HomeMy WebLinkAboutEngineering 7-16 - PEAK ROOF HEIGHT LESS THAN OR EQUAL TO 60 FEET ak HOLESALE) GREATER OR EQUAL THAN 12'-3" OSITIVE NEGATIVE TE A.S.D. ULTIMATE I A.S.D. * INDICATED DESIGN WIND PRESSURES 41.1 86.4 51.8 CORRESPOND TO THE MAXIMUM END 43.2 ZONE AND INTERIOR ZONE CONDITIONS 90.8 54.5 AND FOR ALL ROOF 44.9 94.4 56.6 SLOPES. 46.4 97.4 = STORM PANEL LENGTH, 58.4 ** L ACCORDION SHUTTER 48.7 102.4 61.4 BLADE ELENGTH HOR BAHAMA 50.6 106.5 63.9 52.3 109.9 65.9 *** MIAM T. PRODUCTS COUNTY OR A STATE OF FLORIDA APPROVAL FEET* LESALE) pIoo (F,1 FGATIVE E I A.S.D. 1 89.0 91 1 BUILDING SCHEMATIC 93.0 94.7 97.8 1ilNlllillllli►ls,, 100.4 02.8 104.9 ' 106.9 * No. 44167 114.7 rn STATE .*= z-o'• OF ;w 117.8 �• ,.����: 120.5 125.3 2020 (7th EDITION) FLORIDA BUILDING CODE - BR06YARD, PALM BEACH, MARTIN, ST LUCIE & INDMN RIVER COUNTIES 02020 TILTECO, INC ASCE 7-16 / WIND PRESSURE CHART M.P STORM PANELS, ACCORDION & BAHAMA SHUTTERS *** DRAWN BY RISK CAT. If BLDGS 0612312020 /'7rlL I E C O I N C. DATE nUff TESTING & ENGINEERING COMPANY WIND PRESSURE CHART 6355 N.W.36th.St. Ste. 305, WRQNIA G4ROEN' R.33166 BASIC WIND SPEED = 170 mph RED BY Phone:(305f67l-1530.Fox:(305)671-1531 EXPOSURE Q Kd = 0.85 20•-1 17 CA-0006719 DRAWING No WALTER A. 77LLff Jr. P.E. Rcr.N. 0MW are M.ft 0�cxlmav arc FLORIDA Lic. 7f 44167 1 OLD 17-794 106123120MI a 1 SHEET 1 OF 1 i BUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS & CLADDING Z F) FOR ASCE BASIC WIND SPEED = 170 mph RISK CATEGORY l/ BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, PEAK L- LESS THAN 7'-9" L'• GREATER OR EQUAL THAN 7'-9"AND L, ROOF LESS THAN 12'-3" HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULT/h 0' - 15' 76.4 45.8 102.4 61.4 73.0 43.8 95.5 57.3 68. > 15'-20' 80.4 48.2 107.6 64.6 76.8 46.1 100.4 60.2 72. > 20'-25' 83.6 50.2 111.9 67.1 79.8 47.9 104.4 62.6 74. > 25'-30' 86.2 51.7 115.5 69.3 82.4 49.4 107.7 64.6 77. > 30'-40' 90.7 54.4 121.4 72.8 86.6 52.0 113.3 68.0 81.. > 40'-50' 94.3 56.6 126.2 75.7 90.0 54.0 117.7 70.6 84. > 50'-60' 97.3 58.4 130.3 78.2 92.9 55.7 121.5 72.9 87.. BWLDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS & CLADDING MS F.) FOR BASIC WIND SPEED = 170 mph RISK CATEGORY II BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHl PEAK L+= LESS THAN 12-3" L"' GREATER OR EQUAL THA ROOF HEIGHT POSITIVE NEGATIVE POSITIVE A (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMA > 6o' - 7o' 91.5 54.9 167.7 100.6 84.3 50.6 148. > 70' - 80' 93.6 56.2 171.6 103.0 86.2 51.7 151. > 80' - 90' 95.6 57.4 1 175.2 105.1 88.0 52.8 155. > 9o, - l oo' 97.3 58.4 1 178.4 107.4 89.7 53.8 157. > 100' - 120' 100.5 60.3 184.2 110.5 92.5 55.5 163. > 120' - 140' 103.2 61.9 189.2 113.5 95.1 57.1 167. > 140' - 160' 105.6 63.4 193.6 716.2 97.3 58.4 171.. > 160' - 180' 107.8 64.7 197.6 718.6 99.3 59.6 174.t > 180' - 200' 109.8 65.9 201.3 120.8 101.1 60.7 178. > 200' - 250' 114.1 68.5 209.2L129.6 105.2 63.1 185. > 250' - 300' 117.8 70.1 216.0 108.5 65.1 191. > 300' - 350' 121.0 72.6 221.9 111.5 66.9 196., > 350' - 400' 123.9 74.3 227.1 114.1 68.5 200.F > 400' - 450' 126.4 75.8 231.8 116.5 69.9 205.. > 450' - 500' 128.8 77.3 236.1 118.6 1 71.2 1 208.c .EL4� 1.) THIS CERTIFIED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY THIS ENGINEER, BASED ON ASCE 7-16, FOR A BASIC WIND SPEED OF 170 MPH, AND APPLICABLE RISK CATEGORY BUILDING do EXPOSURES, IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT. 2.) THIS WIND LOAD CHART MUST BE SIGNED, SEALED AND DATED BY THIS ENGINEER IF USED TO OBTAIN A ONE TIME BUILDING PERMIT. 3.) CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELECTION OF DESIGN WIND PRESSURE BASED ON THIS GENERIC WIND LOAD CHART WIND PRESSURES ARE ULTIMATE AND A.S.D. PRESSURES. 4.) THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS. 5.) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPo THE CONTRACTOR OR PERMIT HOLDER (e.g., SPREADSHEET, OPENING SCHEDULE/TAKE OFF SHEET, ETC.).