Loading...
HomeMy WebLinkAboutBuilding plans ,pg 2FLOOD' fLAN CRASH POST DETAIL TYPICAL NOTES: SCALE 1/4" = 1'-0" I. Contractor to verify ALL notes and dimensions prior to 31" high by 4" diameter steel crash post. Floor proceeding With Work. Flange with 4 - 3/8" 2_ Contractor to STRICTLY enforce ALL OSHA Requirements. ex anslon bolts Into 3. ALL Lumber to be used as Beam, Rafters, etc... to have slag (3/8"t 50 ksi steel plate) a minimum 1,400 P.S.I. fiber stress. L" 4. No dissimilar metals to touch. 2,," 2,," S. ALL Concrete used for slabs shall be min. 2,500 PSI concrete, %" ALL Concrete used for vertical filled cells, cont. tie beams etc_ to o shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix m 6. Drywall at ceilings shall be leveled and attached to bottom chord E of trusses with screws per FBC R­102.3.5. 1. ALL wood in contact with concrete shall be pressure treated. 0 8. ALL Wall dimensions are nominal and not finished wall or stud dimensions. 9. ALL plumbing fixtures to be low flow. 10. Contractor to Provide Drain at water heater in accordance with the current edition of the Florida Plumbing Code. 11. Contractor to Provide a 2'-8" wide door at one bathroom for handicap accessibility requirements. 12. Lowest finished floor to be set by Governing Building Department surveyor to set in field. 13, Separation between residence and garage shall be per FBC R302.6 14. Door between garage and residence shall be 1-3/4"t 20 min, rated door W� = Water Heater 15. Wall and Ceiling shall have a flame -spread classification of not greater than 200 per FBC R302.9.1 16. Wall and ceiling finishes shall have a smoke -developed index of not greater than 450 per FBC R302.9.2 11. All exposed attic insulation materials installed on attic floors shall have a critical radiant flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation I" x 6" P.T. Buck nailed to block with case hardened nails materials exposed on the underside of the roof deck or on the attic walls shall comply prior to door attachment with F.B.C. R316 - see permit Info box of code edition 18. Gypsum board material shall conform to ASTM C36, C19, C415, C514, C630, C931 CcroO, C1002, C1047,C1111, CI118, C1218, C1395, or C1396 and shall be installed V ? according to the following: (FBC R102.3.5) Drywall Thickness Location Orientation Framing Se Maacximuinr m Max. spacing of fasteners Nall sizing options for installation of drywall into wood framing members 2" x min. thickness Nails Screws Ceiling Perpendicular 24" 7 12n 13ga 1 3/8" long with 19/64" head �2 " 0.098" diameter x 1 1/4" long annular -ringed or 5d cooler nail OR 0.080" dia. x 1 5/8" long with I5/64" head Walls Either Direction 16" 8" 16" OR Ggpsum board nail 0.086" dia. x 15/8" with 9/32" head. Ceiling Perpendicular 241, 1" 12" 139a 1 5/8" long with 19/64" head e" OR 0.098" diameter x 1 3/8" Ion g annular -ringed or lid cooler nail OR 0.092" dia. x 1 1/8" long with 1/4" head Walls Either Direction Ili,, 8" 16" OR Ggpsum board nail 0.0915" dia. x 1 �/8" with 19/64" head. Install SGD thru buck into block with 3/16" tap -con with -_ 1 1/2" penetration at 6" o.c. max. from each corner and 20." o.c. max thereafter at head per product approval Use 3/16" tap -con with 1 1/2" penetration at 6" o.c, max. from each corner and 20" o_c. max thereafter at sill per product approval 19. ALL ceramic tile surfaces installed shall conform to ASTM A108.1 thru A108.6, A108.1, A118.1, A118.3, A13(.l and A131.1 20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM C1288, C1325, OR CII-18 and installed I.A.W. manufacturers recommendations shall be used as backer for the wall tile in tub areas and wall panels 1n shower areas. 21. Insulation including facings such as retarders or vapor permeable members installed within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics shall have a flame spread index not to exceed 25 with an accompanying smoke developed index not to exceed 450 when tested in accordance with ASTM E 84. Insulation shall comply with F.B.C. R316. Grade Gulf Coast Supply and MPG 5v Crimp Metal roofing FL #11451.12 26 ga. 5v crimp metal roofing attached to plywood deck using 49 x 1.5" wood screws with self sealing washer at 12" o.c, max spacing over ASTM D (type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails spaced 6 o.c. at all laps and two staggered rows 12" o.c. in field. Attach deck to trusses using attachment detail on this sheet \ Simpson HETA 20 or equal hurricane anchor at each truss 12 with (10) lod x 1 1/2" nails PRE-ENGINEERED TRUSSES ! 24" o.c.) supporting Max. 4 F at 24"o.c. TYPICAL 18101bs. uplift �\ (shop drawings by manufacturer) Aluminum Drip V Edge t Fascia V-1/2' " \R-30 blown fiberglass in bottom chord of trusses drywall with smooth finish 2" x 6" Sub -Fascia Kaycan full o vent vin9l soffit installed using 1/8' dia shank x 15" long gals. roofing nails with 3/8" dia. head per product approval - see chart sheet #1 Two rows of beam block filled with concrete and (1) #5 bar cont. in each row. Substitute precast lintel filled with concrete and (1) #5 bar cost. for bottom row over openings I/2" dr wall over I" x furringg strips at Ili" o.c. with R4.1 frfoil on typical 8" Block walls '-insulation 5/8" thick light textured stucco on typical concrete block construction - M All drywall to be installed per FBC R102.3.1 and shalt meet all pertaining ASTM codes. Mortar to be Type "M" only proportioned per FBC R601.1 and Mortar Jonts shall comply with FBC R601.2.1. Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...) 45 bar vert. w/ 30" overlap Fill cell with concrete and at each filled cell Wood Base (I) 45 bar vert. (typical). Max. spacing shall not exceed 48" unless otherwise noted see foundation plan notes for spacing at openings 4" concrete slab with fibermesh OR 6"x4" 410/10 WWM on 6 mil Visqueen over clean compacted termite treated fill IIII-IIII I I _IIII i l- ;: , '-IIII-IIII TYPiCAL SEC71ON 14" x 14" Concrete footing with (2) #5 bars cont. and 95 transverse bars at 48" o.c. Scale : 1/2" = 1'-0" N.T.S. AREA CALCULATIONS Living A/C = 144L sq. ft. Front Porch = I-4I sq. ft. Rear Porch = 200 sq. ft, Garage = 321 sq. ft. Total Under Roof= 2108 sq. ft. Total Cubic Ft = 11,568 O 2• VTR JIL .. I 2%' I 0 I 21" VTR Masterr�� JAL Bath 1 I L v. rl v 2- Ln. 1 I 2" VTR W.C. I J L 3• I I 2' 3. Shur. I Kit. sink I I Kitchen 2 I I Lev. ri Masonry Beam S. " O'1to Head fixed door sliding door 1 1/2" DOLLom i racK �I Sill Sliding Door Detail At Masonry Wall NTS w.c. Bath #2 Shur. 3" C.O. To Septic PLUMIBING RISER I" x 6" P.T. Buck nailed to block with case hardened nails prior to door attachment Masonry Wall cal Flooring Install SGD thru buck into block with 3/14" tap -con with 1 1/2" penetration at 6" o.c. max. from each corner and 20." o.c. max thereafter at Jambs per product approval Jamb Window Schedule Mark Size Rough Open, Window Description PRESSURE ZONE I. 4'-Ska"x 5'-3%" 54%s"x 43/4" Single Hung ZONE 4 2. 6'-2%a"x V-3 /a' l5" x 63 /4" Single Hung ZONE 4 3• 2'-2" x 3'-2 1/2" 2l%2"x 38%" Single Hung ZONE 4 4. 4'-54"x 4'-2/a" 54ia"x 54Ys" Single Hung ZONE 4 ALL Windows to be aluminum windows w/ tint and mullions per elevations. ALL windows to withstand pressures in permit info box on sheet I ALL windows In bathrooms to be tempered All rough opening dimensions to be verified by contractor with manufacturers specs prior to construction r Door Schedule Mark Size Rough Opening Door Description PRESSURE ZONE A 9'-o" X l'-O" 108" x 84" Overhead Garage Door ZONE 4 B 3'-0" X 6'-8" 41 %4"x 83%4' Fiberglass Panel - Inswing ZONE 4 C 6'-O" X 6'-8" l4" x BI %2" of r e:te'" Sliding Glass Door ZONE 4 D 2'-0" X 6'-8" Solid Core - Wood - 6-Panel -Bi-Fold Finished 24" x 81 %2" E 2'-6" X 6'-8" Solid Core - Wood - 6-Panel F 5'-0" X 6'-8" Solid Core - Wood - 6-Panel - Bi-Fold G 2'-8" x C-8" x 1 %" Solid Core Wood, Steel, or Masonite Door H 2'-8" X C-8" Solid Core - Wood - 6-Panel J 2'-6" X C-8" Solid Core - Wood - 6-Panel - Bi-Fold K 2'-8" X C-8" Solid Core - Wood - 6-Panel - Bi-Fold ALL Exterior doors to withstand pressures stated in permit info box on sheet 1*I GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET 41 All rough opening dimensions to be verified by contractor with manufacturers specs prior to construction Install windows thru buck into block with 3/1V tap -con with 1 1/2" penetration at 6" o.c. max. from each corner and 20." o.c. max thereafter at ambs and 20" o.c. max. Exterior face at head and aid per product approval of wall ----\ \ Buck to be I" x 4" PT P.T. Buck nailed to block with case hardened nails D e t a l l a t W i n d OW S prior to window attachment Braden t Braden AIA, FA Architects - Planners 411 S.E. Coconut Avenue Tel : (112) 281-8258 Fax : (112) 281-8283 E-mail: bradenaia8comcarlst.net Stuart. FL 34994 UAAC000032 NTS Wynne Building Corp. The Grand Carlton Spanish Lakes St. Lucie County Florida 14'-O" 34'-O" al< 9'-6" 1 121i 8'-6" _112"1 EINSTA:LL VULKEM BLOCK SEALANT JAMB, HEADER, AND OCK PRIOR TO BUCK LATION GARAGE LEFT Date Drawn 5-9-I1 Drawn by: C.C.U. Checked by: D.R.B. Exterior face of wall ---\ Attach buck to block wall with 1/4" dia. Elco comic screws with min. 1 1/4" penetration at 12" o.c. max and 4" max from each corner thru 2" x 6" PT Buck Detail at Door Revisions #8 wood screws thru jamb into bu at each hinge and 15" o.c. max an prior to door attachment NTS Sheet I Comm ii 2. 1"T2t=u4 2 � OF 5