HomeMy WebLinkAboutBuilding Plans0 0 I r) 0'-93" 4' SWINGING --------------------------Daef -------------------------------- I on R m ROLL -UP 1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS, 2. THIS STRUCTURE IS DESIGNED AS A NON —HABITABLE UTILITY/STORAGE BUILDING (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST, AND NOT PROVIDED AND INSTALLED BY CARPORTS ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. CARPORTS ANYWHERE NOR THE ENGINEERING DESIGN SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. 3. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION C101.4.2. 4. ALL STEEL TUBING SHALL BE 50 KSI STEEL AND MEETS/EXCEEDS GALVANIZATION PER ASTM A1003/A1003M-15. 5.PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER. 6. ROOF AND WALL SHEATHING SECURED WITH #12-143/4" SELF —DRILLING SCREWS WITH SEAL WASHERS ® 6" O.C. MAX. 7. FIELD FRAMING CONNECTIONS SECURED WITH #12-14x3/4" SELF —DRILLING SCREWS. 8. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED. NO WELDING ONSITE. ALL WELDING DONE IN SHOP BY A CERTIFIED WELDER. 9. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2" DIAMETER & 2,500LB TENSILE STRENGTH. 10. 12 OR 14GA. FRAMING IS 2.5"x2.5" TUBE STEEL. NIPPLES ARE 2.25"x2.25" TUBE STEEL. —TO BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDANT PER SECTION R318 AND 1816 OF THE 2017 FLORIDA BUILDING CODE, 6TH EDITION —BOTTOM OF CONCRETE FOOTING SHALL BE MINIMUM OF 12" BELOW UNDISTURBED OR ENGINEERED GRADE CONCRETE: -MINIMUM 2,500 PSI COMPRESSIVE STRENGTH AT 28 DAYS —ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE PROPOSED STRUCTURE SHALL BE DESIGNED TO SLOPE AWAY FROM THE STRUCTURE REINFORCING STEEL (REBAR) REQUIREMENTS: —MINIMUM GRADE 40 STEEL —REBAR MAY BE BENT IN SHOP OR FIELD PROVIDED: —THE REBAR IS BENT COLD —THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED 6—BAR DIAMETERS: AND —REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT IN CASES WHERE DOWELS NEED TO BE BENT TO ALIGN WITH A VERTICAL CELL THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF 1" HORIZONTALLY TO 6" VERTICALLY. —COVER: —3" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH SOIL OR WEATHER, AND 1j" ELSEWHERE. REBAR EMBEDDED IN GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF J" FOR FINE GROUT, AND J" FOR COARSE GROUT BETWEEN REBAR AND ANY FACE OF A CELL REBAR USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER (INCLUDING GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER, AND 1}" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR WEATHER. GALVANIZATION: —METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY EXPOSED TO WEATHER SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A 163, CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED DIRECTLY TO WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED. MIN. 2,500 PSI 4" CONCRETE SLAB WITH W.W.F. (OR FIBER MESH) AND 12"x12" REINFORCED FOOTER PERIMETER A"x54" EXPANSION ANCHOR WITHIN 6" OF EACH POST/TRUSS ALONG SIDES AND EVERY OTHER END —WALL POST 2" MIN. —I II- ABASE RAIL -------------------------------------- I I I I Z/o31V I i i RECEIVED FEB 0 5 1011 Permitting Department Si, Lucie County _ Ili w W •a N 2,500 PSI 4" CONCRETE 1-1I a, SLAB WITH 10GA. W.W.F. OR FIBER MESH (2) #5 REBAR ® 6" O.C. MINIMUM SOIL BEARING CONTINUOUS WITH MINIMUM CAPACITY 500 PSF(TYP.) 25" OVERLAP SPLICE CONCRETE FOUNDATIONZBASE RAIL ANCHOR DETAIL 2 5" PLAN VIEW DOOR FRAMING J" RECESS OOR WIDTri ELEVATION VIEW DOOR FRAMING RECESS ---\ IL T •75"J 4" OOR WIDTH OPTIONAL ROLL -UP DOOR CONCRETE SPLASH -GUARD RECESS 12"x12" REINFORCED FOOTER =ILE Cot ST. LL I CODE VERSION IFBC 2020 7th Edition4l BUILDING TYPE IUTILITY STRUCTURE II CONSTRUCTION TYPE II—B RISK CATEGORY 1 FIRE PROTECTION INONE FIRE SUPPRESSION SYSTEM INONE U SPEED ENCLOSURE JENCLOSED INTERNAL PRESSURE COEFF. +/— 0.18 IMPORTANCE FACTOR 11.0 ROOF DEAD LOAD 11OPSF FLOOR DEAD LOAD 1OPSF FLOOR LIVE LOAD 5OPSF "R"RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE INO SQUARE FOOTAGE 11,200 SQ. FT. 2020 FBC urtnnn o,: MTe P Ate` 7/26/19 n413 PineTree Dr., Ft. Pierce, 34982 SIZE' 40-L X 30-W X 12-H 0 ro% VIP IANCE W �4�/tp{i ` SMatthse"W4T BaldWln P E.' kn Florida,Llcense #64608 Sheet: _'s„ CA-1 OF 4 MINIMUM 6" TS NIPPLE. NIPPLE MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH SECURED TO WALL POST WITH SC�) 12 14xj" SELF—DRILLING/_2"x2"x2" EWS SCREWS 14x4" SELF —DRILLING V \ BASE RAIL NIPPLE T ivPPLE TO" 16 GA. ANGLE CUP BASE RAI SECURED WITH (4) #12-14x4" SELF —DRILLING SCREWS 2"x2"x2" 16 GA. ANGLE CUP _ _ _ _ SECURED WITH (4) #12-14x1" 7—I 1 r=- I I i I I-1 I-1 I IEl �—I 11-1 SELF —DRILLING SCREWS 1(- INTERMEDIATE POST TO POST TO BASE RAIL CONNECTION 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14xj" SELF —DRILLING SCREWS NON—STRUCTURAL HEADER OR WINDOW INTERI, #12-14)4" SELF -DRILLING SCREWS ® 10" O.C. MAX., 3" MAX. FROM CORNERS HORIZONTALLY/ 4" MAX. FROM CORNERS VERTICALLY 1Z„ EXTERIOR DOOR FRAME TO POST CONNECTION END POST TO BASE RAIL HEADER/BASE RAIL/OR CONNECTION WINDOW RAIL DETAIL 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14x4" SELF —DRILLING SCREWS VARIES TO STD. MA�3SPM SPACING STD. MAX. SP*CING MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH (4)#12-14)j" SELF —DRILLING SCREWS SIDE WALL ROLL —UP DOOR/FRAME OUT POST TO TRUSS HEADER DETAIL CONNECTION PER MANUFACTURERS INSTRUCTIONS 26 GAUGE ROOF SHEATHING SECURED WITH (1)#12-14)l SELF —DRILLING SCREWS 2-1-2-1' (6" O.C. (9" O.C. MAX.)) #14x1" SELF —DRILLING SCREWS ® 6" O.C. MAX. & 6" MAX. Lt-�00. MAN'FROM CORNERS MpA ROLL —UP DOOR TO POST CONNECTION 1" 16 GAUGE FURRING CHANNEL 48" O.C. MAX. SECURED WITH (2)#12-14x1" SELF —DRILLING SCREWS TO EACH RAFTER. 2"x2%2" 16 GA. ANGLE CUP SECURED WITH (4) #12-14x1" SELF —DRILLING SCREWS SINGLE OR DOUBLETS HEADER CONNECTION DETAIL OPTION 1 26 GAUGE ROOF SHEATHING SECURED WITH (1)#12-14x4" SELF —DRILLING SCREWS '2-1-2-1' (6" O.C. (9" D.C. MAX.)) 1" 16 GAUGE FURRING CHANNEL 48" O.C. MAX. SECURED WITH (2)#12-14x1" SELF —DRILLING SCREWS TO EACH RAFTER, ROOF PANEL CONNECTION VERTICAL SHEATHING OPTION Mom. —0" EAVE & RIDGE REINFORCED ROOF PANEL CONNECTION (RIDGE 3r AND EAVE 3e) Design Pressures - 165 mph Basic Wind Speed Zone Roof Wall 1 2n 2r 2e 3r 3e 4 5 9.6 11.8 9.6 9.6 17.3 17.3 17.3 20.8 -13.4 1 -42.6 1 -34.0 1 -13.4 1 -74.4 1 -62.6 -19.3 1 -26.3 MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH (4)#12-14xj" SELF —DRILLING AdWO SCREWS CAMMAINIM M ME OR DOUBLE TS HEADER CONNECTION DETAIL OPTION 2 NIPPLE TRUSSED RAFTER CONNECTION DETAIL LE TO 1 "x2j" 16 GA. = U—CHANNEL BRACE, MIN. 24" UP TO 7' POST, Mm 48" OVER 7' POST. MIN. 45' TO MAX. 60• FROM HORIZ. (EXCLUDE END —WALLS). SECURED WITH (4)#12-14)4" SELF —DRILLING SCREWS. MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH SC) 12 14)j" SELF —DRILLING BOX EAVE RAFTER TO POST CONNECTION DETAIL APPROVED PRODUCTS APPROVAL NO. ROOF SHEATHING Carports Anywhere FL27402.1—R1 Hampton Rib Roof Panel WALL SHEATHING Carports Anywhere FL27403.1 Hampton Rib Wall Panel SWINGING DOOR ELIXER DOOR AND METAL COMPANY FL17996.5 407 STEEL DOOR ROLL —UP DOOR JANUS INTERNATIONAL CORPORATION FL21450.3 SERIES 3100 (CODE VERSION rBC 2020 7th Edition,ll IeCrC_7_1A BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U INTERNAL PRESSURE COEFF. +/— 0.18 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD 0PSF OR 3001b P.L. FLOOR DEAD LOAD 1OPSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 1,200 SQ. FT. FBC DESCRI MTB 7/26/19 13 PineTree Dr., Ft. Pierce, 34982 40'L X 30'W X 12'H ► VIE'ED FOR -,E C COMPLIANCE ST. LUCIE COUNTY O C <r I Q r =+ Matthe}T_,BaldWin P.E. x' -Florida' License #64608 o Sheet: CA-4 OF 4