Certification for Design Load Compliance
Project Name: Cory McCrary
Project Address: 4313 North 43rd St. Fort Pierce, FL 34946
Permit
Occupancy Type: S-1
Construction Type: 116
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2017 Code Sixth Edition with 20 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: X 1 II III IV Exposure Category: B X C D
4. Design Wind Velocity 150 mph X ASD LRFD End Zone Width: 3 ft
5. Mean Roof Height 13.25 ft Roof Pitch: 3 :12 Parapet: NA ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1:12/-25 Zone 2:15/-41 Zone 3: 18/-72 Zone 4: 25/-28 Zone 5: 28/-36 Garage: NA
7. Design Loads: Floor: NA PSF Roof/Dead: 15 PSF Roof/Live: 12 Balcony: NA PSF
Dock: NA PSF Deck: NA PSF Stairs: NA PSF Fence: NA PSF Railings: NA PSF
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 1500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Kent M. Bice
Signature, Date, and Seal
Print Name Cert # & Co. Cert Auth.
FL PE #: 50421 FL COA #: 30468
BBD Engineering & Design Firm, LLC 1552 6th St. SE, Winter Haven, FL 33880
Company Name & Address
Revised 12/07/2018