Loading...
HomeMy WebLinkAboutEnergy Code_-_FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: VEGA-REYES RESIDENCE Builder Name: Street: 401 E. MIDWAY ROAD Permit Office: ' ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: WILLIAM VEGA AND OLIANNE REYES Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St: Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2181.3 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Int Insul, Exterior R=4.1 1872.00 ft2 b. Frame - Wood, Adjacent R=11.0 309.33 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (2455.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2455.00 ft2 6. Conditioned floor area above grade (W) 2455 b. N/A R= ft2 c. N/A R= ft2 Conditioned floor area below grade (W) 0 11. Ducts R ft2 7. Windows(378.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 200 a. U-Factor: Sgl, U=1.06 330.00 ft2 SHGC: SHGC=0.28 b. U-Factor: Sgl, U=1.03 48.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a. Central Unit 46.5 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 8.598 ft. Area Weighted Average SHGC: 0.285 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2455.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2455.00 ft2 • b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.154 Total Proposed Modified Loads: 79.05 PASS Total Baseline Loads: 79.49 I hereby certify that the plans and specifications covered by Review of the plans and �Tf'ST�T this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: DATE12 qO Before construction is completed this building will be inspected for compliance with Section 553.908 I hereby certify that this bui0,,signed, is in compliance Florida Statutes.' ' with the Florida Energy Cod OWNER/AG NT BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 11/6/202011:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: VEGA-REYES RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2455 Lot # Owner Name: W ILLIAM VEGA AND OLIANN Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 401 E. MIDWAY ROAD Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Etasting: New (From Plans) Comment: CLIMATE J Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2455 24400.9 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 280 2604 No 0 1 1 Yes Yes Yes 2 M WIC 69 641.7 No 0 1 Yes Yes Yes 3 M BATH 188 1748.4 No 0 1 Yes Yes Yes 4 LAUNDRY RM 60 558 No 0 1 No Yes Yes 5 DINING RM 154 1647.8 No 0 1 Yes Yes Yes 6 KITCHEN 350 3745 Yes 0 1 No Yes Yes 7 LIVING RM 500 5350 No 0 1 Yes Yes Yes 8 FOYER 117 1251.9 No 0 1 Yes Yes Yes 9 DEN CLST 20 186 No 0 1 No Yes Yes 10 BATH 2 82 762.6 No 0 1 Yes Yes Yes 11 DEN 156 1450.8 No 0 1 Yes Yes Yes 12 CLST 2 18 167.4 No 0 1 Yes Yes Yes 13 BEDROOM 2 151 1404.3 No 0 1 1 Yes Yes Yes 14 HALL 2 24 223.2 No 0 1 No Yes Yes 15 BEDROOM 3 161 1497.3 No 0 1 1 Yes Yes Yes 16 BATH 3 91 846.3 No 0 1 Yes Yes Yes 17 HALL 16 148.8 No 0 1 No Yes Yes 18 CLST 3 18 167.4 No 0 1 Yes Yes Yes 11/6/202011:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 34 ft 0 280 ft2 ____ 1 0 0 2 Slab -On -Grade Edge Insulation M W IC 8 ft 0 69 ft2 ____ 1 0 0 3 Slab -On -Grade Edge Insulation M BATH 12 ft 0 188 ft2 ____ 1 0 0 4Slab-On-Grade Edge Insulation LAUNDRY RM 1 ft 0 60 ft2 ____ 1 0 0 5 Slab -On -Grade Edge Insulation DINING RM 12 ft 0 154 ft2 ---_ 1 0 0 6 Slab -On -Grade Edge Insulation KITCHEN 1 ft 0 350 ft2 -___ 1 0 0 7 Slab -On -Grade Edge Insulation LIVING RM 25 ft 0 500 ft2 ____ 1 0 0 8 Slab -On -Grade Edge Insulation FOYER 9 ft 0 117 ft2 -___ 1 0 0 9 Slab -On -Grade Edge Insulation DEN CLST 1 ft 0 20 ft2 ____ 1 0 0 10SIab-On-Grade Edge Insulation BATH 2 loft 0 82 ft2 -___ 1 0 0 11Slab-On-Grade Edge Insulation DEN 29 ft 0 156 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation CLST 2 2 ft 0 18 ft2 ---- 1 0 0 13SIab-On-Grade Edge Insulation BEDROOM 2 11 ft 0 151 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulation HALL 2 1 ft 0 24 ft2 _--- 1 0 0 15SIab-On-Grade Edge Insulation BEDROOM 3 13 ft 0 161 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulation BATH 3 27 ft 0 91 ft2 ____ 1 0 0 17SIab-On-Grade Edge Insulation HALL 1 ft 0 16 ft2 ____ 1 0 0 18SIab-On-Grade Edge Insulation CLST 3 2 ft 0 18 ft2 ____ 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2746 ft2 0 ft2 Medium N 0.2 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2455 ft2 N N 11/6/2020 11:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 280 ft2 0.1 Wood 2 Under Attic (Vented) M WIC 30 Blown 69 ft2 0.1 Wood 3 Under Attic (Vented) M BATH 30 Blown 188 ft2 0.1 Wood 4 Under Attic (Vented) LAUNDRY RM 30 Blown 60 ft2 0.1 Wood 5 Under Attic (Vented) DINING RM 30 Blown 154ft2 0.1 Wood 6 Under Attic (Vented) KITCHEN 30 Blown 350 ft2 0.1 Wood 7 Under Attic (Vented) LIVING RM 30 Blown 500 ft2 0.1 Wood 8 Under Attic (Vented) FOYER 30 Blown 117 1`112 0.1 Wood 9 Under Attic (Vented) DEN CLST 30 Blown 20 ft2 0.1 Wood 10 Under Attic (Vented) BATH 2 30 Blown 82 ft2 0.1 Wood 11 Under Attic (Vented) DEN 30 Blown 156 ft2 0.1 Wood 12 Under Attic (Vented) CLST 2 30 Blown 18 ft2 0.1 Wood 13 Under Attic (Vented) BEDROOM 2 30 Blown 151 ft2 0.1 Wood 14 Under Attic (Vented) HALL 2 30 Blown 24 ft2 0.1 Wood 15 Under Attic (Vented) BEDROOM 3 30 Blown 161 ft2 0.1 Wood 16 Under Attic (Vented) BATH 3 30 Blown 91 ft2 0.1 Wood 17 Under Attic (Vented) HALL 30 Blown 16 ft2 0.1 Wood 18 Under Attic (Vented) CLST 3 30 Blown 18 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 NE Exterior Concrete Block - Int InsuMASTER BE 4.1 20 0 9 4 186.7 ft2 0 0 0.2 0 2 SE Exterior Concrete Block - Int InsuMASTER BE 4.1 14 0 9 4 130.7 ft2 0 0 0.2 0 3 NE Exterior Concrete Block- Int Insul M W IC 4.1 8 0 9 4 74.7 ft2 0 0 0.2 0 4 NE Exterior Concrete Block - Int Insul M BATH 4.1 12 0 9 4 112.0 ft2 0 0 0.2 0 5 NW Garage Frame - Wood M BATH 11 10 0 9 4 93.3 ft2 0 0.1 0.2 0 6 SW Garage Frame - Wood M BATH 11 2 0 9 4 18.7 ft2 0 0.1 0.2 0 7 NW Garage Frame - Wood LAUNDRY R 11 10 0 9 4 93.3 ft2 0 0.1 0.2 0 8 NE Garage Frame - Wood LAUNDRY R 11 2 0 9 4 18.7 ft2 0 0.1 0.2 0 9 SW Exterior Concrete Block - Int InsulDINING RM 4.1 1 0 10 8 10.7 ft2 0 0 0.2 0 10 NW Exterior Concrete Block - Int InsulDINING RM 4.1 11 0 10 8 117.3 ft2 0 0 0.2 0 11 NE Garage Frame - Wood DINING RM 11 8 0 10 8 85.3 ft2 0 0.1 0.2 0 12 SE Exterior Concrete Block - Int Insul LIVING RM 4.1 25 0 10 8 266.7 ft2 0 0 0.2 0 13 NW Exterior Concrete Block - Int Insul FOYER 4.1 9 0 10, 8 96.0 ft2 0 0 0.2 0 14 SW Exterior Concrete Block - Int Insul BATH 2 4.1 10 0 9 4 93.3 ft2 0 0 0.2 0 15 NE Exterior Concrete Block - Int Insul DEN 4.1 4 0 9 4 37.3 ft2 0 0 0.2 0 16 SW Exterior Concrete Block - Int Insul DEN 4.1 13 0 9 4 121.3 ft2 0 0 0.2 0 17 NW Exterior Concrete Block - Int Insul DEN 4.1 12 0 9 4 112.0 ft2 0 0 0.2 0 18 SW Exterior Concrete Block - Int Insul CLST 2 4.1 2 0 9 4 18.7 ft2 0 0 0.2 0 19 SW Exterior Concrete Block- Int InsuBED ROOM 2 4.1 11 0 9 4 102.7 ft2 0 0 0.2 0 20 SW Exterior Concrete Block - Int InsuBEDROOM 3 4.1 13 0 9 4 121.3 ft2 0 0 0.2 0 21 NE Exterior Concrete Block- Int Insul BATH 3 4.1 7 0 9 4 65.3 ft2 0 0 0.2 0 22 SE Exterior Concrete Block - Int Insul BATH 3 4.1 13 0 9 4 121.3 ft2 0 0 0.2 0 11/6/2020 11:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width El -Value Et In Height Et In Area Sheathing Framing P-Valf ie F:raCtqon Solar Belo Ahqor w 23 SW 24 SW Exterior Exterior Concrete Block - Int Insul BATH 3 Concrete Block - Int Insul CLST 3 4.1 7 0 4.1 2 0 9 4 65.3 ft2 9 4 18.7 IF 0 0 0 0 0.2 0 0.2 0 DOORS # Ornt Door Type Space Storms U-Value Ft Width Height In Ft In Area 1 2 NE NW Insulated BATH 3 Insulated LAUNDRY R None None .23 2 .23 3 6 8 8 20IF 24 IF WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NE 1 Metal Low-E Single Yes 1.06 0.28 N 20.0 ftz 2 ft 0 in 1 It 4 in None None 2 SE 2 Metal Low-E Single Yes 1.06 0.28 N 35.0 ft2 12 ft 0 in 1 ft 4 in None None 3 NE 4 Metal Low-E Single Yes 1.06 0.28 N 12.0 ft2 2 ft 0 in 1 It 4 in None None 4 NW 10 Metal Low-E Single Yes 1.03 0.32 N 30.0 ft2 10 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 5 NW 10 Metal Low-E Single Yes 1.03 0.32 N 18.0 ft2 10 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 6 SE 12 Metal Low-E Single Yes 1.06 0.28 N 128.0 ft2 12 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 7 NW 13 Metal Low-E Single Yes 1.06 0.28 N 48.0 IF 12 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 8 SW 14 Metal Low-E Single Yes 1.06 0.28 N 6.0 IF 2 It 0 in 1 ft 4 in None None 9 SW 16 Metal Low-E Single Yes 1.06 0.28 N 25.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 10 NW 17 Metal Low-E Single Yes 1.06 0.28 N 25.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 11 SW 20 Metal Low-E Single Yes 1.06 0.28 N 25.0 ft2 2 ft 0 in 1 ft 4 in None None 12 SW 23 Metal Low-E Single Yes 1.06 0.28 N 6.0 ftz 2 It 0 in 1 ft 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 440 ft2 440 ft2 32 ft 9 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH•50 1 Wholehouse Proposed ACH(50) .000442 2846.8 156.28 293.92 .1671 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 11/6/2020 11:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 46.5 kBtu/hr 1395 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 200 ft2 Attic 20 ft2 Default Leakage Garage (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Coolin Jan Feb [ Mar [ ] A r Ma Jun Jul[[X]A Se Oct Nov Dec Heating Jan Feb H H XMar [ ]Apr i May Jun Jul I i rirj [ ] Au Sep rj Oct Nov iA N HDec Ventin Jan Feb X Mar [ Apr May Jun Jul [[ ] Aug Se Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 .78 78 78 Heating (W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY RM Default(8lbs/sq.ft. ft2 ft 0.3 DINING RM Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING RM Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8lbs/sq.ft. ft2 ft 0.3 DEN CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 DEN Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 11/6/202011:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 { FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ftz ft 0.3 HALL 2 Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ftz ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ftz ft 0.3 HALL Default 8 Ibs/s .ft. ftz ft 0.3 CLST 3 11/6/2020 11:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7