HomeMy WebLinkAboutInspection Docs i Planning&Development Services � ( l Building&Code Regulation Division 2300 Virginia Ave,Rm 201 • • Fort Pierce,FL 34982 RECEIVED Phone:772-462-2165 Fax:772-462-6443 SEP .2 2018 BLOWER DOOR TEST FORM Permitting Department House Infiltration Test Certification St. Lucie Countv Prescriptive and Performance Method Date: 2e I.' Permit#: S L o n 28 2 Contractor: W Q_V`z1 M Job Address: `f `f- 1 S 64 I r a A Construction: New Construction—Complete ( ) Existing—After Addition House Infiltration Test_Results SLC Climate Zone 2 f CFM(50)= f 4-5--( Test Date: Volume= 1-5 -8 ACH(50)=CFM(50)x 60/Volume= .5-5 Mechanical Ventilation required less than 3 ACH Passing results must be&ACH(50)or less 1>40ass ( ) Fail FBC,Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f),(g)or(i)or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC,Residential Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w.c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole-house mechanical ventilation in accordance with Section M1507.3: Testina Comi)anv Company Name: Pro-Duct Services Address: 1915 Rio Vista Dr., Ft Pierce 34949 I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Se tion 402.4.1.2 Climate Zone 2. Signature: Printed Name: Martin Klein License/Certification#: 5061633 _ I BUILDING PERFORMANCE INSTITUTE, INC. 107 Hermes Road,Suite 210 ;` Malta, NY 12020 (877)274-1274 www.bpi.org - Martin Klein BPI } BPI ID#:5061633 (SEE REVERSE SIDE FOR DESIGNATIONS AND EXPIRATION DATES) CERTIFIED PROFESSIONAL DESIGNATION EXPIRATION DATE Infiltmdon&Duct leakage(IDL) 4/26/2021 BUILDING PERFORMANCE INSTITUTE, INC. I ' RECEIVED Planning &Development Services Building &Code Regulation Division SEP 19 2300 Virginia Ave 7n1A • - f D - Fort Pierce, FL 34982 Permitting De ' 772-462-2172 Fax 772-462-6443 St juCie C04MP4artr r: CERTIFICATE OF TERMITE TREATMENT CONSTRUCTION SOIL TREATMENT PERMIT #: 1709-0282 JOB ADDRESS: 14415 DALIA FORT PIERCE,FL 34951-2811 BUILDER/CONTRACTOR: WYNNE DEVELOPMENT PEST CONTROL CONTRACTOR: EVICT-A-BUG TERMITE&PEST CONTROL INC. PEST CONTROL LICENSE #:JB175775 We,the undersigned, hereby certify that we have pretreated the above described construction for subterranean termites in accordance with the standards of the National Pest Control Association. Square feet if area treated: 200 LF Chemicals used: DOMINION 2L Percentage of solution: -05% Total gallons used: 100 • 04-24-2018 • 1.30 Date of Treatment. Time of Treatment. Footing Slab 1st Treatment 1st Treatment Re-Treat Re-Treat Driveway Pools 1�Treatment 1st Treatment Re-Treat Re-Treat Other xxxxx Perimeter fo al Inspection 1st Treatment Re-Treat 9-18-2018 Signature of Exterminator Date Note: There must be a completed form for each required beabnent or re-beabnent and this form must be on the job site to be picked up by the inspector at time of each inspection.or Me scheduled inspection will fail and a re inspection fee charged. FBC104.2.6 Certificate of Protective Treatment for prevention of termites A weather resislantjobsite posting board shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed, providing a copy for the person the permit is issued to and another copy for the building permit files The Treatment Certificate shall provide the product used,identity of the applicator, time and date of the treabnent,site location,area treated,chemical used,percent concentration and number of gallons used, to establish a verifiable record of protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall be completed prior to final building approval. St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel box cover, listing all the treatments and dates of applications. Revised 7/24/2014 � p1��7q. S:evpl? noir'�t- ervice 4110 do r '' ocle' ti �iv�sia�ltt P Z x: t? l St 4 F+�r.�'PWe * Ft 82 a����en', . - paxT724Z � 4 .172-462-' - 6 R-equ'estfor 30-DayTemp my Power'Rdease Date: `6� ��� Peril_INftber. Nn( Y\--C h % Project Adder: � �-�� Q�G THE UNDERSIGNED HEREBY REQUEST RELEASE of ELEC[RICAL POWER TO THE ABOVE DESCRIBEDPROPERTy, FOR A PLOD NOT'T4 EX EW THIRTY.(30) DAYS,FOR THE PURPOSE OF TESMG SYSTEMS AND EQUIPMENT IN PREPARATION FOR,A PIMA L.INSPEMON. IN WNSIDtRATION OF APPROVAL OF THE REQU9ST wE•HEIR`ACKl11OV6 umtjE ANb AGREE A FdLIoWS: 1. This temwrary power release is ro4pesWd for the above staled purpose only,and there will he m Occupancy of any tVM ether than that perMitted by consixuction during this time period. 2. As witness by.our signattit 5,we heretiy-agree th abide by all terms and conditions of this agreement, including Building Division Policy,which is incorporated herein by reference. 3. All conditions'and t uiremen listW in Vie attached document erMed"Requirements for 30 ley Power WTesiyAV hW been fulfilled•arid the prreml5e is ready for compliance inspection. 4. All requests for ars ext anion beyond 30 days.must be:made in wnUn,g t D the Building'OfFKial sating the reason fnr the request. Power maybe mmoved•from the site and[or ar Stop Wor K Order issued if the Final'Inspedion has not been approved within 30"days. A tee of$100.00 will be required to EiFt the Stop Work Order. WE HMZFE1!RELEASE AND AGREETO HOLD HARMLESS,ST. WaE COUNTY,AND THEIR EMPLOYEES FROM ALL LI 4BILITIES ANQ.aims&ANY TY E:00 NATURE 1EVKCH MAY AMSE NOW OR IN THE FUTURE OUT OF`THIS TRANSACTION,Ii11t [:UI ItV AN'Y DAMAGE.WHICfi:MAY BE INCURRED.DUE- O THE D ON IECi"fON ELECTRI IL Pp11lYE#t IN THE Eti EW OF VIO[.A17ON OF THIS AGREEMENT: OWNER'SIGNATURE • DA7E GEN NTRAC= N DATE i F.I.EC{RzcAL CoRmcroR SIGNATURE DATE ££6-1 £000/LOOOd 08-1 999L8L83LL £9=£L K,12-80 it ' RECEIVED JUL 10 7018 .Professional Insulators of South Florida Permitting Department FTC Insulation Installation Certificate St.Jude qIr!l3ty St Lucie Count3i Date: June 25,2018 Re:. Lot/Block: Address: 14415 Dalla Project: The undersigned hereby certifies that insulation has been installed in the above described property as follows: 1. Exterior CBS walls have been insulated with: Spray-on Cellulose Thickness in inches: lFiberglass Blankets Manufacturer: Fi Foil Rock Wool Blankets Density: X Aluminum Foil R Value: R 4.1 Rigid Board Polystyrene Other 2. Ceilings(level)have been insulated with: Spray-on Cellulose Thickness in inches: 11.1" X Fiberglass Blown Manufacturer: Climatepro- Rock Wool Blankets Density: Aluminum Foil R-Value: R-30 I jPolyurethane O en Cell SPF Ceilings(Inaccessible)insulated with: Spray-on Cellulose . Thickness in inches: 9.5" X Fiberglass Blankets Manufacturer: Johns Manville Ignition Barrier Density: Fiberglass Blown R-Value: R-30 Cellulose Loose Fill Open Cell SPF 3. Interior kneewalis have been insulated with: Fiberglass Blankets Thickness in inches: Fiberglass Loose Fill Manufacturer: Rock Wool Density: Fiberglass Blo R-Value: Cellulose Open Ce 4. Garage partition walls of A/C living area have X Fi a been insulated with: Rock of Thickness in inches: 3.511 Polyur Manufacturer: Johns Manville Spray-on o Density: Open Cell SP . R Value: R-11 5. The following have been insulated: io WYNNE BUILDING CORP. A s General Contract/Builder !� a :i :9603 CBC1254041 %r,�•;• :3Competency# �'b.` r*� .r.•Vi<!{��.ems. �`�► ' Professional Insulators of South Florida,Inc. Insulation Contractor By: AW By: • I Planning &Development Services Building &Code Regulation Division ® 2300 Virginia Ave • o Fort Pierce, FL 34982 772-462-2172 Fax 772-462-6443 CERTIFICATE OF TERMITE TREATMENT CONSTRUCTION SOIL TREATMENT PERMIT #: i Z JOB ADDRESS: l' v 3 n5t BUILDER/CONTRACTOR: j e PEST CONTROL CONTRACTOR: EVI -A-BUG TERMITE&PEST CONTROL INC. PEST CONTROL LICENSE #: JB175775 We, the undersigned, hereby certify that we have pretreated the above described construction for subterranean termites in accordance with the standards of the National Pest Control Association. Square feet if area treated: n) Chemicals used: DOMINION 2L Percentage of solution: .05% Total gallons used: I Date of Treatment: MZ%6� Time of Treatment: 30 Footing Slab 1st Treatment 1st Treatment Re-Treat Re-Treat Driveway Pools Y' 1st Treatment 1st Treatment Re-Treat Re-Treat _Other ,a ro Perimeter for Final Inspection 1st Treatment Re-Treat '-'siSig ture of Exterminator Da e Note; There must be a completed form for each required treatment or re-treatment and this form must be on the job site to be picked up by the inspector at time of each inspection or the scheduled inspection will fail and a re-inspection fee charged. FBC104.2.6 Certificate of Protective Treatment for prevention of termites A weather resistant jobsite posting board shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed, providing a copy for the person the permit is issued to and another copy for the building permit files The Treatment Certificate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area treated, chemical used,percent concentration and number of gallons used, to establish a verifiable record of protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall be completed prior to final building approval. St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel box cover, listing all the treatments and dates of applications. Revised 7/24/2014 Planning &Development Services Building &Code Regulation Division ® 2300 Virginia Ave Fort Pierce,, FL 34982 772-462-2172 Fax 772-462-6443 CERTIFICATE OF TERMITE TREATMENT CONSTRUCTION SOIL TREATMENT "/��� PERMIT #: D 2-$,2` JOB ADDRESS: Pat ),=� BUILDER/CONTRACTOR: PEST CONTROL CONTRACTOR: EVICT-A-BUG TERMITE&PEST CONTROL INC. PEST CONTROL LICENSE #: JB175775 We, the undersigned, hereby certify that we have pretreated the above described construction for subterranean termites in accordance with the standards of the National Pest Control Association. Square feet if area treated: Sri'g s/1- Chemicals used: DOMINION 2L Percentage of solution: .05% Total gallons used: �19 5 Date of Treatment: / g Time of Treatment: . q /--� FootingSla 11t Treatment _Ist Treatment Re-Treat Re-Treat Driveway Pools 1st Treatment 1st Treatment Re-Treat Re-Treat Other Perimeter for Final ection 1st Treatment Re-Treat Signature of Exterminat Date Note. There must be a completed form for each required treatment or re-treatment and this form must be on the job site to be picked up by the inspector at time of each Inspection or the scheduled Inspection will fail and a re Inspection fee charged. FBC104.2.6 Certificate of Protective Treatment for prevention of termites A weather resistantjobsite posting board shall be provided to receive duplicate Treatment Certlflcates as each required protective treatment Is completed, providing a copy for the person the permit Is issued to and another copy for the bullding permit files Tire Treatment Certificate shall provide the product used,Identity of the applicator, time and date of the treatment,site locatlon, area treated, chemical used,percent concentration and number of gallons used, to establish a verifiable record of protective treatment. If the soil chemical barrier method for termite prevention Is used, final exterior treatment shall be completed prior to final bullding approval. St(Lucie County requires for the final inspection for CO.. a Permanent Sticker to be placed on' the electrical panel box cover, listing all the treatments and dates of applications. Revised 7/24/2014 ' • i i IL 9 AVjL LLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772)337-7755 P.O. BOX 78-1377 SEBASTIAN FL 32978-1377 SEBASTIAN (772)589-0712 PALM BEACH (561)845-7445 www.ksmengineering.net MELBOURNE(321)768-8488 FAX(561)845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE(772)229-9093 C.A.:5693 FAX(772)589-6469 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 DATE TESTED December 22, 2017 KSM JOB# : 173863-1 d/SF/cv PERMIT# 1709-0282 CONTRACTOR Wynne Development JOB LOCATION 14415 Dalia Avenue Spanish Lakes Fairways Fort Pierce, Florida ITEM TESTED Compacted Foundation Fill TEST LOCATION DEPTH * PEN DRY MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1. S.E. 0" - 12" 48 108.1 110.9 97.5 2. S.W. 45 106.7 if96.2 3. Center 45 105.9 it 95.5 4. N.E. 47 107.9 It97.3 5. N.W. 46 107.1 96.6 Soil Description: Brown Sand with 112.0 I I I I 1 Traces of Clay W I I I I I I In Place Moisture: E I I I I I I 9.4 Percent I 111.0 ..—.._ G I I I I I I Optimum Moisture: H 12.0 Percent T I I I I I 110.0 —.._.1_.._.' _.._I._.. _.. .._.._ Max. Dry Density: P I I I I I I 110.9 P.C.F. I I I I I I C 109.0 @ Test Locations The I—.._.j_ ._.�._.._f._..�.. ..—.._ Density & Penetrometer F I I I I I Readings Indicate the I I I I Degree of Compaction Meets 108.0 •I•— — Minimum Required D I I I I I 115111 6�agation. R Iti e en to Natural Grade. Y 107.09 1 15 No. Mei2ule e6ller P V F 'den : , ; Department `.`�ucie County Building Department COuntYrFL � 6 anlshlakes.com �,�181888161Its%% Ronald G. Keller, P.E.: 37293/SI Lic. No.: 860 ! Julie E. Keller, P.E.: 68366 12/27/2017 16:03 7725896469 KSM ENGINEERING PAGE 01/01 I Walks . J&1JAW KELLER, SCHLEICHER & MacWILL1AM ENGINEERING AND TESTING, INC. MARTIN(772)337-7755 RO, BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN(772)589-0712 PALM BEACH(661)845-7445 www.ksmengineering.nat MELBOURNE(321)768-8488 FAX(561)845-8876 E-Mail_KSM@KSMENGINEERING.NET ST• LUCIE(772)229-90� C-A.:5693 FAX(772)589-64i 9 SOIL COMPACTION REPORT � ASTM D 1567 and ASTM D 2922 DATE TESTED : December 22, 2017 KSM JOB#: 173863-1d1SFlcv PERMIT# 1709-0282 CONTRACTOR Wynne Development JOB LOCATION 14415 Dalia Avenue Spanish Lakes Fairways Fort Pierce, Florida ITEM TESTED Compacted Foundation Fill - TEST LOCATION DEPTH * PEN DRY MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION I. S.E. 0"- 12" 48 108.1 110.9 97.5 - 2. S.11V. 45 106.7 96.2 3, Center 45 105.9 95.5 4. N.E. 47 107.9 97.3 5. N.W. 46 107.1 96.6 Soil Description: Brown Sand with 112,01 t I I I I Traces of Clay W I I I I I 1 In Place Moisture: 9.4 Percent I 111.0 — — 1_.._.j._,. ..�..�...t.,_... G I I I I I I Optimum Moisture: 12.0 Percent T 1 t I I I 110.0 a--..—.�_..�: _.,r 1._.. ..._... Max. Dry Density: p I 1 1 1 1 I 110.9 P.C.F. @ Test Locations The C 109.0 I- — {— — j — —j•— —I j .._.._ Density& Penetrometer FI I I I t Readings Indicate the t I I I Degree of Compaction Meets 108.0 L•,_.I_,..^.L_.._I_�....i,.__. ^... I1qj�+Intl�rr,F �quired D I I 1 I I I .•�, r' �idatian. ft `4_*'fir,.�gl #%. k n to Natural Grade. Y 107.0 (— - 'a— —!• 1 — , ,l's pectf filly. d: 9 10 11 �I� 13� 4� ED o. 883 Moisture- o of Dry Weight rEMer,; DEC 2 7 2017 Permitting Department r f3i. Lucie County Building Department ,, St. Lucie Count FL �'� Nd4d spanishlakes.com y Ronald G.Keller,RE.:372931 SI Lic.No,:860 / Julie E.Keller,P.E.:66366 I Z2/27/2017 11:26 7725696469 K5M ENGINEERING • PAGE 01/01 tr a 1 Ar KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN V72)337-7755 P.O. Spy(78-1377 SEBASTIAN FL 32978-1377 SEBASTIAN(772)580-0712 PALM BEACH(561)845-7445 www.ksmengineering.net MELBOURNE(321)768-8488 FAX(561)645-8876 E-Mail: KSM@KSMENGINEERING.NEr ST• LUCIE(772)229-9093 C-A.:5693 FAX(772)589-6409 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 Revised December 18, 2017 DATE,TESTED December 12, 2017 KSM JOB#: 173737-•1d/SH/cv PERMIT## 1710-0111 CONTRACTOR ; Wynne Development JOB LOCATION 14400 Dalia Avenue Spanish Lakes Fairways Fort Pierce, Florida ITEM TESTED Compacted Foundation Fill TEST LOCATION DEPTH * PEN DRY MAX- DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1. S-W. 0"- 12" 38 105.9 109.3 96.9 2. N.W. 9137 105.3 It95.3 3. Center 39 106.9 IV97.8 4. N.E. 39 107A 98.3 5. S.E. 30 1.05.7 96.7 Soil Description: Brown Sand 110.0 W I I I t { In Place Moisture: >: I 10.3 Percent I I I I I I I G 109.0 Optimum Moisture: H 11.0 Percent T I 1 I I Max, Dry Density: P 108.0 ; 4-- , r_._i•_-.;.. f .._.. 109.3 P.C.F. C I I I f I I @ Test Locations The I I I I I Density& Penetrometer F Readings Indicate the 107.0 Degree of Compaction Meets I io►11"4 red ion. R I I I I I I �,••' r dF�t Tien to Natural Grade. 106.0 -- i� -- ! — ^4 _.. �.-_.•� . spe itd: 8 9 10 11 12 13 14 : t Moisture, /o1"E . D It liT •��"'.,� �i + * F�~Lucie County Building Department DEC272017 t i� lihq is spapishlakes.com PermittingDepartment p ent Ronald G. Keller,PE.:37293/SI Lic. No.:660 / Julie E.Kell t� Cie County, FL