Loading...
HomeMy WebLinkAboutProject InformationProject ProjSumma Job: -�- wrightsoft° AHU � e: May A 2020 QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE, FL 34946 Phone: 772466-6799 Fmc 7724884798 EMM QUICKCALCS@AOL.COM Project• • For. DANIELLE KING, K & S INDUSTRIES 6800 PEACOCK ROAD, PORT ST LUCIE, FL 34987 Notes Design Information Weather Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18279 Btuh Structure 15686 Btuh Ducts 4401 Btuh Ducts 6208 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Stuh (none) (none) Hurhidification 0 Btuh Blower 0 Btuh Eq ipment 8 uthi load 22680 Use manufacturers data n Ratelswingg multiplier Equipment load 0.95 Infiltration sensible 20800 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3421 Btuh Ducts 1671 Btuh Central vent (0 cfm) 0 Btuh Heating cooling (none) Area (ft� 160'I 1IN Equipment latent load 5092 Btuh Volume (W) 12808 12808 Air changes/hour 0.43 0.22 Equipment Total Load (Sen+tat) 25891 Btuh Equiv. AVF (cfm) 92 46 Req. total capacity at 0.70 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond CA16NW03000GOA0 AHRI ref Coil FX4DNF037L AHRI ref 9201884 Efficiency 100 EFF Efficiency 13.5 EER, 16 SEER Heating input 6.1 kW Sensible cooling 20580 Btuh Heating output 20707 Btuh Latent cooling 8820 Btuh Temperature rise 19 OF Total cooling 29400 Btuh Actual air flow 980 cfm Actual air flow 980 cfm Air flow factor 0.043 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat toad sensible heat ratio 0.81 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. i� -Ff&- wrigh ffio�f'! 2020-May-0810.3201 ^ � Right-Suite®U MM81201919.0.08 RStA8101 Page 1 A E 1DocwmetsMightsoft WACIKING RESIDENCE.rup Cale = MJ8 Front Doorboes: S Project Summary,Job: - - wrightsoft° AH 2 Date: r e: May os, 2020 QUICK CALCS, INC. 317 ST LUCIE LAW- FORT PIERCE, FL 34946 Phone: 772.46W99 Fmc 772488.6798 Email: QUICKCALCS@AOLCOM Project Information For � PEEAACOCK 4W, PORTSTILUCIE, FL 34987 Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF DDes gnn TrangDe 155 OF Relative ive humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 10284 Btuh Structure 13396 Btuh Ducts 3108 Btuh Ducts 4504 Btuh Central vent (0 cfm) 0 Stuh Central vent (0 cfm) 0 Btuh (none) (none) Humid cation 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 13392 Btuh Use manufacture's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 17005 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2531 Btuh Ducts 1216 Btuh Central vent (0 cfm) 0 Btuh Area Heating Coolin (,none) (ft) 1301 1301 Equipment latent load 3747 Btuh Volume (ft3) 13688 13688 Air chan&e Jhour 0.22 0.11 Equipment Total Load (Sen+Lat) 20752 Btuh Equiv. AVF (cfm) 49 25 Req. total capacity at 0.70 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER Model Cond CA16NW02400GOA0 AHRI ref Coil F)(4DNF025L AHRI ref 9201324 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 3.4 kW Sensible cooling 16520 Btuh Heating output 11667 Btuh Latent cooling 7080 Btuh Temperature rise 13 OF Total cooling 23600 Btuh Actual air flow 787 cfm Actual air flow 787 cfm Air flow factor 0.059 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -FI&- wrlghtsofC- 2020-May-0810.32:01 Right-Wde®tkMmal 21919.0.08 RSU08101 Page 2 ' � E:1DomnnetslWrightsoR WACU9NG RESIDENCE.rup Cffia - MJ8 Front Dow bm: S -Fb- wrightsoft Right-J® Worksheet Job: AHU 7 Date: May 08, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LAME, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fax M-466.67M Ems➢: OUICKCALCSQAOLCOM 1 Room narne AHu 1 MASTER BEDROOM 2 Eked wa0 150.0 ft 34.0 ft 3 Room tteigttt 8.0 It &0 ft heaUcool 4 Roan dimensions 1.0 x 278.0 ft 5 Room ama 1601.0 ft2 278.0 ftZ Ty cashEft uaebm Or HTM A► a Pn IAad Area M Load Dunbar (Bttl>tfft�'F) Pm or perimeter (ft) (Bttdt) or pethder (ft) (Blob) Heat Cod Gross N/P1S Heat Cod Gross PUP/S Heat Cool 6 Nh 13144acs 0.143 n 4.00 219 112 82 328 179 112 82 .328 179 2 gli-a tg, cir Iowa 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 2gla2irg, drbawe 0.650 n 18.20 14.99 30 0 646 450 - 30 0 . _ 546 450 20mft drlowwe 0.650 n 0.00 1100 0 0 0 0 0 0. 0 0 1 i w 13AAm (1143 a 4.00 219 184 184 737 403 0 0 0 0 13A40 s 0.143 s 4.00 219 512 382 1530 836 . 0 0 0 0 2111; f % drhwe 0.650 s 1820 . -14.99 10 10 182 150 . 0 0 0 0 b 2 gWng, cir w-e 0.650 s 18.20 14.99 120 120 2184 1799 0 0 0 0 1100 0.390 s 0.00 0.00 10.. 0 0.. .0 0 0 0 0 V� 13AAocs 0.143 w 4.00 219 392 383 1533 838 160 160 641 350 2 gfaarg, cir bw-e 0.6m w 18.20 33.77 4 0 73 135 0 0 0 0 2 slezrim cir bore M650 w 18.20 28.57 5 1 95 149 0 0 0 0. C 16X190W 0: - 1.59 1.37 1601 1601 2538 ' . 2190 . 278 278 441.. 380 F 22A4ph 1.358 - 38.02 0.00 1601 150 5704 0 278 34 1293 0 6 c)AED wcumicn 0 -39 Envelops loss/gain 15449 7128 3249 1321 12 a) Infilhation 2830 758 641 172 b) Room ventilation 01 0 0 0 13 trderrel gains: Occupants 0 230 0 0 Applianoesiather 78M 2600 Subtotal Pines 6 to 13) 18279 16688 3890 4093 Less e#mud bad 0 0 0 0 Redistribution 0 0 12 10 14 Subtotal 18279 15686 3902 4102 15 Dud bads 24% 40'/0 4401 6208 24% 40% 939 1624 Total room load 22680 21894 4841 5725 Air n�ulred (cfm) 96D 980 209 258 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. . -rid- Wr'19 *Saik' 2020-May-081 : g91 Rk t-GuiteO tWwersa1201919.0.08 RSLW101 E1Doeunviets\Wdghtsog WACIKING RESIDENCF-rup Cale = MJ8 Frond Door faces: S -- wrightsoft° Right-J® Worksheet Job: AHU 1 Date: May 08, 2020 Ely, QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-4664M Ema: aUICKCALCS@AOLCOM 1 Roorn row M 7OB.Er M BATH waH 6.0 ft &0 ft 3 Ra�om� heV9 0.0 ft tMucooi &0 ft heaf/cod 4 Room dmensiwts 5.0 x 6.0 ft 1.0 x 124.0 ft 5 Room area 30.0 ttz 124.0 W Ty Co wh dion Uatahre Or NTM Area (ft5 toad Area (ft-) Load rtllrnber (Btttllft�`F1 (etulyft�) or Perimeter (ft) (Btuh) or Perimeter (ft) (stub) Had I Cool Gross NIP/S Had Cod Gross WKS Neat Cool 6 13A ocs 0.143 n 4,00 219 0 0 0 0 0 0. 0 0 I G 2 glazing, cir Im" 0.GW n 0.00 0.00 0 0 0_ 0 0 01. 0 0 2gbzira cirbw-e 0.69D n 18.20 .14.99 0 0 0 0 0 .0 0 0 +;.�G 2gim ng, chb" 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 t 1 W 13AAocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 13A4ocs 0.143 s 4.00 7-19 0 0 .0 .0 0 0. 0 0 2 gla&a dr bh-e 0.650 s AM 14.99 o' 0 0 0 0 0 0 0 2 glazing, dr &N" 0.650 s 1&20 14.99 0 0 0 0 -0 0 0 0 11DO 0.390 s 0.00 0.00 0 0 0 0 0 0 0 '0 Val 13A a s 0.143 w 4.00 2.19 48 44 176 96 64 59 235 129 i--(' 2 gMn_q dr b*e 0.650 w 1820 33.77 4 0 73 135 0 0 0 0 L-C 2 Samna dr bw-e 0.650 w 1&20 28.57 0 0 0 0 5 1 95 149 C 16X19ow 0.408 `- 1.59 1.37 `. 30 30 48. 41 124 124, 197 170 F 22A4Dh 1.358 - 38.02 0.00 30 6 228 0 124 8 304 0 6 c)AED elazesion 54 84 Bwelops bss/gain 525 325 831 530 12 a) k ilhaticn 113 30 151 40 b) Room w4gaUm 0 0 0 0 13 Intemat gains: Occupaids @ 230 0 0 0 0 App6artwslother 0 I Soo Subtotal (fines 6 to 13) 6381 355 982 871 Less a Real load 0 0 0 0 Redtsr bigon 0 0 31 26 14 Subtotal 638 356 1013 897 15 Duct btu 24% 409/0 154 141 24% 40% 244 355 Total room load 791 497 1 1256 1252 Air r-WWd (efm) 34 'YL 6d 66 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -Fii- !=1S etsoTt- 2M May-0810.32:01 A&k RIgMSulte® lMiversa1201919.0.08 RSU08101 mPage 2 EADocunstsMigtdsott WACIIGNG RESIDENCErup Cole M.B Fiwd Door races: S -t - wrightsoft Right-J® Worksheet Job: AHU 1 Date. May 08, 2020 sr. QUICK CALCS, INC. 317 ST LUCIE LAW, FORT PIERCE, FL 34946 Phone: 77246SW99 Fax 772.4664M Email: QUICKCALCS@AOLCOM 1 Roan name M HALL HALF BAM oft Oft 3 Room hhWO &0 ft hea cool &0 ft heaHcool 4 5 Room dimensions Room area 1.0 x 68.0 ft 68.0 fi= 9.0 x 4.0 ft 36.0 ftl Ty number ( F) Or (f#tdllfizj Ama (ft-) orpemneter (ft) Load @W) (fF) Area imeter (ft) PerHTM Load W) Heat Cod Gross NIP/S Heat Coat Gross IN/PIS Heat I Coo( 6 '134-0ccs. 2 glazing, dr tow a 2 *Gang, ctr bx-e- 11143 0.650 0.650 n n n' 4,00 0.00 16.20 - 219 .. 0.00 14.99 ' 0 0 0 0, 0 0 0- 0 0 01 0 0 0 0'. 0 0 0 0 0 0 0 0 0 0 w 11 2gtaang drbwe 13A!tacs 0.650 0.143 n a 0.00 4.00 0.00 2.19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13AA= 2gl' 1- cirtow-e 0.143 Q650 a a 4.00 11120 2.19 -- 14.99' 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazft dr tows 0.650 s 18.20 :. 14.99 0 0 0 0 0 0 0 0 11Do 13A�4ocs 0.390 0.143 .s w 0.00 4.00 6.00 2-19 0 0 0 0 0 0 0 0 0, 0 0 0 0 0 0 0 �l F-�-G 2 dazing, dr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 T-G C 2 dam ctr rawer 16 gAw d 0.650 Q408 w . - 18.20 ' 1.59 7557 . 1.37 0 ' 0 .68 0 . " . 108 0 93 0 . 36 0 36 0 67 0 49 F 22A4ph 1.358 - 38.02 0.00 fib 0 0 0 36 0. 0 0 6 c)AED exxlasion -1 -4 En-Iope kWgain 108 92 57 45 12 a) InfiBration 0 0 0 0 b) Room %srrtation 0 0 0 0 13 1ltemal gains: Ocaipards Q 230 0 0 0 0 AppCances edw 0 400 Subtotal (fines 6 to 13) 108 92 57 445 Less e>demel load 0 0 0 0 Less bansfer 0 0 0 0 Redstnlxrtion -108 -W 63 54 14 Subtotal 0. 0 120 499 15 Duct loads 249/0 40%1 0 0 24% 40% 29 197 Total roan load Air regtdred (effn) 0 a 0 O 149 6 696 31 _ Calculations ammyed bvACCA to meet all requirements of Manual J 8th Ed. -rid- wrlyh�soT!^ Aft RlghtSuite® UnlYemsal201919.0 08 RSU08101 2020-May-08 10,32:01 E:1Dooutnnets%Wtightsoft HVAC110NG RESIDENCE.rup Cak = MJB Fwnt Doorfaces: S Page 3 - - wrightsoft Right-JO Worksheet Job: AHU 1 Date: May 08, 2020 QUICK CALCS, INC. Byr 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 7721466.67 Emafl: QUICKCALCS@AOLCOM 1 Room rwm M WIC CLST 2 2 Evosed wall 20.0 ft 0 R 3 Room he ght 8.0 ft heat/cool 8.0 ft hmUmd 4 Room danensians 11.0 x 9.0 ft 9.0 x 2.0 ft 5 Roan area 99.0 ft2 1&0 ft2 Ty Cr HTM PM Load Ama (ft) Load mgnber @kdiWF) {BtrdUft2) orpedmeeter (ft) (Btuh) or plfimeter (ft) (Btuh) H Cod Gross N!P/S Heat Cool Gross NIP/S Heat Cool 6 13J44ocs 0.143 n 4.00 219 0 0 0 0 0 0- 0 0 2 glazing, dr bt-e 0.650 n 0.00 0.00 0 0 A. 0 0 0 0 0 2 glazing, dr b" 0.650 n 18.20 " 14.99 0 0 0-. 0 0 0 0 0 2gtaang; drbw-e 0.650 n 0.00 0.00 0 0 0 0 0: 0 0 0 11 W 13A�4acs M143 a 4.00 219 0 0 0 0 0 0 0 0 lq! 13A-0oes 0.143 s - 4.00 219 88 78 312 171 0 0 0 0 2 g adn dr tawe 0.650 s 18.20 , 14.99 .. 10 10 182 150 0 0 ' 0 '0 2glazirg drkm-e 0.650 s- 18.20 14.99 0 0 0 0 0. 0 0 0 11DO , 6.390 : s. 0.00 0.00 0 0 0 0 0 0`. 0 0 Val 13A4ocs 0.143 w 4.00 7-19 72 72 288 158 0 0 0 0 f---G 2 gtazirg, dr bv-e 0.650 w 1820 33.77 0 0 0 0 0 0 0 0 �--G 2 qtaznst dr b" 0.5m w 18.20 28L67 0 0. 0 0 0 0 0 0 C 16X1904 Q408 - 1.59 1.37... 99 . 99 157 135.. 1 - .18. 29 25 F 22Mph 1.358 - 38.02 0.00 99 20 760 0 18 0 0 0 6 c)A®emuslon 40 0 ErwdoW toss/gain 1700 6W 29 24 12 a) k0ration 377 101 0 0 b) Room ventilation 0 0 0 0 13 Intend gains: Occupants @ 230 0 0 0 0 AppCr,mcedother 300 1 0 Subtotal (rules 6 to 13) 2077 1005 29 24 Less external bad 0 0 0 0 Less transfer 0 0 0 0 Redstrblion 0 0 29 24 14 Subtatal 20" 1005 0 0 15 Duct bads 24% 40%1 500 398 24% 40% 0 0 Total roan load 2578 1403 0 0 Air regd W (cfm) 111 63 0 0 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. - - wrtght�s 2020-May-0810:32.01 .&P. RightSuReG UnWmal 201919.0.08 RSU08101 Page 4 EnDocumets\Wrlghtsoft HVACWNG RESIDENCE rup Calc = MJB Front Door laces: S . + wrightsot Right-J® Worksheet AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466.6796 Email: QUICKCALCSQAOLCOM Job: Date: May 08.2020 By: 1 Room name BEDROOM 2 BEDROOM 3 2 Exposed wall 18.0 ft 13.0 ft 3 Room heigtd 8.0 ft heal/cool 8.0 ft heat/cool 4 Room trmenstons 1.0 x 177.0 ft 13.0 x 14.0 ft 5 Room area 177.0 ft= 182.0 ft' Ty ConM an Or Area (ft-) Load Area (fP) Load umb number ft" _F) IF) or WkWer (ft) @M) or Perimeter (ft) PM) Heat Coot Gross IWKS Had Cod Gross lWP/S Heat Cod 6' 13A4ocs M143 n 4.00 . 219 0 0 0 0 0 0 0 0 p G' 2 O&M dr bw•e 0.650 n 0.00 Q00 0 0 0 0 0 0 0 0 20mft ctrbw-e 0.650 n 182D 14.99 0 0 0 0 0 0 0 0 r�----tG' 2 grazing, dr ikWe 0.650 n 0.00 0.00 0 0 0 0 0 0- 0 0 1 i W 13Ar4ocs 0.143 a 4.00 2.19 40 40 160 88 0 0 0 0 13A4ocs 0.143 s 4.00 2.19 104 74 295 162 104 74 295 162 2 gl: I g ctr lo" 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 gamin dr bw-e 0.650 s 18.20 14.99 30 - 30 546 450 30 30 546 450 11DO 0.390 a 0.00 0:00 - 0 0 0 0 0 0 0 0 1l� 13A�4ocs 0.143 w 4.00 219 0 0 0 0 0 0 0 0 1--(' =s 2 giazitg, dr bw-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 dazirq, cU lowe 0.650 w 18.20 28.57 0 0 0 0 0 0 0 0 C 1W90md 0.408 - 1.59 1.37 ' - 177 177 281 242 182 182 289 249 F 22A4ph 1.358 - 38.02 0.00 177 18 884 0 182 13 4W 0 6 c)AED exursion 47 -18 Envelope loss/gain 1968 924 1625 843 12 a) Infiltration 340 91 245 66 b) Room ventilation 0 0 0 0 13 Irdemal gains: Occupants Q 230 0 0 0 0 Appliances/other 800 1 1000 Subtaw (tines 6 to 13) 2307 1815 1870 1908 Less erdemal bad 0 0 0 0 Less transfer 0 0 0 0 Rec5 Wbutlon 31 27 0 0 14 Subtotal 2338 1842 1870 1908 15 Dud bads 24%1 405/6 563 729 24% 40% 450 755 Total room load 2901 2571 = 2664 Ak nnired (cfm) 1 11 100 119 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. wrlgFr boR� RigMS2020-May-08 10:3201uita® Universal 201919.0.08 RSU08101 Page 5 EADocunnetslWrightsoft WACIKING RESIDENCE.rup Calc = MJ8 Front Door faces: S -►- wrightsofC Right J® Worksheet Job: AHU 7 Date: May 08, 2020 BY, QUICK CALCS, INC. 317 ST LUCIE LAW- FORT PIERCE, FL 34946 Phone: 772466.6799 Fax 772-4664M Emaff: QUICKCALCS@AOLCOM 1 Rolm rom WIC 3 wlc 4 2 O ft 0 ft 3 &0 ft heaucool 8.0 ft heaticool 4 4.0 x 7.0 ft 4.0 x 7.0 ft 5 Roam ales 28.0 ft= 28.0 ftz Ty wn or mmiber ( -'F) (Btuhfft� Periimeter (ft) ( ) Perimeter (ft) ( ) Heat Cool Gross WIS Heat Cool Gross NIPIS Had Cool 6 13144ocs 0.143 . n 4,00 . 219 0 0 0- 0 0°. 0 0. 0 2 giatlr� cir b a 0.650 n 0.00 0.00 0 0. 0 0- 0.0 0 -0 20=131 g, ctr bare 0.6W . n 18.20 14.99- 0' 0 0 0 0 0 0 0 2g�itlg drlcxrs 0.650 n 0.00 M00 0 0 0 0 0 0 0 11 W 13A-0acs 11143 a 4.00 219 0 0 0 0 0 0 0 0 13AAocs 0.143 s 4.00 2.19 0. 0 0 0 0 0 0 0 2 g9aung do low a 0.690 s 18.20 14.99 0 0 0 0 0 -0 0 2 glaz)ng, dr bws 0.650 s 18.20 14.99 0- 0- 0 0 0 0 0 0 11DO 0.390 s- 0.00 0 00 0 0 0 0. 0 U 0 0 V� 13A 4ocs 0.143 w 4.00 219 0 0 0 0 0 0 0 I-C' 2 gY83ng, dr low-e 0.6m w AM 33.77 0 0 0 0 0 0 0 0 T-C a dawn cir lows 0.650 w 18.2D 26.57 0 0 0 -44, 0 0 0 0 0 C 16%190nd 0A08 .- :.1.59 ; .: 1.37 - -28 28, 38 . - 28 - 28 44 36 F 2244ph 1.358 - 38.02 0.00 28 0 0 0 28 0 0 0 6 c)AM elxur W 11 .4 Fs -elope, bswgain 1 1 441 ml 1 1 441 35 12 a) k0tration 0 0 0 0 b) Room ventWon 0 0 0 0 13 Internal gams: Occupants Qa 230 0 0 0 ' 0 Apptlatsceslothw 330 350 Subtotal (Ones 6 to 13) 44 385 44 385 Less external load 0 0 0 0 U SS transfer 0 0 0 0 R�tsibutlm 0 0 0 0 14 Subtotal 44 385 44 385 15 Duct 24% 40% 11 152 24% 40% 11 152 TotAir 24 52 5324T rregr�uedl(Win) Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .� -Fi+-„' �g�!�� 202o-May-0810:32:01 RIghtSufte& Universal 201919.0.08 RSU08101 Page 6 E:tDocumnets%Wrightsoft HVACIIGNS RESIDEICE.rup Cato = MJ8 Front Door faces: S -�- wrightsoft' Right-J® Worksheet Job: AHU 1 Date: May 08, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LAW- FORT PIERCE. FL 34946 Phone: M-465.6799 Fax 772-4664796 Eme9: GUICKCALCS@AOLCOM 1 Rom nam BEDROOM 4 BEDROOM 5 2 E�osed vueG 19.0 ft 31.0 ft 3 Roan height 8:0 ft heatlaml 8.0 ft heWax>l 4 Room dlnerWm s 1&0 x 13.0 ft 14.0 x 17.0 ft 5 Roan area 169.0 ft2 238.0 ft2 Ty Cm*uction U-value Or HTM Area (ft2) load Area (ft2) Load number (Btty" or Perimeter (ft) (Btuh) or pemneter (ft) (Btuh) Heat Cool Gross NlP/S Heat Coot Gross WP1S Heat C001 6 13AAGOS 0.143 .n 4.00 2:19 0 0 0 0 0 0" 0 0 2 glazing cir b" 0.6m n 0.00 - 0.00 0 0 0 0 0 0 0 0 2glaz6g driaw-e 0.650 n. 18f20 14.99 0 0. 0 0 0 0 0 0 2glaang drbwe 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 11 w 13A4ocs M143 a 4.00 Z19 0 0 0 0 136 136 545 298 0.143 a 4.00 Z19 104 74 296 162 112 - 82 328. 179 2 glazing c!r im" 0.650 8 18.20 14.99 0 0 0 0 0 0 0 Ti13A40cs 2 glazing, cir b" 0.650 S 18.20 14.99 - 30 30 546 450 30 30 546 450 -11DO 0.390 s 0.00 : 0.00 0 0 0 '0 0 0 0. o 1�► 13AAas 0.143 w 4.00 2.19 48 48 192 105 0 0 0 0 1---G 2 glazing, dr bw-e 0.6m w 1820 33.77 0 0 0 0 0 0 0 0 r---G 2 ah3dom dr 10" 0.650 w 18.20 28.57 0 0 0 0- 0 0 0 " 0 C 16X19ow 0.408 - 1.59 1.37 169 - 169 268 231 238 238 . 377 325 F 22A4ph 1.3m - 38.02 0.00 169 19 722 0 238 31 1179 0 6 c)AED annsion 47 -15 Ermlope IoWgaln 2025 931 2975 1237 12 a) Infiltration 3m 96 585 157 b) Room verdallon 0 0 0 0 13 Ittertml gouts: 230 0 0 �Q oIherSw 20 Subtotal (Goes 6 to 13) 2383 1827 3550 1594 Less wdemal load 0 0 0 0 Less transfer 0 0 0 0 Redshbition 0 0 67 30 14 Subtotal 2383 1827 3626 1624 15 Duct Ioads 24% 40% 574 723 24% 40% 873 643 Total room load 2957 2550 4500 2267 W reptmed WnO 728 114 19W 101 Calculations ammmed.bvACCA to meet all n:nuimments of Manual J 8th Ed. C A-w Ig +� 2020-May-081 :32:01 RigthWde® Universal 201919.0.08 RSU08101 page 7 A E1DocumnetslWdghtsoft FNACWNG RESIDENCE:rup Calc = M.G Front Door feces: S -�- wrmhtsofr Right-M Worksheet' Jobs AHU 1 Date. May 08, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LAW- FORT PIERCE, FL 34946 Phone: M-466.6799 Fax 772-4664M Email: OUICKCALCS@AOLCOM 1 Room name CLST 5 SINKS 1.0 ft O ft 3 =eght 8.0 ft heallcod 8.0 It hea ool 4 Room dmensions 14.0 x 2.0 ft 7.0 x 7.0 ft 5 Roan area 28.0 fta 49.0 ft= Ty Construction Uxalae Or li1M Area (ftg Load Area (ft-) Load cumber @ftW ; F) (Bttthlft� or perimeter (ft) PUN or Whder (ft) (Btuh) Fleet Cad Gross NffS Heat Cool Gross WP1S Heat Cod 6 'h 13A4ocs M143 n 4.00 219 0 0 0 0 0 0 0. 0 2 glavrrg, cir taws 0.650 n MOD MOO 0 0 0 0 0 -0 0 .0 2 g4�ng, cir_low a 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2giaang.drkxre M850 n 0.00 0.00 0 .0. 0 0 0 0 0 0 11 W 13A-4ocs 0.743 a 4,00 219 8 8 32 18 0 0 0 0 13A-0ocs 0.143 s 4.00. 219 0 0 0 0 0 0 0 0 --G 2 gling dr kw-9 0.650 _ s 18.20 14.99 0 0_ 0 0 0 0 0 -0 I--G 2 wing, cU low$ 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 11130 0.390 s 0.00 moo 0 0 0 0 0 0 A 0 yJ 13A4om 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, dr b*e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 rI--CC 2 Abm it m cif low-e 0.650 w 1&2D 2&57 0 0 0 0 0 0 0 0 C . 16X190w , 0.408 - 1.59 1.37 28 28 44 38 49 49 .78 67 F 2244ph 1.358 - 31102 0.00 28 1 38 0 49 0 0 0 6 c)AlD elwsion -1 -4 Envelope bss/gain 114 55 78 63 12 a) k0tration 19 5 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Apptiarmdo0w 0 350 Subtotal (fines 6 to 13) 133 60 78 413 Less edema[ load 0 0 0 0 Less transfer 0 0 0 0 Re stdhAm -133 .60 33 15 14 Subtotal 0 0 111 428 15 Duct bads 24% 40% 0 0 24% 40°% 27 169 Total room load 0 0 138 598 Air regWred (cfrn) D D 6 27 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. i#i' wrtgr>�o�°e- 2020-May-0810:32:01 A& R4ghtSuite9 Universal 201919.0.08 RSUQS101 Page 8 E:\DocumetslWrightsoft WACWN G RESIDENrCE rup Cate = MJS Front Door faces: S / -�- wrightsoft° Right-J® Worksheei AHU 1 QUICK CALCS, INC. 317 ST LUCIE LAt-, FORT PIERCE. FL 34M Phone: 772466.6799 Fax 772-466.6796 Emafl: QUICKCALCSQAOLCOM Job: Date: May 08, 2020 ST 1 Room name TOLL RM 0 It 3 Roan l>egfit &Oft . heaV od 4 Room dimensions 7.0 x 7.0 It 5 Room area 49.0 ftz Ty Or Load number u (Bl tWF) {Bolt " perimeter (ft) p1h) perkneter Hit Cool Gross N!P/S Heat Cool Gross N/P/S Heat Cool 6 13A40cs 0.143 n 4.00 2-19 0 0 0 0 2 glazing, ctr bawe 0.650 n 0.00 0.00 0 0 0 0 2 glart ctr b" 0.650 n 18.20 14.99 0 0 0 0 29ftft drbve 0.650 n 0.00 0.00 0 .0 0 0 11 W 134flocs 0.143 a 4.00 2-19 0 0 0 0 13A-0ocs 0.143 _ s . 4.00 2.19 . 0 0 0 ;- 0 -G 2gla I g, drbw-e 0.650 s 18.20 14.99 0 0 0 0 1---G 2 gl. zft cir b*e 0.650 . s 18.20 14.99 0 0 0 0 LL__Qp 11D0 0.390 s 0.00 0.00 0 0 0 0 13A-0ocs 0.143 w 4.00 7-19 0 0 0 0 G 2 glazing, dr b" 0.65o w 18.20 33.77 0 0 0 0 z dadffn dr bw a 0.65o w 1&20 20.67 0 0 01 0 61 c)AED ewAusion -4 EnWw bss/g81n 78 63 12 a) hMrAw 0 0 b) Room ventila0on 0 0 13 Internal gains: Occupants Q 230 0 0 /od 360 Subtotal (tines 6 to 13) 78 413 Less edenrral bed 0 0 edstribution 33 15 14 SubtcW 111 428 15 Dud bads 24% 40% 27 189 Total room load 138 598 Air rem*ed (cfm) s Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. Ad- —..No ft- 2020-May-08 10:32.019 Right -Suite® lktiversal 201919.0.08 RSUO&101 page E:1DocuraiMstWrightsoa M/ACUONG RESIDENCErup Care = M.B Front Door faces: S wrightsoft• Right-J®Worksheet Job: AHU 2 Dace: May 08, 2020 Br• • QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE, FL 34946 Phone: 77246"M Fax 7724664M EmaT QUICKCALCS aQAOLCOM 1 2 3 4 5 Room name =ad wall Room two t Room cbmnsions; Room ales AHU 2 60.0 It 10.5 It 1301.0 ft2 - HALLWAY 0 ft 8.0 It heat/cm! 1.0 x 139.0 ft 139.0 ft2 Ty adw rer (Btt*ffVL F) Or (Bttdtlft2) Area pemuet (ft) LOW (Blatt) Area (ftj or Perimeter (ft) Load (&utt) Heat Cad Gross NIPIS HW Cod Gross NIPIS Heat Cool 6 11 13A4ocs 2 ghEft Ctr b" 20zmClrbwe 2gkW drlowe 13A4ocs M143 0.650 0.650 0.650 M143 n n n n a 4.00 18M 18.20 18.20 0.00 Z19 14.99 -14.99 14.99 0.00 604 12 60 48 0 484 .. 0 0 0 0 ISM 218 1 874 0 1059 .180 899 720 0 0 `0 0 0 0 0, 0 0 0 0 0 0 0 0 0 . 0 0 0 0 0 W 13A-0acs 2 gI, "g dr lower 2 grating, dr b*e 11130 13A4ocs 0.143 0.650 0.650 0.390 0.143 s s. s s w 4.00 0.00 0.00 10.92 0.00 Z19: 0.00 0.00 10.34 0.00 40 0 - 0 20 0 20 0 0' 20 0 .80 0. 0- 219 0 44 0 208 0 0 0 0 0 0 - 0 0. 0 0 0 0 0 _ 0 0 0 0 C 2 gbzhx;, dr bo v e 2 cgazffxL dr lowe 16 saw 0.650 0.650 0.408 w w - 0.00 0.00 1.59 0.00 0.00 •1.W 0 0 : 1301 0 0 1301 0 0 - ..2063 0 0 - 1780 0 0 .139 0. 0 139 0 0 220 0 0 , 190 F 22A4ph 1.358 - 3.8.02 0.W 1301 60 2281 0 139 0 0 0 6 c)AED ammion 0 0 Envelope bW9Edn 8765 409 220 190 12 a) in itration b) Room wdilatton 1519 0 407 0 0 0 0 0 13 Intemal gaas: Occupants @ 230 AWPfWimisIodier 0 0 8100 0 0 0 Subtotal (fines 6 to 13) 10284 13396 220 190 14 15 Less wdemal load Less transfer Recilsfibution Subtotal Dud bads 30% 341A 0 0 0 10284 3108 0 0 0 13396 45M 3045 34%. 0 0 220 0 0 0 0 -190 0 0 Total room toad _7 Air � (dm) 13392 179007F71 0 0 0 0 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed -�- wr�gMtmoTe- . Rlght.Suite® Universal 201919.0.08 RSU08101 2020•May-08 P� 0 .� E:1Documcets%WrlghtwR HVAC\KING RESIDENCE rap Calc= M,a Fmnt Door faces: S -�+ wrightsoft Right-JO Worksheet Job: AHU 2 Dde: May 08, 2020 • QUICK CALLS, INC. Dsy: 317 ST LUCIE LANE. FORT PIERCE, FL 34946 Phone: 772.466• 6799 Fax 772.4664M Email: GU1CKCALCS@AOLCOM 1 Roan name DOTCHBV FOYER 2 l waft 1&0 It 5.0 ft 3 Roan height I 12.0 ft heaticool &0 ft heaticod 4 Room dimension 1&0 x 20.0 It &0 x 1&0 ft 5 Roan area 36D.0 ft' 9D.0 W Ty Construction Uxaloe Or HTM Area M Load Area M Load number (eft;') @WM or Pier (ft) W) or perimeter (ft) ( ) Heat I Cod Gross NUPlS Heat Cod Gross WP/S Heed Cod 6 13A4ocs 0.143 n - 4.00. 219 216 2W 817 446 0 0 0 0 2 gWzba cir lawe 0.650 n 1&2D - " VL99 12 0. 218 180 0 0 0 0 2glazing, cirlow.e 0.650 n 1&20 14.99 0 0 0 0 0 0 0" 0 2 giaarg, dr law a 0.650 " n Y20 8 14:99 0 0 0 0 0 0 0 0 1 i W i3A-0ocs 0.143 a 0.00 (1AO 0 0 0 0 0 0 0 0 13A4ocs 0.143 s 4.00 Z19 0 0 0 0 40 20. 8D 44 2"gtaztag, cir IN" 0.650 5 0.00 (10D 0. 0 0 0 0 0 0 .0 2 glaft cir b*e 0.650 - s 0.00 MOD 0 0 0 0 0 0 0 0 1100 0.390. s 10.92 10.34 0 0 0 0 20 20 219 268 13A-0acs 0.143 w 0.00 0.00 0 0 0 0 0 0 0 0 2glaftdrlome 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glad= cir fow•e 0.650 w 0.00 0.OD 0 0 0 0 0 0 0 0 C 16XISOW 0.408 ;• - 1.59 " 1.37 . .. 360 " ' 360 :571 493 90 90 143 123 F 22A4ph 1.358 - 38.02 0.00 360 18 654 0 90 5 190 0 6 c)AED =asion 0 0 awelope losslgain 2290 1119 632 374 12 a) Infiltration 509 136 94 25 b) Rcan wMation 01 0 0 0 13 Internal gains: Occupants Qo 230 0 0 3700 60 Subtotal pines 6 to 13) 2800 4955 726 900 Less edemal load 0 0 0 0 Less traisfer 0 0 0 0 14 Subtotals 2932 5069 755 925 15 Duct loads 30% 34% 886 1704 30% 34% 228 311 Tetal morn load 3818Air 12 36 rewired reed (cfm) 224 2984 58 54 Calculations awroved bvACCA to meet all requirements of Manual J 8th Ed. c,at- W20-May-0810,3201 C.� RigMSutte® Universal 201919.0.08 RSU08101 Page 11 E 1Documnets\Wrtghtsort WACW NG RESIDENCE.rup Calc = MJ8 Front Door faces: S -�- wrightsoft' Right-J® Worksheet Job: AHU 2 dace: May 08, 2020 Br - QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-4654rM Email: QU1CKCALCW01-COM 1 Roan name FAMLYROOM Ur&JTYRM 3 ao Rn height 120 ft 23.0 ft heat/wd 8.0 ft Oft he wcool 4 5 Room dons Rom ate 23.0 x 20.0 ft 460.0 fi= 14.0 x 7.0 ft 98.0 ft' Ty Corstnrc6on MgTd er U-raka (Bbrtdit; F) Or H7'M (Btl W Area (ft') or Perimeter (ft) load (Btuh) Area (ft') or phmter (ft) Load (Btuh) Heat Cool Gross NffS Hem Cod Gross WP1S Heat Cad 6 {-� 13A4ocs 2 glazing eir lama 2 Wig, dr bawe 0.143 0.650 0.650 n n n 4.0D 1&20 18M 219 14.99 14.99 . 276 . 0 M 168 0 0 - 673 0 1 368 .. 0 899 0 0 0 0: 0 0 0 0 0 0 0 0 W 11 2 gaift dr Iowa 13A4ocs 0.650 0.143 n a 18.20 0.0D 14.99 0.00 48 0 0 0 . 874 0 72D 0 0 0 0 0 0 0 0 0 1q/ t 13AAow 2gtazfra dr b" 2 gWng; dr low.-e. 11D0 13Adocs 0.143 0.650 0.650 0.390 0.143 s s s. s w 4.00 moo (1O 1092 0.00 Z19 0.00 0.00 10.34 0.00 0 0 0 0 0 0 0- 0 0 0 0' 0 0-. 0 0 0 0 0 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ---C' ;L-GD Vf1 I---t' TC C 2 glazing dr irm-e 2 Alw*n cir Iowa 10094kKI - 0.650 0.650 0.408 w w .- 0.00 Q00 1.69 0.00 MOD 1.37 0 0 460 0 0 460 0 0 729 0 0 620 0 0 98 0 0 98 0 0 155 0 0 134 F 22A4ph 1.358 - 38.(2 0.00 460 23 875 0 98 0 0 0 6 c)A® eaxtesion 0 0 Flweiope bosslgain 4242 2616 155 134 12 a) Infiltration 651 174 0 0 b) Room wee ntflatim 0 0 1 0 0 13 Internal gainv. Occupants @ 230 0 0 0 0 Appfiancedothe r 23M 600 Subtotal (ilnes 6 to 13) 4893 5090 155 734 Less external load 0 0 0 0 Less transfer 0 0 0 0 lrbon Rethli 59 5i 0 0 14 Subtotal 4952 5141 155 734 15 Duct keft 30%% 34% 1496 1729 30% 34% 47 247 --T Total room toad 6448 6870 1 1 202 981 Air re�cd (af n) 379 121 43 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrl h>tso*t- 9 ay 2020-M -0810:3201 A RightSuite® tMivemal 201919.0.08 RSU08101 Page 12 E:\DocurrnetsMightsoft HVAC%IUNG RESIDENCErup Calc - M.8 Front Door races: S -t- wrightsoft° Right-J® Worksheet Job: AHU 2 Date: May 08, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LA F. FORT PIERCE, FL 34%6 Phone: 772-4664M Fax 772-466-6796 Emil: QUICKCALCS@AOLCOM 1 Room row ENTRY PANTRY 2 j vyap 4.0 ft 10.0 ft 3 Room tvght 8.0 ft Fleat/cad 8 0 ft tseaUcod 4 Room cilmensions 1.0 x 104.0 ft 10.0 x 5.0 ft 5 Room area 104.0 ft2 50.0 fF Ty �r (" �Wheter Load Area Load number (�t�tfft; F) (Btl1 " orHTm (ft) (Blob) I aPerimeter (ft) (Blot►) Heat Coo! Gross N/P/S Heat Cod Gross N/P/S Heat I Cod 6 13A4ocs 0.143 n 4.00 Z19 32 32 128 70 80 80 320 175 2glaft dr b" 0.650 n 18.20 14.99 0 .0 0 0 0 0 0 0 Ti 2 &zka dr [owe 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 gWri% dr low- 0.650 n 18.2D 14.99 0 0 0 0 0 0 0 0 11 w 13A4ocs 0.143 a 0.00 0.00 0 0 0 0 0 0 0 0 13AAocs 0.143 s 4.OD 2.19 0 0 0 0 0 0 0 0 2 grazing, dr lo" 0.650 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, dr tovwe 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 11DO 0.390. s 10.92 10.34 .0 0 0 0 0 0 0 0 13Ar4ocs 0.143 w O.OD 0.00 0 0 0 0 0 0 0 0 2 glazirg, dr low-e 0.650 w 0.00 moo 0 0 0 0 0 0 0 0 2!>wdm cir b" 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 C 1w9ow 0.408 . - 1.59 137 1 104 .165 142 50 60 79 68 F 22A4ph 1.358 - 38.02 0.00 104 4 152 0 50 10 380 0 6 c)AED exolasion 0 0 Envelope Ioss/gain 445 212 780 243 12 a) Udltratian 75 20 189 51 b) Room ventilation 0 0 0 0 13 tdemal gains: 230 0 0 � j0 Soo Subtotal (ones 6 to 13) 521 733 968 794 Less ettemat load 0 0 0 0 Redstnbution 0 0 0 0 14 Subtotal 521 733 968 794 15 Dud bads 30% 34% 157 246 3D% 34°/a 293 W Total room load 678 979 1261 1061 Air rem&ed term) 40 43 74 47 Calculations approved. by ACCA to meet all requirements of Manual J 8th Ed. wrlgFatsota t� 2020-May-W 10:32:01 A ""^ RkjMSutte® Universal 201919.0.08 RSU08101 Page 13 EADocumnets\Wrightsoft WACUUNG RESIDENCE.rup Calc = MJS Front Door faces: S Duct System Summary Job: -�- wrightsoft y Date: May 08, 2020 AHU 1 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34M Phone. 772466ZM Fax 772-466-6796 Emil: QUICKCALCSQAOLCOM Project• • For. DANIELLE KING, K & S INDUSTRIES 6800 PEACOCK ROAD, PORT ST WCIE, FL 34987 Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 980 cfm Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 980 cfm 267 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BEDROOM 2 h 2901 125 115 1.000 7.0 Ox 0 VIFx 67.9 155.0 sty BEDROOM 3 c 2664 100 119 1.000 7.0 Ox 0 VIFx 34.9 135.0 st4 BEDROOM 4 h 2957 128 114 1.000 7.0 OxO VIFx 32.9 135.0 st4 BEDROOM 5 h 4500 194 101 1.000 7.0 OxO VIFx 15.5 115.0 st1 HALF BATH c 696 6 31 1.000 5.0 OxO VIFx 68.6 155.0 Sty • BATH c 1252 54 56 1.000 6.0 OxO ViFx 67.0 155.0 st5 •TOILET h 791 34 22 1.000 6.0 Ox0 VIFx 86.7 175.0 st6 M WIC h 2678 111 W 1.000 6.0 OxO VIFx 70.9 166.0 51:5 MASTER BEDROOM c 2863 105 128 1.000 7.0 Ox0 VIFx 82.6 175.0 st6 MASTER BEDROOM -A C 2863 105 128 1.000 7.0 Ox 0 VIFx 92.2 175.0 st6 SINKS c 598 6 27 1.000 5.0 Ox 0 VIFx 15.0 115.0 SO TOILET RM c 598 6 27 1.000 5.0 Ox 0 VIFx 14.4 115.0 st1 WIC 3 C 537 2 24 1.000 5.0 Ox 0 VIFx 32.6 135.0 st4 WIC 4 c 537 2 24 1.000 5.0 Ox 0 VIFx 32.6 135.0 st4 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) Wm) FR (fpm) (n) (In) Material Trunk st6 Peak AVF 243 279 1.000 631 9.0 0 x 0 ViniFix St5 sty Peak AVF 541 544 1.000 692 12.0 0 x 0 VinlFtx st4 st4 Peak AVF 774 825 1.000 772 14.0 0 x 0 VinlFlx st1 SO Peak AVF 980 980 1.000 702 16.0 0 x 0 VinlFlx wrightsaft°° -- 2020-May-08 10.32:08 +�+•�.,� RightSu9e® llniversa1201919.0.08 RSU08101 pegs 1 E1Docur netstWrlghtso8 WACIKING RESIDENCErup Cato = MJ8 Front Door faces: S Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb2 Ox0 980 980 0 0 0 0 ox 0 VIFx Wrightsoft- - 2020MW-W 10.32 08 '� + `�e �»•wm.. rmo.. RlghtSuite® Universal 201919.0.08 RSLM101 Page 2 E:1DocunmetslWrightsoll WACWNC RESIDENCE.rup Calc = MJS Front Door faces: S Duct System Summary Job: - - wrightsoft� AHU 2 Y Bye: May 08, 2020 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466.6799 Fax 772 466-67% Emil: QUICKCALCSQAOLCOM f1roject intormation For: DANIELLE KING, K & S INDUSTRIES 6800 PEACOCK ROAD, PORT ST LUCIE, FL 34987 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 787 cfm Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 787 cfm 186 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Cig (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk ENTRY c 979 40 43 1.000 6.0 Ox 0 VIFx 17.9 115.0 st3 FAMILY ROOM h 3224 189 151 1.000 8.0 OxO VIFx 45.9 135.0 st8 FAMILY ROOM -A h 3224 189 151 1.000 &0 Ox 0 VIFx 49.2 135.0 st7 FOYER h 984 58 54 1.000 6.0 Ox0 VIFx 51.2 135.0 st7 VjTCHEN c 3387 112 149 1.000 8.0 OxO VIFx 46.9 135.0 st8 K=fmwa c 3387 112 149 1:000 8.0 OxO VIFx 24.0 115.0 st2 PANTRY h 1261 74 47 1.000 6.0 OxO VIFx 19.0 115.0 st3 UTILITYRM c 981 12 43 1.000 6.0 Ox0 VIFx 17.1 115.0 s12 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (n) Material Trunk st7 Peak AVF 247 205 1.000 708 &0 0 x 0 VinIFIX st2 St2 Peak AVF 371 397 1.000 729 10.0 0 x 0 VinlFlx st8 PeakAVF 302 300 1.000 683 9.0 0 x 0 VinlFlx st3 st3 Peak AVF 416 390 1.000 762 10.0 0 x 0 VirdFix -�- wrightsoft® 2020May-08 103E-0s �- ..w.ve. nm•.r�w., RigMSaiteOUnhNnal201919.0.08RSW8101 Page E1DocumnetslWrightsoR WVACUONG RESIDENCE.rup Calc = MJ8 Front Door faces: S Return Branch Detail Table Name Grille Size (in) Htg (dm) Cig (cfm) TEL (f0 Design FR Veloc (fpm) Diam (in) H x W Qn) Stud/Joist Opening (in) Duct Matl Trunk rb9 Ox0 787 787 0 0 0 0 Ox 0 VIFx +wrigtIftoft R19 SURe® U ftersa1201919.0.08 RSU08101 Imo nnay-0s 10:3208 Page 4 E:1Dmn ocuetslWrightso8 FiVACW NG RESIDENCE.rup Calc = M;IB Front Door faces: S