HomeMy WebLinkAboutEnergy Calculation Form & Manual J's F©RM R405--2014 ' C®-ny FLORIDA ENERGY EFFI CIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method I Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT Street WYNNE DEVELOPMENT Permit Office: ST.LUCIE COUNTY Oity,state,Zip: FT.PIERCE1,FL, Permit Number. Owner �j 1p A-4 Jurisdiction: Design Location; FL,ST LUCIE_CO_INTL County:: ST.LUCIE COUNTY(Florida Climate Zone 2) 11 New construction or existing New(From Plans) 9. Wall Types(1437.3 sgft.) Insulation Area i a.Concrete Block-Ext Insul,Exterior R=4.1 1250,00 Ill 2i Single family or multiple family Single-family b.Frame-Wood,Exterior = R 11.0 187.33ft2 3. Number of units,if multiple family 1 c.N/A R= It"4. Number of Bedrooms 2 d.Ni R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1446.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1446.00 ft2 6. Conditioned floor area above grade(ft2) 1446 b.N/A R= ft2 I Conditioned floor area below grade(ftz 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(139.2 Kill.) Description Area a.Sup:Attic,Ret:Attic,AK Attic 6 320 a, U-Factor. Dbl,U4.54 99.23 ftz SHGC: SHGC=0.25 b. U=Factor Dbl,U=0.55 40.00 ftz 12,Cooling systems kBtu/hr Efficiency SHGC: SHGC--i a.Central Unit 34.8 SEER:15.00 c. U-Factor. N/A ftz SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor.. NIA ftz a.Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.586 ft. Area Weighted Average SHGC: 0.250 14,Hot water systems 8. FtoorTypes (1448.0 W.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge insulation Rft0.0 1446.00 ftz b. Conservation features EF:0.970 b.NIA R= 42 None m N/A R= ft2 16.Credits Pstat Glass/FloorArea: 0.096 Total Proposed Modified Loads: 46.91 PASS Total Baseline Loads: 48.19 I hereby certify that the plans and specifications covered by Review of the plans and 04'iE S7'g2� this calculation are in compliance with the Florida Energy spe�cabons covered by this .y , C� Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY:4 Before construie lon is completed - DATE: this building will be inspected for lit' compliance with Section 553.908 I hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AG BUILDING OFFICIAL: --- DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1,2, 6/16/201711 A9 AM EnergyGaugec)USA-FiaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 i I 1 M R. 5-2014 PROJECT Title: THE GRAND CARLTON Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot# Owner: Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 135 Street: WYNNE DEVELOPME Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: ST.LUCIE COUNTY Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: I CLIMATE j IECC Design Temp Int Design Temp Heating Design Daily Temp v j Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,ST_LUCIE_CO_INTL FL VERO_13EACH_MUNI 2 39 90 70 75 299 58 Medium i ` BLOCKS Number Name Area Volume 1 I Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 234 1872 No 2 1 1 Yes Yes Yes 2 WIC 54 432 No 0 1 No Yes Yes 3 MASTER BATH 63 504 No 0 1 Yes Yes Yes 4 M.BATH 56 448 No 0 1 Yes Yes Yes 5 KITCHEN 172 1376 Yes 0 1 No Yes Yes 6 BATH 45 360 No 0 1 Yes Yes Yes 7 BEDROOM 2 204 1632 No 1 1 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 526 4208 No 0 1 Yes Yes Yes 10 FOYER 50 400 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio BEDROOM 40 ft 0 234 ftZ 0 1 0 2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 54 ftz ___- 0 1 0 3 Slab-On-Grade Edge Insulatio MASTER BATH 9 ft 0 63 ftz ____ 0 1 0 4SIab-On-Grade Edge Insulatio M.BATH. 8 ft 0 56 fta 0 1 0 5 Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 172 ftz ____ 0 1 0 6 Slab-On-Grade Edge Insulatio BATH 5 ft 0 45 ftZ -___ 0 1 0 7 Slab-On-Grade Edge Insulatio BEDROOM 2 34.2 ft 0 204 ftZ ____ 0 1 0 6/16! 017 11:49 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R4.QS-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab-On-Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ---- 0 1 0 9 Slab-On-Grade Edge Insulatio GREAT/DINING 47 ft 0 526 ft2 -_-_ 0 1 0 10SIab-On-Grade Edge Insulatio FOYER 7 ft 0 50 ft2 0 1 0 i ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch VI # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N I CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) BEDROOM 30 Blown 234 ft2 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 54 ft2 0.1 Wood 3 Under Attic(Vented) MASTER BATH 30 Blown 63 ft2 0.1 Wood 4 Under Attic(Vented) M.BATH 30 Blown 56 ft2 0.1 Wood 5 Under Attic(Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood 6 Under Attic(Vented) BATH 30 Blown 45 ft2 0.1 Wood 7 Under Attic(Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 8 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic(Vented) GREAT/DINING 30 Blown 526 ft2 0.1 Wood 10 Under Attic(Vented) FOYER 30 Blown 50 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 N=>SE Exterior Concrete Block-Ext Insf3EDROOM 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 2 S=>NW Exterior Concrete Block-Ext InsifflEDROOM 4.1 18 0 8 0 144.0 ft2 0 0 0.5 0 3 W=>NE Exterior Concrete Block-Ext InsdBEDROOM 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 4 S=>NW Exterior Concrete Block-Ext InsMASTER BA 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 5 S=>NW Exterior Concrete Block-Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 6 N=>SE Exterior Concrete Block-Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 7 N=>SE Exterior Concrete Block-Ext In'!REDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.5 0 8 E=>SW Exterior Concrete Block-Ext InQEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.5 0 9 SE=>W Exterior Concrete Block-Ext In�ffDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.5 0 10 S=>NW Exterior Concrete Block-Ext InQEDROOM 2 4.1 4 0 8 0 32.0 ft2 0 0 0.5 0 i 11 S=>NW Exterior Concrete Block-Ext InsdLAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0 12 N=>SE Exterior Concrete Block-Ext InsGREAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.5 0 i 6/1/2017 8:43 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R406-2014 WALLS Adjacent Cavity Width Height Sheathing Framing. Solar Below SpaceJa u. Et n Et In Area _ o F 1 13 W=>NE Exterior Concrete Block-Ext Ins`iiREAT/DINI 4.1 21 0 8 0 168.0 ft2 0 0 0.5 0 14 N=>SE Exterior Concrete Block-Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 15 E=>SW Exterior Concrete Block-Ext Insul FOYER 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0 I 16 N=>SE Exterior Frame-Wood GREAT/DIN[ 11 23 5 8 187.3 ft2 0.23 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E=>SW Insulated FOYER None .28 3 6 8 20 ft2 I WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 W=>NE 3 Metal Low-E Double Yes 0.54 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 S=>NW 5 Metal Low-E Double Yes 0.54 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 E=>SW 8 Metal Low-E Double Yes 0.54 0.25 23.2 ft2 1 ft 0 in 1 ft 4 in None None 4 N=>SE 12 Metal Low-E Double Yes 0.54 0.25 36.8 ft2 1 ft 0 in 1 ft 4 in None None 5 W=>NE 13 Metal Low-E Double Yes 0.55 0.25 40.0 ft2 10 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 315ft2 315ft2 24ft 8ft 11 I INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .2455 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts I 1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 I COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 6/ /2017 8:43 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 I FORM R405-2014 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 I DUCTS —Supply— --Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 320 ft2 Attic 80 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin ]Jan Feb Mar A r Ma X Jun Jul Au Se [ ]Oct Nov [ ]Dec Heating X]Jan f X�Feb Mar f Apr IM ay Jun Jul 4 Aug jXj SeP [ ]Oct Nov [X]Dec ]]Jan [ ]Feb X Mar [X]A r Ma Jun Jul [ Au Se [X]Oct X Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 . PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68. 68 68 .68 68 68 66 66 6/1/2017 8:43 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 1=oRM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT Street: WYNNE DEVELOPMENT Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number: Owner: Jurisdiction: Design Location: FL,ST_LUCIE_CO_INTL i COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Comers and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. i Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. hafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation. Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be I airtight, IC rated,and sealed to the drywall. i Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. i Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. ireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 6/11 1201711:54 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM ►R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. WYNNE DEVELOPMENT, FT. PIERCE, FL, 1. Nlew construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1250.00 ft2 1 b. Frame-Wood, Exterior R=11.0 187.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 2 d.N/A R= ft2 5. Is this a worst case? 10.Ceiling Types Insulation Area Yes a. Under Attic(Vented) R=30.0 1446.00 ft2 6. Conditioned floor area(ft2) 1446 b. N/A R= ft2 c R_ 2 7. Windows- Description Area 11 Ducts R ft2 a] U-Factor: Dbl,U=0.54 99.23 ft2 a.Sup:Attic, Ret:Attic,AH:Attic 6 320 SHGC: SHGC=0.25 b U-Factor: Dbl, U=0.55 40.00 ft2 SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.586 ft. a.Electric Heat Pump 34.8 HSPF:8.50 Airea Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14. Hot water systems a.Slab-On-Grade Edge Insulation R=0.0 1446.00 ft2 a. Electric Cap:40 gallons bJ N/A R= ft2 EF:0.97 ci N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building SSE 5 Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: �j '" ~ A° Address of New Home: �j `p City/FL Zip:� .p�CC.�� ✓�,c n v5�w �•�� ��t45� oD�� Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list.of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. i * Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. i 6/1/2017 8:43 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 Job::. • - - wrightsoft Project Summary Date: Enure House By: i QUICK CALCS,INC. �317 ST.'LUCIE LN.,FT.PIERCE,FL34946 Phone:772-466-6799 Fax 772.46"796 Emall:QUICKCALCS@AOL.COM i Project I • • I i For. THE GRAND CARLTON _ WYN;E DE EL�NT, FT. PIERCE, FL Notes: Design Information Weather. Fort Piece, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db. 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17848 Biuh Structure 17520 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent(0 cfm): 0 ,Btuh Central vent(0 cfm) 0 Btuh Humnone . idification 0 Btuh Blower e) 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Use manufacturer's data n Ratelswing multiplier 0.95 Infiltration Equipment sensible load 24753 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3203 Btuh Ducts 2318 Btuh Central vent(0 cfm) 0 Btuh Heatingg Cool" (none). Area(ft2) 1446 1446 Equipment latent load 5521 Btuh Volume(ft3) 12511 12511 Air changes/hour 0.45 0.23 Equipment total load 30274 Btuh Equiv.AVF(cfm) 94 48 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling-Equipment Summary Make " Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIERAIR CONDITIONING Model 25H.BC536A*030 Cond 25HBC536A*030 AHRI ref 7914585 Coil FX4DN(B;F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 24360. Btuh Heating output 34600 ,Btuh @ 47*F Latent cooling 10440 Btuh Temperature rise 27, OF Total cooling 34800 Btuh Actual*air flow.. 1160 cfm. Actual air flow 1160 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.045 cfm/Btuh . Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point=32 OF Backup: Input=7 kW, Output'=23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - - wrightsoft` 2017-Apr-11 09:29:38 Right-Suite®Universal 201717.0.14 RSU08101 Page 1 ACCK ..uick Cales\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door races: N !- wrightsoft' Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 1317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name Entire House BEDROOM 2 Exposed wall 156.2 ft 49.0 ft 3. Room height 8.7 ft d 8.0 ft heat/cool 1 4 Roam dimensions 1.0 x 297.0 ft 5 Room area 1445.5 ft2 297.0 ftz Ty Construction U-value Or HTM Area (ft5 Load Area (ft� Load number (Btuh/ft2L`F) (Btu 1) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) . Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs _0143 .ri..` :4:00 255 -503 465 1862 1184 72 72 288 183 4A5-2om .0.770 .n 21;56 19.31 :38 ' . 0 815 - 730 0: 0. :0. 0 13A4ocs 0.143 a 4.00 2.55 128 83 333 212 0 0 0 0 1Ac1om 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0 11 -D--DDD 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 'W = '13AAocs 0.143 se 4.00 2.65 34 34 136 86 0 0 0- 0 13A400s 0.143 s 4.00 2.55 360 353 1414 899 216 216 865 550 1Ac1om 1.270 s 35.56 34.77 7 7 247 241 0 0 0 0 13A-46cs 0 143 W 4 00 2.55 310 237 949 603 104. 72 288 183 1Ac1om.�;. 1270 ::w 3556 55:21 32 '- 2 1140: 1770 - 32'. 2 1140 1770. `4A5.2om:: 0.770 W 21.56 19:31 41 41 - 880. 788 0 0 0 0 P 12C-0sw 0.091 - 2.55 1.28 192 192 489 246_ 0 0 0 0 C 6A=30m_d' 10.032 -: . 0 90' . 2:32 1446 . 7446<. 1295;: . 3354';... 297' 297' 266' 689 22A•tpl 0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 c)AED excursion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 3 .690 Appliances/other 2000 0 Subtotal(lines 6 to 13) 17848 17520 5053 4925 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 6053 4925 15 Duct loads 32% 49% 5654 8536 32% 49% 1601 2400 Total room load 23503 26056 6653 7325 Air required(cfm) 1160 1160 328 326 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - ,wrightsoft• Right-Suite®Universal 2011 17.0.14 RSU08101 2017-Apr-11 06:29:38 A ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N Page 1 i wri 'htsoft- Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM. 1 Room name WIC KrrCHEN 2 Exposed wall O ft O ft 3 Room height 8.0 ft heat/cool 8.0 ft heaticool 4 Room dimensions 6.0 x 9.0 ft 1.0 x 172.0 ft 5 Room area 54.0 ftz 172.0 ftz Ty Construction Ll-value Or HTM Area number (Stuh/f?°F) (Btuh/ftz) or perimeter (ft) (Btuh) orsperimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross WP/S Heat Cool i 6 yJ 13A•4ocs-. 0143 n- 4;OQ .'2 65 0 D 0.. 0 . . .0. 0 - 0 0 G 4A5 tom. 0.770 'n' 21:56 1931 0 0 0 0. 0 :0,:.:, 0.. 0 VV13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 1A-clom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 1111DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W - 13A,4ocs 0.143 se. 4.00 2.65 0 0 0. 0 0 0 0 0 y/ 13A4ocs 0.143 s 4.00 Z55 0 0 0 0 0 0 0 0 Y-G 1A-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13Ar4acs 0143 w 4.00 2.55 0 0 0 0 0 0. 0 , 0 j 1A-,c1om 4270 w 3556• 55:21 0 0 0. 0 0 0 ' . 0 0 4A5 tom::: 0.776 w 21 56 19.31 0:- 0 0 . -0 0 .. 6:. 0 . 0 P 12C-Osw 0.091 - 2.55 1.28 0 0 0 0 64 64 163 82 C __`°__16A-30md:.= 0.032 Ot90 ' 2,32 54 54 "48 125 172.: 172 . .'-154 , 399 F 22A tpl 0.989 27.69 0.00 54 0 0 0 172 0 0 0 6 c)AED excursion -9 -170 Envelope loss/gain 48 117 317 311 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2000 Subtotal(lines 6 to 13) 48 117 317 2311 Less external load 0 0 0 0 Less transfer 0 0 0 0 i Redistribution 0 0 0 0 14 Subtotal 48 117 317 2311 15 Duct loads 32% 49% 15 57 32% 49% 1001 1126 Total room load 64 174 418 3437 Air required(cfm) 3 8 21 153 i Calculations approved byACCA to meet all requirements of Manual J.8th Ed. - - wcigfitsoft Right-Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 2 ...uick Calcs%DocumentslTHE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N I � ,1 - --wrightsoft- Right-M Worksheet Job: Entire House Date: QUICK CALLS, INC. By: 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6749 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name BATH BEDROOM 2 2 Exposed wall 5.0 ft 34.2 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 9.0 x 5.0 ft 1.0 x 203.5 ft 5 Room area 45.0 ft2 203.5 ft2 Ty Construction U-value. Or HTM Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeters(ft) (Btuh or (ftt Load perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Coal 8 W 13A flocs;; 0143 q:.; 400 255 40 40 160 102 '128 128 513 326 r G yAr2om> 0.770 n .. 2156.: . 19.31: 0 " . "0 .. p 0 0 "-0 :0 _ ;A 13AAocs 0.143 a 4.00 2.55 0 0 0, 0 80 56 225 143 T-G 1A-clom 1.270 a 35.56 87.29 0 0 0 0 24 2 848 2082 11 �D 11130 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W 13A-4ocs 0:143. se 4:00 Z55 0 .0 0 0 34 34 136 86 VN 13AAocs 0.143 s 4.00 2.55 0 0 0 0 32 32 128 81 L-C 1Aclom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13AAOCS 0143 w 4.00 255 0 0 0 0 0 '0 0 0 9Aclom 1270 w 35:56 55.21 0 0 0 0 0 0 0 0 4A5.2om' 0 770 ..w" . 21.56 19:31 0 0 0 0" 0 0: :0 0 P 12C-0sw 0.091 2.55 1.28 0 0 0 0 0 0 0 0 C , =16A30md 0032 0.90 232 :. `45 45 40: 104' ,204 204 182 472 F 22A-tpl 0.989 27.69 0.00 45 5 138 0 204 34 946 0 6 c)AED excursion _16 -85 Envelope loss/gain 339 190 2978 3106 12 a) Infiltration . 87 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal pines 6 to 13) 425 214 3571 M98 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 .Subtotal 425 214 3571 3498 15 Duct loads 32% 49% 135 104 32% 49% 1131 1704 Total room load 560 318 4702 5203 Air required(cfm) 28 14 232 232 Calculations approved byACCA to meet all requirements of Manual J.8th Ed. _Q= -�- wrightsoft- 2017-Apr-11 09:29:38 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 3 ...uick CalcslDocumentslTHE GRAND CARLTON-1446.rup Cale=MJ8 Front Door faces: N wrightsoft' Right-J®Worksheet Job: Entire House By: v: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@,AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 Bxposed wall 6.0 ft 47.0 ft 3 Room height 8.0 ft heat/cool 9.8 ft heat/cool 4 Room dimensions 7.0 x 6.0 ft 1.0 x. 526.0 ft 5 Room area 42.0 ft2 526.0 ft2 Ty .Construction Ll-value Or HTM Area (ft2) Load Area (ft-) Load number (BtuhlftX-°F) (Btu ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A46cs, :0143 n': 4 00. 2M -_0 0 0 0 255 217 869 552 r G: 4A5 tom. 0.770 n`- 21:56 19:31 0 0 D 0 38' 0 815. 730 W 13A4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 I{_Gp 1Ac1om 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W 13A4ocs 0.143 'se .4.00 255 0 0 0 0 0 0 0 0 V+/ 13A-4ocs 0.143 s 4.00 2.55 48 48 192 122 0 0 0 0 T_C 1Ac1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A46cs 0143 w 4.00 2.55 0 0 0 0 206 165 661 420 1Ac1om 1-270 .w. 3556 55.21_ .0 0 0. .0 0 0 0 -- 0 9A5 2om'_`- 0 770 ,w. 21.56: 19.81 0. 0 '. 0 . 0 41 41 880 788 P 12C-0sw 0.091. - 2.55 1.28 56 56 143 72 0 . 0 0 0 C <16A30md'. O .- ;0:90 2;32 42 42 38 97 526 526. 471 1220 F 22A tpl 0.989 - 27.69 0.00 42 6„ 166 0 526_ 47 1302 0 6 c)AED excursion -22 668 Envelope loss/gain 539 270 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ MO 0 0 2 460 Appliances/other 0 0 Subtotal(lines 6 to 13) 643 298 5994 5112 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 643 298 5994 5112 15 Duct loads 32% 49% 204 145 32% 49% 1899 2490 :ITTotal room load 8461 443 7892 7602 Air required(cfm) 42 20 390 338 j Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - - wrightsoft' 2017-Apr-11 09:29:38 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 4 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N - -wrightsoft Right-J®Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772466-6799 Fax 772-166-6796 Email:QUICKCALCS ,AOL.COM 1 Room name FOYER M.BATH 2 Bgposed wall 7.0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 50.0 ft 7.0 x 8.0 ft 5 Room area 50.0 ftz 56.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ftz-°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 Vd, 13A-0ocs. 0 143 A. . 4.00 255 8 8 32 :. 20 .4A5.2.om.: Or770 :.o;. .: 21:56 ;<19.3T': 0 0 0 0 0 Q 13A-4ocs 0.143 a 4.00 2.55 48 27 108 69 0 0 0 0 1A-clom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W 13A rocs 0:143 se 4.00 255 0 0 0 0 0 0 0 0 Vt! 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 64 57 228 145 L--G 1A-clom 1270 s 35.56 34.77 0 0 0 0 7 7 247 241 13A-4ocs .0143 w 4.00 2.55 0 0 0 0 0 0 .0 0 1A-clom- T.270 `w. 35.56 55.21 0 0 0.: 0. 0 20 0 •0 4A5 tom`_ 0 770:.w. 2156 19;31 0 0 0 0 0 0. 0... 0. P. 12C-0sw 0.091, - 2.55 1.28 72 72 183 92 0 0 0 0 G :,16A=30md:... A032 0:90- 2.32 :50 50 45 -116. 56' 56; -50 ,,130 F. 22A tpl 0.09 - 27.69 0.06 50 7 194 0 56 8 222 0 i i 6 c)AED excursion -39 -38 Envelope loss/gain 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(Iines 6 to 13) 913 529 885 . 516 Less external load 0 0 0 0 Less transfer 0. 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 885 516 15 Duct loads 32% 49% 289 258 32% 49% 280 251 Total room load 1202 787 1166 768 Air required(cfm) 59 35 58 34 I Calculations approved byACCA to meet all requirements of Manual 8th Ed. anirightsoft' Right-Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 5 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N 9 +- wrights®ft� Duct System Summary pat: Entire House By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone;.772-466-6799;Fax 772-466-6796 Email:QUICKCALCS@,AOL.COM Project Information For: THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL i I Heating. Cooling Extemal static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.285 in/100ft 0.285 in/100ft Actual air flow 1160 cfm 1160 cfm (Total effective length(TEL) 176 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv i Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 Ox0 VIFx 22.4 115.0 st1 BEDROOM h 4702 232 232 0.360 7.0 Ox0 VIFx 23.9 115.0 st1 BEDROOM-A h 3327 164 163 0.300 6.0 ox0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Ox 0 VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 ox0 VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 ox0 VIFx 31.8 135.0 st2 GREAT/DININGA h 3946 195 169 0.300 7.0 ox0 VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 ox0 VIFx 17.0 115.0 St1 LAUNDRY h 846 42 20 0.361 4.0 Ox 0 VIFx 23.3 115.0 st1 M,BATH-A h 768 58 34 0 0 Ox 0 VIFx 0 0 wlc c 174 3 8 0.309 4.0 Ox0 VIFx 27.0 135.0 st2 I i i Supply Trunk Detail • - Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFlx t wri htsoft° 2017-Apr-1109:29:3B 9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1 ACCK ..:uick Calcs\Dccuments\THE GRAND CARLTONA446.rup Calc=MJ8 Front Door faces: N • BranchReturn : Grille Htg Clg . TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm). (ft) FR (fpm). (in) (in) Opening(in) Math. Trunk , rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx i I i I 1 WPI htSOft` 2017-Apr-1109:29:38 9 RightSuite®Universal 2017 17.0.14 RSU08101 Page 2 )CM ...uick CalcslDocuments\THE GRAND CARJON-1446.rup Cale=MJ8 Front Door faces: N