HomeMy WebLinkAboutEnergy Code,�>s ��er�►r��_ ©(,, 14�-5
-FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: KING RESIDENCE
Builder Name: K & S INDUSTRIES
Street: 66co •-68MPEACOCK ROAD
Permit Office: ST LUCIE COUNTY
City, State, Zip: PORT ST LUCIE, FL, 34987
Permit Number:
Owner: DANIELLE KING
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2052.0 sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Ext Insul, Exterior
R=4.1 1844.00 ft2
b. Frame - Wood, Adjacent
R=11.0 208.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 5
d. N/A
R= ft2
10. Ceiling Types (2902.0 sqft.)
Insulation Area
5. Is this a worst case? No
a Roof Deck (Unvented)
R=20.0 2902.00 ft2
6. Conditioned floor area above grade (ft2) 2902
b. N/A
R= ft2
c. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
11. Ducts
R ft2
7. W indoors (289.2 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 140
a. U-Factor: Sgl, U=0.65 241.20 ft2
b. Sup: Attic, Ret: Attic, AH: Garage
6 130
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65 48.00 ft2
12. Cooling systems
kBtu/hr Efficiency
a. Central Unit
29.4 SEER:16.00
SHGC: SHGC�.30
b. Central Unit
23.6 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
b. Electric Strip Heat
17.0 COP:1.00
Area Weighted Average Overhang Depth: 8.432 ft.
Area Weighted Average SHGC: 0.258
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (2902.0 sgft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 2902.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Area: 0.100 Total Proposed Modified Loads: 85.19
PASS
Glass/Floor
Total Baseline Loads: 85.39
I hereby certify that the plans and specifications covered by
Review of the plans and
't S�AT`p
this calculation ar
specifications covered by this
O�
Code.
calculation indicates compliance
with the Florida Energy Code.
ti rm� ��� •.; r3�s�.'� ,� O
PREPARED BY
Before construction is completed
DATE' 1-13-
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as d=ed'pliance
Florida Statutes.
CAD
with the Florida Energy e.
WE'D
OWNER/AGENT"-BUILDING
OFFICIAL:
DATE: P �31� Z
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
1/12/2021 3:52 PM EnergyGaugeAO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7
'Ili 4f—o96da—CYv
FORM R405-2017
INPUT SUMMARY UHI:L;KLI5I RtF'UR I
PROJECT
Title:
KING RESIDENCE
Bedrooms: 5
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2902
Lot #
Owner Name:
DANIELLE KING
Total Stories: 1
Block/Subdivision:
#of Units:
1
Worst Case: No
PlatBook:
6bo0
Builder Name:
K & S INDUSTRIES
Rotate Angle: 0
Street:
8WWPEACOCK ROAD
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
PORT ST LUCIE,
Family Type:
Detached
FL, 34987
New/E)asting:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating Design
Daily Temp
Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
AHU 1
1601
12808
2
AHU 2
1301
13688
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
MASTER BEDROO
278
2224 No
0
1
1
Yes
Yes
Yes
2
M TOILET
30
240 No
0
1
Yes
Yes
Yes
3
M BATH
124
992 No
0
1
Yes
Yes
Yes
4
M HALL
68
544 No
0
1
No
Yes
Yes
5
HALF BATH
36
288 No
0
1
No
Yes
Yes
6
M WIC
99
792 No
0
1
Yes
Yes
Yes
7
CLST 2
18
144 No
0
1
No
Yes
Yes
8
BEDROOM 2
177
1416 No
0
1
1
Yes
Yes
Yes
9
BEDROOM 3
182
1456 No
0
1
1
Yes
Yes
Yes
10
WIC 3
28
224 No
0
1
No
Yes
Yes
11
WIC 4
28
224 No
0
1
No
Yes
Yes
12
BEDROOM 4
169
1352 No
0
1
1
Yes
Yes
Yes
13
BEDROOM 5
238
1904 No
0
1
1
Yes
Yes
Yes
14
CLST 5
28
224 No
0
1
Yes
Yes
Yes
15
SINKS
49
392 No
0
1
No
Yes
Yes
16
TOILET RM
49
392 No
0
1
No
Yes
Yes
17
HALLWAY
139
1112 No
0
1
No
Yes
Yes
18
KITCHEN
360
4320 Yes
0
1
Yes
Yes
Yes
19
FOYER
90
720 No
0
1
Yes
Yes
Yes
20
FAMILY ROOM
460
5520 No
0
1
Yes
Yes
Yes
21
UTILITY RM
98
784 No
0
1
No
Yes
Yes
1/12/2021 3:52 PM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software . Page 2 of 7
i"1AS-1-ce 'Maj-)rr aura - 0(" i g
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SPACES
• Number Name
Area Volume
Kitchen Occupants
Bedrooms
InfilID Finished
Cooled
Heated
22 ENTRY
104 832
No 0
1 Yes
Yes
Yes
23 PANTRY
50 400
No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
MASTER BEDRO
34 ft
0
278 1t2
_--- 1
0
0
2 Slab -On -Grade Edge Insulation
M TOILET
6 ft
0
30 ft2
_--- 1
0
0
3 Slab -On -Grade Edge Insulation
M BATH
8 ft
0
124 ft2
___- 1
0
0
4 Slab -On -Grade Edge Insulation
M HALL
1 ft
0
68 ft2
-___ 1
0
0
5 Slab -On -Grade Edge Insulation
HALF BATH
1 ft
0
36 ft2
-_-- 1
0
0
6 Slab -On -Grade Edge Insulation
M WIC
20 ft
0
99 ft2
---- 1
0
0
7 Slab -On -Grade Edge Insulation
CLST 2
1 ft
0
18 ft2
___- 1
0
0
8 Slab -On -Grade Edge Insulation
BEDROOM 2
18 ft
0
177 ft2
_-__ 1.
0
0
9 Slab -On -Grade Edge Insulation
BEDROOM 3
13 ft
0
182 f12
---_ 1
0
0
10SIab-On-Grade Edge Insulation
WIC 3
1 ft
0
28 ft2
--__ 1
0
0
11SIab-On-Grade Edge Insulation
WIC 4
1 ft
0
28 ft2
___- 1
0
0
12SIab-On-Grade Edge Insulation
BEDROOM 4
19 ft
0
169 ft2
____ 1
0
0
13SIab-On-Grade Edge Insulation
BEDROOM 5
31 ft
0
238 ft2
_ - 1
0
0
14SIab-On-Grade Edge Insulation
CLST 5
i ft
0
28 ft2
____ 1
0
0
15SIab-On-Grade Edge Insulation
SINKS
1 It
0
49 ft2
_-__ 1
0
0
16SIab-On-Grade Edge Insulation
TOILET RM
1 ft
0
49 ft2
__-_ 1
0
0
17SIab-On-Grade Edge Insulation
HALLWAY
1 ft
0
139 ft2
---_ 1
0
0
18SIab-On-Grade Edge Insulation
KITCHEN
18 ft
0
360 ft2
--__ 1
0
0
19SIab-On-Grade Edge Insulation
FOYER
5 ft
0
90 ft2
____ 1
0
0
20SIab-On-Grade Edge Insulation
FAMILY ROOM
23 ft
0
460 ft2
_--- 1
0
0
21SIab-On-Grade Edge Insulation
UTILITY RM
1 ft
0
98 ft2
____ 1
0
0
22SIab-On-Grade Edge Insulation
ENTRY
4 ft
0
104 ft2
---- 1
0
0
23SIab-On-Grade Edge Insulation
PANTRY
loft
0
50 ft2
____ 1
0
0
1/1212021 3:52 PM EnergyGaugeAO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software . Page 3 of 7
V rAS-JfZ K p/t F1 $t�909-061,9
FORM R405-2017 INPUT SUMMARY GHEGKLIS I HEPUH I
ROOF
• /
Roof
Gable
Roof Rad
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Metal 3144 ft2
0 ft2
Light N
0.2
No 0.9
No 20
22.62
ATTIC
Area
RBS
IRCC
V
#
Type Ventilation
Vent Ratio (1 in)
1
Full attic Unvented
0
2902 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) MASTER BEDRO 0
Blown
278 ft2
0.1
Wood
2
Under Attic (Unvented) M TOILET
0
Blown
30 ft2
0.1.
Wood
3
Under Attic (Unvented) M BATH
0
Blown
124 ft2
0.1
Wood
4
Under Attic (Unvented) M HALL
0
Blown
68 ft2
0.1
Wood
5
Under Attic (Unvented) HALF BATH
0
Blown
36 ft2
0.1
Wood
6
Under Attic (Unvented) M WIC
0
Blown
99 ft2
0.1
Wood
7
Under Attic (Unvented) CLST 2
0
Blown
18 ft2
0.1
Wood
8
Under Attic (Unvented) BEDROOM 2
0
Blown
177 ft2
0.1
Wood
9
Under Attic (Unvented) BEDROOM 3
0
Blown
1.82 ft2
0.1
Wood
10
Under Attic (Unvented) WIC 3
0
Blown
28 ft2
0.1
Wood
11
Under Attic (Unvented) WIC 4
0
Blown
28 ft2
0.1
Wood
12
Under Attic (Unvented) BEDROOM.4
0
Blown
169 ft2
0.1
Wood
13
Under Attic (Unvented) BEDROOM 5
0
Blown
238 ft2
0.1
Wood
14
Under Attic (Unvented) CLST 5
0
Blown
28 ft2
0.1
Wood
15
Under Attic (Unvented) SINKS
0
Blown
49 ft2
0.1
Wood
16
Under Attic (Unvented) TOILET RM
0
Blown
49 ft2
0.1
Wood
17
Under Attic (Unvented) HALLWAY
0
Blown
139 ft2
0.1
Wood
18
Under Attic (Unvented) KITCHEN
0
Blown
360 ft2
0.1
Wood
19
Under Attic (Unvented) FOYER
0
Blown
90 ft2
0.1
Wood
20
Under Attic (Unvented) FAMILY ROOM
0
Blown
460 ft2
0.1
Wood
21
Under Attic (Unvented) UTILITY RM
0
Blown
98 ft2
0.1
Wood
22
Under Attic (Unvented) ENTRY
0
Blown
104 ft2
0.1
Wood
23
Under Attic (Unvented) PANTRY
0
Blown
50 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
Space
_ 1
N
Exterior Concrete Block - Ext InsMASTER BE
4.1 14
0 8 0
112.0. W
0
0 0.2
0
_ 2
W
Exterior Concrete Block - Ext InsMASTER BE
4.1 20
0 8 0
160.0 ft2
0
0 0.2
0
_ 3
W
Exterior Concrete Block - Ext Insul M TOILET
4.1 6
0 8 0
48.0 ft2
0
0 0.2
0
-4
W
Exterior Concrete Block - Ext Insul M BATH
4.1 8
0 8 0
64.0 ft2
0
0 0.2
0
_ 5
S
Exterior Concrete Block - Ext Insul M W IC
4.1 11
0 8 0
88.0 ft2
0
0 0.2
0
6
W
Exterior Concrete Block- Ext Insul M W IC
4.1 9
0 8 0
72.0 ft2
0
0 0.2
0
1/12/2021 3:52 PM EnergyGaugeA® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
V105TU, MetzI)1'*t0-V1V-CX#V8'
1=nPhA PAnr%-9n117 INPIIT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar.
Below
10
Space
WWI Type
R-11all le
Et
In
Et
In
AWa
R-Vahle
Emotion Ahsor
r-rad"o
7
E
Exterior
Concrete Block - Ext Ins81EDROOM 2
4.1
5
0
8
0
40.0 ft2
0
0
0.2
0
8
S
Exterior
Concrete Block - Ext InsffiEDROOM 2
4.1
13
0
8
0
104.0 ft2
0
0
0.2
0
9
S
Exterior
Concrete Block - Ext InstSEDROOM 3
4.1
13
0
8
0
104.0 ft2
0
0
0.2
0
_ 10
S
Exterior
Concrete Block - Ext InsiBEDROOM 4
4.1
13
0
8
0
104.0 ft2
0
0
0.2
0
11
W
Exterior
Concrete Block - Ext InsLBEDROOM 4
4.1
6
0
8
0
48.0 ft2
0.
0
0.2
0
12
E
Exterior
Concrete Block - Ext InsMEDROOM 5
4.1
17
0
8
0
136.0 ft2
0
0
0.2
0
_ 13
S
Exterior
Concrete Block - Ext InsfflEDROOM 5
4.1
14
0
8
0
112.0 ft2
0
0
0.2
0
14
E
Exterior
Concrete Block - Ext Insul CLST 5
4.1
1
0
8
0
8.0 ft2
0
0
0.2
0
15
E
Garage
Frame - Wood CLST 5
11
1
0
8
0
8.0 ft2
0
0.1
0.2
0
16
E
Garage
Frame - Wood TOILET RM
11
7
0
8
0
56.0 ft2
0
0.1
0.2
0
_ 17
N
Exterior
Concrete Block - Ext Insul KITCHEN
4.1
18
0
12
0
216.0 ft2
0
0
0.2
0
_ 18
S
Exterior
Concrete Block - Ext Insul FOYER
4.1
5
0
8
0
40.0 ft2
0
0
0.2
0
19
N
Exterior
Concrete Block - Ext InSbIAMILY ROO
4.1
23
0
12
0
276.0 ft2
0
0
0.2
0
_ 20
E
Garage
Frame - Wood UTILITY RM
11
7
0
8
0
56.0 ft2
0
0.1
0.2
0
_ 21
N
Exterior
Concrete Block - Ext Insul ENTRY
4.1
4
0
8
0
32.0 ft2
0
0
0.2
0
- 22
E
Garage
Frame - Wood ENTRY
11
6
0
8
0
48.0 f12
0
0.1
0.2
0
23
N
Exterior
Concrete Block - Ext Insul PANTRY
4.1
10
0
8
0
80.0 ft2
0
0
0.2
0
24
E
Garage
Frame - Wood PANTRY
11
5
0
8
0
40.0 ft2
0
0.1
0.2
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Area
Ft
In
FHeigh jn
1
S
Insulated FOYER
None
.24
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed
orientation.
wall
Overhang
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N 1
Metal Low-E Single Yes
0.65
0.25
N
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
2
W 3
Metal Low-E Single Yes
0.65
0.25
N
4.0 ft2
2 ft 0 in
1 ft4 in
None
None
3
W 4
Metal. Low-E Single Yes
0.65
0.25
N
5.2 ft2
2 ft 0 in
1 ft 4 in
None
None
4
S 5
Metal Low-E Single Yes
0.65
0.25
N
10.0 ft2
2 ft0 in
1 ft4 in
None
None
5
S 8
Metal Low-E Single Yes
0.65
0.25
N
30.0 ft2
10 ft 0 in
1 ft4 in
None
None
6
S 9
Metal Low-E Single Yes
0.65
0.25
N
30.0 ft2
16 ft 0 in
1 ft 4 in
None
None
7
S 10
Metal Low-E Single Yes
0.65
0.25
N
30.0 ft2
10 ft 0 in
1 ft 4 in
None
None
8
S 13
Metal Low-E Single Yes
0.65
0.25
N
30.0 ft2
2 ft0 in
1 ft4 in
None
None
9
N 17
Metal Low-E Single Yes
0.65
0.25
N
12.0 ft2
10 ft 0 in
1 ft4 in
None
None
10
N 19
Metal Low-E Single Yes
0.65
0.25
N
60.0 ft2
10 ft 0 in
1 ft 4 in
None
None
11
N 19
Metal Low-E Single Yes
0.65
0.3
N
48.0 ft2
10 ft 0 in
1 ft 4 in
None
None
1/12/2021 3:52 PM EnergyGaugeAO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7
t-' 1 h}5TUAL- IVk- r'I I I :F ot)/&-z - C)La d 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
676 ft2
676 ft2
26 ft 8 ft 11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.000406
3091.2 169.59 318.39 .1332 7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1
2
Electric Strip Heat/
Electric Strip Heat/
None
None
COP:1 27 kBtu/hr 1
COP:1 17 kBtu/hr 2
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
2
Central Unit/
Central Unit/
Split
Split
Single SEER:16 29.4 kBtu/hr 882 cfm 0.8 1
Single SEER: 16 23.6 kBtu/hr 708 cfm 0.8 2
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.98 50 gal 55.1 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert #
Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ft2
DUCTS
/
#
---- Supply----
Location R-Value Area
-- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1
2
Attic 6 140 ft2
Attic 6 130 ft2
Attic
Attic
14 ft2 Default Leakage Garage (Default) c(Default) c
13 ft2 Default Leakage Garage (Default) c(Default) c
1 1
2 2
1/12/2021 3:52 PM EnergyGaugeAO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6.of 7
r 145-r-I:/z ti:wav-tIT -i:t 6ut�'c- C)dp/g
FARM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
.Programable Thermostat:
N
Ceiling Fans -
Cooling
n Ing Jan
Feb
MMar
Apr
May
Jun
I
Jul
M Aug
Aug
Sep
S
Oct
Oct
Nov
Nov
Dec
Dec
[
p
X
Thermostat Schedule: HERS 2006 Reference
Hours
-
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (W EH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating (WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (W EH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68 -
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Defauft(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M TOILET
Default(8 Ibs/sq.ft.
ft2
It
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALF BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8lbs/sq.ft.
ft2
ft
0.3
WIC 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 5
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 5
Default(8 Ibs/sq.ft.
ft2
ft
0.3
SINKS
Default(8 Ibs/sq.ft.
ft2
ft
0.3
TOILET RM
Defauft(8 lbs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
112
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
It
0.3
FOYER
Default(8 Ibs/sq.ft.
1`12
It
0.3
FAMILY ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
UTILITY RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
ENTRY
Default(8 Ibs/s .ft.
ft2
ft
0.3
PANTRY
1/1 2t2021 3:52 PM EnergyGaugeAO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of.7
2017 • AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: KING RESIDENCE Builder Name: K S S INDUSTRIES
Street: 6800 PEACOCK ROAD Permit Office: ST LUCIE COUNTY
City, State, Zip: PORT ST LUCIE, FL, 34987 Permit Number:
Y
Owner DANIELLE KING Jurisdiction: ST LUCIE COUNTY
w
Design Location: FL, Fort Pierce
=
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITER
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be seated.
Ceiiinglattic
The air barrier In any dropped ceiling/soffit shall be aligned with the
Insulation and any gaps in the air barrier shall be sealed.
The insulation in any dropped ceiling/soffit
Access openings, drop down stairs or knee wall doors to
shall be aligned with the air barrier.
unconditioned attic spaces shall be seated.
Wags
The junction of ftte foundation and sill plate shall be sealed.
Cavities within comers and headers of frame wails
The junction of the top plate and the top of exterior wags shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a themtal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shag be insulated.
Floors
The air barrier shalt be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crawl space waits
Exposed earth in rmvented crawl spaces shag be covered with a
Where provided instead of floor insulation, insulation
Class i vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Ste. peneirations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shag be sealed.
Batts In narrow cavities shall be cut to fit, or narrow
Narrow rarities
cavities shag be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shag be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shag
Recessed tight fixbues Installed in the butt W
be seated to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shag be cut neatly to fit around wiring
Plumbing in exterior walls. or insulation that on
installation readily conforms to available space shall
extend behind t ' and wiring.
Shower/tub
The air barrier installed at exterior wags adjacent to showers and
FXterior wails adjacent to showers and tubs shag be
on exterior wag
tubs shag separate them from the showers and tubs.
insulated.
Electricai/phone box on
The air barrier shag be installed behind electrical or communication
exterior wags
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
seated to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shag only be sealed
spnniaers
u, a rrrmrner that for rncommenaea oy ine rirariurdciurer. GaullUng or paler
adhesive sealants shall not be used to fill voids between fire sprinkler
cover totes and wolfs or 0 TM
..- .....��...w ry .. wr.w..v. • v..�U mow .�, w. vv .,, awanyp, IYO AW I Y IG /!1 W1.17W IA W 1 V V-YUU.
5IM02011-04 AM E nergyGauga@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edilr'ort (2017) Compliant Software Page 1 of 1
�lr�cz t�tf�gaOl� O;f,7� g
tom, 4 S
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* =100
RECEIVED
FEB -- 2 2021
The lower the EnergyPerformance Index the more efficient the home. rnittluc Department
� St Lucie County
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Detached or multiple -family
2. Detached
b) Return ducts R
6.0
c) AHU location
Garage
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 5
13. Cooling system: Capacity 53.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 2902
d) Room unitIPTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.650
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.258
14. Heating system: Capacity
44.0
c) Area
7c. 289.2
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Stab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.98
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2. 4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131. 11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a. 0.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
f) Programmable thermostat
No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed Gode compliant features.
Builder Signature: Date: ! /' 2 `� z
Address of New Home: •68WPEACOCK ROAD City/FL Zip: PORT ST LUCIE FL 34987
1/12/2021 3:53:11 PM EnergyGauge@ USA 7.0.00 - Fla.Res2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
i"IIPaFE1L i r—V_t—tl I--"do`?—VCO1F�
•2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: KING RESIDENCE Builder Name: K & S INDUSTRIES
Street: (,Wo-m 10 PEACOCK ROAD Permit Office: ST LUCIE COUNTY
City, State, Zip: PORT ST LUCIE, FL, 34987 Permit Number:
Y
U
Owner: DANIELLE KING Jurisdiction: ST LUCIE COUNTY
w
s
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA'
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not -be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on installation
Narrow cavities
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring an
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind Pining and Wrin .
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover olates and walls or ceilinas.
a. In addition, inspection of log walls shall be in accoroance wim the provisions of juG-400.
1/12/2021 3:53 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1