BLOWER DOOR TEST FORM Permitting Department
House Infiltration Test Certification St. Lucie Countv
Prescriptive and Performance Method
Date: 2e I.' Permit#: S L o n 28 2
Contractor: W Q_V`z1 M
Job Address: `f `f- 1 S 64 I r a A
Construction: New Construction—Complete ( ) Existing—After Addition
House Infiltration Test_Results SLC Climate Zone 2 f
CFM(50)= f 4-5--( Test Date:
Volume= 1-5 -8
ACH(50)=CFM(50)x 60/Volume= .5-5 Mechanical Ventilation required less than 3 ACH
Passing results must be&ACH(50)or less 1>40ass ( ) Fail
FBC,Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5)or(7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f),(g)or(i)or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC,Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w.c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole-house mechanical ventilation in accordance with Section M1507.3:
Testina Comi)anv
Company Name: Pro-Duct Services Address: 1915 Rio Vista Dr., Ft Pierce 34949
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Se tion 402.4.1.2 Climate Zone 2.
Signature:
Printed Name: Martin Klein
License/Certification#: 5061633
_ I
BUILDING PERFORMANCE INSTITUTE, INC.
107 Hermes Road,Suite 210 ;`
Malta, NY 12020
(877)274-1274
www.bpi.org -
Martin Klein
BPI } BPI ID#:5061633
(SEE REVERSE SIDE FOR DESIGNATIONS AND EXPIRATION DATES)
CERTIFIED PROFESSIONAL DESIGNATION EXPIRATION DATE
Infiltmdon&Duct leakage(IDL) 4/26/2021
BUILDING PERFORMANCE INSTITUTE, INC.
I '
RECEIVED
Planning &Development Services
Building &Code Regulation Division SEP 19 2300 Virginia Ave 7n1A
• - f D - Fort Pierce, FL 34982 Permitting De
' 772-462-2172 Fax 772-462-6443 St juCie C04MP4artr r:
CERTIFICATE OF TERMITE TREATMENT
CONSTRUCTION SOIL TREATMENT
PERMIT #: 1709-0282 JOB ADDRESS: 14415 DALIA FORT PIERCE,FL 34951-2811
BUILDER/CONTRACTOR: WYNNE DEVELOPMENT
PEST CONTROL CONTRACTOR: EVICT-A-BUG TERMITE&PEST CONTROL INC.
PEST CONTROL LICENSE #:JB175775
We,the undersigned, hereby certify that we have pretreated the above described construction for
subterranean termites in accordance with the standards of the National Pest Control Association.
Square feet if area treated: 200 LF Chemicals used: DOMINION 2L
Percentage of solution: -05% Total gallons used: 100
• 04-24-2018 • 1.30
Date of Treatment. Time of Treatment.
Footing Slab
1st Treatment 1st Treatment
Re-Treat Re-Treat
Driveway Pools
1�Treatment 1st Treatment
Re-Treat Re-Treat
Other xxxxx Perimeter fo al Inspection
1st Treatment
Re-Treat 9-18-2018
Signature of Exterminator Date
Note: There must be a completed form for each required beabnent or re-beabnent and this form must be on the job
site to be picked up by the inspector at time of each inspection.or Me scheduled inspection will fail and a re inspection
fee charged.
FBC104.2.6 Certificate of Protective Treatment for prevention of termites A weather resislantjobsite posting board
shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed,
providing a copy for the person the permit is issued to and another copy for the building permit files The Treatment
Certificate shall provide the product used,identity of the applicator, time and date of the treabnent,site location,area
treated,chemical used,percent concentration and number of gallons used, to establish a verifiable record of
protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall
be completed prior to final building approval.
St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on
the electrical panel box cover, listing all the treatments and dates of applications.
Revised 7/24/2014
� p1��7q. S:evpl? noir'�t- ervice 4110
do r '' ocle' ti �iv�sia�ltt P Z x: t?
l
St 4
F+�r.�'PWe * Ft 82 a����en',
. - paxT724Z � 4 .172-462-' - 6
R-equ'estfor 30-DayTemp my Power'Rdease
Date: `6� ��� Peril_INftber. Nn( Y\--C h %
Project Adder: � �-�� Q�G
THE UNDERSIGNED HEREBY REQUEST RELEASE of ELEC[RICAL POWER TO THE ABOVE DESCRIBEDPROPERTy, FOR A PLOD NOT'T4 EX EW THIRTY.(30) DAYS,FOR THE PURPOSE OF TESMG SYSTEMS
AND EQUIPMENT IN PREPARATION FOR,A PIMA L.INSPEMON. IN WNSIDtRATION OF APPROVAL OF THE
REQU9ST wE•HEIR`ACKl11OV6 umtjE ANb AGREE A FdLIoWS:
1. This temwrary power release is ro4pesWd for the above staled purpose only,and there will he m
Occupancy of any tVM ether than that perMitted by consixuction during this time period.
2. As witness by.our signattit 5,we heretiy-agree th abide by all terms and conditions of this agreement,
including Building Division Policy,which is incorporated herein by reference.
3. All conditions'and t uiremen listW in Vie attached document erMed"Requirements for 30 ley
Power WTesiyAV hW been fulfilled•arid the prreml5e is ready for compliance inspection.
4. All requests for ars ext anion beyond 30 days.must be:made in wnUn,g t D the Building'OfFKial sating
the reason fnr the request. Power maybe mmoved•from the site and[or ar Stop Wor K Order issued if
the Final'Inspedion has not been approved within 30"days. A tee of$100.00 will be required to EiFt
the Stop Work Order.
WE HMZFE1!RELEASE AND AGREETO HOLD HARMLESS,ST. WaE COUNTY,AND THEIR EMPLOYEES FROM
ALL LI 4BILITIES ANQ.aims&ANY TY E:00 NATURE 1EVKCH MAY AMSE NOW OR IN THE FUTURE OUT
OF`THIS TRANSACTION,Ii11t [:UI ItV AN'Y DAMAGE.WHICfi:MAY BE INCURRED.DUE- O THE
D ON IECi"fON ELECTRI IL Pp11lYE#t IN THE Eti EW OF VIO[.A17ON OF THIS AGREEMENT:
OWNER'SIGNATURE • DA7E
GEN NTRAC= N DATE
i
F.I.EC{RzcAL CoRmcroR SIGNATURE DATE
££6-1 £000/LOOOd 08-1 999L8L83LL £9=£L K,12-80
it '
RECEIVED
JUL 10 7018 .Professional Insulators of South Florida
Permitting Department FTC Insulation Installation Certificate
St.Jude qIr!l3ty St Lucie Count3i Date: June 25,2018
Re:. Lot/Block:
Address: 14415 Dalla Project:
The undersigned hereby certifies that insulation has been installed in the above described property as follows:
1. Exterior CBS walls have been insulated with: Spray-on Cellulose
Thickness in inches: lFiberglass Blankets
Manufacturer: Fi Foil Rock Wool Blankets
Density: X Aluminum Foil
R Value: R 4.1 Rigid Board
Polystyrene
Other
2. Ceilings(level)have been insulated with: Spray-on Cellulose
Thickness in inches: 11.1" X Fiberglass Blown
Manufacturer: Climatepro- Rock Wool Blankets
Density: Aluminum Foil
R-Value: R-30 I jPolyurethane
O en Cell SPF
Ceilings(Inaccessible)insulated with: Spray-on Cellulose .
Thickness in inches: 9.5" X Fiberglass Blankets
Manufacturer: Johns Manville Ignition Barrier
Density: Fiberglass Blown
R-Value: R-30 Cellulose Loose Fill
Open Cell SPF
3. Interior kneewalis have been insulated with: Fiberglass Blankets
Thickness in inches: Fiberglass Loose Fill
Manufacturer: Rock Wool
Density: Fiberglass Blo
R-Value: Cellulose
Open Ce
4. Garage partition walls of A/C living area have X Fi a
been insulated with: Rock of
Thickness in inches: 3.511 Polyur
Manufacturer: Johns Manville Spray-on o
Density: Open Cell SP .
R Value: R-11
5. The following have been insulated:
io
WYNNE BUILDING CORP. A s
General Contract/Builder !�
a :i
:9603
CBC1254041 %r,�•;• :3Competency#
�'b.`
r*� .r.•Vi<!{��.ems. �`�► '
Professional Insulators of South Florida,Inc.
Insulation Contractor
By: AW
By:
• I
Planning &Development Services
Building &Code Regulation Division
® 2300 Virginia Ave
• o Fort Pierce, FL 34982
772-462-2172 Fax 772-462-6443
CERTIFICATE OF TERMITE TREATMENT
CONSTRUCTION SOIL TREATMENT
PERMIT #: i Z JOB ADDRESS: l' v 3 n5t
BUILDER/CONTRACTOR: j e
PEST CONTROL CONTRACTOR: EVI -A-BUG TERMITE&PEST CONTROL INC.
PEST CONTROL LICENSE #: JB175775
We, the undersigned, hereby certify that we have pretreated the above described construction for
subterranean termites in accordance with the standards of the National Pest Control Association.
Square feet if area treated: n) Chemicals used: DOMINION 2L
Percentage of solution: .05% Total gallons used: I
Date of Treatment: MZ%6� Time of Treatment: 30
Footing Slab
1st Treatment 1st Treatment
Re-Treat Re-Treat
Driveway Pools
Y' 1st Treatment 1st Treatment
Re-Treat Re-Treat
_Other ,a ro Perimeter for Final Inspection
1st Treatment
Re-Treat
'-'siSig ture of Exterminator Da e
Note; There must be a completed form for each required treatment or re-treatment and this form must be on the job
site to be picked up by the inspector at time of each inspection or the scheduled inspection will fail and a re-inspection
fee charged.
FBC104.2.6 Certificate of Protective Treatment for prevention of termites A weather resistant jobsite posting board
shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed,
providing a copy for the person the permit is issued to and another copy for the building permit files The Treatment
Certificate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area
treated, chemical used,percent concentration and number of gallons used, to establish a verifiable record of
protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall
be completed prior to final building approval.
St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on
the electrical panel box cover, listing all the treatments and dates of applications.
Revised 7/24/2014
Planning &Development Services
Building &Code Regulation Division
® 2300 Virginia Ave
Fort Pierce,, FL 34982
772-462-2172 Fax 772-462-6443
CERTIFICATE OF TERMITE TREATMENT
CONSTRUCTION SOIL TREATMENT "/���
PERMIT #: D 2-$,2` JOB ADDRESS: Pat ),=�
BUILDER/CONTRACTOR:
PEST CONTROL CONTRACTOR: EVICT-A-BUG TERMITE&PEST CONTROL INC.
PEST CONTROL LICENSE #: JB175775
We, the undersigned, hereby certify that we have pretreated the above described construction for
subterranean termites in accordance with the standards of the National Pest Control Association.
Square feet if area treated: Sri'g s/1- Chemicals used: DOMINION 2L
Percentage of solution: .05% Total gallons used: �19 5
Date of Treatment: / g Time of Treatment: . q /--�
FootingSla
11t Treatment _Ist Treatment
Re-Treat Re-Treat
Driveway Pools
1st Treatment 1st Treatment
Re-Treat Re-Treat
Other Perimeter for Final ection
1st Treatment
Re-Treat
Signature of Exterminat Date
Note. There must be a completed form for each required treatment or re-treatment and this form must be on the job
site to be picked up by the inspector at time of each Inspection or the scheduled Inspection will fail and a re Inspection
fee charged.
FBC104.2.6 Certificate of Protective Treatment for prevention of termites A weather resistantjobsite posting board
shall be provided to receive duplicate Treatment Certlflcates as each required protective treatment Is completed,
providing a copy for the person the permit Is issued to and another copy for the bullding permit files Tire Treatment
Certificate shall provide the product used,Identity of the applicator, time and date of the treatment,site locatlon, area
treated, chemical used,percent concentration and number of gallons used, to establish a verifiable record of
protective treatment. If the soil chemical barrier method for termite prevention Is used, final exterior treatment shall
be completed prior to final bullding approval.
St(Lucie County requires for the final inspection for CO.. a Permanent Sticker to be placed on'
the electrical panel box cover, listing all the treatments and dates of applications.
Revised 7/24/2014 '
• i i
IL 9
AVjL
LLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC.
MARTIN (772)337-7755 P.O. BOX 78-1377 SEBASTIAN FL 32978-1377 SEBASTIAN (772)589-0712
PALM BEACH (561)845-7445 www.ksmengineering.net MELBOURNE(321)768-8488
FAX(561)845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE(772)229-9093
C.A.:5693 FAX(772)589-6469
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 2922
DATE TESTED December 22, 2017 KSM JOB# : 173863-1 d/SF/cv
PERMIT# 1709-0282
CONTRACTOR Wynne Development
JOB LOCATION 14415 Dalia Avenue
Spanish Lakes Fairways
Fort Pierce, Florida
ITEM TESTED Compacted Foundation Fill
TEST LOCATION DEPTH * PEN DRY MAX. DRY PERCENT
OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION
1. S.E. 0" - 12" 48 108.1 110.9 97.5
2. S.W. 45 106.7 if96.2
3. Center 45 105.9 it 95.5
4. N.E. 47 107.9 It97.3
5. N.W. 46 107.1 96.6
Soil Description:
Brown Sand with 112.0 I I I I 1
Traces of Clay W I I I I I I
In Place Moisture: E I I I I I I
9.4 Percent I 111.0 ..—.._
G I I I I I I
Optimum Moisture: H
12.0 Percent T I I I I I
110.0 —.._.1_.._.' _.._I._.. _.. .._.._
Max. Dry Density: P I I I I I I
110.9 P.C.F. I I I I I I
C 109.0
@ Test Locations The
I—.._.j_ ._.�._.._f._..�.. ..—.._
Density & Penetrometer F I I I I I
Readings Indicate the I I I I
Degree of Compaction Meets 108.0 •I•— —
Minimum Required D I I I I I
115111
6�agation. R Iti
e en to Natural Grade. Y 107.09 1 15
No. Mei2ule e6ller P
V F 'den : , ; Department
`.`�ucie County Building Department COuntYrFL
� 6 anlshlakes.com
�,�181888161Its%% Ronald G. Keller, P.E.: 37293/SI Lic. No.: 860 ! Julie E. Keller, P.E.: 68366
12/27/2017 16:03 7725896469 KSM ENGINEERING
PAGE 01/01
I
Walks .
J&1JAW
KELLER, SCHLEICHER & MacWILL1AM ENGINEERING AND TESTING, INC.
MARTIN(772)337-7755 RO, BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN(772)589-0712
PALM BEACH(661)845-7445 www.ksmengineering.nat MELBOURNE(321)768-8488
FAX(561)845-8876 E-Mail_KSM@KSMENGINEERING.NET ST• LUCIE(772)229-90�
C-A.:5693 FAX(772)589-64i 9
SOIL COMPACTION REPORT �
ASTM D 1567 and ASTM D 2922
DATE TESTED : December 22, 2017 KSM JOB#: 173863-1d1SFlcv
PERMIT# 1709-0282
CONTRACTOR Wynne Development
JOB LOCATION 14415 Dalia Avenue
Spanish Lakes Fairways
Fort Pierce, Florida
ITEM TESTED Compacted Foundation Fill -
TEST LOCATION DEPTH * PEN DRY MAX. DRY PERCENT
OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION
I. S.E. 0"- 12" 48 108.1 110.9 97.5 -
2. S.11V. 45 106.7 96.2
3, Center 45 105.9 95.5
4. N.E. 47 107.9 97.3
5. N.W. 46 107.1 96.6
Soil Description:
Brown Sand with 112,01 t I I I I
Traces of Clay W I I I I I 1
In Place Moisture:
9.4 Percent I 111.0 — — 1_.._.j._,. ..�..�...t.,_...
G I I I I I I Optimum Moisture:
12.0 Percent T 1 t I I I
110.0 a--..—.�_..�: _.,r 1._.. ..._...
Max. Dry Density: p I 1 1 1 1 I
110.9 P.C.F.
@ Test Locations The C 109.0 I- — {— — j — —j•— —I j .._.._
Density& Penetrometer FI I I I t
Readings Indicate the t I I I
Degree of Compaction Meets 108.0 L•,_.I_,..^.L_.._I_�....i,.__. ^...
I1qj�+Intl�rr,F �quired D I I 1 I I I
.•�, r' �idatian. ft
`4_*'fir,.�gl #%. k n to Natural Grade. Y 107.0 (— - 'a— —!• 1 — ,
,l's pectf filly. d: 9 10 11 �I� 13� 4�
ED
o. 883
Moisture- o of Dry Weight
rEMer,; DEC 2 7 2017
Permitting Department
r f3i. Lucie County Building Department
,, St. Lucie Count FL
�'� Nd4d spanishlakes.com y
Ronald G.Keller,RE.:372931 SI Lic.No,:860 / Julie E.Keller,P.E.:66366
I
Z2/27/2017 11:26 7725696469 K5M ENGINEERING
• PAGE 01/01
tr a 1 Ar
KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC.
MARTIN V72)337-7755 P.O. Spy(78-1377 SEBASTIAN FL 32978-1377 SEBASTIAN(772)580-0712
PALM BEACH(561)845-7445 www.ksmengineering.net MELBOURNE(321)768-8488
FAX(561)645-8876 E-Mail: KSM@KSMENGINEERING.NEr ST• LUCIE(772)229-9093
C-A.:5693 FAX(772)589-6409
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 2922
Revised December 18, 2017
DATE,TESTED December 12, 2017 KSM JOB#: 173737-•1d/SH/cv
PERMIT## 1710-0111
CONTRACTOR ; Wynne Development
JOB LOCATION 14400 Dalia Avenue
Spanish Lakes Fairways
Fort Pierce, Florida
ITEM TESTED Compacted Foundation Fill
TEST LOCATION DEPTH * PEN DRY MAX- DRY PERCENT
OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION
1. S-W. 0"- 12" 38 105.9 109.3 96.9
2. N.W. 9137 105.3 It95.3
3. Center 39 106.9 IV97.8
4. N.E. 39 107A 98.3
5. S.E. 30 1.05.7 96.7
Soil Description:
Brown Sand 110.0
W I I I t {
In Place Moisture: >: I
10.3 Percent I I I I I I I
G 109.0
Optimum Moisture: H
11.0 Percent T I 1 I I
Max, Dry Density: P 108.0 ; 4-- , r_._i•_-.;.. f .._..
109.3 P.C.F.
C I I I f I I
@ Test Locations The I I I I I
Density& Penetrometer F
Readings Indicate the 107.0
Degree of Compaction Meets
I io►11"4 red ion. R I I I I I I
�,••' r dF�t
Tien to Natural Grade. 106.0 -- i� -- ! — ^4 _.. �.-_.•� .
spe itd:
8 9 10 11 12 13 14
: t
Moisture, /o1"E
. D
It
liT
•��"'.,� �i + * F�~Lucie County Building Department
DEC272017
t i� lihq is spapishlakes.com PermittingDepartment
p ent
Ronald G. Keller,PE.:37293/SI Lic. No.:660 / Julie E.Kell
t� Cie County, FL