HomeMy WebLinkAboutslab drawing\ ory GENERATOR / I w I x 'pror PAD THICKNESS ISOMEFRIC VIEW GENERATOR MOUNTING CONFIGURATION: GENERATOR ATTACHMENT BASE GENERATOR OR 3"x2"xY" ALUM ANGLE W/ (4) #10 SS!?:Sl SELF-DRILLING SCR TO GENERA (SEE GENERATOR SP RUBBER VIBRATIONPAD (OPTIONAL) CONCRETE PAD 6,000 PSI NORMAL WEIGHT CONCRETE MIX ATTAC VARIES SEE GENET SEE ANCHOR RUBBER VIBRAT ( OF Z X CONCRETE 6,000 PSI NOF WEIGHT CONCI NOTES: 1. V DISTANCE DEPEND ON GENERATOR BASE LENGTH, NO LESS THAN 2". 2. X DISTANCE 3" FROM UNIT EDGE TO CLIP. 3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, NO LESS THAN ANCHOR REQUIREMENTS WIND TABLE: ROAD M FOAM L..,." PRECAST PAD 32"X54"X4" (ON -GRADE APPLICATIONS ONLY) PAD DIMENSIONS: GENERAroR IT SEPARATE SUBMITTAL L CONCRETE PAD (SEE SCHEDULE FOR MINIMUM WEIGHT REQUIRED) GENERATOR 1)4" 0 ANCHOR LOCATION l.Ds^ I IF 'a I �17, W�� L---- I J } 54LENGTH HVHZ OR NON-HVHZ RISK EXPOSURE RISK EXPOSURE RISK EXPOSURE COUNTY I C D II C p III, IV C p P. BEACH 150 MPH 32.43 Psf 39.3P M Psf0 5 M4 18MPsf Psf BM 16 MPH Psf .57 F M1 6 0ROWARD Psf 0H Ps 46.70 f 56.67 Psf 16M 39.24 PIT 472Psf 175MPH 44.14Psf 53.57Psf 186MPH 49.86Psf 60.52Psf PLAN VIEW �32" WIDTH SIDE VIEW GENERATOR U, (SEE CONCRETE PAD W SCHEDULE FOR = DIMENSIONS & WEIGHT REQUIRED) 4" I n n 54" LENGTH FRONT VIEW BRAND&MODEL CAPACfIV WIDTH LENGTH HEIGHT WEIGHT MA%PRE55URE (PSF) Generac 005871 & 005883 10 KW 25.00" 48.00" 28.80" 390 lbs 42.00 Generac 005872 & 005894 14 KW 25.00" 48.00" 28.80" 439 lbs 44.50 Generac 6459, 6461, 6462 16 KW 25.00" 48.00" 28.80" 5131bs 48.50 Generac 006721 16 KW 25.00" 48.00" 28.80" 4481b5 45.DO Generac 005873 & 005895 17 KW 25,00" 48.00" 28.80" 4551bs- 45.50 Generac OD5874 & 005886 17 KW 25.00" 48.00" 28.80" 421 lbs 43.50 Generac OD5875&005887 20 KW 25.00" 48.00" 28.80" 451 lbs 45.30 Generac 006729 & 006730 20 KW 25.00" 48.00" 28.80" 516 lbs 48.70 Generac 006551 & 006552 22 KW 25.00" 48.00" 28.80" 5261bs 49.20 Kohler 14RES&20RES 14-20 KW 26.00" 48.00" 28.80" SDO lbs 47.50 Generac 7035, 7036, 7037 16 KW 25.00" 48.00" 28.80" 406 lbs. 42.50 Generac 007038 & 007039 20 KW 25.00" 48.00" 28.80" 448 lbs 45.00 Generac 007042&7043 22 KW 25.00" 48.00" 28.80" 466lbs 45.50 Generac 007176&7178 16 KW 25.50" 48.50" 28.60" 420 lbs 42.00 Generac 007209&7210 24 KW 25.00" 48.00" 29.00" 455 lbs 45.00 ANCHOR TO PAD SCHEDULE: DEWALT SUBSTRATE DESCRIPTION (2) CONCRETE: EW-B LT+ OR SCREW -BOLT+ OR (6000 PSI EQUIVALENT, 1.5" MIN.) FULL EMBED TO CONCRETE, 3" MIN. EDGE DISTANCE, 6" IN. SPACING TO ANY ADJACENT ANCHOR. NOTES: 1. ANCHOR QUANTITY PER LONG SIDE 2. EMBEDMENT AND EDGE DISTANCE EXCLUDES FINISHES, TF APP REMICABLE. 3. ENSURE MINIMUM EDGE DISTANCE AS NOTED IN ANCHOR SCHEDULE. 4. ENSURE MINIMUM SPACING TO ANV ADJACENT ANCHORS. S. FOLLOW MANUFACTURER'S IN INSTRUCTIONS TO IN ANCHORS. WIND DESIGN REQUIREMENTS - (BASED ON ASCE 7-30 & FLORIDA BUILDING CODE SIXTH EDITION (2017)) AT -GRADE SIGN METHOD ULTIMATE DESIGN WIND SPEED Vult = 175 mph (SEE TABLE) NOMINAL DESIGN WIND SPEED Vasd = 136 mph RISK CATEGORY = II INTERNAL PRESSURE COEF = N/A EXPOSURE CATEGORY = C WIND DIRECTIONALITY FACTOR Kd= o.es ENCLOSURE CATEGORY = N/A HEIGHT H = AT GROUND GUST EFFECT FACTOR = 0.85 P AT HEIGHT H qh = 56.57 Ib/ft2 FORCE COEFFICIENT Cf = 1.43 THIS WIND PRESSURE SEE TABLE GENERAL NOTES 1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE FIARIDA BUILD3NG CODE SIXTH EDITION (2017). 2. RED ST WIND I[a B DESIGN PRESSURES NDE CALCULATED MR USE WITH THIS SYSTEM SMALL BE DETERMINED UNDER SEPARATE CERTIFICATION ON A JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE (IF REQUIRED BY THE AN]). SITE -SPECIFIC LOAD REQUIREMENTS AS DETERMINED W ACCORDANCE WITH THE APPLICABLE BUILDING CODE SHALL BE LESS THAN OR EQUAL TO THE DESIGN PRESSURE "ASD" CAPACITY VALUES LISTED HEREIN FOR ANY ASSEMBLY AS SHOWN. 3. DIMENSIONS AND WEIGHT OF UNITS SHALL CONFORM TO SPECIFICATIONS STATED HEREIN. 4. UNITS MUST BE CENTERED ON PAD WITH OPPOSITE SIDES HAVING EQUAL CLEARANCE. A MINIMUM DISTANCE FROM UNITTO PAD EDGE IS SPECIFIED. 5. THE AREA UNDER CONCERETE SLAB ON GROUND SHALL HAVE ALL VEGETATION, STUMPS, ROOTS, AND FOREIGN MATERIALS REMOVED PRIOR TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY OTHERS, 6. RESISTANCE TO SLIDING OF THE PAD ON THE GROUND IS NOT PART OF THIS DOCUMENT AS SOIL CHARACTERISTICS AND PAD PLACEMENT VARIES. 7. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED &INSTALLED BY OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. 8. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OFTHIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVE$$ HARMLESS THIS ENGINEER MR ALL COST & DAMAGES INCLUDING LEGAL FEE5 & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT WHICH 15 CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 9. TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL RESPoNSIBHMY OF THE INSTALLING CONTRACTOR, CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE lam PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHALL BE THE TOLL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. 10. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE INTEG WTV OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL 8E COORDINATED BY THE PERMITTING CONTRACTOR. Il. THIS CEMENT IS GENERIC AND DOES NOT PERTAIN TO ANY SPECIFIC PROTECT SITE. INFORMATION CONTAINED HEREIN IS BASED ON COMPACTOR -SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBLE OR LGBLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. DIMENSIONS ARE SHOWN TO ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE DMIATIONS SPECIFIED HEREIN. WORK SHALL BE FIELD VERIFIED BY OTHERS PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE NOTIFIED AND GWEN AN OPPORTUNITY TO REEVALDATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS. ALTERATIONS OR DD1TtONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. 12. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. VISIT ECALC.10/162937 � � FOR ENGINEER CERTIFIED ORIGINALS 8 MORE INFORMATION ABOUT THIS DOCUMENT OR CAN THE OR CODE TO THE RIGHT> VISIT ENGINEERINGEXPRESS.COWSTORE FOR ADDITIONAL PLANS, REPORTS & RESOURCES TANK BENNARDO, P.E. -# 0046549 CA# 9885 2G ON SHEET 1. THIS SHFEEN ODES NU GINEER'S � N O t V FMPuO W FMMMy �LLMd U o SmxBe LiUm �x � ¢ UJ Os00 $wZ �I oNoMzw O W �WZ N�PwZ Fw O W �0 19-16293.1