HomeMy WebLinkAboutInspection Docs Planning&Development Services P} ' Building&Code Regulation Division O 2300 Virginia Ave,Rm 201 RECENED Fort Pierce,FL 34982 Phone:772-462-2165 Fax:772-462-6443 SEP-2 Y'2018 Permitting Department BLOWER DOOR TEST FORM St. Lucie County House Infiltration Test Certification Prescriptive and Performance Method Date: Per it M 1 0 q —0 "-1 Contractor: yn,•� vz� o�P r� �-^ Job Address: 2� 1/f g f aL^c� ��' ice ,� 3 Construction: (O New Construction—Complete ( ) Existing—After Addition House Infiltration Test Results SLC Climate Zone 2 CFM(50) Test Date: 12 a [g Volume= l l S b g ACH(50)=CFM(50)x 60/Volume= _ Mechanical Ventilation required less than 3 ACH Passing results must be&ACH(50)or less Pass ( )Fail FBC,Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through S. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f),(g)or(i)or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC,Residential Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w.c.(50 Pa)in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole-house mechanical ventilation in accordance with Section M1507.3. Testing Company Company Name: Pro-Duct Services address: 1915 Rio Vista Dr., Ft Pierce 34949 I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Section R402.4.1.2 Climate Zone 2. Signature: Printed Name: Martin Klein License/Certification#: 5061633 BUILDING PERFORMANCE INSTITUTE, INC. 107 Hermes Road,Swte 210����{ `•�`"'"""�"" �� Malta, NY 12020 - (877)274-1274 www.bpi.org rt- . K Martin Klein BPI ) r BPI ID# W61 33 s" (SEE REVERSE SIDE FOR DESIGNATIONS AND EXPIRATION DATES) CERTIFIED PROFESSIONAL DESIGNATION EXPIRATION DATE Infiltration&Duct Leakage(IDL) 4/262021 BUILDING PERFORMANCE INSTITUTE, INC. I 41\� P16i�`>�ib, Ye�001�1't:E:1G4'�' .h: fbifPkkt, FL 77 ;4 - Fax 772=46Z,6443 R"uest-for 30-Da j Temig it t y Power-tied'eate Date: l7 Pemfit'Mmber. ��T Proms Address: ,�. �D�`AICQ, C. 'C1 - THE UNDERSIGNED HERBY REQUEST RELEASE OF ELEC173CAL POWER TO THE ABOVE DESCRIBED PROPERTY,FOR A.PERIOD NOT-TQ EXCEED'TtfIRTY.(30)-DAYS,FOR THE PLIRPOSE OFTEMNG SYSTEMS . ANb E'U!PMENT IN PiZERARATTO,N FQR A FIAL,INSP�QN. IN CONSIDERATION OF APPROVAL OF THE R:EQIiST WE-1 MMY Adq'4OWLEi3GE ANO AGE AS FOLLOli ; 1. Ibis bmporary power.release is reguesbad for the above stated purpm only,and tiere wM be rso ocnupancy of any type,other than that permitted.by cofistruciion during this time period. 2. As wiWess by our signatures,We hereby agree to abide by all terms and-conditions of this agreement, Inclodffig Building Division:Policy,which is incorporated herein by reference. 3. All conditions:and requirern6ro fisted in the attached document erode"Requirements for 30 Day Power for'T,esdhg"ft e'been fuifiiled'and'the premise is ready for compliance inspection. 4. All requests for an,extension beyond 30 days•most be:made in writing to the 13triiding:offidal stating the reason for the requesL Povuer ma}r be r�naoved from the site and jor a Stop Work.Order issued if the Final Inspection has not beer►approved vothin 30-days. A fee df�100.00 will be required to lift the Stop Work Order. WE NERM RELEASE-AND AGREE.TO HOLD HARMLESS,ST. LUCIE COUNTY,AND THEIR EMPLOYEES FROM ALL UAMLI,T M AND CLl M -Of ANY TYPE OF NATt1Ri;E W'F;tICH KAY ARISE NOW OR IN THE FUTURE OUT OE THIS.T RANS�IMPN,INCi:USING ANY DAMAGE Yfl,HIC MAY BE INC:U�ZED.QUE-M THE DISUONDvtcftON of kxm=PowEk IN THE EVENT OE VIOLATION+OF THIS AGREEMENT- TW_WR_'S1=TURE DA G �xENv ..... 3i�iTi21C�OR DATE �\k ELECTPJM CONTRACMP,SIGNATUPI DATE L LO—J £000/£000d 66£-1 999L8L8ZLL. —WObd Z L:Z L 8 L 9'70£-80 i Planning &Development Services . = Building&Code Regulation Division RFCEf�Fo 2300 Virginia Ave Fort_ • t - Pierce, FL 34982 772-462 2172 Faxx 7772-462-6443 perms CEP d - �n1® St 14 epePart CERTIFICATE OF TERMITE TREATMENT c�,, '�N, CONSTRUCTION SOIL TREATMENT PERMIT #: 1709-0267 JOB ADDRESS: 2 VILLA BLANCA FORT PIERCE,FL 34951-2811 BUILDER/CONTRACTOR: WYNNE DEVELOPMENT PEST CONTROL CONTRACTOR: EVICT--A-BUG TERMITE&PEST CONTROL INC. PEST CONTROL LICENSE #:JB175775 We,the undersigned, hereby certify that we have pretreated the above described construction for subterranean termites in accordance with the standards of the National Pest Control Association. Square feet if area treated: 220 LF Chemicals used: DOMINION 2L Percentage of solution: -Q5% Total gallons used: 120 Date of Treatment: 04-24-2018 Time of Treatment: 12.30 Footing Slab 1st Treatment 1t Treatment Re-Treat Re-Treat Driveway Pools 1st Treatment 11t Treatment Re-Treat Re-Treat Other xxoax Perimeter for Final Inspection 15`Treatment Re-Treat 9-18-2018 Signature of Exterminator Date Note: There must be a completed form for each required treatment or re-treatment and this form must be on the job site to be picked up by the inspector at time of each inspection or the scheduled Inspection will fail and a re-inspection fee charged. FBC104.2.6 Certificate of Protective Treatment for prevention of tennites A weather resistantjobsite posting board shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed, providing a copy for the person the permit is issued to and another copy for the building permit files The Treatnent Certificate shall provide the product used,identrty of the applicator, lime and date of the treatment,site location,area treated, chemical used,percent concentration and number of gallons used, to establish a verifiable record of protective treatment If the soil chemical barrier method for termite prevention rs used,final exterior treatment shall be completed error to final building approval. St Lucie County requires for the final inspection for CO,a Permanent Sticker to be placed on the electrical panel box cover, listing all the treatments and dates of applications. Revised 7/24/2014 i (� RECEIVED "l JUN 1 1 2018 Professional Insulators of South Florida permitting Department FTC Insulation Installation Certificate St.Lude County To: St Lucie County Date: May 24,2018 Re: Lot/Block- Address: 2 Villa Blanca Project: The undersi ned hereby certifies that insulation has been installed in the above described property as follows: 1. Exterior CBS walls have been insulated with: Spray-on Cellulose Thickness in inches: Fiberglass Blankets Manufacturer: Fi Foil Rock Wool Blankets Density: X Aluminum Foil R-Value: R 4.1 Rigid Board Polystyrene Other 2. Ceilings(level)have been insulated with: Spray-on Cellulose Thickness in inches: 11.1 X Fiberglass Blown Manufacturer: Climatepro Rock Wool Blankets Density: Aluminum Foil R-Value: R-30 Polyurethane Open Cell SPF Ceilings(Inaccessible)insulated with: Spray-on Cellulose Thickness in inches: 9.5" X Fiberglass Blankets Manufacturer: Johns Manville Ignition Barrier Density: Fiberglass Blown R-Value: R-30 Cellulose Loose Fill Open Cell SPF 3. Interior kneewalls have been insulated with: Fiberglass Blankets Thickness in inches: Fiberglass Loose Fill Manufacturer: Rock Wool Density: Fiberglass Blown R-Value: lCellulose Loose Fill Open Cell SPF 4. Garage partition walls of A/C living area have X Fiberglass Blankets been insulated with: Rock Wool Thickness in inches: 3.5" Polyurethane Manufacturer: Johns Manville Spray-on Cellulose Density: Open Cell SPF R-Value: R-11 5. The following have been insulated: s aQataer/ // WYNNE BUILDING CORP. t / .�,® -'�� •fir'-. General Contract/Builder SEAL :o �m •�-. 2003 CBC1254041 10 .�� Competency# Professional Insulators of South Florida,Inc. Insulation Contractor By. By: AP P R®VE , . 71 Planning &Development Services "7i��= � Building &Code Regulation Division 2300 Virginia Ave Fort Pierce, FL 34982 772-462-2172 Fax 772-462-6443 CERTIFICATE OF TERMITE TREATMENT CONSTRUCTION SOIL TREATMENT PERMIT #: j V - JOB ADDRESS: Ma BUILDER/CONTRACTOR: -4(2 _ �y •.S f PEST CONTROL CONTRACTOR: E T-A-BUG TERMITE&PEST CONTROL INC. PEST CONTROL LICENSE #: JB175775 We, the undersigned, hereby certify that we have pretreated the above described construction for subterranean termites in accordance with the standards of the National Pest Control Association. Square feet if area treated: Chemicals used: DOMINION2L Percentage of solution: .05% Total gallons used: Date of Treatment: 4k Time of Treatment: '® 67) Footing Slab - - — 1st Treatment 1st Treatment Re-Treat Re-Treat Driveway Pools 1t Treatment 1st Treatment Re-TA�7'� Re-Treat _Other Perim et r for Final Inspection 15'Treatment Re-Treat Sig t of Exterminator date Note: There must be a completed form for each required treatment or re-treatment and this form must be on the job site to be picked up by the inspector at time of each inspection or the scheduled inspection will fail and a re-inspection fee charged. FBC104.2.6 Certificate of Protective Treatment for prevention of termites A weather resistantjobsite posting board shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed, providing a copy for the person the permit is issued to and another copy for the building permit files The Treatment Certificate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area treated, chemical used,percent concentration and number of gallons used, to establish a verifiable record of protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall be completed prior to final building approval. St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel box cover, listing all the treatments and dates of applications. Revised 7/24/2014 VIlk Aff �y�p A` A KELLER, SCHLEICHER & MaCWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772)337-7755 P.O. BOX 78-1377 SEBASTIAN FL 32978-1377 SEBASTIAN (772)589-0712 PALM BEACH (561)845-7445 www.ksmengineering.net MELBOURNE(321)768-8488 FAX(561)845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE(772)229-9093 C.A.:5693 FAX(772)589-6469 SOIL COMPACTION REPORT ASTM D 1567 and ASTM D 2922 DATE TESTED December 5, 2017 KSM JOB# : 173657-1 d/SS/ct PERMIT# 17090267 CONTRACTOR Wynne Development JOB LOCATION 2 Villa Blanca Spanish Lakes Country Club Village Ft. Pierce, Florida ITEM TESTED Compacted Foundation Fill TEST LOCATION DEPTH * PEN DRY MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1. N.E. 0" - 12" 33 108.6 111.4 97.5 2. S.E. 41 106.3 95.4 3. Center 37 107.4 96.4 4. S.W. 35 109.2 98.0 5. N.W. 40 111.5 100.1 Soil Description: Brown Sand 112.0 I I I I with Clay W In Place Moisture: E I I I I I I 6.7 Percent I I - -- - G 111.0Optimum Moisture: H 11.0 Percent T Max. Dry-Density: P110.0 ..j _ _....__.-.- 111.4 P.C.F. C @ Test Locations The I I Density & Penetrometer F I Readings Indicate the 109.0 I I— Degree of Compaction Meets p I I I Minimum Required R for Unsty�eol eEqpndation. Y * P4Dh'.` eUdi tf4n to Natural Grade. 1os.o $ —"9 10 111 12 3 14 o � • Moi ures.(o�/ti4��eigh �01 • - r 8 Jula e _ 4%, �eiD '�esid OF •;' Otll) ti77LQ r,FW' � p$t• �Lh County Building Department F t n •-59t yt, el>s'jilakes.com • ONAIL Ronald G. Keller, P.E.:37293/SI Lic. No.: 860 / Julie E. Keller_. P.E.: 68366 11 12/06/2017 16:53 7725896ii KSM ENGINEERING PAGE 01/01 SP0%L AV KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN(772)337-7755 P O, BOX 78-1377, SESASTIAN, FL. 32978-1377 SEBASTIAN (772)589•-0712 PALM BEACH(581) 845-7445 www.ksmengineering-not MELBOURNE(321)768-6458 FAX(561)845-8876 E-Mail; KSMOKSMENGINEERINCY.NET ST.LUCIE(772)229-9093 C.A.:5693 FAX(772)589-6469 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 MATE TESTED December 5, 2017 KSM JOB#: 173657-1 d/SS/ct PERMIT# 17090267 CONTRACTOR Wynne Development JOB LOCATION 2 Villa Blanca Spanish Lakes Country Club Village Ft. Pierce, Florida ITEM TESTED Compacted Foundation Fill TEST LOCATION DEPTH x PEN DRY MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1- N.E. 0"- 12" 33 108.6 111.4 97.5 2. S.E. 41 106.3 95.4 3. Center 37 107.4 96.4 4. S.W. , 35 109.2 98.0 5. N.W. 40 111.5 100.1 Soil Description: Brown Send 112.0 with Clay W In Place Moisture, E I 1 I I ! 6.7 Percent I IAil H111.0 .— fOptimum Moisture: I11.0 Percent T jIMax. Dry Density: P 111.4 P.C.F- 110.0 .. IQ Test Locations TheIDensity &Penetrometer I l Readings Indicate the Degree of Compaction Meets Minimum Required R j I I I I I for UnstWiediEgpndation. Y 108 0 I Patf.�el,�di f'�cgn to Natural Grade, g g 0RECEIVED Mois ure-9'0 of Dry Weight ' DEC 06 2017 July e, esid "a I= :' Permitting Department ' to:p �� County Building Department St. Lucie County, FL y lakes-com .'r.* �IYAI. ,•6'21+""S�Ronald G-Keller, PE.;37293 1 SI Lia.No.:860 / JUIiP E. Keller. I?E.:68366 Planning &Development Services J ` Building &Code Regulation Division 2300 Virginia Ave • Fort Pierce, FL 34982 772-462-2172 Fax 772-462-6443 CERTIFICATE OF TERMITE TREATMENT CONSTRUCTION SOIL TREATMENT PERMIT #: '� d - JOB ADDRE S: .Z ?/fII PL, 0.- FaAeYce �L,3 BUILDER/CONTRACTOR: e. PEST CONTROL CONTRACTOR: E T-A-BUG TERMITE&PEST CONTROL INC. PEST CONTROL LICENSE #: JB175775 We, the undersigned, hereby certify that we have pretreated the above described construction for subterranean termites in accordance with the standards of the National Pest Control Association. Square feet if area treated: glog Chemicals used: DOMINION 2L Percentage of solution: .05% Total gallons used: Jo Date of Treatment: 2 /� 1 T7 Time of Treatment: i3 0O Footing C/ Slabs 1st Treatment y 1s�Treatment Re-Treat Re-Treat Driveway Pools 1st Treatment 1st Treatment Re-Treat Re-Treat Other Perime 9nalInspection 1st Treatment Re-Treat L�sig�naof Exterminator Date 1 Note: There must be a completed form for each required treatment or re-treatment and this form must be on the job site to be picked up by the inspector at time of each inspection or the scheduled inspection will fail and a re inspection fee charged. FBC104.2.6 Certificate of Protective Treatment for prevention of termites A weather resistant jobsite posting board shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed, providing a copy for the person the permit is issued to and another copy for the building permit files The Treatment Certificate shall provide the product used, identity of the applicator, time and date of the treatment,site location, area treated, chemical used,percent concentration and number of gallons used, to establish a verifiable record of protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall be completed prior to final building approval, St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel box cover, listing all the treatments and dates of applications. Revised 7/24/2014 KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING,',, INC. MARTIN (772)337-7755 P.O. BOX 78-1377 SEBASTIAN FL 32978-1377 SEBASTIAN (772)589-0712 PALM BEACH (561)845-7445 www�ksmengineering.net MELBOURNE(321)768-M88 FAX(561)845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE(772)229-9093 C.A.:5693 FAX(772)589-6469 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 DATE TESTED December 5, 2017 KSM JOB# : 173657-1 d/SS/ct PERMIT# 17090267 CONTRACTOR Wynne Development JOB LOCATION 2 Villa Blanca Spanish Lakes Country Club Village Ft. Pierce, Florida ITEM TESTED Compacted Foundation Fill TEST LOCATION , DEPTH * PEN DRY MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1. N.E. 0" - 12" 33 108.6 111.4 97.5 2. S.E. If41 106.3 if95.4 3. Center 37 107.4 96.4 4. S.W. 35 109.2 98.0 5. N.W. 40 111.5 - 100.1 Soil Description: Brown Sand 112.0 - I I I I I with Clay W In Place Moisture: E I I I I I I 6.7 Percent I I I I I I G 111.0 Optimum Moisture: H I I I I I 11.0 Percent T --Max.-Dry Density: p 111.4 P.C.F. 110.0 j--.._..�.. �.._..�.._..�.. l_.._.. C I I I I I @ Test Locations The Density & Penetrometer IF l I I I Readings Indicate the 109.0 Degree of Compaction Meets D I I I I I I Minimum Required R I I I I I I for Unstaked Foundation. Y * Per2, ReValP�Rg9,Taken to Natural Grade. 108.0 �e _ e 8 9 10 11 12 13 14 R .• f M isR ECEINVEED d3resid DEC 11 2017 e •.a ._T St; ii County Building Department M �,� ootM W`lakes.com Permitting Department 01VA%,V ,, St. Lucie County, FL G. Keller, P.E.:37293/SI Lic. No.: 860 J Julie E. , .c..683r36