HomeMy WebLinkAboutBuilding plans, 1709-0266Gulf Coast Supply and MFG Sv Crimp Metal roofing FL #11651.12
26 ga. Sv crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 0 end
laps fastened with corrosion resistant tin caps and with 1.25" ring , shank nails
2
..
2"
El ®
5/8" thick light textured
® rTD
°
stucco on typc al concrete
block construction
LEFT ELEV
5/8" thick x 8"w cut
coral finished stucco bands
ATION
12° 5/8" thick x 8"w cut
H. coral finished stucco bands
SCALE: 1/4" = I'-O"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411651.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and C end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c, at all laps and two staggered rows 12" o.c.\field. Attach
deck to trusses using attachment detail on this sheet
3
�5/8" thick light textured
stucco on typical concrete
block construction
—
-------------------——————————————————————————————————— — — — — —— o,_o„
Finish Columns with
5/8" thick cut coral
finished stucco bands
5/8" thick x 8"w cut I
coral finished stucco bands
ELEVATION NOTES:
Gulf Coast Supply and MFG Sv Crimp Metal roofing FL #114SL12
26 ga. 5v crimp metal roofing attached to plywood deck using 3*9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced C o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet \
12
SLOPE
— — — — — — — — — — — — — — — — — — — — — — — — — — — — —
6/8" thick light textured
stucco on typical concrete
block construction
REAR ELEVATION
— Overhangs at 1'-0" unless otherwise noted on Roof Plan
— Roof pitch at 4:12 unless otherwise noted
— Any changes to this plan shall be submitted to the architect
for approval in writing prior to starting construction.
— Return ALL Stucco Bands Into Window or Door.
12
SLOPE 4
RIGHT ELEVATION
SCALE: 1/4' = I'-O"
5/8" thick x 8"w cut
coral finished stucco bands
Finish Columns with
5/8" thick cut coral
finished stucco bands
Gulf Coast Supply and MFG 5v Crimp Me
26 ga. 5v crimp metal roofing attached to
wood screws with self sealing washer at 12"
(type 2) 30 lb felt underlayment installed
laps fastened with corrosion resistant tin c
?aced 6 o.c, at all laps and two stagger
dpeck to trusses using attachment detail on
SCALE: 1/4" = 1'-0"
tat roofing FL #11651.12
plywood deck using #9 x 1.5"
o.c, max spacing over ASTM D
with min. 4' side laps and 6" end11
�r"`tou
gT.LUOTV CO— A IL E v�
EF�FV\EDB EKEP'f 0
VIE
ST A
PLANS � YEC'C10 NILLBED'iADE.
OR so
M
12"
�Ay BE COMPLY WITEBEAMY IN ORDER TSOTHAi
N ALL APPLICA@LE COoEO,
CONCEALECrAS1ENEgS
APE TNESESPoN&81L yy00FT8EENTS
CON r1MCE0'10F4EC0gD
3O$
aps and with 1.25 ring shank nails
edhiso sheet o.c. din field. Attach TERMITE TREATMENT REQUIRED
ALL MANUFACTURES LABLES SHOWING
U FACTORS AND SHGC COMPLIANCE
WrM FBC ENERGY CODE MUST
REMAIN ON ALL DOORS AND WINDOWS
1/8" Thick cut coralUstucico over hVgp"OVED
backed wire lath nailed to substrate through
�toeba yl9/32"er of 15lb CDXeIFiguwood 8nailedls. at 4"
oorcate
in field and edges with IOd ring shank galvanized
nails into truss webbing.
12
SLOPE 14
' �' I�I� II�V '�I�I deli
■ ■ III II�II III ',III
QU III II[�`II III II�II
' IN
-IIII�IIII�III�I!
5/8" thick light textured
stucco on typical concrete
block construction
FRONT ELEVATION
SCALE: 1/4" = I'-O"
l
--- 5/8" thick x 8"w cut
coral finished stucco bands
-0'-4" A.F.F.
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP
I/2" drywall ceiling on truss bottom cord AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
2" x 4" top plate
I/2" drywall on
x 4" studs at 16" o.c.
base -board \ 11 11 / 2' x 4" P.T. bottom plate
\ 4" concrete slab with fibermesh OR
Cx6" #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
Interior Non —Bearing Partition
nts
PERMITTING INFORMATION (FORM 100)
Florida Building Code Residential: 5th Edition and ASCE 1-10 for Wind Loading
Building Design is: Enclosed Risk Category: II Wind Velocity: 145 mph ultimate
Mean Roof Height: II'-O" Roof Pitch: +' 2
Internal Pressure Cooee`Tircient: ±0.18
T�i5
Subjectabilitg to damage from: Weathering: Negligible Termites: Veru Heavu
Width of Roof End Zone: 3'-4" Wind Speed: 165 mph ultimate
Wind Exposure Classification: C
ITCH
Adjustment factor for Exposure Height: 1.21 x 0.4 = 0.124 ASD desiggn
Load Combination: ASCE 1-10 Section 2.4 DL+LL; DL+0.6WL; 0.6DL+0.61DL
Components t Cladding Wind Pressure (NET) Roof Zone: I. +20.6/-32.6 psf
Roof Zone: 2. +20.6/-51.0 psf
Roof Zone: 3. +20.6/-84.0 psf
Components t Cladding Wall End Zone Width: 3'-4"
Components t Cladding Wind Pressure (NET) Wall Zone: 4. +35.8/-38.1 psf
0 = Roof Zone I
Wall Zone: 5. +35.8/-41.8 psf
Walls Zone 4
Components t Cladding Wind Pressure (NET) on Garage Door:+32.0/-40.3psf
Shear Walls Considered for Structure? Yes
EM = Roof Zone 2
Continuous Load Path Provided? Yes
Walls Zone 5
Are Components an Cladding Details Provided? Yes
END ZONE
Minimum Soil Bearing Pressure.2.500 psi, Presumptive: X Bg Test: psi
This Building Shall Have the Following:
- Corner Zones
APPROVED SHUTTERS: X IMPACT GLASS: BOTH: NEITHER:
Roof Zone 3
ROOF LIVE LOAD: 31 psf ROOF DEAD LOAD: 10 psf
FLOOR LIVE LOAD: psf FLOOR DEAD LOAD: 10 psf
JOB ADDRESS: \ cc<-G<-\cl,
FLOOR
Ic�,ll CRASH POST DETAIL
TYPICAL NOTES: SCALE 1/4" = 1'-0" N.T.S.
I. Contractor to verify ALL notes and dimensions prior to ste high by 4" diameter
steel crash post. Floor
proceeding with work. Flange with 4 - 3/8"
2. Contractor to STRICTLY enforce ALL OSHA Requirements, expansion bolts into
3. ALL Lumber to be used as Beam, Rafters, etc... to have slab (3/8"t 50 ksi steel plate)
a minimum 1,400 P.S.I. fiber Stress. `
4. No dissimilar metals to touch. 2%° 2!2"
S. ALL Concrete used for slabs shall be min. 2,500 PSI concrete. %_" %_'
ALL Concrete used for vertical filled cells, cont. tie beams etc.. to 0
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix '3/8"° 2i/,"
6. Drywall at ceilings shall be leveled and attached to bottom chord 4'
of trusses with screws per FBC R102.3.5. ° ° 2/'
FLAN
1.
ALL Wood in contact with concrete shall be pressure treated.
8.
ALL wall dimensions are nominal and not finished wall or stud dimensions.
9.
ALL plumbing fixtures to be low flow.
10.
Contractor to Provide Drain at water heater in accordance
With the current edition of the Florida Plumbing Code.
II.
Contractor to Provide a 2'-8" wide door at one bathroom for
handicap accessibility requirements.
12.
Lowest finished floor to be set by Governing Building Department
surveyor to set in field.
13,
Separation between residence and garage shall be per FBC R302.6
14.
Door between garage and residence shall be 1-3/4"t 20 min. rated door
w.H. = Water Heater in Pan With Drain
15.
Wall and Ceiling shall have a flame -spread classification of not greater than 200 per
FBC R302.9.1
1(.
Wall and ceiling finishes shall have a smoke -developed index of not greater than 450
per FBC R302.9.2
11.
All exposed attic insulation materials installed on attic floors shall have a critical radiant I" x 6" P.T. Buck to
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation
nailed
block with case hardened nails
materials exposed on the underside of the roof deck or on the attic walls shall comply
prior to door attachment
with F.B.C. R316 - see permit info box of code edition
18,
Gyypsum board material shall conform to ASTM C36, C79, C475, C514, C630, C931
C1396 be
6
C960, C1002, C1047,CIIl7, C1118, C1218, C1395, or and shall installed
according to the following: (FBC R102.3.5)
Drywall
Thickness
Location
Orientation
Framing
Member
Max spacing
of fasteners
Nail sizing options for
g
drywall into
Spacing
Maximum
installation of
wood framing members
Nails
Screws
2" x min. thickness
Ceiling
Perpendicular
24"
7"
12"
13ga 13/8" long with 19/64" head
0.098" diameter x 1 1/4" long
annular -ringed or 5d cooler nail
0.080" di . xx 1 5/8" long with
Walls
Either
IL"
8"
16
Direction
15/44" head
OR
Gypsum board nail 0.0&" dia.
x 1 5/8" with 9/32" head.
Ceiling
Perpendicular
24"
ill
12"
13ga I S/8" long with 19/64" head
OR
0.098" diameter x 1 3/8" long
annular -ringed or 6d cooler nail
5
/
OR
0.092" dia. xx 1 1/8" long with
Walls
Either
I6"
g°
it.,
I6
Direction
114" head
OR
Gypsum board nail 0.0915" dia.
x 11/8" with 19/64" head.
Install SGD thru buck into
block with 3/16" tap -con with
11/2" penetration at C o.c. max.
from each corner and 20." o.c. max
thereafter at head per product approval
Use 3/16" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product approval
19, ALL ceramic tile surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, Ala6.1 and A131.1
20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR C11-18 and installed I.A.W. manufacturers recommendations shall
be used as backer for the wall tile in tub areas and wall panels in shower areas.
21. Insulation including facings such as retarders or vapor permeable members installed
within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accompanying smoke
developed index not to exceed 450 when tested in accordance with 4STM E 84.
Insulation shall comply with F.B.C. R316.
Gulf Coast Supply and MFG Sv Crimp Metal roofing FL #11651J2
26 9a. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c, max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 0 end
laps fastened with corrosion resistant tin cape and ring shank nails
spaced 6 o.c. at all laps and two staggered rows 12" o.c. In field. Attach
deck to trusses using attachment detail on this sheet
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) IOd x 1 1/2" nails
( 24" o.c,) su p�t�pg Max.
18101bs. uplift
Aluminum Drip -
Edge t Fascia
2" x 6" Sub-F
Kaycan full o vent vingl soffit installed
using 1/8" dia shank x 15" long gals.
roofing nails with 3/8" dia. head per
product approval #11-0314.01
6/8" thick light textured
stucco on typical concrete
block construction
u5 bar vert. w/
30" overlap -
at each filled cell
Grade
TYFICAL
12
4 1�
W coil
Base
SEC70N
PRE-ENGINEERED TRUSSES
at 24"o.c. TYPICAL
(shop drawings by manufacturer)
\R-30 blown fiberglass
in bottom chord of trusses
-1/2" drywall with smooth finish
Two rows of beam block filled with concrete
_and (U 45 bar cont. in each row. substitute
precast lintel filled with concrete and (U tt5
bar cont. for bottom row over openings
1/2" drgwall over I" x furringg
strips at 14," o.c. with R4.1 fr-Foil
-insulation on typical Sill Block walls
All drywall to be installed per FBC R102.3.1
and shall meet all pertaining ASTM codes.
Mortar to be Type "M" only proportioned per FBC R601.1
and Mortar Jonts shall comply with F$C R601.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
Fill cell with concrete and
(1) tt5 bar vert. (typical).
-Max. spacing shall not exceed
48" unless otherwise noted
see Foundation plan notes for
spacing at openings
4" concrete slab with fibermesh OR
6"x4" U10/10 WWM on 6 mil Visqueen over
/ clean compacted termite treated fill
14" x 14" Concrete footing
with (2) US bars cont. and tt5
transverse bars at 48' o.c.
Scale : 1/2" = 1'-0"
Masonry Beam
01Iru
Lu -
fixed door
sliding door
11/2"
Bottom Track DTI
Sliding Door Detail
At Masonry Wall NTS
AREA CALCULATIONS
Living A/C = 1646 sq. ft.
Front Porch = 141 sq. ft.
Garage = 321 sq. ft.
Total Under Roof= 2108 sq. ft.
Total Cubic Ft = 15,412A
2" VTR
JAL
I
1
I
21' VTR
Masterr�� Jib
Bath
I
IL v: I
2" 1
Lov.
4" 2" VTR
3C. JIL
1 I
2' 3.
slier.
Kit. sink I
I
Kitchen 2" I
I
I
Lay. r4
3"
W.C.
Bath u2 shwr.
3'
C.O. To septic
PLUMBING RISER
I" x 6" P.T. Buck nailed to
block with case hardened nails
prior to door attachment \
Masonry Wall
al Flooring
Install SGD thru buck into
block with 3/16" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at Jambs per product approval Jamb
Window
Schedule
Mark
Size
Rou O en.
h
Window Description
PRESSURE ZONE
I.
4'-5%"x 5'-3%8"
54V'x 63i;'
Single Hung
ZONE 4
2.
C-2is"x 5'-3 %s"
15" x 63 %4"
Single Hung
ZONE 4
3.
2'-2" x 3'-2 1/2"
1 21Y2"x 38%s"
Single Hung
ZONE 4
4.
4'-5%s"x 4'-2 %."
1 54%s"x 50i/4"
Single Hung
ZONE 4
ALL
Windows to
be aluminum
windows w/ tint
and mullions per
elevations.
ALL
windows to
withstand pressures in permit info box on
sheet 1
ALL
windows in bathrooms to
be tempered
All
rough opening dimensions
to be verified bg contractor
with
manufacturer
s specs prior to construction
Door Schedule
7
Mark
Size
Rough Opening
Door Description
PRESSURE ZONE
A
9'-0" X 1'-0"
108" x 84"
Overhead Garage Door
ZONE 4
B
3'-0" X 6'-8"
41" x 83 %2"
Fiberglass Panel - Inswing
ZONE 4
C
6'-0" X 6'-8"
14" x 81 %2" ;i ; ;°»°"
Sliding Glass Door
I ZONE 4
D
2'-0" X 6'-8"
Solid Core - Wood
- 6-Panel -Bi-Fold
Finished 24" x 81 %"
E
2'-6" X 6'-8"
Solid Core - Wood
- 6-Panel
F
5'-O" X C-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
G
2'-8" x C-8" x 1 %;'
Solid Core Wood, Steel, or Masonite Door
H
2'-8" X 6'-a"
Solid Core - Wood
- 6-Panel
J
2'-6" X C-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
K
2'-8" X C-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
ALL Exterior doors to withstand pressures stated in permit info
box on sheet #1
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET 41
All rough opening dimensions to be verified by contractor
with manufacturers specs prior to construction
a
34'-O"
_ 1'-5" 5'-II" 13'-8" T-O"
DO
O 00 O O 00 00
00
O
EGRESS
Ln
O
0
o
SITTING ROOM
B
8'-0" A.F.F.
Flat Ceding 12'-8co
I
�
O
®
(V
d
1 Zia
,n
I MASTER
o
BEDROOM
_v
com
8'-O" to 9'-Sill A.F.F.
^
Vaulted!IRV Ceiling 8'-0" A.F.F.
CD o mw
Flat Ceiling
R
~N
G AT
RgOM
°
I O
o
D
I
Rod Shelf
O
19' 8" 61- 4' 6'-0"
=r
N
I I Vanity to be
�, a 34 y2"high
I
°
I
u)
H.B.
Ln
-
N I
O cn
I
r I
A F.F.
to 9'-8" 2" x 6" knee -wall
Vaulted Ceiling) below top O
°
counter M rr
I
r
DINING I
ROOM i 6i a�6` 6 LRod Shelf _
ALINIE
B NET
e i W
O
°
Q
4
Lu
O
ffi
Vanity to be iBAT
O
34 y2" igh I ✓�° °
iv
II' -o 3/4u High Wall
IUlall
° 'KI' i"CHEN
o I 3'_8" m
m
I - - - - J O
Vent I
throug
rwall
�vleng
1
0 8'-O" A.F.F.
° Flat Ceiling
H.
4'-I" 0'-5" -0"
1 D
O E Upper cabinets to
extend over Ref.
" 1
1
2" filler
�\ T
/- c an Ref.
3L' .9
4'_O"
ff22��wiay� _
i orYtraY 3pamng
O Rod t Shelf
W _4"4 Steel Ballard
O> 1 v Il" Provide auto
#1
r
Attic Access closer
with light
L J
O
A.F.F. Q Q - - - _ _
(- 22" R-II Batts Insulation
R
Uc
-
_ Flat Ceiling
°�4a
m� n'-6" 6,_O„ 150 Amp
i�anel
Meter
~Qu
IN
O SECOND �' ©
BEDROOM GRESS Y GARAGE
° O T OO e'-4" A.F.F. O
Flat Ceiling
in
o
N
° a
° EGRESS r-----------------�
O
Block wall in
garage to be
-
O struck block
1
O L I I
O
C VER D
O
12" x 12" concre a column bloc filled
p
ith concrete and (2) #1 bars v rt. Ued O R C I 4'-6"
into II tels above
:a
6' 2"
I ® I
o Hp I
O
C`!
-
° ° o0 00 0o
ao
4'-2"
2'-Sill
2'-Sill
9'-6"
3'-4"
Install windows thru buck into
block with 3/14" tap -con with
1 1/2" penetration at L" o.c. max
From each corner and 20." o.c. max
thereafter at ambs and 20" o.c. max
Exterior face at head and sill per product approval
OF wall ---\ / \ Buck to be I" x 4' PT
�_I"x4" P.T. Buck nailed to
block with case hardened nails
D e t a 1 l at UJ I n d OW S prior to window attachment
Braden It
Braden AIA, FA
Architects
- Planners
411
S.E. Coconut Avenue
Tel :
(112) 281-8258
Fax
: (112) 281-8283
E-mail:
bradenaia8comcast.net
Stuart. FL
34996 UAAC000032
NTS
WQnne Building Corp.
�2' Grand Carlton
Spanish Lakes
St. Lucie County Florida
INSTALL VULKEM BLOCK SEALANT
ON ALL JAMB, HEADER, AND
SILL BLOCK PRIOR TO BUCK
INSTALLATION
GARAGE
f f RIGHT
SITTING
ROOM
Exterior face
Of way --\
Attach buck to block wall with
1/4" dia. Elco conc screws with min.
1 1/4" penetration at 12" o.c. max
and 4" max from each corner thru
2" x 6" PT Buck
Uetall at Joor
)ate Drawn Revisions
8-24-11
Drawn by:
C.C.U.
Checked by:
D.R.B.
crews thru Jamb into bi
ige and 15" o.c. max at
prior to door attachment
NTS
Sheet I Comm 9
2. 112-2c
OF 5 j
TRUCTLJRAL. NQTE5:
2
3
4
5
4
l
Ig
ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL
9.
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS
Ic
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
BE 3000 PSI OR 4,000 PSI GROUT MIX AT 28 DAYS
POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
II.
GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 6X6 I0/10
WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
12
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT IN. FILL TO BE SPREAD IN 12" LAYERS AND
13
MACHINE COMPACTED TO A MINIMUM OF 2500 PSI IN AREA OF
BUILDING CONSTRUCTION
TEST FOR FILL COMPACTION MINIMUMS PRIOR TO FORMING SLAB.
14
GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
G
ATTENTION OF THE ARCHITECT.
14
GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
FOUNDATION PLAN), PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
I�
FOUND/4710N FL/4N
SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
DESIGN LOADS ARE AS FOLLOWS:
ROOF (DL+LL) = 41 PSF
WIND VELOCITY = PER PERMIT INFO BOX ON SHEET 41
EXPOSURE ="C"
ALL REINFORCING STEEL SHALL BE GRADE 60, MEETING ASTM A-16, d
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 301 STEEL.
ALL DOWELS, SLEEVES, CONDUITS, INSERTS, SLOCKOUTS, ANCHOR
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTING: 3"
BEAMS: 1-1/2"
LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1600 PSI
ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000
PSI OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE.
ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
I. Any changes to plans must be Submitted to the architect
for approval before proceeding With construction.
2. Contractor shall be responsible for verification of all
notation and dimensions before starting construction.
3. Soil conditions assumed to be 2500 psf. Should any other conditions be
encountered, the architect shall be notified in writing for revision
4. Verify all recess thickness at showers, tile, etc....
5. Contractor to provide filled cell With concrete and 1 95 bar vert. at 48"
o.c, max. Provide (1) filled cell on each side of openings upp to 5'-II" wlde.
Provide (2) filled cells on each side of Openings from 6,-O" to 9'-11"
and Provide (3) filled cells on each side of openings from 10'-0" and up
Contractor to See plans for any other condition used. Foundation walls
Shall have filled cells at 24" O.C. unless otherwise noted (see section)
(o. Contractor to provide for Form Board Survey - Form Board Survey
to be provided to Truss Company prior to truss construction
7. Contractor to provide for soil test prior to construction and provide
a copy of Sol[ test to architect for review prior to construction
8. ALL Reinforcing steel shall be grade (0, meeting ASTM A-16 and
A-35 specifications. ALL Anchors to be A-301 steel.
9. Provide a minimum of 3" concrete protection at footings and
1-1/2" concrete protection at beams for ALL reinforcing bars.
#5 bar Vert. w/ Thicken edge to 8"x8"
30" overlap SEE TYPICAL with concrete and
at each filled cell ,.SECTIONS one 45 bar continuous
4 concrete slab with flbermesh OR
6 xb" 410/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
E No1111liiiiihd I,, 14"w x 14"d concrete monolithic
11 footing with (2) #5 bars cont.
rl
TYPICAL FOOTING DETAIL
J SCALE 1/2" = I'—O"
4" concrete slab with fibermesh OR
611x6" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
#5 bar cont.
Step per
o foundation plan
Y
atiL.. v Qom.
101, J _' (2) 45 bars cant. bottom steel
12"
DETAIL AT GARAGE STEPDOWN
SCALE 1/2" = I'—O"
12" x 12" concrete column
block filled with concrete
and (2) #-1 bars Vert. tied
into lintels above
Top of footer
16" below finished
Verify house slab
height in field
O"xl6" concrete
footing with (4)
s each way
DETAIL
SCALE 1/2" = 7O"
GRADE
SCALE: 1/4" = 1'-0"
Termite Protection for New
Construction.
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete.
If soil area is disturbed after initial chemical soil treatment
area shall be re -treated with a chemical soil treatment
including spaces boxed or framed.
Treatment must be in accordance with the rules and laws
established by the Florida Department of Agriculture and
consumer services.
Protective sleeves around metallic piping penetrating
concrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termicide in annular space between sleeve and pipe.
4" concrete slab with flbermesh OR
CxC 410/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
PORCH SLAB EDGE DETAIL
SCALE 1/2
#5 bar Vert, w/
30" overlap
at each filled cell
Adjust curb height
based on gar. floor
slope.
#5 bar in curb \
TYPICAL
rIONS
4" concrete slab with flbermesh OR
Vx6" 410/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
E01-011 F.�.
GARAGE
II11=
14"w x 14"d concrete monolithic
footing with (2) #5 bars cont.
14"
CURB DETAIL
SCALE 1/2" = 1`0"
2" x 6"
PT wood secured
with \
3/8"dia.
x C anchor bolt
at 18" o.c.
overhead door track secured to
wood
Jamb per manufacturer's product
approval
Garage
Door Jamb
Detail
GARAGE
DOOR TO WITHSTAND PRESSURES STATED
N T S
IN PERMIT
INFO BOX ON
SHEET #I. SEE PRODUCT
APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL.
Filled Cell Masonry COlumn With One
45 From Footing To Tie Beam
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Single Filled Cell Column
NTS
Filled Cell Masonry Column With One
45 From Footing To Beam Each.
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Double Filled Cell Column
NTS
Install double filled
cells at door jamb I
girder tie down
Braden It
Braden AIA, PA
Architects
- Planners
41-1
S.E. Coconut Avenue
Tel
(112) 281-8258
Fax
(112) 281-8283
E-mail:
bradenaiaOcomcast.net
Stuart. FL
349% #AAC000032
a
V
y
Er — — — — — — — — — — — — 8— — — — — — — — 8— — — — — ,E
I FI I
I I
4 24
Double cell here for
girder installation above
or
J
o N
O I � �� i
(V
E
E
r
Thicken footing to Thicken footing to
I 24"w x 14"d x 24"L 24"w x 14"d x 24%- FI I
under filled cell under filled cell
under girder bearing. under girder bearing.
I IE
I
°I
�I
I
�I I
IFI ID
o I
I I
H.B.
concrete slab with flbermesh OR I
6"x6" #10/10 WWM on 6 mil Visqueen over7 E
clean compacted termite treated fill `Jim
FII
o
I I
IP
-
F —% f-
N
N
°I
IE
I
° TiiRMITE TREATMENT eciui`
FI
.B.
E
I E
TI
0
4' O"
•I
.... — —
FI r W-4"0 Steel Ballard 1
® I filled w/ Concrete
#I
�1
.J
ICI I I w 55j
°f�z1a I (Koh —IO
U�q
' - =tn
�
I I }+ I
LF
o
I I =L I
rIJ I -SEE I
EE 0
I a o" 1
E M �m\TE
CA
N oOu
______IFS
E i i i E E =_ v0�
I W F5 I
OE
IF4 = � EI p- ��� IE
W x
r
F4 --_ Recess for 0 _�
I�__�__®___
UEL79OE
p
° — _r—�
Garage Door EO EE
o °
o �
1 LI
�iIth concreteVand�(2) #7 barsvVert. tied
into lintels above
Wynne Building Corp.
, 2' Grand Carlton 11
Spanish Lakes
St. Lucie County Florida
FOOTING
SCHEDULE
Mark
Size
Description
PI
14"W
x 14"D
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS
F
12"W
X 12"D
MONOLITHIC FOOTING
WITH (2) #5 BARS CONTINUOUS
30"
x 30" x 16"p
COLUMN FOOTING WITH (4) #5 BARS EACH WAY
8"W
x 8"D
THICKEN SLAB EDGE
WITH 1 #5 BAR CONTINUOUS
F5
14"111
With
x 14"D
Curb at Garage
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS - CURB i
GARAGE
RIGHT
SITTING
ROOM
Date Drawn : Revisions Sheet
8-24-11
Drawn by:
C.C.U.
Checked by:
D.R.B. OF 5
ROOF SHEETING
ATTACHMENT DETAIL
I. Minimum Nail Size = Bid ring shank (min. 2.5" long)
2. Minimum Screw Size = 48 x 2"
3. Minimum Sheathing Thickness 19/32" COX Plywood
4. Use nails or screws bas d on pressure for roof stated
in permit info box on these ans for zone 3
Ke
Area
Edge
Field
Fastener
Pressure
Zone I
6"
61r
Bid ring shank
45 psf
Zone 2
4"
6"
Bid ring shank
% psf
Zone 3
4"
4"
Bid ring shank
84 psf
** Zone 3a
6"
6'r
1#8 wood screw
112.5 psf
** Use nails or screws based on pressure for roof stated
in permit info box on these plans for zone 3
Provide #5 bars with min. 48 bar
diameters overlap Into beam. Tie
filled cell steel into continuous
beam block steel, \-�
Provide Cast -Crete
SUS-OB/OT precast
lintel set in mortar_
Min. 8" Bearing -
Verify with Plan
Concrete'':' 12"x 12"
/Lintel 17- Column Block
#'I
Rebar
Rebar 48 Bar Dia.
Min. Overlap
Column to Lintel 4ttachment
NTS
CBS WALL
Provide #5 bar set in pre -cast
lintel into beam where length of
the opening calls for it.
Provide PT Buck
attached per jamb
stalls into filled ci
4" Pre -cast
Sill \
Filled Cell
Provide #S bars with min. 48 bar
diameters overlap in filled cell. Tie
filled cell steel into continuous
Tooter steel.
Scale: 1/2" = I'—O"
PLY REAR GIRDER TRUSS
Pared Ca
concrete It
luminum Panel
res per marwfacturer
See Tunica[ Stud Detail
1/8" x 3/3Y' Wing Nut m/
appropriate washer and spacing
per manufacturer's Details \
-.Ot3-
IIMIN
��«
Nail 2" x 4" bloekinrg to vert. leg of Stud Detail
truss with IOd x 1.5 Halls at 4" O.C. Poured Concrete or Stud w/ Die Cast Zinc nT8
concrete block well
Nickel Plated Wing Nut
yr
Install Simpson MGT Into wall usingg Concrete Anshan Per g
5/8" dia. threaded rod set min. 12" Manufacturers Space
into wet beam and (22) IOd nails into truss
TRUSS BLOCKING,: DETAIL Flush Mounted Shutter Detail
AT GRIDER STRAPPING nts
AT OUTSIDE WALLS
1/8" thick light textured stucco installed per
ASTM C 926 over ASTM D type 2 paper backed
wire lath nailed to substrate through one layer of
ASTM D Tgpe 2 Felt paper using St nails. Substrate
to T 19/ T 2 F Plywood nailed at nails.
o.c. In Field
and edges with IOd ring shank nails into studs. Aluminum Drip
Edge t Fascia
Gulf Coast Supply and MFG Sv Crimp Metal roofing FL #11451.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max &Pacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails Flash and Counter
spaced L" O.C. at all laps and two staggered rows 12" o.c. in field. Attach flash
deck to trusses using attachment deter on this sheet Nail ledger to
Additional Precast Lintel
tt5 bare -
•.�."ii' �'�• CLEAR
Lintel
Length
Bar
Length
Clear
Span
n u
A
Bars
n u
B
Bars
2'-10"
2'-8"-6"
2,43
none
ia---- / �____r✓
3'-6"
3'-4"
2'-2"
2.43
none
BF8-05/IT BPS-IBAT 8FB-IB/2T
Additional
4'-0"
3'-10"
2'-8"
2,43
none
tt5 bars
ILEA
3'-2"
2A3
none
ti�•�•�: me Row of "H"
Block Above r
5 -4"
5'-2"
4'-0"
2,43
none
S'= 10"
5'-8"
4'-6"
2 #4
none
Precast Lintel
i •%,., Additional ........;, i
2.44
none
#5 bars,
1'-6"
T-O"
6 -2"
2,1;5
none
BPIL-IBAT BFIL-IB/2T
8'-4"
i'-10"
T-O"
2,45
none
Notes:
ALL reinforcing steel is grade 60.
1. min. coverage of steel=l.5"
2. min. bearing required 9 ea, end=8"
3. standard for reinr. steel=ASTM A416
TYPICAL LINTEL SECTION
( PRECAST CONCRETE )
r
LINTEL SCHEDULE
Mark
Window
or D
Unit
Width
Lintel
Size
Cast -Crete
Specification
Rows of
"He Block
Above
Bottom
steel
size
Top
Steel
Size
Max
Gravity
Load
(PLF)
Max
Uplift
Load
(PLF)
Max
Lateral
Load
(PLF)
L22
T-2"
V-L"
BF8-OBAT
1
#5
3069
1569
1024
L31
2'-4'
2'-8"
3'-1"
4'-O"
BF8-OBAT
1
#5
25LI
131.3
11.3
L45
4'-5"
V-10'
8F8-OBAT
I
1 #5
1105
909
339
L50
W-O"
L'-L"
BF8-OBAT
1
#5
1238
835
121
LLO
6'-8"
T-L"
BPS-OB/IT
1
#5
loll
121
534
LBO
W-O"
T-4'
8F8-6/2T
1
#5
2
#5
152
591
512
11_90
T-O"
10'-V
8F8-IB/2T
1
45
2
#5
1.43
530
401
L90B
T-0"
10'-6"
BFI1-I13/2T
ONE
1
#5
2
#5
1533
1183
401
LI00
10'-O"
II'-4"
era-IB/2T
I
#5
2
#5
582
494
452
LIOOB
10'-O"
II'-4"
BFIL-8/2T
ONE
1
#5
1 2
1 #5
1366
1028
452
L120
12'-0"
13'-4'
8F8-IB/2T
1
#5
2
#5
4-11
428
324
L120B
12'-0'
13'-4"
BFIL-I13/2T
ONE
1
#5
2
#5
1015
110
324
LI40
14'-O"
15'-4"
BFIL-I15/21f
ONE
1
#5
2
#5
1250
609
259
L160
IL'-O"
IT-4"
or8-IS/2T
I
tt5
2
#5
300
192
1 194
LILOB
IL'-O"
IT-4"
BFIL-IB/211'
ONE
1
#5
2
#5
950
Soo
1 144
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG I&OR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-0" LONG ARE TO BE PRESTRESSED.
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) IOd x 11/2" nails —
( 24' o.c.) suppporting Max.
18101be. upllft
Aluminum Drip "
Edge t Fascia
2"
2" x L" Sub-Fascl
Kaycan full o vent vinyl soffit installed
ueng 1/8' die shank x 15" long gaiv.
roofing nails with 3/8" die. head per
product approval -see chart sheet #1
12' x 12" concrete column
block filled with concrete
and (2) #1 bare vert. tied__�
into lintel& above
thicken edge to 8"x8"
with concrete and 1
one 45 bar continuous \
BEYOND \
Top of footer
16" below finished floor
4
\ gable end trues
with (2) IOd " ils
at each web \
1/2" think 9-
attached to
framing with
no lea than
on 3/0" hi —rib lath
Dotal and vertical wood
or staples to provide
'4" penetration into
ming and 3/4' penetration
framing members
5/8" thick light textured
stucco on typical concrete
block construction
Varies - see plan
Brace Gable end
with 2" x 4" SYP #2
8ft back nailed to bottom
of top chords using (2) IOd
nails at each truss
IW
QO
tU
Brace Gable end
with 2" x 4" SYP 42 min.
8ft back nailed to bottom
of top chords using (2) IOd
nails at each truss
PRE-ENGINEERED WOOD TRUSSES
® 24"o.c. TYPICAL
( shop drawings by manufacturer )
0
\R-30 blown fiberglass
Q
in bottom chord of trusses
H
—1/2" drywall with smooth finish
LLB
Two rows of beam block filled with concrete
=
—and (1) 45 bar cont. in each row. Substitute
precast lintel Filled with concrete and (1) 45
bar cont. for bottom row over openings
1/2" drgwall over 1" x furringg
PI
strips at 16" o.c. with R4.1 -foil
—insulation on typical 8" Block walls
All drywall to be installed per FBC R102.3.1
and shall meet all pertaining ASTM codes.
Mortar to be Type "M" only proportioned er FBC R601.1
and Mortar joints shall comply with FBC R401.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
Simpson 1-IETA 20
hurricane anchor at each truss
( 24" o.c.) supporting Max.
1810 lbs. uplift ETA 20
P
Fam
.
UW\1 03 1
IN
0
IN
Or
5v crimp metal roof
wooga.
screws with self ecaling washer at
(tutie 2) 30 lb 1alt--un
to %aced (N oicat all In and two staa.T-=MWZ7R_V
to trisses using tachment detail
1
min
Milo
FIII cell with concrete and ROOF FLAN
(1) #5 bar vert. (typicaU.
Max. spacing shall not exceed
48" unless otherwise noted
Base see foundation plan notes for — OVERHANGS AT 1'—O" UNLESS OTHERWISE N
spacing at openings — ROOF PITCH AT -4:12 UNLESS OTHERWISE NC
4" concrete slab with milfibermesh en —
6"xb" an coin WWM to 6 and treated
over TRUSS SHOP DRAWINGS TO BE PROVIDED 1
clean compacted termite treated fill ANY CHANGES TO THIS PLAN SHALL BE S 1.
ARCHITECT FOR APPROVAL IN WRITING PRI
e I=IIII=IIII=IIII- — ALL TRUSS TO TRUSS CONNECTIONS BY
II
I i i i=��I�i i t iIIII-IIII=IIII-IIII III- I, I � I'-
III�-
...,,: .....,...: =IIII 14" FI
Ili ill l�Il=" 3 Tgplcdl Section at Front Forch
#5 bar vert. w/
30" overlap
at each Filled cell
Rear Patio/Slab to
be flush with bottom of
eliding door recess.
Step per foundation plan
Slope per foundation plan 'r
I
Braden t
Braden AIA, PA
Architects
— Planners
411
S.E. Coconut Avenue
Tel
: (112) 287-8258
Fax
: (112) 281-8283
E—mail:
bradenaiaEDcomcast.net
Stuart. FL
34996 ItAAC000032
TRUSS MANUFACTURER
— ARCHITECT TO REVIEW TRUSS SHOP DRAW
TO CONSTRUCTION FOR LAYOUT AND UPLIF
— CONTRACTOR TO PROVIDE FOR FORM BOA
FORM BOARD SURVEY TO TRUSS COMPANY
Wynne Building Corp. Date Drawn
GARAGE 8-24-1-1
2' Grand Carlton if RIGHT Drawn
,
SITTING c.c.u.
Spanish Lakes ROOM Checked by
St. Lucie County Florida D.R.B.
PA
I-- °A„
Poles
SR
Load
Wire
Description
cmc#
cmc#
Description
Wire
Load
BR
Poles
2
40
1.0 kw
#8
A/C comp
1
2
AHU
#10
3.5
kw
30
2
3
4
2
30
4.5 kw
#lo
40 gal. water HTR
5
4
Range
#6
12.0
kw
50
2
�
8
20
1.8 kw
912
Pump
9
10
Dryer
#10
5.0
kw
30
2
II
12
1
20
1.5 kw
#12
13
14
Dishwasher
#12
1.2
kw
20
1
1
20
1.5 kw
#12
Microwave
is
IL
Refrigerator
#12
L2
kw
20
1
1
20
1.5 kw
#12
Kitchen S.A.C.
Il
18
Recepts
#12
20
1
I
20
1.5 kw
tt12
Kitchen S.A.C.
19
20
Recepts
#12
20
1
1
20
1.2 kw
412
Clothes Washer
21
22
Recepts
#12
20
1
1
20
0.81 kw
#12
Garage Door Opener
23
24
Recepts
#12
20
1
1
20
1.4 kw
#12
25
24
Recepts
#12
20
1
1
20
1.92 kw
#12
21
28
Recepts
#12
-
20
1
1
20
#12
General Lighting
29
30
Recepts
#12
20
1
1
20
#12
General Lighting
3l
32
Recepts
#12
20
1
1
20
#12
General Lighting
33
34
Exterior GFCI
#12
20
1
1
20
#12
General Lighting
35
36
Bathroom GFI
912
-
20
1
20
#12
Smoke Detectors
3l
38
General Lighting
#12
20
1
20
#12
Bathroom GFI
39
40
General Lighting
#12
-
20
I
spare
1 41
1 42
1 spare
PANEL
"A" LOAD CALCULATION
SHEET
Load Description
Qt .
Watts
Total(Watts)
General Lighting (3 watts sq. ft)
Small. ,Ap. hance C.ircuit(s)................... .
Range _......... ...............................................
Refrigerator ....................................
Microwave
.................................................................
Dish. Washer „ . . . . . . . . . . .. .
. ..........
Clothes.Washer...............................................
Clothes„Dryer................................................
Water Heater
Water, .Pump ..................................................
.Garage Door. Opener . .. .. . I ...............
.............
..............
....
.......
1135
3
5,205
2
1,500
3,000
1
12,000
12,000
1
1,200
1,200
1
1,500
1,500
1
1,200
1,200
1
11200
1,200
1
5,000
5,000
1
4,500
4,500
1
1,800
1,800
1
810
810
Total
Watts
31,415
First 10000 Watts
e100%
1
10,000
10,000
Remainder
21,415 e40%
1
O
10,964
Electric Heat or A/C 10,000 e65%
1
10,000
10,000
Calculated Load
Watts
30,966
Calculated Wattage Divided by Voltage =
Voltage
Total Amps
Panel Size Required =
240
129.03
150 Amps
Electrical S mbol Leend
S
Single Pole Switch
®
Recessed Can Light
S3
Double Pole Switch
®
Eyeball Recessed
PB
Push Button Switch
Exhaust Fan
Duplex Outlet
Ceiling Mounted Light
Special Receptacle
O-
Wall Mounted Light
=49
Waterproof ground fault circuit
Light with Pull Chain (attic)
®
Floor Duplex Outlet
©
Computer Connection Jack
Fc-m-1
Carbon Monoxide Detector
V
Flood Light
Q
Thermostat
®
Electrical Panel
©
Central Vac
r=i
Electrical Meter
Smoke Detector
Ceiling fan
Television Jack
r;;
Telephone Jack
^sc
A/C Disconnect
1 x 4 Florescent Light
®
2 x 4 Florescent Light
Speaker Hook -Up
I❑
Intercom
®= JUNCTION BOX TO SUPPORT A FAN
O = THERMOSTAT LOCATION
B/A = BALANCED AIR
Electric Notes:
I. Use copper wire only, no aluminum.
2. Provide and wire all required smoke detectors.
3. Contractor to verifg location of electrical
service and provider.
4. ALL paddle fans shall be on a rheostat.
S. ALL bath and kitchen receptacles to be GFI protected.
6. ALL exterior outlets to be WP/GFI protected.
1. Recessed cans to be installed per NFPA requirements.
8. AFCI receptacles are required in all rooms except
Kitchen, Bathrooms, and Garage.
9. A/C Return Air Balance Must comply w/ FBC RM1602
10. A/C Refrigerant lines that are run thru slabs must be
sleeved in PVC
II. ALL A/C Equipment shall comply with energg calculation
12. All work shall be performed bg a licensed electrical
contractor, the completed sgstem shall be fulIg operative.
13. Contractor shall pag for all fees, permits, testing, and
inspections including blower testing where required.
14. All work shall be coordinated with other trades to avoid
interference with the progress of construction.
15. All required insurance shall be provided for protection
against the public liability and property damage for the
duration of the work.
16. Contractor shall guarantee all materials and workmanship
free of defects for a period of not less than two gears from
the date of acceptance or certificate of occupancg, or one
year from closing sale of house.
Correction of defects shall be completed without additional
charge and shall include replacements or repair of any
other phase of installation that may have been damaged.
H.B'4-
Vent -thru---
Soffit
140 CFM
12x8x1
SITTING ROOM
165 CFM 12xl2x9
12x8x-1 B/A
ra
® �r r
I I
M TER
BE ROOM
GR AT
RgOM
140 CFM
12x8x1
12x12x9
B/A i
158 CFM Center Registers r a
on ceiling fan 158 CFM I ---- ----- a I
IOXIOxI I OxIOXI d� r - - - d12
( ® 12e A
DINING
ROOM
- A
12" ----
i
✓ I0
io°
K
128 CFM
1 12xl2x1
y I-411
I �7t1
1 1
171 I
I
I
1
131 CFM
I
I
I
i
12x6x1
I
L�-
I
SECOND
I
BEDROOM
12xl2x8
I
1 i l
l�J
= THERMOSTAT LOCATION O
11 55 SifM
�� _ ____Vent_thru
BAT Soffit
A/C
W 4"� _Steal Ballard # 1
7 I In"
(�, Attic Access
rr< = I with light - J
Q Q I L
1� \ _ JI
1- �z: 150 Amp
' Panel Meter
COVERED
PORCH
MECH?,V'CAL LAYOUT
SCALE: 1/4" = I'-0"
11. It is not the intent of these plans to show every minor detail
of construction. The contractor shall furnish and install
all items for a complete electrical system and provide all
the requirements necessarg for the equipment to be placed in
proper working order.
18. All work shall be done in accordance with the N.E.C. and
shall comply with all local codes and ordinances, and shall
meet all standard requirements of the local electric utility
and telephone company.
19. The electrical sgstem shall be completelg and effectively
grounded as required bg the latest edition of the N.E.C.
20. All material shall be new and shall bear underwriters'
labels where applicable.
21. All equipment and panel sizes shall be verified before
ordering. The contractor shall provide circuit routings to
suit the job conditions.
22. Furnish and install all fixtures as called for on the plans
or as selected by others.
23. All raceways and pipes placed in or through ang concrete
slab shall be spaced a minimum of three diameters of the
largest conduit or pipe from any other service.
24. All exposed wire below 9'-1" shall be installed in metal EMT
conduit.
25. Dryer Vents to be installed per FBC RM1502
GARAGE
r----------------- 1
I I
I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
A/C disc.
150
#2/0 Aluminum feed
AMP
I '/a' Conduit PCB
A EL
M T£
AHU
2" PVC
2" rigid service FPL Bareto #4 coppt. er
a slab
ELECTRICAL RISER
- Contractor shall use AL-CU Landing lugs. NTS
- Contractor shall torque lugs I.A.W.
manufacturers recommendations which
shall be verified prior to construction
Braden It
Braden AIIA, FA
Architects
- Planners
411
S.E. Coconut Avenue
Tel
: (112) 28-1=8258
Fax
: (112) 281=8283
E-mail:
bradenaias'comcast.net
Stuart_ FL
34996 UAAC000032
Exhaust Duct
Thru Soffit
Wire For
Front Post
Light
Exhaust
Thru Sc
4" Exhaust
Duct Thru
Wall
p. GFI
Install dull
� under die
Q not shown f
clan
ELECTF�:)fC,4L PL,4N
SCALE: 1/4" = 1'
o Post Light with
�a Photo cell
EU
Attic ventinq Calculations FBC 2304
�U
a°
o °W Total Attic Space = 212.4 sq. ft.
Venting Ratio 1/150 = 14.1(o sq. ft. required
o�
Frovlde A Continuous Vented Soffit
u_
Wynne Building Corp.
�2' Grand Carlton
Spanish Lakes
St. Lucie County Florida
Date Drawn : Revisions Sheet Comr
GARAGE s-24-11
f f RIGHT Drawn bg:
SITTING C.C.u. -� 12-
Room Checked bg:
D.R.B. OF 5
=LIFE SAFETY WARNING
as
Thi symbol identifies Life Safety Warnings that should be read
give special attention by all persons installing trusses.
SPACING NOTE
ALL TRUSSES ARE TO BE SET
AT 2'-0: ON CENTER
EXCEPT AS NOTED
MULTIPLE PLY TRUSSES MUST BE
,TENED TOGETHER PER ENGINEERIN(
BEFORE SETTING. REFER TO
GINEERING DRAWING TO DETERMINE
IF MULTIPLE PLY. A
F 1
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
Span or less A 30' to 60' Span
f6o degrees Spree er Bar
\\ or less
_ 2 ka9 — _Approx 2/3 to_*.
To ine span approx. e /2 of Span
REFER TO BCSI REFER TBCSI
Truss u,t be set tnls way it crane used. Truss must be set this way if crane used.
sxompie, yo,e trc s moy not march. This is an example, truss may not match.
Truss
nest on
operator sets truss this wayinsist crane operator sets truss this way.
All load bearing walls, headers,
beams & lintels must be in place
at indicated height before trusses
A are installed. A
.fR HAN�1—�R NCYTE
UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE l RUSSES
ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR
ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT
WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS.
CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR.
U REPRESENTS A HANGER
Carrying Girder
For Truss to Truss
Connections see
hanger/connectorTNailsbe es
de tabs o
chedule in engineeringenails.
package.
EAT PLATES BY CHAMBERS
INDICATES LOAD BEARING WALL
j REQUIRED BY TRUSSES
SUPPLIED BY BUILDER
AT A HEIGHT OF 8'-l"
ABOVE FINISHED FLOOR
ARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER
BAR OF
17' - 23' IN LENGTH
Do not stand on trusses until
they are braced per BCSI &
properly
nailed to
straps &
hangers
upset=l/4" heel=3 15/16"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 8'-l"
TYPICAL END DETAIL
12
4.00 17
12 2.001
Sh
upset=l/4" heel=315116"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 8'-1"
END DETAIL: A
IMPORTANT NOTES:
* ALL BEAMS ARE BY THE BUILDER.
* LEVEL RETURNS ARE BY THE BUILDER IF DESIRED.
a
FABRICATION AGREEMENT'
'MUMO sCANNOTNOTARMLWMTMA011bOrrONellmaRETUIW®
TRs IWd dssvlpton dtr pnprlytdam tla buaaswe a Iailsd k
t.:Tmesem ela be mob In all P amatm Mh this base b dal �
;t�hlstoodessAh0*�►dttaaahit.aloam umbtb.olndh.tnasn
ZNdmanabnshtliYyaRhwabsenvMUedbyfMu 8ml
'• .S. IAtsia aaelon rtdleo b gaAdad by gatrod Dist b Chrrtbra Tnm elltdn Ien (10
.i� of �eetlas b M t4 C11 a Tmp 4W Q1 Mliw days h MYd
non my b to Jab else. It Ie tta awe' b
E. visa p doaal bl PaaR l 7 babelIe aele b fir n NEW dtntpw am., IN h
�alqut Ai60wkwfnixoAdonamgadtelYbhrChambers hwa
7: Tti• b a PURCHASE OROM to Clrlaers,Tw a f,. apnld.Read a or r d
Matt a reasarial pica Woks are be mods an �� i Myr�'osrcw�l aof no
t derery. knacks tMy. be made at sdn&ibd dab"bt
aeal of fibdmud lames. Tho udaalpad sQsaa b payChembere.Ttuas maaaMhb
wfor cooscmm add sum ran Iem nods ,•V2 7i PK h !Mdp
L SlpnM or hoar styotem anti dad constIo s alitaanrtt b all Iona hill
P to aenslderstbn of Chambers Trim airtdtng asm,a hls naI ' its udadQal
toatNbrrly graranWs payara adan due d ww wild d Yddfsdneas owed I
+tintbera Trim bY.a+Y ntelerlsl srd to ttrtdrslRad'psss bpry eud
dd.bleepdnan btduft ee. It dal"h Paymra tm tar tta- W be de M Ih
Yb. bl to "" of ay N;xgm mtoMlitp tli gsrmrk, so tems tmiAed breadq
payndri marred to hismil o a prg" sum tad too 100 wale brary rwh sca wl
18a1i1 boob Carry. Fills
1,. ra,wdloe 'r uehlu.kto a sae Rommmend�oted.rw on
GATED '�1V,
N13NED '
FCIR tm r •-.• _ .
fYtulfiple ply trusses must be fastened together per erlglrNradng
befols they an all fafiure to do so can result -in roof cdlapga
Temporary erlN parmartenit brigs lg an reglded and an am fill
and property and Is the reaponslbUtty of the thus erector:
Study the contends of the brWn;d= pacitst included on defiwr
before "itling 1rlusits. .
.'Mrmnawtbantrrdbacodp�dee4lbPreuNtit�lelladarr+pe
Tnueea must be set plumb and sgwre
Do not set bunks or stack of plywood! Ill matergli or shy
_
D&N0TSETTRU35ES usInv inn* LJ%Tvva
USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
..1000
3105 oleander Avenue
Fort Pler * Florida 34982.6423
800-551-6932
Fort pierce 7n-"5-M12 Eel 77`1�86-8711
vim... n erh 772JUM4012 Shari 'ir1.268-3302
92.0/93.2 MTEK 4.2
---
—�
DESIGN CRITERIA
County
SAINT LUCIE
Building Department
SAINT LUCIE COUNTY
Wind Design Criteria
ASCE 7-2014
is
I
Wind Design Method
Main Wind Force Resist
Roofing Material
Shingle or Shake
Loading in PSF
Roof R.D.L.
°
I
Top Chord Live
20
Top Chord Dead
7 4.2
° '
Bottom Chord Live
10 Non -Concurrent
w I°
n O
Bottom Chord Dead
10 3
w
'
TOTAL Load
37 7.2
Duration Factor
1.25
a
Wind Speed
165mph
3
Top Chord C.B.
Sheeting by builder.
v
Bottom Chord C.B.
Sheeting by builder.
Highest Mean Height
14'-W
Building Type
ENCLOSED
Building Category
II:Non Restrictive
Exposure Category
C
Barrier Island
No
Conforms to FBC 2014
GARAGE RIGHT
13 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT
Verify DESIGN CRITERIA shown above with the
building department and your engineer. '
Design Criteria is the responsibility of the
Chambers Truss Inc. Drawing Name: M11319
Scale: 1 /4 = 1'
73 total trusses, 13 different trusses.
MI 4: SAE ACAD: SAE Reviewed
Date:02/28/12 Revised:10/07115
FOR
WYNNE BUILDING CORP.
DESCRIPTION:
62' GRAND CARLTON II W/ SITTINC
or
62' GRAND CARLTON III W/ SITTIM
PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE 71