Ver: 17.02.01A.1115.21 ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 1518 / 301 / 936 / - / 433 / 8.0 J 1518 /301 /936 /- /- /8.0 Wind reactions based on MWFRS B Min Brg Width Req = 2.1 J Min Brg Width Req = 2.1 Bearings B & J are a rigid surface. Bearings B & J require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 1385 - 2665 F - G 1456 - 2370 C - D 1300 - 2278 G - H 1327 - 2399 D - E 1316 - 2355 H - 1 1299 - 2276 E - F 1434 - 2326 I - J 1386 - 2665 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - U 2299 -1067 M - L 2298 -1076 U - T 2297 -1066 L - J 2300 -1076 Afl��(�lt�' R-N 1841 -645 • • • ' /Bxp Maximum Web Forces Per Ply (Ibs) �G+ EN04 4r �� ��p— Webs Tens.Comp. Webs Tens. Comp. +•`.a • V •• o C-T No, 86367 R-F a � a, • • w STATE OF ��Her�(�A�►I►i®�, FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 305 - 446 F -N 1047 - 698 2100 -903 N - M 2114 -929 1050 -712 M -1 308 -451 "WARNING"' READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT'* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlingshipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperly attached rigid ceiling Locations shown for _permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face otruss and position as shown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Alpine, a division of ITW Buildino Components Group Inc. shall not be resoonsible for anv deviation from this drawing an failure to build the t seal on this drawiXg or cover page r for the design shown. The sui ability ANSI/TPI 1 Sec.2. ALPINE ANMCOMPANY 2400 Lake Orange Dr. Suite 150 Orlando FL, 32837 ,im i,ortorr acceptance any structure web sites: Job ,7A5 320 ,167 Db33RG01 / 1672/ARIA/4EAB ELEV.D City: 2 I FROM: RWM / T17 /SPEC Dr No: D216.20..11156..5898 Z7050051 Truss Label: A2 6'1"7 12'8"15 19' 25'11"1 NIB"' 38'8" 6'1"7 67'8 6'3"1 + 6'11"1 -� 6'7"8 -}- 6'1"7 5X5 E 10' 10' Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.87 ft Loc. from endwall: not in 9.00 ft GCp!: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bat chord 2x4 SP #1 Webs 2x4 SP #3 :W3, W4, W5 2x4 SP #2 N: Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 6th ed.201 TPI Std: 2014 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE 38'8" 18'8" 28'8" Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.208 K 999 360 VERT(TL): 0.515 K 999 240 HORZ(LL): 0.076 J - - HORZ(TL): 0.132 J Creep Factor: 2.0 Max TC CSI: 0.532 Max BC CSI: 0.886 Max Web CSI: 0.489 VIEW Ver: 17.02.01A.1115.21 'ow ttItfMfort r ,9 �0 �o No, 86367 o ®� STATE OF v 10, 1' 38'8"� ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 1661 / 298 / 934 / - / 427 / 8.0 H 1662 / 298 / 934 / - / - / 8.0 Wind reactions based on MWFRS B Min Brg Width Req = 2.0 H Min Brg Width Req = 2.0 Bearings B & H are a rigid surface. Bearings B & H require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - C 1422 - 3042 E - F 1052 -1962 C - D 1323 - 2764 F - G 1323 - 2765 D - E 1052 -1962 G - H 1423 - 3043 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - L 2659 -1128 K - J 2202 - 847 L - K 2202 - 818 J - H 2660 -1133 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. L - D 520 - 200 E - K 1317 - 635 D - K 477 -724 F - J 521 -200 K - F 476 -724 CORIV'r �4 L .,'�t741 ON(A� ,� FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 **WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT*` FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handling,shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building t Safety Information, by TPI an c7 SBCA) fsafey practices prior to performing these functions. Installers shall provide temporary BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathin and bottom chord shall have a propperly did ceiling Locations shown for ermanent lateral restraint of webs shall have bracin ins�alled per BCSI sections B3, B7 or B10 ile.- Apply plates to each face, oftrussand position as shown above and on the Join Details, unless noted otherwise. kefer to of i drawing for any str see this job's general notes from this drawing,an V, failure to build the % seal on this drawirSg or cover pa e, I for the Pde Sec shown. The suifabillty .org; SBCA: www.sbcindustry.com; ICC: www.iccsaf ALPINE ANnw COMPANY 2400 Lake Orange Dr. Suite 150 Orlando FL,32837 Job Number: N333986 ,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Truss Label: A3 Ply: 1 SEQN: 7012 / T16 / HIPS Cust: R8975 JRef: 1WXI89750051 Qly: 2 FROM: RWM DrwNo: 216.20.1166.59302 SSB / DF 08/03/2020 T10"14 7'10"14 10. 10. Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP. C Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.87 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N :T2, T4 2x4 SP 2400f-2.OE Bot chord 2x4 SP #1 :B2, B3 2x4 SP 2400f-2.0E: Webs 2x4 SP #2 N :W1, W6 2x4 SP #3: Lumber value set "l3B" uses design values approved 1/30/2013 by ALSC Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Loading Truss passed check for 20 psf additional bottom 17' 21'8" 30'9"2 9'1"2 4'8" 9'1"2 =5X5 =5X5 D E 9-4" 19'4" Snow Criteria (Pg,Pfin PSF) Pg: NA Ct: NA CAT: N< Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 6th ed TPI Std: 2014 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE 38'8" 9'4„ 28'8" Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.182 J 999 360 VERT(TL): 0.436 J 999 240 HORZ(LL): 0.0681 - - HORZ(TL): 0.116 1 Creep Factor: 2.0 Max TC CSI: 0.760 Max BC CSI: 0.836 Max Web CSI: 0.629 VIEW Ver: 17.02.01A.1115.21 a a No.86367 0. Q STATE OF 38'8" 7'10"14 10, 1' 38'8"+ ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 1714 / 308 / 940 / - / 385 / 8.0 G 1715 / 308 / 940 / - / - / 8.0 Wind reactions based on MWFRS B Min Brg Width Req = 2.0 G Min Brg Width Req = 2.0 Bearings B & G are a rigid surface. Bearings B & G require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - C 1481 - 3117 E - F 1509 - 2925 C - D 1509 - 2923 F - G 1481 - 3119 D - E 1157 - 2043 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - K 2715 -1174 J - 1 1978 - 720 K - J 1978 - 692 1 '- G 2717 -1204 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - K 404 -443 J - E 386 -244 K - D 834 -463 E - 1 837 -463 D - J 386 -244 1 - F 404 -443 chord live load in areas with 42"-high x 24"-wide rdo �' s Mv Ce �o'g clearance. 01W Wind A Wind loads based on MWFRS with additional C&C member design. FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 **WARNING`* READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) r safPety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathin and bottom chord shall have a propperly attached ri id ceiling Locations shown forfpermanent lateral restraint of webs shall have bracin insqalled per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face. o truss and position as shown above and on the Joint -Details, unless noted otherwise. Defer to drawings 16OA-Z for standard plate positions. Alpine, a division of truss in conformanc listing this drawinc and use of this i For more information see any structure is the re: ral notes page and these web his drawing,any failure to build the on this drawing or cover pa e ie design shown. The suitability TPI 1 Sec.2. CA: www.sbcindustry.com; ICC: www.iccsaf ALPINE Mn COMPANY 2400 Lake Orange Dr. Suite 150 Orlando FL, 32837 Job Number: N333986 Ply: 1 SEQN: 7013 / T15 / HIPS Cust: R8975 JRef: 1WX189750051 ,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EA8 ELEV.D Qty: 2 FROM: RWM DrwNo: 216.20.1156.58723 Truss Label: A4 KM / OF 08/03/2020 7'10"14 15' 23'8" 30'9"2 38'8" 1 7'10"14 + 7'1"2 8'8" i 70 2 7'10"14 i = 5X5 5X5 D T3 E 12 6 F�:;- 5 \55 X c� C W � W1 B G A H Mg 4X6(A2) =6X6 82 =6X6 83 =6X6=4X6(A2) 38'8" 10' 9'4" 9'4" 10, �1' 10' 19'4" 28'8" 38'8" Loading Criteria (psf) Wind Criteria Snow Criteria (.og,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in ]or Udefl U# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.194 J 999 360 B 1691 / 319 / 938 / - / 345 18.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.470 J 999 240 G 1692 / 319 / 938 / - / - / 8.0 BCDL: 10.00 Risk Category: 11 Snow Duration: NA HORZ(LL): 0.067 1 - - Wind reactions based on MWFRS Des Ld: 37.00 EXP: C Mean Height: 15.00 ft HORZ(TL): 0.115 I - - B Min Brg Width Req = 2.0 NCBCLL: 00 TCDL: 4.2 psf Code / Misc Criteria CreepFactor: 2.0 G Min Brg Width Req = 2.0 0. Soffit: 0.00 BCDL: 5.0 psf p Bearings B & G are a rigid surface. Bldg Code: FBC 6th ed.201 Max TIC CSI: 0.937 g g Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2014 Max BC CSI: 0.841 Bearings B & G require a seat plate. Spacing: 24.0 " C&C Dist a: 3.87 ft Rep Factors Used: Yes Max Web CSI: 0.582 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/l0(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 17.02.01A.1115.21 Lumber B - C 1496 -3045 E - F 1517 -2855 C - D 1517 - 2853 F - G 1496 - 3046 Value Set: 13B (Effective 6/1/2013) D - E 1236 -2198 Top chord 2x4 SP #2 N :T3 2x4 SP #1: Bot chord 2x4 SP #1 :132, B3 2x4 SP 2400f-2.OE: Maximum Bot Chord Forces Per Ply (Ibs) Webs 2x4 SP #2 N :W1, W6 2x4 SP #3: Chords Tens.Comp. Chords Tens. Comp. Lumber value set "13B" uses design values approved 1 /30/2013 by ALSC B - K 2643 -1183 J - 1 2082 - 848 K - J 2082 - 819 I - G 2645 -1213 Loading Truss passed check for 20 psf additional bottom Maximum Web Forces Per Ply (Ibs) t16I t �Pl chord live load in areas with 42"-high x 24"-wide owl Webs Tens.Comp. Webs Tens. Comp. clearance. AAr ►Yp4 Wind goof*4`�� ON K-D 709 -369 E-I 712 -369 Wind loads based on MWFRS with additional C&C member design. `* ida No. 86367 0 ® r o a � w ®!° Q STATE OF o % F ((���j1 ({�`.°� ``"r� •aaaaa FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety bracing per BCSI. Unless noted otherwise,top chord shall attached ri td ceiling Locations shown for _permanent lateral practices prior to performing these functions. Installers shall provide temporary have properly attached structural sheathing and bottom chord shall have a properly restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, _ as applicable. Apply plates to each face, otruss and position as shown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. ALPINE� Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the ANMCOMPAW truss in conformance with ANSI/TPI 1, or for handling, shlppinq, installation and bracing of,trussesA seal on this drawing or cover pa e , , 2400 Lake Orange Dr. listing this drawing indicates acceptance of protesslonarr engineering responsibility solely for the design shown. The suifabllity Suite Lake this drawing for is fhe the Building Desigrier ANSUTPI 1 Sec.2.150 and use of any structure responsibility of per For more information see this job's general notes page and these web sites: ALPINE: www.al ineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindust .com; ICC: www.iccsafe.crg Orlando FL, 32837 Job Number: N333986 Ply: 1 SEQN: 7014 / T14 / HIPS Cust: R8975 JRef: 1WX189750051 ,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qly: 2 FROM: RWM DrwNo: 216.20.1156.59067 Truss Label: A5 KM / DF 08/03/2020 13' 19'4" 31'10212 38'8"566'99"44 12 i i 4 219644 "1 5X5 1112X4 - 5 X 5 D E F 12 6 2X4 W C p2X4 o G u' to W 3 r` • B H -41 A I 4X6(A2) = 6X6 = 5X8 = 6X6=4X6(A2) 38'8" �1'+ 10, 9'4" 9'4" 10, + 10, 19'4" 28'8" + 38'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Sid: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.220 E 999 360 B 1665 / 699 / 931 / - / 304 / 8.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.543 E 999 240 H 1665 / 699 / 931 / - / - / 8.0 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.075 J - - Wind reactions based on MWFRS Des Ld: 37.00 EXP: C HORZ(TL): 0.130 J - - B Min Big Width Req = 2.0 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Code / Misc Criteria Creep Factor: 2.0 H Min Br Width Re 2.0 9 q = Soffit: 0.00 BCDL: 5.0 psf Bldg Code: FBC 6th ed.201 Max TC CSI: 0.505 Bearings B & H are rigid surface. Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.889 Bearings B & H require a seat plate. Spacing: 24.0 " C&C Dist a: 3.87 ft Rep Factors Used: Yes Max Web CSI: 0.355 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 17.02.01A.1115.21 Lumber B - C 1565 - 3029 E - F 1432 - 2498 C - D 1493 - 2774 F - G 1492 - 2775 Value Set: 13B (Effective 6/1/2013) D - E 1432 -2498 G - H 1564 -3031 Top chord 2x4 SP #2 N Bot chord 2x4 SP #1 Maximum Bot Chord Forces Per Ply (Ibs) Webs 2x4 SP #3 :W3, W5 2x4 SP #2 N: Chords Tens.Comp. Chords Tens. Comp. Lumber value set "13B" uses design values approved 1 /30/2013 by ALSC B - L 2641 -1259 K - J 2171 - 956 L - K 2171 - 926 J - H 2642 -1289 Loading Truss passed check for 20 psf additional bottom `� 11 (�� +`'�,,,��, Maximum Web Forces Per Ply (Ibs) liveload in areas with 42"-high x 24"-wide �y 1 A f A Webs Tens.Comp. Webs Tens. Comp. clew `,�i �ej�f'�►.Y.fjej�oIr, Wind �.J 'r L-D 572 -256 K-F 470 -224 D-K 470 F-J 573 ®4~ o•�`'< -224 -256 Wind loads based on MWFRS with additional C&C member design. o ^ to C 3 6 7 `t a 1 � 1 G7pV � ® e a c STATEWO a '1041P�0A'IA! ,c FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of Component Safety Information, TPI BCSI (Building by and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathingand bottom chord shall have a properly attached rigid ceiling Locations shown for _permanent lateral restraint of webs shall have bracinc� insalled per BCSI sections B3, B7 or B10, _ as applicable. Apply plates to each face oftrussand position as shown above and on the Joint9Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. ALPINE� Alpine, a division of ITW BuildinggComponents Group Inc.. shall not be responsible for any deviation from this drawing,apy failure truss in conformance with ANSI 1, or for handling, shlppinq, installation bracing this drawing to build the MN CO,� - and of,trussesA seal on or listing this drawing indicates acceptance of ro esslona engmeenn responsibility solely for the design shown. auilding cover pa�e .. 2400 Lake Orange Dr. The sui ability Suite 150 and use of this drawing for any structure is the responsibility of the Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.t inst.org: SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Orlando FL, 32837 Job Number: N333986 Ply: 1 SEQN: 7015 / T12 / HIPS Cust: R8975 JRef: 1WX189750051 ,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qty: 1 FROM: RWM DrwNo: 216.20.1157.00191 Truss Label: A6 IJB / WHK 08/03/2020 5'9"4 11' 19' 27'8" 32'10"12 38'8" 2„12 T 8 8,8„ 5'2„12 5'9„4 1 55 5X5 = 5X5 5X5 D E T3 F 12 6 � �2X4 W 2X4 C O G u) in W3 io � 1 B H �A I = L K —4X6(A2) = 5X5 = 5X8 J = 5X5 _= 4X6(A2) 38'8" �1'J 10, 9'4" 9'4" 10, 10' 19'4" 28'8" +1'� + 38'8" Loading Criteria (pso Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.203 E 999 360 B 1518 / 701 / 918 / - / 263 / 8.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.554 E 999 240 H 1518 / 701 / 918 / - /- / 8.0 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.064 J - - Wind reactions based on MWFRS Des Ld: 37.00 EXP: CMean Height: 15.00 ft HORZ(TL): 0.120 J - - B Min Brg Width Req = 1.8 NCBCLL: 10.00 Code / Misc Criteria Creep Factor: 2.0 TCDL: 4.2 psf H Min Brg Width Req = 1.8 Soffit: 0.00 BCDL: 5.0 sf Bldg Code: FBC sth ed.201 Max TC CSI: 0.774 p Bearings B & H are a rigid surface. g g Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.832 Bearings B & H require a seat plate. Spacing: 24.0 " C&C Dist a: 3.87 It Rep Factors Used: Yes Max Web CSI: 0.760 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 17.02.02A.1213.21 Lumber B - C 1616 -2720 E - F 1654 -2573 C - D 1496 - 2450 F - G 1498 - 2452 Value Set: 13B (Effective 6/1/2013) D - E 1677 -2603 G - H 1613 -2718 Top chord 2x4 SP #2 N :T3 2x4 SP #1: Bot chord 2x4 SP #1 Maximum Bot Chord Forces Per Ply (Ibs) Webs 2x4 SP #3 :W3, W5 2x4 SP #2 N: Chords Tens.Comp. Chords Tens. Comp. Lumber value set "1313" uses design values approved 1 /30/2013 by ALSC B - L 2374 -1314 K - J 2081 -1082 L - K 2074 -1047 J - H 2371 -1341 Wind Wind loads based on MWFRS with additional C&C 11�11'11�!��� member design. r�►/raj Maximum Web Forces Per Ply (Ibs) 1riY 1 rY Webs Tens.Comp. Webs Tens. Comp. �1e�rg�g0 i `\\\ ! \�+� • • 0 Irr 500. �j+ L - D 462 -161 K - F 591 - 359 D - K - 394 F - J 461 156 +••®+ ��P+ N��tw t V � � E - K 388 388 - 496 a,`, o No. 86367 y dillQ a� STATE OF e � roe /aNA��� �11i1d110111 FL REG# 278, Yoonhwak Kim, FL PE 486367 08/03/2020 '•WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "'IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and'SBCA) for safety to these functions. Installers temporary practices prior performing shall provide bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigid cellinp Locations shown for -permanent lateral restraint of webs shall have bracingInstalled per BCSI sections B3, B7 or 610. a as applicable. Apply plates to each face o truss and position as shown above and on the JoinDetails, unless noted otherwise. drawings 160A-Z for standard plate positions. f7efer to ALPINE ^', �LPPII 1 vN Alpine, a division of ITW Buildingq�Components Group Inr- shall not be responsible for any deviation from this drawing,any failure to build the ANMCOMPAW truss in conformance with ANSI/TPI 1, or for handlin4 s ipping, Installation and bracing of,trussesA seal on this drawing or cover listing this drawing indicates acceptance of pro7esslonar engineering responsibility solely for the design shown. and use of this rawing for any structure is he the Designer 1 Sec.2. page, , 2400 Lake Orange Dr. The suifabillty g Suite 150 responsibility of uilding per _ANSIIfPI For more information see this job'sww . general notes page these web sites: ALPINE: www.alpineitw.com; TPI: w.t inst.or ; SBCA: www.sbcindus .com; ICC: www.icrsafe.org Orlando FL, 32837 SEQN: 3855 / HIPS Ply: 1 Job Number: N333986 Cust: R 8975 JRef:1 WX189750051 T9 / FROM: RWM City: 1 7A5/320 ,167ED ,RG01 / 1672/ARIAI4EAB ELEV.D DrwNo: 216.20.1157.04090 Truss Label: A7 / YK 08/03/2020 9, 2 29'8" 38'8" 9' 8' 4'8" 8' 9' ,6X6 =5X5 =4X4 6X6 C T2 D E T3 F 12 6 T o (a) W (a) W5 in B G A H 4'a =4X6(A2) =6X6 =5X5 =6X6=4X6(A2) 1 38'8" 1' 10' 9.4" 9'4" 10, 1' 10� + 19'4" I` 28,8" 38'8" Loading Criteria (pso Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.229 J 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.427 J 999 240 B 1518 /- /- /900 f703 /222 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.075 1 - - G 1518 /- /- . /900 /703 !- EXP: C Kzt: NA HORZ(TL): 0.140 1 Wind reactions based on MWFRS Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Code / Misc Criteria Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.8 Soffit: 0.00 BCDL: 5.0 sf Bldg Code: FBC 6th ed.201 Max TC CSI: 0.906 G Brg Width = 8.0 Min Req = 1.8 p Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.854 Bearings B & G are a rigid surface. Bearings B & li require a seat plate. Spacing: 24.0 " C&C Dist a: 3.87 ft Rep Fac: Yes Max Web CSI: 0.280 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 18.02.01A.0205.19 Lumber B - C 1545 -2622 E - F 1557 -2395 C - D 1558 - 2395 F - G 1545 - 2621 Value Set: 13B (Effective 6/1/2013) D - E 1915 -3079 Top chord 2x4 SP #1 :T2, T3 2x4 SP #2 N: Bot chord 2x4 SP #1 Maximum Bot Chord Forces Per Ply (Ibs) Webs 2x4 SP #3 :W2, W5 2x4 SP #2 N: Chords Tens.Comp. Chords Tens. Comp. Lumber value set "'I 3B" uses design values approved 1 /30/2013 by ALSC B - K 2256 -1202 J - 1 3036 -1647 K - J 3034 -1648 I - G 2256 -1231 Bracing (a) 1X4 #3SRB or better continuous lateral restraint �11�1�1 Maximum Web Forces Per Ply (Ibs) to be Attach 8d Box Gun r�I/ equally spaced. with (2) or �tt� Webs Tens.Comp. Webs Tens. Comp. Restraint to beWqk nails(o.113"x2.5",min.). material ,� supplied and attached at both ends to a suitable �1� • • • �/ C - K 687 -289 E - I 485 765 support by erection contractor. t♦ •1�r Ar h • r0, K - D 483 -763 I - F 688 -290 4e'�+�® (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) a` • R N0.86367 scabs for (2) CLR'S where shown. Scab s reinforcement to be same size, species, grade, and a 80% length of web Attach 0.128x3" ® • member. with gun 01 ®. �. nails @ 6" oc. .. ° • i "Li •z z Wind +� ® STATE 4F • �,� Wind loads based on MWFRS with additional C&C ��� •°: member design. ®� • Additional Notes ®� t�Si a��'yy ,/�,�`+d>1611111 pq'e' Refer to General Notes for additional information FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI fo'r and SBCA) safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached ri id ceilin Locations shown forpermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or 810, s as applicable. Apply plates to each face, oftrussand position as shown above and on the Joinf Details, unless noted otherwise. Refer to ALPINE� drawings 160A-Z for standard plate positions. Q Alpine, a division of ITW Building Components Group Inc.. shall not be responsible for any deviation from this drawing,apy failure to build the ANR CCMVAW in truss conformance with ANSI e .. 6750 Forum Drive PI 1, or for handlin4, shipping, installation and bracing of,trussesA seal on this drawing or cover paability listing this drawing, indicates acceptance of pro essiona engineering responsibility solely for the design shown. The sui ability and of this d�awing for is the the Designer ANSI/TPI 1 Sec.2. Suite 305 use any structure responsibility of Building per For more information see this job's general notes page and these web sites: ALPINE: www.al ineitw.com; TPI: www.t inst.org: SBCA: www.sbcindus .com; ICC: www.iccsafe.org Orlando FL, 32821 Job Number: N333986 Ply: 1 SEQN: 7017 / T25 / HIPS Cust: R8975 JRef: 1WX189750051 ,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qly: 1 FROM: HMT DrwNo: 216.20.1157.00299 Truss Label: A10G JB / WHK 08/03/2020 7' 17' 26'4" 31'8" 38'8" 7' 10, 9'4" 5'4" 7' 1116X8 12 C =8X10 =H1014 T2 D T3 E 6X6 T4 F T 6� T_ b W (a) rn (a) B A fo G v H =4X6(A2) 81 III2X4 =5X5 1112X4 =6X8 III5X5J =5X5=3X6(A1) 1 26'4" 12'4" 4'10"4 5' 5'8" 3'8" 5'0"8 7'3"8 1'� 7'1"12 12' 17' 22'8" 26'4" 31'4"8 38'8" Loading Criteria (psf) Wind Criteria Snow Criteria (.og,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.147 M 999 360 B 1751 / 806 / - / - / - / 8.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.409 M 999 240 J 4100 / 1843 / - / - / - 18.0 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.053 K - - G 256 / 134 / - / - / - / 8.0 Des Ld: 37.00 EXP: Ceight: HORZ(TL): 0.101 K - - Wind reactions based on MWFRS Mean H 15.00 ft NCBCLL: 0.00 TCDL: Height: 4.2 psf Code / Misc Criteria Creep Factor: 2.0 B Min Brg Width Req = 2.1 Soffit: 0.00 BCDL: psf Bldg Code: FBC 6th ed.201 Max TC CSI: 0.896 J Min Brg Width Req = 5.7 Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.984 B Min Brg Width Req = 1.5 Bearings B, J. & G are a rigid surface. Spacing: 24.0 " C&C Dist a: 3.87 It Rep Factors Used: No Max Web CSI: 0.870 Bearings B, J. & G require a seat plate. Loc. from endwall: NA FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): Members not listed have forces less than 375# Wind Duration: 1.60 WAVE, HS VIEW Ver: 17.02.02A.1213.21 Maximum Top Chord Forces Per Ply (Ibs) Lumber Chords Tens.Comp. Chords Tens. Comp. Value Set: 13B (Effective 6/1/2013) B - C 1493 -3260 C - D 1247 -3005 Top chord 2x4 SP #2 N :T2, T3 2x6 SP SS: :T4 2x6 SP #2 N: Maximum Bot Chord Forces Per Ply (Ibs) Bot chord 2x4 SP #2 N :B1 2x4 SP #1: Webs 2x4 SP #3 :W6 2x4 SP #2 N: Chords Tens.Comp. Chords Tens. Comp. Lumber value set "13B" uses design values B - N 2859 -1288 L - K 2810 -1334 approved 1 /30/2013 by ALSC N - M 2884 -1292 K - J 791 -1817 M-L 2810 -1334 J-1 791 -1817 Bracing or n ter continuous lateral restraint��y����fI11E���� tobe((2) 8dmateriBox r Gun Yl A ,r�/j�P Maximum Web Forces Per Ply (Ibs) Webs (equalll 2B5 mi).tta Restraint al to O Tens.Comp.Webs Tens. Comp. supplied and attached at both ends to a suitable `��y����N� 4J410 '� a IV �a� C N 617 E J 1938 a� 0 - -100 - - 3930 support by erection contractor. ,.\CE 4 a ;�a D - K 1588 -3143 E - 1 2067 -872 (a) or scab reinforcement may be used in lieu of CLR p No.�36367 K - E 2681 -1062 I - F 372 -487 restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab .°m ea + ® reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128xY gun nails @ 6" oc. -�b STATE ®F,—�®T Q Loading ��mgrt� •. �`� pg°j #1 hip supports 7-0-0 jacks with no webs. o�P . +f Wind j A' nR�Qai®�®� IVl1� Wind loads and reactions based on MWFRS. 10114dd9d1►ttt� FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, TPI by and SBCA) for safety practices prior to performing these functions. Installers shall provide bracing per BCSI Unless noted otherwise,top chord shall have properly attached structural sheathin and bottom chord shall attached ri id ceiling Locations shown fornermanent lateral restraint of webs shall have bracin Insalled per BCSI sections temporary have a properly 63, B7 or B10, as sap I,Apply plates to each face. of truss and position as shown above and on the Join Details, unless noted otherwise. f7efer to drawings 160A-Z for standard plate positions. ALPINE Alpine, a division of ITW BuildinQComponents Group Inc. truss in ANSI shall not be responsible for any deviation from this drawing,any failure to build the MMCOWAW conformance with 1, or for handling, shippin , installation and bracing of,trussesA seal on this drawing or listing this drawing indicates acceptance of ro) esslonal engineering responsibility solely for the design shown. this gnawing for is cover pa e , , 240o Lake Orange Dr. The suifabllity 9 Suite 150 and use of any structure the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.al ineitw.com; TPI: www.t inst.org; SBCA: www.sbcindust .com; IM www.iccsafe.org Orlando FL, 32837 SEQN: 3853/ SPEC Ply: 1 Job Number: N333966 Cust: R8975 JRef:1WX189750051 T11 / FROM: RWM Qty: 1 7A51320 ,167ED ,RG01 /,1672/ARIA/4EAB ELEV.D DrwNo: 216.20.1157.04168 Truss Label: AS / YK 08/03/2020 7'1014 13'10" 21'4" 26 ' 32'6"2 38'8" 7'10"14 5'11"2 2'10"+ 4'S" r 64" 410"2 "i� 6'1„14 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h Spacing: 24.0 " C&C Dist a: 3.87 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #1 Webs 2x4 SP #3 :W3, W6 2x4 SP #2 N: Lumber value set "136" uses design values approved 1/30/2013 byALSC Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information 5X5 D 38'8" 9'4" 9'4" 10, 1' 19,4" 28'8" 'f 38,8" 'i- Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): 0.220 L 999 360 Lu: NA Cs: NA VERT(CL): 0.410 L 999 240 Snow Duration: NA HORZ(LL): 0.068 K - - HORZ(TL): 0.127 K Code / Misc Criteria Creep Factor: 2.0 Bldg Code: FBC 6th ed.201 Max TC CSI: 0.881 TPI Std: 2014 Max BC CSI: 0.859 Rep Fac: No Max Web CSI: 0.647 FT/RT:20(0)/l 0(0) Plate Type(s): VIEW Ver: 18.02.01A.0205.19 WAVE A a •�'��v 'YS� a 'i • Na, 86367 n • + � s • �o 0 -*w a STATE OF ®w � ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 1515 /- /- /921 1695 /321 1 1518 /- /- /916 /698 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.8 1 Brg Width = 8.0 Min Req = 1.8 Bearings B & I are a rigid surface. Bearings B & I require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 1585 - 2648 F - G 1366 -1995 C - D 1601 - 2456 G - H 1527 - 2444 D - E 1064 -1492 H -1 1629 - 2706 E - F 1655 - 2513 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - M 2290 -1231 L - K 2498 -1346 M - L 2446 -1305 K - I 2358 -1351 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. M - D 1664 -1070 F - K 431 - 632 M-E 1019 -1466 G-K 768 -424 s'v'�jC+°a10-4 aOR1aP �ONAfl 4c FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 "*WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlingshipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a proL�erly attached rigid ceilin Locations shown for _permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or 610, as applicable. Applgy plates to each face otruss and position as shown above and on the Join Details, unless noted otherwise. Defer to drawings 160A-Z for standard plate positions. Alpine, a division of ITW Buildino Components Group Inc. shall not be responsible for anv deviation from this drawing any failure to build the 1 seal on this drawing or cover page r for the design shown. The suif9ability ANSI/TPI 1 Sec.2. ALPINE M RW CQWAW 6750 Forum Drive Suite 305 Orlando FL, 32821 - l NI 1; or for handling, shipping, lost acceptance of pro essiona eng any structure is fhe responsibility ral notes page and these web sites: ALPINE: Job Number: N333986 Ply: 1 SEQN: 7019 / T21 / SPEC Cust: R8975 JRef: 1WX189750051 ,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D City: 1 FROM: RWM DrwNo: 216.20.1157.00642 Truss Label: A9 JB / WHK 08/03/2020 7'10"14 13'10" 18'8" 24'8" 29'V. 38'8" 7'1014 5'11"2 4'10" 6' 5' 9' 6X6 D 12 =6X6 =4X4 =5X5 6 C5 E F G h (a) T W3 "' °° T5 o r v B H A 43 I = 4X6(A2) = 5X5 = SX8 =— 6X6 = 3X6(A 1) 38'8" 10' 9'4" 9'4" 10, 11� 10' 19'4" 28'8" 38'8" Loading Criteria. (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.292 E 999 360 B 1514 / 694 / 909 / - / 321 / 8.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.797 E 846 240 H 1516 / 697 / 903 / - / - / 8.0 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.073 D - - Wind reactions based on MWFRS Des Ld: 37.00 EXP: C HORZ(TL): 0.137 D - - B Min Brg Width Req = 1.8 Mean Height: 15.00 ft NCBCLL: 10.00 Code / Misc Criteria Creep Factor: 2.0 H Min Brg Width Req = 1.8 TCDL: 4.2 psf B & H are a rigid Bearings Soffit: 0.00 BCDL: 5.0 psf Bldg Code: FBC 6th ed.201 Max TC CSI: 0.879 9 surface. Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.905 Bearings B & H require a seat plate. Spacing: 24.0 " C&C Dist a: 3.87 ft Rep Factors Used: Yes Max Web CSI: 0.845 Members not listed have forces less than 375# 0 FT/RT:20 /10 0 Loc. from endwall: not in 9.00 ft () () Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0,18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 17.02.02A.1213.21 Lumber B - C 1600 -2648 E - F 2002 -3069 C - D 1620 - 2461 F - G 1581 - 2379 Value Set: 13B (Effective 6/1/2013) D - E 2555 -3805 G - H 1563 -2600 Top chord 2x4 SP #2 N :T5 2x4 SP 2400f-2.OE: Bot chord 2x4 SP #1 Maximum Bot Chord Forces Per Ply (Ibs) Webs 2x4 SP #3 :W3 2x4 SP #2 N: Chords Tens.Comp. Chords Tens. Comp. Lumber value set "1313" uses design values approved 1 /30/2013 by ALSC B - L 2290 -1231 K - J 2821 -1584 L - K 1836 - 912 J - H 2232 -1244 Bracing (a) 1X4 #3SRB or better continuous lateral restraint �i11tf ! If !l rMaximum Web Forces Per Ply (Ibs) to spaced. Attach with(2)8d Box or Gun ol�f� (me Webs Tens.Comp. Webs Tens. Comp. HWA naibls(0113Ix2 Re t material to be��,+�Ow, 1` i both 9 Ir Q supplied and attached at ends to a suitable ®`� ,0 a P. L - D 598 -345 F - J 467 -665 support by erection contractor. jYr �1� C. D - K 2451 -1647 J - G 727 376 (a) or scab reinforcement may be used in lieu of CLR a� 9 0 E - K 1411 -1982 7 restraint. substitute (1) scab for (1) CLR and (2) ` o N�. �6 6/ g scabs for (2) CLR'S where shown. Scab �. m reinforcement to be same size, species, grade, and m 09 • 80% length of web member. Attach with 0.128x3" gun i e "� � a X nails @ 6" oc. a p iy ~ STATE QE ® v Wind pm��� S® r W,, F -�s1 Wind loads based on MWFRS with additional C&C s r� �� member design. ��� + A g ®�V✓�i t� evv0 ® C FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, � by TPI an SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per SCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per SCSI sections 63, 67 or 910 as applicabgle. Apply Oates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to'ALPINE drawings 160A-Z for standard plate positions. Alpine, a division of ITW Build!ng Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the AN RW COMVANY truss in ANSI conformance with 1, or for handli4 shippin , installation and bracing of,trussesA seal on this drawing or cover pa e • , 2400 Lake Orange Dr. listing this drawing indicates acceptance of ro) essronalq engineering responsibility solely for the design shown. The suit9abllity 9 and use of this drawing, for any structure is the the Building Designer ANSI/TPI Suite 150 responsibility of per 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.al ineitw.com; TPI: www.t inst.org; SBCA: www.sbcindust .com; ]CC: www.iccsafe.org Orlando FL, 32837 SEQN: 3838 / SPEC Ply: 1 Job Number: N333986 Cust: R 8975 JRef:1 WXI89750051 T4 I FROM: HMT Qty: 1 , A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D DrwNo: 216.20.1157.03981 Truss Label: A11G TCE / YK 08/03/2020 co Tl0"14 T10"14 13'10" 20'8" 5' 11 "2 6' 10" 5X5 D 26' 31'8" 38'8" 5'4" 5'8" 7' 12 6 F�- ,5X5=5X10(SRS) =4X10 5X5 C E F T4 G Tn o_ B H A 3X6(A1) 1112X4 =5X10 1112X4 L 1114X4K =4X6=3X6(A1) =5X5 21' j 5' 7'11"5 6'0"11 69"12 3'10"4 'TI§ 5'4"8 7'11"5 14' 20'9"12 24'8, 26' 31'4"8 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.87 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N :T4 2x4 SP #1: Bot chord 2x4 SP #2 N Webs 2x4 SP #3 Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 56 plf at -1.00 to 56 plf at 27.73 TC: From 28 plf at 27.73 to 28 plf at 31.67 TC: From 56 plf at 31.67 to 56 plf at 39.67 BC: From 20 plf at 0.00 to 20 plf at 27.73 BC: From 10 plf at 27.73 to 10 plf at 31.64 BC: From 20 plf at 31.64 to 20 plf at 38.67 TC: 174 lb Conc. Load at 27.73 TC: 161 lb Conc. Load at 29.60 TC: 87 lb Conc. Load at 31.60 TC: 288 lb Conc. Load at 31.64 BC: 128 lb Conc. Load at 27.73 BC: 125 lb Conc. Load at 29.60 BC: 489 lb Conc. Load at 31.64 Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): 0.031 G 999 360 Lu: NA Cs: NA VERT(CL): 0.059 G 999 240 Snow Duration: NA HORZ(LL): 0.013 0 - - HORZ(TL): 0.024 0 Code ! Misc Criteria Creep Factor: 2.0 Bldg Code: FBC 6th ed.201 Max TC CSI: 0.753 TPI Std: 2014 Max BC CSI: 0.886 Rep Fac: Varies by Ld Case Max Web CSI: 0.669 FT/RT:20(0)/10(0) Plate Type(s): WAVE VIEW Ver: 18.02.01A.0205.19 `ti111t11111P►t//pI ®,�d,+� ®B �r' � Jet � � �1'�►�''�i0 No. 86367 m y m a r a @� STATE OF 12'8" 7'3"8 1' 38'8"i ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 782 /- /- /- /385 /- M 1016 /- /- /- /462 /- K 1680 /- !- /- [795 A H 903 /- A /- /433 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 M Brg Width = 8.0 Min Req = 1.5 K Brg Width = 8.0 Min Req = 2.3 H Brg Width = 8.0 Min Req = 1.5 Bearings B, M. K, & H are a rigid surface. Bearings B, M, K, & H require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 537 -1085 E - F 389 -166 C - D 279 - 542 F - G 509 -1166 D - E 285 - 546 G - H 664 -1396 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - O 894 -414 J - H 1184 - 539 O-N 890 -415 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - N 271 - 582 F - K 768 -1368 N - E 813 - 367 F - J 1757 - 789 E - M 518 - 875 J - G 377 - 244 Wind®10Rta�e Wind loads and reactions based on MWFRS. ®ems °�1f�1M� Q ® ! Additional Notes ���td;/Ql�A1 ImeN Refer to General Notes for additional information FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Alpine, a division of ITV trfiss in conformance w listing this drawing, in and use of this drav For more information see this npp Gomponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the ilrfPI 1, or for handlinT shipping, installation and bracing oftrussesA seal on this drawing or cover pa gqe s acceptance of pro esslonar engineering responsibility solely for the design shown. The sul ability r any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. feral notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA:. www.sbcindustry.com; ICC: www.iccsaf ALPINE ANMCOMPAW 6750 Forum Drive Suite 305 Orlando FL, 32821 Job Number: N333986 ,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Truss Label: B1 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " 7'10"14 7'10"14 7'11"5 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 611/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Webs 2x4 SP #3 Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C member design. Ply: 1 ---- Qty: 3 1 2 5'1" 1 2 +_ '1 =4X4 D 21' 6'0"11 i-4 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 6th ed.20 TPI Std: 2014 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE SEQN:7021 / T29 /COMN Cust:R8975 JRef:1WX189750051 FROM: RWM DrwNo: 216.20.1156.59987 JB / WHK 08/03/2020 20'10"4 7'0"4 T 21' Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.034 J 999 360 VERT(TL): 0.095 J 999 240 HORZ(LL): 0.013 J - - HORZ(TL): 0.024 J Creep Factor: 2.0 Max TC .CSI: 0.664 Max BC CSI: 0.664 Max Web CSI: 0.557 26'4" ro 1 T T 1 5a" 5.4" 26'4" A,Maximum Reactions (Ibs) Loc R / U / Rw / Rh / RL / W B 845 / 189 / 553 / - / 274 / 8.0 H 1051 / 193 / 550 / - 1- / 8.0 K 185 /54 /116 /- /- /8.0 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 H Min Brg Width Req = 1.5 K Min Brg Width Req = 1.5 Bearings B, H, & K are a rigid surface. Bearings B, H, & K require a seat plate. Members not listed have forces less than 375# VIEW Ver: 17.02.02A.1213.21 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. ,911111lf!►f��+�i�� �GENS AA a N0. 86367 P ° STATE OF B - C 643 -1221 D - E 482 - 694 C - D 483 -679 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-J 1015 -501 J - 1 1011 -501 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - 1 394 - 579 E - H 517 - 903 I- E 586 -167 or 0 �OTSIV'Ae' o`er NAU FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handling,shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building t Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperly id ceilin Locations shown for ermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, 87 or B10 e. App7y plates to each face oftrussand position as shown above and on the Join Details, unless noted otherwise. kefer to 60A-Z for standard plate positions. acceptance or rc any s ructure is the from this drawing,an failure to build the 1 seal on this draw!Xg or cover pa e r for the design shown. The suitability ANSI/TPI 1 Sec.2. ALPINE ANm COMPAW 2400 Lake Orange Dr. Suite 150 Orlando FL, 32837 more information see this ICU: Job Number: N333986 I Ply: 1 SEQN: 7022 / T27 / GABL Cust: R8975 JRef: 1WXI89750051 ,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qiy: 1 FROM: RWM DrwNo: 216.20.1157.00393 Truss Label: B2GE _ — JB / WHK 08/03/2020 6'1'7 13'10" 27'8" , 6'147 7'8"9 13'10" F-- 310 i 4- 1 2' -- { i' 44 H Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Webs 2x4 SP #3 Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Plating Notes All plates are 2X4 except as noted. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes See DWGS Al6015ENC101014 & GBLLETIN1014 for gable wind bracing and other requirements. Truss designed to support 8" maximum gable end overhang. Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 6th ed.201 TPI Std: 2014 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.021 0 999 360 VERT(TL): 0.064 0 999 240 HORZ(LL): -0.011 M - - HORZ(TL): 0,020 M Creep Factor: 2.0 Max TC CSI: 0.146 Max BC CSI: 0.284 Max Web CSI: 0.127 VIEW Ver: 17.02.02A.1213.21 ♦ Maximum Reactions (Ibs), or.=PLF Loc R / U / Rw / Rh / RL / W B 209 / 77 / 110 1- / 290 / 8.0 B' 79 /17 /42 /- /- /248 Z 256 /95 /210 /- /- /8.0 AA57 /21 /55 /- /- /16.0 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 B Min Brg Width Req = - Z Min Brg Width Req = 1.5 AA Min Brg Width Req = 1.5 Bearings B, B, Z, & Z are a rigid surface. Bearings B, B. Z. & Z require a seat plate. Members not listed have forces less than 375# `�ftffiflll►1�;� H WAS J5 41 No, 86867 .i -A �• STATE OFc ®4/� I'1Vs'ONAj FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS of in pp�Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the ilrfPI 1, or for handlinct, shipping, mstallatidn and bracing of,trussesA seal on this drawing or cover pa e, s acceptance of pro) essionaf engineering responsibility solely for the design shown. The suif9abflity ,r any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. neral notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsaf ALPINE A-COWAW 2400 Lake Orange Dr. Suite 150 Odando FL, 32837 Job Number: N333986 Ply: 1 SEQN: 7030 / T28 / GABL Cust: R8975 JRef: 1WX189750051 ,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qty: 1 FROM: RWM DrwNo: 216.20.1156.59613 Truss Label: C1GE JB / WHK 08/03/2020 2'2" + 4'2" 6'2" 1 8'4" 2'2" 2' 2' 2'2" =4X4 D T 12 6 C E M N B F Fl 4"3 ALi Li Li J + H 2X4(A1)=2X4(A1) Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Des Ld: 37.00 Mean Height: 15.00 It NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Webs 2x4 SP #3 Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Plating Notes All plates are 2X4 except as noted. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes See DWGS A16015ENC101014 & GBLLETIN1014 for gable wind bracing and other requirements. + MEMBER TO BE LATERALLY BRACED FOR HORIZONTAL WIND LOADS. BRACING SYSTEM TO BE DESIGNED AND FURNISHED BY OTHERS. 8'4" 2'2" 2' 2' 2'2„ 2-2„ 1 4,2„ 1 67' 1 84 Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): 0.003 1 999 360 Lu: NA Cs: NA VERT(TL): 0.008 1 999 240 Snow Duration: NA HORZ(LL): 0.001 H - - HORZ(TL): 0.003 H Code / Misc Criteria Creep Factor: 2.0 Bldg Code: FBC 6th ed.201 Max TC CSI: 0.223 TPI Std: 2014 Max BC CSI: 0.095 Rep Factors Used: Yes Max Web CSI: 0.086 FT/RT:20(0)/10(0) Plate Type(s): VIEW Ver: 17.02.01A.1115.21 WAVE ♦ Maximum Reactions (Ibs), or'=PLF Loc R / U / Rw / Rh / RL / W B` 185 / 87 / 135 / - / 59 / 24.0 F' 185 /87 /135 /- /- /24.0 Wind reactions based on MWFRS B Min Brg Width Req = - F Min Brg Width Req = - Bearings B & H are a rigid surface. Bearings B & H require a seat plate. Members not listed have forces less than 375# *,11111A WA 1lf 1ii►/'��Pr bogas of P a No.86367 r v� a� STATE 4Eft <!,j '� S •OR IV "ea o� ON+AI !� e FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safPety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted dtherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigpid ceiling Locations shown fortpermanent lateral restraint of webs shall havebracing installed per BCSI sections B3, B7 or B10, as appllcab�le. Apply plates to each face o truss and position as shown above and on te Joint Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Alpine, a division of ITW BuildinhcL Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the AN rv+co�anNv truss in conformance with ANSI/TPI 1, or for handl!ncl, shipping, installation and bracing of,trussesA seal on this drawing or cover pa e , . 240o Lake Orange Dr. listing this drawing indicates acceptance of pro) esslonaf engineering responsibility solely for the design shown. The suit9abdlty g and use of this yawing for any structure is fhe responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 150 For more information see this job's general notes page and these web sites: ALPINE: www.al ineitw.com; TPI: www.l inst.org: SBCA: www.sbcindusl .com; ICC: www.iccsafe.org Orlando FL, 32837 SEON: 3845 / VAL Ply: 1 Job Number: N333986 Cust: R 8975 JRef:1VJX189750051 T7 I FROM: RWM city: 1 7A51320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D DrwNo: 216.20.1157.03965 Truss Label: V4 TCE / YK 08/0312020 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.59 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Refer to General Notes for additional information Valley truss connection to truss below shall be designed and furnished by others . 11118 i 3'11" 1'11 "8 1'11 "8 12 6 =4X4 B A4X4(D1)=4X4(D1) C 14'11"3 D 3'11" _i 3'11" 3'11" Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 6th ed.201 TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.004 999 360 VERT(CL): 0.007 999 240 HORZ(LL):-0.001 - - HORZ(TL): 0.003 Creep Factor: 2.0 Max TC CSI: 0.070 Max BC CSI: 0.104 Max Web CSI: 0.000 VIEW Ver: 18.02.01A.0205.19 t111111111PPP� �i wA,,� \0ENS�+/ A� No 86367 wp � 42 • v-,b ; STATE OF cv,� i 6 F * 0 Tor d+e ♦ Maximum Reactions (Ibs), or *=PLF Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL D* 75 /- !- /31 /10 /6 Wind reactions based on MWFRS D Brg Width = 47.0 Min Req = - Bearing A is a rigid surface. Members not listed have forces less than 375# wo— 6 4OR10�' •' °�"e® doliON A. g ee FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT*" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS sses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building nponent Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary sing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly ched rigid ceiling Locations shown forl�ermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or 810 applicable. Apply plates to each face of truss and position as shown above and on the Joint9Details, unless noted otherwise. kefer to' Nings 160A-Z for standard plate positions. of ITW Buildingq�Components Group Inc. shall not be responsible for any deviation from this drawing,anv failure to build the nce with ANSI/TPI 1, or for handlinn, shipping, installation and bracing of.trussesA seal on this drawirig or cover page. nc1 indicates acceptance of pro) essrona englneerin� responsibility solely for the design shown. The sui abrltty yawing for any structure is he responsibility of the uilding Designer per ANSI/TPI 1 Sec.2. see this job's general notes page and these web sites: ALPINE: www.aloineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsat AL NE ANR CCWAW 6750 Forum Drive Suite 305 Orlando FL, 32821 Job Number: N333986 Ply: 1 SEQN: 7031 / T5 / VAL Cust: R8975 JRef: 1WXI89750051 ,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qly: 1 FROM: RWM DrwNo: 216.20.1156.59659 Truss Label: MV01 JB / WHK 08/03/2020 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 15.00 it TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Webs 2x4 SP #3 Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C member design. Right,end vertical not exposed to wind pressure. Additional Notes Valley truss connection to truss below shall be designed and furnished by others . 17 4'1"11 4' 1 "11 4'1"11 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: Ni Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 6th ed.201 TPI Std: 2014 Rep Factors Used: Yes FT/RT:20(0)/l 0(0) Plate Type(s): WAVE 1112X4 B Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(TL): NA HORZ(LL): 0.003 C HORZ(TL): 0.006 C Creep Factor: 2.0 Max TC CSI: 0.222 Max,BC CSI: 0.177 Max Web CSI: 0.100 VIEW Ver: 17.02.02A.1213.21 ♦ Maximum Reactions (lbs), or.=PLF Loc R /U /Rw /Rh /RL /W D` 75 / 28 / 52 /- / 18 / 49.7 Wind reactions based on MWFRS D Min Brg Width Req = - Bearing A is a rigid surface. Members not listed have forces less than 375# `1e�N1If I11lI/1t� �1 � � • 7 a STATE OF "41"iVAL ��N d t l ll iki✓ J 14144� FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlingshipping, installingand bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI.. Unless noted otherwise,top chord shall have properly attached structural sheathin and bottom chord shall have a propperly attached r!ppid ceilln Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. App�y plates to each face, of truss and position as shown above and on the Joint9Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc, shall not be responsible for any deviation from this drawing,any failure to build the ANnW[OWANY truss in conformance with ANSI g Pl 1, or for handlin4, shippinq, installation and bracing of,trussesA seal on this drawing or cover paqe , , 240o Lake Orange Dr. listing this drawing indicates acceptance of pro esslona engineering responslbillty solely for the design shown. The suigabillty and use of this gnawing for any structure is fhe responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 150 For more information see this job's general notes page and these web sites: ALPINE: www.al ineitw.com; TPI: www.t inst.or ; SBCA: www.sbcindusf .com; ICC: www.iccsafe.org Orlando FL, 32837 Job Number: N333986 Ply: 1 SEQN: 7032 / T6 / VAL Cust: R8975 JRef: 1WX189750051 ,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qty: 1 FROM: RWM DrwNo: 216.20.1157.00408 Truss Label: MV02 JB / WHK 08/03/2020 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Webs 2x4 SP #3 Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Valley truss connection to truss below shall be designed and furnished by others . 12 6 1112X4B i 21"1,1 v 2'1"11 2'1 "11 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 6th ed.201 TPI Std: 2014 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE T N T Defl/CSI Criteria PP Deflection in loc Udefl L/# VERT(LL): NA VERT(TL): NA HORZ(LL): 0.000 C HORZ(TL): 0.001 C Creep Factor: 2.0 Max TC CSI: 0.039 Max BC CSI: 0.041 Max Web CSI: 0.026 VIEW Ver: 17.02.02A.1213.21 ♦ Maximum Reactions (lbs), or*=PLF Loc R /U /Rw /Rh /RL /W D* 75 / 13 / 48 /- / 10 / 25.7 Wind reactions based on MWFRS D Min Brg Width Req = - Bearing A is a rigid surface. Members not listed have forces less than 375# r, Ake- q N®, 86367 Or r e SATE 4F • CcJti a w rr S oao®e® e, FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly attache. ri id ceilin Locations shown for oermanent lateral restraint of webs shall have bracinginstalled per BCSI sections B3, B7 or B10, as applicable. Applgy Oates to each face o truss and position as shown above and on the JoinfDetails, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformance with ANSI PI 1, or for handling, shlppinp, installation and bracing of,trussesA seal on this drawing or cover page , 2400 Lake Orange Dr. listing this drawing indicates acceptance of pro) esslonar engineering responsibility solely for the design shown. The suitability g and use of this yawing for any structure is the responsibility of the uilding Designer per ANSI/TPI 1 Sec.2. Suite 150 For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com• TPI: www,tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Odando FL, 32837 Job Number: N333986 Ply: 1 SEQN: 7033 / T8 / EJAC ,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qty: 14 FROM: RWM Truss Label: EJ7 Cust:R8975 JRef: 1WXI89750051 DrwNo: 216.20.1156.59441 JB / WHK 08/03/2020 T + 7- 7- Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Lumber value set "l36" uses design values approved 1/30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. C Snow Criteria (Pg,Pfin PSF) Defl/CSI Criteria AMaximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in Icc L/defl L/# Loc R / U / Rw / Rh / RL / W B 331 / 117 / 259 / - / 173 / 8.0 Pf: NA Ce: NA VERT(LL): NA Lu: NA Cs: NA VERT(TL): NA D 127 / 20 / 101 / - / - / 1.5 Snow Duration: NA HORZ(LL): 0.017 D C 171 / 133 / 91 / - / - / 1.5 HORZ(TL): 0.031 D Creep Factor: 2.0 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 Code / Misc Criteria Bldg Code: FBC 6th ed.201 Max TC CSI: 0.713 D Min Brg Width Req = - TPI Std: 2014 Max BC CSI: 0.527 C Min Brg Width Req = - Rep Factors Used: Yes Max Web CSI: 0.000 Bearing B is a rigid surface. Bearing B requires a seat plate. FT/RT:20(0)/10(0) Plate Type(s): Members not listed have forces less than 375# VIEW Ver: 17.02.02A.1213.21 WAVE a AA - No. 86367 0 a .. ®A STATE OF1 Sioji �QNAL;, FL REG# 278, Yoonhwak Kim, FL PE 486367 08/03/2020 `"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted oytherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperly attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have brac!n installed per BCSI sections B3, B7 or B10 as applicabgle. Apply Oates to each face oftrussand position as shown above and on the Joint9Details, unless noted otherwise. f7efer to' drawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for anv deviation from this drawing an failure to build the k seal on this drawl vg or cover pa e, . I for the design shown. The sui ability ALPINE ANN CCWAW 2400 Lake Orange Dr. Suite 150 Orlando FL, 32837 ivi 1;ortor r acceptance any structure TPI: www.tpinst.org: SBCA: www.sbcindustry.com; ICC: Job Number: N333986 ,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Truss Label: EJ7A Ply: 1 SEQN:7034 / T3 / EJAC I Cust:R8975 JRef: 1WXI89750051 Qty: 2 FROM: RWM DrwNo: 216.20.1157.00143 JB / WHK 08/03/2020 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " T �— 2'4" Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Lumber value set "1313" uses design values approved 1/30/2013 byALSC Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. Snow Criteria (Pg,Pfin PSF) Pg: NA Ct: NA CAT: W Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 6th ed.201 TPI Std: 2014 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE 7' 7' Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(TL): NA HORZ(LL): 0.012 D HORZ(TL): 0.021 D Creep Factor: 2.0 Max TC CSI: 0.775 Max BC CSI: 0.504 Max Web CSI: 0.000 VIEW Ver: 17.02.02A.1213.21 C 1 ♦ Maximum Reactions (Ibs) Loc R / U / Rw / Rh / RL / W B 425 / 178 / 370 / - / 202 / 8.0 D 125 /12 /101 /- /- /1.5 C 161 /125 /78 /- /- /1.5 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 D Min Brg Width Req = - C Min Brg Width Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# ,��111`,1,Qf►iPlt*///t �q<10®NSA WA� rAo, ® rl No. 86367 v 0 Q STATE0OF o is IN /0NP,L ddli111110kr FL REG# 278, Yoonliwak Kim, FL PE #86367 08/03/2020 "'WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperly attached rigid ceiling Locations shown fortpermanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicab-le. Apply plates to each face o truss and position as shown above and on the Joint -Details, unless noted otherwise. Refer to A LPI N E drawings 160A-Z for standard plate positions. AW Alpine, a division of ITW BuildinlgComponents Group Inp. shall not be responsible for any deviation from this drawing,an� failure to build the ANmYCOEU truss in conformance with ANSI TPI 1, or for handling, shipping, installation and bracing of,trussesA seal on this draw! g or cover pa e , . 2400 Lake Orange Dr. listing this drawing, indicates acceptance of pro) essiona engineering responsibility solely for the design shown. The s i'Mability g and use of this drawing for any structure is the responsibility of the Building Desigrier per ANSI/TPI 1 Sec.2. Suite 150 For more information see this job's general notes page and these web sites: ALPINE: www.al ineitw.com; TPI: www.t inst.org; SBCA: www.sbcindust .com: ICC: www.iccsafe.org Orlando FL, 32837 Job Number: N333986 Ply: 1 SEQN: 7035 / T1 / EJAC Cust: R8975 JRef: 1WX189750051 ,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qty: 1 FROM: RWM DrwNo: 216.20.1157.00049 Truss Label: EJ7S KM / WHK 08/03/2020 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Sid: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Lumber value set 1313" uses design values approved 1/30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 6th ed. TPI Std: 2014 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE 7' 7' Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(TL): NA HORZ(LL): 0.018 C HORZ(TL): 0.033 C Creep Factor: 2.0 Max TC CSI: 0.725 Max BC CSI: 0.533 Max Web CSI: 0.000 VIEW Ver: 17.02.02A.1213.21 B 0 in ♦ Maximum Reactions (lbs) Loc R / U / Rw / Rh / RL / W A 270 / 79 / 188 1- / 151 / 8.0 C 128 /21 /104 /- /- /1.5 B 174 /135 /95 /- /- /1.5 Wind reactions based on MWFRS A Min Brg Width Req = 1.5 C Min Brg Width Req = - B Min Brg Width Req = - Bearing A is a rigid surface. Bearing A requires a seat plate. Members not listed have forces less than 375# will III Ilffffrpj E NSF No.86367 ® d p d W STATE OF ° 4� e FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSL Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly attachetl rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10. as applicable. Apply plates to each face of truss and position as shown above and on the Joinf9Details, unless noted otherwise. itefer to ALPINE drawings 160A-Z for standard plate positions. Alpine, a division of ITW Buildip,$Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the aNmvcoMvauv truss to conformance with ANSI 1, or for handlin] shipping, installation and bracing of,trussesA seal on this drawing or cover pa e , , 2400 Lake Orange Dr. listing this drawing indicates acceptance of pro) esslonar engineering responsibility solely for the design shown. The sui�abdlty g and use of thisrawing for any structure is fhe responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 150 =or more information see this job's general notes page and these web sites: ALPINE: www.aloineitw.com: TPI: www.toinst.oro: SBCA: www.sbcindustrv.com, [CC- www.iccsafe.ora Orlando FL, 32837 Job Number: N333986 Ply: 1 SEQN: 7023 / T2 / JACK Cust: R8975 JRef: 1WX119750011 ,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qty: 5 FROM: RDP DrwNo: 216.20.1156.59489 Truss Label: CJ5 KD / YK 08/03/2020 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " T Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 611/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 6th ed.201 TPI Std: 2014 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE 4' 11 "4 4' 11 "4 Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(TL): NA HORZ(LL): 0.005 D HORZ(TL): 0.010 D Creep Factor: 2.0 Max TC CSI: 0.411 Max BC CSI: 0.254 Max Web CSI: 0.000 VIEW Ver: 17.02.01A.1115.21 Ci M (V to M M ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 256 / 95 / 207 / - / 128 / 8.0 D 89 /13 /68 /- /- /1.5 C 118 /92 /61 /- /- /1.5 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 D Min Brg Width Req = - C Min Brg Width Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# ONE WAkArl No, 86367 m d 0 1 V S W STATE OFF® b FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in, fabricating, handling, shipping, installing and brac_ing.. Refer to and follow the latest edition of .",up l' w ccuui wwtwns NIUMI IUt etmanent iaterai restraint oTweos snan nave Dracin mstallea per bL;bI sections t53, bt or btu, applicab e. App y plates to each face o truss and position as shown above and on the Join Details, unless noted otherwise. kefer to swings 160A-Z for standard plate positions. line, a division of ITW Buildingq�Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3s in conformance with ANSI/TPI 1, or for handlia shipping, installation and bracing of,trussesA seal on this drawing or cover pa e , tng this drawing indicates acceptance of pro) engineering responsibility solely for the design shown. The s ifflablllty J use of this yawing for any structure is the responsibility of the uilding Designer per ANSI/TPI 1 Sec.2. more information see this lob's general notes page andthese web sites: ALPINE: www.alpineitw.com• TPI: www.tpinst.org• SBCA• www.sbcindust com• ICC• www iccsaf ALPINEI M" CCWAW 2400 Lake Orange Dr. Suite 150 Orlando FL, 32837 Job Number: N333986 Ply: 1 SEQN: 7028 / T32 / JACK Cusl: R 8975 JRef: 1 WX189750051 ,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qty: 1 FROM: RDP DrwNo: 216.20.1156.59878 Truss Label: CJ5A JB / WHK 08/03/2020 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Lumber C 12 6 � c� (V � B ih T A = 2X4(A1) D �— 2'4" 411"4 4' 11 "4 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. Snow Criteria (Pg,Pfin PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 6th ed TPI Std: 2014 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(TL): NA HORZ(LL): 0.006 D HORZ(TL): 0.008 D Creep Factor: 2.0 Max TC CSI: 0.775 Max BC CSI: 0.245 Max Web CSI: 0.000 VIEW Ver: 17.02.02A.1213.21 ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 358 / 162 / 329 / - / 157 / 8.0 D 85 /13 /77 !- /- /1.5 C 102 /80 /41 /- !- /1.5 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 D Min Brg Width Req = - C Min Brg Width Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# h� I o • 4� • iA r v No. $6367 i o-A STATE ATE OF*c4,, If0 A L Ens �llbllt16119 FL REG#' 278, Yoonhwak Kim, FL PE #86367 08/03/2020 —WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handling,shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building t Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperly i�id ceiling Locations shown for ermanent lateral restraint of webs shall have bracingp installed per BCSI sections B3, B7 or 610 ile. AfpTy plates to each face oftrussand position as shown above and on the Join Details, unless noted otherwise. f7efer to' 60A-Z for standard plate positions. of ITW BuildiphcLComponents Group 1% shall not be responsible for any deviation from this drawing,anyy failure to build the nee with ANSI PI 1, or for handlin4, shipping, installation and bracing of.trussesA seal on this drawing or cover page . ng indicates acceptance of pro) essionar engineering responsibility solely for the design shown. The suii"ability "awing for any structure is fhe responsibility of the Building Designer per ANSIlTPI 1 Sec.2. ;ee this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst:org; SBCA: www.sbcindustry.com; ICC: www.iccsaf ALPINE ANnw COMPANY 2400 Lake Orange Dr. Suite 150 Orlando FL, 32837 Job Number: N333986 Ply: 1 SEQN: 7024 / T22 / JACK Cust: R8975 JRef: 1WX189750051 ,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D City: 5 FROM: RDP DrwNo: 216.20.1156.58957 Truss Label: CJ3 JB / WHK 08/03/2020 V Loading Criteria (psi) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BOLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: C Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Sot chord 2x4 SP #2 N Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. 2X4(A1) 1r 2'11"4 2' 11 "4 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 6th ed.201 TPI Std: 2014 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE C Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(TL): NA HORZ(LL): 0.001 D HORZ(TL): 0.001 D Creep Factor: 2.0 Max TC CSI: 0.206 Max BC CSI: 0.115 Max Web CSI: 0.000 VIEW Ver: 17.02.01A.1115.21 ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 185 /75 /160 /- /84 /8.0 D 50 /6 /41 /- /- /1.5 C 63 /50 /29 /- /- /1.5 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 D Min Brg Width Req = - C Min Brg Width Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# e,���1ri� AWArh�Pr��, Q �i /- all No. 86367 "p , STATE OF ''O'� 41 �OR10P FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 "'WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT— FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handling,shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building t Safety Information, by TPI and SBCA) fsa shipping, practices prior to performing these functions. Installers shall provide temporary BCSI. Unless noted dtherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperly iid ceilingQ Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, 87 or 610 e._ AppTy plates to each face. oftrussand position as shown above and on the Joint9Details, unless noted otherwise. Refer to' of ITW Buildin Components Group Inc.. shall not be responsible for any deviation from this drawing,an y, failure to build the rice with ANSI 1, or for handling, shipping, installation and bracing of,trussesA seal on this drawirig or cover page , ng indicates acceptance of pro) esslonar engineerinp responsibility solely for the design shown. The suifablli y rawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. ALPINE ANR COWAW 2400 Lake Orange Dr. Suite 150 Orlando FL, 32837 more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com• TPI:_ www.t inst.or : SBCA: www.sbcindustry.com; ICC: Job Number: N333986 ,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Truss Label: CJ3A Ply: 1 ISEQN:7029 / T20 /JACK Cust:R8975 JRef: 1WX189750051 Qty: 1 FROM: RDP DrwNo: 216.20.1157.00564 KD / YK 08/03/2020 Loading Criteria (pst) I Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: C Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #1 Bot chord 2x4 SP #2 N Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NI Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 6th ed.201 TPI Std: 2014 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE C 2' 11 "4 2' 11 "4 Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc Udell U# I Loc R / U / Rw / Rh / RL / W VERT(LL): NA VERT(TL): NA HORZ(LL): -0.003 D HORZ(TL): 0.004 D Creep Factor: 2.0 Max TC CSI: 0.908 Max BC CSI: 0.283 Max Web CSI: 0.000 VIEW Ver: 17.02.02A.1213.21 0 E NS�° m r No. 86367 • P� STATE OF ®cug B 308 / 157 / 309 / - / 113 / 8.0 D 45 /24 /55 /- /- /1.5 C 34 /28 /35 /- /- /1.5 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 D Min Brg Width Req = - C Min Brg Width Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# ORIVr 0,4100N A L k It *o FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 ""WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rjpid ceiling Locations shown for _permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply pfates to each face, otruss and position as shown above and on the Join Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Alpine, a division of ITW Buildinq�Components Group Inc. shall not be responsi¢le for any deviation from this drawing,an`+ failure to build the truss in conformance with ANSI) PI PI 1, or for handl% shipping, installation anal bracing of.trussesA seal on this drawl rrfSg or cover pa e. - listing this drawing indicates acceptance of proTesslonar engineering responsibility solely for the des i n shown. The suit9ability and use of this yawing for any structure is the responsibility of the Building Designer per ANSI/TPl 1 Sec.2. -or more information see this job's general notes page and these web sites:. ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustrv.com: ICC: www.iccsaf ALPINE AN MCOMPANY 2400 Lake Orange Dr. Suite 150 Orlando FL, 32837 Job Number: N333986 Ply: 1 SEQN: 7025 / T24 / JACK Cust: R8975 JRef: 1 WX189750051 ,7A5/320 ,167ED ,RG01 / 1672/ARIAMEAB ELEV.D Qty: 6 FROM: RDP DnwNo: 216.20.1156.59379 Truss Label: CA JB / WHK 08/03/2020 Loading Criteria (psi) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " 43 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP #2 N Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. 12 6 C B Fco M A D 2X4(A1) 1 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: W Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Mist; Criteria Bldg Code: FBC 6th ed.201 TPI Std: 2014 Rep Factors Used: Yes FT/RT:20(0)/l 0(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc Udgfl U# VERT(LL): NA VERT(TL): NA HORZ(LL): -0.000 D HORZ(TL): 0.000 ID Creep Factor: 2.0 Max TC CSI: 0.196 Max BC CSI: 0.025 Max Web CSI: 0.000 VIEW Ver: 17.02.01A.1115.21 ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 143 /79 1148 /- /41 /8.0 D 11 /12 /18 !- /- /1.5 C -15 /32 /27 /- /- /1.5 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 D Min Brg Width Req = - C Min Brg Width Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# III It l l lryrfAWAko.#, Irl No, 86367 d '- STATE OF : �q t11d961uab6 FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 —WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigid cellin Locations shown for ermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or p10, as applicable. Applgy plates to each face ofptruss and position as shown above and on the Join Details, unless noted otherwise. kefer to ALPINE drawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the AN RW COMVRNY truss in conformance with ANSI/TPI 1, or for handlin shippinn, installation and bracing of,trussesA seal on this drawing or cover pa a .. 2400 Lake Orange Dr. listing this drawing indicates acceptance of pro) esstonar engineering responsibility solely for the design shown. The suidbllity g and use of thisrawing for any structure is the responsibility of the uilding Designer per ANSI/TPI 1 Sec.2. Suite 150 For more information see this job's general notes page and these web sites: ALPINE: www.alDineitw.com: TPI: www.toinst.oro: SBCA: www_shcindustrv_com• ICC• www iencafa nm Orlando FL, 32837 Job Number: N333986 Ply: 1 SEQN: 3B43 / T19 HIP_ Cust: R8975 JRef: 1WX189750051 ,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qty: 3 FROM: RWM DrwNo: 216.20.1156.59238 Truss Label: HJ7 TCE / WHK 08/03/2020 Loading Criteria (psi) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " T 4.3 �— VY Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Mean Height: 15.00 It TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 N Bot chord 2x4 SP 2400f-2.OE Webs 2x4 SP #3 Lumber value set "l36" uses design values approved 1/30/2013 by ALSC Loading Hipjack supports 6-11-8 setback jacks with no webs. Wind Wind loads and reactions based on MWFRS. Provide (3) 0.162"x3.5", min toe -nails at top chord. Provide (3) 0.162"x3.5", min toe -nails at bottom chord. 5'3"5 5'3"5 9'10"1 4'6"11 9'2"2 9'22 Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): 0.040 F 999 360 Lu: NA Cs: NA VERT(TL): 0.111 F 999 240 Snow Duration: NA HORZ(LL): 0.010 C - - HORZ(TL): 0.018 C Code / Misc Criteria Creep Factor: 2.0 Bldg Code: FBC 6th ed.20V Max TC CSI: 0.546 TPI Std: 2014 Max BC CSI: 0.416 Rep Factors Used: No Max Web CSI: 0.260 FT/RT:20(0)/10(0) Plate Type(s): VIEW Ver: 17.02.01A.1115.21 WAVE 1`,�ts�illliflPfl�t�®r pN�4WAArcENs s � No. 86367 a ® Ps Or STATE OF �j`S •••Q b 1% /ON+AD 1 e, C. FL REG# 278, Yoonhwak Kim, FL PE #86367 08/03/2020 191 7"14 y 61,1 ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 326 / 154 /- /- /- / 10.6 E 364 /84 /- /0 /0 /1.5 D 214 /177 /- /- /- /1.5 Wind reactions based on MWFRS B Min Brg Width Reg = 1.5 E Min Brg Width Req = - D Min Brg Width Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. B - C 394 - 562 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B - F 531 - 358 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 394 - 583 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathingand bottom chord shall have a propperly attached rigid ceiling Locations shown for ermanent lateral restraint of webs shall have bracin insalled per BCSI sections B3, B7 or B10, as applicable. - AppTy plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. (tefer to ALPINE drawings 160A-Z for standard plate positions. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,an failure to build the aNmvmMvnNv truss in conformance with ANSIQ PI 1, or for handling, shipping, installation and bracing of,trussesA seal on this drawing or cover page , 240o Lake Orange Dr. listing this drawing indicates acceptance of professional engineering responsibility solely for the design shown. The suitability 9 and use of this gnawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 150 For more information see this job's general notes page and these web sites: ALPINE: www.al ineitw.com; TPI: www.t inst.or ; SBCA: www.sbcindust .com: ICC: www.iccsafe.org Orlando FL, 32837 Gable Stud Reinforcement Detail ASCE 7-101 160 mph Wind Speed, 15' Mean Height, Enclosed, Exposure C, Kzt = 1.00 Or, 140 mph Wind Speed, 15' Mean Height, Partially Enclosed, Exposure C, Kzt = 1.00 Or, 140 mph Wind Speed, 15' Mean Height, Enclosed, Exposure D, Kzt = 1.00 Or, 120 mph Wind Speed, 15' Mean Height, Partially Enclosed, Exposure D, Kzt = 1.00 S 2x4 Brace Gable Vertical Spacing Species Grade No Braces (1) Ix4 'L' Brace T( (1) 2x4 'L' Brace w (2) 2x4i 'L' Brace w (1) 2x6 'L' Brace w (2) 2x6 'L' Brace w Group A Group B Group A Group B Group A Group B Group A Group B Group A Group B #1 / #2 3' 10' 6' 7' 6' 10' 7' 9' 8' 1' 9' 3' 9' 7' 12' 2' 12' 8' 14' 0' 14' 0' - S P P #3 3' 8' 5' 9' 6' 2' 7' 8' 7' 11' 9' 1' 9' 6' 12, 0' 12' 6' 14' 0' 14' 0' HF Stud 3' 8' 5' 9' 6' l' 7' 8' 7' 11' 9' 1' 9' 6' 12, 0' 12' 6' 14' 0' 14' 0' O Standard 1 3' 8' 4' 11' 5' 3' 6' 7' 7' 1' 8' 11' 9' 6' 10' 4' 11' 1' 14' 0' 14' 0' #1 4' 0' 6' 8' 6' 11' 7' 10, 8' 2' 9' 4' 9' 8' 12' 4' 12, 9' 14' 0' 14' 0' _J S P #2 3' 10' 6' 7' 6' 10' 7' 9' 8' 1' 9131 9' 7' 12' 2' 12' 8' 14' 0' 14' 0' #3 3' 9' 5' 3' 5' 7' 6' 11' 7' 5' 9' 2' 9' 7' 10, 11' 11' 8' 14' 0' 14' 0' d cu P Stud 3' 9' 5' 3' 5' 7' 6' 11' 7' 5' 9' 2' 9' 7' 10, 11' 11' 8' 14' 0' 14' 0' Standard 3' 6' 4' 7' 4' 11' 6' 2' 6' 7' 8' 4' 8' 11' 9' 8' 10' 4' 13' 1' 14' 0' U _ #1 / #2 4' 5' 7' 6' 7' 9' 8' 10, 9' 3' 10' 7' 11' 0' 13' 11' 14' 0' 14' 0' 14' 0' + _ S P P #3 4' 2' 7' V 7' 9' 8' 9' 9' 1' 10' S' 10, 10' 13' 9' 14' 0' 14' 0' 14' 0' U u P Stud 4' 2' 7' 1' 7' 6' 8' 9' 9' 1' 10, 5' 10' 10' 13' 9' 14' 0' 14' 0' 14' 0' O �I Standard 4' 2' 6' 1' 6' 5' 8' 1' 8' 8' 10, 5' 10, 10, 12' 8' 13' 7' 14' 0' 14' 0' #1 4' 7' 7' 7' 7' 11' 9' 0' 9' 4' 10, 8' 11' 1' 14' 0' 14' 0' 14' 0' 14' 0' S P #2 4' 5' 7' 6' 7' 9' 8' 10, 9' 3' 10' 7' 11' 0' 13' 11' 14' 0' 14' 0' 14' V #3 4' 4' 6' 5' 6' 10' 8' 6' 9' 1' 10' 6' 10' 11' 13' 4' 14' 0' 14' 0' 14' 0' D fr L Stud 4' 4' 6' 5' 6' 10' 8' 6' 9' 1' 10' 6' 10, li' 13' 4' 14' 0' 14' 0' 14' 0' Standard 1 4' 2' 5' 8' 6' 0' 7' 6' 8' 0' 10' 2' 10, 10, 11' 10, 12' 7' 14' 0' 14' 0' Q #1 / #2 1 4' 10' 8' 3' 8' 7' 9' 9' 10' 2' 10' 7' 12' 1' 14' 0' 14' 0' 14' 0' 14' 0' d S P F #3 4' 7' 8' 2' 8' 5' 9' 8' 10' 0' 11' 6' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' U l_ I F Stud 4' 7' 8' 2' 8' 5' 9' 8' 10, 0' 11' 6' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' 0 f� Standard 4' 7' 7' 0' 7' 5' 9' 4' 10, 0' 11' 6' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' X #1 5' V 8' 5' 8' 8' 9' 11' 10, 3' 11' 9' 12' 3' 14' 0' 14' 0' 14' 0' 14' 0' d S P #2 4' 10' 8' 3 8' 7' 9' 9' 10' 2' 11' 7' 12, 1' 14' 0' 14' 0' 14' 0' 14' 0' #3 4' 9' 7' 4' 7' 10' 9' 8' 10, 1' 11' 7' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' .--I D P L Stud 4' 9' 7' 4' 7' 10' 9' 8' 10' 1' 11' 7' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' Standard 4' 7' 6' 6' 6' 11' 8' 8' 9' 3' 11' 6' 12' 0' 13, 7' 14' 0' 14' 0' 14' 0' yautm Abo) able Truss Diagonal brace option, vertical length may be T doubled when diagonal brace Is used. Connect dingonnl brace for 600# 18• 'L• t+iQtQ11j�� at each end. Max web total length Is 14'. Brace E 0 A�' ,�� �9 , �P p Vertical length shown In table above. 114-(as 2x6 DF-L 92 al better diagonal brace, single or double cut shown) at upper end. r 8, L q 0 2/ A - • 6 7 # 1 e Connect diagonal at midpoint of vertical web. Refer to an>�uous' v Bearing— A. chart ab $'c&� mn e t al ,ell v —VARNIN[d® READ AND FV10W ALL NOTES DN THIS DRAVINGIV. --MMRTANTww FLOWSH THIS CONTRACTORSINCL ]DRAWING TO ALL CONTRACTS UDING THE INSTALLERS, Trusses require extreme core In fabricating, handing, shipping, Installing and brodng. Refer to an&W follow the latest edition of BCSI (Building Component Safety Infornatlon, by TPI and SBCA) for safety practices prior to performing these functions. Installers shag provide temporary bracing per BCSL 10, Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a property attached rigid ceRing. Locations shorn for permanent lateral restraint of webs as applicable. Apply plates to each face shall have bracing Installed per BCSI sections the B7 or Details, of truss and passion as shorn above and on the Joint Details, unless noted otherwise. Refer to d—ings 160A-2 for standard plate positions. #® 11 Oi \�O Y A 0 4 b e 0 q / U �d` + p1�� d �, y i1 \:� VVV�,1 IdII�I1j ��r AN ITW COMPAW \ \ 13723\ Riverpod\ Drive \1 Suile\200 Moline, a divislon of ITV Bullding Components Group Inc shall not be responsible for any deviation from this drawing, any failure to bulld the truss In conformance with ANSLITPI 1, or for handling, shipping, Installation L bracing of trusses. A seal on this drawing or cover page listing this drawing, Indicates acceptance of prof � engkweKg resporMbUty solNy for the design shown. The sultoblUty and use of this dra for any structure Is the resporrsa," of the Binding Designer per ANSI/TPI 1 Sec.P \1 Maryland\ Heights.\ MO\ 63043 For more Information see this ,Job's general rates ppage and these web sites, ALP➢E, wwr.atpineltw,coni TPL w tpinstorgi SBCA, wwr.sbcindustryorgi ICC,--Jccsnfe.org Bracing Group Species and Grades, Group A, S ruce-Pine-Fir Hen-Flr #I / #2 Standard 1 #2 Stud #3 Stud 1 #3 i1standard ➢ou las Fir -Larch Southern Plnewww #3 #3 Stud Stud Standard Standard Group B, Hen -Fir #1 8 Btr #1 Douglas Fir -Larch Southern Plnewww #1 #1 #2 #2 Ix4 Braces shall be SRB (Stress -Rated Board). wwFcr lx4 So. Pine use only Industrial 55 or Industrial 45 Stress -Rated Boards. Group H values may be used with these grades. Gable Truss Detail Notes, Wind Load deflection criterion Is L/240, Provide uplift connections for 75 plf over continuous bearing (5 psi TC Dead Load). Gable end supports load from 4' 0' outlookers with 2' 0' overhang, or 12' plywood overhang. Attach 'L' braces with 10d (0.128'x3.0' min) nails. X For (1) 'L' brace, space nails at 2' o.c. In 18' end zones and 4' o.c. between zones. iK)Wor (2) 'L' braces, space nalls at 3' o.c. In IS' end zones and 6' o.c. between zones. 'L' bracing must be a minimum of 807 of web member length. Gable Vertical Plate Sizes Vertical + Refer to common truss design for peak, splice, and heel plates. Refer to the Building Designer for conditions not addressed by this detail. REF ASCE7-10-GAB16015 DATE 10/01/14 DR W G A16015ENC101014 Len th No Slice Less than 4' 0' 2X3 Greater than but 3X4 less than Greater than 11' 6' 4X4 Rl� TOT. LD. 60 PSF AX. SPACING 24.0' 0178, Yoonhwak Kim, FL PE #86367 TOT. LD. 60 PSF AX. SPACING 24.0' 0178, Yoonhwak Kim, FL PE #86367 Gable Stud Reinforcement Detail ASCE 7-101 180 mph Wind Speed, 15' Mean Height, Enclosed, Exposure C, Kzt = 1.00 Ori 160 mph Wind Speed, 15' Mean Height, Partially Enclosed, Exposure C, Kzt = 1.00 Orl 160 mph Wind Speed, 15' Mean Height, Enclosed, Exposure D, Kzt = 1.00 Ort 140 mph Wind Speed, 15' Mean Height, Partially Enclosed, Exposure D, Kzt = 1.00 S 2"Brace Gable Vertical pacing I Species I Grade No Braces (1) lx4 'L' Brace w (1) 2x4 'L' Brace 0(2) 2x4 'L' Brace rr (1) 2x6 'L' Brace w (2) 2x6 'L' Brace r Group A Group B Group A Group B Group A Group B Group A Group B Group A Group B r #1 / #2 3' 6' 6' 0' 6' 3' 7' 1' 7' 4' 8' 5' 8' 9' Il' 1' 11' 7' 13' 3' 13' 9' 0) U S f #3 3' 4' S' 1' S' S' 6' 9' 7' 3' 8' 4' B' 8' 10' 7' 11' 4' 13' 1' 13171 H P Stud 3' 4' 5' 0' 5' 4' 6' 9' 7' 2' 8' 4' 8' 8' 10, 6' 11' 3' 13, 1' 13' 7' 0 Standard 1 3' 4' 4' 4' 4' 7' 5' 9' 6' 2' 7' 10' 8' S' 9' 1' 9' 8' 12' 4' 13' 2' #1 3' 8' 6' 1' 6' 4' 7' 2' 7' 5' 8' 6' 8' 10, 11' 3' 11, 8' 13' 4' 13, 11' J S P #2 3' 6' 5' 9' 6' 2' 71' 7' 4' 8' 5' 8' 9' 11' 1' 11' 7' 13' 3' 13' 9' #3 3' 5' 4' 7' 4' 10' 6' 1' 6' 6' 8' 2' 8' 9' 9' 6' 10' 2' 12' 11' 13' 8' d F Stud 3' 5' 4' 7' 4' 10' 6' 1' 6' 6' 8' 2' 8' 9' 9' 6' 10' 2' 12' 11' 13' 8' Standard 3' 1' 4' 0' 4' 3' 5' 4' 5' 9' 7' 3' 7' 9' 8' 5' 9' 0' 11' 5' 12' 3' U #1 / #2 4' 0' 6' 10' 7' 2' 8' 1' 8' S' 9' 8' 10' 1' 12' 9' 13' 3' 14' 0' 14' 0' - _ S P P #3 3' 10' 6' 2' 7' 2' 8' 0' 8' 4' 9' 7' 9' ill 12' 7' 13, 1' 14' 0' 14' 0' U LJ P Stud 3' 10' 6' 2' 6' 7' 8' 0' 8' 4' 9' 7' 9' 11' 12' 7' 13' 1' 14' 0' 14' 0' O Hl Standard 1 3' 10' 5' 4' 5' 8' 7' 1' 7' 7' 9' 7' 9' 11' ill 1' 11' 11' 14' 0' 14' 0' \ #1 4' 3' 7' 0' 7' 3' 8' 3' 8' 6' 9' 9' 10, 2' 12' 11' 13' 5' 14' 0' 14' 0' / S P #2 4' 0' 6' 10, 7' 2' 8' 1' 8' 5' 9' 8' 10, 1' 12, 9' 13' 3' 14' 0' 14' 0' #3 3' 11' 5' 7' 5' 11' 7' 5' 7' 11' 9' 7' 10' 0' 11' B' 12' 6' 14' 0' 14' 0' QJ D P L Stud 3' 11' 5' 7' 5' 11' 7' 5' 7' 11' 9' 7' 10, 0' 11' 8' la, 6' 14' 0' 14' 0' Standard 3' 9' 4' 117 5' 3' 6' 7' 7' 0' 8' 11' 9' 6' 10' 4' 11, 1' 14' 0' 14' 0' #1 / #2 4' 5' 7' 7' 7' 10' 8' 11' 9' 3' 9' 8' 11' 1' 14' 0' 14' 0' 14' 0' 14' 0' d _ S P P #3 4' 3' 7' 2' 7' 7' 8' 10, 9' 2' 10' 6' 10, 11' 13' 10' 14' 0' 14' 0' 14' 0' U I I P Stud 4' 3' 7' 1' 7' 7' 8' 10, 9' 2' 10' 6' 10, 11' 13' 10' 14, 0' 14' 0' 14' 0' 0 I I Standard 4' 3' 6' 2' 6' 6' 8' 2' 8' 9' 10' 6' 10, 11' 12, 10, 13' 9' 14' 0' 14' 0' X 7' 8' 7' 11' 9' 0' 9' 5' 10, 9' 11' 2' 14' 0' 14' 0' 14' 0' 14' 0' d S P #2 4' 5' 7' 7' 7' 10' 8' 11' 9' 3' 10, 8' 11' 1' 14' 0' 14' 0' 14' 0' 14' 0' #3 4' 4' 6' 5' 6' 10' 8' 7' 9' 12' 10' 7' 11' 0' 13' 5' 14' 0' 14' 0' 14' 0' .--I r D f L Stud 4' 4' 6' 5' 6' 10, 8' 7' 1 9' 12' 1 10' 7' 11' 0' 13' 5' 14' 0' 14' 0' 14' D' Standard 4' 3' 5' 8' 6' 1' 1 7' 7' 1 8' 1' 1 10' 3' 10' 11' 11' 11' 1 12' 9' 1 14' 0' 14' 0' Alacta able Truss Diagonal brace options vertical length may be T doubled when diagonal IB• brace Is used. Connect .L diagonal brace for 775aat each end, •L• �g�4llPf►�� total length IsN14', web Bracee - 2x6 DF-L #2 or /�IXI better diagonal T_ Vertical length shown bracei single In table above. or double cut • 45' (as shown) at e upper end. Connect diagonal nt ontuouspBenring mid olnt of vertical web. Refer to chart abA ma e t al l WVARItONG-w READ MID FOLLOW ALL LUTES ON THIS DmwDn v —DVMTAHT— FIJIRNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTA:: M a oo Trusses require extreme core In fabricating, handling, shipping, Installing and bradng• Refer to one®, /�(: follow the latest edition of SCSI (Building Conponent Safety Information, by TPI and SBCA) far safety 4LL practices prior to performhg these functions. Installers shall provide tenpornryy 6rnchp per BCSI. Unless noted otherwise, top chord shall have properly attached structural shenthhg and bottom chord d✓ S d wr shall have a properly attached rigtd ceiling. Locations shown for pernanent lateral restraint of webs �f�l Ji'jAr l d �r;1� shall have bracing installed per above sections the J or DBIG,et s applicable. Apply prates to each face / �Jj H �l'r�LUJ_'�JJ of truss and position -Z shown above and on the Joint DetMs, unless noted otherwise. U Refer to drawings 160A-Z for standard plate positions. AN LOIN COMPANY this Alpine, division of ITV Building Corponents Group Inc shall not be responsible for any deviation from Installntiong, my braf allureg of to build the truss In conformance wlth ANSMPI 1, or for handling, shipping, A seal on this drawing or cover page L6-" this drawing, bwOcates acceptance of professional \ \ 13723\ Riverport\ Drive engkleeNng resparubdtty solely for the design shown The suitability and use of this drawkV 1 \ Suite\ 200 far any strucbre is the responslMlity of the Budding Deslgr a per ANSI/TPI 1 SecP. \\Maryland\Heights,\MO\63043 For more Information see this Job's general notes page arW these web sitesi ALPINE w—atpineltw.coni TPD wwwhpins4ora) SBCA, — edustrvarol ICO vdccsafe.oro Bracing Group Species and Gradesi Group At S ruce-Pine-Fir Hen -Fir #1 / #2 Standard #2 Stud #3 Stud #3 Stnndnrd Dou ins Fir -Larch Southern Plnewww #3 #3d S Stutud Standard Standard Group Bi Hem -Fir #1 & Btr #1 Douglas Fir -Lurch Southern Plnermst #1 #1 #2 #2 Ix4 Braces shall be SRB (Stress -Rotted Board). wwFor Ix4 So, Pine use only Industrial 55 or Industrial 45 Stress -Rated Boards. Group B values may be used with these grades. Gable Truss Detail Notes: Wind Load deflection criterion Is L/240. Provide uplift connections for 100 plf over continuous bearing (5 psf TC Dead Load). Gable end supports load from 4' 0' outlookers with 2' 0' overhang, or 12' plywood overhang. Attach 'L' braces with 10d (0.128'x3.0' min) nails. ill: For (1) 'L' brace- space nails at 2' o,c. In 18' end zones and 4' o.c. between zones. )K)KFor (2) 'L' braces, space nails at 3' o.c, In 18' end zones and 6' o,c, between zones. 'L' bracing must be at minimum of 807 of web member length. Gable Vertical Plate Sizes Vertical Length No Slice Less than 4' 0' 2X3 Greater than 4' 0" but 4X4 Less than 10' 0' + Refer to common truss design for peak, splice, and heel plates, Refer to the Bullding Designer for conditions not addressed by this detail. REF ASCE7-10-GAB18015 DATE 10/01/14 DRWG A18015ENC101014 TOT. LD, 60 PSF SPACING 24,0' Yoonhwak Kim, FL PE #86367 I 'T' Reinforcing Member Gable Truss Gable Detail For Let -in Verticals Gable Truss Plate Sizes ppropriate Alpine gable detail for e sizes for vertical studs. Engineered truss design for peak, b, and heel plates, vertical plates overlap, use a to that covers the total area of sapped plates to span the web. 2*2X4' *2X8 Hrovlde connections for uplift specified on the engineered truss design. Attach each 'T' reinforcing member with End Driven Nnilsl 10d Common (0,148'x 3.',min) Nails at 4' o,c, plus (4) nails In the top and bottom chords. Toenalled Nallsl 10d Common (0,148'x3',min) Toenails at 4' o,c, plus (4) toenails In the top and bottom chords. This detail to be used with the appropriate Alpine gable detall for ASCE wind load. ASCE 7-05 Gable Detail Drawings A13015051014, A12015051014, A11015051014, A10015051014, A14015051014, A13030051014, A12030051014, A11030051014, A10030051014, A14030051014 ASCE 7-10 & ASCE 7-16 Gable Detail Drawings r A11515ENC100118, A12015ENC100118, A14015ENC100118, 0 III A18015ENC100118, A20015ENC100118, A20015END10011� A11530ENC100118, A12030ENC100118, A14030ENC1 i1rQ WNIC10f�19,• f("� A18030ENC100118, A20030ENC100118, A20030EN �� S11515ENC100118, S12015ENC100118, S14015EN 0118 �16 0 3Q] S18015ENC100118, S20015ENC100118, S20015EF$110011� S 0 i5P 1 8 S11530ENC100118, S12030ENC100118, S140302C1001I8, S J 1► S18030ENC100118, S20030ENC100118, S2003 0118, S2003OPED100118 6 Seeappropriate Alpine gable detall for maxlmZ unrlRlnfarcedO§e®Lertical 1p mVARN Mao READ AND FOLLnV ALL wren ON THIS DRAVnm ■ DFMTAMT" FURNISM THIS DRAVIw TD ALL 6WnZACTI3RS WCLUDING THE INSTALLERS. /^\\ Trusses require extreme care In fabricating, handling, shipping, Installing and bracing, Refer to anfolio.d V Fold the latest edition mi SCSI (Bultosee ng Component Safety shalt provide a or and bracing far safety practices prior to performing there functions. Installers shall provide temporary brndng per BLSL Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom cho w, shall have a properly attached rigid ceRing• Locations shown for permanent lateral restraint of we shall have bracing Installedss per, BCSI sections the B7 or Beta as applicable.no Apply plates to each fac �l���rLL�JrJ �I luj�\vll of truss and position -Z shown above and on the Joint Details, unless noted otherwise. ReFer to drawings 160A-Z for standard plate positions. Alpine, a division of ITV Building Components Group Inc shall not be responsible for any deviation fr AN ITW COMPANY this drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shipping, Installation & bracing of trusses. A seal on this dI or cover page llsti g this drawing, ind1cates acceptance of professlonnl %% 13723\ Riverpon\ Drive engineering responsibility sotely for the design shown. The suitability and use of this dmuing \\Suite%200 for' any structure is the responsMty of the "dig Designer, per ANSI/TPI 1 SecP_ Q %\ Maryland\ Heights,% M0%63043 For more Information see this Job's general notes page and these web st�6�°7 ALPINEi www.alpineltw.coml TPIi www.tpinst,orgl SBCAi www.sbcindustry,orgl ICO wwwl STATE OF rtl Q `A, ,�41, e 'T' Reinforcement Attachment Detail 'T' Reinforcing 'T' Reinforcing Member Member Toe -null - Or - IN End-nnll To convert from 'L' to 'T' reinforcing members, multiply 'T' Increase by length (based on appropriate Alpine gable detall). Maximum allowable 'T' reinforced gable vertical length Is 14' from top to bottom chord. 'T' reinforcing member material must match size, specie, and grade of the 'L' reinforcing member, ✓eb Length Increase w/ 'T' Brace 'T' Relnf, Mbr, Size 'T' Increase 2x4 30 2x6 20 Examples ASCE 7-10 Wind Speed = 120 mph Mean Roof Height = 30 ft, Kzt-= 1,00 Gable Vertical = 24'o,c. SP #3 'T' Reinforcing Member Size = 2x4 'T' Brace Increase (From Above) = 30% = 1,30 (1) 2x4 'L' Brace Length = 8' 7' Maximum 'T' Reinforced Gable Vertical Length 1.30 x 8' 7' = 11' 2' e_ MAX, T❑T, LD, 60 PSF DUR, FAC, ANY MAX. SPACING 24,0' REF LET -IN VERT DATE 01/02/2018 DRWG GBLLETIN0118 'T' Reinforcing Member Gable Truss Gable Detail For Let -in Verticals Gable Truss Plate Sizes ppropriate Alpine gable detail for :e sizes for vertical studs. Engineered truss design for peak, rb, and heel plates. vertical plates overlap, use a ,te that covers the total area of lapped plates to span the web, e: 2*2X4 2X8 Provide connections for uplift specified on the engineered truss design Attach each 'T' reinforcing member with End Driven Nalls, 10d Common (0.148'x V,min) Nalls at 4' o.c. plus (4) nails In the top and bottom chords, Toenalled NaRsi 10d Common (0.148'x3',min) Toenails at 4' o.c, plus (4) toenails In the top and bottom chords. This detail to be used with the appropriate Alpine gable detail for ASCE wind load, ASCE 7-05 Gable Detail Drawings A13015051014, A12015051014, A11015051014, A10015051014, A14015051014, A13030051014, A12030051014, A11030051014, A10030051014, A14030051014 ASCE 7-10 Gable Detail Drawings ee A11515ENC101014, A12015ENC101014, A14015ENC101014, 91 CX14110o. A18015ENC101014, A20015ENC101014, A20015END101 % 1�4� rr0 A11530ENC101014, A12030ENC101014, A14030ENC1 Q€MCD1®16,• /rl P A18030ENC101014, A20030ENC101014, A20030EN1�1Ql�} Aa0 3 �► S11515ENC100815, S12015ENC100815, S14015E1�100815e�51 0 •S� S18015ENC100815, S20015ENC100815, S200155OD1008JI5, 015P D 8 e S11530ENC100815, S12030ENC100815, S1403004C100015, 0 t S18030ENC100815, S20030ENC100815, S20030EWOU815, S20030PED100815 F Seeappropriate Al ine 77�rC . p gable detail for mnxlma�wl unrRlnforced"Tj'eMerticnl to a, a STATE (W a 'T' Reinforcement Attachment Detail 'T' Reinforcing 'T' Reinforcing Member Member Toe-nall - Or - End -null To convert from 'L' to 'T' reinforcing members, multiply 'T' Increase by length (based on appropriate Alpine gable detail). Maximum allowable 'T' reinforced gable vertical length Is 14' from top to bottom chord. 'T' reinforcing member material must match size, specle, and grade of the 'L' reinforcing member, ✓eb Length Increase w/ °T° Brace 'T' Relnf. Mbr, Size 'T' Increase 2x4 30 2x6 20 Examples ASCE 7-10 Wind Speed = 120 mph Mean Roof Height = 30 ft, Kzt = 1.00 Gable Vertical = 24'o,c. SP #3 'T' Reinforcing Member Size = 2x4 'T' Brace Increase (From Above) = 30% = 1.30 (1) 2x4 'L' Brace Length = 8' 7' Maximum 'T' Reinforced Gable Vertical Length 1.30 x8'7'=11' 2' d I�LJ�J ��[�� w=DWMTANT" FISH nuSSDDMVING AND m°ALiL�CONTRACTORs asunING � INSTALLERS. P�i� Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. Refer to and follow the latest edition of HCSI (Building Component Safety Information, by TPI and SHCA) for safety practices prior to performing these functions. Installers shall provide temporary bra Ing per BCSL Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a property attached rigid ceiling. Locations shown for permanent lateral restraint of webs se shall have bracing Installed per above sections the B7 Joint let as applicable. Apply plates to each face of truss and position all shorn above and an the Joint 1110, s, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. /C` ps: `QR�'� « �`�� 4 ® I� S d ® ° /t y + 4rj f'�jr VV //eft (b'� 1 (- REF LET -IN VERT DATE 10/01/14 DRWG GBLLETIN1014 AN 1TW COMPANY 1113723\Riverpon\Drive "Suite1200 \lMarylantl\Heighls,\M0163043 Alpine, a division of ITV Building Components Group Inc shall not be responsible for any deviation from this drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shipping, Installation 6 bracing of trusses. A seal on this drawing or cover page Ustig this drawng, Indicates acceptance of professional e.glneering responsblllty solely for the deign shown. The swtabuty and use of this drawing for' any struchre Ls the responsblllty of the "ding Designer per ANSI/TPI 1 SecZ Far more Information see this Job's general notes page and these rev sI ftW78 ALPINE. vr.alpineitr.con) TPh vw.tpinst,orgl SHCN vwsbclndustryarg) ICG wr.c s Yoonhwak Kim, FL PE #86367 AX, TOT, LD, 60 PSF DUR, FAC, ANY MAX, SPACING 24,0' Valley Detail - ASCE 7-10: 160 mph, Top Chord 2x4 SP #2N, SPF #1/#2, DF-L #2 or better, Bot Chord 2x4 SP #2N or SPF #1/#2 or better. Webs 2x4 SP #3, SPF #1/#2, DF-L #2 or better, "Attach each valley to every supporting truss with) (2) 16d box <0,135' x 3,5') nails toe -nailed for ASCE 7-10 160 mph. 30' Mean Height, Enclosed Building, Exp, C, Wind TC DL=5 psf, Kzt = 1.00 Or ASCE 7-10 140 mph, 30' Mean Height, Enclosed Building, Exp. D, Wind TC DL=5 psf, Kzt = 1.00 Bottom chord may be square or pitched cut as shown, Valleys short enough to be cut as solid triangular members from a single 2x6, or larger as ,required, shall be permitted in lieu of fabricating from separate 2x4 members, All plates shown are ITW BCG Wave Plates, 3X4 12 12 Max, I 2X4 X4 . 8-0-0 max 4X4 12 12 Max, I 1X3 30' Mean Height, Enclosed, Exp, C, Kzt=1,00 Unless specified otherwise on engineer's sealed design, for vertical valley webs taller than 7-9' apply 2x4 'T' reinforcement, 80% length of web, same species and grade or better, attached with 10d box (0.128' x 3L0') nails at 6' o,c, In lieu of 'T' reinforcement, 2x4 Continuous Lateral Restraint applied at mid -length of web is permitted with diagonal bracing as shown in DRWG BRCLBANC1014. Top chord of truss beneath valley set must be braced with: properly attached, rated sheathing applied prior to valley truss installation, Or Purlins at 24' o,c. or as otherwise specified on engineer's sealed design Or By valley trusses used in lieu of purlin spacing as specified on Engineer's sealed design, www Note that the purlin spacing for bracing the top chord of the truss beneath the valley is measured along the slope of the top chord, ++ Larger spans may be built as long as the vertical height does not exceed 14'-0'. Valle Spacing Pitched Cut Square Cut Bottom Chord Bottom Chord Valley Toe -nailed Valle / y ss 1X3 (Max Spacing) a1X3 5X4/SPL _1X3 2X4 20-0-0 (++) Supporting trusses at 24' o,c, maximum spacing. sp 4 •° 4 • ® No, me e 2X4 Stubbed Valley End Detail T oAmd)n I T 4X4 Optional Hip Joint Detail �u�s1e� Partial Framing Plan -OWARN M90 RFAB AM FDLLOW ALL NaTrS DN THIS DRAWRO a 41CIRTANIw■ FURNISH THIS DRAVD46 TII ALL CnNIRAMRS RM.TJI M THE IWTALLM � W I rli i LL yr + ® 'Mr� .L 30 30 40 PSF REF VALLEY DETAIL Trusses require extreme cnrc N fabricating, handling, shipping, Installing and bracing. Refer to and follow the latest edition of BCSI ®ulding Component Safety Information, by TPI and SBCA) for safety p �p �� + v 1D 20 15 7 PSF DATE 10/O1/2014 practices prior to performing these functions. Installers shall provide temporary bracing per BCSL V�1�� ® �� 0 C 0 DRWG VAL160101014 /jjj r1�L� FI� Unless noted otherwise, top chord shalt have properly attached structural sheathing and bottom chord shall have a properly attached rlgld celing. Locations shown for permanent lateral restraint of webs shad hove brndng Installed per BCSI sections or B10, as Apply plates to each face de Ss o * e der+ /Pi p m y Yee, C D 10 10 10 PSF �Q�II Ili ON AL the J unlesnble. of truss nndwiposltlon as shorn above and on the Joint Oetnlls, unless noted otherwise. �`/l`Jrd BC L 0 0 0 PSF V Refer to dra ngs 160A-Z for standard plate positions. /\PI �l W COMPANY Alpine, a division of ITV Bullding Compments Group Inc. shall not be responsible for any deviation from this drawing, any falure to bulld the truss In conformance with ANSI/TPI 1, or for handling, shipping, T❑TL DL 60 55 57PSF Installntlon li brnclnp of trusses. A seal on this drawing or cover page listing this drawing, g, Indicates acceptance of professional DUR.F .IL25/1.33 5 1.15 1113723% Riverporh Drive englneerirg resPonsWittyy solely far the design shorn The sLdtabiOty and use of this drawing for any structcx is t e rcsporhskJUty of the Buldtrp Designer Per ANSI/TP1 I S e'= 1\Suite1200 \1Marylandll Heights,\M0163043 Fm more Inf—tiro see this Job's general notes page and these web sltesc ALPINE ww—Wneitw.eonl TPI- nw,tpinst.orgi SBCA- wwwsbdndustry.orgi ICD wvdcrsafe.org SPA ING E24. 0' ft./W I.78, Yoonhwak Kim, FL PE 486367 I VALLEY FRAMING & BRACING DETAIL I RI BC `/2 of Lumber Size and Grade Minumum Requirements GENERAL NOTES Purlins required 2'-0" O.C. in absence of plywood sheathing. Trusses without sheathing applied must be evaluated accordingly. Purlins should overlap sheathing one truss spacing minimum. In cases that this is Impractical, overlap sheathing a minimum of 6", and nail upwards through sheathing into purlin with a minimum of 8-8d (0.131"x2.5") common wire nails. Effects of not providing sheathing below a valley set must be evaluated by the building designer. This drawing applies to valleys with the following conditions: Spans (distance between heels) 40'-0" or less -Maximum valley height: 14'-0" -Maximum mean roof height: 30 feet -ASCE 7-05, 140 mph, Enclosed, Cat 11, Exp B,1=1.0, Kzt=1.0 -Or A Maximum of ASCE 7-10, 180 mph, Enclosed, Exp D, Kzt=1.0 TRUSS TRUSS UNDER VALLEY FRAMING VALLEY RAFTER OR RIDGE ® +CRIPPLE ripples 4'-0" for 30 psf (TL) and 20 psf (TD) Max. ;e the crippes for each row starting from the valleys or sleepers working inward to the ridge board so that cripple locations are gored between rows. Typ) innection Requirement Notes 2x6 rafters to ridge 416d toe -nails Cripple to ridge 416d toe -nails Cripple to rafter 4 16d toe -nails (**) 816d face -nails Rafter to sleeper or blocking 5 16d toe -nails Rafter to two 2x6 sleepers 416d toe -nails Sleeper to truss 416d toe -nails Two 2x6 sleepers to truss 3 16d toe -nails each sleeper & truss Ridge board to roof block 416d toe -nails Ridge board to truss 416d toe -nails Purlin to (Typ) 3 16d toe -nails Truss to blocking 416d toe -nails Truss to cripple 416d toe -nails Truss to cripple 416d toe -nails Cripple to purlin 316d toe -nails "" ""'"""" " ""` " �` " `"i 13. Collar beam to rafter 416d toe -nails CRIPPLE, BRACING, & BLOCKING NOTES NOTE: 16d (0.162"x3.5") COMMON NAILS -2x4 continuous lateral restraint (CLR) min. is required for cripples V-0" to 10'-0" long nailed w/ 2 -10d (0.148"x3") nails. Or 2x4 "T" or scab reinforcement nailed to flat edge of cripple with 10d f0.128"x3.0") nails at 6" o.c. 'T' or scab must be 90% of cripple length. Cripples over 10'-0' long requre two CLR's or both faces w/'T' or scab. Use stress graded lumber & box or common nails. ;Narrow edge of cripple can face ridge or rafter, as long as the proper number of nails are Installed into ridge board -Install blocking under rafter if sleepers are not used. -Install blocking under cripples If cripples fall between lower truss top chords and lateral bracing is not used. -Apply all nailing In accordance to current NDS requirement�Ni Nails are common wire nails unless noted otherwise. A N, `• ••Nahee• / �i WARIM4G" READ AND FMI" ALL NAILS DN WS DRAVRQ ..OPO2TANTa FLRN= THIS DRAVM To ALL CUKRACIP[M aryrmor. THE MSTALLERS Trusses require extreme care h fobricatkq tandllnp shippkq, Installkp and brackg •Refer toran Fahey the latest edition rl SCSI (BulcUrgfun Corqpions. Int Safety all protlon. a or and SBCArosin for CO. practices prior to l ise, top these all have Installers the proNde inat sheathing ng C d per n % UNcss noted otherrise, top chord shop have properly attached structural taterat r and bat of i� l stall have a properly attached SCSI celUng. Locations shorn for perronent lateral restrant of fI T7 ^ r] stall have post Installed per SCSI sectlu n the 87 or Dle, as uril bno Apply plates to each fog I � I�f�\VI I of truss and position as shosn above o� on t �o fart Detals, unless noted otherwise. Refry to draehps 16GA-Z for standard etr Alpke, o o"slm of ITV Budding Components Croup Inc. shall rot be responsbtr for ony deviation IF AN ITWCOMPANY this d^arhg, any fnlure to build the truss In confornonce rlth ANSVIPI 1, or for hwxUV, shipping, Installatkxi 6 bradng of trusses. A seal an this`dms#ig or cover page Nsthp this drarky. Indicates a¢eptuice of professkerol crokeer+ip re�eramllty sold for the drs7pn sham TFr Shp 13389 Lakelronl0me for' arty ctr�c Is tM resporm6ilty of tfr Atdrp Desigrrr pry Attn MI 1 Sec' � Earth City, MO 63675 For rorr hfornatlen see this Job's general net gpaape and ttece rob sit— ALPDEr rrralpleltrtoru TPIi —Apil tor3i SBCM m.sbdndustrYOrGI ICO m.hrsafearo STATE OF '.•: V R 1Or• r SKr..•• ����` s`ONALE ?O( (A) (B) (**) LL 20 30 40 54 IREF VALLEY FRAMING DL 10 20 7 7 JDATE 10/01/14 $C DL 0 0 0 0 1 DRWG VACNV1801015 BC LL 0 0 0 0 TOT. LD.30 50 47 61 DUR. FAC. 1.25/1.15 SPACING SEE ABOVE