HomeMy WebLinkAboutBuilding Plansa¢a _ REPAIR of South Wall Existing Residence DAMAG r SOUTH9309 Indian River Dr, Fort Pierce, FL WORK A ii s- Mark & Brooke Fick -- KEY HOUSE PLAN ® o 1. THE QUALITY OF LUMBER AND THE DESIGN FOR LOAD SUPPORTING 11. THE NUMBER AND SIZE OF NAILS CONNECTING WOOD MEMBERS MEMBERS SHALL CONFORM TO THE STANDARD: 'NATIONAL DESIGN SHALL NOT BE LESS THAN THOSE SET FORTH IN TABLE 2306.3.1 OF FLORIDA SPECIFICATION FOR STRESS GRADE LUMBER AND ITS FASTENINGS', BUILDING CODE ALL NAILS SHALL BE COMMON NAILS U.O.N. ALL NAILS LATEST EDITION. USED FOR EXTERIOR WAUL/ROOF FRAMING SHALL BE HOT —DIP GALVANIZED. 2. MINIMUM LUMBER GRADE SHALL BE AS FOLLOWS: 12. ALL. BOLTS SHALL BE GALVANIZED STANDARD MACHINE BOLTS WITH MALLEABLE TIMBER GREATER THAN THAN 5' THICK S1P, 20% m.c., 11 WITH fb v 1500 IRON OR GALVANZED STEEL PL WASHERS WHEN HEAD OR NUT BEARS ON pa! LEDGERS, HEADERS, JOIST SYP, 19X m.c., /2 WITH fb — varies w/she WOOD. HOLES FOR BOLTS SHALL BE DRILED WITH A BIT 1/32' LARGER THAN NOMINAL BOLT DIAMETER. TIGHTEN ALL BOLTS BEFORE PLASTERING. BEAMS, BLOCKING, PLATES, ETC. D BRACING od �%24OOtb( 13. LAG BOLTS AND SCREWS SHALL BE PREDRILLED. THE DIl OF PREDRILLED TRUSSES:TRD SYYPSYP� 191E m.c., HORDS)5 (WEBS) HOLES SHALL BE 6OX OF SHANK DIAMETER. THE THREADED PORTION OF THE SCREW SHALL BE INSERTED BY TURNING WiTH A WRENCH, NOT BY 3. WOOD IN CONTACT WITH MASONRY, CONCRETE OR EXPOSED TO DRIVING WITH A HAMMER PENETRATION OF THREADED PORTION SHALL WEATHER TO BE PRESSURE TREATED. BE 7 DIAMETERS MINMNM. 4. PLYWOOD SHALL MEET THE REQUIREMENTS OF THE LATEST EDITION 14. NO STRUCTURAL MEMBER SHALL BE CUT WITHOUT THE APPROVAL OF OWNER OF U.S. PRODUCT STANDARD P.S.L. AMERICAN PLYWOOD ASSOCIATION. & ARCHITECT OF RECORD. ANY CUTTING, NOTCHING OR BORING OF WOOD ROOF DIAPHRAGMS SHAL BE STRUCTURAL 1, C—D EXTERIOR GRADE. SHALL CONFORM TO THE LOCH. BUILDING CODE 15. ALL HARDWARE CONNECTING WOOD MEMBERS SHALL BE RECESSED WHEN 6. NOT USED REQUIRED BY ARCHITECTURAL FINISH. VERIFY WITH ARCHITECTURAL DRAWINGS. 7. NOT USED 16 ALL WOOD CONNECTIONS INDICATED BY SIMPSON STRONG TIE UNLESS S. NOT USED . OTHERWISE NOTED. USP, SEMCO OR OTHER MANUFACTURERS MAY BE 9. NOT USED SUBMITTED IF THEY ARE EQUAL OR BETTER IN CAPACITIES, INCLUDING UPUFr, LATERAL AND GRAVITY LOADS. 10. WHERE ROOF DECK Iq 5/ " CDX PLYWOOD PLYWOOD SHALL BE PLACED IN 4x8 AS MUCH A§ POSSIBLE. WITH LONGDIMENS (FULL FACE )PJWEIS TO SPAN ACROSS F PANELS, PUR 17. ALL FXfiRIOR FRAMED WALLS &SHEAR WALLS SHALL BE 2x8 AT 16' O.C. AND SHALL BE SHEATHED WITH MIN. 1/2' PLYWOOD NAILED WITH 10d NAILS PROVIDENS BEIWEELNRTRRUSSSES ALONG LONG EDGES OED WHEN PANELS ARE ATTACHED DIRECTLY TO TRUSS/ RAFTER. ATTACH WITH AT 6' O.C. ALONG ALL EDGES & 12' O.C. AT INTERMEDIATE SUPPORTS TYP. WITH 10d DEFORMED SHANK NAILS AT 6' O.C. AT ALL PANEL EDGES AND AT 12' D.C. AT INTERMEDIATE SUPPORTS. CURRENT VIEW --DAMAGED SOUTH WALL WITH TEMPORARY PATCH LEGAL DESCRIPTION SEC 19/20 TWNSHP 36S. RANGE 41E- 157.76 FT OF N 251 FT OF S 1/2 OF SE 1/4 OF SEC 19, LYG E OF FEC RR AND S 157.76 FT OF N 251 FT OF FRACTIONAL SEC 20 - LESS SR 707-665/1505; AS RECORDED IN PUBLIC RECORDS OF ST LUCIE COUNTY, FLORIDA PARCEL ID: 3519-441-0002-000-1 PROJECT DESCRIPTION. DEMO THE EXISTING DAMAGED SOUTH WALL OF EXISTING RESIDENCE, RECONSTRUCT THE WALL TO CURRENT CODES AND RESTORE THE FINISHES TO MATCH EXISTING. DRAWING INDEX AO.1 COVER DRAWING INDEX, PHOTOS & NOTES A2.1 DEMOLITION PLAN A3.1 REBUILD FLOOR PLAN A4.1 BUILDING ELEVATION A5.1 WALL SECTION & DETAILS 1 \1 V11L 11W L• CODE ANALYSIS: ATWOOD Applicable Code References: ARCHITECT Florida Building Code - Building 2020 Graphic Designer Florida Building Code - Residential 2020 Florida Buildinging Code - Plumbing 2020 LIC. f AR 0013444 Florida Building Code - Electical 2020 & NEC 2020 Florida Building Code - Existing 2020 i wl Pierce, F134982 Building Type: EXISTING RESIDENCE 407-304-0264 read8dm1■p vd c= Project Description: REPAIR SOUTH WALL Classification of Work: Level 1 Chpt 6 & 7 Classif.of Hazard of Contents: Ordinary Hazard Occupancy Classification: Residential: _ SINGLE FAMILY LIVING AREA (CONDITIONED) = 2333t S.F. Carport & Porches = 935 s.f. Existing under roof = 3309 s.f. Construction Classification: FBC Table 500: TYPE VI: UNPROTECTED / UNSPRINKLERED Maximum area allowed= 7,000 s.f. Maximum no. stories = 2 Maximum Height = 40 ft. Drawing idle: ,010 ( - 0334, 764.vC4� COVER R E V I E WNED F 0R DRAWING INDEX CODE C V L11PANCO NOTES & PHOTOS ST. LUCIE COUNTY., Drawn BY - rea B0 Checked By - PLAN NOTES: Prat No.: 1. WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE 20-008 OVER SCALE DIMENSIONS. Contractors shall verify and be responsible for dimensions and field scaie- conditions of job. NTS 2. Not Used 3. Dimensions (Exterior) from face of masonry or concrete, issue Date) to face of wall sheathing on stud, and (Interior) face of wall — 4-2 flnlsh to stud wall finish unless otherwise noted. Studs assumed to be nom. 4' interior & 6" exterior wall LION 4. Door head heights shall be 6'—B" unless otherwise Drawft No. - noted (UON). 5. Window unit designations are based on typical n aluminum single hung units. A 1/2' sin Iin�® j'J AO.1 unit is recommended. A comparable ai aleeunit by various manufacturers may be ed as long as the required wind load presures are ceritified In compliance. 6-At51- "N(. FAAmCro WAU-- GYP IN 5irie - tUl �� cn rwrm- Lowae- - )6 1 J Ie' 'r, 0 Waja -To f !fie �r�i i i r En� 2.P( ro J6s7 50OF;�ii1ci Ul:-,TA iL L 2x& 6-rV0 6 OACY-- 7w,p 5akm -4 FT* (PRV arr WA111 TO 1011a 2 x 6 a rftja5� VAO-, POST 4 BeAm @ �3d' tln� Twin 5� l b f wmw- NORK AREA II II Ij II DEMO EXI5TING NOA NIP► I I FRAME YVALL DOOR GJ�C.T 6 tD3�J �� ATWOOD y ARCHITECT Graphic Designer LIC. # AR 0013444 Fort Pierce, FI 34982 407-304-0264 Y o U L 0 y LLI -mow �a) U Q IL N �J Mo rn1 Drawing Title: Demo Plan Drawn BY rea Checked By. Project No.: 20-008 Scale: 1/4"=1'-0" Issue Date: 1-14-21 Drawing No.: LE COPY A2.1 N OVO aQa NOTES: The south Wall is only load bearing for the Gable end and roof overhang. DEMOLITION: 1. Demo Interior wall finish as required (max up to 8'-0"+/-) 2. Remove wall insulation 3. Shore up wall/ roof (refer to detail on A-1) 4. Remove the temporary plywood closure panels 5. Remove all damaged stucco as required — probably just above 8 ft AFF. 6. Remove all damaged sheathing- probably just above 8 ft AFF 7. Remove damaged studs, Cut off lower damaged portion & retain upper portion of studs to sister new studs and attach. 8. And Remove damaged base plate, retain anchor bolts if possible to anchor new PT plate. RECONSTRUCTION: 1. Install new dbl. PT 2x base plate anchored into concrete slab @ 4'-0" O.C. max with existing anchor bolts and/or 5/8"x9" epoxy anchor bolts with min. 6" embedment. 2. Install new studs @ 16" o.c. with Simpson connectors (RSP-4) to bottom plate and Sister new studs to remaining studs with 3-16d nails at 12". And frame out openings. Use Simpson Msta18 at headers. 3. Install R-19 insulation into entire wall. 4. Install new 5/8 " CDX sheathing- nailed with 8d galv. Nails @ 6" intermediate and edge. Do Not cutout framed openings —This will be done in future work. 5. Apply Vapor Barrier—Tyvek or equal. And flashing at corners around all openings. 6. Install Metal lathe securely anchored to sheathing w/ galy. Staples. 7. Apply 3 coat stucco and paint with elastomeric coating. 8. Install new / replacement windows. Or install temporary plywood filler. 9. Install batt insulation in wall—(R-19 or min. R-11) 10. Install replacement interior wall finish (1/2" Gyp. Bd. Do not spackle joints NORK AS 0 I N 0 I ATWOOD ARCHITECT Graphic Designer LIC. # AR 0013444 Fort Pierce, FI 34982 407-304-0264 U °mow � U 0 �:�iW o 0 (D"Z Q:� ::E If Drawing Title: PROPOSED Reconstruction Plan Drawn BY rea Checked By. Project No.: 20-008 Scale: 1/4"=V-0" Issue Date: 1-14-21 Drawing No.: � ®py AW EXIST — INSULATION 1 /2" GYP. BD. TYP. INTERIOR TOP PART 1 WALL SECTION A5.1 eCAL.E 1 1- r - T-0' EXIST. OVERHANG VENTED R-25 INSUL. IN JOIST SPACING & R-13 ON TOP OF PLYWOOD UNDER THE GABLE ROOF (TOTAL R-38f) EXISTING 2X PLATE ANCHORED TO OUTRIGGER FRAMING 24"O.0 REPLACE R-19 INSULATION AS REQUIRED EL~ Q V) J .U) Z X w O � I � N U) NEW 1/2" GYP. BD. TYP. INTERIOR AS REQUIRED 6" STUD @ 16"O.C. ANCHORED AT BOTTOM PLATE W/ SIMPSON RSP4 AND SISTER — AT TOP W/ 3—ROWS 3-16D NAILS ® 12" O.C. BOTTOM PART z WALL SECTION A5.1 acme r TT-0' DOUBLE PT 2X6 PLATE ON CONC. W/1 /2" EPDXY BOLTS ® 48" EXISTING CONCRETE — SLAB '-0" AFFf a a a d R-19 INSUL. IN 2X6 FRAME WALL TYP. v` RICHARD E. ATWOOD ARCHITECT Graphic Designer UC. 4 AR ODIN" Orlando, Florida 32W4 4M-628-M FAX- AW-628-M2 RE —INSTALL 3 COAT W L LL—L STUCCO ON METAL V O LATHE ON VAPOR BARRIER BUILDING W -0 Cd WRAP � � � � Cr Drawing Title PROPOSED WALL SECTION EXISTING GRADE Drawn By rea Checked By. Project No: 20-008 Scale: 1-1 /2"=19-0" leave Date; 1-14-21 Drawing No.- Fig @'���►5.1