HomeMy WebLinkAbout2012IRCVentilationRequirements(2), 3.1.21INTERNATIONAL RESIDENTIAL CODE MECHANICAL VENTILATION AS REQUIRED BY IOWA 2012 IECC SECTION 403.5 DEFINITIONS LOCAL EXHAUST. An exhaust system that uses one or more fans to exhaust air from a specific room or rooms within a dwelling. WHOLE HOUSE MECHANICAL VENTILATION SYSTEM. An exhaust system, supply system, or combination thereof that is designed to mechanically exchange indoor air with outdoor air when operating continuously or through a programmed intermittent schedule to satisfy the whole house ventilation rates. SECTION M1507 MECHANICAL VENTILATION M1507.1 General. Where local exhaust or whole-house mechanical ventilation is provided, the equipment shall be designed in accordance with this section. M1507.2 Recirculation of air. Exhaust air from bathrooms and toilet rooms shall not be recirculated within a residence or to another dwelling unit and shall be exhausted directly to the outdoors. Exhaust air from bathrooms and toilet rooms shall not discharge into an attic, crawl space or other areas inside the building. M1507.3 Whole-house mechanical ventilation system. Whole-house mechanical ventilation systems shall be designed in accordance with Sections M1507.3.1 through M1507.3.3. M1507.3.1 System design. The whole-house ventilation system shall consist of one or more supply or exhaust fans, or a combination of such, and associated ducts and controls. Local exhaust or supply fans are permitted to serve as such a system. Outdoor air ducts connected to the return side of an air handler shall be considered to provide supply ventilation. M1507.3.2 System controls. The whole-house mechanical ventilation system shall be provided with controls that enable manual override. M1507.3.3 Mechanical ventilation rate. The whole house mechanical ventilation system shall provide outdoor air at a continuous rate of not less than that determined in accordance with Table M1507.3.3(1). Exception: The whole-house mechanical ventilation system is permitted to operate intermittently where the system has controls that enable operation for not less than 25-percent of each 4-hour segment and the ventilation rate prescribed in Table M1507.3.3(1) is multiplied by the factor determined in accordance with Table M1507.3.3(2). M1507.4 Local exhaust rates. Local exhaust systems shall be designed to have the capacity to exhaust the minimum air flow rate determined in accordance with Table M1507.4. TABLE M1507.4 MINIMUM REQUIRED LOCAL EXHAUST RATES FOR ONE- AND TWO-FAMILY DWELLINGS AREA TO BE EXHAUSTED EXHAUST RATES Kitchens 100 cfm intermittent or 25 cfm continuous Bathrooms—Toilet Rooms Mechanical exhaust capacity of 50 cfm intermittent or 20 cfm continuous For SI: 1 cubic foot per minute = 0.4719 L/s. TABLE M1507.3.3(1) CONTINUOUS WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM AIR FLOW RATE REQUIREMENTS DWELLING UNIT FLOOR AREA (square feet) NUMBER OF BEDROOMS 0 - 1 2 - 3 4 - 5 6 - 7 >7 Airflow in CFM <1500 30 45 60 75 90 1501-3000 45 60 75 90 105 3001-4500 60 75 90 105 120 4501-6000 75 90 105 120 135 6001-7500 90 105 120 135 150 >7500 105 120 135 150 165 TABLE M1507.3.3(2) INTERMITTENT WHOLE-HOUSE MECHANICAL VENTILATION RATE FACTORSa, b RUN-TIME PERCENTAGE IN EACH 4 HOUR SEGMENT 25% 33% 50% 66% 75% 100% Factora 4 3 2 1.5 1.3 1.0 a. For ventilation system run time values between those given, the factors are permitted to be determined by interpolation. b. Extrapolation beyond the table is prohibited.