Loading...
HomeMy WebLinkAboutProduct Approval; Horizontal SliderThe ,,)me Depot Special Ordei',.,,uote Customer Agreement #: H0222-113812 Customer: MARK FICK Address: 13931 AMBER LANE MONTGOMERY, TX 77316 Phone 1: 936-443-3403 Phone 2: 936-443-3403 Email: TWINOAKS@SUDDINLINK. NET Printed Date:1/22/2021 Store: 0221 Associate: ANGELA Address: 3451 NW FEDERAL HWY JENSEN BEACH, FL 34957 Phone: 772-692-9000 Pre -Savings Total: $590.15 Total Savings: ($0 n0) Pre -Tax Price: $590.15 :All prices are subject to change. Customer is responsible for verifying product selections. The Home Depot will not accept returns for the below products. i'`�`�RECEIi/EEa FFB1011 Permitting a='aartment St, Lucie county Catalog Version -195 Frame Width = 351/2" Frame Height = 351/2" Sash Split = Even Divide mill NEW. T t�LYG,iYWGr ss`yV� •,'w.'-.�.,suasIIQ,'n.hE�v.•xxe ,. m. +.r�• �. of •. ,o ff glow r 4'i :e. ^3 Fn:.iu.a sfi 'iei$ FT9•'" `^`.� '' e� }.,. 71?Qk%.... y .,+s $ ,. i� `� �'�. c;�4 `".'N x �,$3ii8 OJ,. d.a.r " 1� .'lk. 6 �.,d'•e Premium Atlantic Vinyl, Single Slider, 35.5 x 35.5 Assembly = Full Unit, Regional Compliance = FBC-HVHZ--NAMI, Impact Rating = Large Missile Impact, Rating = DP+50/-55, Installation & Frame Type = Nail Fin, Operation = XO (Left Hand) Prame Color - Exterior = White, frame Color- Interior = White Select Size Type = Standard and Custom Sizes, Measurement Type = Net Frame Size, Frame Width = 35 1/2", Frame Height = 351/2", Vent Division = Even Divide, Vent Width =17.75 Energy Efficiency = Other glass options, Begin Line 100 Description -- Line 100-1 — Soundmaster = Standard - No Soundmaster, Glazing = Insulated, Low-E = tow-E 366, Neat Glass = No, Glass Color/Texture = Clear, Glass Type = impact, Inner Glass Type = impact, Outer Glass Type = Standard, Select Impact Interlayer Type = PVB, IG Options = None, Select Glass Thickness = 5/16 in - 3/16 out Grid Type = No Grids Screen = Screen, Select Screen Options = Standard Screen Frame, Select Screen Mesh Type = Fiberglass Mesh, Screen Mesh Finish = Charcoal Mesh Lock Type = Style Cam Lock(s), Number of Locks = 2 Locks, End Line 100 Description Hardware Finish - Interior = White Does Unit Meet Egress Req.? = Does Not Meet Egress Installation Accessories = None, Interior Frame Options = None, Extension Jamb = None Prep for Mull = No Mull Prep, Prep for Shipping = None - FL #=14090.4, a U-Factor= 0.36, Solar Heat Gain Coefficient = 0.23, Visible Light Transmittance = 0.5, Condensation Resistance = 50, CPD# = JEL-A-707-02075-00013 Room Location =, Is This a Remake = No, Specific information = None v v ? i F� N yProdua Approval ' , USMU Public User j\ S-j PrOCIUCt Approval"1 >> Aupgratlan Application Type MkR� ' x tti i�$a<d. Code Version 2020 ApplicationApproved *Approved DBPR. ApprovalsDBPR shall be reviewed and ratified by the POC and/or the Commission If necessary. Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Emall Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Product Approval Method Date Submitted Date Validated C3 ]ELD-WEN 3737 Lakeport Blvd Klamath Falls, OR 97601 (800) 535-3936 fbcl@jeld-wen.com Rylee Sumner Frisks fbcl@Jeid-wen.cam 3ELD-WEN Corporate Customer Service 3737 Lakeport Blvd. Klamath Falls, OR 97601 (800) 535-3936 customerserviceagents@jeld-wen.com RECMED FFH 0 8 2021 PefHtUng Department -tt. W, tie Cuixndy Windows Horizontal Slider Certification Mark or Listing National Accreditation & Management Institute National Accreditation & Management Institute Standard TAS 201 TAS 202 TAS 203 Method i Option A 11/18/2020 11/19/2020 Year 1994 1994 1994 https://floridabuilding.org/pr/pr app_dtl.aspx.param=wGEVXQwtDgtGLR%2byCBy1Jndy... 2/4/2021 Date Pending FBC Approval Date Approved 11/24/2020 Summary of Products FL # Model, Number or Name Description 14090.1 Premium Atlantic Vinyl Horizontal Slider (8200) 74" x 62" Insulated Glass (3/16 In - 3/16 out Annealed) Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14090 R12 C CAC N1011635-R1.Ddf Approved for use outside HVHZ: Yes Quality Assurance,Contract Expiration Date Impact Resistant: No 07/31/2025 Design Pressure: +50/-55 Installation Instructions Other: Windows with insulated glass units wider than 36" FL14090 R12 II DP50-55 74x62 Installation Instructions.odf Verified By: Hermes Norero, PE 73778 require setting blocks. Laminated glazing intedayer material requirements meet the current edition of the FBC Created by Independent Third Party: Yes In accordance with Miami -Dade NOR for DuPont Evaluation Reports SentryGlas and DuPont PVB interlayers. FL14090 R12 AE PER3105.Ddf Created by Independent Third Party: Yes 14090.2 Premium Atlantic Vinyl Horizontal Slider (8200) 74" x 54" Insulated Glass (3/16 In - 3/16 out Annealed) Limits of Use Certification Agency Certificate Approved for use In HVHZ: Yes FL14090 R12 C CAC NI011636-111,odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 07/31/2025 Design Pressure: +65/-70 Installation Instructions Other: Windows with insulated glass units wider than 36" FL14090 R12 II OP65-70 74x54 Installation Instructions odf Verified By: Hermes Norero, PE 73778 require setting blocks. Laminated glazing intedayer material requirements meet the current edition of the FBC Created by Independent Third Party: Yes In accordance with Miami -Dade NOA for DuPont Evaluation Reports SentryGlas and DuPont PVB interlayers: FL14090 R12 AE PER3102.pdff Created by Independent Third Party: Yes 14090.3 Premium Atlantic Vinyl Horizontal Slider (8200) 74" x 62" Insulated Glass (5/16 SGP Lam in - 3/16 Annealed out) Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14090 R12 C CAC NI011681-RI.Ddf Approved for use outside HVHZ: Yet Quality Assurance Contract Expiration Date Impact Resistant: Yes 08/30/2025 Design Pressure: +50/-55 Installation Instructions Other: Windows w/ IG units wider than 36" require FL14090 R12 11 DP50- setting blocks. These windows do not meet small missile 55 LMI 74x62 installation Instructions. Of Impact wind-borne requirements of the current edition of Verified By: Hermes Norero 73778 the FBC when the exterior lite is annealed, they do meet Created by independent Third Party: Yes small missile Impact wind-borne protection requirements Evaluation Reports when the exterior lite is tempered. Laminated glazing FL14090 R12 AE PER3103.Ddf interiayer material requirements meet the current edition Created by Independent Third Party: Yes of the FBC in accordance w/ Miami -Dade NOA for DuPont SentryGlas and DuPont PV8 interlayers. 14090.4 Premium Atlantic Vinyl Horizontal Slider (8200) 74" x 54" Insulated Glass (5/16 PVB Lam in - 1/8 Annealed out) Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14090 R12 C CAC N1011745-R1.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 10/31/2025 Design Pressure: +50/-55 Installation Instructions Other: Windows w/ IG units wider than 36" require FL14090 R12 1I DP50- setting blocks. These windows do not meet small missile 55 74x54 LMI Installation Instructions.Ddf. impact wind-borne requirements of the current edition of Verified By: Hermes Norero, PE 73778 the FBC when the exterior lite Is annealed; they do meet Created by Independent Third Party: Yes small missile Impact wind-borne protection requirements Evaluation Reports when the exterior lite is tempered. Laminated glazing EL14090 R12 AE PER 3101.01' Intedayer material requirements meet the current edition Created by Independent Third Party: Yes of the FBC in accordance w/ Miami -Dade NOA for DuPont SentryGlas and DuPont PV8 interlayers 114090.5 ( Premium Atlantic Vinyl Horizontal Slider (8200) 74" x 54" Insulated Glass (5/16 SGP Lam in - 1/8 Annealed out) Limits of Use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-65 Other: Windows w/ IG units wider than 36" require setting blocks. These windows do not meet small missile impact wind-borne requirements of the current edition of the FBC when the exterior lite is annealed, they do meet small missile impact wind-borne protection requirements Certification Agency Certificate FL14090 R12 C CAC NI011682-R1.Ddf Quality Assurance Contract Expiration Date 08/30/2025 Installation Instructions Verified By: Hermes Norero, PE 73778 Created by Independent Third Party: Yes Evaluation Reports hups.//floridabufl(ling.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgtGLR%2byCBylJndy... 2/4/2021 1 WI MW WIx Or cox.) I TYPICAL ELEVATION WITH FASTENER SPACING Installation Notes: 1. Seal flange/frame to substrate. 2. Use #10 PH or greater fastener though the nail fin with sufficient length to penetrate a minimum of 1 1/20 into the wood framing. For 2X wood frame substrate (min. S.G. = 0,42). Host structure (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads to the structure. The host structure is the responsibility of the architect or engineer of record for the project of installation. Digitally signed by Hermes F. Norero, P.E. Reason: I am approving this document Date: 2014.03.13 06.45:17-04'00' 'hls schedule addresses only the fasteners required to anchor the t t t I I I���� Window to achieve the rated design pressure up to the size limitations ,oI � i� oted. It is not intended as a guide to the installation process and does of address the sealing consideration that may arise in different wall �% F ��� �Q �.►'' onditlons. For the complete installation procedure, see the instructions the window or to 7 ackaged with go :ww.jeld-wen.com/resourcesriinstallaton. .SCLAIMER: T 7 �' ��� •''• OP' its drawing and its contents are confidential and are not to be produced or copied in whole or in part or used or disclosed to others see Opt as authorized by JELD-WEN Inc., �p 1 1 U21 MIN. EMBEDMENT I 2X WOOD FRAME i MM OrSTANCE FOR FOR ED6E:3/43/4' v4" MAX sHIM SPACE MM m {-22A 3.0 3.0 mm BITE mm %— Dow 9" AMM bErAIL FRAME SECTION (TYP) VERTICAL SECTION MM DISTANCE FOR EDGE 3/4" V2" Mm EMBEDMENT MIN. DISTANCE FOR EDGE: 3/4" 2X WOOD FRAME 11/2" MIN. EMBEDMENT NAIL FIN INSTALLATION JAMB SECTION QVP) HORIZONTAL SECTION NOTE OvAbotam WILM AM994 Wood CPWd% . Max Frame I OP RATINGI IMPACT 74 x 54 +50/-55 1 ' YES General Notes: 1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria of the adopted international Building Code(IBC), the Intemationai Residential Code(IRC); the Florida Building Code(FBC) including HVHZ and the industry requirement for the stated conditions. 2. All glazing shall conform to ASTM E1300. 3. At minimum, glazing shall be 3 mm annealed / 11 mm airspace 13 mm annealed 12 mm PVB by Dupont / 3 mm annealed. . 4. Use structural or composite shims where required. 5. Installation methods can be In within the same opening. 6. An Impact protective system is not required where wind bome debris protection is mandated by local building code. 7. Maximum size's are buck sizes and do not Include fin or flange. i PROJECT ENGINEER: DATE' / 2014 3737 Lakeport Blvd Igamath Falls, OR. 97601 DRAWN BY: D. Vezo SCALE: NTS iL�N Phone: (541) 882-3451 .�. * = CHECKED BY: J. Kantola TITLE: Premium Atlantic Vinyl Impact Horizontal Slider APPROVED BY: L Z. Nail Fin Installation (74" x 54") ya• �� 9 330 IDENTIFIER No. I AIM 101 n-3R96-1-FRC PLANT NAME AND LOCATION: CAD DWG. No.: I I REV: SHEET 1 of 4