Loading...
HomeMy WebLinkAboutEngineering Waterbody: Artificial canal off of the Indian River Width: varies 145'+ Proposed Boat Lift 12'-6" 12'.6" Proposed Dock Dock Area over MHW: ,- 78 sq.ft. -v 13 C rvlHWIMLW � r 'o Existing Pp Concrete �D} Seawall �. 0. 10, 20, 7 Scale A White Residence 10701 S. Ocean Dr., Lot 672 Jensen Beach, FL 34957 Proposed White Residence Proposed Wilco Construction, Inc. Date: 4/13 7 Plan View Dock/Boat Lift (772)460-6928;FAX(772)460-6929 ����I111111/�fj ` • -CEti �F N � 1 Dan tj1 Ret rd, P.E.A7D4§1 �13 , S7ATF OF o 1402/�� tab r� ' C '" ��PY 0 Pilings: TYPICAL DOCK AND ACCESSWAY CROSS SECTION min. 8"0, 2.5 CCA (N.T.S.) PT wood, max. 10'OC The work specified herein has been designed and all work shall be in accordance with the 2014 Florida Width:Varies Building Code(5th Ed., First Printing March 2015). All codes reference herein are per the latest adopted edition. Decking: 2"x6"0.4 ACQ#1 Dense Pine fastened w/min. 3" stainless steel screws STRINGERS: 2"x8"0.4 or 0.6 ACQ spaced at max.24"with min. 1/2"SS lag bolts on each piling (lap spliced) • Blocks: 2"x6"xl2"0.4 ACQ strap Joist: blocks @mid stringers 2"x8"0.4 ACQ on (fastened w/min. 3 ea. each side of piling. min. 3"SS screws/nails) Bolted w/5/8" SS cut rods. M.H.W. 1111 I i//! M.L.W. '•y (� WNW�ul e , IS"A 1jj CANAL BOTTOM - == 6'min. penetration bW +atrtm 4� Fqtf PCe&fL 34W7oo- Wood Decking C ! RCS m C Cross View TV o Structural ENGINEERING REVIEW. BOAT LIFT TOP CARRIER BEAMS AND NOTE TO EXAMINER MOUNTING BRACKETS COMPLY2 THIS CERTIFIED ENGINEERED WITH WIND LOAD REQUIREMENTS OF THE FLORIDARAWING HAS BEEN PREPARED SPECInCALLY FOR USE ONLY BY- DESIGN CODE 7, PER PER ASCE AND PER DESIGN LOAD REQUIREMENTS OF THE 2010 ALUMINUM ASSOCIATIONS DESIGN MANUAL. BEAMS AND MOUNTING BRACKETS �•4 EXCEEDINSTALLEULTMATE DESGNSWIND SPEEDWOF o°°°°pppDp°M°p0p�O0o 180 MPH (EXPOSURE CATEGORY C OR D) °o°° R � ,% BOATS ARE TO BE REMOVED FROM BOAT a° O C E IV e° O V � o LIFTS PRIOR TO A MAJOR WND EVENT. e Q N0.4965b e D P e ` P e e 0 Po O 1� 1�'IC OF ��ee l Q� PILINGS R 1 C PENETRATION TO B£ f0' °00��3 0 PILING �? INTO THE SAND BOTTOM OR 5' . ooOOoos1 ONA1. IN TO R 0 C K S T R A TA , SUB—SURFACE CONDITIONS CAN VARY GREATLY, THE CONTRACTOR SHALL VERIFY ALL PILE CAPACITIES TO COMPLY WITH FBC 2014. ALL PILINGS TO BE ROGER BAKER 8" MINIMUM DIAMETER P.E. N0. 43 EN MCR PROFESSIONAL GINEERING EN 2.5 C.C.A PRESSURE TREATED C.A. NO. 26967 WOOD, PRE—STRESSED CONCRETE 1014 NW PINELAKE DR. OR COMPARABLE EQUIVALENT. STUART FL 34994 PILING MOUNTING TABS MINIMUM (2) 3/8" D/A. SS LAG BOL TS FOR WOOD PILING OR SS CONCRETE ANCHORS FOR ELECTRICAL REVIEW. CONCRETE PILINGS PER PILING 3/4 HP ELECTRIC MOTOR REQUIRED.M/N/MUM (2) 3/8" 10.8 AMPS 0 115V EACH DIA. SS CARRIAGE BOLT FOR 5.4 AMPS 0 230V EACH ATTACHING MOUNTING TAB TO QUAN7ITY.• 2 LIFT REQUIRED PER PILING. TOTAL WATTS.• 2484 MOUNTING TAB CONSTRUCTED FROM 1/4" X 2" ALUMINUM 6 0 6 1 — T 6 FLA T BAR. f? w f0 LItTL!! Y WV0 DUAWS 1 E » F 72,000 LB. CUDA GEAR BOATLIFTS AND MARINE PRODUCTS 3 4 AL 9° Y f BOA T LIFT 4050 SELV/TZ ROAD a s uNmf. s ll( ( FORT PIERCE, FL 34981 s MVE GEAR1 R. HYDE SCALE. NTS DATE. 1/3/17 REV 1 1-800-544-0735 www.hi—tide.corn ncscYrrna