Loading...
HomeMy WebLinkAbout530-STANDARD-OLIVER AUGER ANCHOR-SignedC/) EACH 2'-0" BLOCK MUST BE INSTALLED WITH (2) ROWS OF 10d NAILS @ 3" O.C. D O J z ATTACH BRACKET TO Q STUD-. STUD THRU HOLE IN o 0 w ANCHOR PLATE WITH p 0 3/8" 0 x 6" CARRIAGE C/) N BOLT AND LOCKNUT —STUD CORNER STUD 0 M END WALL SIDING TRIM ANCHOR BRACKET TO BE FLUSH WITH EDGE OF TRIM BUILDING SIZE QTY OF ANCHORS UP TO 8X12 4 UP TO 10X15 4 ANCHORS INSTALLED AT EACH CORNER OF THE BUILDING AUGER ANCHOR COMPONENTS BY OLIVER TECHNOLOGIES This item has been electronically signed and • PART NUMBERS: sealed by Richard Wills, PE. OT3644GPMP- 5/8" X 36" (36" IMBED) GALVANIZED AUGER On the date shown below OT17SWB - SIDEWALL BRACKET FOR USE WITH THRU BOLTS using a Digital Signature. REPORT NO. LO-FJ90129-A Printed copies of this -OR- document are not considered OT24SWBSIDEWALL BRACKET FOR USE WITH THRU BOLTS signed and sealed and the REPORT NO. LO-FJ90129-B signature must be verified on • WORKING LOAD FOR ANCHOR SYSTEM IS 3,150 LBS any electronic copies. WITH THE MAXIMUM LOAD OF 5,080 LBS RDll�����//i • THE ANCHORS MUST BE INSTALLED AND TESTED IN ACCORDANCE TO THE MANUFACTURERS SPECIFICATIONS. \.�`�xQ�GNA•ENsN�<<s'%�� 2020 FLORIDA BUILDING CODE, 7TH EDITION, HVHZ * No. 76835 ; STATE OF s/ONAL ENG�� I111111 m 29 JAN 2021 Scale: NTS CUSTOMERS NAME: Tuff Shed P.O.#: TUFF SHED TitIe:AUGER ANCHOR DETAIL Drawn By:PK Storage Buildings & Garages FOR WIND SPEEDS Date Drawn: 1 /14/21 Checked By: UP TO 175 MPH Date Revised: