Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED Gamez NOC
NEMO I etc. Certificate of Authorization#32455 353 Christian Street, Unit#13 Oxford,CT 06478 0 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION • CertainTeed, LLC Evaluation Report 3532.09.05-1117 20 Moores Road FL5444-1116 Malvern, PA 19355 Date of Issuance:09/22/2005 (610)893-5400 Revision 17:07/24/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7" Edition(2020) Florida Building Code sections noted herein. DESCRIPTION: CertainTeed Asphalt Roof Shingles. LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 14. Prepared by: \,;,r,.,, __ 0. Robert J.M. Nieminen,P.E. - = 4F,. Florida Registration No.59166,Florida DCA ANE1983 + ct .,`¢ rr -' The facsimile seal appearing was authorized by Robert Nieminen,P.E.on 07/24/2020. This does not serve as an ',Faber:eae0i t" electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018 NEMO ETC,LLC ONEMOletc. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: CertainTeed Asphalt Roof Shingles, as produced by CertainTeed, LLC, have demonstrated compliance with the following sections of the 7'Edition(2020)Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Material standard ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind resistance ASTM D7158 2019 3. REFERENCES: Entity Examination Reference Date PRI(TST 5878) ASTM D3161 256T0015 08/12/2019 UL(TST 1740) ASTM D3161 99NK26506 11/23/1999 UL(TST 1740) ASTM D3161 03CA12702 05/27/2003 UL(TST 1740) ASTM D3161 03CA12702 06/16/2003 UL(TST 1740) ASTM D3161 03NK29847 10/03/2003 UL(TST 1740) ASTM D3161 04CA11329 05/24/2004 UL(TST 1740) ASTM D3161 04CA32986 12/03/2004 UL(TST 1740) ASTM D3161 05NK07049 04/15/2005 UL(TST 1740) ASTM D3161 05NK16778 05/12/2005 UL(TST 1740) ASTM D3161 05CA16778 05/12/2005 UL(TST 1740) ASTM D3161 05NK14836 05/22/2005 UL(TST 1740) ASTM D3161 05NK22800 06/22/2005 UL(TST 1740) ASTM D3462 R684 09/21/2005 UL(TST 1740) ASTM D7158 05NK08037 06/28/2006 UL(TST 1740) ASTM D3161&D3462 09CA28873 07/23/2009 UL(TST 1740) ASTM D3462 10CA41303 10/07/2010 UL(TST 1740) ASTM D3161 10CA41303 10/08/2010 UL(TST 1740) ASTM D7158 10CA41303 10/27/2010 UL(TST 1740) ASTM D3161&D3462 10CA44960 11/11/2010 UL LLC(TST 9628) ASTM D3161,D3462&D7158 13CA32897 11/21/2013 UL LLC(TST 9628) ASTM D3161,D3462 TFWZ.R684 04/22/2014 UL LLC(TST 9628) ASTM D7158 TGAH.R684 04/22/2014 UL LLC(TST 9628) ASTM D3161&D3462 4786334434 09/16/2014 UL LLC(TST 9628) ASTM D3161&D3462 4786570826 02/12/2015 UL LLC(TST 9628) ASTM D3161 4786821352 02/21/2015 UL LLC(TST 9628) ASTM D3161,D3462&D7158 4786570717 12/16/2015 UL LLC(TST 9628) ASTM D3161&D3462 4787195678 02/09/2016 UL LLC(TST 9628) ASTM D3161,D3462&D7158 4787592174 10/21/2016 UL LLC(TST 9628) ASTM D3161,D3462&D7158 4787380356 10/26/2016 UL LLC(TST 9628) ASTM D3462 4787380357 10/13/2016 UL LLC(TST 9628) ASTM D7158 4787380357 11/08/2016 UL LLC(TST 9628) ASTM D3161 4787380357 11/09/2016 UL LLC(TST 9628) ASTM D3161,D3462&D7158 4787586427 01/25/2017 UL LLC(TST 9628) ASTM D3161&D3462 4788042412 11/15/2017 UL LLC(TST 9628) ASTM D3161,D3462&D7158 4788362767 03/03/2018 UL LLC(QUA 9625) Quality Control Service Confirmation 11/13/2019 NEMO ETC,LLC Evaluation Report 3532.09.05-1117 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-R16 CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020 Page 2 of 14 NNEMO etc. TABLE 1:ASPHALT SHINGLE COMPONENTS Type Product Description Material Plant(s) Standard Fiberglass reinforced starter shingle, High-Performance Starter measuring 10"x 36",for use with ASTM D3462 NC Grand Manor®and Highland Slate® Fiberglass reinforced starter shingle, measuring 13-1/4"x 40",with a Presidential°Starter reinforcement on the underside,for ASTM D3462 CA(F) use with Presidential Shake®and Starter Presidential Shake®TL Strips Fiberglass reinforced starter shingle, Presidential®Starter IR measuring 13-1/4"x 40",for use with ASTM D3462 CA(F) Presidential Shake®IR Fiberglass reinforced starter strip, SwiftStart®Starter Shingle measuring 15-1/4"x 38-3/4" ASTM D3462 MN Fiberglass reinforced starter shingle, measuring 7"x 36",for use with Universal Starter shingles measuring 12"x 36"having a ASTM D3462 NC weather exposure<5" CT 201m LA,NC CT 20T" Metric OR XTT 25 Fiberglass reinforced,3-tab asphalt ASTM D3462 LA,MN,NC,OH roof shingle XTT 25 Metric OH,OR XTTm 30 1 R LA Highland Slate® Fiberglass reinforced,4-tab asphalt ASTM D3462 NC roof shingle Arcadialm CA(F) Belmont® NC Belmont®IR NC Carriage House® NC Grand Manor® NC Landmark® CA(W),GA,LA,MA,MO, MN,NC,OH,OR,TX Landmark®Pro Fiberglass reinforced,laminated ASTM D3462 CA(W),GA,MA,MO,MN, Asphalt asphalt roof shingle OH,NC Shingles Landmark®Pro Architect 80 OR Landmark Pro Solaris® CA(W) Landmark®Premium CA(W),MA,MN,OR,NC Landmark Solaris® CA(W),OR Landmark Solaris®Gold/Platinum OR Landmark®TL CA(F) Landmark®TL Solaris CA(F) Fiberglass reinforced,laminated,SBS NorthGate® Fiber g ASTM D3462 MN,OR modified bitumen roof shingle Presidential Shake® CA(F),MN Presidential Shake®IR MN Presidential Shake®TL Fiberglass reinforced,architectural ASTM D3462 CA(F),MN Presidential Solaris® asphalt roof shingle CA(F) Presidential TL Solaris CA(F) Fiberglass reinforced asphalt roof Patriot ASTM D3462 OH,OR strip-shingle; laminated appearance Note: Any of the above listed shingles may be produced in AR(algae resistant)versions NEMO ETC,LLC Evaluation Report 3532.09.05-R17 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-R16 CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020 Page 3 of 14 ONEMOletc. TABLE 1(CONTINUED):ASPHALT SHINGLE COMPONENTS Type Product Description Material Plant(s) Standard Shangle Ridge° ASTM D3462 NC Shadow Ridge® ASTM D3462 MA,MN,NC,OH Hip& Shadow Ridge®Metric ASTM D3462 OR Ridge Cedar Crest® Fiberglass reinforced accessory None NC Shingles Cedar Crest®IR shingles for hip and ridge installation None NC NorthGate®Ridge ASTM D3462 OR NorthGate°Accessory ASTM D3462 MN S. LIMITATIONS: 5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications. TABLE 2A:WIND CLASSIFICATIONS,ASPHALT SHINGLES Product FBC Table 1507.2.7.1 or R905.2.6.1 CT 20'" ASTM D3161(F)&ASTM D7158(H) CT 20T"Metric ASTM D3161(F)&ASTM D7158(H) XTT"25 ASTM D3161(F)&ASTM D7158(H) XT'"25 Metric ASTM D3161(F)&ASTM D7158(H) XT'"30 IR ASTM D3161(F)&ASTM D7158(H) Arcadia'" ASTM D3161(F)&ASTM D7158(H) Belmont° ASTM D3161(F)&ASTM D7158(H) Belmont('IR ASTM D3161(F)&ASTM D7158(H) Carriage House' ASTM D3161(F)&ASTM D7158(H) Grand Manor' ASTM D3161(F)&ASTM D7158(H) Landmark® ASTM D3161(F)&ASTM D7158(H) Landmark®Pro ASTM D3161(F)&ASTM D7158(H) Landmark®Pro Architect 80 ASTM D3161(F)&ASTM D7158(H) Landmark Pro Solaris® ASTM D3161(F)&ASTM D7158(H) Landmark'Premium ASTM D3161(F)&ASTM D7158(H) Landmark Solaris® ASTM D3161(F)&ASTM D7158(H) Landmark Solaris®Gold/Platinum ASTM D3161(F)&ASTM D7158(H) Landmark®TL ASTM D3161(F)&ASTM D7158(H) NorthGate® ASTM D3161(F)&ASTM D7158(H) Presidential Shake® ASTM D3161(F)&ASTM D7158(H) Presidential Shake°IR ASTM D3161(F)&ASTM D7158(H) NEMO ETC,LLC Evaluation Report 3532.09.05-1117 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-R16 CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020 Page 4 of 14 ONEMOletc. TABLE 2A:WIND CLASSIFICATIONS,ASPHALT SHINGLES Product FBC Table 1507.2.7.1 or R905.2.6.1 Presidential Shake®TL ASTM D3161(F)&ASTM D7158(H) Presidential Solaris° ASTM D3161(F)&ASTM D7158(H) Presidential TL Solaris ASTM D3161(F)&ASTM D7158(H) Highland Slate" ASTM D3161(F)&ASTM D7158(H) Patriot ASTM D3161(F)&ASTM D7158(H) 5.5.1 Classification by ASTM D7158: ASTM D7158,Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. Analysis in accordance with ASTM D7158 indicates the measured uplift resistance(RT or RA)for the CertainTeed asphalt Roof shingles listed in Table 1(except Presidential Solaris° Landmark Pro Solaris°and Landmark Solaris° Gold/Platinum)exceeds the calculated uplift force(FT) under the following conditions: • maximum design wind speed of Vasd=150 mph (V,it=194 mph) • located in Exposure D conditions • no topographical variations(flat terrain) • having a mean roof height less than or equal to 60 feet. The shingles (except Presidential Solaris° Landmark Pro Solaris® and Landmark Solaris° Gold/Platinum) are permissible under Code for installation in these conditions using the installation procedures detailed in this Evaluation Report and CertainTeed minimum requirements,subject to minimum codified fastening requirements established within any local jurisdiction,which shall take precedence. TABLE 213:WIND CLASSIFICATIONS,STARTER STRIPS AND HIP&RIDGE Type Product FBC Table 1507.2.7.1 or R905.2.6.1 High-Performance Starter ASTM D3161,Class F Presidential®Starter ASTM D3161,Class F Starter Strips Presidential°Starter IR ASTM D3161,Class F SwiftStart®Starter Shingle ASTM D3161,Class F Universal Starter ASTM D3161,Class F Shangle Ridge® ASTM D3161,Class F(sealant required,See Section 6) Shadow Ridge°(NC production) ASTM D3161,Class F Shadow Ridge°(MA,MN or OH production) ASTM D3161,Class F(sealant required,See Section 6) Hip&Ridge Shadow Ridge®Metric(OR production) ASTM D3161,Class F(sealant required,See Section 6) Shingles Cedar Crest° ASTM D3161,Class F(sealant required,See Section 6) Cedar Crest'IR ASTM D3161,Class F(sealant required,See Section 6) NorthGate®Ridge ASTM D3161,Class F NorthGate®Accessory ASTM D3161,Class F 5.5.2 High-Performance Starter shingles are limited to use with Grand Manor®and Highland Slate®shingles. 5.5.3 Presidential' Starter shingles must be applied using two (2) overlapping layers and are limited to use with Presidential Shake'and Presidential Shake®TL shingles. 5.5.4 Presidential' Starter IR shingles must be applied using two (2) overlapping layers and are limited to use with Presidential Shake®IR shingles. 5.5.5 Universal Starter shingles are limited to use with CertainTeed shingles measuring 12" x 36" having a weather exposure<5". NEMO ETC,LLC Evaluation Report 3532.09.05-R17 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-R16 CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020 Page 5 of 14 ONEMOletc. 5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. 6. INSTALLATION: 6.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.1 Underlayment shall be acceptable to CertainTeed,LLC and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Installation of asphalt shingles shall comply with the CertainTeed, LLC current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or Section R905.2.6 and the minimum requirements herein. 6.2.1 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.2 Where the roof slope exceeds 21 units vertical in 12 units horizontal, use the"Steep Slope"directions. 6.3 CertainTeed asphalt shingles are acceptable for use in reroof (tear-off) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and CertainTeed published installation instructions. 6.4 HIGH-PERFORMANCE STARTER: 6.4.1 Eaves: For the first starter shingle in each roof corner, use five(5) nails as shown below. All other starter shingles require four(4) nails per shingle. Nails must be of sufficient length to penetrate into the deck 3/4" or through the thickness of the decking,whichever is less. Nails are to be 11 or 12 gauge, corrosion-resistant roofing nails with 3/8" heads. Apply the 10"starter shingle with its factory-applied sealant stripes at the shingle's lower-most edge and nail firmly into the roof deck as near as possible*(maximum 3")to the eaves edge while avoiding the sealant.With the starter shingle well fastened to the deck and the sealant low on the starter shingle,it can firmly adhere to the first course shingles. *If nailing within 3"is not possible, nail as closely as possible,then lift and adhere the starter shingle to the underlayment and to the supporting structure with CertainTeed FlintBond'"Asphalt Roofing Cement-Caulk Grade,or approved equal. Rakes: Prior to installation of the field shingles,starter shingles may be applied up the slope along the rake edge with sealant edge placed closest to the rake edge. Fasten as indicated below. HIGH-PERFORMANCE STARTER SHINGLES 36" �1 318 (Max 3•) NEMO ETC,LLC Evaluation Report 3532.09.05-1117 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-R16 CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020 Page 6 of 14 ONEIVIOletc. 6.5 PRESIDENTIAL®STARTER AND PRESIDENTIAL®STARTER IR: 6.5.1 General: These shingles shall be applied by using two(2)overlapping layers. Begin application of the bottom/lower layer of starter shingles by cutting and applying a 13-3/4"x 20" piece at the lower left rake/eaves corner overhanging rakes and eaves 1/4"to 3/4". Continue along the eaves with full-size 13-1/4"x 40"starter shingles. Each top/upper starter course shingle shall have its 2"top section removed at the perforations, resulting in 11-1/4"x 40"shingles.The colored granule portion of the"top"starter shingles shall be located nearest the lowermost eave edge. Install the first top/upper starter shingle so that it is flush to the left side and bottom edges of the first bottom/lower starter shingle. This first top/upper starter shingle shall be 11-1/4"x 38". Continue along the eaves with 11-1/4"x 40"top/upper starter shingles ensuring that the lower edges are flush with the lower edges of the bottom/lower layer. Reference the product's wrapper for more specific details. Eaves: Fasten as shown below. Rakes:After applying the starter shingles at the eaves, but prior to installing the field shingles,starter shingles may be applied up the slope at the rake edge. Fasten as shown below. Fastening: Four nails are required per shingle. Nails shall be of sufficient length to penetrate into the deck 3/4" or through the thickness of the decking,whichever is less. Nails are to be 11 or 12 gauge,corrosion-resistant roofing nails with 3/8" heads. Presidential Starter and Presidential IR Starter Shingles -�2a a 1st Bodom Starter Full Bottorn Starter 134, 1st T38SYnrtar td E 4- 6.6 UNIVERSAL STARTER: 6.6.1 General: While Universal Starter Strip shingles are specifically designed to be used with shingles 36" length and having a weather exposure of<5",they may be installed beneath shingles of any length if special precautions are taken. IMPORTANT: In all cases the end joints of the starter and the first course shingles shall NEVER BE LESS THAN 3-1/2"apart. Eaves: The sealant on starter courses should face out and lie as close as possible to the eaves edge of the roof. Fasten as described below. Rakes: After applying the starter shingles at the eaves, but prior to installing the field shingles,starter shingles may be applied up the slope at the rake edge with sealant facing out and nearest to the outer roof edge. Fasten as described below. Fastening: Use four nails on these starter shingles as shown below. The sealant on starter courses shall lie as close as possible to the eaves edge of the roof. Nails shall be of sufficient length to penetrate into the deck 3/4" or through the thickness of the decking,whichever is less. Nails are to be 11 or 12 gauge,corrosion-resistant roofing nails with 3/8" heads. UNIVERSAL STARTER SHINGLES 36' 12" 12' 12" 7- Max. 3'���������i�������� NEMO ETC,LLC Evaluation Report 3532.09.05-R17 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-1116 CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020 Page 7 of 14 NNEMO etc. 6.7 SWIFTSTART®STARTER SHINGLE: Fastening: Use four nails, located as shown below 38-3/4"(984 mm) }I 1"(25 mm)from edge 1'(25 mm)from edge I 7-5A (194 mm) Max 3' a s (76 mm) _ tThe inner two fasteners must be placed such that they fall at least 3'(76 mm)from the end joints of the shingle in the succeeding course. 6.8 CT 20'-,XT'-25,X17-30 Ill LOW AND STANDARD SLOPE STEEP SLOPE ENGLISH 12'' 12" 12'' Use four nails and six spots of asphalt roofing cement*for every full (305 mm) (305 mm) (305 mm)--� shingle(Figure 11-4).Asphalt roofing cement meeting ASTM D4586 1"(25 mm) Sealant 1"(25 mm) Type II is suggested. 5 GIs"(145 mm) 5��2„for Norwoo d Planf � -- - - --- - - --- 131/8'' 131/8" 121/8" Roof METRIC ing Cement 1"(25 mm) Sealant 1"(25 mm) Apply 1"(25 mm)spots of asphalt roofing cement It under each tab corner. 61/a Figure11-4:Usefournailsandsix spots ofasphaltcernenton steep slopes. *CAUTION:Excessive use of roofing cement can cause shingles to blister. Figure 11-3:Use four nails for every full shingle. Hip&Ridge: Cut Shingles Note: The use of BASF'Sonolastic°NP1T""adhesive or Henkel"PLI Polyurethane Roof&Flashing Sealant"in accordance with CertainTeed requirements is required for the ASTM D3161, Class F wind rating. 1"—� �t �� 2''(50 mm) Remove 5„ 1211(305 mm)�� �goh (25mm) �I —�_Remove_' (125mm7 f F ' 412'' ~(CapCap 305mm] �Shi gle t2 ko�No Figure 11-24:Cut tabs,then trim back to make cap shingles (English dimensions shown), Figure I1-25.'Installation of caps along the hips and ridges. NEMO ETC,LLC Evaluation Report 3532.09.05-R37 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-R16 CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020 Page 8 of 14 ONEMOjetc. 6.9 ARCADIATM: LOW AND STANDARD SLOPE STEEP SLOPE Use SIX mails for every full shingle located as shown below. Use SIX nails and FOUR spots of asphalt roofing cement for every full shingle as shown below.Apply asphalt roofing cement 1"(25 mm) from edge of shingle.Asphalt roofing cement meeting ASTM D 4586 Type II is suggested. f P'(zs mm) 1'(zs mm)y t Nail Line Nail Nail Line 1"(25 mm) 1"(25 mm) f Figure 2:Use six nails for every full shingle. ,, 0 ,, Figure 3:Use six nails and four spots of asphalt roofing cement on steep slopes. Hip&Ridge: Cedar Cl or Cedar Crest® IR Use two (2), minimum 134-inch long fasteners per shingle. For the starter shingle, place fastener 1-inch from each side edge and about 2-inch up from the starter shingle's exposed butt edge, ensuring minimum %-inch embedment into the deck,or full penetration through the deck. For each full Cedar Crest shingle,place fasteners 8-5/8-inch up from its exposed butt edge and 1-inch from each side edge. Note: The use of BASF"Sonolastic°NP1"'adhesive or Henkel"PLO Polyurethane Roof&Flashing Sealant"in accordance with CertainTeed requirements is required for the ASTM D3161, Class F wind rating. Hand-sealing adhesive 12" 411 0 �mm) (305 mrn) 114" - 314" Dab of asphalt cement between 1 shingle layers NEMO ETC,LLC Evaluation Report 3532.09.05-11117 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-1 EVALUATION FL5444-R16 CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020 Page 9 of 14 NNEMO etc. 6.10 BELMONT®OR BELMONT®IR: Low and Standard Slope Steep Slope (greater than 21:12): (2:12 to 21:12): Use SEVEN nails and EIGHT spots of Use FIVE nails for every full Belmont shingle, asphalt roofing cement"for every full located as shown below_ Belmont shingle.Apply asphalt roofing 4 cement 1"(25mm)from edge of shingle_ "ai�mml { See below.Asphalt roofing cement meeting i— �—1'(25 mrn] 1'f7.5 mrn] ASTM a4586 Type II is suggested_ 5+8'I16 nmf (2A mn) 1 112'138 m4 or less o Additional nails it required. } 1—1,(25 nrn) 1'[25 mm]- 518'{16 rrm) 8 5i8' (22D mm) co ci ci 1'f25 mm�Roofing Cearenl Hip&Ridge: Option 1: For Belmont°,refer to instructions for Cedar Crest'or Cedar Crest'IR. For Belmont' IR, refer to instructions for Cedar Crest°IR. Note: The use of BASF'Sonolastic'NP1 r`adhesive or Henkel"PLO Polyurethane Roof&Flashing Sealant" in accordance with CertainTeed requirements is required for the ASTM D3161, Class F wind rating. Option 2: For Belmont': Shangle'Ridge Note: The use of BASF'Sonolastic'NP1 r"'adhesive or Henkel"PL'Polyurethane Roof&Flashing Sealant" in accordance with CertainTeed requirements is required for the ASTM D3161, Class F wind rating. 12" 181, Exposure Remove tape from the right side and fasten � SECOND Fasten the • Remove left side 85/8,FIRST � RIGHT This Tape LEFT 41 Figure 17-19:Installation of Spangle°Ridge shingles Figure 17-18:Shangle'Ridge. on hips and ridges. NEMO ETC,LLC Evaluation Report 3532.09.05-R37 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-R16 CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020 Page 10 of 14 NNEMO I etc. 6.11 CARRIAGE HOUSE®AND GRAND MANOR®: LOW AND STEEP SLOPE STANDARD SLOPE Use seven nails and three spots of asphalt roofing cement for every Use five nails for every full Shangle. full Grand Manor Shangle.Use five nails and three spots of asphalt roofing cement for every full Carriage House Shangle and Centennial Slate,Apply asphalt roofing cement 1" (25 mm)from edge of shingle (Figure 17-5).Asphalt roofing cement meeting ASTM D4586 Type tl 1" V. is suggested. �—(25 mm) (25 mm) F_ ' 11l2" 5IB'' 8 518" (38 mm) (16 mm) (220 mm) V, or less y �1 f(25 mm) (25 mm) Figure 174(Ise five nails for ever-full Grand Manor Shangle, 518 8 Sle" Carriage Flouse Sbangle;or Centennial Slate. (16 mm)j I (2�m) (25 mm)T Roofing Cement Figure 17.5:When installing Grand Manor Shangles on steep slopes, use seven nails and three spots of asphalt roofing ceinent. Hip&Ridge: Refer to instructions for Shangle° Ridge. 6.12 LANDMARK®,LANDMARK PRO,LANDMARK PRO ARCHITECT SO, LANDMARK PRO SOLARISE,LANDMARK PREMIUM,LANDMARK SOLARISE,LANDMARK SOLARISO IR,LANDMARK SOLARIS®GOLD/PLATINUM OR NORTHGATEO: AIEL RAILING 12" 14&A' Q, A'lEA I+ i3a5 mm) P75 mm) (3r75 mm}�1 T haifrg_r is Lppe'natlne I nwer nailIre Haling areas for low and standard slopes(from 2:12la 21:12) Nat uetm en upper. kswe•i'ES aS S)ftn ahOv6. STEEP 12" 14-3W' 12" SLOPE I—(305 mm)— (375 Mrrr— —(305 mm}--I NAILING IV2ilin nits RE° hero ewer mm) nor Ilpes. 1"(25 ml } { t t Roo ing Cement Hailing areas for steep slopes(greater than 21-12) and"Starnt-Nailing" %a 1,�e'ween Ic-Ner 2 nail lines as shown above. NEW ETC,LLC Evaluation Report 3532.09.05-11117 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-R16 CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020 Page 11 of 14 NNEMO I etc. Hip&Ridge: Option 1: Refer to instructions for Cedar Crest®or Cedar Crest®IR. Option 2: NorthGate°Accessory or Shadow Ridge" Note: The use of BASF"Sonolastic°NP1'""'adhesive or Henkel"PLO Polyurethane Roof& Flashing Sealant"in accordance with CertainTeed requirements is required for the ASTM D3161, Class F wind rating. (Use of sealant is optional for Shadow Ridge°produced in Oxford, NC.) 915116'{125 mrni 13 118" t —(333 mm)— Cdrteling Nafch +6 5/8"-. 6 5/8' (168 mm) (168 mrn) I (331 Irn"i Align these T Centering Notch narthex to top 13114" R edgs 41 (194 mm) (337 mm) \Alig n these/ I]r9vipU#odurs9 7 5/8" notches to top (194 mm) edge of previous course. NorthGate®Ridge NorthGate®Accessory 12'' 97/8" (305mm) (250mm) 6 6 415116" 415116 (150mm) (150mm) (125mm) (125mm) Notch for Notch for Centering Centering 12" 131/4" *,\ /1 (305mm) Notches for Alignment to 7" (337mm) NotchesforAlignmentto 5 the Top Edge of the Previous (180mm) the Top Edge of the Previous (196m8m) Cap for s"(125mm)Exposure � Capfor55(8''(141mm)Exposure English Dimension Metric Dimension Shadow Ridge® Shadow Ridge® 12" (305mm) Laying Notch I II III II 5.,(125rrw) Exposure Figure 13-20:Use laying notches to center shingles on hips and ridges,and to locate the correct exposure. NEW ETC,LLC Evaluation Report 3532.09.05-1137 Certificate of Authorization#32455 7Te EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-1116 CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020 Page 12 of 14 NNEMO etc. 6.13 LANDMARK®TL: LANDMARK TL LANDMARK TL 13112 13" 13112' (343 mm) (330 mm) (343 mm) 13112" 13" 13112" 1—(343 mm)— ---(330 mm)——(343 mm)- j �-1''(25 mm) 1"(25 mm)� I I 1"(25 mm) 1"— I� F1 1" (25 mm) (25 mm) Roofing Cement Figure 13-4:Use four Hails for eregfidl Sbingle. Figure 13-5:Use six nails andfour spots of asphalt roofing cement on steep slopes. Hip&Ridge: Refer to instructions for Cedar Crest®,Cedar Crest°IR, NorthGate®Accessory or Shadow Ridge®. 6.14 PRESIDENTIAL SHAKE®,PRESIDENTIAL SHAKE®IR,PRESIDENTIAL SHAKE°TL,PRESIDENTIAL SOLARIS11: LOW AND STANDARD SLOPE: STEEP SLOPE: For low and standard slopes,use five nails for each full Presidential For steep slopes,use nine nails for each full Presidential shingle and shingle as shown below. apply 1"diameter spots of asphalt roofing cement under each shingle tab. After applying 5 nails in between the nailing guide lines,apply 4 nails 1" Nailing 40" above tab cutouts malting certain tabs of overlying shingle cover nails. Guide Lines (1016 mm) 51l4" (133 mm) 14 1/4'' L 1 112" 38 mm)?LFil I (362 mm) T NOTE:Apply nails on painted guideline. Figure 16-6.Fastening Presiden hat and Presidential H Shake 1"diameter asphalt roofing cement shingles on low and standard slopes. Figure 16-7:Fastening Presidential and Presidential T/L Shake shingles on steep slopes. Hip&Ridge: Refer to instructions for Cedar Crest°or Cedar Crest° IR. NEMO ETC,LLC Evaluation Report 3532.09.05-11137 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-R16 CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020 Page 13 of 14 NNEMO I etc. 6.15 HIGHLAND SLATE®: LOW AND STANDARD SLOPE: STEEP SLOPE: Use FIVE nails and EIGHT spots of asphalt roofing cement*for each �w min) 23fl min) 123o min) 123o min 1 full Highland Slate shingle.For Miami-Dade,SIX nails are required. Apply 1"diameter spots of asphalt roofing cement under each tab 1„ 1„ corner.Asphalt roofing cement meeting ASTM D4586 Type II is suggested. (2S min) (25 min) 12ao min) laao min) 123o min) 123om� 9-8f8" (240 mm) (261mm) (251mm] Miami-Dade requires SIX nails(two nails 1" 25 min 8-318, ( } Miami-Dade requires (240 mm) installed over center six naiis(two nalls 1"(ssmm) cutout as shown}. Installed over center i� cutout as shown). —— Roofing Cement Figure 11-3:Use FIVE nails far every Highland Slate shingle. Figure 113d:Use FIVE nails and eight spots of asphalt roofing cement under each tab corner. *CAUTION:Excessive use of roofing cement can cause shingles to blister. Hip&Ridge: Refer to instructions for Cedar Crest®,Cedar Crest®IR or Shangle Ridge®. 6.16 PATRIOT: LOW AND STANDARD SLOPE STEEP SLOPE Use FOUR nails for every full shingle located as shown below. Use FOUR nails and four spots of asphalt roofing cement for every full shingle as shown below.Asphalt roofing cement meeting ASTM D4586 Type 11 is suggested.Apply 1"(25 mm)spots of asphalt roofing Sealant cement as shown. IL___ ___ CAUTION:Excessive use of roofing cement can cause shingles to blister. 6r118' '+1'(25 min} —————— 1'(25 mrn� (156 min) t 13-1fr 13-118, 13-IT � } ------------- (Minim) (M mlp) M inn) 6-118' i i-1-(25 min) V(25 min] (156 mm) T -Rooting Cement- 08mm( ?,?min', ;348o i Hip&Ridge: Refer to instructions for Cedar Crest®,Cedar Crest®IR, Northill Accessory,Shadow Ridge®or Shangle Ridge®. g • As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. QUALITY9. UL LLC—QUA9625; (414)248-6409; karen.buchmann@us.ul.com -END OF EVALUATION REPORT- NEW ETC,LLC Evaluation Report 3532.09.05-1137 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL5444-R16 CertainTeed Asphalt Roof Shingles Revision 17:07/24/2020 Page 14 of 14