HomeMy WebLinkAboutPA FL10758-R8Business Y i e f Replation
RCM Home I Log In User Registration Hot Topics i SubmEt Surcharge Scats & Facts j Puhllcation5 Contact Us lM Sl Links Search
O
Product Approval
USER: Public User
Product Ao�rnyal Menu > Product or AlpplicaYinn Seardh a A=kati n�L�st> Appli—lien 11etali
• FL # FLID758-RS
f Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Ffprida License
Quality Assurance Entity
Quality Assurance Contract Expiration Bate
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
g reg_keeler0owenscorning.com
Greg Keeler
greg.keeler@owenscorning.com
Greg Keeler
2790 Columbus Road
Granville, OH 43023
{740)321-6345
greg.keelerCibowenscorning_com
Roofing
Roofing Accessories that are an Integral Part of the hoofing System
Evaluation Report from a Florida Registered Architect Ora Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Zachary R. Priest
PE-74021
PRI Construction Materlals Technologies, LLC
12/31/2024
Steven M. lirich, PE
validation Checklist - Hardcopy Recefved
FL10758 R8 C01 OCR]4003.4 2020 FBC Eva]] nVents f�inal_.p f
hItps:Jiwww.floridabuilding.❑rg/pr/pr-app_dtl.2SPX?pararn=WGEVXQwtDgvTdAvlteOYC°/2bC3?F trydgGfPhgLACiVMFHfXgoD3ASJ4%3d%3d Page I of 3
Certified By
Sections from the Code
1708.2
Product Approval Method Method 2 option a
Date Submitted
09/10/2020
Date Validated
12/15/2020
Date Pending FBC Approval
09/18/2020
Date Approved
12/17/2020
FL # Model, Number ar Name
10758.1 VentSure 4-Foot Strip Hecit and
Moisture Ridge Vents
Limits of Use
Approved for use In l lVH2: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other., Refer to evaluation report
10758.2 VentSure Low Profile Slant Back
Roof Vent With Exterior LDUver
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Refer to evaluation report.
10758.3 I VentSure Rigid Roll Ridge Vent
Description
Copolymer plastic low profile attic ridge vents for installation
in shingle roof systems
Installation Instructions
FL10758 R87I D R14003.4 2flZ FB Eval V nts final .pr1f
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL1 75 R8_AE R14 .4 ZQ20 FBC Eval Vents final df
Created by Independent Third Party: Yes
Galvanized metal roof vent
Installation instructions
FLIQ7._8$—R8_II OCRa4f1(1 ,4?n20 IBC..Eual Vents final .p_ f
Verified By, Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
8 O 14
Created by I ndepend e n t Th I rd Party: Yes
Ridge Ventilation System
Limits of Use Installation Instructions
Approved for use in HVHZ: No F 07 _98 I�_ 9CR 4�903.4 202Q Mr, Eya1_ Von„ c final �df
Approved for use outside HVHZ: Yes Verified By: Zachary R. Priest 74021
Impact Resistant: NIA Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Refer to evaluation report. EL1075 3—&$--AE -OCRI400,3.4 2020 en I .p-,f
Created by Independent Third Party: Yes
Back tti'exe
Contact lls :: 2601 61air_stQnp Road_ Ta lahassee rr 32sao
Ttie State of Florida is an AA/EE0 employer. Coo ' ht ZQD1 :7f11 3 crate r.r c�.,rpd
- pn-lM--�tatement :: A P 16i �[dtpntEnt :: $gft{nd Statement
Under Florida law, emali addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
maii to this entity. Instead, contact the office by phone or by traditional mail. If yea have any questions, please contact 050,437.1395. *Pursuant to Section
455.275(I), Florida statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. Ifyou do not w1sh to supply a
personal address, please provide the Department with an email address which can be made available to the public.. To determine if you are a licensee under Chapter
455, F.S., please click here,
Product Apprpvai Accepts!
MWWFrtcl
https:rywww.flcridabuilding.org/prjpr_app_dtl.aspx7param=wGEVXQwtDgvIdAvlte4Ypf2be3zFtrydg9fPhgLACIVmFHta'goD3ASJQl$dR,3d Page 2 of 3
■
:5f'f'!17'3.C�`ht(°'1'ItIC off"
https:llwww.tloridabuilding.org/prIPr_app_dtl.asPx?Par2m-wr,EVXQwtDgvldAvlteOYQ% 24C3zFtrydg9fPhgLACiVmFHfXgOD3ASJQ%3d%3d
Page 3 of 3
CREEK
Certificate of Autharizativn No. 298�4
?. 17520 Edinburgh Dr
x Tampa, FL 33647
TECHNICAL. SERVICES, LLC (813) 48d-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 7.. EDITION (2020)
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued December 15, 2020
1 Owens Corning Parkway
Toledo, OH 43657
(8DO)438-7465
www.owenscornin .corn
Quality Assurance: PRI Construction Materials Technologies (C)UA9110)
SCOPE
Category: Roofing
Subcategory: Roofing Accessories that are an Integral Part of the Roofing System
Code Sections: 1708,2
Properties: Roof Venfilation
REFERENCES
Entity
Architectural Testing, Inc (TST1558)
Report No.
01-38660.04
Standard
TAS 100(A)
Year
1995
Architectural Testing, Inc (TST1558)
01-38660.05
TAS 100(A)
1995
Architectural Testing, Inc (TST1558)
C1774.01-109-18
TAS 100(A)
1895
ASTM D 635
2014
ASTM D 1929
2016
PRI Construction Materials Technologies (TST5878)
AVIG-005-02-01
ASTM D 2843
ASTM Dfi35
201
2014
ASTM D 1929
2016
PRI Construction Materials Technologies (TST5878)
AVIG-006-02-01
ASTM D 2843
ASTM G 155
2016
2013
PRI Construction Materials Technologfes (TST5878)
OCF-111-02-01
ASTM D 635
2014
ASTM D 1929
2016
PRI Construction Materials Technologies (TST5878)
OCF-112-02-01
ASTM G 1553
2016
2013
PRI Construction Materials Technologies (TST5878)
OCF-116-02-01
TAS 100(A)
1995
PRI Construction Materials Technologies (TST5878)
OCF-223-02-01
TAS 100(A)
1995
PRl Construction Materials Technologies (T3T5878)
ON1-007-02-01
TAS 100(A)
1995
OCR14003.4 FL10758-RS Pa e 1 of 5
This evacuation report is provided for State of Florida product approval under Rule 61G20 3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, ar other product attributes that a re not
e x, ,n.. �a�ro��a� ho�a..
OWCORNING
CREEK
VentSure@ Roof
Ventilation
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION AND APPLICATION
VentSure"' 4-Foot Strip 1-114" x 14-718" x 48" iow-profile attic ridge vent consisting of a two -layer nylon -
Heat and Moisture Ridge polyester composite. Available with or without a polyester fabric moisture barrier for
Vents: installation in shingle roof systems.
1 1
14-718"
Deck Type:
Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shall be designed and installed in accordance with FBC
requirements.
Roof slope:
Minimum 3:12 to maximum 16/12
Installation Height:
Maximum 6e-ft
Attachment Method:
Cut a 2-inch opening (11-inch on each side of the ridge) centered in the deck at the
ridge for ventilation. The slot shall terminate approximately 6-inches from the rake
edges. Apply a '/4-inch wide bead of ASTM ❑ 4586 roofing cement along the entire
length of the outside edges of the vent to seal the vent to the field shingles, taking
care to not completely cover the weep slots in the vent. Center the vent over the
opening and fasten to the deck using the 11 ga. 2'/2-inch galvanized ring shank nails
(shall comply with FBC Section 1506.5) provided with the vent. Fasteners are to be
installed on both sides of the vent 1, 12, 24, 36, and 47-inches from the start cf each
vent piece.
Prepare the adjacent vent section by applying the roofing cement along the edges,
snap together with fixed vent, and fasten to the deck in the same manner as the first
section_ Fasten the ridge shingles over the vent to the deck on the marked "shingle
nail line" with two (2) minimum 11 ga. 2%2-inch galvanized ring shank roofing nails
(shall comply with FBC Section 1506.5) provided with the vent or as directed by the
shingle manufacturer's installation instructions.
Ailowable Roof Coverings:
Asphalt shingles
OCR14003.4 FL1 Q758-R8 Pa e 2 of 5
This evaluation repon is provided for State pf Florida product approval under Rule 61G2Q,3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration far which this report is valid.
This evaluatlon report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
CREEK OWENS CORNING
VentSurec� Roof Ventilation
TECHNICAL SERVICES, I! i...0
VentSure Low Profile 18" x 24" x 2-3116" (32" x 23" flange base) static off -ridge vent composed of ASTM
Slant Back Roof Vent A653 galvanized steel (available with painted finish). Material shall conform with
with Exterior Louver: FBC Section 1507.4.3.
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shall be designed and installed in accordance with FBC
requirements_
Roof slope: Minimum 3:12
Installation Height: Maximum 33-ft
Attachment Method: Cut an 11 x 11-inch hole through wood sheathing only approximately 18-inches from
the ridge. Apply 1M-inch thick by 3-inch wide bed of ASTM D 4586 roofing cement
around inner and outer flange. Place vent directly over the hole, ensuring the vent
sits flat on the roof. Fasten vent 4-inches o.c. and 1-inch from outside edge of flange
with minimum 12 ga. ling shank roofing nails (shall comply with FBC Section
1506.5), ensuring %-inch penetration through wood deck (Minimum 18 nails per
vent).
Install baffle in Y.-inch bed of ASTM D 4586 roofing cement and secure with
minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5)
spaced 8-inches o.c_ (total of (3) nails) while ensuring %-inch penetration through
wood deck. Seal all nails and vent flange with ASTM D 4586 roofing cement.
Allowable Roof Coverings: Asphalt shingles
OCR 14003.4 FL10758-R8 page 3 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Techri cal Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid,
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
anoniFn��l.. oANrs��o,-� {•,a.Q,n
A_`
CR1EEK 12N1
DWENS NG
T�Ct-I�r1GAL S�Rvtc�s, LLCVentSureC Roof Ventilation
VentSure(o Rigid Roil 518" x 11-114' x 20' attic ridge vent com osed of high density with a
Ridge Vent: spun -bond polypropylene fabric. p g y
~RE
L
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction- Roof deck shall be designed and installed in accordance with FBC
requirements.
Roof slope: Minimum 2:12 to maximum 20:12
Installation Height: Maximum 60-ft
Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the
ridge for ventilation. The slot shall terminate approximately 12-inches from the rake
edges. Apply a continuous bead of polyurethane adhesive sealant along the entire
length of the outside edges of the vent to seal the vent to the field shingles. Center
the vent over the opening and fasten the vent 24-inches o.c. to the deck using
minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1505.5),
ensuring Y inch penetration through wood deck.
Fasten the ridge shingles over the vent to the deck on the marked -shingle nail line"
with two (2) minimum 12 ga. ring shank roofing nails (shall comply with FBC Section
1506.5) or as directed by The shingle manufacturer's installation instructions,
ensuring %-inch penetration through wood deck. Outside edges of the shingles shall
be sealed with flashing cement.
Allowable Roof Coverings: Asphalt shingles
LIMITATIONS
1) This report is not for use in the HVHZ.
2) Fire Classification is outside the scope of this evaluation.
3) The roof deck and deck attachment shall be designed by others in accordance with the FBC.
4) Owens Corning vents shall be installed in strict compliance with this evaluation report and the
manufacturer's published installation instructions. In the event of conflict, the more restrictive installation
shall be enforced_
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the decK
shall be checked for protrusion prior to installation.
6) Installation of the roof assembly is outside the scope of this evaluation.
7) Owens Corning vents are intended to provide passive ventilation for an enclosed attic in residential
construction applications-
8) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
QCRt4003.4 FL1Q758 R8 Page 4 of 5
Techni
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
cal Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attrihutes that are not
CREEK
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
OWENS CORNING
VentSurep Roof Ventilation
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Ftodda Building
Code, 7" Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer.
t►►111 11rrrr►'�r
IV
NO 74021
�E
Q: STATE OF :��►
.�ff`Sy�fliAL�•�``•
►ill if11►►►
CERTIFICATION OF INDEPENDENCE
/j -
2020.12.15
13:59:34
-05'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest; P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
OCR14003.4 FL14758-R8
This eval ation report is provided for State of Florida Product a Rage 5 of 5
p approval under Rufe 61G20-3. The manufacturer shall notify CREEK
Technical Services; LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, instailation, recommended use, or other product attributes that are not
c,.o..ifi 11-—4,f.os 4 ho.ai..