Loading...
HomeMy WebLinkAboutEnergy Calculation Form & Manual J's FORM R405-2014 �Ie' CCP µFLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT Street: WYNNE DEVELOPMENT Permit Office: ST. LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number: Owner: 3 � CA- . Jurisdiction: Design Location: FL,ST_LU CIE _CO_INTL County:: ST. LUCIE COUNTY(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1437.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1250.00 ftz b. Frame-Wood,Exterior R=11.0 187.33 ftz 3. Number of units,if multiple family 1 c.N/A z R= ft 4. INumber of Bedrooms 2 d.N/A R= ftz 5. Ili this a worst case? Yes 10.Ceiling Types (1446.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1446.00 ftz 6. IConditioned floor area above grade(ftz) 1446 b.N/A R= ftz IConditioned floor area below grade(ftz) 0 c.N/A R= ftz 11.Ducts R ftz 7. Windows(139.2 sqft.) Description Area a.Sup:Attic, Ret:Attic,AH:Attic 6 320 a. U-Factor: Dbl,U=0.54 99.23 ftz SHGC: SHGC=0.25 b. U-Factor: Dbl,U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency ''I SHGC: SHGC=0.25 a.Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ftz SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a.Electric Heat Pump 34.8 HSPF:8.50 11 SHGC: Area Weighted Average Overhang Depth: 3.586 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. �F'loorTypes (1446.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.970 a.Slab-On-Grade Edge Insulation R=0.0 1446.00 ftz b. Conservation features ti.N/A R= ftz None . N/A R= ftz 15.Credits Pstat GII ss/Floor Area: 0.096 Total Proposed Modified Loads: 46.91 PASS Total Baseline Loads: 48.19 I I h reby certify that the plans and specifications covered by Review of the plans and T$E ST. this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance yip ': �_` 0 with the Florida Energy Code. h nrur`!' PREPARED BY: .. Before construction is completed c� DATE: this building will be inspected for 0 94 �I;k'�� y compliance with Section 553.908 I h I reby certify that this building, as designed, is in compliance Florida Statutes. 5� with the Florida Energy Code. -OD Wg'f�� OWNER/AGF,AI,T BUILDING OFFICIAL: DATE: C.o DATE: i - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage teit report in accordance with R402.4.1.2. i, 6%16/2017 11:49 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 'I FORM'R405--2014 PROJECT Title: THE GRAND CARLTON Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot# Owner: Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 135 Street: WYNNE DEVELOPME Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: ST.LUCIE COUNTY Jurisdiction: Whole House Fan: No City,State,Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: I 1 I, CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,ST_LUCIE_CO_INTL FL VERO_BEACH_MUNI 2 39 90 70 75 299 58 Medium I I BLOCKS (Number Name Area Volume I 1 Entire House 1446 11568 SPACES IlNumber Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 234 1872 No 2 1 1 Yes Yes Yes 2 WIC 54 432 No 0 1 No Yes Yes , 3 MASTER BATH 63 504 No 0 1 Yes Yes Yes '14 M. BATH 56 448 No 0 1 Yes Yes Yes l 5 KITCHEN 172 1376 Yes 0 1 No Yes Yes 6 BATH 45 360 No 0 1 Yes Yes Yes 17 BEDROOM 2 204 1632 No 1 1 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 526 4208 No 0 1 Yes Yes Yes 110 FOYER 50 400 No 0 1 Yes Yes Yes I FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio BEDROOM 40 ft 0 234 ftz ____ 0 1 0 I 2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 54 ftz ____ 0 1 0 3 Slab-On-Grade Edge Insulatio MASTER BATH 9 ft 0 63 ftz _-__ 0 1 0 4Slab-On-Grade Edge Insulatio M.BATH 8 ft 0 56 ftZ ____ 0 1 0 1 5 Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 172 ftZ ____ 0 1 0 6 Slab-On-Grade Edge Insulatio BATH 5 ft 0 45 ftz ____ 0 1 0 I' 7SIab-On-Grade Edge Insulatio BEDROOM 2 34.2 ft 0 204 ftZ 0 1 0 I 6/16/2017 11:49 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab-On-Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ---- 0 1 0 9 Siab-On-Grade Edge Insulatio GREAT/DINING 47 ft 0 526 ft2 _--- 0 1 0 10SIab-On-Grade Edge Insulatio FOYER 7 ft 0 50 ft2 --- 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC i # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N 'I i CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) BEDROOM 30 Blown 234 ft2 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 54 ft2 0.1 Wood 3 Under Attic(Vented) MASTER BATH 30 Blown 63 ft2 0.1 Wood 4 Under Attic(Vented) M.BATH 30 Blown 56 ft2 0.1 Wood 5 Under Attic(Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood 6 Under Attic(Vented) BATH 30 Blown 45 ft2 0.1 Wood I 7 Under Attic(Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 8 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood i 9 Under Attic(Vented) GREAT/DINING 30 Blown 526 ft2 0.1 Wood 10 Under Attic(Vented) FOYER 30 Blown 50 ft2 0.1 Wood �I ii i WALLS Adjacent Cavity Width Height AreaSheathinR-Vallleg FramingEmctinn SolarAhSor Below nrntWallType Space rrarle% 1 N=>SE Exterior Concrete Block-Ext Insd9EDROOM 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 2 S=>NW Exterior Concrete Block-Ext InsMEDROOM 4.1 18 0 8 0 144.0 ft2 0 0 0.5 0 3 W=>NE Exterior Concrete Block-Ext InsEEDROOM 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 I 4 S=>NW Exterior Concrete Block-Ext InsMRSTER BA 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 5 S=>NW Exterior Concrete Block-Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 j 6 N=>SE Exterior Concrete Block-Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 7 N=>SE Exterior Concrete Block-Ext IndIffDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.5 0 1 18 E=>SW Exterior Concrete Block-Ext ImBEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.5 0 9 SE=>W Exterior Concrete Block-Ext InREDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.5 0 10 S=>NW Exterior Concrete Block-Ext In§1EDROOM 2 4.1 4 0 8 0 32.0 ft2 0, 0 0.5 0 11 S=>NW Exterior Concrete Block-Ext InSi11AUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0 12 N=>SE Exterior Concrete Block-Ext Ins REAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.5 0 6/1/2017 8:43 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing. Solar Below Spacelle Et Et In Area R-NImille Ahqor _13 W=>NE Exterior Concrete Block-Ext InsGREAT/DINI 4.1 21 0 8 0 168.0 ft2 0 0 0.5 0 14 N=>SE Exterior Concrete Block-Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 15 E=>SW Exterior Concrete Block-Ext Insul FOYER 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0 16 N=>SE Exterior Frame-Wood GREAT/DINI 11 23 5 8 187.3 ft2 0.23 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E=>SW Insulated FOYER None .28 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 W=>NE 3 Metal Low-E Double Yes 0.54 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 it i 2 S=>NW 5 Metal Low-E Double Y 2 Yes 0.54 0.25 6.9 ft 1 ft 0 in 1 ft 4 in None None I 3 E=>SW 8 Metal Low-E Double Yes 0.54 0.25 23.2 ft2 1 ft 0 in 1 ft 4 in None None 4 N=>SE 12 Metal Low-E Double Yes 0.54 0.25 36.8 ft2 1 ft 0 in 1 ft 4 in None None l 5 W=>NE 13 Metal Low-E Double Yes 0.55 0.25 40.0 ft2 10 ft 0 in 1 ft 4 in None None I GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 315ft2 315ft2 24ft 8ft 11 I I INFILTRATION i # Scope Method SLA CFM 50 ELA EgIA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .2455 7 i r HEATING SYSTEM V I # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 it I COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85' 1 sys#1 l I I i 6/,1/2017 8:43 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 �I FORM R405-2014 HOT WATER SYSTEM F # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftZ DUCTS —Supply-- --Return-- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 320 ftZ Attic 80 ftz Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Piogramable Thermostat:Y Ceiling Fans: Coolin [ ]Jan [ ]Feb Mar [ ]Apr [ ]May [X]Jun ri Jul [X]Au ri Se [ ]Oct Nov [ ]Dec Heating [X]Jan [X]Feb Mar [ ]Apr [ ]May [ ]Jun Jul E ]Au SeP [ ]Oct XNov [X]Dec Veintin [ ]Jan [ ]Feb X Mar [X]A r [ ]Ma [ ]Jun Jul ]Aug Se [X]Oct X Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schiedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Col ling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78. PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68. 68 68 .68 68 68 66 66 i I i 6/1/2017 8:43 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 I FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT Street: WYNNE DEVELOPMENT Permit Office: ST. LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number: Owner: Jurisdiction: Design Location: FL,ST_LUCIE_CO_INTL COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. IRim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. i The air barrier shall be installed at any exposed edge of insulation. brawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation. Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air j barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. i .HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. !Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 6/16/2017 11:54 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 ,i FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) S P LAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. WYNNE DEVELOPMENT, FT. PIERCE, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame-Wood, Exterior R=11.0 187.33 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d.N/A R= ft2 5. Is this a worst case? 10.Ceiling Types Insulation Area I Yes a. Under Attic(Vented) R=30.0 1446.00 ft2 6. Conditioned floor area(ft2) 1446 b. N/A R= ft2 it 2 7. Windows- Description Area c.N/A R= ft a. U-Factor: Dbl, U=0.54 99.23 ft2 11.Ducts R ft2 SHGC: SHGC=0.25 a.Sup:Attic, Ret:Attic,AH:Attic 6 320 b. U-Factor: Dbl, U=0.55 40.00 ft2 SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency c: U-Factor: N/A ft2 a.Central Unit 34.8 SEER:15.00 SHGC: d: U-Factor: N/A ft2 j SHGC: 13. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.586 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Airea Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14.Hot water systems 2 a. Electric Cap:40 gallons a;Slab-On-Grade Edge Insulation R=0.0 1446.00 ft EF:0.97 b:N/A R= ft2 c:N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building -O$E S7, Construction through the above energy saving features which will be installed (or exceeded) yy0 = ATAo in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home �'ph City/FL Zip: ✓�,�oD �c,4 ,Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For _information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 611/2017 8:43 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 ° pro ect Summ.a Job: htsofwri Date: Entire House By: QUICK CALCS, INC. 317 ST.'LUCIE LN.,FT.-PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@/\gL.COM Project • • • I� For: THE GRAND CARLTON WYNNE DEVELOPMENT,, FT. PIERCE, FL CA Notes: Design Information Weather Fort Pierce,'FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary. Sensible Cooling Equipment Load Sizing Structure 17848 Btuh Structure 17520 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent(0 cfm): 0 Btuh Central vent(0 cfm) 0 Btuh (none). (none) Humidification 0 Btuh Blower . 0 Btuh Piping, 0 Btuh Equipment load 23503 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 24753 Btuh . j Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average j Fireplaces 0 Structure 3203 Btuh Ducts 2318 Btuh Central vent(0 cfm) 0 Btuh Heatingg cool" (none). Area e( 1446 1446 Equipment latent load 5521 Btuh Volume(ft3) 12511 12511 Air changes/hour 0.45 0.23 Equipment total load 30274 Btuh Equiv.AVF(cfm) 94 48 Req.total capacity. at 0.70 SHR 2.9 ton Heating Equipment Summary . Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model, 25HBC536A"030 Cond 25HBC536A*030 AHRI ref 7914585 Coil F=N(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER - Heating.input Sensible cooling. 24360. Btuh He output- 34600 Btuh @ 470F Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling 34800_ Btuh Actual air flow.. 1160 cfm Actual airflow 116.0. cfm. Air flow factor 0.049 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0:50 in H2O Static pressure 0.50 in H2O Space thermostat. Load sensible heat ratio 0.83- Capacity balance point 32°F Backup: Input=7 kW, -Output=23009 Btuh, 100 AFUE' Calculations approved byACCA to meet all requirements of Manual J 8th Ed. QL - - wrightsoft` 2017-Apr-11 09:29:38 Right-Suite®Universal 2.017 17.0.14 RSU08101,ACCN Page 1 ..uick CalcsMocuments\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N Y f +�+ wrightsoft° Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS @ AOL.COM 1 Room name Entire House BEDROOM 2 .Exposed wall 156.2 ft 49.0 ft 3. Room height 8.7 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 297.0 ft 5 Room area 1445.5 ft2 297.0 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (ftj Load number (Btuh/ftl-"F) (Stuhlft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) . Heat Cool. Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-0acs 0.143 :n -4:00: 2 55 503 465 1862 1184 72 72 :288 183 `4A5 tom, 0.770 ::m' 21 56 . -.19.31 :38 0 815 : 7.30.,.' D: 0 : :0.. 0 11T:l13A4ocs 0.143 a 4.00 2.55 128 83 333 212 0 0 0 0 1Ac1om 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W " 13A4ors 0:143 se. 4:00 255 34' 34 136 66 0 0 0 0: 13A4ocs 0.143 s 4.00 2.55 360 353 1414 899 216 216 865 550 t-G 1Ac1om 1.270 s 35.56 34.77 7 7 247 241 0 0 0 0 13AAocs .0.143 w 4.00 255 310 237 949 603 104 .72: 288 183 1A-c1om 1.270 .w : 35 56, 55.21 32 2 1140 1770 32 2 1140 1770 4A5 tom O:T/0 w 21.56: 19.31 4T 41 880 788 0 0 0 `0 P 12C-Osw. 0.091 - . 2.55 1.28 _ 192 192 489 246 0 0 0 0 C , _16A 30md 0032: 00 232 1446 1446 1295:: 3354'.;:. ­_297.'297 297 266 689 F 22A-tpl 0.9189 - 27.69 0.00 1446 156 4325 0 297 49 1357 0 - 6 c)AED erz�ursion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 3 690 Appliances/other 2000 0 Subtotal(lines 6 to 13) 17848 17520 5M 4925 Less external load 0 0 0 0 Less:transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 5053 4925 15 Duct loads 32% 49% 5654 8536 32% 49% 1601 2400 Total room load 23503 26056 6653 7325 Air required(cfm) 1160 1160 3628 326 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsa. ft• 2017-Apr-11 09:29:38 A& Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N i - wrightsoft' Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@,AOL:COM 1 Room name WIC KrrCHEN 2 Exposed wall O ft O ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 6.0 x 9.0 ft 1.0 x 172.0 ft 5 Room area 54.0 ft2 1720 ftz Ty Construction U-value Or HTM Area (ft2) Load .Area (ft2) Load number (Btuh/ft2L-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Grass N/P/S Heat Cool Gross NOS Heat Cool 6 . 13A-0ocs';' 0,143"-n 4,00: 2.55 0 : .. ,. 0 0 0 0: 0 -0. _ 0. 0:770 n 21:56 -193T 0 0 0 0 0 0.- 0.. 0 13A-4ocs 0.143 a 4.00 2.55 0 . 0 0 0 0 0 6 0 1A-clom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W.. 13A-4ocs 0.143 se._ 4.00 2.55 0 0 0. 0 0 0 0 0 V}1 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 L—G 1A-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A-46cs 0.143 w 4.00. 255' 0 0 0 0 0 0. 0 0 9A-clorn 1.270 w 35.56 55.21 0 0 0 0 0 0 0. 0 4A5 tom. .0.770 .,w 21..56 19:31 0, 0 0 . -0 0 . 0 P 12C-Osw 0.091 2.55 1.28. 0 0 0 0 64 64 163 82 C : 16A-30m0,.., 0.032,:'= 0s90 2;32 54 .. . 54 48;'..: 125 .::. . .172 :`172 :154 399 F 22A-tpl 0.989 27.6.9 0.00 54 0 0 0 172 0 0 0 i 6 c)AED exursion -9 -170 Envelope loss/gain 48 117 317 311 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2000 Subtotal(lines 6 to 13) 48 117 317 2311 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 48 117 317 2311 15 Duct loads 32% 49% 15 57 32% 49%1 100 1126 Total room load 64 174 418 3437 Air required(cfm) 3 81 21 153 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� -Fk- wrigFttsoft- Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 2 297 ..uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N i I , - -wrightsoft Right-J®Worksheet Job: Entire House bate: By: QUICK CALLS, INC. 317 ST.,LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@/\OL.COM 1 Room name BATH BEDROOM 2 • 2 Exposed wall 5.0 ft 34.2 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool j 4 Room dimensions 9.0 x .5.0 ft 1'.0, x 203.5 fit 5 Room area 45.0 ft2 203.5 ft2 Ty Construction U-value. Or HTM Area (ft2) . Load Area. (ft2) Load number (Btuh/ft2L-°F) (Btu 2) or perimeter (ft) (Btuh) or perimeter: (ft) (Btuh) I Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-0ocs' U 143 n 4 00 2 55 40 40 160 102 128 128 513 326; 4A52am>' OJ70 n ,2156 19:39 0 0,., 0 4 13A-4ocs 0.143 a 4.00 2.55 0 0 0. 0 80 56 225 143 1Ac1om 1.270 a 35.56 87.29 0 0 0 0 24 2 848 2082 11 11D0 0.390 a 10.92 11.31 0 .0 0 0 0 0 0, 0 W.. ." "IMAocs: 0143: se :4 00 255 0 0 0 . 0 34 ,34. 136 86 W 13A-0ocs 0143 s 4.00 2.55 0 0 0 0 32 32 128 81 T_C 1Aclom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A-0ocs .0143 w 4 00 2.55 0 0 0 0 0 0 0 0 1A61om 1270 w 3556 5521 0 0 0 0.;- 0 0 0 0 4A5 tom 0 770 .w 21 56 19 31 0 0 0: p p 0 0 ,. 0 P. 12C-0sw- 0,091 - 2.55 1.28 0 0 0 0 0 0 0 0 30md -.`0 032 090 .232 :.. . .'45 45 40 104 204 204 182 472 F 22A tpi 0.989 .27.69 0.00 45 5 138 0 204 34 946 I _ _ l . I 6 c)AED excursion -16 -85 Envelope loss/gain 339 190 2978 3106 12 a), Infiltration . 87 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 b 0 1 230 Appliances/other 0 0 Subtotal Qines 6 to 13) 425 214 3571 3498 Less odemal load 0 0 0 .0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 425 214 3571 3498 15 Duct loads 32% 49% 135 104 320/o 49%1 1131 1704 'I Total room load 560 318 470 5203 j, Air required(cfm) 28 14 23� 232 Calculations approved byACCA to meet all requirements of Manual J.8th Ed. _ I .` wrightsoft' 2017-AQr-1109:29:38 Right-Suite®Universal-2017 17.0.14 RSU08101 Page 3 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Cale=MJ8 Front Door faces: N ! I -r wrightsoft Right-J®Worksheet Job: Entire House °ate` QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 E;q)osed wall 6.0 ft 47.0 ft 3 Room height 8.0 ft heat/cool 9.8 ft heat/cool. 4 Room dimensions 7.0 x 6.0 ft 1.0 x 526.0 ft 5 Room area 42.0 ft2 526.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuhlft2-°F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 13A-flocs- 0:143 n : 400, 255 0 0 0 0 :. 255 217 869 Z52 1--G; ;4A5-2om: 0:770 n 21:56 _ 1931. 0 0 . 0 0 38' :0 5815 730 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 j 11 r-D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W 13A-4ocs, 6.143 se 4.00 255 0 0 0 0 0 0 0 0 V+/ 13A4ocs 0.143 s 4.00 2.55 48 48 192 122 0 0 0 0 G 1Aclom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A4ocs .0.143 w 4.00 2-55 0 0 0 0 206 165 661 420 4. 1A clom 1270 w.: 35:56, 55.21 .0 0 0. 0 0 0` 0 ; 0 s9A5tom: Or770 w 21.56_ 19:31 0 0 0:.' 0. 41 41:. 880... 788 P 12C-Osw 0.091_ - 2.55 1.28 56 56 143_ 72 0 . 0 0 0 C 16A-3001d: -'6.032; ".0.90 -` 2 32 42 42 38' 97::._ : 526 526: 471 1220 F 22A-tpl 0.989 - 27.69 0.06 42 6 166 0 526 47 1302 0 j ,I 6 c)AED excursion -22 668 Envelope loss/gain 539 270 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 .460 Appliances/other 0 0 Subtotal(lines 6 to 13) . 643 298 5994 5112 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 643 298 5994 5112 15 Duct loads 1 32% 49%1 204 145 32% 49%1 1899 2490 1 Total room'load 846 443 1 1 7892 7602 Air required(cfm) 42 20 390 338 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 411- wrightsexft, M17-Apr-11 09:29:38 .4CCA Right-Sulte@ Universal 201717.0.14 RSU08101 Page 4 uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N wrightsoft' Right-. J®Worksheet Job: Entire House Date: QUICK CALLS, INC. By. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS !AOL.COM 1 Room name FOYER M.BATH 2 Exposed wall 7.0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 50.0 ft 7.0 x 8.0 ft 5 Room area 50.0 ft2 56.0 ft2 Ty Construction U-value Or HTM Area (ftq Load Area Load number (Stuhlft7-`F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross NIP/S Heat Cool 6 13A4o6s: ::0143 n . M `2 55 8 8 32` 20 0 0 0 0 r.4Ak6m 0 770 :n 21:56 .19:31 0 0 0 0 0:.. 0 0 0: VL1 13A-4ocs 0.143 a 4.00 2.55 48 27 108 69 0 0 0 0 1A-c1om 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W - 13A-0ocs 0:143 se 4.00 '2.55 0 0 0 0 0 0 0 ,0 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 64 57 228 145 L-G 1Ac1om 1.270 s 35.56 34.77 0 0 0 0 7 7 247 241 13AAocs .0 143 w 4.00, 2.55 0 0 0 0 0 0 .0 0 AA-c1om 1'270 w 3556 5521 0- 0 0 0 0 0. 0 0 4A5 tom 0.770 W. 2156 19:$1 0 0 0 ... 0''. 0" 0 0 0. i _P. 12C-0sw_ -0.091 - 2.55 1.28 72 72 183 92 0 0 0- 0 C ;;;16A-30md- :. . 0 032: 0:90 2.32 50 50 45 116 56 56 50 ;'130 F. 22A41) 0.9.89 - 27.69 0.0o 50 7 194 0 56 8. 222 0 i i .. 61 c)AED excursion -39 -38 Envelope loss/gain 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1 0 Subtotal(lines 6 to 13) 913 529 885 . 516 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 885 516 15 Duct loads 32% 49% 289 258 32%1. 49%1 2801 251 Total room load 1202 787 1166 768 Air required(cfm) 1 1 59 35 58 34 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2017-Apr-11 09:29:38 GP. Right-Suite®Universal 2017 17.0.14 RSU08101 Page 5 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N Duct S stem Summary Job: wrightsoft� Date: Entire House By: QUICK CALCS,INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:.772-466-6799:Fax 772-466-6796 Email:QUICKCALCS AOL.COM Rroject • • For: THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Heating. Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 :in H2O 0.50 in H2O Supply!return available pressure 0.260/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.285 in/100ft 0.285 in/100ft Actual air flow 1160 cfm 1160 cfm Total effective length(TEL) 176 ft SupplyDetail Table !� Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv' Name (Btuh) (cfm) (cfm) FR (in) (in) Matl. Ln (ft) Ln (ft)- Trunk BATH- h 560 28 14 0.364 4.0 Ox 0 VIFx 22.4 115.0 st1 BEDROOM h 4702 232 232 0.360 7.0 ox0 VIFx 23.9 115.0 st1 BEDROOM-A h 3327 164 163 0.300 6.0 ox0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Ox0 VIFx 40.6 135.0 st2 FOYER h 1202 59 35, 0.505 4.0 Ox0 VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 ox0 VIFx 31.8. 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 ox0 VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 ox0 VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 Ox 0 VIFx 23.3 115.0 st1 M.BATH-A h 768 58 34 0 0 Ox0 VIFx 0 0 wlc c 174 3 8 0.309 4.0 Ox 0 VIFx 27.0 135.0 st2 SUPPlY Trunk DetailTable I Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (cfm) FR (fpm) (in) (in) Material Trunk li st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VInIFIx st1 St1 Peak AVF 1043 1091 0.285. 1020 14.0 0 x 0 VinlFlx i ; wrig htsoft° Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38 Z � "f"bv...uick CaIcslDocuments\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N Page 1 i i Return Branch Detail Table Grille Htg Clg . TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fprn). (in) . (in) Opening(in). Matl_ Trunk rb1 Ox0 . 1160 1:160 0 0 0 0 Ox 0 VIFx I I i ,i I i j I I I htSO I'1ft� Page 2 2017-Apr-1109:29:38 W 9 Right-Suite®Universal 2017 17.0.14 RSU08101 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N I