Loading...
HomeMy WebLinkAboutNOA; Residential Hurricane Resistant WindowsMIAMI•QADE ® PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RE11805 SW 26 Street Room 208 BOARD AND CODE ADMINISTRATION DIVISIONR) Miami, Florida 33175-2474 T (786) 315-259U F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) • �w miamidade eov/economy Seres Glass Block, Inc. 10576 Broadview Road Broadview Heights, OH 44147 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below.The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Residential Hurricane Resistant Windows with THICKSET® 90 Series Glass Block and ProVantagel Silicone System APPROVAL DOCUMENT: Drawing No. RHRWA01, titled "Residential Hurricane Resistant Windows with TMCKSE14 90 Series Glass Block and ProVantage® Silicone System", sheets 1 through 4 of 4, dated 11/17/2015, with revision A dated 06/27/2018, prepared by the manufacturer, signed and sealed by Hermes F. Norero, P.E. on 07/12/2018, bearing the Miami -Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 17-0821.14 and consists of this page i and evidence pages E-1, E 2 and E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. C MADE-COUNlY NOA No.18-0725.06 Expiration Date: December 1, 2020 Approval Date: September 6, 2018 ., 1:7 Page 1 Seves Glass Block Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBIVIITTED L Evidence submitted under- previous NOAN A. DRAWINGS "Submitted tinder NOA # 1S-1201.12" I. Drawing No. RARW-001, titled "Residential Hurricane Resistant Windows with THICKSET 90 Series Glass Block and KWIK'N EZ Silicone System", sheets I through 3 of . 3, dated 11/17/2015, prepared by the manufacturer, signed and sealed by Hermes F. Norero, P.E. B. TESTS "Submitted under NOA # 1 S-1201.12" 1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC, TAS 202-94 along with marked -up drawings and installation diagram of Residential Hurricane Resistant Windows with THICKSET 90 glass block and KWIK'N EZ Silicone System", prepared by Intertek/Architechn-9 Testing, Inc., Test Report No. F0556.01-501.18, dated 11/17/2015, signed and sealed by Joseph A. Reed, P.E. "Submitted under NOA # 04-0301.01 " 2. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per .FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 along with marked -up drawings and installation diagram of Series/Model. 8" x 8" x 4" THICKSET 90 glass block assembly", prepared by Architectural Testing, .Inc., Test Report No. 01-44639.03, dated 12/02/2003, signed and sealed by Joseph A. Reed, P.E. C. CALCULATIONS "Submitted under NOA # 15-1201.12" 1. Anchor calculations prepared by Building Drops, Inc., dated 12/08/2015, signed and sealed by Hermes F. Norero, P.E. "Submitted under-NOA # 12-0406.05" 2. Anchor calculations prepared by Building Drops, Inc., dated 04/03/2012, signed and sealed by Hermes F. Norero, P.E. "Submitted under NOA # 04-030.1.. 01 " 3. Calculations prepared by Engineering Analytics, Inc, sheets I through 4, of Thickset Series Fasteners, dated 05/02/2005, signed and sealed by Carol D. Hays, P.E. Carlos M. Utrera, P.E. Product Control Examiner NOA No.18-0725.06 Expiration Date: December 1, 2020 Approval Date: September 6, 2018 E-1 5eves Glass Block, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No.14-0909.11, issued to Cardinal Systems, Inc., for their Rigid PVC Extrusions for Glass Block, approved on 12/11/2014 and expiring on 12/01/2020. F. STATEMENTS "Submitted under NOA # IS-1201.12" 1. Statement letter of code conformance to the 51h edition (2014) of the FBC and of no financial interest, issued by Building Drops, dated 12/08/2015, signed and sealed by Hermes F. Norero, P.E. "Submitted under NOA # 12-0406.05" 2. Statement letter of code conformance to 2010 FBC and no financial interest, issued by Building Drops, dated 04/03/2012, signed and sealed by Hermes F. Norero, P.E. 2. Evidence submitted under NOA # 17-0821.14 A. DRAWINGS 1. Drawing No. RHRW-001; titled "Residential Hurricane Resistant Windows with THICKSET' 90 Series Glass Block and ProVanSilicone System", sheets 1 through 3 of 3, dated 11/17/2015, prepared by the manufacturer, signed and sealed by Hermes F. Norero, P.E. on 12/19/2017. B. TESTS 1. None. C. CALCULATIONS 1. Product Evaluation Report No. 4742, prepared by Building Drops, dated 04/12/2017, signed and sealed by Hermes F. Norero, P.E. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of code conformance to the a Edition (2017) FBC issued by Building Drops, dated 12/15/2017, signed and sealed by Hermes F. Norero, P:E. 2. Testing schedule letter issued by Intertek, dated 12/08/2017, signed by Vicki L. McElwain. 3. Agreement and bill of sale dated 08/24/2016. 4. Declaration of the ownership dated 12/0112016. ,4 4o i: ?V-7 Carlos M. Utrera, P.E. Product Control Examiner NOA No. 18-0725.06 Expiration Date: December 1, 2020 E-2 Approval Date: September 6, 2018 Seves Glass Block, Inc NOTICE OF ACCEPTANCE: EVIDENCE SU13NMTED 3. New evidence submitted A. DRAWINGS 1. Drawing No. RHRW-001, titled "Residential Hurricane Resistant Windows with THICKSET' 90 Series Glass Block and ProVantageo Silicone System", sheets 1. through 4 of 4, dated 11/17/2015, with revision A dated 06/27/2018, prepared by the manufacturer, signed and sealed by Hermes F. Norero, P.E. on 07/12/2018. B. TESTS 1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of Thickset 90 Series (4" thick) and Glass Block Windows, prepared by Intertek, Test Report No. H8798.01- 109-18, dated 06/04/2018, signed and sealed by Joseph A. Reed, P.E. C. CALCULATIONS 1. Anchor calculations prepared by Building Drops, Inc., dated 06/27/2019, signed and sealed by Hermes F. Norero, P.E. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. None. G. OTHERS 1. Test proposal No. 17-0913. Carlos M. Utrera, P.E. Product Control Examiner NOA No.18-0725.06 Expiration Date: December 1, 2020 E-3 Approval Date: September 6, 2018 SEVES GLASS BLOCK PLAN RIGID PVC PLASTIC CHANNEL STRUCTURE* 8x8x4 SEVES GLASS BLOCK THICKSET 90 ► — NOON■■ NOON■■ Emmmmm Emmmmm NOON■■ i 8x8x4 SEVES GLASS BLOCI THICKSET 90 STRUCTURE* PERIMETER FRAMING SEALANT LOCATIONS GLASS BLOC SEALANT LO RIGID P' CHANNI PRE -PUNCHED HOL SECTION ELEVATION IMPACTRESISTANT DESIGN PRESSURE RATING 6 BLOCKS x 6 BLOCKS ± 100.0 PSF * SEE ANCHOR SCHEDULE, SHEET 4 ) PVC PLASTIC SPACER PERIMETER FRAMING SEALANT LOCATIONS (LENGTH OF CHANNEL) .. No MEN mmmmmml NONE■■ ONEENE NONEE■ mmmmmm MOOSE■ mmmmm■ mmmmm■ mmmmmm mmmmmm NOON■■ REVISIONS REV DESCRIPTION DATE A SIZES ADDED PER NEW TESTING 6/27/18 SEVES GLASS BLOCK PLAN RIGID PVC PLASTIC CHANNEL STRUCTURE * 8x8x4 SEVES GLASS BLOCK THICKSET 90 NOMINAL WIDTH SECTION ELEVATION IMPACT RESISTANT 6 BLOCKS x 12 BLOCKS DESIGN PRESSURE RATING ± 80.0 PSF TIME Residential Hurricane Resistant Windows With THICKSET0 90 Series Glass Block asRomply, g with the Florida ,N - .��' And ProVantage® Silicone System Building Code NOA-No. 18-0725.06 Expiration Date 12/0112020 Miami -Dad Product Control 73778 — SEVES GLASS BLOCK, INC. r � ' * 10576 BROADVIEW ROAD rE OF BROADVIEW HEIGHTS, OH 44147 ••i''�� ��� SCALE DWG. N0. 112" =1'-0" RHRW-001 - BY LMS DATE 11/1712015 1 SHEET 10F 4 ItEV A SEVES GLASS BLOCK PLAN RIGID PVC PLASTIC CHANNEL STRUCTURE* 8x8x4 SEVES GLASS BLOCK THICKSET 90 A III 1111 111111 MINIMIMINIMEMIM� 0■■■■■■■■■ MINIMIN MIMIMIMIMIMMIIMM111IIII MINIMIMMISIMEM111 MIMINIMMIMISIMEIf EMINIMEM ME EMIMMISIMMINIM F-00 MAXIMUM SECTION NOMINAL WIDTH ELEVATION IMPACTRESISTANT 9 BLOCKS x 12 BLOCKS DESIGN PRESSURE RATING 168.0 PSF REVISIONS REV DESCRIPTION DATE I A I SIZES ADDED PER NEW TESTING 1 6/27118 1 SEVES GLASS BLOCK 8x8x4 SEVES GLASS BLOCK PLAN RIGID PVC PLASTIC CHANNEL STRUCTURE * THICKSET 90 a. MENOMONEE MENEEMENE1 MEMINIMINIMMIN F-04 MAXIMUM P1 P\/OTIOM 9 BLOCKS x 9 BLOCKS SEE ANCHOR SCHEDULE, SHEET 4 SECTION IMPACT RESISTANT DESIGN PRESSURE RATING 168.0 PSF TITLE Residential Hurricane Resistant Windows PRODUCT REVISED .�•''c ..•S� .��With THICKSET® 90 Series Glass Block as complying with the Florida . 0 Building Code = 7377 ' And ProVantage® Silicone System NOA-No. -- 18-0725.06 Ex nation a 12/01I2020 = ST T a' rr SEVES GLASS BLOCK, INC. By ORIOP.•� ��' ' 10576 BROADVIEW ROAD �s•••.. �� BROADVIEW HEIGHTS, OH 44147 Miami-D d Product Control i ` roA'L�^+ `\e� SCALE „= ' 11 DWG. NO. HER S<9.11QVY& 1/2 1-0 RHRW-001 FLowDAP,E 3na 39B E. DANIA BEACH BM., STE.3W FBPECERT.OFAMORIZAPONNO.2W8 DANIA BEACH, FL 33OD4BY LMS DATE 11/17/2015 SHEET $OF 4 STRUCTURE' SEVES SILICONE SEALANT, TYP. SEVES SILICONE —� SEALANT, TYP. Y� THICK SEVES SILICONE SEALANT, TYP. SEVES SILICONE — SEALANT, TYP. ANCHOR LOCATION (ANCHORS ARE STAGGERED 6y" O.C.) �L �l Cn a RIGID PVC PLASTIC CHANNEL (SEE "CHANNEL AT HEAD DETAIL') 8x8x4 SEVES GLASS BLOCK THICKSET 90 SEVES SILICONE SEALANT, TYP. SEVES SILICONE SEALANT, TYP. SEVES SILICONE SEALANT, TYP. SEVES SILICONE SEALANT, TYP. STRUCTURE' RIGID PVC PLASTIC SPACER ' SEE ANCHOR SCHEDULE, SHEET 4. TYPICAL HEAD DETAIL SCALE: 3" = T-0" 3.258 0.175 —F C� to NOTE: TYPICAL WALL THICKNESS = 0.035 PVC SPACER (NO. QP-0514 ) CARDINAL SYSTEMS, INC. SCALE 1:1 TYPICAL SILL DETAIL 8x8x4 SEVES GLASS BLOCK THICKSET 90 0.100 SEVES SILICONE �— SEALANT, TYP. N 0 RIGID PVC PLASTIC — SPACER 0.125 3.875 0 un 4.125 PVC CHANNEL (NO. QP-0477) CARDINAL SYSTEMS, INC. SCALE 1:1 SCALE: 3" = V-0" RIGID PVC PLASTIC SPACER 8x8x4 SEVES GLASS BLOCK THICKSET 90 RIGID PVC PLASTIC CHANNEL �2u U coC/3 ANCHOR LOCATION (ANCHORS ARE STAGGERED 6V O.C.) X. (MAX %" SHIM SPACE) SEVES SILICONE SEVES SILICONE SEALANT, TYP. SEALANT, � STRUCTURE' �x TYPICAL JAMB DETAIL SCALE: 3" = V-0" REVISIONS REV DESCRIPTION DATE I A I SIZES ADDED PER NEW TESTING 1 6127/18 1 ANCHOR LOCATION (ANCHORS ARE STAGGERED OF O.C.) RIGID PVC PLASTIC CHANNEL PRODUCT REVISED E as complying with the Florida ` N 377$ di O Building Code NOA-Ho. 18-0725.06 ; 7k Expiration Da 12I0112020 T • Q: MlaMl-D product Control � NEsIF�tB �aRIbAPE�lrrtt7 398 E. DAM A BEACH BLVD., STE. 338 ANCHOR LOCATION EXTERIOR SIDE) SEVES SILICONE SEALANT, TYP. PERIMETER CHANNEL, AT HEAD, TO BE CUT LENGTHWISE DOWN THE CENTER FOR INSTALLATION OF LAST ROW OF GLASS BLOCK. HALF CHANNEL PIECE THAT IS SECURED WITH SCREWS, SHOULD BE ON THE EXTERIOR SIDE. y" BEAD OF SEALANT APPLIED HORIZONTALLY ACROSS THE TOP INSIDE CORNERS OF CHANNEL HALVES. CHANNEL AT HEAD DETAIL SCALE 112" =1" Residential Hurricane Resistant Windows With THICKSET® 90 Series Glass Block And ProVantage0 Silicone System SIEVES GLASS BLOCK, INC. 10576 BROADVIEW ROAD BROADVIEW HEIGHTS, OH 44147 SCALE DWG. NO. VARIES RHRW-001 BY LMS I DATE 11117/2015 1 swu 3 OF 4 PEV A SPECIFICATION NOTES: GLASS BLOCK UNITS: Thickset 0 90 Series 8"x8"x4" or TxVx4" (nominal size). • FRAME AND SPACERS: Extruded white rigid PVC. Frame comers are cut square or mitered and are silicone sealed. Extruded by Cardinal Systems, Inc. • SEALANT: Seves Glass Block Sealant. One part neutral fast curing structural silicone sealant • SEALANT LOCATIONS: All horizontal and vertical glass block joints; inside comers of perimeter channels; two beads (2" from each edge) between back of perimeter channels and framing members; two beads each above and below "long" horizontal spacer and "short° vertical spacers; perimeter joints between glass block and channel legs; and perimeter joints between channels and framing members. • REINFORCEMENT: PVC spacers between all horizontal and vertical joints. Spacers in channels are not required. • SHIM SPACES: MaximumYa" shim space between the.pedmeter channel and wood frame. • FIELD INSTALLATION: Loose materials (glass block, spacers, channels and sealant) are available from Seves Glass Block authorized distributors, dealers and home centers for on -site installation. Complete window units, framed within 2x6 treated lumber, and pre -fabricated by Seves Glass Block in accordance with these instructions, are also available from authorized distributors, dealers and home centers. NOTE: These windows are recommended for RESIDENTIAL APPLICATIONS ONLY. ANCHORAGE SCHEDULE SUBSTRATE MATERIAL DATA FASTENER SPACING MIN. EMBEDMENT (E) MIN. EDGE DISTANCE (E.D.) STEEL MIN,18 GA. 910-16 HWH ITW TEK 2" FROM CORNER, 3 THREADS PENETRATION Y4' fy = 33 KSI SCREW GR. 5 (FLAT HEAD) 6,y2" O.C. BEYOND STEEL FRAMING CONCRETE MIN. f3000 PSI %s"0 HILTI KWIK CON II+ 2" FROM CORNER, 1" 1 Y" (FLAT HEAD) 6Y" Q.C. %6"0 ITW TAPCONS 2" FROM CORNER, 1" 2" " O-C- MASONRY CONFORMS TO ASTM C90 Y16 0 HILT] KWIK CON p+ 2" FROM CORNER, 1" 1 Y" GROUT CONFORMS TO (FLAT HEAD) W2" O.C. ASTM C476 MIN, GROUT Ys°0 ITW TAPCONS 2° FROM CORNER, 1" 2 " F� = 2000 PSI " O.C. WOOD MIN. S.G. = 0.55 #8 WOOD SCREW. 2" FROM CORNER, 1-1/2" /n (FLAT HEAD) 6Y" O.C. SEVES GLASS BLOCK SERIES PATTERN NOMINAL DIM. MIN, FACE THICKNESS THICKSET® 90 NUBIOS, 8"4"x4" 6"x6"x4" 0.75 IN. 0.75 IN. THICKSET® 90 CLARITY® 8"0x4" 6"x6"x4" 0.75 IN. 0.75 IN. THICKSET® 90 ENDURAO 8"x8"x4" 0.75 IN. REVISIONS REV DESCRIPTION DATE A I SIZES ADDED PER NEW TESTING I 6/27/18 1 sE . F Residential Hurricane Resistant Windows o With THICKSET® 90 Series Glass Block PRODUCT REVISED as complying with the Florida N . 778 1 — And ProVantage® Silicone System Building Code 7k NOA—No. 18-0725.06 — TE OF Expiration Date 12101/2020 �O -' F ? . J SEVES GLASS BLOCK, INC. �. 10576 BROADVIEW ROAD By , S "••••''••�G;`�•` BROADVIEW HEIGHTS, OH 44147 Miam ciProduct Control L/ SCALE DWG. NO. REV FLORIDAP.E.NO. 73778 NTS RHRW-001 A M I- MANIA BEACH BLVD- STE. 338 DANIA BEACH. FL 33004 BY LMS DATE 11117/2015 SHEET 4 OF 4 FBPE CERT. OF AUTHORIZATION NO.28578