HomeMy WebLinkAboutpoly NG specsUnderground Gas Polyethylene (PE) Piping Fitting Assembly & Sizing Chart r,�m� r.eC`CC r f' Featuring the Con -Stab I.D. Seal® Fittings from Continental Industries, Inc. and Driscoplex® Performance Pipe June 2016 1 /2" CTS .625 7.0 0.090 3/4" IPS 1.050 11.0 0.095 1 " CTS 1.125 11.5 0,099 1" IPS 1.315 11.0 0.120 1-1/4" IPS 1.660 10.0 0.166 1-1/2" IPS 1.900 11.0 0.173 2" IPS 2,375 11,0 0,216 Normal Pipe Size and SDR must be used to match fittings and IPS PE pipe. Nominal Pipe Size and Min. Wall must be used to match fittings and CTS PE pipe. All pipe shall be ASTM D2513. Visit www.performancepipe,com for more information. Patent #s 5,366,260,5,692,785 & 5,853,272 2 Gastite Division • 1116 Vaughn Parkway • Portland, TN 37148 STEP 1 Verity the polyethylene (RE.) pipe being assembled is the correct size. STEP 2 Cut pipe ends square. STEP 3 Clean piping thoroughly to assure there is no dirt, grease or oil in assembly area. STEP 4 Chamfer end of pipe using Continental's chamfering tool with I.D gauge. IMPORTRANT CHAMFERup ID OF PIPE Patent #s 5,366,260,5,692,785 & 5,853,272 STEP 5 Mark the stab depth by inserting the pipe into the chamfer tool and marking the pipe at the entrance as shown. STEP 6 If using chamfer tool with ID gauge, check for proper chamfer by inserting pipe over gauge. STEP 7 Stab pipe completely into fitting entrance. STEP 8 Stab pipe completely into fitting so that the mark on the pipe is within 1/8" from the fitting entrance. STEP 9 Repeat steps 1 though 4 for all Con -Stab joints. STEP 10 To assure proper assembly and to comply with 49 CFR 192 Subpart J-Test requirements, the joint shall be leak tested. Ph: 1.800.662.0208 • Fax: 615.325.9407 • Web: www.gastite.com NATURAL . Maximum Capacity of PE Pipe in Cubic Feet per Hour with a Gas Pressure of 6.0 in. WC and a Pressure Drop of 0.5 in. WC (based on a 0.60 specific gravity gas) Tubing I Tubing Length (ft) 110 74 59 50 44 39 33 29 26 24 22 21 20 17 16 635 426 338 286 252 227 192 169 152 139 129 120 113 100 90 823 553 438 371 326 294 249 219 197 180 167 156 147 129 116 1173 787 624 529 465 419 355 312 281 257 238 223 209 184 166 2108 1415 1121 950 835 752 638 561 505 462 428 400 376 331 298 2765 1900 1526 1306 1158 1049 898 796 721 663 617 579 547 485 439 5954 3997 3166 2683 2360 2125 1801 1584 1426 1305 1209 1130 1063 935 842 Tubing. 13 12 10 9 8 7 6 6 6 5 5 5 76 67 60 51 45 40 37 34 32 30 29 27 5 4 26 25 4 24 99 87 78 66 58 52 48 44 42 39 37 35 34 32 31 141 124 111 94 83 75 68 63 59 56 53 50 48 46 44 253 222 200 170 149 134 123 114 106 100 95 90 86 83 79 376 333 302 258 229 207 191 178 167 157 149 143 137 131 126 714 628 565 479 421 380 347 322 301 283 268 255 243 233 224 1000BTUh=1CFH Maximum Capacity of PE Pipe in Cubic Feet per Hour with a Gas Pressure of 6.0 to 7.0 in. WC (1 /4 psig) and a Pressure Drop of 1.0 in. WC (based on a 0.60 specific gravity gas) MI —Tubing �®'�'� 165 111 88 74 65 59 50 44 39 36 33 31 29 26 23 947 636 503 427 375 338 286 252 227 208 192 180 169 149 134 1228 824 653 553 487 438 371 327 294 269 249 233 219 193 174 1749 1174 930 788 693 624 529 465 419 384 355 332 312 275 247 3143 2110 1671 1416 1246 1122 951 836 753 689 638 596 561 494 445 4023 2765 2221 1900 1684 1526 1306 1158 1049 965 898 842 796 705 639 8878 5960 4720 4001 3519 3169 2686 2362 2127 1947 1803 1685 1586 1395 1256 20 17 16 13 12 10 10 9 8 8 7 7 7 6 6 114 100 90 76 67 60 55 51 48 45 43 41 39 37 36 147 129 117 99 87 78 72 66 62 58 55 53 50 48 46 210 184 166 141 124 112 102 95 88 83 79 75 71 69 66 377 331 298 253 223 200 183 170 159 149 141 135 128 123 118 547 485 439 376 333 302 278 258 242 229 217 207 199 191 184 1065 936 843 715 629 566 518 480 448 422 399 380 363 348 334 1000BTUh=1CFH 4 Gastite Division • 1116 Vaughn Parkway • Portland, TN 37148 NATURAL GAS SIZING TABLES FOR PE PIPE Maximum Capacity of PE Pipe in Cubic Feet per Hour with a Gas Pressure of 8.0 in. WC and a Pressure Drop of 3.0 in. WC (based on a 0.60 specific gravity gas) Tubing Tubing Length Size 308 210 166 141 124 ill 94 83 75 68 63 59 56 49 44 1773 1205 955 809 712 641 543 478 430 394 365 341 321 282 254 2298 1561 1236 1048 921 830 703 619 557 510 472 441 415 365 329 11, IN 3275 2198 1741 1476 1298 1169 991 871 785 718 665 621 585 514 463 5885 4002 3170 2686 2363 2128 1803 1586 1428 1307 1211 1131 1065 937 843 7290 5010 4023 3443 3052 2765 2367 2097 1900 1748 1627 1526 1442 1278 1158 16623 10940 8665 7344 6459 5816 4930 4336 3904 3573 3309 3093 2911 Tubing 2560 2305 Tubing Length Size 37 33 30 25 22 20 18 17 16 15 14 13 13 215 189 171 145 127 113 103 96 90 84 80 76 72 12 69 12 279 245 221 187 165 147 134 124 116 109 103 98 94 90 67 87 393 345 311 264 232 209 191 177 165 156 147 140 134 128 123 715 629 566 480 422 375 343 318 297 280 265 252 241 230 222 991 878 796 681 604 547 503 468 439 415 394 376 360 346 333 1954 1719 1548 1312 1154 1060 970 898 839 790 748 711 679 651 626 1000BTUh=1CFH Maximum Capacity of PE Pipe in Cubic Feet per Hour with a Gas Pressure of 12.0 to 14 in. WC (1/2 psig or less) and a Pressure Drop of 6.0 in. WC (based on a 0.60 specific gravity gas) Tubing TubingLength Size 150 462 310 246 208 183 165 140 123 111 101 94 88 83 73 65 2657 1784 1413 1197 1053 948 804 707 637 583 540 504 475 417 376 3445 2313 1832 1553 1366 1230 1042 917 825 755 700 654 615 541 487 3295 2610 2212 1946 1752 1485 1306 1176 1076 997 932 877 771 694 04909 8821 5922 4690 3975 3496 3148 2668 2347 2114 1934 1791 1674 1576 1386 1248 10606 7290 5854 5010 4440 4023 3443 3052 2765 2544 2367 2221 2097 1859 1684 24918 16727 13249 11229 9877 8894 7538 6630 5970 5464 5060 4729 4451 3915 3525 Tubing • . - Size 55 49 44 37 33 29 27 25 23 22 21 20 19 18 17 319 280 252 214 188 169 155 144 134 126 120 114 109 104 100 413 363 327 277 244 220 201 186 174 164 155 147 141 135 130 589 518 466 395 348 313 286 265 248 233 221 210 201 192 185 1058 930 838 710 625 562 515 477 445 419 397 377 361 345 332 1442 1278 1158 991 878 796 732 681 639 604 573 547 524 503 485 2988 2628 2366 2006 1764 1589 1454 1346 1258 1184 1121 1066 1018 976 938 1000BTUh=1CFH Ph: 1.800.662.0208 • Fax: 615.325.9407 • Web: www.gastite.com 5 Maximum Capacity of PE Pipe in Cubic Feet per Hour with a Gas Pressure of 2.0 psi and a Pressure Drop of 1.0 psi (based on a 0.60 specific gravity gas) 1167 783 621 526 463 417 353 311 280 256 237 221 6710 4504 3568 3024 2660 2395 2030 1785 1608 1471 1363 1273 208 1198 183 1054 165 949 8687 5832 4619 3915 3443 3101 2628 2311 2081 1905 1764 1649 1552 1365 1229 12396 8321 6591 5586 4913 4424 3750 3298 2970 2718 2517 2352 2214 1947 1754 22276 14953 11844 10038 8829 7950 6738 5927 5337 4884 4523 4227 3979 3500 3151 25532 17548 14092 12061 10689 9685 8289 7347 6657 6124 5697 5345 5049 4475 4055 62923 42239 33455 28355 24940 22458 19034 16742 15076 13797 12777 11941 11239 9885 8902 4 123 111 94 83 74 68 63 59 55 53 ■vaAMEN 50 48 MiiUMIK 46 '�i 44 ® 805 1042 708 916 637 825 540 475 428 391 363 339 319 302 287 274 263 253 1486 1307 1177 699 998 615 878 554 507 469 439 790 413 391 372 355 340 327 2671 2349 2115 1793 1577 723 670 626 1420 1300 1204 1125 589 1059 558 1002 530 507 485 467 3470 3076 2787 2385 2114 1915 1762 1639 1538 1453 1380 953 1316 910 1261 872 1211 838 7544 6636 5975 5064 4455 4011 3671 3400 3177 2990 2831 2693 2572 2464 1167 2368 Maximum Capacity of PE Pipe in Cubic Feet per Hour with a Gas Pressure 1000BTUh=1CFH of 5.0 psi and a Pressure Drop of 3.5 psi (based on a 0.60 specific gravity gas) 2544 1708 1353 1147 1008 908 770 677 6610 558 517 4483454 a � 400 0J 14628 9819 7777 6592 5798 5221 4425 3892 3505 3207 2970 2776 2613 2298 2069 18966 12731 10084 8546 7517 6769 5737 5046 4544 4159 3851 3599 3387 2980 2683 27024 18141 14368 12178 10711 9645 8175 7190 6475 5925 5488 5128 4827 4246 3823 48561 32598 25819 21883 19248 17332 14689 12921 11635 10648 9861 9215 8673 7629 6870 53153 36532 29336 25108 22253 20163 17257 15294 13858 12749 11860 11128 10512 9316 8441 137172 92082 72933 61813 54370 48959 41494 36498 32865 30078 27855 26031 24500 21550 19405 5 1754 268 1543 242 205 180 162 148 137 128 721 114 109 104 100 96 1389 1177 1036 932 853 790 739 695 658 626 598 573 551 ® 2274 2000 1801 1526 1343 1209 1106 1025 958 901 853 812 775 743 714 3240 2850 2566 2175 1913 1723 1577 1460 1364 1284 1216 1156 1104 1058 1017 5822 5121 4612 3908 3438 3096 2833 2624 2452 2308 2185 2078 1985 1902 1828 7225 6403 5802 4965 4401 3987 3668 3413 3202 3025 2873 2741 2624 2521 2429 16447 14466 13027 11041 9711 8745 8003 7411 6926 6519 6171 5870 5606 5372 5163 1000BTUh=1CFH Maximum Capacity of PE Pipe in Cubic Feet per Hour with a Gas Pressure of 10.0 psi and a Pressure Drop of 5.0 psi (based on a 0.60 specific gravity gas) 529 2369 1877 1590 1399 1260 1068 939 846 774 717 670 630 554 499 20291 13621 10789 9144 8043 7242 6138 5399 4862 4449 4120 3851 3624 3188 2871 26309 17661 13988 11856 10428 9390 7958 7000 6303 5769 5342 4993 4699 4133 3722 37487 25164 19931 16893 14858 13380 11340 9974 8982 8220 7612 7114 6696 5889 5303 67362 45220 35816 30355 26700 24043 20377 17923 16139 14770 13679 12783 12032 10583 9530 72320 49705 39915 34162 30277 27433 23479 20809 18855 17346 16137 15141 14302 12676 11485 190283 127734 101171 85746 75421 67915 57560 50629 45590 41723 38639 36109 33987 29894 26919 423 372 335 284 250 225 206 191 178 168 159 151 144 138 133 2433 2140 1927 1633 1437 1294 1184 1096 1025 964 913 868 829 795 764 3154 2775 2498 2118 1863 1677 1535 1421 1328 1250 1184 1126 1075 1030 990 4495 3953 3560 3017 2654 2390 2187 2025 1893 1782 1686 1604 1532 1468 1411 8077 7104 6397 5422 4769 4294 3930 3640 3401 3201 3031 2883 2753 2638 2536 9830 8712 7894 6756 5988 5425 4991 4643 4357 4115 3908 3729 3571 3430 3305 22815 20067 18070 15315 13471 12130 11101 10281 9608 9043 8561 8143 7777 7452 7162 1000BTUh=1CFH 6 Gastite Division • 1116 Vaughn Parkway • Portland, TN 37148