Loading...
HomeMy WebLinkAboutPA FL10758-R8Business Y i e f Replation RCM Home I Log In User Registration Hot Topics i SubmEt Surcharge Scats & Facts j Puhllcation5 Contact Us lM Sl Links Search O Product Approval USER: Public User Product Ao�rnyal Menu > Product or AlpplicaYinn Seardh a A=kati n�L�st> Appli—lien 11etali • FL # FLID758-RS f Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Ffprida License Quality Assurance Entity Quality Assurance Contract Expiration Bate Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 g reg_keeler0owenscorning.com Greg Keeler greg.keeler@owenscorning.com Greg Keeler 2790 Columbus Road Granville, OH 43023 {740)321-6345 greg.keelerCibowenscorning_com Roofing Roofing Accessories that are an Integral Part of the hoofing System Evaluation Report from a Florida Registered Architect Ora Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Zachary R. Priest PE-74021 PRI Construction Materlals Technologies, LLC 12/31/2024 Steven M. lirich, PE validation Checklist - Hardcopy Recefved FL10758 R8 C01 OCR]4003.4 2020 FBC Eva]] nVents f�inal_.p f hItps:Jiwww.floridabuilding.❑rg/pr/pr-app_dtl.2SPX?pararn=WGEVXQwtDgvTdAvlteOYC°/2bC3?F trydgGfPhgLACiVMFHfXgoD3ASJ4%3d%3d Page I of 3 Certified By Sections from the Code 1708.2 Product Approval Method Method 2 option a Date Submitted 09/10/2020 Date Validated 12/15/2020 Date Pending FBC Approval 09/18/2020 Date Approved 12/17/2020 FL # Model, Number ar Name 10758.1 VentSure 4-Foot Strip Hecit and Moisture Ridge Vents Limits of Use Approved for use In l lVH2: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other., Refer to evaluation report 10758.2 VentSure Low Profile Slant Back Roof Vent With Exterior LDUver Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Refer to evaluation report. 10758.3 I VentSure Rigid Roll Ridge Vent Description Copolymer plastic low profile attic ridge vents for installation in shingle roof systems Installation Instructions FL10758 R87I D R14003.4 2flZ FB Eval V nts final .pr1f Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL1 75 R8_AE R14 .4 ZQ20 FBC Eval Vents final df Created by Independent Third Party: Yes Galvanized metal roof vent Installation instructions FLIQ7._8$—R8_II OCRa4f1(1 ,4?n20 IBC..Eual Vents final .p_ f Verified By, Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports 8 O 14 Created by I ndepend e n t Th I rd Party: Yes Ridge Ventilation System Limits of Use Installation Instructions Approved for use in HVHZ: No F 07 _98 I�_ 9CR 4�903.4 202Q Mr, Eya1_ Von„ c final �df Approved for use outside HVHZ: Yes Verified By: Zachary R. Priest 74021 Impact Resistant: NIA Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Refer to evaluation report. EL1075 3—&$--AE -OCRI400,3.4 2020 en I .p-,f Created by Independent Third Party: Yes Back tti'exe Contact lls :: 2601 61air_stQnp Road_ Ta lahassee rr 32sao Ttie State of Florida is an AA/EE0 employer. Coo ' ht ZQD1 :7f11 3 crate r.r c�.,rpd - pn-lM--�tatement :: A P 16i �[dtpntEnt :: $gft{nd Statement Under Florida law, emali addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic maii to this entity. Instead, contact the office by phone or by traditional mail. If yea have any questions, please contact 050,437.1395. *Pursuant to Section 455.275(I), Florida statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. Ifyou do not w1sh to supply a personal address, please provide the Department with an email address which can be made available to the public.. To determine if you are a licensee under Chapter 455, F.S., please click here, Product Apprpvai Accepts! MWWFrtcl https:rywww.flcridabuilding.org/prjpr_app_dtl.aspx7param=wGEVXQwtDgvIdAvlte4Ypf2be3zFtrydg9fPhgLACIVmFHta'goD3ASJQl$dR,3d Page 2 of 3 ■ :5f'f'!17'3.C�`ht(°'1'ItIC off" https:llwww.tloridabuilding.org/prIPr_app_dtl.asPx?Par2m-wr,EVXQwtDgvldAvlteOYQ% 24C3zFtrydg9fPhgLACiVmFHfXgOD3ASJQ%3d%3d Page 3 of 3 CREEK Certificate of Autharizativn No. 298�4 ?. 17520 Edinburgh Dr x Tampa, FL 33647 TECHNICAL. SERVICES, LLC (813) 48d-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 7.. EDITION (2020) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued December 15, 2020 1 Owens Corning Parkway Toledo, OH 43657 (8DO)438-7465 www.owenscornin .corn Quality Assurance: PRI Construction Materials Technologies (C)UA9110) SCOPE Category: Roofing Subcategory: Roofing Accessories that are an Integral Part of the Roofing System Code Sections: 1708,2 Properties: Roof Venfilation REFERENCES Entity Architectural Testing, Inc (TST1558) Report No. 01-38660.04 Standard TAS 100(A) Year 1995 Architectural Testing, Inc (TST1558) 01-38660.05 TAS 100(A) 1995 Architectural Testing, Inc (TST1558) C1774.01-109-18 TAS 100(A) 1895 ASTM D 635 2014 ASTM D 1929 2016 PRI Construction Materials Technologies (TST5878) AVIG-005-02-01 ASTM D 2843 ASTM Dfi35 201 2014 ASTM D 1929 2016 PRI Construction Materials Technologies (TST5878) AVIG-006-02-01 ASTM D 2843 ASTM G 155 2016 2013 PRI Construction Materials Technologfes (TST5878) OCF-111-02-01 ASTM D 635 2014 ASTM D 1929 2016 PRI Construction Materials Technologies (TST5878) OCF-112-02-01 ASTM G 1553 2016 2013 PRI Construction Materials Technologies (TST5878) OCF-116-02-01 TAS 100(A) 1995 PRI Construction Materials Technologies (TST5878) OCF-223-02-01 TAS 100(A) 1995 PRl Construction Materials Technologies (T3T5878) ON1-007-02-01 TAS 100(A) 1995 OCR14003.4 FL10758-RS Pa e 1 of 5 This evacuation report is provided for State of Florida product approval under Rule 61G20 3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, ar other product attributes that a re not e x, ,n.. �a�ro��a� ho�a.. OWCORNING CREEK VentSure@ Roof Ventilation TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION AND APPLICATION VentSure"' 4-Foot Strip 1-114" x 14-718" x 48" iow-profile attic ridge vent consisting of a two -layer nylon - Heat and Moisture Ridge polyester composite. Available with or without a polyester fabric moisture barrier for Vents: installation in shingle roof systems. 1 1 14-718" Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope: Minimum 3:12 to maximum 16/12 Installation Height: Maximum 6e-ft Attachment Method: Cut a 2-inch opening (11-inch on each side of the ridge) centered in the deck at the ridge for ventilation. The slot shall terminate approximately 6-inches from the rake edges. Apply a '/4-inch wide bead of ASTM ❑ 4586 roofing cement along the entire length of the outside edges of the vent to seal the vent to the field shingles, taking care to not completely cover the weep slots in the vent. Center the vent over the opening and fasten to the deck using the 11 ga. 2'/2-inch galvanized ring shank nails (shall comply with FBC Section 1506.5) provided with the vent. Fasteners are to be installed on both sides of the vent 1, 12, 24, 36, and 47-inches from the start cf each vent piece. Prepare the adjacent vent section by applying the roofing cement along the edges, snap together with fixed vent, and fasten to the deck in the same manner as the first section_ Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line" with two (2) minimum 11 ga. 2%2-inch galvanized ring shank roofing nails (shall comply with FBC Section 1506.5) provided with the vent or as directed by the shingle manufacturer's installation instructions. Ailowable Roof Coverings: Asphalt shingles OCR14003.4 FL1 Q758-R8 Pa e 2 of 5 This evaluation repon is provided for State pf Florida product approval under Rule 61G2Q,3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration far which this report is valid. This evaluatlon report does not express nor imply warranty, installation, recommended use, or other product attributes that are not CREEK OWENS CORNING VentSurec� Roof Ventilation TECHNICAL SERVICES, I! i...0 VentSure Low Profile 18" x 24" x 2-3116" (32" x 23" flange base) static off -ridge vent composed of ASTM Slant Back Roof Vent A653 galvanized steel (available with painted finish). Material shall conform with with Exterior Louver: FBC Section 1507.4.3. Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBC requirements_ Roof slope: Minimum 3:12 Installation Height: Maximum 33-ft Attachment Method: Cut an 11 x 11-inch hole through wood sheathing only approximately 18-inches from the ridge. Apply 1M-inch thick by 3-inch wide bed of ASTM D 4586 roofing cement around inner and outer flange. Place vent directly over the hole, ensuring the vent sits flat on the roof. Fasten vent 4-inches o.c. and 1-inch from outside edge of flange with minimum 12 ga. ling shank roofing nails (shall comply with FBC Section 1506.5), ensuring %-inch penetration through wood deck (Minimum 18 nails per vent). Install baffle in Y.-inch bed of ASTM D 4586 roofing cement and secure with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5) spaced 8-inches o.c_ (total of (3) nails) while ensuring %-inch penetration through wood deck. Seal all nails and vent flange with ASTM D 4586 roofing cement. Allowable Roof Coverings: Asphalt shingles OCR 14003.4 FL10758-R8 page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Techri cal Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid, This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not anoniFn��l.. oANrs��o,-� {•,a.Q,n A_` CR1EEK 12N1 DWENS NG T�Ct-I�r1GAL S�Rvtc�s, LLCVentSureC Roof Ventilation VentSure(o Rigid Roil 518" x 11-114' x 20' attic ridge vent com osed of high density with a Ridge Vent: spun -bond polypropylene fabric. p g y ~RE L Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction- Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope: Minimum 2:12 to maximum 20:12 Installation Height: Maximum 60-ft Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the ridge for ventilation. The slot shall terminate approximately 12-inches from the rake edges. Apply a continuous bead of polyurethane adhesive sealant along the entire length of the outside edges of the vent to seal the vent to the field shingles. Center the vent over the opening and fasten the vent 24-inches o.c. to the deck using minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1505.5), ensuring Y inch penetration through wood deck. Fasten the ridge shingles over the vent to the deck on the marked -shingle nail line" with two (2) minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5) or as directed by The shingle manufacturer's installation instructions, ensuring %-inch penetration through wood deck. Outside edges of the shingles shall be sealed with flashing cement. Allowable Roof Coverings: Asphalt shingles LIMITATIONS 1) This report is not for use in the HVHZ. 2) Fire Classification is outside the scope of this evaluation. 3) The roof deck and deck attachment shall be designed by others in accordance with the FBC. 4) Owens Corning vents shall be installed in strict compliance with this evaluation report and the manufacturer's published installation instructions. In the event of conflict, the more restrictive installation shall be enforced_ 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the decK shall be checked for protrusion prior to installation. 6) Installation of the roof assembly is outside the scope of this evaluation. 7) Owens Corning vents are intended to provide passive ventilation for an enclosed attic in residential construction applications- 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. QCRt4003.4 FL1Q758 R8 Page 4 of 5 Techni This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK cal Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attrihutes that are not CREEK TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT OWENS CORNING VentSurep Roof Ventilation The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Ftodda Building Code, 7" Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer. t►►111 11rrrr►'�r IV NO 74021 �E Q: STATE OF :��► .�ff`Sy�fliAL�•�``• ►ill if11►►► CERTIFICATION OF INDEPENDENCE /j - 2020.12.15 13:59:34 -05'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest; P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR14003.4 FL14758-R8 This eval ation report is provided for State of Florida Product a Rage 5 of 5 p approval under Rufe 61G20-3. The manufacturer shall notify CREEK Technical Services; LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, instailation, recommended use, or other product attributes that are not c,.o..ifi 11-—4,f.os 4 ho.ai..