File copy FOr_-t' R405-2014 F�J�ORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method i Project Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY City State,Zip: FT.PIERCE,FL, Permit Number: Ow er: \cb �A, Jurisdiction: Desll�gn Location: FL,Fort Pierce County:: ST.LUCIE COUNTY(Florida Climate Zone 2) 1. Neconstruction or existing New(From Plans) 9. Wall Types(1432.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1224.00 ft2 b.Frame-Wood,Adjacent R=11.0 208.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10.Ceiling Types (1753.0 sqft.) Insulation Area 5. Is his a worst case? Yes a.Under Attic(Vented) R=30.0 1753.00 ft2 6. Conditioned floor area above grade(ft2) 1753 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 J 11.Ducts R ft2 7. W ndows(151.4 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 325 a. U-Factor: Sgl,U=0.54 111.36 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a.Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.250 14.Hot water systems a.Electric Cap:40 gallons 8. Floor Types (1753.0 sqft.) Insulation Area EF:0.970 a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features b.N/A R= ft2 None C.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 53.74 PASS Total Baseline Loads: 53.87 I hereby certify that the plans and specifications covered by Review of the plans and FJOE SCAT this calculation are in compliance with the Florida Energy specifications covered by this 1+� = O Codl. calculation indicates compliance with the Florida Energy Code. � nru �."�:- .`;•�•'��,��O PREPARE BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 * °_ I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. G'0 OWNER/A T: i BUILDING OFFICIAL: DATE: b V DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 4/3/2017 1:21 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM05-2014 PROJECT Tit WYNNE THE WINDSOR Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot# Owner: Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225 Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: ST.LUCIE COUNTY JurisIdiction: Whole House Fan: No City,State,Zip: FT.PIERCE, Family Type: Single-family FL, New/Existing: New(From Plans) ConIment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low I BLOCKS Ndmber Name Area Volume 1 Entire House 1753 14024 SPACES Nlmber Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M.BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400, No 0 1 Yes Yes Yes 1Q HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS vi # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft2 ____ 0 1 0 2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft2 ---- 0 1 0 3 Slab-On-Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft2 ---- 0 1 0 4SIab-On-Grade Edge Insulatio M. BATH 7 ft 0 61 ft2 ---- 0 1 0 5 Slab-On-Grade Edge Insulatio LAUDRY 1 ft 0 36 ft2 ---- 0 1 0 4/3 2017 1:21 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM F!405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab-On-Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 ____ 0 1 0 7 Slab-On-Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 ____ 0 1 0 8Slab-On-Grade Edge Insulatio KITCHEN 11 ft 0 209 ft2 0 1 0 9 Slab-On-Grade Edge Insulatio BATH 5 ft 0 50 ft2 ____ 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 ____ 0 1 0 11SIab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft2 ____ 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft2 ____ 0 1 0 I ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1847 ft2 292 ft2 Light 0.6 No 0.9 No 0 18.4 I ATTIC V I # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N I � CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic(Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic(Vented) M.BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic(Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic(Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic(Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 8 Under Attic(Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood 9 Under Attic(Vented) BATH 30 Blown 50 ft2 0.1 Wood 10 Under Attic(Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic(Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic(Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood I WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below IAI;;11 Type Et In Et In Area Eraction Ahqnr Ornt In 0 1 NE=>W Exterior Concrete Block-Ext In9MASTER BE 4.1 16 0 8 0 128.0 ft2 0 0 0.5 0 2 SW=>E Exterior Concrete Block-Ext InsMASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 3 NW=>S Exterior Concrete Block-Ext IndMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 4 NE=>W Exterior Concrete Block-Ext IndMASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 4/3/2017 1:21 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WALLS Adjacent Space CavR_Vaity Width Height Sheathing Framing Solar Below s Ornt Et Aren - 5 NE=>W Exterior Concrete Block-Ext InsuM.BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 6 NE=>W Exterior Concrete Block-Ext InfiffDR00M 2 4.1 12 0 8 0 96.0 ft2 0 0 0.5 0 7 SW=>E Exterior Concrete Block-Ext IndANING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.5 0 8 NW=>S Exterior Concrete Block-Ext InMNING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.5 0 9 SW=>E Exterior Concrete Block-Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.5 0 10 NE=>W Exterior Concrete Block-Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 11 SE=>N Exterior Concrete Block-Ext Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 12 SW=>E Exterior Concrete Block-Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 1I3 NE=>W Exterior Concrete Block-Ext InJ3ffDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 _1I4 SW=>E Exterior Concrete Block-Ext IndKDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 1I5 N=>SW Garage Frame-Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>N Insulated FOYER None .39 3 3 6 8 21.7 ft2 I WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single Yes 0.54 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>W 5 Metal Low-E Single Yes 0.54 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 NE=>W 6 Metal Low-E Single Yes 0.54 0.25 16.2 ft2 1 ft 0 in 1 ft 4 in None None 4 SW=>E 7 Metal Low-E Single Yes 0.54 0.25 39.8 ft2 1 ft 0 in 1 ft 4 in None None 5 NW=>S 8 Metal Low-E Single Yes 0.55 0.25 40.0 ft2 8 ft 0 in 1 ft 4 in None None 6 NE=>W 13 Metal Low-E Single Yes 0.54 0.25 16.2 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 I GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 11 I INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82 168.92 .2598 7 4/3/2017 1:21 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 HEATING SYSTEM =I # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 I COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 I HOT WATER SYSTEM # S stem Type SubT a Location EF Ca Use SetPnt Conservation YYP P 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None I SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 I DUCTS - Supply--- ----Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 325 ft2 Attic 95 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar Apr May ri Jun ri Jul [X Augrl Se Oct Nov H Dec Heatin Jan HFeb Mar f Apr I May Jun Jul E AuSeP Oct Nov Dec Ventin Jan Feb X Mar [X]A r May Jun Jul Aug Se [X]Oct HX Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/3/2017 1:21 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City,State,Zip: FT. PIERCE,FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation alls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. i Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. i Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. i Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity i spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. i Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. I Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. i Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 4/3/2017 1:21 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. THE WINDSOR, FT. PIERCE, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1224.00 ftz 1 b.Frame-Wood,Adjacent R=11.0 208.00 ftz 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 3 d.N/A R= ftz 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 1753.00 ftz 6. Conditioned floor area(ftz) 1753 b.N/A R= ftz R= z 7. Wi�-Factor: dows** Description Area 11 Ducts R ftz a. Sgl, U=0.54 111.36 ftz a.Sup:Attic,Ret:Attic,AH:Attic 6 325 SHGC: SHGC=0.25 b. (I-Factor: Sgl, U=0.55 40.00 ftz SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency c. 6-Factor: N/A ftz a.Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A ftz 13.Heating systems kBtu/hr Efficiency SHGC: Area Weighted Average Overhang Depth: 2.850 ft. a.Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.250 8. FI for Types Insulation Area 14.Hot water systems z a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ft EF:0.97 b.N/A R= ftz C. N/A R= ftz b. Conservation features None 15.Credits Pstat I certi that this home has complied with the Florida Energy Efficiency Code for Building zKEsz Construction through the above energy saving features which will be installed (or exceeded) .y�� = A?Fo in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant fe Builder Signature: Date:. Address of New Home:\� ��, �Q�lz� City/FL Zip:�5�, �� *�.coD �g�* WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/3/2017 1:21 PM EnergyGauge@)USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 Job: - + wrightsoft® Project Suiinmary Date: Entire House By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL34946 Phone:772466-6799 Fax 772466-6796 Email:-OUICKCALCSWL.COM' Project • • For: WYNNE DEVELOPMENT , THE WINDSOR, FT. PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design 9 g Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design-TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment:Load Sizing Structure 18467 Btuh Structure 17655 Btuh Ducts 6190 Btuh Ducts 9340 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none Humidification 0 Btuh Blower e) . 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 25645 Btuh Method Simplified Latent Cooling Equipment'Load Sizing Construction quality Average Fireplaces 0 Structure 2453 Btuh Ducts .2554 Btuh Central vent(0 cfm) 0 Btuh Heatingg Coolin (none) . Area(ft2) 1753. 1759 Equipment latent load 5007 Btuh Volume(ft3) 14741 14741 Air chan e h r g sJ ou 0.38 0.20 Equipment total load 30652 Btuh E uiv AVF cfm q (cfm) 93 49 Req. total capacity at 0.70 SHR 3.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A"030 Cond 25HBC536A*030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,'15 SEER Heat Ing.input Sensible cooling 24360 Btuh Heating,output 34600 Btuh @ 47°F. Latent cooling 10440 Btuh Temperature rise 27. OF Total cooling .34800' Btuh Actual air flow 1160 cfm Actual.air flow 1160. cfm Airflow factor 0.047 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat. Load sensible heat ratio 0.84 Capacity balance point 34 OF Backup: Input=7 kW, Output=23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - - wrightsoft`. 2017-Apr-1017:19:28 Right-Suite®Universal 2017 17.0.14 RSU08101. Page 1 CC, A CalcslDocumentsMYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N F wrightsoft' RighW@ Worksheet Job: Entire House Date: By. QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS ,AOL.COM 1 Room name Entire House MASTER BEDROOM 45.0 ft 3 Rm�he height 8.4 ft 153.0 ft d 8.0 ft heat/cool 4 . Room dimensions 1.0 x 280.0 ft 5 Room area 1753.0 ft2 280.0 ft2 Ty Construction U-value Or HTM Area number (Btuh/ft2-°F) (Btu 1) or perimeter (ft) (Btuh) ors perimeter (ft) (Btuh Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A4ocs 0.143 ne 4 00 2.55 488 448 1795 1141 192 192 769 489 1A-c1om 1 270 .ne 35;56 70A3 7 0 247 488 0 0. 0 0 1A c1om'. 1 270 :ne 35.56 70.43 „":.16 0 581 :: 1151 0.;'- '0: 0 0 9Ac1om .1.270 _ne 35.56 45:24 16. 0 -. 581 Z39 _01 0. 11 VL 13A-4ocs 0.143 se 4.00 2.55 64 41 165 105 0 0 0 0 11DO 0.390 se 10.92. 11.31 23 23 248 257- 0 0 0 0 13A flocs: , 0 143 sw' 4:00' 255 437' 396 9584 1007` 56 56' 224 143 -.4A5 tom O.TIO .sw 21:58. 2753 41 45 893 1140 0 0 0_ 0 13A4ocs 0.143 nw 4.00 2.55 290 217 867 551 112 79 318 202 1A-c1om 1.270 nw 35.56. 45.24 33 0 1162 1478 33 0 1162 1478 4A5-2omd. 0.770 ,nw 21.56 36.90 41 0 880 1505 0, 0 0 0 P 12C-0sw:- 0:091 c.c ;2`55 128:` .::308 .30_ 8 784 0 .0 C 16A-30md 0.032 - 0.90 2.32 1753 1753 1571 4067 280 280 251 60 F : 22AApl: 0.989 .27.69 0.00, 1753 -153. :4237 0 280 45 .1246 0 6 c)AED excursion 1360 .600 Envelope loss/gain 15594 15385 3970 3561 12 a) Infiltration 2873 810 809 228 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 1000 0 Subtotal Qines 6 to 13) 18467 17655 4779 3789 Less witemal load 0 0 0 0 Less.transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18467 17655 4779 3789 15 Duct loads 1 34% 53% 6190 . 9340 34% 53% 1602 2005 Total room load 24657 26995 6380 5794 Air required(cfm) 1160 1160 300 249 i Calculations approved byACCA.to meet all requirements of Manual 8th Ed. �. wrightsoft- 2017-Apr-1017:19:28 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1 k CalcslDocuments\WYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N -- -wrlghtsofV Right-M Worksheet EntireDate: House Dab QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-46"796 Email:QUICKCALCS AOL.COM 1 Room name WIC M.BATH 2 E)qposed wall 0 ft 7.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 9.0 ft 1.0 x 61.0 ft 5 Room area 63.0 ftz 61.0 ftz Ty Construction U-value Or HTM Area (ft2) Load Area (ft') Load number (Btuh/ft;°F) (Btuh/ftx) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 13A-4ocs 0.143 ne• 4-.00 2.55 0 0 0 0 56 49 10 125 1A-61om 1270 ne 35:56 70.43 0 0 0 .0 . 7 0 247 488 1A1om. 1270 ;ne, 35.56 70.43 0 0 0 0 0 0 0 0 1A c1om:: 1 270_he 35:56 45:24 0 . 0 0 0 0' 0, 0 0 11 W 13A-4ocs 0.143 se ZOO 2.55 0 0 0 0 0 0 0 0 ►-D 11DO 0 390 se 10.92 11.31 0 0 , 0 0 0 0 0 0 13A-flocs. _";0 149 sw -4:00 .2 55 0: 0 ... 0`. .. 0' ' 6 '0 --0 --....0 . 4A5-tom 21t56 27:53 _ 0 _ 0 0 0 ,.0 .0 0 0 1/+/ 13A4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 L�(G 1A-clom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2omd 0.770 nw 21.56 36.90 0 0 0 0. 0 0 0 0 P. . 'i:12C-0sw 0.091 2:55'i` 1:28 0 0% 6 0 -.0-... ..: 0 `- -::0 •0 C 16A30md 0.032 - 0.90 Z32 63 63 56 146 61 61 55 142 22A bpl U189 27.69` 0.00 63 . 0 0'. 0 61 . 7 194; 0 6 c)AED excursion -5 -26 Envelope loss/gain 56 141 692 729 ,12 a) Infiltration 0 0 120 0 b) Room ventilation 0 0 113 Internal gains: Occupants @ 230 0 0 0 0 ` Applianceslother 1 0 0 Subtotal(lines 6 to 13) 56 141 817 764 Less edemal load 0 0 0 0 Less transfer 0 0 0 0 0 0 0 0 Redistribution 53% 274 0474 56 404 14 Subtotal 1 75 34°l° 15 Duct loads 34°l0 53% 19 1091 1168 Total room load 74 219 51 50 i Air required(cfm) Calculations approved b ACCA to meet all requirements of Manual J 8th Ed. Pp V Q � -I* wr.ightsoft' 2017-Apr-10 17:age 2� Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N i -+�-wrightsoft, Right-J®Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name LAUDRY BEDROOM 2 2 Bposed wall 0 ft 12.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 6.0 x 6.0 ft 15.0 x 12.0 ft 5 Room area 36.0 ft2 180.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross I N/P/S Heat Cool 6 13AAocs 0143 ne. 4.00 2.55 0 0 0 0 96 80 319 .,203. I c1om 1 270 he 35 56 Z0.43 0 0 0 0 0:: 0 0 ''>'0; 1Ac1om 1 D ne_ 35-56 70.43 , 0' 0 0 16 0 -:581 115T 1Ac1om._ .1.270 .ne .35.56 A5.24 0 . 0 0. 0 0 0-. 0 0 11 y✓ 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 �p 1100 0.390 se 10.92 11.31 0 0 0 0 _ 0 0 0 0 W 13A-0ocs' :0 143 'sw= _4.00 2.55 0 0, ...:_- 0 0 0 . 0 0 -0 �G 4A5 tom : 0.770 ;sw 21.56: :27:53 - 0 0 0 0 0' 0 _. . : 0 .0 13AAocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1A-c1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2omd; 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 :p` -:; 12G-0gw: ;.. 0:091 - _ 2 55'. ..1.28 0 .0. 0 0.." 01 0. .: :.:0 0 C 16A-30md 0.032 - 0.90 2.32 36 36 32 84 180 180 161 418 P ,,: 22A-tpl::_ 0:989 . ._: .27.69" 0:00 36 0 0 180- .: 12 332; 0 6 c)AED excursion _3 _60 Envelope loss/gain 32 81 1394 1711 12 a) Infiltration 0 0 216 61 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Qines 6 to 13) 32 81 1609 1772 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 6 14 14 Subtotal 38 95 1615 1786 15 Duct loads 34% 53% 131 50 34% 53% 541 945 Total room load 51 145 21 2730 Air required(cfm) 2 6 10101 117 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A -F[I-- wrightsoft-. Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page3 k CaIcskDocuments\WYNNE-THE WINDSOR-REVISED.rup Cale=MJ8 Front Door faces: N - -wrightsoft* Right-M Worksheet Job: Entire House Date: QUICK CALLS, INC. By. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772466-6799 Fax 772-46M796 Email:QUICKCALCS AOL.COM 1 Room name DINING/GREAT ROOM KrrCHEN 2 Exposed wall 50.0 ft 11.0 ft 3 Room height 8.9 ft heat/cool 8.9 ft heat/cool 4 Room dimensions 1.0 x 588.0 ft 19.0 x 11.0 ft 5 Room area 588.0 ft2 209.0 ft2 Ty Construction U-value. Or HTM Area (ft2) Load number (Btuh/ftz°F) (Btuh/ftz) or perimeter (ft) (Btuh). ors perimeter (ft) (Btuh) Heat Cool . Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0143 ne 4.00 2.55 0 0 0 0 0 0 0 0 1A-c1om 1270 ne 35.56 70.43 0 0 0 0: 0 0 0 0 1Ac1om _ 1 270 ne 35.56 70.43 0 0 .. 0. 0 '.. 0: 0 0 "0 1Aclom 1 270 ne . . 35i56 4524 . 0 0 0.:. 0 0. 0:- 0 -:0 11 V)/ 13AAocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 �p 11DO 0390 se. 10.92 11.31 0 0 0 0 0 0 0 0 13A-0ocs.,. 0143 5w. 4 00 255 -. 267 226 :-.903 574 98 98 `.392 249: 4A5.2om. 0.770 sw 21:56_ 27:55 41 22 893 1140 0 . . 0 0 0. 13A-4ocs 0.143 nw 4.00 2.55 178 137 549 349 0 0 0 0 ♦-!' 1A-c1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 L-( 4A5-2omd 0.770 nw 21.56. 36.90 41 0 880 1505 0 0 0 0 P •.::12C-09w 0.091 2:55 ' 128 0. 0 0 0. 116. 116 295 148 C 16A-30md 0.032 - 0.90 2.32 588 588 527 1364 209 209 187 485 F 22A-tpl .:_ 0989 . ._,: 27.69 0.00•. .588 50 ' '1385 : 0 a 209. 11 305 .:0. 6 c)AED excursion 1004 -64 Envelope loss/gain 5136 5937 1179 818 12 a) Infiltration 1000 282 220 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 1000 Subtotal(lines 6 to 13) 6136 6679 1399 1880 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 0 0 14 Subtotal 6142 6693 1399 1880 15 Duct loads 1 34% 53% 2058 3541 34% 63%1 469 995 Total room load 8200 10234 18V 2875 Air required(cfm) 386 440 88 124 Calculations approved byACCA to meet all requirements of Manual J.8th Ed. - - wrightsoft' Right-Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-101 Page 4 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc=MJB Front Door faces: N wrightsoft° Right-J®Worksheet Job: Entire House Date: QUICK CALLS,INC. By. 3117 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772466-6796 Email:OUICKCALCS@/AOL.COM 1 Room name BATH HALL 3 Room height I he 9h 8.0 ft 5.0 ft heat1cool. 8.0 ft 0 ft heat/cool 4 Room dimensions 10.0 x 5.0 ft 5.0 x 5.0 ft 5 Room area 50.0 ft2 25.0 ftz Ty Construction U-value Or HTM Area (ft-) Load Area 2 ft Load number (Btuh/ft2--°F) (Btuwftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 13A-4oc.s 0143 ne 4 00 2.55 40 40 160 102 0 . 0 0' 0 1A c1om 1.270 ne 35 56: 70.43 0 0 0 0. 0' 0 0 0. 1&, .lom :: 1:270 ne 35;56 70.43 0 0 0 0 0 0 0 '0 "1Ac1om• .1.270. ne 35:56: 45.24. 0 0 0 .0, o . :. 0 .. 0 -o 11 VI! 13A-0ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 �D 11D0 0..390 se 10.92 11.31 0 0 0 0 0 0 0 0 13AAocs` 0.143 sw, 4.00 2.55 0 0 0 ` . . 0 p p 0 0 �G 4Ar2om: 0.770 .aw 21.5ti. '27.53 0 0 0. 0`:. 0.: 0 0 0 13AAocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2omd- 0.770 nw 21.56.. 36.90- 0 0. 0 0 0 0. 0 0 P 12C-0sw:; .` 0.091 '2[55 - - 1:28 0: 0 . 0 0 0 0 0 0. C-. 16A-30md 0.032 0.90 2.32 50 50 45 116 25 25 22 58 F 224 tpl 27 69 0.06 5o 5 138 . .., 0 25 - 0 61 0. I - 6 c)AED exursion -8 -2 Envelope loss/gain 343 210 22 56 12 a) Infiltration 90 25 0 0 b) Room ventilation 0 0 0 0 13 j Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Qines 6 to 13) 433 235 22 56 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 -22 -56 14 Subtotal 439 249 0 0 15 Duct loads 1 341/6 53%1 147 132 34%1 53% 0 0 Total room load 586 381 0 0 Air required(cm) 28 16 1 01 0 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. - - wrightsoft' 2017-Apr-10 17:19:28 A Right-Suite®Universal 2017 17.0.14 RSU08101 Page 5 k Calcs%Documents\WYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N -= Job: wrightsoft Right-M)Worksheet Entire House Date: QUICK CALCS, INC. By: 317 S7 LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:OUICKCALCS@,AOL.COM 1 Room name FOYER BEDROOM-3 2 Exposed wall 9.0 ft 14.0 ft 3 Roam height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 92.0 ft 13.0 x 13.0 ft 5 Room area 92.0 ft2 169.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (BtuWft'L-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Stuh) Heat Cool Gross NIPIS Heat Cool Gross WRIS Heat Cool 6 134.4ocs 0.143 ne 4 00 2.55 0 0 0 0 104 88 351 223. 1A-c1om 1.270 ne 35 56 70.43 0 0 i 0. 0 0, 0. .0 .. 0 1A=c1om 1 270 ne. 35 56 _ 70.;M. 0 0.. : "0 0 0 0 0 p Xc16m - 1:270 ne' . 35:513t :45.24 :0. 0 -0 0 16" 0.. 581 -739 11 13A4ocs 0.143 se 4.00 2.55 64 41 165 105 0 0 0 0 1100 0.390 se 10.92 11.31 23 23 248 257 0 0 - 0 0 V�I M-466s 01.3 sw 4 00 2 55;: 8 g '-32': 20 8. 8 32 ... 20 G; 4A5 tom 0.770 aw. 21 56.: .=27.53 0 0 0 0 0 0 0 - 0 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 IA-clom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2omd 0.770 nw 21.56• 36.90 0 0 0 0 0 0 0 0 P.`' . ::. 42C 0sw 0 001 _ 2.55. .1:28 88 98 -2241 113. 104 .. 104' 265: 133 C 16A 30md 0.032 - 0.90 2.32 92 92 82 213 169 169 151 392 F. _..., '22/ tp1 0989 27:69 0.00. . 92 g 249 0 : 169 94 388 0 6 'c)AED excursion -25 -52 Envelope losstgain 1002 684 1768 1456 112 a) Infiltration 162 46 252 71 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appiiances/other 0 0 Subtotal(lines 6 to 13) 1163 730 2020 1527 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 114 Subtotal 1163 730 2020 1527 115 Duct loads 34%1 53%1 390 386 34% 53°Io 677 808 Total room load 1553. 1116 2697 2335 Air required(cfm) 73 481 1271 100 i Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. f�C -Fp- wrightsoft- 2017-Apr-10 17:19:28 GA Right-Suite®Universal 2017 17.0.14 RSU08101 Page 6 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Cale=MJ8 Front Door faces: N Duct System Summary Job: +l+ wrightsoft Y rY Date: Entire House By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772466�799 Fax 772-46676796 Email:,QUICKCALCS@AQL.COM I Project a • - • •: For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O' Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/.return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.273 in/100ft 0.273 in/100ft Actual air flow 1160 cfm 1160 cfm Total effective length CrEL) 183 ft SupplyDetail Tab,le I Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Mat Ln (ft) Ln(ft) Thank BATH h 586 28 16 0.372 4.0 Ox0 VIFx .19.5 115.6 st1 BEDROOM 2 C 2730 101 117 0.384 7.0 Ox0 VIFx 15.0 115.0 st1 BEDROOM 3 h 2697 127 100 0.353 6.0 Ox0 VIFx 26.8 115.0 st1 DINING/GREAT ROOM C 3411 129 147 0.292 7.0 OxO VIFx 36.5 135.0 st2 DINING/GREAT ROOM-B C 3411 129 147 0.371 7.0 Ox0 VIFx 19.9 115.0 st1 DINING/GREAT ROOM-C.0 3411 129 147 0.278 7.0 Ox 0 VIFx 44.9 135.0 st2 FOYER h 1653 73 48 0.490 4.0 Ox 0 VIFx 7.0 95.0 KITCHEN C 2875 88 124 0.366 6.0 OxO VIFx 21.8 115.0 st1 LAUDRY c 145 2 6 0.371 4.0 Ox0 VIFx 19.9 115.0 st1 M.BATH h 1091 51 50 0.282 6.0 Ox 0 VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 150 124 0.273 6.0 Ox 0 VIFx 48.4 135.0 st2 MASTER BEDROOM-A h 3190 150 124 0.284 6.0 Ox 0 VIFx 40.9 135.0 st2 wlc C 216 4 9 0.292 4.0 Ox0 VIFx 36.0 135.0 1 St2 Supply Trunk Detail • - Trunk Htg. Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material. Trunk �st2, Peak AVF 612 602 0.273 780 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1087 1112 0.273 796 16.0 0 x 0 VinlFlx I wri htsofta 2017-Apr-1017:19:29 9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1 ...k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N e TableReturn Branch Detail Grille Htg . Clg TEL Design Veloc Diam H x W Stud/Joist Duct. Name Size(in) (cfm) (cfm) (ft). FR (fpm) (in) (in) Opening(in) MatL Trunk rb1 Ox0 1160 1160. 0 0 0 0. Ox 0 VIFx I 4 wri htsoft 2017-Apr-10 17:19:29 9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2 CK ..k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc=MJ8 Front Door faces: N