Loading...
HomeMy WebLinkAbout211453-1d Compaction - signedHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 February 24, 2021 CONTRACTOR: JOB LOCATION: PERMIT #: To Whom it may concern, Tl C01 t ENGINEERING PO Box78-11377 L AND TESTING 78 ,I%LOP IL Phone: 12 C.A.# 5693 KSMengineering.net DiFrancesco Construction, Inc. 8840 Lonesome Pine Trail Ft. Pierce, FL. 34945 2302 Grand Oaks Avenue Ft. Pierce, Florida 2008-0337 KSM JOB # : 211453-1d/JM/ct Enclosed, please find the nuclear density test results performed on the compacted foundation fill for the garage at the above referenced project. Should you have any question, please feel free to contact our office. Respectfully, N IE'D���'i���i No. 81439 ".c A: �-A0 STATE OF � Rio /S/ONAL Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 02/24/21 Email to: difranconstinc@aol.com Digitally signed :diary I = by Bryan E Dahlke Date: 2021.02.24 15:02:29-05'00' Proudly Serving Florida since 1990 Headquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 DATE TESTED: PERMIT #: CONTRACTOR: JOB LOCATION: tl CP 1 t ENGINEERING i1171Vi AND TESTING SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 February 23, 2021 2008-0337 DiFrancesco Construction, Inc. 2302 Grand Oaks Avenue Ft. Pierce, Florida Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone:772-589-0712 C.A.# 5693 KS Meng ineering.net KSM JOB # : 211453-1d/JM/ct NUC If 215 Nuc Model: MC-IDR-P Nuc Serial #: MD80404215 ITEM TESTED: Compacted Foundation Fill for the Garage Pad TEST LOCATION PEN DRY MAX. DRY PERCENT # DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE (P.C.F.) COMPACTION 1 N.E. 12" 10 102.9 105.8 97.3% 2 S.E. 11 103.3 97.6% 3 Center 13 105.1 99.3% 4 S.W. 11 103.3 97.6% 5 N.W. 13 104.9 99.1% Soil Description: Brown Sand In Place Moisture: 17.8% Proctor Optimum Moisture: 13.0% Proctor Max. Dry Density: P.C.F. 105.8 @ Test Locations the Density & Penetrometer reading indicate the Degree of Compaction Meets Minimum Requirement for Staked Foundation Disclaimer: Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the Bryan E. Dahlke, P.E. tested area has been altered from the approved V.P. of Engineering inspected condition. PE # 81439 2/24/2021 Proudly Serving Florida since 1990 Headquarters1345 tl Cm- 1 t ENGINEERING U.S. Highway 1 PO Box 78-113777 Sebastian, FL. 32958 1 % 100 LVL AND TESTING Sebastian, FL. 3297 Orlando hone: 772 589-0712 723 Progress Way SOIL COMPACTION REPORT C.A.# 5693 Sanford, FL. 32771 ASTM D 1557 KS Meng ineering.net DATE TESTED: February 23, 2021 KSM JOB # : 211453-1d/1M/ct PERMIT #: 2008-0337 CONTRACTOR: DiFrancesco Construction, Inc. JOB LOCATION: 2302 Grand Oaks Avenue Ft. Pierce, Florida 107.0 I I I I I W E I I I I I I 106.0 -1—.._..-4.._.._1._.._..�.._..�.._.._. G I I I I I I H T 105.0—..—.. �..—..—� ..—.. ..—..—� I I I I I I ..—.. I P I I I I I I 104.0 T_.._...._.._�._.._..r ._...._.._�._.._..�.. ...._.._. C I I I I I I I F 103.0 J_.._..1.._.._l. _..L.._..1.._.._l._.._..L.._.. I I I I I I I p I I I I I 102.0 .._.. i.. _.I._.._..� .._.. i.._.._.._.._... .._.. I R Y I I I I I 101.0.._...._.._._..—...._....—..—{._.._..�..—...._.._. I I I I I I I I 100.0 ._.._.- .._.. 1._.._..� .._.. �.._.._, 8 9 10 11 12 13 14 15 16 Moisture - % of Dry Weight Soil Description: Brown Sand Proctor Optimum Moisture: 13.0% Proctor Max. Dry Density: P.C.F. 105.8 Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 2/24/2021 Proudly Serving Florida since 1990