Loading...
HomeMy WebLinkAboutPA FL9777-R13r _N4 , Business6CLA a Professional i i Regulation jigMI _ _ BCIS dome i Lcq In i user Registration HotTopics Submit Surcharge Stars ik Facts { Publications Contact Us � BCiS Site Map links Search Product Approval (A dNr USER: Public User Product Aooroval Menu > E duet or Application SL,%Mh> AncHrAtion List > Application Detail ■ ""'y Fi_ # Application Type FL9777-R13 Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg.kccicr@cwenscorning.com Authorized Signature Greg Keeler greq.keeler@cwenscorning.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory lJnderlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assura.nee Contract Expiration Date 12/31/2024 Validated By steven m_ uricn, Pt' Validation Checklist - Hardcopy Received Certificate of Independence ELL777 R13 01-R14002.10a 22 H Ev v other', k N n-HVHZ Tina€ pddf Referenced Standard and Year (of Standard) Standard Year ASTM D 1970 2015 ASTM D 226 2009 ASTM G 155 2013 https!//www.floridnbuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgtglccMGbIcW71%21Zr7gdugvKoCLUG7APd%2fOgNMaJnsl5ew%3d%3d Page 1 of 3 TAS 103 UL 1897 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/22/2020 Date Validated 10/23/2020 Date Pending FBC Approval 10/28/2020 Date Approved 12/15/2020 Date Revised 12/17/2020 Summary of Products 2020 2012 FL # Model, Number or Name Description 9777.1 Weatherlock G Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL9777 R13 II OCR14002.10a 2020 FBC Eval Weatherlock Non-HVHZ finilxdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports F1_9777 Rid AE OCR14902.1pa 2020 Fl3C Eve! Weatherlock Non-HVHZ finai,pdf Created by Independent Third Party: Yes 9777.2 Weatherlock G (High Tear) Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No 9777 R13 Il t]Ci214002.1Qa 20 0 FSC Eval 1--herlock Nan-HVHZ fnal.pd. Approved for use outside HVHZ: Yes Impact Resistant: H/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by Independent Third Party. Yes Other: See evaluation report for limits of use. Evaluation Reports FL9777 R13 AE OCR14QQ2,1Qd ZQaQ F F! Weatherlock Non-HVHZ final.124—f Created by Independent Third Party: Yes 9777.3 Weatherlock MAT Waterproofing Underlayment Limits of Use Installation instructions Approved for use in HVHZ: Yes FL 777 R13 II OCR14002.10b 2020 F8C_Eval W ht erloek Approved for use outside HVHZ: No HVHZ final.ndf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: NIA Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL9777 RI.3 AE OCR 14002.1Ob_242SLF�C Eval Weatherlvck V fin I. aff Created by IndependentThird Party: Yes 9777.4 1 Weatherlock MAT Waterproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL9777 R13.._II QCR14002A0a 2020 FSC_ Eval _Weath_erlDck Nan-HVH7 fln -d-f Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL9Z7Z_sU2._AE OCR14002.10a 2020 F13C Eval Weather Non-HVHZ fiPszl.oj http3.1/Www,flaridabuilding.orgjprjpr_app_dtl.aspx?param=wGi=VXQwtDgtgkcMGbloW7LJ2f2r7gdugvKoCLUG7APd`/2fCgNMaJnsIsew/3dl3d Page 2 of 3 Created by Independent Third Patty: Yes 9777.5 WeatherLock Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL9777�� II_�R14002.10a 2020 FBC Eval_Wga jtgrlprk Hon-HVHZ final.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Design pressure: N/A Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Other: See evaluation report For limits of use. Evaluation Reports FL9777 K13 A theripcic Noflfin�Lof Created by Independent Third Party: Yes 9777.6 WeatherLock Metal Weatherproofing Underlayment Limits of Use installation Instructions Approved for use in HVHZ: Yes FL9777 R13 II QGfL140U2.1flb 202Q FBC Eva1 WeatherLock HVHZ final.odf Approved for use outside HVHZ: No Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by Independent Third Party: Yes Other. See evaluation report for limits of use. Evaluation Reports FL9777 R13 AE OCR14002.10 2020 F13C_Eval_ W_Qath L1Q_i HVHZ final Created by Independent Third Party: Yes ' 9777.7 WeatherLock Specialty Tile &Metal Weatherproofing Underlayment Limits of Use installation Instructions Approved for use in HVHZ: No FL9777 R13 II OCRI4002,10a Z020 FBC_Eval We_athgL1E_cck Pion-HVHZ finaLof Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: +0/-142.5 Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL9777 R13 AEOCRI4002.10a 2020_F-K—nval_WQathe_rlxk Non-HVHZ finai.pdf Created by Independent Third Party: Yes Contact Us :: 2601 Glair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer, Capi 2007-2913 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone er by traditional mail. If you have any questions, please contact 850.487.1395. "Pursuant to Section 455.275(1), Florida statutes, effective October 1, 201,2, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The smalls provided may be used for official communication with the licensee. However email addresses are public record- If you do not wish to supply a personal address, please provide the Department with an emall address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please ruck here . P red u cF Approve l Accepts: Wd ® E'_ Credit Cares Safe https://www.floridabuilding.org/prfpr_app_dtl.aspx?param=wGEVXQwtDgtgkcMGbicW71%2fZr7gdugvKoCLUG7APd/2fogNMaJnsI5ew/3d%3d Page 3 of 3 CREEK 'K TECHNICAL SERVICES, LLC EVALUATION REPORT Manufacturer: Manufacturing Location: Quality Assurance SCOPE OWENS CORNING 1 Owens Corning Parkway Toledo, OH 43657 (800) 438-7465 www,owenscornin .corn Brentwood, NH Houston, TX Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL33547 (813) 480-3421 FLORIDA BUILDING CODE, 7"" EDITION (2020) PRi Construction Materials Technologies, LLC (QUA9110)) Issued October 23, 2020 Category: Roofing Subcategory: Underlayments Code Sections: 1504.3.1, 1507.1.1 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) NEI-039-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) NEI-042-02-01 RFV2 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) NEI-045-02-01 ASTM G 155 2013 PRI Construction Materials Technologies (TST5878) NEI-053-02-01 ASTM G 155 2013 PRI Construction Materials Technologies (TST5878) NEI-093-02-02 ASTM D 1970 2015a PRI Constructinn Materials Technologies (TST5878) DCF-213-02-01 ASTM D 1623 2009 PRI Construction Materials Technologies (TST5878) OCF-237-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST5878) 0CF-252-02-01 ASTM D 4798 2011 PRI Construction Materials Technologies (TST5878) DCF-252-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) OCF-253-02-02 ASTM D 1970 2015a PRI Construction Materials Technologies {TST5878} OCF-293-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) OCF-296-02-02 ICC-ES AC 188' 2012 lCC-FS AC 48 2012 PRI Construction Materials Technologies (TST5878) 0CF-297-02-01.1 ASTM D 1970 2015a PRI Construction Materials Technologies (TST5878) DCF-318-02-01 ASTM D 1910 2015a PRI Construction Materials Technologies (TST5878) OCF-320-02-01 ASTM G 155 2005a2013 PRI Construction Materials Technologies (TST5878) OOF-321-02-01 ASTM D 1623 2009 PRI Construction Materials Technologies (TST5878) OCF-322-02-01 UL 1B97 2012 PRI Construction Materials Technologies (TST5878) OCF-355-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST5878) 1378TO120 TAS 103 2020 PRI Construction Materials Technologies (TST5878) 1378TO121 ASTM U 1623 2019 TAS 103 2020 'Determined to be equivalent to ASTM D 226-09, Type I and II OCR14002.10a FL9777-R13 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61320-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid_ This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not cnorif,.-o El.r yAA--A h--i . CREEK TECHNICAL SERVICES, LL.0 PRODUCT DESCRIPTION AND LIMITS OF USE OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock® Underlayments (Nan-HVHZ) WeatherLock@ G WeatherLock® G is an ASTM D 1970 self -adhered underlayment constructed from SBS (Brentwood, NH or modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The Houston, DO product is supplied in 2-sq. rolls with nominal dimensions of 3-11. x 56.7-ft. WeatherLock@ G is permitted to be used as prescribed in FBC Section 1507.1.1 and Table 1507.1.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock® Mat WeatherLock@ Mat is an ASTM D 1970 self -adhered underlayment constructed from (Brentwood, NH or SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in Houston, r)O 1-sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq_ rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock@ Mat is permitted to be used as prescribed in FBC Section 1507.1.1 and Table 1507.1.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock@ Metal WeatherLock® Metal is an ASTM ❑ 1970 self -adhered underlayment constructed from (Brentwood, NH) SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The product is supplied in 2-0 sq- rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock® Metal is permitted to be used as prescribed in FBC Section 1507.1.1 and Table 1507.1.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 90 days. WeatherLock@ WeatherLockc® Specialty Tile & Metal is an ASTM ❑ 1970, TAS 103 and FRSAITRI Specialty Tile & Metal Florida High Wind Concrete and Clay Tile Installation Manula, Sixth Edition compliant (Brentwood, NH) self -adhered underlayment constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric. The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft. WeatherLock® Specialty Tile & Metal is permitted to be used as prescribed in FBC Section 1507.1 1 and Table 1507.1.1.1. WeatherLock@ Specialty Tile & Metal is permitted to be used with adhered clay or concrete We roofing using Dupont TILE BONDTM Roof Tile Adhesive. Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete the installations without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stack. WeatherLock® G WeatherLock® G (High Tear) is an ASTM D 1970 self -adhered underlayment used as an (High Tear) alternative to ASTM D 226, Type II roofing felt. The underlayment is composed of SBS (Houston, TX) modified asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The product is supplied with a nominal thickness of 50 mils In 1.95-sq rolls with nominal dimensions of 3-ft x 65-ft. WeatherLockg G (High Tear) is permitted to be used as prescribed in FBC section 1507.1.1 and Table 1507.1.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. OCR14002.10a FL9777-R13 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not c—-;rail, oAA.o -A herein CREEK TECI-INICAL SERVICES, LLC PRODUCT APPLICATION OWENS CORNING ROOFING ANU ASPHALT LLC Weathi Underlayments (.Non-li Min. Roof Slope: 2:12 in accordance with the FBC Application: All underiayments shall be installed in accordance with the FBC. Deck substrates shall he clean, dry, and free from any irregularifies and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment shall be installed with the release hacker removed and pressed firmly into place to ensure complete contact with the deck. The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with minimum 3" side laps and minimum 6" end laps staggered min. 6-ft.from preceding course. Additionally, if applying WeatherLockLa? Specialty Tile & Metal, end laps shall be primed with ASTM D 41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width of the lap. it is permissible to back nail the underlayment 12-inches on -center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). Additionally, Weathercock® Specialty Tile & Metal shall be back nailed when installed on roof slopes greater than 3:12. Min. Application 40`F; Contact the manufacturer when installing at temperatures below the minimum Temperature: application temperature. WIND RESISTANCE The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9 Underlayment System No.1 — Weathercock Specialty Tile & Metal Only Roof Deck: Min. 15l32-inch CDx plywood attached to wood supports spaced a maximum 24" O.C. underlayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with manufacturer's installation instructions to the fastened deck and backnalled along the selvage with minimum 12ga., 1-114-inch galvanized ring shank roofing nails through optionally primed, 32ga. x 1-5/8-inch 0 tin caps spaced 12" o.c_ The applied underlayment shall be railed with a minimum 751b steel roller immediately following application_ Maximum Design -142.5 psf Pressure: OCR14002.10a FL9777-R13 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not ii �u CREEK rrjTECHNICAL SERVICEs; LLC GENERAL LIMITATIONS OWENS CORNING ROOFING, AND ASPHALT LLC WeatherLoci@J Underlayments (Non-HVHZ) 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 6) All side lap seams small be installed to shed water from the deck. 7) The underiayment may be used as described in other current FBC product approval documents. 8) Design wind load pressures shall be determined for components and cladding in accordance with FSC 1609. 9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads determined for the roof assembly. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 7tr' Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer. �{�11i[if�j1 Edo 74021 Z y ir= STATE CF :•1� t O N A� S .t��� CERTIFICATION OF INDEPENDENCE 2020.10.23 /� 4�- 09:42:37 } ! woe�pi.n.eerLd�rRP.ik 04r00r Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEKTechnical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have. nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R_ Priest, P.E. does not have, nor will acquire, a financial interest in any other entity 6nvclved in the approval process of the product. END OF REPORT OCR14002.10a FI-9777-R13 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not