HomeMy WebLinkAboutProduct Approval; Horizontal SliderThe ,,)me Depot Special Ordei',.,,uote
Customer Agreement #: H0222-113812
Customer: MARK FICK
Address: 13931 AMBER LANE
MONTGOMERY, TX 77316
Phone 1: 936-443-3403
Phone 2: 936-443-3403
Email: TWINOAKS@SUDDINLINK.
NET
Printed Date:1/22/2021
Store: 0221
Associate: ANGELA
Address: 3451 NW FEDERAL HWY
JENSEN BEACH, FL 34957
Phone: 772-692-9000
Pre -Savings Total: $590.15
Total Savings: ($0 n0)
Pre -Tax Price: $590.15
:All prices are subject to change. Customer is responsible for verifying product selections. The Home Depot will not accept returns for the below products.
i'`�`�RECEIi/EEa
FFB1011
Permitting a='aartment
St, Lucie county
Catalog Version -195
Frame Width = 351/2"
Frame Height = 351/2"
Sash Split = Even Divide
mill
NEW.
T t�LYG,iYWGr ss`yV� •,'w.'-.�.,suasIIQ,'n.hE�v.•xxe ,.
m. +.r�• �.
of
•. ,o ff
glow r 4'i
:e. ^3 Fn:.iu.a sfi 'iei$ FT9•'" `^`.� '' e� }.,. 71?Qk%.... y .,+s
$ ,. i� `� �'�. c;�4 `".'N x �,$3ii8 OJ,. d.a.r " 1� .'lk. 6 �.,d'•e
Premium Atlantic Vinyl,
Single Slider,
35.5 x 35.5
Assembly = Full Unit,
Regional Compliance = FBC-HVHZ--NAMI,
Impact Rating = Large Missile Impact,
Rating = DP+50/-55,
Installation & Frame Type = Nail Fin,
Operation = XO (Left Hand)
Prame Color - Exterior = White,
frame Color- Interior = White
Select Size Type = Standard and Custom Sizes,
Measurement Type = Net Frame Size,
Frame Width = 35 1/2",
Frame Height = 351/2",
Vent Division = Even Divide,
Vent Width =17.75
Energy Efficiency = Other glass options,
Begin Line 100 Description
-- Line 100-1 —
Soundmaster = Standard - No Soundmaster,
Glazing = Insulated,
Low-E = tow-E 366,
Neat Glass = No,
Glass Color/Texture = Clear,
Glass Type = impact,
Inner Glass Type = impact,
Outer Glass Type = Standard,
Select Impact Interlayer Type = PVB,
IG Options = None,
Select Glass Thickness = 5/16 in - 3/16 out
Grid Type = No Grids
Screen = Screen,
Select Screen Options = Standard Screen Frame,
Select Screen Mesh Type = Fiberglass Mesh,
Screen Mesh Finish = Charcoal Mesh
Lock Type = Style Cam Lock(s),
Number of Locks = 2 Locks,
End Line 100 Description
Hardware Finish - Interior = White
Does Unit Meet Egress Req.? = Does Not Meet
Egress
Installation Accessories = None,
Interior Frame Options = None,
Extension Jamb = None
Prep for Mull = No Mull Prep,
Prep for Shipping = None
- FL #=14090.4, a
U-Factor= 0.36,
Solar Heat Gain Coefficient = 0.23,
Visible Light Transmittance = 0.5,
Condensation Resistance = 50,
CPD# = JEL-A-707-02075-00013
Room Location =,
Is This a Remake = No,
Specific information =
None
v
v ?
i
F� N
yProdua Approval
'
, USMU Public User
j\ S-j
PrOCIUCt Approval"1 >> Aupgratlan
Application Type
MkR� '
x tti i�$a<d.
Code Version
2020
ApplicationApproved
*Approved DBPR. ApprovalsDBPR shall be reviewed and ratified by
the POC and/or the Commission If necessary.
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Emall
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Product Approval Method
Date Submitted
Date Validated
C3
]ELD-WEN
3737 Lakeport Blvd
Klamath Falls, OR 97601
(800) 535-3936
fbcl@jeld-wen.com
Rylee Sumner Frisks
fbcl@Jeid-wen.cam
3ELD-WEN Corporate Customer Service
3737 Lakeport Blvd.
Klamath Falls, OR 97601
(800) 535-3936
customerserviceagents@jeld-wen.com
RECMED
FFH 0 8 2021
PefHtUng Department
-tt. W, tie Cuixndy
Windows
Horizontal Slider
Certification Mark or Listing
National Accreditation & Management Institute
National Accreditation & Management Institute
Standard
TAS 201
TAS 202
TAS 203
Method i Option A
11/18/2020
11/19/2020
Year
1994
1994
1994
https://floridabuilding.org/pr/pr app_dtl.aspx.param=wGEVXQwtDgtGLR%2byCBy1Jndy... 2/4/2021
Date Pending FBC Approval
Date Approved 11/24/2020
Summary of Products
FL #
Model, Number or Name
Description
14090.1
Premium Atlantic Vinyl
Horizontal Slider (8200) 74" x 62" Insulated Glass (3/16 In -
3/16 out Annealed)
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL14090 R12 C CAC N1011635-R1.Ddf
Approved for use outside HVHZ: Yes
Quality Assurance,Contract Expiration Date
Impact Resistant: No
07/31/2025
Design Pressure: +50/-55
Installation Instructions
Other: Windows with insulated glass units wider than 36"
FL14090 R12 II DP50-55 74x62 Installation Instructions.odf
Verified By: Hermes Norero, PE 73778
require setting blocks. Laminated glazing intedayer
material requirements meet the current edition of the FBC
Created by Independent Third Party: Yes
In accordance with Miami -Dade NOR for DuPont
Evaluation Reports
SentryGlas and DuPont PVB interlayers.
FL14090 R12 AE PER3105.Ddf
Created by Independent Third Party: Yes
14090.2
Premium Atlantic Vinyl
Horizontal Slider (8200) 74" x 54" Insulated Glass (3/16 In -
3/16 out Annealed)
Limits of Use
Certification Agency Certificate
Approved for use In HVHZ: Yes
FL14090 R12 C CAC NI011636-111,odf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
07/31/2025
Design Pressure: +65/-70
Installation Instructions
Other: Windows with insulated glass units wider than 36"
FL14090 R12 II OP65-70 74x54 Installation Instructions odf
Verified By: Hermes Norero, PE 73778
require setting blocks. Laminated glazing intedayer
material requirements meet the current edition of the FBC
Created by Independent Third Party: Yes
In accordance with Miami -Dade NOA for DuPont
Evaluation Reports
SentryGlas and DuPont PVB interlayers:
FL14090 R12 AE PER3102.pdff
Created by Independent Third Party: Yes
14090.3
Premium Atlantic Vinyl
Horizontal Slider (8200) 74" x 62" Insulated Glass (5/16 SGP
Lam in - 3/16 Annealed out)
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL14090 R12 C CAC NI011681-RI.Ddf
Approved for use outside HVHZ: Yet
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
08/30/2025
Design Pressure: +50/-55
Installation Instructions
Other: Windows w/ IG units wider than 36" require
FL14090 R12 11 DP50-
setting blocks. These windows do not meet small missile
55 LMI 74x62 installation Instructions. Of
Impact wind-borne requirements of the current edition of
Verified By: Hermes Norero 73778
the FBC when the exterior lite is annealed, they do meet
Created by independent Third Party: Yes
small missile Impact wind-borne protection requirements
Evaluation Reports
when the exterior lite is tempered. Laminated glazing
FL14090 R12 AE PER3103.Ddf
interiayer material requirements meet the current edition
Created by Independent Third Party: Yes
of the FBC in accordance w/ Miami -Dade NOA for DuPont
SentryGlas and DuPont PV8 interlayers.
14090.4
Premium Atlantic Vinyl
Horizontal Slider (8200) 74" x 54" Insulated Glass (5/16 PVB
Lam in - 1/8 Annealed out)
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL14090 R12 C CAC N1011745-R1.odf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
10/31/2025
Design Pressure: +50/-55
Installation Instructions
Other: Windows w/ IG units wider than 36" require
FL14090 R12 1I DP50-
setting blocks. These windows do not meet small missile
55 74x54 LMI Installation Instructions.Ddf.
impact wind-borne requirements of the current edition of
Verified By: Hermes Norero, PE 73778
the FBC when the exterior lite Is annealed; they do meet
Created by Independent Third Party: Yes
small missile Impact wind-borne protection requirements
Evaluation Reports
when the exterior lite is tempered. Laminated glazing
EL14090 R12 AE PER 3101.01'
Intedayer material requirements meet the current edition
Created by Independent Third Party: Yes
of the FBC in accordance w/ Miami -Dade NOA for DuPont
SentryGlas and DuPont PV8 interlayers
114090.5 ( Premium Atlantic Vinyl Horizontal Slider (8200) 74" x 54" Insulated Glass (5/16 SGP
Lam in - 1/8 Annealed out)
Limits of Use
Approved for use In HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +60/-65
Other: Windows w/ IG units wider than 36" require
setting blocks. These windows do not meet small missile
impact wind-borne requirements of the current edition of
the FBC when the exterior lite is annealed, they do meet
small missile impact wind-borne protection requirements
Certification Agency Certificate
FL14090 R12 C CAC NI011682-R1.Ddf
Quality Assurance Contract Expiration Date
08/30/2025
Installation Instructions
Verified By: Hermes Norero, PE 73778
Created by Independent Third Party: Yes
Evaluation Reports
hups.//floridabufl(ling.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgtGLR%2byCBylJndy... 2/4/2021
1 WI MW WIx Or cox.) I
TYPICAL ELEVATION WITH FASTENER SPACING
Installation Notes:
1. Seal flange/frame to substrate.
2. Use #10 PH or greater fastener though the nail fin with sufficient length to penetrate a minimum of 1
1/20 into the wood framing. For 2X wood frame substrate (min. S.G. = 0,42).
Host structure (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads
to the structure. The host structure is the responsibility of the architect or engineer of record for the
project of installation.
Digitally signed by Hermes F. Norero, P.E.
Reason: I am approving this document
Date: 2014.03.13 06.45:17-04'00'
'hls schedule addresses only the fasteners required to anchor the
t t t I I I����
Window to achieve the rated design pressure up to the size limitations
,oI
� i�
oted. It is not intended as a guide to the installation process and does
of address the sealing consideration that may arise in different wall
�%
F
��� �Q �.►''
onditlons. For the complete installation procedure, see the instructions
the window or to
7
ackaged with go
:ww.jeld-wen.com/resourcesriinstallaton.
.SCLAIMER:
T 7 �'
��� •''• OP'
its drawing and its contents are confidential and are not to be
produced or copied in whole or in part or used or disclosed to others
see
Opt as authorized by JELD-WEN Inc.,
�p
1
1 U21 MIN. EMBEDMENT I
2X WOOD FRAME i
MM OrSTANCE FOR
FOR ED6E:3/43/4'
v4" MAX
sHIM SPACE
MM
m {-22A
3.0 3.0 mm
BITE
mm
%— Dow 9"
AMM bErAIL
FRAME SECTION (TYP)
VERTICAL SECTION
MM DISTANCE
FOR EDGE 3/4"
V2" Mm EMBEDMENT
MIN. DISTANCE
FOR EDGE: 3/4"
2X WOOD
FRAME
11/2" MIN.
EMBEDMENT
NAIL FIN INSTALLATION
JAMB SECTION QVP)
HORIZONTAL SECTION
NOTE OvAbotam WILM AM994 Wood CPWd% .
Max Frame I OP RATINGI IMPACT
74 x 54 +50/-55 1 ' YES
General Notes:
1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria
of the adopted international Building Code(IBC), the Intemationai Residential Code(IRC); the Florida
Building Code(FBC) including HVHZ and the industry requirement for the stated conditions.
2. All glazing shall conform to ASTM E1300.
3. At minimum, glazing shall be 3 mm annealed / 11 mm airspace 13 mm annealed 12 mm PVB by
Dupont / 3 mm annealed. .
4. Use structural or composite shims where required.
5. Installation methods can be In within the same opening.
6. An Impact protective system is not required where wind bome debris protection is mandated by local
building code.
7. Maximum size's are buck sizes and do not Include fin or flange.
i
PROJECT ENGINEER:
DATE'
/ 2014
3737 Lakeport Blvd
Igamath Falls, OR. 97601
DRAWN BY:
D. Vezo
SCALE:
NTS
iL�N
Phone: (541) 882-3451
.�.
* =
CHECKED BY:
J. Kantola
TITLE:
Premium Atlantic Vinyl Impact Horizontal Slider
APPROVED BY:
L Z.
Nail Fin Installation (74" x 54")
ya•
��
9 330
IDENTIFIER No. I
AIM 101 n-3R96-1-FRC
PLANT NAME AND LOCATION:
CAD DWG. No.:
I
I REV:
SHEET
1 of 4