FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
`Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT
Sheet: WYNNE DEVELOPMENT Permit Office: ST.LUCIE COUNTY
City,State,Zip: F PIERCE, F Permit Number:
Owner: ,� � CACA\N_C� Jurisdiction:
Design Location: FL,ST_LUCIE_CO_INTL County:: ST.LUCIE COUNTY(Florida Climate Zone 2)
i
1. New construction or existing New(From Plans) 9. Wall Types(1437.3 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1250.00 ftz
b.Frame-Wood,Exterior R=11.0 187.33 ftz
3. Number of units,if multiple family 1 c. N/A R= ftZ
4. Number of Bedrooms 2 d.N/A R= ftz
5. Is this a worst case? Yes 10.Ceiling Types (1446.0 sqft.) Insulation Area z
a.Under Attic(Vented) R=30.0 1446.00 ft
6. Conditioned floor area above grade(ftz) 1446 b.N/A R= ft2
Conditioned floor area below grade(ftz) 0 c.N/A R= ftz
11. Ducts R ftz
7. Windows(139.2 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 320
al. U-Factor: Dbl, U=0.54 99.23 ftz
i SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.25 a.Central Unit 34.8 SEER:15.00
c. U-Factor: N/A ftz
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ftz a.Electric Heat Pump 34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.586 ft.
Area Weighted Average SHGC: 0.250 14.Hot water systems
8. Floor Types (1446.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF:0.970
a.Slab-On-Grade Edge Insulation R=0.0 1446.00 ftz b. Conservation features
b.N/A R= ftz None
c.N/A R= ftz 15.Credits Pstat
Total Proposed Modified Loads: 46.91
Glass/Floor Area: 0.096 PASS
Total Baseline Loads: 48.19
I hereby certify that the plans and specifications covered by Review of the plans and O�-V$E STATt�
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code. ti rrrrrr '�%. • �� `O
PREPARED Y: Before construction is completed r
DATE: this building will be inspected for
compliance with Section 553.908 * °
I hereby certify that this building,as designed, is in compliance Florida Statutes.
with the Florida Energy Code. G'OD WE
i
OWNER/A BUILDING OFFICIAL:
DATE: DATE:
I
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
6%16/2017 11:49 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
i
i
F0RAR405-2014
r PROJECT
THE GRAND CARLTON Bedrooms: 2 Address Type: Street Address
Building Type: User Conditioned Area: 1446 Lot#
Owner: Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 135 Street: WYNNE DEVELOPME
Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: ST.LUCIE COUNTY
Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
IECC Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,ST_LUCIE_CO_INTL FL VERO_BEACH_MUNI 2 39 90 70 75 299 58 Medium
BLOCKS
Number Name Area Volume
I
11 Entire House 1446 11568
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1I BEDROOM 234 1872 No 2 1 1 Yes Yes Yes
2 WIC 54 432 No 0 1 No Yes Yes
3 MASTER BATH 63 504 No 0 1 Yes Yes Yes
4 M.BATH 56 448 No 0 1 Yes Yes Yes
F
5 KITCHEN 172 1376 Yes 0 1 No Yes Yes
I
6 BATH 45 360 No 0 1 Yes Yes Yes
7, BEDROOM 2 204 1632 No 1 1 1 Yes Yes Yes
8, LAUNDRY 42 336 No 0 1 Yes Yes Yes
9'I
GREAT/DINING 526 4208 No 0 1 Yes Yes Yes
110 FOYER 50 400 No 0 1 Yes Yes Yes
FLOORS
vi # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio BEDROOM 40 ft 0 234 ft2 ---- 0 1 0
I
2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 54 ft2 ---- 0 1 0
3 Slab-On-Grade Edge Insulatio MASTER BATH 9 ft 0 63 ft2 ---- 0 1 0
i
i
4SIab-On-Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 ---- 0 1 0
I
5 Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 172 ft2 ---- 0 1 0
i
6 Slab-On-Grade Edge Insulatio BATH 5 ft 0 45 ft2 ---- 0 1 0
7 Slab-On-Grade Edge Insulatio BEDROOM 2 34.2 ft 0 204 ft2 ---- 0 1 0
6/16/2017 11:49 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405 2014
FLOORS
F' 8
Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
lab-On-Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ____ 0 1 0
9 Slab-On-Grade Edge Insulatio GREAT/DINING 47 ft 0 526 ft2 0 1 0
10SIab-On-Grade Edge Insulatio FOYER 7 ft 0 50 ft2 ---- 0 1 0
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V� # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
i
1 Gable or shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 0 18.4
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 1446 ft2 N N
i
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type,
1 Under Attic(Vented) BEDROOM 30 Blown 234 ft2 0.1 Wood
2 Under Attic(Vented) WIC 30 Blown 54 ft2 0.1 Wood
3 Under Attic(Vented) MASTER BATH 30 Blown 63 ft2 0.1 Wood
I
4 Under Attic(Vented) M. BATH 30 Blown 56 ft2 0.1 Wood
5 Under Attic(Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood
6 Under Attic(Vented) BATH 30 Blown 45 ft2 0.1 Wood
7 Under Attic(Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood
8 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood
9 Under Attic(Vented) GREAT/DINING 30 Blown 526 ft2 0.1 Wood
10 Under Attic(Vented) FOYER 30 Blown 50 ft2 0.1 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w
1 N=>SE Exterior Concrete Block-Ext Insd9EDR0OM 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0
2 S=>NW Exterior Concrete Block-Ext InsEEDROOM 4.1 18 0 8 0 144.0 ft2 0 0 0.5 0
3 W=>NE Exterior Concrete Block-Ext InsdHEDROOM 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0
4 S=>NW Exterior Concrete Block-Ext IngdASTER BA 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0
5 S=>NW Exterior Concrete Block-Ext InsuM.BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0
i
6 N=>SE Exterior Concrete Block-Ext Insul.BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0
7 N=>SE Exterior Concrete Block-Ext ImMDR00M 2 4.1 16 0. 8 0 128.0 ft2 0 0 0.5 0
8 E=>SW Exterior Concrete Block-Ext In0EDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.5 0
9 SE=>W Exterior Concrete Block-Ext In,43ffDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.5 0
10 S=>NW Exterior Concrete Block-Ext In0EDROOM 2 4.1 4 0 8 0 32.0 ft2 0 0 0.5 0
11 S=>NW Exterior Concrete Block-Ext InsillAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0
12 N=>SE Exterior Concrete Block-Ext InsGREAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.5 0
6/1/2017 8:43 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405'2014
� WALLS
Adjacent Space Cavity Width Height Sheathing Framing. Solar Below Ornt 10 Well Type
13 W=>NE Exterior Concrete Block-Ext InsGREAT/DINT 4.1 21 0 8 0 168.0 ft2 0 0 0.5 0
14 N=>SE Exterior Concrete Block-Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0
15 E=>SW Exterior Concrete Block-Ext Insul FOYER 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0
16 N=>SE Exterior Frame-Wood GREAT/DIN[ 11 23 5 8 187.3 ft2 0.23 0.5 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 E=>SW Insulated FOYER None .28 3 6 8 20 ft2
I
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
j Wall Overhang
Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 W=>NE 3 Metal Low-E Double Yes 0.54 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5
2 S=>NW 5 Metal Low-E Double Yes 0.54 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in None None
3 E=>SW 8 Metal Low-E Double Yes 0.54 0.25 23.2 ft2 1 ft 0 in 1 ft 4 in None None
4 N=>SE 12 Metal Low-E Double Yes 0.54 0.25 36.8 ft2 1 ft 0 in 1 ft 4 in None None
5 W=>NE 13 Metal Low-E Double Yes 0.55 0.25 40.0 ft2 10 ft 0 in 1 ft 4 in None None
I
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 315ft2 315ft2 24ft 8ft 11
i
i
INFILTRATION
I
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) 000356 1349.6 74.09 139.34 .2455 7
BEATING SYSTEM
# System Type Subtype Efficiency Capacity. Block Ducts
1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1
!
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1
I
f
i
I
i
6/1/2017 8:43 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
i
FORM R405'2014
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
—Supply— —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 320 ftz Attic 80 ftz Default Leakage Attic (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Conlin [[ ]]Jan [[ ]Feb Mar Apr May X Jun n
Jul il
Au ri
Se [ ]Oct Nov H
Dec
He [X]Jan [X]Feb Mar f Apr f May Jun Jul Au Sep [ ]Oct Nov Dec
Ventin [[ ]]Jan [[ ]]Feb [X Mar [X]Apr [ May Jun Jul Aug Se [X]Oct HX Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78.
PM 78 78 78 78 78 78 78 78 78 78 78 78
I
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
. PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68, 68 68 68 68 68 66 66
i
i
i
�I
i
i
6/1/2017 8:43 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
I
b
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT
Street: WYNNE DEVELOPMENT Permit Office: ST.LUCIE COUNTY
City,State,Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL,ST_LUCIE_CO_INTL
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings,drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
j Knee walls shall be sealed.
Windows, skylights and doors The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawispace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated,and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls,or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
6/16/2017 11:54 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
I
FORM.R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DMPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
WYNNE DEVELOPMENT, FT. PIERCE, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
a.Concrete Block-Ext Insul,Exterior R=4.1 1250.00 ft2
2. Single family or multiple family Single-family b. Frame-Wood, Exterior R=11.0 187.33 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 2 d.NIA R= ft2
10.Ceiling Types Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1446.00 ft2
6. Conditioned floor area(ft2) 1446 b.N/A R= ft2
c.N/A R= ft2
7. Windows" Description Area R ft2
a.,U-Factor: Dbl, U=0.54 99.23 ft2 11.Ducts
a.Sup:Attic, Ret:.Attic,AH:Attic 6 320
j SHGC: SHGC=0.25
b.,U-Factor: Dbl,U=0.55 40.00 ft2
SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency
c.:U-Factor: N/A ft2 a.Central Unit 34.8 SEER:15.00
i SHGC:
d.,U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 34.8 HSPF:8.50
Area Weighted Average Overhang Depth: 3.586 ft.
Area Weighted Average SHGC: 0.250
8. Floor Types Insulation Area 14.Hot water systems Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1446.00 ft2 a.Electric
EF:0.97
b.N/A R= ft2 b. Conservation features
c.N/A R= ft2 None
15.Credits Pstat
I certify That this home has complied with the Florida Energy Efficiency Code for Building TgIE STA��
Construction through the above energy saving features which will be installed (or exceeded) y a
in this home before final inspection. Otherwise, a new EPL Display Card will be completed ,,,;'''
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home: � Ck City/FL Zip: ;eC� , c
oD w6
Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/1/2017 8:43 AM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
+"Wrightsoft® Project Summary patEntlrre House. By:
QUICK CALCS, INC.
',317 sT.Luc IE LN.,FT.PIERCE,FL 34946 Phone;.772-166-6799 Fax 772-466A6796. Email:QUICKCALCS@A0L.COM,
Project
Information
For: THE GRAND CARLTON
WYNNE DEVELOPMENT, FT. PIERCE, FL
� \ C_%
Notes:
i
i
Design • •
i
Weather -Fort Pierce, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 42 OF Outside db ; 90 OF
Inside db. 70 OF Inside.db 75 OF
Design,TD 28 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 61 gr/lb
I Heating Summary Sensible Cooling-Equipment Load Sizing
Structure 17848 Btuh Structure 17520 -Btuh
Ducts 5654 Btuh Ducts 8536 Btuh
Central vent(0 cfm): 0 Btuh Central vent(0 cfm) 0: Btuh
Humidification 0 .Btuh Blower(none) 0 Btuh
Piping 0 Btuh
Equipment load 23503 Btuh Use manufacturer's data n
Rate/swing multiplier 0.95
Infiltration Equipment sensible load .24753 Btuh
i
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 3203 Btuh
Ducts 2318 Btuh
j Central vent(0 cfm) 0 Btuh
Heat" Cooling (none)
Area(W) 1446 .1446 Equipment latent load 5521 Btuh
Volume(ft3) 12511 125.11
Air changes/hour 0.45 0.23 Equipment total load 30274 Btuh
Equiv.AVF(cfm) 94 48 Req. total capacity at 0.70 SHR 2.9 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING
Model. 25HBC536A*030 Cond 25HBC536A*030
AHRI ref 7914585 Coil FX4DN(B;F)037
AHRI ref 7914585
i Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER
Heating input Sensible-cooling 24360 Btuh
Heating output 34600 ,Btuh @ 47OF Latent cooling 10440- Btuh
Temperature rise 27. OF Total cooling 34800 Btuh
I Actual air flow 1160 cfm Actual air flow 1160 cfm
Air flow factor 0.049 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0.50 in H2O Static pressure -0.50 in H2O
Space thermostat Load sensible heat ratio 0.83
Capacity balance point=32 OF
Backup:
Input=7 kW, Output=23009 Btuh, 100 AFUE
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
QL wrightsoft` 2017-Apr-11 09:29:38� Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1
...uick Calcs\Documents%THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N
i
i
i
A
-jai wrigntsok Right-M Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By:
317 ST LUCIE LN.,FT.PIERCE,FL 34946 Phone:772466-6799 Fax 772-466-6796 Email:QUICKCALCS a1 OL.COM
1 Room name Entire.House BEDROOM
2 Evosed wall 156.2 ft 49.0 ft
3. Room height 8.7 ft d 8.0 ft heat/cool
4 Room dimensions 1.0 x 297.0 ft
5 Room area 1445.5 ft' 297.0 ft'
Ty Construction U-value Or HTM Area
number (Btuh/fV °F) (Btuh/ft2) or perimeter (ft) (Btuh) oorperimeter (ft) (Btuh) .
Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool
6 0143 n` 4-.W 2:55 503 465 9862 1184 72 72. 288 183
4A5 tom 0370. n:. 21:56 19:31. 38 0 815 , 730. .` 0' - : . -0 0 0
13A4ocs 0.143 a 4.00 2.55 128 83 333 212 0 0 0 0
1A-c1om 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0
11 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0
W. '.13A-4bcs 0.143 se 4.00 255 34 34 136 86 0 0 :0 0
1Q! 13A-4ocs 0.143 s 4.00 255 360 353 1414 899 216 216 865 550
-a 1Aclom 1.270 s 35.56 34.77 7 7 247 241 0 0 0 0
13446cs 0.143 w' 4.00 255 310 .237 949 603 104. .72 288 183'
1.A clom ;, 1.270 w 35;56 i Z5.91 w -32' 2 - 1140 1770 32 2. 1740 17Z0.
4A52om ; :0 770 -w 21.56 19.31 41 41 880:,:`. 788_= 0:: Q
.P 12C-0sw 0.091 . -. - 2.55 1.28 192 192 _ . 489 246 0 0 0 0
C 16A 30md' 0.032. 0 90 ; 232 1446 : 1446 1295 m: 297. 297 : .:: 286 689
F. 22A-tpl 0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 0
6 c)AED excursion 918 627
Envelope loss/gain 14961 13349 4204 4003
,12 a) Infiltration 2867 791 848 232
b) Room ventilation 0 0 0 0
13 Intemal gains: Occupants @ 230 6 1380 3 .690
Appliances/other 2000 0
Subtotal(lines 6 to 18) 17848 17520 5053 4925
Less e)demal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 17848 17520 5053 4925
15 Duct loads 32% 49% 5654 8536 32% 49% 1601 2400
Total room load 23503 26056 1 6653 7325
Air required(cfm) 1160 1160 328 326
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-Fk- wrightsoft• 2017-Apr-11 09:29:38
Right-Suite®Universal 2017 17.0.14 RSU08101 Pagel
...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Cale=MJ8 Front Door faces: N
IF Job:
wrightsoft'. Right-J®Worksheet
Entire House Date:
QUICK CALCS, INC. By.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email QUICKCALCS@,AOL.COM
1 Room name WIC KrrCHEN
2 Exposed wall O ft O ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 6.0 x 9.0 ft 1.0 x 1720 ft
5 Room area 54.0 ft2 1720 ft2
Ty Construction U-value Or HTM Area (ft-) Load Area z
number (Btuh/ft�°F). (Btuh/ftz) or perimeter ft (ft) Load
( ) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Grass N/P/S Heat Cool Grass N/P/S Heat Cool
6 W 13A-0ocs:` 0143 rt 4.00 2.55 0 " :. 0 p}: 0.: 0 0 0 0
G 4Ar2om. 0 770 n 21t56 . .1931 _ 0 0 0 0. 0 0 0 0
13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0
-G 1Aclom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0
11 11D0 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0
W. 13A-0ocs 0`143 se. 4.00 2.55 . 0 0 0 . 0 0 p p -p
VI/ 13A-4ocs 0.149 s 4.00 255 0 0 0 0 0 0 0 0
�--G 1Aclom 1270 s 35.56 34.77 0 0 0 0 0 0 0 0
13A46cs. _ 0 143 w- 4.00 2.55 0 0 0 -0 0 0 0 0
I[Xc1om. 1.270 ,.w 35.56 55.21 0 0 p. 0 0 0 0 0,
4A5 2om::. -. ;0.770 .w: 21.56 -. 19.31. .0 0 0 . 0 0 p p 0
P 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 64 64 163 82
C . 76A Omd� ' 0.032 0:90 . 2;32 54 54 48 125 :- 172 ".172 154 399
F 22A-tpl 0.989 - 27.69 0.00 54 0 0 0 172 0 0 0
6 c)AED excursion -9 -170
i Envelope loss/gain 48 117 317 311
12 a) Infiltration 0 0 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 P000
Subtotal Qines 6 to 13) 48 117 317 2311
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 48 117 317 2311 32% 49% 10
15 Duct loads 32% 49% 15 57 0 1126
Total room load 64 174 418 -3437
Air required(cfm) 3 8 21 153
Calculations approved byACCA to meet all requirements of Manual J.8th Ed.
wcightsoft Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 2
...uick CaIcslDocumOnts\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N
F -wrightsoft° Right-J®Worksheet Job:
Entire House Date:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS AOL:COM
1 Room name BATH BEDROOM 2
2 Exposed wall 5.0 ft 34.2 ft
3 Room height 8.0 ft heat/cool. 8.0 ft heat/cool
4 Room dimensions 9.0 x .5.0 ft 1.0 x 203.5 ft
5 Room area 45.0 ft2 203.5 ft'
Ty I Construction U-value. Or HTM Area (ft') Load Area- (ftj Load
number (Btuh/ft'-°F) (Btuh/ft2) 1 or perimeter (ft) (Btuh) or perimeter. (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross I N/P/S Heat Cool
6 13A4acs•: 0143 ns 4E00 2 55 40 40 160,, 102 128: 128 513 `326
::4A52om;: ;.0.770 n. 2156 19.31 0 0 0` 0 ' 0°" 0 0 0
13AAocs 0.143 a 4.00 2.55 0 0 0. 0 80 56 225 143
IA-clom 1.270 a 35.56 87.29 0 0 0 0 24 2 848 2082
11 I--D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0
W :13AAocs 0143. se 4.00 265 0 0 0 0 34 34- 136 86
IIV 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 32 32 128 81
I--G 1Aclom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
13A-00cs .D 143 w 4.00 2.55 -. 0 0 0 .0 0 0 0, 0
1A c1om 1 270 w 35:56 5521 0' 0 0 0 0 -0 0 0
0:.70 ':.W 21:56 . '19:31 0 0 -0 0 0 0 0 , 0
P 12C-0s.w 0. 91.- - 2.55 _ 1.28. 0 0 0 0 ., 0. - 0 0 . 0
C 18A 30ind :__ 0.Q32 __ .:0.90 . :'2.32 :. ...'45 45 40 104, '204` , 204 - +182 � " _ ;472
F 22A tpl 0.989 27.69 0.d6 45 5 138 0 204 34 . 946 0
-85
j 6 c)AED excursion -16
Envelope loss/gain 339 190 2978 3106
12 a)- Infiltration . 87 24 593 162
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 1 230
Appliances/other 0 0
Subtotal pines 6 to 13) 425 214 3571 3498
Less wdemal load 0 0 0 0
Less transfer 0 0 0 0
0 0 0 0
Redistribution
14 Subtotal 425 214 3571 3498
15 Duct loads 32% 49% 135 104 320/o 49% 1131 1704
Total room load 560 318 4702 5203
Air required(cfm) 28 14 232 232
Calculations approved byACCA to meet all requirements of Manual J.8th Ed.
�� wrightsoft- 2017-Apr-11 09: e 3
'�- Right-Suite®Universal.2017 17.0.14 RSU08101 Page 3
...uictc Caics\Documents\THE GRAND CARLTON-1446.rup Cale=MJ8 Front Door faces: N
l
- wrlohtsoft- Right.�-J®Worksheet °b
Entire House Date:
QUICK CALCS, INC. By:
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS AOL.COM
1 Room name LAUNDRY GREAT/DINING
2 Expmed wall 6.0 ft 47.0 ft
3 Room height 8.0 ft heat/cool 9.8 ft heat/cool
4 Room dimensions 7.0 x 6.0 ft 1.0. x. 526.0 ft
5 Room area 42.0 ft2 526.0 f12.
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/ft2-°F) (Btu 2) or perimeter (ft) (Btuh) or
perimeter. (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool
6 , 13A flocs 0:143 n 4 00. 2;55 U 0 -0 0 255- 217; 869 _552
4A5 tom 0:770 n:= 21:56 19.31. 0 0 , 0 : 0 .: 38= "'0.- 815 730
�j 13AAocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0
1 F-G 1Aclom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0
11 I-D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0
W A.ZiAm4ocs 0143 'se -.4.00 2.65 0 0 0 0 0 0 ' 0 0
V�! 13A-4ocs 0.143 s 4.00 2.55 48 48 192 122 0 0 0 0
---G 1A-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
13AA6cs 0.143 w 4.00 2.55 0 0 0 0` 206 165 661 420
1Ac1 om 1.276 w. 35:56. 55.21 0 0 0 0 0: ;0 -.0 0
A;770 w.:: 21.56: 19:31 0. 0:.' 0. . .`: 41 '.- -41 :880 r788'
P 12C-O.sw 0.091. - 2.55 1:28 56 56 143 72 0.- 0 .0 0
C , . 16A 30.md::,; `:.'. '0:032 =._-`- 0,90 2 32 42 :. 42:1. 313' 97 526 526, 4Z1 1220
F 22A-tpl 0.989 - 27.69 0.00 42 6 166 0 526 47 1302 0
W.
6 c)AED excursion =� 668
Envelope loss/gain 539 270 4997 4379
12 a): Infiltration 104 28 997 273
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ MO 0 0 2 460
Appliances/other 0 0
Subtotal(lines 6 to 13) . 643 298 5994 5112
Less extemal load 0 0 0 0
Less.transfer 0 0 0 : 0
Redistribution 0 0 0 0
14 .Subtotal 643 298 5994 5112
15 Duct loads 32% 49% 204 145 32% 49% 1899 2490
Totalroom load 846 443 7892 7602
Air required(cfm) 42 20 3901. 338
Calculations approved byACCA to meet all requirements of Manual J.8th Ed.
- - wrightsoft' 2017-Apr-11 09:29:38
A & Right-Suite®Universal 2017 17.0.14 RSU08101 Page 4
...uick Calcs%Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N
I.
- + wrightsoft Right-JO Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By:
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name FOYER
M.BATH
8.0 ft
3 Room heighted 8.0 ft 7.0 ft heat/cool ft heat/cool
4 Room 5 Room dimensions 1.0 x 50.0 ft 7.0 x 8.0 ft.
area 50.0 ft2 56.0 ft
Ty Construction U-value Or HTM Area (ft2) Load Area
number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh or (ft2) Load
perimeter (ft) (Btuh)
Heat Coal Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A flocs 0143 n�. 4.00 '2 55 8 8 ` 32 20 . 0 0 0 p.
AS2om, 0 770 %n' 21:56 19.31 0 0 0 0 '0:.. 0.; 0 0.
13A-0ocs 0.143 a 4.00 2.55 48 27 108 69 0 0 0 0
1A-c1om 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0
11 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0
W ,13A41ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0
V►/ 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 64 57 228 145
t--G 1Ac1om 1.270 s 35.56 34.77 0 0 0 0 7 7 247 241
13A4ocs 0 143 w 4:00, 2.55 0 0 0 0 0 0 0 0.
IA-c1om 1.270 w ' 3556 55:21 0 0 0 0.- 0 0 ,0 0
4A5 2om:. 0 770 _w'' 21;56 19:31 �0 . 0:. 0'- 0 - 0„ 0.
P 12C-0sw 0.091 - 2.55 1.28 72 72 183 92 0 0 0 0
C `AM-30md.. 0 032 s:_ .: 0.90 2;32 50` 50 45 116 �56;... 56 ., 50 13.0
F 22A tpI 0 989 - 27.69 0.00 50 7 194 0 56 8 222 0
6 c)AED excursion _39 _38
Envelope loss/gain 792 496 747 478
12 a) Infiltration 121 M 138 38
b) 'Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 913 529 885 . 516
Less extemal load 0 0 0 0
Less transfer 0. 0 0 0
Redistribution 0 0 0 0
14 Subtotal 913 529 885 516
15 Duct loads 32% 49% 289 258 32% 49% 280 251
Total room load 1202 787 1166 768
Air required(cfm) 591 35 58 34
Calculations approved byACCA to meet all requirements of Manual.J 8th Ed.
-IF14- wrightsoft- 2017-Apr-11 09:29:38
Right-Suite®Universal 2017 17.0.14 RSU08101 Page 5
...trick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N
- wrightsoft° Duct System Summary Date,
Entire House By:
QUICK CALCS,INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:.772-466-6799 Fax 772-466.6796 Email OUICKCALCWOL.COM
Project I • •
For: THE GRAND CARLTON
WYNNE DEVELOPMENT, FT. PIERCE, FL
Heating. Cooling
External static pressure 0.50 in H2O 0.50 in H2O
Pressure losses 0 in H2O. 0 in H2O
Available static pressure 0.50 -in H2O 0.50 in H2O
Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O
Lowest friction rate 0.285 in/100ft 0.285 in/100ft
Actual air flow 1160 cfm 1160 cfm
Total effective length(TEL) 176 ft
SupplyDetail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name &uh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln (ft) Trunk
BATH h 560 28 14 0.364 4.0 0xO VIFx 22.4 115.0 st1
BEDROOM 2 h 4702 232 232 0.360 7.0 Ox 0 VIFx 23.9 115.0 st1
BEDROOM-A h 3327 164 163- 0.300 6.0 Ox0 VIFx 31.8 135.0 st2
BEDROOM-B h 3327 164 163 0.285 6.0 Ox0 VIFx 40.6 135.0 st2
FOYER h 1202 59 35 0.505 4.0 Ox 0 VIFx 4.0 95.0
GREAVDINING h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8_ 135.0 st2
GREAT/DINING-A h 3946 195 169 0.300 7.0 ox0 VIFx 31.8 135.0 st2
KITCHEN c 3437 21 153 0.379 6.0 ox0 VIFx 17.0 115.0 st1
LAUNDRY h 846 42 20 0.361 4.0 Ox 0 VIFx 23.3 115.0 st1
M.BATH-A h 768 58 34 0 0 Ox 0 VIFx 0 0
wlc c 174 3 8 0.309 4.0 Ox 0 VIFx 27.0 135.0 st2
SupplyDetail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VinlFlx st1
st1 Peak AVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFlx
wlri htsoft° 2017-Apr-1109:29:38
9 RightSuite®Universal 2017 17.0.14 RSU08101 Page 1
'� ...uick Calcs\Documents\THE GRAND CARLTON1446.rup Calc=MJ8 Front Door faces: N
Return Branch Detail Table
Grille Htg Clg . TEL Design VelOc Diam H x W Stud/J6ist Duct
Name Size(in)' . (cfm). (cfm): (ft) FR . (fpm). (in) (in) Opening(in). Matf Trunk
rb1 Ox0 . 1160 1160 0, 0 0 0. Ox 0 VIFx
wri htsofta 2017-Apr-11 09:29:38
9 Right-Suite®Universal 2017 17.0.14 RSU08101
Page 2
ACCA ..uick CalcslDocuments\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N