Loading...
HomeMy WebLinkAboutFlorida Energy effeciency!-7�OR405-2014 IDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE ROYALE Builder Name: WYNNE Street: WYNNE DEV. Permit Office: ST.LUCIE COUNTY City,State,Zip: FT. PIERCE,FL, N Permit Number: Owner: 6 y ������ S Jurisdiction: Design Location: FL,Fort Pierce County:: ST.LUCIE COUNTY(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1688.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul, Exterior R=4.1 1448.70 ft2 b.Frame-Wood,Adjacent R=11.0 240.00 ft2 3. Number of units, if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1720.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1720.00 ft2 6. Conditioned floor area above grade(ft2) 1720 b. N/A R= ft2 Conditioned floor area below grade(ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(155.4 sqft.) Description Area a.Sup:Attic, Ret:Attic,AH:Attic 6 325 a. U-Factor: Sgl, U=0.54 115.42 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a.Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.316 ft. Area Weighted Average SHGC: 0.250 14.Hot water systems 8. Floor Types (1720.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.970 a.Slab-On-Grade Ede Insulation g t R=0.0 1720.00 ft2 b. Conservation features b.N/A R= ft2 None C.,N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.090 Total Proposed Modified Loads: 54.94 PASS Total Baseline Loads: 56.22 I hereby certify that the plans and specifications covered by Review of the plans and O,THE Srg?� this calculation are in compliance with the Florida Energy specifications covered by this y _ O� Code. calculation indicates compliance yk�`ii '%� '_' �o�� vo with the Florida Energy Code. �O PREPARE B. ' Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 * �' I hereby certify that this building, as designed, is in compliance Florida Statutes. 5� with the Florida Energy Code. G'OD WE OWNEREN BUILDING OFFICIAL: DATE: DATE: i - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -.Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. C01MI 4/3/2017 3:41 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 I M R405-2014 PROJECT Title: WYNNE THE ROYALE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1720 Lot# Owner: Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE Rotate Angle: 135 Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: ST.LUCIE COUNTY Jurisdiction: Whole House Fan: No City,State,Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE I / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL_VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1720 13760 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 343 2744 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M. BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 172 1376 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 98 784 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 528 4224 No 0 1 Yes Yes Yes 10 BEDROOM 3 169 1352 No 1 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio BEDROOM 52 ft 0 343 ftz ---- 0 1 0 2SIab-On-Grade Edge Insulatio WIC 1 ft 0 63 ftZ ---- 0 1 0 3 Slab-On-Grade Edge Insulatio M.BATH 8 ft 0 56 ftZ ---- 0 1 0 4 Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 172 ftz ---- 0 1 0 i i 5 Slab-On-Grade Edge Insulatio BATH 5 ft 0 45 ftz ---- 0 1 0 6 Slab-On-Grade Edge Insulatio BEDROOM 2 42.6 ft 0 204 ftZ __-- 0 1 0 7 Slab-On-Grade Edge Insulatio ENTRY 6.3 ft 0 98 ft2 _--- 0 1 0 4/3/2017 3:41 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 I S 1. FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab-On-Grade Edge Insulatio LAUNDRY Eft 0 42 ft2 ---- 0 1 0 9 Slab-On-Grade Edge Insulatio GREAT/DINING 48 ft 0 528 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio BEDROOM 3 13 ft 0 169 ft2 ---- 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1813 ft2 286 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1720 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) BEDROOM 30 Blown 343 ft2 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic(Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic(Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood 5 Under Attic(Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic(Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic(Vented) ENTRY 30 Blown 98 ft2 0.1 Wood 8 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic(Vented) GREAT/DINING 30 Blown 528 ft2 0.1 Wood 10 Under Attic(Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood WALLS Adjacent Space Cav ity Width Height Sheathing Framing Solar Below ()Ent In Wall Type0 1 N=>SE Exterior Concrete Block-Ext InsilHEDROOM 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 2 S=>NW Exterior Concrete Block-Ext InsiHEDROOM 4".1 29 0 8 0 232.0 ft2 0 0 0.5 0 3 W=>NE Exterior Concrete Block-Ext InsfEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 4 S=>NW Exterior Concrete Block-Ext InsuM.BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 5 N=>SE Exterior Concrete Block-Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 6 N=>SE Exterior Concrete Block-Ext InfiffDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.5' 0 7 NE=>S Exterior Concrete Block-Ext InQEDROOM 2 4.1 2 10 8 0 22.7 ft2 0 0 0.5'� 0 8 E=>SW Exterior Concrete Block-Ext InQEDROOM 2 4.1 9 0 8 0 72.0 ft2 0 0 0.5, 0 9 SE=>W Exterior Concrete Block-Ext InQEDROOM 2 4.1 2 10 8 0 22.7 ft2 0 0 0.5i 0 10 S=>NW Exterior Concrete Block-Ext IndIffDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 11 NE=>S Exterior Concrete Block-Ext Insul ENTRY 4.1 1 5 8 0 11.3 ft2 0 0 0.5 0 12 E=>SW Exterior Concrete Block-Ext Insul ENTRY 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 4/3/2017 3:41 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 i I s :v FORM R405-2014 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 13 S=>NW Exterior Concrete Block-Ext InsLUAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0 14 N=>SE Exterior Concrete Block-Ext InsGREAT/DINT 4.1 28 0 8 0 224.0 ft2 0 0 0.5 0 15 W=>NE Exterior Concrete Block-Ext Ins3REAT/DINT 4.1 20 0 8 0 160.0 ft2 0 0 0.5 0 16 N=>SE Exterior Concrete Block-Ext InRffDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 17 N=>SE Garage Frame-Wood BEDROOM 3 11 30 8 240.0 ft2 0.23 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E=>SW Insulated ENTRY None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V/ # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 W=>NE 3 Metal Low-E Single Yes 0.54 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 S=>NW 4 Metal Low-E Single Yes 0.54 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 E=>SW 8 Metal Low-E Single Yes 0.54 0.25 23.2 ft2 1 ft 0 in 1 ft 4 in None None 4 N=>SE 14 Metal Low-E Single Yes 0.54 0.25 36.8 ft2 1 ft 0 in 1 ft 4 in None None 5 W=>NE 15 Metal Low-E Single Yes 0.55 0.25 40.0 ft2 10 ft 0 in 1 ft 4 in None None 6 N=>SE 16 Metal Low-E Single Yes 0.54 0.25 16.2 ft2 1 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 300 ft2 300 ft2 30 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1605.3 88.13 165.74 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 4/3/2017 3:41 PM 'EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 I FORM R405-2014 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftZ DUCTS ---Supply-- —Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 325 ftZ Attic 85 ftZ Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar Apr May ri Jun X Jul X Aug Se [ ]Oct Nov Dec Heatin HJan H Feb Mar Apr May Jun Jul Aui Sep [ ]Oct XNov Dec Ventin Jan Feb HX Mar [X)Apr [ May Jun [ Jul Aug Se [X]]Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 I i 4/3/2017 3:41 PM ,EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 i FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE ROYALE Builder Name: WYNNE Street: WYNNE DEV. Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be airtight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 4/3/2017 3:41 PM EnergyGauge@)USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 - hftPro ecSumma Job: wrgso Date:CEnt re House a QUICK CALCS, INC. 317 ST.'LUCIE LN FT PIERCE,FL 34946 Phone:772-466-6799 Fax 772466-6796 Email:QUICKCALC8WL.00M Project Information For: THE ROYALE WYNNE DEV., FT. PIERCE, FL Notes: Design In • • Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db g0. °F Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L - Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing , Structure 19898 Btuh Structure 18607 Btuh Ducts 6092 Btuh Ducts 9204 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0: Btuh none Humidification 0 Btuh Blower e) 0 Btuh. Piping 0 Btuh Equipment load 25990 Btuh Use manufacturer's data n Rate/swingg multipplier 0.95 Infiltration Equipment sensible load 26420 Btuh Method Simplified' Latent Cooling Equipment-Load Sizing Construction quality Average Fireplaces 0 Structure 2182 Btuh Ducts 2516 Btuh Central vent(0 cfm) 0 Btuh Heating Coolingg' (none). . Area(ftz) 1720 17221 Equipment latent load 4697 Btuh Volume(fta) 14231 14231 Air changes/hour 0.38 0.20 Equipment total load 31117 Btuh Equiv.AVF(cfm) 90 47 Req. total capacity at 0.70 SHR 3.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 Cond 25HBC536A*030 AHRI ref . 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 24360- Btuh Heating output 34600 Btuh @ 47'F Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual air flow 1160 cfm Actual airflow. 1160. cfm. Air flow factor 0.045 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0.50 it H2O Static pressure 0.50 in H2O 1 Space thermostat Load sensible heat ratio 0.86 Capacity balance point=35 OF Backup: Input=7 kW,.'Output=23009 Btuh, 100 AFUE jrp Calculations approved byACCA to meet all requirements of Manual J 8thn - wrightsofte 201 -Apr:17' 017:29:34 Right-Suite®Universal 201717.0.14 RSU08101 Pa'e 1 ..Muick CalcslDocuments\WYNNE-ROYALE-REVISED.rup Calc=MA Front Door faces: N 9 _rF wrightsoft, Right-J®Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email;QUICKCALCS@AOL.COM 1 Room name Entire House BEDROOM 2 Btposed wall 180.9 ft 52.0 ft 3 Room height 8.3 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 343.0 ft 5 Room area 1719.5 ft' 343.0 ft' Ty Construction Ll-value Or HTM Area (ft2) Load number (Btuh/ft'°F) (Btuh/ft2) or perimeter (ft) (Btuh) orsperimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 13A-4ocs 0.143 h -4.00 2.55 577 524 2096 1333 72 72 288 183 1A-clom 1.270 n 35:56 34.77 16 0 565 553 0 0 0 0 4A5-2om 0.770 n 21.56. 19.31. 38 0 815 730 0 0 0 0 W 13AAocs. 0.143 ne 4.00 2.55 34 34 136 86 0 0. 0 0 11 13A-4ocs 0.143 a 4.00 2.55 112 67 269 171 0 0 0 0. ! clorn 1.270 a 35.56 87:29 24 3 848 -2082 0 0 :0 _ 0 11130 0:390. e:' 10.92 11.31 21 21 229 -238 0 0 0 0 W 13AAocs 0.143 se 4.00 2.55 23 23 91 58 0 0 0 0 V�/ 13A flocs:' - 0.143 's 4.00 .2.55 _ 456 ` 449 1798 1143 :232; 232. -929 591 1---G 1Ac1om 1.270 s 35:56. . 34.77 ..7 14 247 241 0 0:'. 0 b. 13A-4ocs 0.143 w 4.00 2.55 290 217 867 551 112 79 318 202 I--G 1A-clom 1.270 .w 35.56 55.25 33 4 1162 1806 33 2 1162 1806 4A5.2om 0.770 w 21.56 45.63 41 4 880 1862 0 0 0 0 :P 12C-Osw.... . 0.091 :2.65 1:28; - 224. 224 . ..;,571 . . :287 : 0...: 0 - 0` 0 C 16A-30md 0.032 - 0.90 2.32 1720 1720 1541 3989 343 343 307 796 F.:..'; .22A-1pl 0.989.. - 27.69 0.00 : 1720 181 5010 0 343 52 1440 0 6 c)AED excursion 465 668 Envelope loss/gain 17124 15595 4444 4245 12 a) Infiltration 2774 782 773 218 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 2000 0 Subtotal(lines 6 to 13) 19898 18607 5218 4463 Less extemal load 0 0 0 i 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 19898 18607 5218 4463 15 Duct loads 31% 49% 6092 9204 31% 49% 1598 2208 Total room load 259901 278101 6815 6671 Air required(cfm) 1 11601 11601 1 1 3041 278 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .` Aj- wrightsoft- 2017-Apr-1017:29:34 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1 .•.\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc=MJ8 Front Door faces: N . wrilghtsoft' Right�J®Worksheet Job: Entire House Date: QUICK CALCS;INC. By: 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@,AOL.COM 1 Room name WIC M.BATH 2 Exposed wall 0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 9.0 ft 7.0 x 8.0 ft 5 Room area 63.0 ft2 56.0 ft2 TY Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/f?�•°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om .1.270 n 35.56 34.77 0 0 0 0 0 0. 0 0 4A5-2om 0.770 n 21:56 19.31 0 0 0 0 0 0 0 0 W 13AAocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 13AAocs 0.143 e . 4.00 2:55 0 0 0 0 0 0 0 0 1A-c1om• '1i270 e- 35.56 : 87.29 0 0 0 0 0 0. A. 0 11D0 '; 0390 e: 1092 11i31 0 0 0 . 0 0 0 0 . 0 W 13AAocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 13A-flocs. 0143 -.s- 4 00 2.55:' 0 0 0 0 ,64 57 228 :'•145 ,1Ac1om 1:270 : s 35.56: 34.77 0 0. 0 0 7 7 247 241 L----G 13AAocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P': 12C-0sw;. '0.091 - 2.55_ - 1.28 0 0 _ 0 0 _ 0 0 0 0 C 16A 30md 0.032 - 0.90 2.32 63 63 66 146 56 56 50 130 F.: 22AAPI 0.989 - = 2Z.69 0.00 63 0 0 ,0 56 8 222- 0 6 c)AED excursion -10 -39 Envelope loss/gain 56 136 747 477 12 a) Infiltration 0 0 119 34 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 56 136 866 �511 Less exdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 136 866 511 151 Duct loads 1 31% 49% 17 67 31% 49% 265 253 Total room load 74 203 1 1 1131 764 Air required(cfm) 3 8 50 32 Calculations approved byAC•CA to meet all requirements of Manual J 8th Ed. wrightsoft' 2017-Apr-1017:29:34 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2 ...\Quick CalcsfDocumentslWYNNE-ROYALE-REVISED.rup Calc=MJ8 Front Door faces: N 1-wrightsoft• RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name KrrCHEN BATH 3 �sed l m height 8.0 ft Oft heat/cool 8.0 ft 5.0 ft heat/cool 4 Room dimensions 1.0 x 172.0 ft 9.0 x 5.0 ft 5 Room area 172.0 ft2 45.0 W Ty Construction U-value Or HTM Area number (Btuh/ftk-°F) (Btuh/ft') or perimeter (ft) (Btuh) ors perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VL213A4ocs 0.143 n. 4.00 255 0 0 0 0 40 40 160 102 IA-clom 1:270 n 35:56 34.77 0 0 0 0 0 0. 0 0 4A5-2om 0.770 : n 21:56. 19.31 0 0 0 0 0 0 0 . 0 W 13A-4ocs. 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 . 13A•4ocs 0.143 a 4.00 -2:55 0 0 0" 0 0 0 .0 0 �-G 1Y1clom 1.270 .e 35.56 87.29 0 0 0 0 0 0 0: .0 D 11D0 0 390 :,e '- 10.92 . ..11.31 0 0 0 .0 0 p . p :. p W 13AAocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 w 13A-4ocs .0:143 s: 4.00'. 2,55 - '0 0 .'0-. 0 0 0- :0 `0 .'�: G '%c1om... 1.270-' s 35:56.C 34.77' 0 0 p p 0- 0 0 0 13A-4ocs 0.143 w 4.06 2.55 0 0 6 0 0 0, 0 0 1A-c1om 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0 �--G 4A5.2om O.T70 w 21.56 45.63 0 0 0 0 0 0 0 0 12C-0swr 0.091_ .. -:.. :5$:?:.- -1:28 64'. 64 163 82 0 0: p 0: c 16A30md 0.032 0.90. 2.32 172 172 154 399 45 45 40 104 T 22A+tpl 0.989 27.69 0.00 172 -0 0 0 '0 6 c)AED excursion -176 -16 Envelope loss/gain 317 305 339 190 12 a) Infiltration . 0 0 74 21 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2000 .0 Subtotal(lines 6 to,13) 317 2305 413 211 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 317 2305 413 211 15 Duct loads 1 31% 49% 97 1140 31% 490/c 127 104 Total room load 414 3446 1 540 315 Air required(cfm) I 1 1 18 144 24 13 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrights®ft" Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Apr-10 1AEMN Page 3 ..\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc=MJB Front Door faces: N -wrightsoft- Right-J®Worksheet Job: Entire House Date: QUICK CALCS, INC. By 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@>OL,COM 1 Room name BEDROOM 2 ENTRY 2 .E)posed'wall 42.6 ft 6.3 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 204.0 ft 1.0, x 97.5 ft 5 Room area 204.0 ft2 97.5 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area t) Load number (Btuh/W-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 13A4ocs 0.143 n 4.00 255 112 112 448 285 0 0 0 0 1A-06m 1:270 n - 35.56 34.77 0 " 0 0 .0 0 0 0 0 4A5-2om 0.770 n 21.56 19.31 0 0 0. 0 0 0 0: 0 W 13A4ocs- 0.143 ne 4.00 2.55 23 23 91 58 11 11 45 29 11 _ 13A4ocs 0.143 .e 4.00 255 - .72 48 193 123 40 19 -76 48 1Ac1om,: -1:270 e: 35.56 87:29 24 2 848., .2082 0 0- 0 ` .0 110,0 0.396 'e 16.92 11.31:. 0 .. 0 - 0 0 21 21 220 . 1238 W 13A-4ocs 0.143 se 4.00 2.55 23 23 91 58 0 0 0 0 W 13A4ocs; 0;143 s= 400 2.55 112 112:" 448 285: 0 0 0 0 �-G :1A-c1om 1.270 s 35SR 34.77 0 0 0. 0 0 : 0 0 0 Tj13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1A-c1om 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 `12"sw, 0:091 2:55 1.28 0 0 0,: -0 104 104 265 133 C 16A-30md 0.032 - 0.90 2.32 204 204 183 473 98 98 87 226 F' 22A-tpl. 0:989':.- 27.69 :0.00 - 204 43 1119 0 98 6 r. 175 0 6 c)AED exursion -90 -50 Envelope loss/gain 3481 3273 878 625 12 a) Infiltration 634 179 95 27 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 4115 3452 974 651 Less external load 0 0 0 0 Less transfer 0 0 0 : 0 Redistribution 0 0 0 0 14 Subtotal 4115 3452 974 651 15 Duct loads 31% 49% 1260 1708 31% 49% 298 322 Total roam load 5376 5159 1272 974 Air required(cfm) 2340 2195 57 41 Calculations approved byACCA to meet all requirements of Manual.J 8th Ed. wcightsoft' 2017-Apr=10 1 Right-Suite@ Universal 2017 17.0.14 RSU08101 Page 4 ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc=MJ8 Front Door faces: N - -wrightsoft Right-M Worksheet Job: • Entire House Date: QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@,AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 Exposed wall 6.0 ft 48.0 ft 3 Room height 8.0 ft heat/cool 8.9 ft heat/cool 4 Room dimensions 7.0 x 6.0 ft 1.0 x 528.0 ft 5 Room area 42.0 ftz 528.0 ft' Ty Construction U-value Or HTM Area (ft-) Load Area Load number (Btuh/ft2°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13AAocs 0.143 n 4.00. 2.55 0 0 0 0 249 211 846 538 9A-clom 1:270 n 35.56 34.77 " 0 0 0 0 0 0 0 0 4A5-2om 0.770 : n 21:56 19.31 0 0 0 0 38 0 815 730 W 13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 13A-0ocs 0:143 a 4.00 2.55 0 0 0 0 0 0 0 0 1Aclonn .1.270 .e 35.56 87.29 .0 0. 0.. 0 0 0. 0 0 11D0 :. 0.390 ,e- 10.92` -,.11.31 0 0 0 . 0 -0 0. 0 0, W 13A-4ocs 0.143 se 4.00. 2.55 0 0 0 0 0 0 0 0 yV�/I 13A�ocs;.. 0143 s.. 4.00 2:55 48 48 192 122 0 0 r -0 0. �G ,1A�1orri ' 1:270 s 35.56. 34:77 0 0 0 0 0` .0 p 0 W 13AAocs 0.143 w 4.00 2.55 0 0 0 0 178 137 549 349 I�-CG 1A-clom 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56 45.63 0 0 0 0 41 2 880 1862 P .12C-0sw::• . : . 0.091..._ :2.55:: 1.28;• 56 56 - : 143 72 °0 0 : 0 0- C 16A30md 0.032 0.90 2.32 42 42 38 97 528 528 473 1225 F 22A tpl �0 989 27d69 0.00 42 .6. - -166' -0 528 48:' 1329 0 6 c)AED excursion -22 -305 Envelope loss/gain 539 269 4893 5008 12 a) Infiltration 89 25 794 224 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 628 294 5687 5232 Less extemal load 0 0 0 0 Less.transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 628 294 5687 5232 151 Duct loads 311/,1 490/( 192 w 31% 49% 1741 2588 Total room load 820 440 7428 7821 Air required(cfm) 37 18 332 326 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .� 441- wrightse ft 2017-Apr-1017:29:34 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 5 ...%Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc=MJ8 Front Door faces: N - -viwrightsoft° Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS(tAOL.COM 1 Room name BEDROOM 3 2 Fgosed wall 13.0 ft 3 Room height 8.0 ft heat/cool 4 Room dimensions 13.0 x 13.0 ft 5 Room area 169.0 ftz Ty Construction Ll-value Or HTM Area (ft') Load Area Load number (Btuh/ftz°F) (Btuh/ft2) or 'perimeter ft( ) (Btuh) or perimeter Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.55 104 88 353 224 1Ac1om 1.270 n - 35.56 34.77 16 0 565 553 4A5.2om 0.770 n 21.56. 19.31 .0 0 0 0 W 13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 11 V 13A-0ocs 0:143 .e 4.00 2.55 0 0 0 0 ��/--G 1Ac1om 1:270 a 35.56' .87,29 0 0 0 0 �D. 11D0 0.390 a 10:92 11.31 0 0 0 0 W 13A4ws 0.143 se 4.00 2.55 0 0 0 0 yJ 131N-0ocs. :0:143 s; 4:00-. 2.55 0 0 p L-- G 1A-clorri 1.270 :.'s 35:56 34.77 0 0 0- 0 V)/ 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 �L---GG 1A-clom 1.270 w 35.56 55.25 0 0 0 0 4A5.2om 0.770 w 21.56 45.63 0 0 0 0 p Ix2 osw s:.. 6.091,- 2:55.:. .1.28 0 0 0:: p C 16A30md 0.032 - 0.90 2.32 16g 169 151 392 F 2 A fpl 0.989 : 27.69' 0.00 169 13 360 .0 6 c)AED excursion -103 Envelope loss/gain 1430 1066 12 a) Infiltration 193 55 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 1 230 Appliances/other 0 Subtotal(lines 6 to 13) 1623 1351 Less erdemal_load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 1623 1351 15 Duct loads 31% 49% 497 668 Total room load 2120 2019 Air required(cfm) 95 84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 4j4- wrigjhtsc ft- Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:29:34 ACCA Page 6 ...\Quick Calcs\Documents\WYNNE P -ROYALE-REVISED.ru Calc=MJB Front Door faces: N I Duct S stem Summary. Job. . - wrightsoft° y Date: Entire House By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:.772-466.6799 Fax 772-466-6796 Email:QUICKCALCS ,AOL.COM Project - • • For. THE ROYALE WYNNE DEV., FT. PIERCE, FL Heating Cooling External static pressure 0.50. in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/.return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.286 in/100ft 0.286 in/1 OOft Actual air flow 1160 cfm 1160 cfm Total effective length(TEL) 175 ft Supply • Design Htg 'Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln (ft) Trunk BATH h 540 24 13 0.351 4.0 ox0 VIFx 27.3 115.0 st1' BEDROOM h 3408 152 139 0.286 7.0 OxO VIFx 40.1 135.0 st2 BEDROOM 2 h 5376 240 215 0.343. 7.0 OxO VIFx 30.8 115.0 st1 BEDROOM 3 h 2120 95 84 0.371 6.0 Ox0 VIFx 19.9 115.0 st1' BEDROOM-A h 3408 152 139 0.297 7.0 Ox 0 VIFx 33.1 135.0 st2 ENTRY h 1272 57 41 0.485 4.0 Ox0 VIFx 8.1 95.0 GREAT/DINING-A h 3714 - 166 163 0:300 7.0 OxO VIFx 31'7 135.0 st2' GREAT/DINING-B h 3714 166 163 0.309 7.0 ox0 VIFx 27.1 135.0 st2 KITCHEN c 3446 18 144 .0.376 7.0 Ox0 VIFx 18.1 115..0 st1 LAUNDRY h 820 37 18 0.369 4.0 Ox0 VIFx 20.4 115.0 st1! M.BATH h 1131 50 32 0.366 4.0 Ox 0 VIFx 21.6 115.0 st1 wic c 203 3 8 0.309 4.0 Ox0 VIFx 26.6 135.0 st2 - - I SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 639 613 0.286 814 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1103 -1119 0.286 802 16.0 0 x 0 VinlFlx it j t wri htsoft° 2017-Apr-1017:29:35 At � 9 Right-Suite®Universal 2017 17.0.14 RSUD8101 Page 1 ..\Quick Calcs\DocumentslWYNNE-ROYALE-REVISED.rup Calc=MJ8 Front Door faces: N I .i I i DetailReturn Branch Table Grille . Htg Clg TEL Design . Veloc Diam H x W Stud/Joist. Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx i t. wri htsoft° 2017-Apr-1017:29:35 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2 ...\Quick Calcs\DocumentslWYNNE-ROYALE-REVISED.rup Calc=MJ8 Front Door faces: N