Loading...
HomeMy WebLinkAboutDesign Calculations♦ SeaIs • •Easy easyseals.com DESIGN CALCULATIONS S FOR GOODYEAR FREESTANDING SIGN 6101 Orange Ave — Ft Pierce GENERAL NOTES: 1. Design is in accordance with the Florida Building Code 6th Edition (2017) for use within and outside the High Velocity Hurricane Zone (HVHZ). 2. Wind loads have been calculated per the requirements of ASCE 7-10 as shown herein, except where noted otherwise. 3. These engineering calculations pertain only to the structural integrity of those systems, components, and/or other construction explicitly specified herein and/or in accompanying engineering drawings. The existing host structure (if any) is assumed to be in good condition, capable of supporting the loaded system, subject to building department approval. No warranty, either expressed or implied, is contained herein. 4. System components shall be as noted herein. All references to named components and installation shall conform to manufacturer's or industry specifications as summarized herein. 5. Where site conditions deviate from those noted herein, revisions may be required or a separate site -specific engineering evaluation performed. 6. Aluminum components in contact with steel or embedded in concrete shall be protected as prescribed in the 2015 Aluminum Design Manual, Part 1-A. Steel components in contact with, but not encased in, concrete shall be coated, painted, or otherwise protected against corrosion. 7. Engineer seal affixed hereto validates structural design as shown only. Use of this specification by contractor, et. Al, indemnifies and saves harmless this engineer for all costs & damages including legal fees & apellate fees resulting from deviation from this design. Index: Pg 1 Cover Pg 2 Wind Loads Pg 3 Footing Design Pg 4 Primary Support(s) ;;gi�t01111111111, � •��r �4,ra; valid • % No. 3 2 — �� •� S AT e ��••Ic� V� ®���� Cht'iSr��18CIi�YY1F:1L'��,RE�# 67382 Easy SdM9#1,nnfie! Auth # 31124 1200 N Federal Hwy, #200 Boca Raton, FL 33432 Easy Seals .com Page 1 EasySeals CALCULATIONS FOR FREESTANDING SIGNS easysealscom ASCE 7-10 Design Wind Loads FREESTANDING SOLID SIGNS AND WALLS (AT GRADE) Building Specs V = 150 mph Basic wind speed Exposure C Calculations a = 9.5 3-sec gust speed power law exponent zg = 900, Nominal ht. of atmos. boundary layer G = 0.85 150 mph - UP "C" Monuments at grade W/Ht Ratio <_ 0.5 DESIGN SIGN WIND HEIGHT PRESSURES 15 ft ± 32.9 psf 18 ft + 34.1 psf 20 ft + 34.9 psf 30 ft + 38.0 psf 35 ft + 39.3 psf 40 ft + 40.4 psf 45 ft + 41.4 psf 50 ft + 42.3 psf 55 ft + 43.2 psf 60 ft + 44.0 psf 70 ft + 45.4 psf 80 ft + 46.7 psf 90 ft + 47.9 psf 100 ft + 49.0 psf 110 ft + 50.0 psf 120 ft + 50.9 psf 130 ft + 51.8 psf 140 ft + 52.6 psf 150 ft + 53.3 psf 175 ft + 55.1 psf 200 ft + 56.7 psf 250 ft I ± 59.4 psf Risk Category 1 Structure ASD Load Combo Coeff: 0.6 Kd = 0.85 Directionality factor Kzt = 1.0 Topographic factor Cf = 1.55 Force Coefficient ...Width/Height ratio >_ 0.5 N Y n Y qZ 0.85 24.9 0.88 25.9 0.90 26.5 0.98 28.9 1.01 29.8 1.04 30.7 1.07 31.4 1.09 32.1 1.12 32.8 1.14 33.4 1.17 34.5 1.21 35.5 1.24 36.4 1.27 37.2 1.29 37.9 1.32 38.6 1.34 39.3 1.36 39.9 1.38 40.5 1.42 41.8 1.46 43.0 1.53 45.1 Page 2 Edsy Seals CALCULATIONS FOR FREESTANDING SIGNS �„ easyseals.mm Footing Design for Freestanding Signs Structure Dimensions & Loading Design wind pressure: P = Overturning Safety Factor: S2 = Sign area 1: Al Height of applied force above grade: h1= Sign area 2: A2 = Height of applied force above grade: h2 = Overturning Moment: 32.9 psf 1.5 ... FBC 1807.2.3 80.0 sq ft ... tributary area 1 for each footer (e.g. sign) 5.0 ft ... height of area 1 centroid 0.0 sq ft ... tributary area 2 for each footer (e.g. post) 0.0 ft ... height of area 2 centroid Mn = P*(A1*h1+A2*h2) Mn = 13.1 kip-ft Sq / Rect Footing dimensions: B = 5.08 ft L = 4.08 ft Footing depth: d = 2.5 ft Soil cover: ds = 0 ft Superstructure weight: Dr = 200 lb Soil cover weight: Ds = 0 lb ...=100pcf*B*L*ds Footing weight: Df = 7772 lb ... = 150pcf*B*L*d Total weight: D = 7972 lb ... = Dr+ Ds + Df Soil Strength ... FBC Tables 1806.2, 1819.6 Soil class: 4. Sand, silty sand, silty gravel Lateral bearing strength: Plat = 150 psf/ft Vertical bearing strength: Pbrg = 2000 psf Check Vertical Soil Bearing Pressures e = 1.65 ft ... = (P)*(A1*h1+A2*h2) / D qtoe = 2*D/[3*L*(B/2-e)) ...reaction below footer at toe qtoe = 1461 psf Resisting moment due to Dead Load: My = D*13/2 My = 20.2 kip-ft Total Resisting Moment: Mtot = My / .Q Mtot = 13.5 kip-ft ... > B/6 qtoe < Pbrg OK Mtot > Mn OK Page 3 Seals EasyCALCULATIONS FOR FREESTANDING SIGNS earyS "Wm ' Hollow Structural Rectangular Tubing in Bending Allowable Stress Design per 2010 AISC Spec for Structural Steel Buildings Material Properties Yield Stress, A500 Grd B Steel: Modulus of Elasticity: Member Properties Flange: b = Flange Thickness: tf = Web: d = Web Thickness: tw = Fy = 46 ksi E = 29000 ksi 6 in 1/4" = 0.233" 6 in 1/4" = 0.233" Safety Factor = 1.67 Per Section 63.4 Moment of Inertia: Ix = Section Modulus: S = Deflection Limit: DO = End Supports: Cantilever 29.8 in 9.9 in L/80 Design wind pressure: P = 32.9 psf Sign area: A1= 80.0 sq ft ... tributary area for each post (e.g. sign+post) Eccentricity of applied force: e1= 5.0 ft ... distance to area centroid (weighted avg h1,h2) Unbraced Length: Lc = 5.0 ft Check for Limiting Width -Thickness Ratios Flanges b/t = 23.8 = (b-2*t2)/t1 1.12*v(E/Fy) = 28.1 Flange Compact Limit 1.40*v(E/Fy) = 35.2 Flange NonCompact Limit Flanges are compact (Compact/Noncompact, per Table 84.1) Webs d/t = 23.8 2.42*v(E/Fy) = 60.8 5.70*d(E/Fy) = 143.1 Webs are compact = (d-2*t1)/t2 Web Compact Limit Web NonCompact Limit (1): Yielding Limit State This criteria applies to all members, compact and noncompact Mn = Fy*S Mallow = Mn / 1.67 Mn = 456.7 kip -in Mallow = 273.5 kip -in Check Member Bending Allowable Moment: Mn = 273.5 kip -in Minimum of Mallow values above Moment in member: Mmax = P*A1*e1 Mmax = 157.7 kip -in Check Member Deflection: Allowable Deflection: Dauow = 0.75 in L / 80 Deflection in member: Amax = P*(A*e^3) / (3*E*I) Amax = 0.22 in Mmax < Mn ... OK Amax < Aallow ... OK Page 4