HomeMy WebLinkAboutTANK SPECS - 2-25-21 9ML
Quality Steel Corporation AG/UG Propane Tanks
OVERALL LENGTH
OVE
NEIGIf
-4
LEG SPACING
LM WOTH
1450 w9. AND UP
APPROXIMATE ABOVEGROUND/UNDEGROUND(AG/UG)VESSEL DIMENSIONS AND SPECIFICATIONS
WATER DIAMETER HEAD OVERALL OVERALL LEG* LEG** WEIGHT **QUANTITY
CAPACITY (OD) TYPE LENGTH HEIGHT WIDTH SPACING (tbs.) FULL LOAD PER STACK
"
*120 wg. 24" Ellip. 5'-8" 2'-101/2
3' 1'-11/2" or 3�_/2 260 109196 16112
*250 wg. 30" Heml. 7'-10" 3'-8" 1'-S" 4'-11" 480 54 9
*320 wg. 30" Hemi. 9'-7" 3'-8" V-5" 5' 620 45 9
500 wQ. 371/2" Hemi. 10' 4'-2" 114" 5' 950 37 130 8 1 6
1000 wg. 41" Hemi. 16' 4'--5" 11-8" 30'-1" 1,800 17115 6 1 5
1450 wg. 461/2" Ellip. 17'-V 4'-11" 1'-9" 11'-7" 2,650 12 4
1990 w 461/2" Ellip. I 23'-IV I 4'--11" V-9" 16' 3,520 8 4
0imenslons and spe ifkatlons shown are apprandnMe.Individual vessels may wary.
'Leg spacing+/-r.Leg widths and Sparing may vary based on mfg.location.Check with your salesperson for details.120,2S0,320 wg.stamAard tanks
-mo holes in legs(one cents hole an request).500 and 10M w&standard tanks-2 holes 160 an center.1450 w&and up as shown above.
'•Fall load and stack quandtles vary by shipping location.Check with your salesperson for details.
General Specifications
-Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels,Section Vlll,Division 1.
Complies with NFPA 58.
-Rated at 2S0 psig from-20°F to 125"F. All vessels registered with National Board.
-Two service options available:
Option 1:Ready-to-bury underground option,coated with either powder coated phenolic epoxy finish
or liquid applied epoxy primer coat followed by urethane top coat,supplied with composite
AG/UG dome.
Option 2:Aboveground option,coated with either powder coated TGIC polyester finish or liquid
applied epoxy primer coat followed by urethane top coat,supplied with steel AG/UG dome.
-All vessels are shipped vacuum pre-purged to enable simplified first fill of the vessel.
Updated June 30,2015
l
r «
0 OW
AW
DOW
• ./'���t� �• `�,,•�•:•,!� •,7.3
•�i I.;
J!
J.
Ali
WKS
i •
'••r N
t
�. . � m� t
t
INCL
ti
' �r A
V•
' - PROPANE CONSTRUCTION NOTES
s
1. All pipe and fittings above ground and inside building shall be
SCH..40 Galvanized ASTM A120 or AGA approved_corrugated
stainless steel•(C•S.S.T.) pipe. ,
2. All.polypipe and finings shall be ASTM D251.3 or ASTM D2517
and shah be b gdeil-outside underground at a depth of 18" with
warning tape and tracer wire.
3. All pipe and meter locations are approximate and subject to -
change.- '
.4. All polypipe shall be Joined by heat fusion or approved mechanical.
couplings.
5. All'galvanized pWe shall be threaded.
6. Alf.pipeL shall be pressure tested to 20 PSI for a period of 24
hours. .