Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutProject Information FORM R405-2014 . •
ENERGY PERFORMANCE LEVEL EPL
DISPLAY CARD i?aq - 02-G9
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
WYNNE DEV., FT. PIERCE, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1448.70 ftz
b.Frame-Wood,Adjacent . R=11.0 240.00 ftz
3. Number of units,if multiple family 1 c. N/A R= ftz
4. Number of Bedrooms 3 d.N/A R= ftz
5. Is this a worst case?
10.CeilingTypes Insulation Area
Yes ypa.Under Attic(Vented) R=30.0 1720.00 ftz
6. Conditioned floor area(ftz) 1720 b.N/A R= ftz
7. Windows- Description Area c. R= ft
z
a. U-Factor: Sgl, U=0.54 115.42 ftz 11.Ducts R ftz
SHGC: SHGC=0.25 a.Sup:Attic, Ret:Attic,AH:Attic 6 325
b. U-Factor: Sgl, U=0.55 40.00 ftz
SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ftz a.Central Unit 34.8 SEER:15.00
SHGC:
d. U-Factor: N/A ftz 13. Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 34.8 HSPF:8.50
Area Weighted Average Overhang Depth: 3.316 ft.
Area Weighted Average SHGC: 0.250
8. Floor Types Insulation Area 14.Hot water systems
Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1720.00 ftz a. EF:0.97
b.N/A R= ftz
c.N/A R= ftz b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building THE Sp
Construction through the above energy saving features which will be installed (or exceeded) A��O
in this home before final inspection. Otherwise a new EPL Display Card will be completed %' r
based on installed Code compliant features.
Builder Signature: . 1 Date:
Address of New Home: �jG' City/FL Zip
WE, o
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/3/2017 3:41 PM i EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
I
< y
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE ROYALE Builder Name: WYNNE
Street: WYNNE DEV. Permit Office: ST.LUCIE COUNTY
City,State,Zip: FT. PI RCE Permit Number:
Owner: e�\JC1 Jurisdiction:
Design Location: FL, Fort Pierce County:: ST. LUCIE COUNTY(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1688.7 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1448.70 ftz
b.Frame-Wood,Adjacent R=11.0 240.00 ftZ
3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 3 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1720.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 1720.00 ftZ
6. Conditioned floor area above grade(ftz) 1720 b. N/A R= ftz
Conditioned floor area below grade(ftz) 0 c.N/A R= ftz
11. Ducts R ftz
7. Windows(155.4 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 325
a. U-Factor: Sgl, U=0.54 115.42 ftz
SHGC: SHGC=0.25
b. U-Factor: Sgl,U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.25 a.Central Unit 34.8 SEER:15.00
c. U-Factor: N/A ftz
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ftz a.Electric Heat Pump 34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.316 ft.
Area Weighted Average SHGC: 0.250 14.Hot water systems
8. Floor Types (1720.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1720.00 ftz b. Conservation features EF:0.970
b. N/A R= ftz None
c. N/A R= ftz 15.Credits Pstat
Glass/Floor Area: 0.090 Total Proposed Modified Loads: 54.94_ PASS
Total Baseline Loads: 56.22
I hereby certify that the plans and specifications covered by Review of the plans and T'BE SSA?$'
this calculation are in compliance with the Florida Energy specifications covered by this z
Code. p
calculation indicates compliance
with the Florida Energy Code. !� nHu` '9• :;_; ;;��"��„�O
PREPAR D BY: Before construction is completed
DATE: -2LI this building will be inspected for I `
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance Florida Statutes.
with the Florida Energy Code. G'Ob WE
OWNER/ NT BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
CONTRACTOR COPY
jl
4/3/2017 3:41 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
RM R405-2014
PROJECT
Title: WYNNE THE ROYALE Bedrooms: 3 Address Type: Street Address
Building Type: User Conditioned Area: 1720 Lot#
Owner: Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: WYNNE Rotate Angle: 135 Street: WYNNE DEV.
Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: ST.LUCIE COUNTY
Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
v Design Location TMY Site Zone 97.6% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Entire House 1720 13760
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 BEDROOM 343 2744 No 0 1 1 Yes Yes Yes
2 WIC 63 504 No 0 1 No Yes Yes
3 M. BATH 56 448 No 0 1 Yes Yes Yes
4 KITCHEN 172 1376 Yes 0 1 No Yes Yes
5 BATH 45 360 No 0 1 Yes Yes Yes
6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes
7 ENTRY 98 784 No 0 1 Yes Yes Yes
8 LAUNDRY 42 336 No 0 1 Yes Yes Yes
9 GREAT/DINING 528 4224 No 0 1 Yes Yes Yes
10 BEDROOM 3 169 1352 No 1 1 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio BEDROOM 52 ft 0 343 ft2 ---- 0 1 0
2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft2 ____ 0 1 0
3 Slab-On-Grade Edge Insulatio M.BATH 8 ft 0 56 ft2 ---- 0 1 0
4 Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 172 ft2 ---- 0 1 0
5 Slab-On-Grade Edge Insulatio BATH 5 ft 0 45 ft2 ____ 0 1 0
6 Slab-On-Grade Edge Insulatio BEDROOM 2 42.6 ft 0 204 ft2 ____ 0 1 0
7 Slab-On-Grade Edge Insulatio ENTRY 6.3 ft 0 98 ft2 ____ 0 1 0
i
it
I ,
4/3/2017 3:41 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
i
P0FRMR4P05 2014
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
8 Slab-On-Grade Edge Insulatio LAUNDRY Eft 0 42 ft2 ---- 0 1 0
9 Slab-On-Grade Edge Insulatio GREAT/DINING 48 ft 0 528 ft2 ---- 0 1 0
10Slab-On-Grade Edge Insulatio BEDROOM 3 13 ft 0 169 ft2 ---- 0 1 0
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or Shed Metal 1813 ft2 286 ft2 Light 0.6 No 0.9 No 0 18.4
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 1720 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) BEDROOM 30 Blown 343 ft2 0.1 Wood
2 Under Attic(Vented) WIC 30 Blown 63 ft2 0.1 Wood
3 Under Attic(Vented) M.BATH 30 Blown 56 ft2 0.1 Wood
4 Under Attic(Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood
5 Under Attic(Vented) BATH 30 Blown 45 ft2 0.1 Wood
6 Under Attic(Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood
7 Under Attic(Vented) ENTRY 30 Blown 98 ft2 0.1 Wood
8 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood
9 Under Attic(Vented) GREAT/DINING 30 Blown 528 ft2 0.1 Wood
10 Under Attic(Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
Ornt In AMA TypeR-Vallle Et In Ft In Area %
1 N=>SE Exterior Concrete Block-Ext InsiREDROOM 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0
2 S=>NW Exterior Concrete Block-Ext InsfilEDROOM 4.1 29 0 8 0 232.0 ft2 0 0 0.5 0
3 W=>NE Exterior Concrete Block-Ext InsiflEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0
4 S=>NW Exterior Concrete Block-Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0
5 N=>SE Exterior Concrete Block-Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0
6 N=>SE Exterior Concrete Block-Ext InQEDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0
7 NE=>S Exterior Concrete Block-Ext InfiffDROOM 2 4.1 2 10 8 0 22.7 ft2 0 0 0.5 0
8 E=>SW Exterior Concrete Block-Ext Ind3EDROOM 2 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0
9 SE=>W Exterior Concrete Block-Ext InQEDROOM 2 4.1 2 10 8 0 22.7 ft2 0 0 0.5 0
_10 S=>NW Exterior Concrete Block-Ext InMEDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0
11 NE=>S Exterior Concrete Block-Ext Insul ENTRY 4.1 1 5 8 0 11.3 ft2 0 0 0.5 0
12 E=>SW Exterior Concrete Block-Ext Insul ENTRY 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0
i
k
4/3/2017 3:41 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
P. RIM R405-2014 -
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
_13 S=>NW Exterior Concrete'Block-Ext InsU1AUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0
14 N=>SE Exterior Concrete Block-Ext InsGREAT/DINT 4.1 28 0 8 0 224.0 ft2 0 0 0.5 0
15 W=>NE Exterior Concrete Block-Ext Insr3REAT/DINT 4.1 20 0 8 0 160.0 ft2 0 0 0.5 0
16 N=>SE Exterior Concrete Block-Ext InfiffDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0
17 N=>SE Garage Frame-Wood BEDROOM 3 11 30 8 240.0 ft2 0.23 0.5 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 E=>SW Insulated ENTRY None .39 3 6 8 20 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 W=>NE 3 Metal Low-E Single Yes 0.54 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5
2 S=>NW 4 Metal Low-E Single Yes 0.54 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in None None
3 E=>SW 8 Metal Low-E Single Yes 0.54 0.25 23.2 ft2 1 ft 0 in 1 ft 4 in None None
4 N=>SE 14 Metal Low-E Single Yes 0.54 0.25 36.8 ft2 1 ft 0 in 1 ft 4 in None None
5 W=>NE 15 Metal Low-E Single Yes 0.55 0.25 40.0 ft2 10 ft 0 in 1 ft 4 in None None
6 N=>SE 16 Metal Low-E Single Yes 0.54 0.25 16.2 ft2 1 ft 0 in 1 ft 4 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 300 ft2 300 ft2 30 ft 8 ft 11
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356 1605.3 88.13 165.74 .2598 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1
' I
4/3/2017 3:41 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
il
R405-2014
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
----Supply---- ---Return--- Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 325 ft2 Attic 85 ft2 Default Leakage Attic (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar A r Ma rj Jun ri
Jul X Au ri
Se Oct Nov Dec
Heatin Jan HFeb Mar f Apr f May Jun Jul AuSep Oct XNov X Dec
Ventin Jan Feb X Mar [X]A r [ Ma JUn Jul [ Aug Se [X Oct X Nov [ Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
i '
4/3/2017 3:41 PM EnergyGauge@)USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE ROYALE Builder Name: WYNNE
Street: WYNNE DEV. Permit Office: ST.LUCIE COUNTY
City,State,Zip: FT.PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL,Fort Pierce
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace i An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
4/3/2017 3:41 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
F, FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
WYNNE DEV., FT. PIERCE, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1448.70 ftz
b.Frame-Wood,Adjacent R=11.0 240.00 ftz
3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 3 d.N/A R= ftz
5. Is this a worst case? Yes 10.Ceiling Types Insulation Area
a.Under Attic(Vented) R=30.0 1720.00 ftz
6. Conditioned floor area(ftz) 1720 b. N/A R= ftz
7. Windows** Description Area c.N/A R= ftz
a. U-Factor: SgI, U=0.54 115.42 ftz 11.Ducts R ftz
SHGC: SHGC=0.25 a.Sup:Attic, Ret:Attic,AH:Attic 6 325
b. U-Factor: SgI,U=0.55 40.00 ftz
SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ftz a.Central Unit 34.8 SEER:15.00
SHGC:
d. U-Factor: N/A ftz
SHGC: 13.Heating systems kBtu/hr Efficiency
a.Electric Heat Pump 34.8 HSPF:8.50
Area Weighted Average Overhang Depth: 3.316 ft.
Area Weighted Average SHGC: 0.250
8. Floor Types Insulation Area 14.Hot water systems
Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1720.00 ftz a. EF:0.97
b.N/A R= ftz
c.N/A R= ftz b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building VE ST
Construction through the above energy saving features which will be installed (or exceeded) �yO�
in this home before final inspection. Otherwise a new EPL Display Card will be completed r
based on installed Code compliant features.
Builder Signature: - Date: rl 0& Ir l^ a
Address of New Home: ��1 City/FL Zip? '��9 �, 5�
GOD
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if'you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
CONTRACTOR Cps�
4/3/2017 3:41 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page f 1
� I�
I P_ wrightsoft Project.Summary Job::
Entire House By:
QUICK CALCS, INC.
317 ST.LUCIELN.,FT.PIERCE,.FL34946,Phona:772-466-6799 Fax 772-466-6796_ Email:_QUICKCALCSgA0L.00M.
Project • •
For. THE ROYALE-
WYYNNNE DEV., FT. PIERCE, FL
Notes:
Design Information
Weather: Fort Pierce, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 42 OF Outside db 90: OF
Inside db 70 OF Inside db 75 OF,
Design TD 28 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture,difference 61 gr/lb
Heating Summary Sensible Cooling Equipment°Load Sizing
Structure 19898 Btuh Structure 18607 Btuh
Ducts 6092 Btuh Ducts 9204 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0: Btuh
none
Humidification 0 Btuh Blower e). 0 Btuh.
Piping 0 Btuh
Equipment load 25990 Btuh Use manufacturer's data n
Rate/swing multiplier 0.95
Infiltration Equipment sensible load 26420 Btuh
-Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2182 Btuh
Ducts 2516 Btuh
Central vent(O cfm) 0 Btuh
Heating Coolingg. (none)
Area(W) 1720 1720 Equipment latent load 4697 Btuh
Volume(ft3) 14231 14231
Air changes/hour 0.38 0.20 Equipment total load 31117 Btuh
Equiv.AVF(cfm) 90 47 Req. total capacity at 0.70 SHR 3.1. ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER AIR CONDITIONING Trade.. CARRIER AIR CONDITIONING
Model 25HBC536A*030 Cond 25HBC536A*030
AHRI ref 7914585 Coil FX4DN(B,F)037
AHRI ref 7914585
Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER
Heating input Sensible cooling 24360- Btuh
Heating output 34600 Btuh @ 47'F Latent cooling 10440 Btuh
Temperature rise 27 OF Total cooling 34800 Btuh
Actual airflow 1160 .cfm Actual air flow .1160. cfm.
Air flow factor 0:045 cfm/Btuh Air flow factor 0.042 cfm/Btuh'
Static pressure 6.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.86
Capacity balance point=35 OF
Backup:
Input=7 kW, . Output=23009 Btah, 100 AFUE
Calculations approved byACCA to meet all requirements of Manual J 8th Ed."
wrightsoft� �®
N E e
- 1 7:29:34®py
Right-Suite®Universal 201717.0.14 RS1108101 e � s � .�
...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc=MJ8 Front Door faces: N ���� �d
it
II
wrightsoft° Right-M Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By:
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772466-6799 Fax 772-466-6796 Email:QUICKCALCS AOL.COM
1 Room name Entire House BEDROOM
2 E)posed wall 180.9 ft 52.0 ft
3 Room height 8.3 ft d 8.0 ft heat/cool
4 Room dimensions 1.0 x 343.0 ft
5 Room area 1719.5 ft' 343.0 ft2
Ty Construction U-value Or HTM Area z (ft2) Load
number Btuh/ft2-°F (Btu 2) or perimeter ft Btuh or( ) ( ) pe ( ) ( ) perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool
6 V 13AAocs 0.143 ri -4.00 2.55 577 524 2096 1333 72 72 288 183
��J--G 1Ac1onn 1:270 - n 35.56 34.77 16 0 565 553 0 0 .0 0
�--G 4A5.2om 0.770 . n 21.56. 19.31 38 0 815 730 0 0 0 i 0
W 13AAocs. 0.143 ne 4.00 2.55 34 34 136 86 0 0 0 0
11j- D 13A-4ocs 0.143 - e 4.00. 2.55 112 67 269 171 0 0 0 0
-G 1Aclonn 1.270 a 35.56 87.29 24 3 848 2082 0 0 0 0
1100 0:390 a 10.92` 11.31 21 - 21 229 238 0 0 0 0
W 13A�4ccs 0.143 se 4.00 2.55 23 23 91 58 0 0 0 0
V�f 13A-0ocs 0:143 s. 4 00 2.55 456 449 1798- 1143 :232 i.- 232. 929' ':591
l- G .1A-c9orn 1.270 <s' 35:56. 34.77 7 14 247 .941 0 0. 0 -'0
13A4ocs 0.143 w 4.00 2.55 290 217 867 551 112 79 318 202
1Aclom 1.270 w 35.56 55.25 33 4 1162 1806 33 2 1162 1806
4A5.2om 0.770 w 21.56 45.63 41 4 880 1862 0 0 0 0
;Pd ]2C-0sw 0.091' - 2.55 1.28: 224 224 - _ 571 267 0.• . • :0 0 0
C 16A-30md 0.032 0.90 2.32 1720 1720 1541 3989 343 343 307 796
f 22A-tpl 0.989 : - 27.69 0.00 1720 181 5010. 0 343 52 1440.; 0
6 c)AED excursion 465 668
Envelope loss/gain 17124 15595 4444 4245
12 a) Infiltration 2774 782 773 218
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 1 230 0 0
Appliances/other 2000 0
Subtotal Qines 6 to 13) 19898 18607 5218 4463
Less extemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 19898 18607 5218 4463
15 Duct loads 31% 49% 6092 9204 31% 49% 1598 2208
Total room load 25990 27810 6815 6671
Air required(cfm) 1160 1160 1 304 278
Calculations approved bVACCA to meet all requirements of Manual J 8th Ed.
- - wrigF�tsoft' 2017-Apr-10 17:29:34
��� Right-Suite®Universal 2017 17.0.14 RSU08101 Page 1
..\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc=MJ8 Front Door faces: N
-wrightsoft' Right-J®Worksheet Job:
Entire House Date:
By.
QUICK CALCS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@,AOL.COM
1 Room name WIC M.BATH
2 Exposed well 0 ft 8.0 ft
3 Room height 8.0 ft heaticool 8.0 ft heat/cool
4 Room dimensions 7.0 x 9.0 ft 7.0 x 8.0 ft
5 Room area 63.0 ft2 56.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load
number (Btuh/W°F) (Btuh/ft') or perimeter (ft) (Btuh) or
perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0
1A-c1om 1:270 n 35.55 34.77 0 0 0 0 0' 0 0 0
4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0
W 13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0
11 13AAccs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0
1A-c1om 1i270- e 3556 87.29 0 0 0 . 0 0. 0 0. 0
11D0 0390 e. 10.92 11:31 0 0 0 0 0 0 0 0
W 13A flocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0
y! 13A-flocs 0.143 s 4.00 .255 0 0 0 0 64 57 228 145
IA-c1om 1.270 : s 35:56 34:77 p p p 0 7 7 247 ,. 241
V�/ 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0
�L--_-(G; IA-c1om 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0
4A5-2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0
t,P.- 12C-0sw. 0.091 :2.55. .. 1.28 0 0 . 0 :0 0 0 0-> 0
C 16A 30md 0.032 - 0.90 2.32 63 63 56 146 56 56 50 130
F 22A tpl 0.989 - 27.69 0.00 63 0 0 0 56 8 222. 0
j.
6 c)AED exursion -10 -39
Envelope lass/gain 56 136 747 477
12 a) Infiltration 0 0 119 34
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 56 136 866 511
Less a#emal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 56 136 866 511
15 Duct loads 31% 49% 17 67 316 49% 265 253
Total room load 74 203 1131 764
Air required(cfm) 3 8 50 32
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
Az= * wrightsoft' Right-Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page 2
...\Quick Calcs\DocumentslWYNNE-ROYALE-REVISED.rup Calc=MA Front Door faces: N
- wrightsoft' RoghW@ Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@,10LCOM
1 Room name KITCHEN BATH
3 �m�wall
height 8.0 ft 0 ft heat/cool 8.0 ft 5.0 ft heat/cool
4 Room dimensions 1.0 x 172.0 ft 9.0 x 5.0 ft
5 Room area 172.0 ft2 45.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area 2Load
number (Stuhlft2-°F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 Tj13A-4ocs 0.143 n. 4.00 2.55 0 0 0 0 40 40 160 102
1A:---1om 1.270 n 35.56 .34.77 0 0 0 0 0 0 0 0
4A5-2om 0.770 : n 21.66. 19.31 0 0 0 0 0 0 0 0
W 13AAocs. 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0
11 . 13AAocs 0.143 a 4.00 2:55 0 0 0 0 0 0 0 0
1A-clom_ 1:270 a 35.56 87.29 0 0 0 0 0 0 0 .0
11DO 0:39D: e 10.92 11.31- 0 0 0 .0 0 0 :0 0
W 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0
13A-4ocs 0:143 -s : 4.00 2.65 0 0 '0 0 0 0: 0 0
1A-clom 1.270. s 35M 34.77 0 0 0. 0 0 0 0 -'0
13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0
1A-clom 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0
r-G 4A-2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0
P > 12CL0sw 0.091 2.55 1--28 64. 64 . 163 82 0 0 0, 0
C 16A-30md 0.032 - 0.90. 2.32 172 172 154 399 45 45 40 104
F.. 22A51pl 0.989 27.69 --0.00 172 0 0 0 45 5_ ' 138 0
A.
6 c)AED excursion -176 -16
Envelope loss/gain 317 305 339 190
12 a) Infiltration 0 0 74 21
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 2000 0
Subtotal(lines 6 to 13) 317 2305 413 211
Less e)demal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 317 2305 413 211
15 Duct loads 31% 49% 97 1140 31% 49% 127 104
Total room load 414 396 540 315
Air required(cfm) 1 18 144 1 241 13
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
.MR. wrightso. . Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page 3
...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Cale=MA Front Door faces: N
wrightsoft° Right-M Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@,AOL.COM
1 Room name BEDROOM 2 ENTRY
2 .Exposed'wall 42.6 ft 6.3 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 1.0 x 204.0 ft 1.0 x 97.5 ft
5 Room area 204.0 ft2 97.5 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area =
number (Btuh/ft2-"F) (Btuh/ft2) or perimeter (ft) (Btuh or (ft) Load
perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6V[tS13A4ocs 0.143 n 4.00 255 112 112 448 285 0 0 0 0
"IA-clom 1:270 n 35.56 34.77 0 0 0 .0 0 0 0 0
4A5-2om 0.770 n 21.56 19.31 0 0 0. 0 0 0 0: 0
W . 13A-4ocs 0.143 ne 4.00 2.55 23 23 91 58 11 11 45 29
11 13A4ocs - 0.143 .e 4.00 -2.55 72 48 193 123 40 19 -76 48
1Ac16m. 1:270 •e 35.56 ' 87.29 24 2 848: .2082 0, 0 0. 0
11130. 0.390 ,.a 10.92 11.31:. 0 0 0 0 21 21 229.- 238
W 13A flocs 0.143 se 4.00 2.55 23 23 91 58 0 0 0 0
y/ 13A-40cs 0.143 s- 4A 2.55 112 112 448 '285.` 0 0. 0 0
L_G .1Ac1om 1.270 's 35:56: - 34.77 6 0 0 0 0 0 0 0
13AAocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0
1A-o1om 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0
4A5-2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0
P ; '12C-0sw 0:091 .2.55 1'28 0 0 0.: 0 104 104 -265 133
C 16A 30md 0.032 - 0.96 2.32 204 204 183 473 98 98 87 226
F. 22A-tpl 6.989° = 27.69 0.00 204 43-. 1179 0 98 6 175 0
6 c)AED excursion -90 -50
Envelope loss/gain 3481 3273 878 625
12 a) Infiltration 634 179 95 27
b) Room ventilation 0 01 0 0
13 Intemal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 4115 3452 974 '651
Less extemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 4115 3452 974 651
15 Duct oa 131% 49% 1260 1708 31% 49% 298 322
Total room load 5376 5159 1272 974
Air required(cfm) 240 215 57 41
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsoft Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page 4
...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Cale=MJ8 Front Door faces: N
-r{ -wrightsoft° Right-M Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name LAUNDRY GREAT/D)NING
2 E)qposed wall 6.0 ft 48.0 ft
3 Room height 8.0 ft heat/cool 8.9 ft heat/cool
4 Room dimensions 7.0 x 6.0 ft 1.0 x 528.0 ft
5 Room area 42.0 ft2 528.0 ft'
Ty Construction U-value Or HTM Area (ft2) (ft') Load
number (Btuh/ft'°F) (Btuh/ft2) or perimeter (ft) (Btuh s) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 Vy 13A-4ocs 0.143 n 4.00 2.55 0 0 0 0 249 211 846 538
1Ac1om 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
4A5.2om 0.770 n 21.56 19.31 0 0 0 0 38 0 815 730
W 13AAocs 0.143 ne 4.00 Z55 0 0 0 0 0 0 0 0
11 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0
T1A-c1om 1.2.70 .e _ 35:56 87.29 0 0 0. 0 ,. 0 0 0 .0
11D0: _ .0.390 ,,e 10.92 f 11.31 0 0 0-, 0 0 . 0 : .0 0
W 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0
13A-0ocs .0.143 s 4 M ' 2.55 48 48_ 192 122 p 0. -0 0
1A-c1om' 1.270 s` 35:56 ' : 34.77 0 0 - :0 0 0 ,0 0 0
UI/ 13AAocs 0.143 w 4.00 2.55 0 0 0 0 178 137 549 349
L�-GG 1A-c1om 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0
4A5-2om 0.770 w 21.56 45.63 0 0 0 0 41 2 880 1862
P .. 12C-0sw 0.091 - -2.55.: _1.28 56 56 - :143' 72 0 0 :o 0
C 16A 30md 0.032 0.90 2.32 42 42 38 97 528 528 473 1225
F 22A-tpl '0:989 : - 27.69 0.00 '42 6 - 166 -0 528 .481 1329 : 0
6 c)AED excursion -22 305
Envelope loss/gain 539 269 4893 5008
12 a) Infiltration 89 25 794 224
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal pins 6 to 13) 628 294 5687 . 5232
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 628 294 5687 5232
151 Duct loads 1 31% 49% 192 146 31% 49% 1741 2588
Total room load 820 440 7428 7821
Air required(cfm) 37 18 332 326
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-Fk wrightsoTt' Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:Page
e 5
...1Quick Calcs\Documents%WYNNE-ROYALE-REVISED.rup Calc=MJ8 Front Door faces: N
- -PIPPP,r-
wrightsoft, Right-J®Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS AOL.COM
1 Room name BEDROOM 3
2 Exposed wall 13.0 ft
3 Room height 8.0 ft heat/cool
4 Room dimensions 13.0 x 13.0 ft
5 Room area 169.0 ft2
Ty Construction Ll-value Or HTM Area (ft-) Load Area Load
number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A4ocs 0.143 n 4.00 2.65 104 88 353 224
IA-c1om .1.270 n 35.56 34.77 16 0 565 553
4A5-2om 0.770 n 21.56. 19.31 0 0 0. 0
W 13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0
11 13A-06cs_ 0:143 -e 4.00 2.55 0 0 0 0
1A,c1om.. 1:270 a 35.56 87,29 0 0 0 0
11D0 0.390 'e 10:92: 11.31 0 0 0' p
W 13A4ocs 0.143 se 4.00 2.55 0 0 0 0
.13AAdcs :0.143-. s:, 4.00- 2.65 0 0 0 0.
L,-G 1Ac1om '- 1.270 s 35.56 34.77 0 0 0 .0
13A4ocs 0.143 w 4.00 2.55 0 0 0 0
-G 1A-clom 1.270 w 35.56 55.25 0 0 0 0
�-G 4A5.2om 0.770 w 21.56 45.63 0 0 0 0
P 12C 0-s 0:091 Z55 1.28 0 0 0:: 0
C 16A 30md _ 0.032 0.90 2.32 160 169 151 392
F' 22Afpl. 0.989 :: 2769 0.00 169 13 -360 0
i
6 c)AED excursion -103
Envelope loss/gain 1430 1066
12 a) Infiltration 193 55
b) Room ventilation 0 0
13 Internal gains: Occupants @ 230 1 230
Appliances/other 0
Subtotal(lines 6 to 13) 1623 1351
Less extemal load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 1623 1351
15 Duct loads 131% 49%1 497 668
Total room load 2120 2019
Air required(cfm) 95 84
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
- - wrightsoft' 2017-Apr-1017:29:34
. A Rig ht-Suite®Universal 2017 17.0.14 RSU08101 Page 6
...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc=MJ8 Front Door faces: N
Duct-S stem Summary. -�- wrightsoft y Date:
Entire House By:
QUICK CALCS,INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-46"799-Fax 772-466-6796 Email:QUICKCALCS ,AOL.COM
Project • •
For: THE ROYALE
WYNNE DEV., FT. PIERCE, FL
i,
Heating Cooling
External static pressure 0.50 in H2O 0.50 in H2O
Pressure losses 0 in H2O 0 in H2O
Available static pressure 0.50 in H2O 0.50 in H2O
Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O
Lowest friction rate 0.286 in/100ft 0.286 in/100ft
Actual air flow 1160 cfm 1160 cfm
Total effective length(TEL) 175 ft
SupplyDetail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln (ft) Ln (ft) Trunk
BATH h 540 24 13 0.351 4.0 Ox0 VIFx 27.3 115.0 st1
BEDROOM h 3408 152 139 0.286 7.0 OxO VIFx 40.1 135.0 st2
BEDROOM 2 h 5376 240 215 0.343 7.0 OxO, VIFx 30.8 115.0 st1
BEDROOM 3 h MG 95 84 0.371 6.0 OxO VIFx 19.9 115.0 st1
BEDROOM-A h 3408 152 139 0.297 7.0 ox0 VIFx 33.1 135.0 st2'
ENTRY h 1272 57 41 0.485. 4.0 Ox0 VIFx 8.1 95.0
GREAT/DINING-A h 3714 166 163 0.300 7.0 Ox0 VIFx 31.7 135.0 st2
GREAT/DINING-B h 3714 166 163 0.309 7.0 Ox0 VIFx 27.1 .135.0 st2
KITCHEN c 3446 18 144 0.376 7.0 Ox0 VIFx 18.1 115..0 st1
LAUNDRY h 820 37 18 0.369 4.0 ox0 VIFx 20.4 115.0 st1
M.BATH h 1131 50 32 0.366 4.0 OxO VIFx 21.6 115.0 st1
wlc c 203 3 8 0.309 4.0 Ox0 VIFx 26.6 135.0 st2
Supply Trunk Detail • -
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
st2 PeakAVF 639 613 0.286 814 12:0 0 x 0 VinlFlx st1
st1_ PeakAVF 1103 11% 0.286 802 16.0 0 x 0 VinlFlx
t wri htsoft` 2017-Apr-1017:29:35
�, f 9 RightSuite®Universal 2017 17.0.14 RSU08101 Page 1
/ �i� = _...\Quick Calcs\Documents\WYNNEIROYALE REVISED.rup Cale MJ8 Front Door faces: N
MEN
Grille . Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk
rb1 ox0 1160 1160 0 0 0 0 Ox 0 VIFx
1 wri htsoft° 2017-Apr-10 17:29:35
9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2
...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc=MJ8 Front Door faces: N