Loading...
HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Cory McCrary Project Address: 4313 North 43rd St. Fort Pierce, FL 34946 Permit Occupancy Type: S-1 Construction Type: 116 INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Code Sixth Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: X 1 II III IV Exposure Category: B X C D 4. Design Wind Velocity 150 mph X ASD LRFD End Zone Width: 3 ft 5. Mean Roof Height 13.25 ft Roof Pitch: 3 :12 Parapet: NA ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1:12/-25 Zone 2:15/-41 Zone 3: 18/-72 Zone 4: 25/-28 Zone 5: 28/-36 Garage: NA 7. Design Loads: Floor: NA PSF Roof/Dead: 15 PSF Roof/Live: 12 Balcony: NA PSF Dock: NA PSF Deck: NA PSF Stairs: NA PSF Fence: NA PSF Railings: NA PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 1500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Kent M. Bice Signature, Date, and Seal Print Name Cert # & Co. Cert Auth. FL PE #: 50421 FL COA #: 30468 BBD Engineering & Design Firm, LLC 1552 6th St. SE, Winter Haven, FL 33880 Company Name & Address Revised 12/07/2018