Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Engineering
BUILDING'S PEAK ROOF HEIGHT vs DESIGN IWND PREs M FOR COAMNEWS A• CLADDING (81F.) FOR ASCE 7-/6 - PEAK ROOF HEIGHT LESS THAN OR EQUAL TO 60 BASIC WIND SPEED - 170 mph RISK CATEGORY H BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS& COMMERCIAL BUILDINGS(RETAIL, WHOLESALE) PPS L-LESS THAN 7'-9' L-GREATER OR EQUAL THAN 7'-9"AND L••GREATER OR EQUAL THAN 12'-J" ROOF LESS THAN J2'-J' HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.O. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.O. ULTIMATE A.S.D. ULTIMATE A.S.O. * INDICATED DESIGN WIND PRESSURES 0'- 15, 76.4 45.3 102.4 61.4 7J.0 43.8 95.5 57.3 68.5 41.1 86.4 51.8 CORRESPOND TO THE MAXIMUM END , ZONE AND INTERIOR ZONE CONDITIONS > 15'-20' 80.4 48.2 1076 64.6 76.8 46.1 .100.4 60.2 72.0 43.2 90.8 54.5 AND FOR ALL ROOF >20'-25' 83.6 50.2 111.9 67.1 79.8 479 104.4 62.6 74.8 44.9 94.4 56.6 SLOPES. , >25=Jo' 86.2 51.7 115.5 69.3 82.4 49.4 107.7 64.6 77.3 46.4 974 58.4 **L ACCORDION=STORM HUTTTLENER BLADE LENGTH OR BAHAMA >Jo'-4o' 90.7 54.4 121.4 72.8 B6.6 52.0 113.3 68.0 81.2 48.7 102.4 61.4 SHUTTER HEIGHT. >4Q'-so' 94.3 56.6 126.2 75.7 90.0 54.0 7 177 70.6 84.4 50.6 106.5 63.9 *** PRODUCTS WHICH BEAR A >50'-60' 97.3 58.4 130.3 78.2 92.9 55.7 727.5 72.9 87.2 52.3 109.9 65.9 MIAMI-DAOE COUNTY OR A STATE OF FLORIDA APPROVAL MWING'Q PEAK ROOF HEIGHT •= DESIGN WIND PRESSURE FOR COMPONENTS AV CLADDING. (P.S.F,,) FOR ASCE 7-16 - PEAK ROOF HEIGHT GREATER THAN 60 FEET aI' BASIC WIND SPEED = 170 mph RISK CATEGORY ll BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS& COMMERCIAL BUILDINGS(RETAIL, WHOLESALE) toof ,60 �E�c PEAK L••LESS THAN 12-3" L"GREATER OR EQUAL THAN t2'-3' REVIEWED FOR ¢¢¢��� ROOF ���� ��� HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE BODE COMPLIANCE . (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.O. ULTIMATE A.S.D. 69 Yd� >60'-70' 91.5 54.9 167.7 100.6 84.3 50.6 148.4 89.0 ST. LU C I E COUNTY BUILDING SCHEMATIC > 70'-80' 93.6 56.2 171.E 1 1030 86.2 51.7 151.9 91.1 BOC<D`Q/� >80'-9o, 95.6 574 175.2 1 105.1 88.0 52.8 155.0 93.0 >9O'- too' 973 58.4 178.4 7074 89.7 53.8 157.9 94.7 ZI > too'- 120' 100.5 60.3 184.2 710.5 92.5 55.5 163.0 978 `� R1t1��1I����7�4 SCANNED > 120 - 140' 103.2 61.9 189.2 113.5 95.1 57.1 167.4 100.4 �.�� A.T'/ 7 ,_^(`{�qvj /f 1�� M ,^-, > too - /6o' 105.6 63.4. 193.E 1162 97.3 59.4 171.9 104.8 `�yaP�'••'��ENS•''•;��P��.�- b/r,�{�, FJ\\�II1M (rl��'i""�,�, ;�160;-.180' 7078 f 64.7-:�j 797.6 h`1.18'6•s"' 99.3 59.6 174.9 704.9 \' F tj L!):.,cv{J > 180 -200' 109.8 65.9 20 I.3 120.8 101.1 60.7 1 178.1 106.9 No.44167 ' >200'-250' 114.1 68.5 209.2 125.5 105.2 63.1 185.1 111.1 _*; *• ;'k >250'-J00' 1178 70.1 216.0 129.6 108.5 65.1 191.1 114.7 ?-o'•• STATE OF >Joo'-J5o' 121.0 72.6 221.9 133.1 )11.5 66.9 196.3 117.8 ? •, ,'��` >J50'-400' 123.9 74.3 2271 136.3 114.1 68.5 200.9 1 120.5 >400'-450' 126.4 75.8 231.8 139.1 116.5 69.9 205.1 1 12J.I >450,-Soo' 1 .8 77.3 236.1 141.7 118.6 71.2 208.9 125.3 28 HI l.)THIS CERTIFIED SIGNED AND SEALED WIND LOAD CHART,PREPARED BY THIS ENGINEER,BASED ON ASCE 7-16•FOR A BASIC WINO SPEED OF 170 MPH,AND 2020(7th EDITION)FLORIDA BUILDING CODE-BROWARD,PALM BEACH,MARTIN,,Sr. LUCIE&INDAN RIVER COUN77ES APPLICABLE RISK CATEGORY BUILDING&EXPOSURES,IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT. 02020 TlcttcO,INC - ASCE 7-16/ WIND PRESSURE CHART M.P 2.)'TNIS WHO LOAD CHART MUST BE SIGNED,SEALED AND DATED BY THIS ENGINEER IF USED TO OBTAIN A'ONE TIME BUILDING PERMIT. STORM PANELS ACCORDION&BAHAMA SHUTTERS."* DRAWN BY 3.)CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELECTION OF DESIGN WIND PRESSURE BASED ON THIS GENERIC WIND LOAD CHART. RISK CAT. If SLOGS 0612512020 WIND PRESSURES ARE ULTIMATE AND A.S.D.PRESSURES. 1 L E C O 1 N C. WIND PRESSURE CHART DATE 4.)THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS. TILLIT TESTING&ENGINEERING COMPANY 4ST,T N.R.4ev.6r.Sb.40l.VRcva caeDTNS a.xlfee BASIC WIND SPEED= 170 mph 20-117 5.)DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPARED BY vAon.:(wlfen-IS14.F,:(S61f4T1-f31r EXPOSURE D,Kd=0.85 THE CONTRACTOR OR PERMIT HOLDER(.p.,SPREADSHEET,OPENING SCHEDULE/TAKE OFF SHEET ETC.). C4-0006719 DRAWING No WALTER A.NLLlT Jr.P.E. "�R' ^�rrBN•' wrt m.x. ooemna ars FLOR/DA L'c.p 44167