HomeMy WebLinkAboutEnergy Calculation Form & Manual J's F©RM R405--2014 ' C®-ny
FLORIDA ENERGY EFFI
CIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
I
Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT
Street WYNNE DEVELOPMENT Permit Office: ST.LUCIE COUNTY
Oity,state,Zip: FT.PIERCE1,FL, Permit Number.
Owner �j 1p A-4 Jurisdiction:
Design Location; FL,ST LUCIE_CO_INTL County:: ST.LUCIE COUNTY(Florida Climate Zone 2)
11 New construction or existing New(From Plans) 9. Wall Types(1437.3 sgft.) Insulation Area
i a.Concrete Block-Ext Insul,Exterior R=4.1 1250,00 Ill
2i Single family or multiple family Single-family b.Frame-Wood,Exterior =
R 11.0 187.33ft2
3. Number of units,if multiple family 1 c.N/A R= It"4. Number of Bedrooms 2 d.Ni R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1446.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1446.00 ft2
6. Conditioned floor area above grade(ft2) 1446 b.N/A R= ft2
I Conditioned floor area below grade(ftz 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(139.2 Kill.) Description Area a.Sup:Attic,Ret:Attic,AK Attic 6 320
a, U-Factor. Dbl,U4.54 99.23 ftz
SHGC: SHGC=0.25
b. U=Factor Dbl,U=0.55 40.00 ftz 12,Cooling systems kBtu/hr Efficiency
SHGC: SHGC--i a.Central Unit 34.8 SEER:15.00
c. U-Factor. N/A ftz
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor.. NIA ftz a.Electric Heat Pump 34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.586 ft.
Area Weighted Average SHGC: 0.250 14,Hot water systems
8. FtoorTypes (1448.0 W.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge insulation Rft0.0 1446.00 ftz b. Conservation features EF:0.970
b.NIA R= 42 None
m N/A R= ft2 16.Credits Pstat
Glass/FloorArea: 0.096 Total Proposed Modified Loads: 46.91 PASS
Total Baseline Loads: 48.19
I hereby certify that the plans and specifications covered by Review of the plans and 04'iE S7'g2�
this calculation are in compliance with the Florida Energy spe�cabons covered by this .y , C�
Code. calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:4 Before construie lon is completed -
DATE: this building will be inspected for lit'
compliance with Section 553.908
I hereby certify that this building,as designed,is in compliance Florida Statutes.
with the Florida Energy Code.
OWNER/AG BUILDING OFFICIAL: ---
DATE: DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1,2,
6/16/201711 A9 AM EnergyGaugec)USA-FiaRes2014 Section R405.4.1 Compliant Software Page 1 of 6
i
I
1
M R. 5-2014
PROJECT
Title: THE GRAND CARLTON Bedrooms: 2 Address Type: Street Address
Building Type: User Conditioned Area: 1446 Lot#
Owner: Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 135 Street: WYNNE DEVELOPME
Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: ST.LUCIE COUNTY
Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
I
CLIMATE
j IECC Design Temp Int Design Temp Heating Design Daily Temp
v j Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,ST_LUCIE_CO_INTL FL VERO_13EACH_MUNI 2 39 90 70 75 299 58 Medium
i
` BLOCKS
Number Name Area Volume
1 I Entire House 1446 11568
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 BEDROOM 234 1872 No 2 1 1 Yes Yes Yes
2 WIC 54 432 No 0 1 No Yes Yes
3 MASTER BATH 63 504 No 0 1 Yes Yes Yes
4 M.BATH 56 448 No 0 1 Yes Yes Yes
5 KITCHEN 172 1376 Yes 0 1 No Yes Yes
6 BATH 45 360 No 0 1 Yes Yes Yes
7 BEDROOM 2 204 1632 No 1 1 1 Yes Yes Yes
8 LAUNDRY 42 336 No 0 1 Yes Yes Yes
9 GREAT/DINING 526 4208 No 0 1 Yes Yes Yes
10 FOYER 50 400 No 0 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio BEDROOM 40 ft 0 234 ftZ 0 1 0
2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 54 ftz ___- 0 1 0
3 Slab-On-Grade Edge Insulatio MASTER BATH 9 ft 0 63 ftz ____ 0 1 0
4SIab-On-Grade Edge Insulatio M.BATH. 8 ft 0 56 fta 0 1 0
5 Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 172 ftz ____ 0 1 0
6 Slab-On-Grade Edge Insulatio BATH 5 ft 0 45 ftZ -___ 0 1 0
7 Slab-On-Grade Edge Insulatio BEDROOM 2 34.2 ft 0 204 ftZ ____ 0 1 0
6/16! 017 11:49 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R4.QS-2014
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
8 Slab-On-Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ---- 0 1 0
9 Slab-On-Grade Edge Insulatio GREAT/DINING 47 ft 0 526 ft2 -_-_ 0 1 0
10SIab-On-Grade Edge Insulatio FOYER 7 ft 0 50 ft2 0 1 0
i
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
VI # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 0 18.4
ATTIC
# Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 1446 ft2 N N
I
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) BEDROOM 30 Blown 234 ft2 0.1 Wood
2 Under Attic(Vented) WIC 30 Blown 54 ft2 0.1 Wood
3 Under Attic(Vented) MASTER BATH 30 Blown 63 ft2 0.1 Wood
4 Under Attic(Vented) M.BATH 30 Blown 56 ft2 0.1 Wood
5 Under Attic(Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood
6 Under Attic(Vented) BATH 30 Blown 45 ft2 0.1 Wood
7 Under Attic(Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood
8 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood
9 Under Attic(Vented) GREAT/DINING 30 Blown 526 ft2 0.1 Wood
10 Under Attic(Vented) FOYER 30 Blown 50 ft2 0.1 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
0
1 N=>SE Exterior Concrete Block-Ext Insf3EDROOM 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0
2 S=>NW Exterior Concrete Block-Ext InsifflEDROOM 4.1 18 0 8 0 144.0 ft2 0 0 0.5 0
3 W=>NE Exterior Concrete Block-Ext InsdBEDROOM 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0
4 S=>NW Exterior Concrete Block-Ext InsMASTER BA 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0
5 S=>NW Exterior Concrete Block-Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0
6 N=>SE Exterior Concrete Block-Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0
7 N=>SE Exterior Concrete Block-Ext In'!REDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.5 0
8 E=>SW Exterior Concrete Block-Ext InQEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.5 0
9 SE=>W Exterior Concrete Block-Ext In�ffDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.5 0
10 S=>NW Exterior Concrete Block-Ext InQEDROOM 2 4.1 4 0 8 0 32.0 ft2 0 0 0.5 0
i
11 S=>NW Exterior Concrete Block-Ext InsdLAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0
12 N=>SE Exterior Concrete Block-Ext InsGREAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.5 0
i
6/1/2017 8:43 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R406-2014
WALLS
Adjacent Cavity Width Height Sheathing Framing. Solar Below
SpaceJa u. Et n Et In Area _ o
F 1 13 W=>NE Exterior Concrete Block-Ext Ins`iiREAT/DINI 4.1 21 0 8 0 168.0 ft2 0 0 0.5 0
14 N=>SE Exterior Concrete Block-Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0
15 E=>SW Exterior Concrete Block-Ext Insul FOYER 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0
I
16 N=>SE Exterior Frame-Wood GREAT/DIN[ 11 23 5 8 187.3 ft2 0.23 0.5 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 E=>SW Insulated FOYER None .28 3 6 8 20 ft2
I
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 W=>NE 3 Metal Low-E Double Yes 0.54 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5
2 S=>NW 5 Metal Low-E Double Yes 0.54 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in None None
3 E=>SW 8 Metal Low-E Double Yes 0.54 0.25 23.2 ft2 1 ft 0 in 1 ft 4 in None None
4 N=>SE 12 Metal Low-E Double Yes 0.54 0.25 36.8 ft2 1 ft 0 in 1 ft 4 in None None
5 W=>NE 13 Metal Low-E Double Yes 0.55 0.25 40.0 ft2 10 ft 0 in 1 ft 4 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 315ft2 315ft2 24ft 8ft 11
I
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .2455 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
I
1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1
I
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1
6/ /2017 8:43 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
I
FORM R405-2014
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
I
DUCTS
—Supply— --Return— Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 320 ft2 Attic 80 ft2 Default Leakage Attic (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Coolin ]Jan Feb Mar A r Ma X Jun Jul Au Se [ ]Oct Nov [ ]Dec
Heating X]Jan f X�Feb Mar f Apr IM
ay Jun Jul 4 Aug jXj SeP [ ]Oct Nov [X]Dec
]]Jan [ ]Feb X Mar [X]A r Ma Jun Jul [ Au Se [X]Oct X Nov [ ]Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 .
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68. 68 68 .68 68 68 66 66
6/1/2017 8:43 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
1=oRM R405-2014 TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT
Street: WYNNE DEVELOPMENT Permit Office: ST.LUCIE COUNTY
City,State,Zip: FT.PIERCE,FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL,ST_LUCIE_CO_INTL
i
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings,drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Comers and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
i
Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
hafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation. Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
I airtight, IC rated,and sealed to the drywall.
i
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
i
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
ireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
6/11 1201711:54 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FORM ►R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
WYNNE DEVELOPMENT, FT. PIERCE, FL,
1. Nlew construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1250.00 ft2
1 b. Frame-Wood, Exterior R=11.0 187.33 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 2 d.N/A R= ft2
5. Is this a worst case? 10.Ceiling Types Insulation Area
Yes a. Under Attic(Vented) R=30.0 1446.00 ft2
6. Conditioned floor area(ft2) 1446 b. N/A R= ft2
c R_ 2
7. Windows- Description Area 11 Ducts R ft2
a] U-Factor: Dbl,U=0.54 99.23 ft2 a.Sup:Attic, Ret:Attic,AH:Attic 6 320
SHGC: SHGC=0.25
b U-Factor: Dbl, U=0.55 40.00 ft2
SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 34.8 SEER:15.00
SHGC:
d. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
Area Weighted Average Overhang Depth: 3.586 ft. a.Electric Heat Pump 34.8 HSPF:8.50
Airea Weighted Average SHGC: 0.250
8. Floor Types Insulation Area 14. Hot water systems
a.Slab-On-Grade Edge Insulation R=0.0 1446.00 ft2 a. Electric Cap:40 gallons
bJ N/A R= ft2 EF:0.97
ci N/A R= ft2 b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building SSE 5
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date: �j '" ~ A°
Address of New Home: �j `p City/FL Zip:� .p�CC.�� ✓�,c n v5�w
�•�� ��t45� oD��
Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list.of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
i
* Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
i
6/1/2017 8:43 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
Job::.
• - - wrightsoft Project Summary Date:
Enure House By:
i QUICK CALCS,INC.
�317 ST.'LUCIE LN.,FT.PIERCE,FL34946 Phone:772-466-6799 Fax 772.46"796 Emall:QUICKCALCS@AOL.COM
i
Project I • •
I
i
For. THE GRAND CARLTON
_ WYN;E DE EL�NT, FT. PIERCE, FL
Notes:
Design Information
Weather. Fort Piece, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 42 OF Outside db 90 OF
Inside db 70 OF Inside db. 75 OF
Design TD 28 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 61 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 17848 Biuh Structure 17520 Btuh
Ducts 5654 Btuh Ducts 8536 Btuh
Central vent(0 cfm): 0 ,Btuh Central vent(0 cfm) 0 Btuh
Humnone .
idification 0 Btuh Blower e) 0 Btuh
Piping 0 Btuh
Equipment load 23503 Btuh Use manufacturer's data n
Ratelswing multiplier 0.95
Infiltration Equipment sensible load 24753 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 3203 Btuh
Ducts 2318 Btuh
Central vent(0 cfm) 0 Btuh
Heatingg Cool" (none).
Area(ft2) 1446 1446 Equipment latent load 5521 Btuh
Volume(ft3) 12511 12511
Air changes/hour 0.45 0.23 Equipment total load 30274 Btuh
Equiv.AVF(cfm) 94 48 Req. total capacity at 0.70 SHR 2.9 ton
Heating Equipment Summary Cooling-Equipment Summary
Make " Carrier Make Carrier
Trade CARRIER AIR CONDITIONING Trade CARRIERAIR CONDITIONING
Model 25H.BC536A*030 Cond 25HBC536A*030
AHRI ref 7914585 Coil FX4DN(B;F)037
AHRI ref 7914585
Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER
Heating input Sensible cooling 24360. Btuh
Heating output 34600 ,Btuh @ 47*F Latent cooling 10440 Btuh
Temperature rise 27, OF Total cooling 34800 Btuh
Actual*air flow.. 1160 cfm. Actual air flow 1160 cfm
Air flow factor 0.049 cfm/Btuh Air flow factor 0.045 cfm/Btuh .
Static pressure 0.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.83
Capacity balance point=32 OF
Backup:
Input=7 kW, Output'=23009 Btuh, 100 AFUE
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
- - wrightsoft` 2017-Apr-11 09:29:38
Right-Suite®Universal 201717.0.14 RSU08101 Page 1
ACCK ..uick Cales\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door races: N
!- wrightsoft' Right-M Worksheet Job:
Entire House Date:
By:
QUICK CALCS, INC.
1317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name Entire House BEDROOM
2 Exposed wall 156.2 ft 49.0 ft
3. Room height 8.7 ft d 8.0 ft heat/cool
1 4 Roam dimensions 1.0 x 297.0 ft
5 Room area 1445.5 ft2 297.0 ftz
Ty Construction U-value Or HTM Area (ft5 Load Area (ft� Load
number (Btuh/ft2L`F) (Btu 1) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) .
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-4ocs _0143 .ri..` :4:00 255 -503 465 1862 1184 72 72 288 183
4A5-2om .0.770 .n 21;56 19.31 :38 ' . 0 815 - 730 0: 0. :0. 0
13A4ocs 0.143 a 4.00 2.55 128 83 333 212 0 0 0 0
1Ac1om 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0
11 -D--DDD 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0
'W = '13AAocs 0.143 se 4.00 2.65 34 34 136 86 0 0 0- 0
13A400s 0.143 s 4.00 2.55 360 353 1414 899 216 216 865 550
1Ac1om 1.270 s 35.56 34.77 7 7 247 241 0 0 0 0
13A-46cs 0 143 W 4 00 2.55 310 237 949 603 104. 72 288 183
1Ac1om.�;. 1270 ::w 3556 55:21 32 '- 2 1140: 1770 - 32'. 2 1140 1770.
`4A5.2om:: 0.770 W 21.56 19:31 41 41 - 880. 788 0 0 0 0
P 12C-0sw 0.091 - 2.55 1.28 192 192 489 246_ 0 0 0 0
C 6A=30m_d' 10.032 -: . 0 90' . 2:32 1446 . 7446<. 1295;: . 3354';... 297' 297' 266' 689
22A•tpl 0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 0
6 c)AED excursion 918 627
Envelope loss/gain 14961 13349 4204 4003
12 a) Infiltration 2887 791 848 232
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 6 1380 3 .690
Appliances/other 2000 0
Subtotal(lines 6 to 13) 17848 17520 5053 4925
Less extemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 17848 17520 6053 4925
15 Duct loads 32% 49% 5654 8536 32% 49% 1601 2400
Total room load 23503 26056 6653 7325
Air required(cfm) 1160 1160 328 326
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
- ,wrightsoft• Right-Suite®Universal 2011 17.0.14 RSU08101 2017-Apr-11 06:29:38
A ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N Page 1
i
wri 'htsoft- Right-M Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By:
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM.
1 Room name WIC KrrCHEN
2 Exposed wall O ft O ft
3 Room height 8.0 ft heat/cool 8.0 ft heaticool
4 Room dimensions 6.0 x 9.0 ft 1.0 x 172.0 ft
5 Room area 54.0 ftz 172.0 ftz
Ty Construction Ll-value Or HTM Area
number (Stuh/f?°F) (Btuh/ftz) or perimeter (ft) (Btuh) orsperimeter (ft) (Btuh)
Heat Cool Gross NIP/S Heat Cool Gross WP/S Heat Cool
i
6 yJ 13A•4ocs-. 0143 n- 4;OQ .'2 65 0 D 0.. 0 . . .0. 0 - 0 0
G 4A5 tom. 0.770 'n' 21:56 1931 0 0 0 0. 0 :0,:.:, 0.. 0
VV13A-4ocs
0.143 a 4.00 2.55 0 0 0 0 0 0 0 0
1A-clom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0
1111DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0
W - 13A,4ocs 0.143 se. 4.00 2.65 0 0 0. 0 0 0 0 0
y/ 13A4ocs 0.143 s 4.00 Z55 0 0 0 0 0 0 0 0
Y-G 1A-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
13Ar4acs 0143 w 4.00 2.55 0 0 0 0 0 0. 0 , 0
j 1A-,c1om 4270 w 3556• 55:21 0 0 0. 0 0 0 ' . 0 0
4A5 tom::: 0.776 w 21 56 19.31 0:- 0 0 . -0 0 .. 6:. 0 . 0
P 12C-Osw 0.091 - 2.55 1.28 0 0 0 0 64 64 163 82
C __`°__16A-30md:.= 0.032 Ot90 ' 2,32 54 54 "48 125 172.: 172 . .'-154 , 399
F 22A tpl 0.989 27.69 0.00 54 0 0 0 172 0 0 0
6 c)AED excursion -9 -170
Envelope loss/gain 48 117 317 311
12 a) Infiltration 0 0 0 0
b) Room ventilation 0 0 0 0
13 internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 2000
Subtotal(lines 6 to 13) 48 117 317 2311
Less external load 0 0 0 0
Less transfer 0 0 0 0
i Redistribution 0 0 0 0
14 Subtotal 48 117 317 2311
15 Duct loads 32% 49% 15 57 32% 49% 1001 1126
Total room load 64 174 418 3437
Air required(cfm) 3 8 21 153
i
Calculations approved byACCA to meet all requirements of Manual J.8th Ed.
- - wcigfitsoft Right-Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 2
...uick Calcs%DocumentslTHE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N
I �
,1 - --wrightsoft- Right-M Worksheet Job:
Entire House Date:
QUICK CALLS, INC. By:
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6749 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name BATH BEDROOM 2
2 Exposed wall 5.0 ft 34.2 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 9.0 x 5.0 ft 1.0 x 203.5 ft
5 Room area 45.0 ft2 203.5 ft2
Ty Construction U-value. Or HTM Area (ft2) Load
number (Btuh/ft2-°F) (Btuh/ft2) or perimeters(ft) (Btuh or (ftt Load
perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Coal
8 W 13A flocs;; 0143 q:.; 400 255 40 40 160 102 '128 128 513 326
r G yAr2om> 0.770 n .. 2156.: . 19.31: 0 " . "0 .. p 0 0 "-0 :0 _ ;A
13AAocs 0.143 a 4.00 2.55 0 0 0, 0 80 56 225 143
T-G 1A-clom 1.270 a 35.56 87.29 0 0 0 0 24 2 848 2082
11 �D 11130 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0
W 13A-4ocs 0:143. se 4:00 Z55 0 .0 0 0 34 34 136 86
VN 13AAocs 0.143 s 4.00 2.55 0 0 0 0 32 32 128 81
L-C 1Aclom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
13AAOCS 0143 w 4.00 255 0 0 0 0 0 '0 0 0
9Aclom 1270 w 35:56 55.21 0 0 0 0 0 0 0 0
4A5.2om' 0 770 ..w" . 21.56 19:31 0 0 0 0" 0 0: :0 0
P 12C-0sw 0.091 2.55 1.28 0 0 0 0 0 0 0 0
C , =16A30md 0032 0.90 232 :. `45 45 40: 104' ,204 204 182 472
F 22A-tpl 0.989 27.69 0.00 45 5 138 0 204 34 946 0
6 c)AED excursion _16 -85
Envelope loss/gain 339 190 2978 3106
12 a) Infiltration . 87 24 593 162
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 1 230
Appliances/other 0 0
Subtotal pines 6 to 13) 425 214 3571 M98
Less extemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 .Subtotal 425 214 3571 3498
15 Duct loads 32% 49% 135 104 32% 49% 1131 1704
Total room load 560 318 4702 5203
Air required(cfm) 28 14 232 232
Calculations approved byACCA to meet all requirements of Manual J.8th Ed.
_Q= -�- wrightsoft- 2017-Apr-11 09:29:38
Right-Suite®Universal 2017 17.0.14 RSU08101 Page 3
...uick CalcslDocumentslTHE GRAND CARLTON-1446.rup Cale=MJ8 Front Door faces: N
wrightsoft' Right-J®Worksheet Job:
Entire House By:
v:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@,AOL.COM
1 Room name LAUNDRY GREAT/DINING
2 Bxposed wall 6.0 ft 47.0 ft
3 Room height 8.0 ft heat/cool 9.8 ft heat/cool
4 Room dimensions 7.0 x 6.0 ft 1.0 x. 526.0 ft
5 Room area 42.0 ft2 526.0 ft2
Ty .Construction Ll-value Or HTM Area (ft2) Load Area (ft-) Load
number (BtuhlftX-°F) (Btu ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A46cs, :0143 n': 4 00. 2M -_0 0 0 0 255 217 869 552
r G: 4A5 tom. 0.770 n`- 21:56 19:31 0 0 D 0 38' 0 815. 730
W 13A4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0
I{_Gp 1Ac1om 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0
11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0
W 13A4ocs 0.143 'se .4.00 255 0 0 0 0 0 0 0 0
V+/ 13A-4ocs 0.143 s 4.00 2.55 48 48 192 122 0 0 0 0
T_C 1Ac1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
13A46cs 0143 w 4.00 2.55 0 0 0 0 206 165 661 420
1Ac1om 1-270 .w. 3556 55.21_ .0 0 0. .0 0 0 0 -- 0
9A5 2om'_`- 0 770 ,w. 21.56: 19.81 0. 0 '. 0 . 0 41 41 880 788
P 12C-0sw 0.091. - 2.55 1.28 56 56 143 72 0 . 0 0 0
C <16A30md'. O .- ;0:90 2;32 42 42 38 97 526 526. 471 1220
F 22A tpl 0.989 - 27.69 0.00 42 6„ 166 0 526_ 47 1302 0
6 c)AED excursion -22 668
Envelope loss/gain 539 270 4997 4379
12 a) Infiltration 104 28 997 273
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ MO 0 0 2 460
Appliances/other 0 0
Subtotal(lines 6 to 13) 643 298 5994 5112
Less extemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 643 298 5994 5112
15 Duct loads 32% 49% 204 145 32% 49% 1899 2490
:ITTotal room load 8461 443 7892 7602
Air required(cfm) 42 20 390 338
j
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
- - wrightsoft' 2017-Apr-11 09:29:38
Right-Suite®Universal 2017 17.0.14 RSU08101 Page 4
...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N
- -wrightsoft Right-J®Worksheet
Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772466-6799 Fax 772-166-6796 Email:QUICKCALCS ,AOL.COM
1 Room name FOYER M.BATH
2 Bgposed wall 7.0 ft 8.0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 1.0 x 50.0 ft 7.0 x 8.0 ft
5 Room area 50.0 ftz 56.0 ftz
Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load
number (Btuh/ftz-°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool
6 Vd, 13A-0ocs. 0 143 A. . 4.00 255 8 8 32 :. 20
.4A5.2.om.: Or770 :.o;. .: 21:56 ;<19.3T': 0 0 0 0 0 Q
13A-4ocs 0.143 a 4.00 2.55 48 27 108 69 0 0 0 0
1A-clom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0
11 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0
W 13A rocs 0:143 se 4.00 255 0 0 0 0 0 0 0 0
Vt! 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 64 57 228 145
L--G 1A-clom 1270 s 35.56 34.77 0 0 0 0 7 7 247 241
13A-4ocs .0143 w 4.00 2.55 0 0 0 0 0 0 .0 0
1A-clom- T.270 `w. 35.56 55.21 0 0 0.: 0. 0 20 0 •0
4A5 tom`_ 0 770:.w. 2156 19;31 0 0 0 0 0 0. 0... 0.
P. 12C-0sw 0.091, - 2.55 1.28 72 72 183 92 0 0 0 0
G :,16A=30md:... A032 0:90- 2.32 :50 50 45 -116. 56' 56; -50 ,,130
F. 22A tpl 0.09 - 27.69 0.06 50 7 194 0 56 8 222 0
i
i
6 c)AED excursion -39 -38
Envelope loss/gain 792 496 747 478
12 a) Infiltration 121 33 138 38
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(Iines 6 to 13) 913 529 885 . 516
Less external load 0 0 0 0
Less transfer 0. 0 0 0
Redistribution 0 0 0 0
14 Subtotal 913 529 885 516
15 Duct loads 32% 49% 289 258 32% 49% 280 251
Total room load 1202 787 1166 768
Air required(cfm) 59 35 58 34
I
Calculations approved byACCA to meet all requirements of Manual 8th Ed.
anirightsoft' Right-Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 5
...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N 9
+- wrights®ft� Duct System Summary pat:
Entire House By:
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone;.772-466-6799;Fax 772-466-6796 Email:QUICKCALCS@,AOL.COM
Project Information
For: THE GRAND CARLTON
WYNNE DEVELOPMENT, FT. PIERCE, FL
i
I
Heating. Cooling
Extemal static pressure 0.50 in H2O 0.50 in H2O
Pressure losses 0 in H2O 0 in H2O
Available static pressure 0.50 in H2O 0.50 in H2O
Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O
Lowest friction rate 0.285 in/100ft 0.285 in/100ft
Actual air flow 1160 cfm 1160 cfm
(Total effective length(TEL) 176 ft
SupplyDetail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
i
Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln (ft) Trunk
BATH h 560 28 14 0.364 4.0 Ox0 VIFx 22.4 115.0 st1
BEDROOM h 4702 232 232 0.360 7.0 Ox0 VIFx 23.9 115.0 st1
BEDROOM-A h 3327 164 163 0.300 6.0 ox0 VIFx 31.8 135.0 st2
BEDROOM-B h 3327 164 163 0.285 6.0 Ox 0 VIFx 40.6 135.0 st2
FOYER h 1202 59 35 0.505 4.0 ox0 VIFx 4.0 95.0
GREAT/DINING h 3946 195 169 0.300 7.0 ox0 VIFx 31.8 135.0 st2
GREAT/DININGA h 3946 195 169 0.300 7.0 ox0 VIFx 31.8 135.0 st2
KITCHEN c 3437 21 153 0.379 6.0 ox0 VIFx 17.0 115.0 St1
LAUNDRY h 846 42 20 0.361 4.0 Ox 0 VIFx 23.3 115.0 st1
M,BATH-A h 768 58 34 0 0 Ox 0 VIFx 0 0
wlc c 174 3 8 0.309 4.0 Ox0 VIFx 27.0 135.0 st2
I
i
i
Supply Trunk Detail • -
Trunk Htg Cig Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VinlFlx st1
st1 Peak AVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFlx
t wri htsoft° 2017-Apr-1109:29:3B
9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1
ACCK ..:uick Calcs\Dccuments\THE GRAND CARLTONA446.rup Calc=MJ8 Front Door faces: N
• BranchReturn :
Grille Htg Clg . TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (cfm) (cfm). (ft) FR (fpm). (in) (in) Opening(in) Math. Trunk
,
rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx
i
I
i
I
1 WPI htSOft` 2017-Apr-1109:29:38
9 RightSuite®Universal 2017 17.0.14 RSU08101 Page 2
)CM ...uick CalcslDocuments\THE GRAND CARJON-1446.rup Cale=MJ8 Front Door faces: N