HomeMy WebLinkAbout530-STANDARD-OLIVER AUGER ANCHOR-SignedC/)
EACH 2'-0" BLOCK MUST BE
INSTALLED WITH (2) ROWS
OF 10d NAILS @ 3" O.C.
D
O
J
z
ATTACH BRACKET TO Q
STUD-.
STUD THRU HOLE IN
o
0
w
ANCHOR PLATE WITH p
0
3/8" 0 x 6" CARRIAGE C/)
N
BOLT AND LOCKNUT
—STUD
CORNER STUD
0
M
END WALL
SIDING
TRIM
ANCHOR BRACKET
TO BE FLUSH WITH
EDGE OF TRIM
BUILDING SIZE
QTY OF ANCHORS
UP TO 8X12
4
UP TO 10X15
4
ANCHORS INSTALLED AT EACH
CORNER OF THE BUILDING
AUGER ANCHOR COMPONENTS BY OLIVER TECHNOLOGIES
This item has been
electronically signed and
• PART NUMBERS:
sealed by Richard Wills, PE.
OT3644GPMP- 5/8" X 36" (36" IMBED) GALVANIZED AUGER
On the date shown below
OT17SWB - SIDEWALL BRACKET FOR USE WITH THRU BOLTS
using a Digital Signature.
REPORT NO. LO-FJ90129-A
Printed copies of this
-OR-
document are not considered
OT24SWBSIDEWALL BRACKET FOR USE WITH THRU BOLTS
signed and sealed and the
REPORT NO. LO-FJ90129-B
signature must be verified on
• WORKING LOAD FOR ANCHOR SYSTEM IS 3,150 LBS
any electronic copies.
WITH THE MAXIMUM LOAD OF 5,080 LBS
RDll�����//i
• THE ANCHORS MUST BE INSTALLED AND TESTED IN
ACCORDANCE TO THE MANUFACTURERS SPECIFICATIONS.
\.�`�xQ�GNA•ENsN�<<s'%��
2020 FLORIDA BUILDING CODE, 7TH EDITION, HVHZ
* No. 76835 ;
STATE OF
s/ONAL ENG��
I111111 m
29 JAN 2021
Scale: NTS CUSTOMERS NAME: Tuff Shed P.O.#:
TUFF SHED TitIe:AUGER ANCHOR DETAIL
Drawn By:PK
Storage Buildings & Garages FOR WIND SPEEDS
Date Drawn: 1 /14/21
Checked By:
UP TO 175 MPH
Date Revised: