HomeMy WebLinkAboutBuilding plansGulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two stagggered rows 12" o.c. in field. Attach
deck to trusses using attachment detall on this sheet
12
SLOPE 14
8'-1" T.O.B.
12"
5/8" thick light textured O
stucco on typical concrete
block construction
- - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - -
12"
H.
0'-0" = Finished F
H
Finish Columns with
5/8" thick cut coral
finished stucco bands
RIGHT ELEVATION
12
4 1 SLOPE
5/8" thick x 8"w cut
coral finished stucco bands
SCALE: 1/4" = 1'-0"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411651.12
26 ga. Sv crimp metal roofing attached to plywood deck using 99 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
Im
ELEVATION NOTES:
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
26 ga. 5v crimp metal roofing attached to plywood deck using 49 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
%.o.c. atlapspa�d-two �staqgered rows 12" o.c. in field. Attach
. �ni n a..uu `.vI ui 5LUCCO on Lupical concrete
flnlshed stucco bands block construction
REAR ELEVATION
- Overhangs at 1'-0" unless otherwise noted on Roof Plan
Roof pitch at 4:12 unless otherwise noted
- Ancg changes to this plan shall be submitted to the architect
for approval In writing prior to starting construction.
- Return ALL Stucco Bands Into Window or Door.
Iz"
a.HLl 5/8" thick x 8"W cut
3 coral finished stucco bands T
3
5/8" thick light textured
stucco on typical concrete
block construction
Finished Floor
LEFT ELEVATION
SCALE. 1/4" = 1'-0"
Product Approval Submittal Affidavit
Opening Schedule Swing Doors, Overhead Doors, Sliding Doors, Windows & Slwlighta
Opening
Type
NOA/FL
NUMBER
Product
Model #
Manufacturer
Glass
Attachment method
Siration
Da a
Design Pressure
g
of Approved Tests
1,2,3
t4
FLU 11499.2
Sln le Hun
g g
Seres 185
MI Windows
and doors
x gpcona nl❑ pqn�tLetlon at mex
ion .ac� corner end L o.c. [hereafter througi PT Buck into sated
Pilled CMU wall mmntammg min 2.5" edge distance n strict adherence
to the product approval.
60 of
± p
A
16-0330.02
Overhead
Garage Door
g
Model 824/811
9'-4" max. width
IL'-o" max hei ht
a
DAB
"" x = to OeAO'' eL •it • c sit
1 m5 bar vert. uang 3/e' x e Hila HLC bWva anehera at e' e.e
th 1.25' d oaMer girth min 1' edge dutenee. Install back to buck
min. (0 I . x 5%9' full thrsod ag amraua in each bracket maintaining
min ar IS' edge dmtenu - GC to stnctlp adhere to product approval
rovula l/IL' nut umher an rdler
10-9-21
+ 50.0/-60.0 psf
B
FLU 14114.1
Fiberglass
Deargm Pro/
Smooth Pro
Jeld-Wen
Elco 1/4" dia. to con with min 1.25" embedment at 3" max
corners and 17.5" o.c. max thereafter 1n head and iambs.
+ 50.0 PSF
Ifrom
C
FLU 15332.2
Sliding Glass
g
D OOf
Series 420
Mi Windows
and doors
i - x cone w enetrauon at max.
PT Burk mtonew idn R(ledp O.C.Uaimal�wmbIs Town tar ft51 edge gdiatence
n strict adherence to the product approval.
+ 48.2 PSF
-
Product
NOA/FL
NUMBER
Model #
Manufacturer
Attachment Method
EST
apiration
Date
Design Pressure
of Approved Testa
Mullions
FLU 15353.8
CM-18531
vertical mullion
Mi Windows
and doors
For CMU use (2) 1/4' x 2 3/4" tapcons with min 1 1/4" embedment
penetration into each Mull Clip. Attach mull to clip using (4) #10 x 1.25"
self tapping screws per clip as shown 1n product approval.
+ 118.9 PSF
Roof
FLU 11151.12
5V Crimp
Metal RoofingGulf
Coast Supply
and manufacturing
2L ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws sith self sealing washer at 12" o.c, max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 0 end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
synced 0 o.c, at all laps and two eta gered rows 12" c.c. in field, Attach
deck to trusses using attachment detall on roof plan
- 108.5 PSF
Siding
Stucco on Block
Soffit
FL# 12198.3
Model T4 12" vented
Vinyl Soffit
Kagcan
Install using 2" x 2" battens at 6" o.c. screwed to soffit framing using
#8 x 3" wood screws at each truss. Install soffit to battens using
0.12". x 1 Iona rino shank nails with/ dia.
+55.0/-35.0 PSF
Hurricane
Panels
FI# 15016.2
2-4 Gauge
Storm Panels
Global Protection
Products LLC
Install using 1/2" die. solid set lead anchors with 1/4" dia.-20 x 1.5"
long SS screw head combo. with Neoprene washer at 12 1/2' o.c.
along the bottom and 13" o.c. at the top
+ 45.0 PSF
I have reviewed the above and approved it by my seal below. ( Architect or Engineer of Record
5/8" thick x 8"W cut --
coral finished stucco bands
-0'-4" A.F.F.
2" x 4" top plate 11
1/2" drywall ceiling on truss bottom cord
1/2" drywall on
2" x 4" studs at W' o.c.
base -board 11 11 ,, 2" x 4" P.T. bottom plate
\ 4" concrete slab with fibermesh OR
6"x6" 410/10 WWM on 6 mil Vlsqueen over
clean compacted termite treated fill
Interior Non-Bearinq Partition
Braden t
Braden AIA, PA
Architects
- Planners
411
S.E. Coconut Avenue
Tel
: (112) 281-8258
Fax
: (112) 281-8283
E-mail:
bradenalaacomcast.net
Stuart, FL
34994 UAAC000032
L
SCALE: 1/4" = 1'-0"
Gulf Coast 5upplu, and MFG 5v Crimp Metal roofing FL #11651.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
a! i F-0 dw�
NO
5/8" thick light textured
stucco on typical concrete
block construction
FRONT ELEVATION
Wynne Building Corp.
The Grard Carlton
Spanish Lakes
St. Lucre County Florida
If 7eq- a trz
'ST. LUC)F COt"YTY PI'II.niNc PT!�feiON
REVIEWED FOR C L E
REVIEWED �i'
DATE
PLANS AND PERVfI NfUST BE KEPT ON
OR NO INSPECTION WILL BE MADE.
/8" thick x 8"W cut
Dral finished stucco bands
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES,
TERMITE TREATIVIENVi REQUNRiiD
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESAf)NS111lilYOFTHE
CONTRACTOR OF RECORD
ALL ComiRNg E
�VI1H ABC ENVOY CODE MUg1' E
REMAIN ON ALL DOORS AND WINDOWS
UNTIL INSPECTIONS ARE APPROVED
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of 15 lb felt using 8d nails. Substrate
to be 19/32" COX Plgwood nailed at 6" o.c.
in field and edges with IOd ring shank galvanized
nails into truss webbing.
0WA
O
thick x 8"w cut
coral finished stucco bands
SCALE: 1/4" = 1'-0"
Finish Columns with
5/8" thick cut coral
finished stucco bands
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION (FORM 100)
Florida Building Code Residential: 5th Edition and ASCE 1-10 for Wind Loading
Building Design is: Enclosed Risk Category: II Wind Velocity: 11.5 mph ultimate
Mean Roof Height: I'- " Roof Pitch: 4:12
Internal Pressure Coed` lent: ±0.18
SubJectabdity to damage from: Weathering: Negligible Termites: Verg Heavu
Width of Roof End Zone: V-4" Wind Speed: 145 mph ultimate
Wind Exposure Classification:C 1.21 x O.9 = 0.124 ASD design
Adjustment factorforfor Exposure Height.
Load Combination: ASCE 1-10 Section 2.4 DL+LL; DL+O.6WL; 0.6DL+0.4L0L
Components t Cladding Wind Pressure (NET) Roof Zone.. I. +20.6/-32.t psf
Roof Zone: 2. +20.6/-51.0 psf
Roof Zone: 3. +20.4/-84.0 pair
Components t Cladding Wall End Zone Width. '-4"
Components t Cladding Wind Pressure (NET) Wall Zone: 4. +35.8/-38.1 psf
Wall Zone: S. +35.8/-41.8 psf
Components t Cladding Wind Pressure (NET) on Garage Door: +32.0/-40.3 psf
Shear Walls Considered for Structure? Yes
Continuous Load Path Provided? es
Are Components an Cladding Detai s Provided? Yes
Minimum Sal Bearing Pressure:2,500 psi, Presumptive: X By Teat: psi
This Building Shall Have the Following:
APPROVED SHUTTERS: X IMPACT GLASS: BOTH: NEITHER:
ROOF LIVE LOAD: 3'11 psf ROOF DEAD LOAD: 10 psf
FLOOR LIVE LOAD: J5 psf FLOOR DEAD LOAD:10 psf
NIP R O� 2.12
TO L. PITCH
0 = Roof Zone I
Walls Zone 4
EM = Roof Zone 2
Walls Zone 5
END ZONE
= Corner Zones
Roof Zone 3
JOB ADDRESS:
Date Drawn Revisions Sheet Comm #
5-9-11
GARAGE Drawn by:
LEFT _ 12 - 2
C.C.U.
Checked by:
D.R.B. OF 5