HomeMy WebLinkAboutEnergy Code,�>s ��er�►r��_ ©(,, 14�-5 -FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KING RESIDENCE Builder Name: K & S INDUSTRIES Street: 66co •-68MPEACOCK ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE, FL, 34987 Permit Number: Owner: DANIELLE KING Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2052.0 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Ext Insul, Exterior R=4.1 1844.00 ft2 b. Frame - Wood, Adjacent R=11.0 208.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 5 d. N/A R= ft2 10. Ceiling Types (2902.0 sqft.) Insulation Area 5. Is this a worst case? No a Roof Deck (Unvented) R=20.0 2902.00 ft2 6. Conditioned floor area above grade (ft2) 2902 b. N/A R= ft2 c. N/A R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. W indoors (289.2 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 140 a. U-Factor: Sgl, U=0.65 241.20 ft2 b. Sup: Attic, Ret: Attic, AH: Garage 6 130 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 48.00 ft2 12. Cooling systems kBtu/hr Efficiency a. Central Unit 29.4 SEER:16.00 SHGC: SHGC�.30 b. Central Unit 23.6 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 8.432 ft. Area Weighted Average SHGC: 0.258 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2902.0 sgft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2902.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Area: 0.100 Total Proposed Modified Loads: 85.19 PASS Glass/Floor Total Baseline Loads: 85.39 I hereby certify that the plans and specifications covered by Review of the plans and 't S�AT`p this calculation ar specifications covered by this O� Code. calculation indicates compliance with the Florida Energy Code. ti rm� ��� •.; r3�s�.'� ,� O PREPARED BY Before construction is completed DATE' 1-13- this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as d=ed'pliance Florida Statutes. CAD with the Florida Energy e. WE'D OWNER/AGENT"-BUILDING OFFICIAL: DATE: P �31� Z DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 1/12/2021 3:52 PM EnergyGaugeAO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7 'Ili 4f—o96da—CYv FORM R405-2017 INPUT SUMMARY UHI:L;KLI5I RtF'UR I PROJECT Title: KING RESIDENCE Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 2902 Lot # Owner Name: DANIELLE KING Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: 6bo0 Builder Name: K & S INDUSTRIES Rotate Angle: 0 Street: 8WWPEACOCK ROAD Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: PORT ST LUCIE, Family Type: Detached FL, 34987 New/E)asting: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 1601 12808 2 AHU 2 1301 13688 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 278 2224 No 0 1 1 Yes Yes Yes 2 M TOILET 30 240 No 0 1 Yes Yes Yes 3 M BATH 124 992 No 0 1 Yes Yes Yes 4 M HALL 68 544 No 0 1 No Yes Yes 5 HALF BATH 36 288 No 0 1 No Yes Yes 6 M WIC 99 792 No 0 1 Yes Yes Yes 7 CLST 2 18 144 No 0 1 No Yes Yes 8 BEDROOM 2 177 1416 No 0 1 1 Yes Yes Yes 9 BEDROOM 3 182 1456 No 0 1 1 Yes Yes Yes 10 WIC 3 28 224 No 0 1 No Yes Yes 11 WIC 4 28 224 No 0 1 No Yes Yes 12 BEDROOM 4 169 1352 No 0 1 1 Yes Yes Yes 13 BEDROOM 5 238 1904 No 0 1 1 Yes Yes Yes 14 CLST 5 28 224 No 0 1 Yes Yes Yes 15 SINKS 49 392 No 0 1 No Yes Yes 16 TOILET RM 49 392 No 0 1 No Yes Yes 17 HALLWAY 139 1112 No 0 1 No Yes Yes 18 KITCHEN 360 4320 Yes 0 1 Yes Yes Yes 19 FOYER 90 720 No 0 1 Yes Yes Yes 20 FAMILY ROOM 460 5520 No 0 1 Yes Yes Yes 21 UTILITY RM 98 784 No 0 1 No Yes Yes 1/12/2021 3:52 PM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software . Page 2 of 7 i"1AS-1-ce 'Maj-)rr aura - 0(" i g FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES • Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 ENTRY 104 832 No 0 1 Yes Yes Yes 23 PANTRY 50 400 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 34 ft 0 278 1t2 _--- 1 0 0 2 Slab -On -Grade Edge Insulation M TOILET 6 ft 0 30 ft2 _--- 1 0 0 3 Slab -On -Grade Edge Insulation M BATH 8 ft 0 124 ft2 ___- 1 0 0 4 Slab -On -Grade Edge Insulation M HALL 1 ft 0 68 ft2 -___ 1 0 0 5 Slab -On -Grade Edge Insulation HALF BATH 1 ft 0 36 ft2 -_-- 1 0 0 6 Slab -On -Grade Edge Insulation M WIC 20 ft 0 99 ft2 ---- 1 0 0 7 Slab -On -Grade Edge Insulation CLST 2 1 ft 0 18 ft2 ___- 1 0 0 8 Slab -On -Grade Edge Insulation BEDROOM 2 18 ft 0 177 ft2 _-__ 1. 0 0 9 Slab -On -Grade Edge Insulation BEDROOM 3 13 ft 0 182 f12 ---_ 1 0 0 10SIab-On-Grade Edge Insulation WIC 3 1 ft 0 28 ft2 --__ 1 0 0 11SIab-On-Grade Edge Insulation WIC 4 1 ft 0 28 ft2 ___- 1 0 0 12SIab-On-Grade Edge Insulation BEDROOM 4 19 ft 0 169 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulation BEDROOM 5 31 ft 0 238 ft2 _ - 1 0 0 14SIab-On-Grade Edge Insulation CLST 5 i ft 0 28 ft2 ____ 1 0 0 15SIab-On-Grade Edge Insulation SINKS 1 It 0 49 ft2 _-__ 1 0 0 16SIab-On-Grade Edge Insulation TOILET RM 1 ft 0 49 ft2 __-_ 1 0 0 17SIab-On-Grade Edge Insulation HALLWAY 1 ft 0 139 ft2 ---_ 1 0 0 18SIab-On-Grade Edge Insulation KITCHEN 18 ft 0 360 ft2 --__ 1 0 0 19SIab-On-Grade Edge Insulation FOYER 5 ft 0 90 ft2 ____ 1 0 0 20SIab-On-Grade Edge Insulation FAMILY ROOM 23 ft 0 460 ft2 _--- 1 0 0 21SIab-On-Grade Edge Insulation UTILITY RM 1 ft 0 98 ft2 ____ 1 0 0 22SIab-On-Grade Edge Insulation ENTRY 4 ft 0 104 ft2 ---- 1 0 0 23SIab-On-Grade Edge Insulation PANTRY loft 0 50 ft2 ____ 1 0 0 1/1212021 3:52 PM EnergyGaugeAO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software . Page 3 of 7 V rAS-JfZ K p/t F1 $t�909-061,9 FORM R405-2017 INPUT SUMMARY GHEGKLIS I HEPUH I ROOF • / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 3144 ft2 0 ft2 Light N 0.2 No 0.9 No 20 22.62 ATTIC Area RBS IRCC V # Type Ventilation Vent Ratio (1 in) 1 Full attic Unvented 0 2902 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) MASTER BEDRO 0 Blown 278 ft2 0.1 Wood 2 Under Attic (Unvented) M TOILET 0 Blown 30 ft2 0.1. Wood 3 Under Attic (Unvented) M BATH 0 Blown 124 ft2 0.1 Wood 4 Under Attic (Unvented) M HALL 0 Blown 68 ft2 0.1 Wood 5 Under Attic (Unvented) HALF BATH 0 Blown 36 ft2 0.1 Wood 6 Under Attic (Unvented) M WIC 0 Blown 99 ft2 0.1 Wood 7 Under Attic (Unvented) CLST 2 0 Blown 18 ft2 0.1 Wood 8 Under Attic (Unvented) BEDROOM 2 0 Blown 177 ft2 0.1 Wood 9 Under Attic (Unvented) BEDROOM 3 0 Blown 1.82 ft2 0.1 Wood 10 Under Attic (Unvented) WIC 3 0 Blown 28 ft2 0.1 Wood 11 Under Attic (Unvented) WIC 4 0 Blown 28 ft2 0.1 Wood 12 Under Attic (Unvented) BEDROOM.4 0 Blown 169 ft2 0.1 Wood 13 Under Attic (Unvented) BEDROOM 5 0 Blown 238 ft2 0.1 Wood 14 Under Attic (Unvented) CLST 5 0 Blown 28 ft2 0.1 Wood 15 Under Attic (Unvented) SINKS 0 Blown 49 ft2 0.1 Wood 16 Under Attic (Unvented) TOILET RM 0 Blown 49 ft2 0.1 Wood 17 Under Attic (Unvented) HALLWAY 0 Blown 139 ft2 0.1 Wood 18 Under Attic (Unvented) KITCHEN 0 Blown 360 ft2 0.1 Wood 19 Under Attic (Unvented) FOYER 0 Blown 90 ft2 0.1 Wood 20 Under Attic (Unvented) FAMILY ROOM 0 Blown 460 ft2 0.1 Wood 21 Under Attic (Unvented) UTILITY RM 0 Blown 98 ft2 0.1 Wood 22 Under Attic (Unvented) ENTRY 0 Blown 104 ft2 0.1 Wood 23 Under Attic (Unvented) PANTRY 0 Blown 50 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 N Exterior Concrete Block - Ext InsMASTER BE 4.1 14 0 8 0 112.0. W 0 0 0.2 0 _ 2 W Exterior Concrete Block - Ext InsMASTER BE 4.1 20 0 8 0 160.0 ft2 0 0 0.2 0 _ 3 W Exterior Concrete Block - Ext Insul M TOILET 4.1 6 0 8 0 48.0 ft2 0 0 0.2 0 -4 W Exterior Concrete Block - Ext Insul M BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.2 0 _ 5 S Exterior Concrete Block - Ext Insul M W IC 4.1 11 0 8 0 88.0 ft2 0 0 0.2 0 6 W Exterior Concrete Block- Ext Insul M W IC 4.1 9 0 8 0 72.0 ft2 0 0 0.2 0 1/12/2021 3:52 PM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 V105TU, MetzI)1'*t0-V1V-CX#V8' 1=nPhA PAnr%-9n117 INPIIT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar. Below 10 Space WWI Type R-11all le Et In Et In AWa R-Vahle Emotion Ahsor r-rad"o 7 E Exterior Concrete Block - Ext Ins81EDROOM 2 4.1 5 0 8 0 40.0 ft2 0 0 0.2 0 8 S Exterior Concrete Block - Ext InsffiEDROOM 2 4.1 13 0 8 0 104.0 ft2 0 0 0.2 0 9 S Exterior Concrete Block - Ext InstSEDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.2 0 _ 10 S Exterior Concrete Block - Ext InsiBEDROOM 4 4.1 13 0 8 0 104.0 ft2 0 0 0.2 0 11 W Exterior Concrete Block - Ext InsLBEDROOM 4 4.1 6 0 8 0 48.0 ft2 0. 0 0.2 0 12 E Exterior Concrete Block - Ext InsMEDROOM 5 4.1 17 0 8 0 136.0 ft2 0 0 0.2 0 _ 13 S Exterior Concrete Block - Ext InsfflEDROOM 5 4.1 14 0 8 0 112.0 ft2 0 0 0.2 0 14 E Exterior Concrete Block - Ext Insul CLST 5 4.1 1 0 8 0 8.0 ft2 0 0 0.2 0 15 E Garage Frame - Wood CLST 5 11 1 0 8 0 8.0 ft2 0 0.1 0.2 0 16 E Garage Frame - Wood TOILET RM 11 7 0 8 0 56.0 ft2 0 0.1 0.2 0 _ 17 N Exterior Concrete Block - Ext Insul KITCHEN 4.1 18 0 12 0 216.0 ft2 0 0 0.2 0 _ 18 S Exterior Concrete Block - Ext Insul FOYER 4.1 5 0 8 0 40.0 ft2 0 0 0.2 0 19 N Exterior Concrete Block - Ext InSbIAMILY ROO 4.1 23 0 12 0 276.0 ft2 0 0 0.2 0 _ 20 E Garage Frame - Wood UTILITY RM 11 7 0 8 0 56.0 ft2 0 0.1 0.2 0 _ 21 N Exterior Concrete Block - Ext Insul ENTRY 4.1 4 0 8 0 32.0 ft2 0 0 0.2 0 - 22 E Garage Frame - Wood ENTRY 11 6 0 8 0 48.0 f12 0 0.1 0.2 0 23 N Exterior Concrete Block - Ext Insul PANTRY 4.1 10 0 8 0 80.0 ft2 0 0 0.2 0 24 E Garage Frame - Wood PANTRY 11 5 0 8 0 40.0 ft2 0 0.1 0.2 0 DOORS # Omt Door Type Space Storms U-Value Width Area Ft In FHeigh jn 1 S Insulated FOYER None .24 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 2 W 3 Metal Low-E Single Yes 0.65 0.25 N 4.0 ft2 2 ft 0 in 1 ft4 in None None 3 W 4 Metal. Low-E Single Yes 0.65 0.25 N 5.2 ft2 2 ft 0 in 1 ft 4 in None None 4 S 5 Metal Low-E Single Yes 0.65 0.25 N 10.0 ft2 2 ft0 in 1 ft4 in None None 5 S 8 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 10 ft 0 in 1 ft4 in None None 6 S 9 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 16 ft 0 in 1 ft 4 in None None 7 S 10 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 10 ft 0 in 1 ft 4 in None None 8 S 13 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 2 ft0 in 1 ft4 in None None 9 N 17 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft2 10 ft 0 in 1 ft4 in None None 10 N 19 Metal Low-E Single Yes 0.65 0.25 N 60.0 ft2 10 ft 0 in 1 ft 4 in None None 11 N 19 Metal Low-E Single Yes 0.65 0.3 N 48.0 ft2 10 ft 0 in 1 ft 4 in None None 1/12/2021 3:52 PM EnergyGaugeAO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 t-' 1 h}5TUAL- IVk- r'I I I :F ot)/&-z - C)La d 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 676 ft2 676 ft2 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000406 3091.2 169.59 318.39 .1332 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 2 Electric Strip Heat/ Electric Strip Heat/ None None COP:1 27 kBtu/hr 1 COP:1 17 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Central Unit/ Split Split Single SEER:16 29.4 kBtu/hr 882 cfm 0.8 1 Single SEER: 16 23.6 kBtu/hr 708 cfm 0.8 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / # ---- Supply---- Location R-Value Area -- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 Attic 6 140 ft2 Attic 6 130 ft2 Attic Attic 14 ft2 Default Leakage Garage (Default) c(Default) c 13 ft2 Default Leakage Garage (Default) c(Default) c 1 1 2 2 1/12/2021 3:52 PM EnergyGaugeAO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6.of 7 r 145-r-I:/z ti:wav-tIT -i:t 6ut�'c- C)dp/g FARM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES .Programable Thermostat: N Ceiling Fans - Cooling n Ing Jan Feb MMar Apr May Jun I Jul M Aug Aug Sep S Oct Oct Nov Nov Dec Dec [ p X Thermostat Schedule: HERS 2006 Reference Hours - Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (W EH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 - 68 MASS Mass Type Area Thickness Furniture Fraction Space Defauft(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 It 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 M HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 HALF BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8lbs/sq.ft. ft2 ft 0.3 WIC 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 5 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 5 Default(8 Ibs/sq.ft. ft2 ft 0.3 SINKS Default(8 Ibs/sq.ft. ft2 ft 0.3 TOILET RM Defauft(8 lbs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. 112 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 It 0.3 FOYER Default(8 Ibs/sq.ft. 1`12 It 0.3 FAMILY ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 UTILITY RM Default(8 Ibs/sq.ft. ft2 ft 0.3 ENTRY Default(8 Ibs/s .ft. ft2 ft 0.3 PANTRY 1/1 2t2021 3:52 PM EnergyGaugeAO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of.7 2017 • AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: KING RESIDENCE Builder Name: K S S INDUSTRIES Street: 6800 PEACOCK ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE, FL, 34987 Permit Number: Y Owner DANIELLE KING Jurisdiction: ST LUCIE COUNTY w Design Location: FL, Fort Pierce = COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITER General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be seated. Ceiiinglattic The air barrier In any dropped ceiling/soffit shall be aligned with the Insulation and any gaps in the air barrier shall be sealed. The insulation in any dropped ceiling/soffit Access openings, drop down stairs or knee wall doors to shall be aligned with the air barrier. unconditioned attic spaces shall be seated. Wags The junction of ftte foundation and sill plate shall be sealed. Cavities within comers and headers of frame wails The junction of the top plate and the top of exterior wags shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a themtal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shag be insulated. Floors The air barrier shalt be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space waits Exposed earth in rmvented crawl spaces shag be covered with a Where provided instead of floor insulation, insulation Class i vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Ste. peneirations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shag be sealed. Batts In narrow cavities shall be cut to fit, or narrow Narrow rarities cavities shag be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shag be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shag Recessed tight fixbues Installed in the butt W be seated to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shag be cut neatly to fit around wiring Plumbing in exterior walls. or insulation that on installation readily conforms to available space shall extend behind t ' and wiring. Shower/tub The air barrier installed at exterior wags adjacent to showers and FXterior wails adjacent to showers and tubs shag be on exterior wag tubs shag separate them from the showers and tubs. insulated. Electricai/phone box on The air barrier shag be installed behind electrical or communication exterior wags boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be seated to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shag only be sealed spnniaers u, a rrrmrner that for rncommenaea oy ine rirariurdciurer. GaullUng or paler adhesive sealants shall not be used to fill voids between fire sprinkler cover totes and wolfs or 0 TM ..- .....��...w ry .. wr.w..v. • v..�U mow .�, w. vv .,, awanyp, IYO AW I Y IG /!1 W1.17W IA W 1 V V-YUU. 5IM02011-04 AM E nergyGauga@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edilr'ort (2017) Compliant Software Page 1 of 1 �lr�cz t�tf�gaOl� O;f,7� g tom, 4 S 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* =100 RECEIVED FEB -- 2 2021 The lower the EnergyPerformance Index the more efficient the home. rnittluc Department � St Lucie County 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Detached or multiple -family 2. Detached b) Return ducts R 6.0 c) AHU location Garage 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 5 13. Cooling system: Capacity 53.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2902 d) Room unitIPTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.258 14. Heating system: Capacity 44.0 c) Area 7c. 289.2 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Stab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed Gode compliant features. Builder Signature: Date: ! /' 2 `� z Address of New Home: •68WPEACOCK ROAD City/FL Zip: PORT ST LUCIE FL 34987 1/12/2021 3:53:11 PM EnergyGauge@ USA 7.0.00 - Fla.Res2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 i"IIPaFE1L i r—V_t—tl I--"do`?—VCO1F� •2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: KING RESIDENCE Builder Name: K & S INDUSTRIES Street: (,Wo-m 10 PEACOCK ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE, FL, 34987 Permit Number: Y U Owner: DANIELLE KING Jurisdiction: ST LUCIE COUNTY w s Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA' INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not -be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation Narrow cavities readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind Pining and Wrin . Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover olates and walls or ceilinas. a. In addition, inspection of log walls shall be in accoroance wim the provisions of juG-400. 1/12/2021 3:53 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1