Loading...
HomeMy WebLinkAboutBuilding PlansGENERAL NOTES DESIGN CRITERIA: APPLICABLE CODES, REGULATIONS & STANDARDS: 1. THE 2020 FLORIDA BUILDING CODE, 7TH EDITION SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM 2. ASCE 7-10 & SE17 3. AC1318 CONCRETE REFRENCE MANUAL. 4. AA ASM 35 & AA ADM 1 5. AAF GUIDE TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS. WIND LOADS: 1. FBC TABLE 1604.5, RISK CATEGORY = 1 2. FBC SEC 1609.4, EXPOSURE CATEGORY = B 3. FBC SEC 1609.3, ULTIMATE DESIGN WIND SPEED = 150 MPH DESIGN NOTES: ALLOWABLE DESIGN PRESSURES UTILIZED IN THIS DOCUMENT HAVE BEEN CALCULATED PER THE REQUIREMENTS OF THE FLORIDA BUILDING CODE 7TH EDITION (2020) & ASIDE 7-10 USING ALLOWABLE STRESS DESIGN METHODOLOGY WITH THE CRITERIA AS OUTLINED HEREIN. THE CONTRACTOR SHALL CONTACT THE AUTHORITY HAVING JURISDICTION TO ENSURE APPROPRIATE CRITERIA TO BE USED BEFORE CONSTRUCTION BEGINS. THE SYSTEM HAS NOT BEEN DESIGNED TO WITHSTAND CONCETRATED LOADS FROM HUMAN ACTIVITY. DRAWING INDEX SHEET NO. DESCRIPTION G01 GENERAL NOTES S01 STRUCTURAL PLAN F01 FOUNDATION PLAN D01 ROOF &PROJECTION BEAM DETAILS D02 POST & MAIN BEAM DETAILS GENERAL NOTES: 1. THIS DOCUMENT SHALL NOT BE USED OR REPRODUCED WITHOUT THE ORIGINAL SIGNATURE & RAISED SEAL OF-CRAIGE. GUNDERSON, P.E. ALTERATIONS, ADDITIONS OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. PHOTOCOPIES AND UNSEALED DOCUMENTS ARE NOT TO BE ACCEPTED. 2. THIS STRUCTURE HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE STRUCTURAL PROVISIONS OF THE FLORIDA BUILDING CODE SEVENTH EDITION (2020). STRUCTURE SHALL BE FABRICATED IN ACCORDANCE WITH ALL GOVERNING CODES. CONTRACTOR SHALL INVESTIGATE AND CONFORM TO ALL LOCAL BUILDING CODE AMENDMENTS WHICH MAY APPLY AND GOVERN. DESIGN CRITERIA OR SPANS BEYOND STATED HEREIN MAY REQUIRE ADDITIONAL SITE SPECIFIC SEALED ENGINEERING. 3. NO 33-1/3% INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THE DESIGN OF THIS SYSTEM. WIND LOAD DURATION FACTOR Cd=1.6 HAS BEEN USED FOR WOOD ANCHOR DESIGN. 4. THE ARCHITECT/ENGINEER OF RECORD"FOR THE PROJECT SUPERSTRUCTURE WITH WHICH THIS DESIGN IS USED SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE PERMITTING CONTRACTOR. 5. THE CONTRACTOR SHALL CAREFULLY CONSIDER POSSIBLE IMPOSING LOADS ON ROOF, INCLUDING BUT NOT LIMITED TO ANY CONCENTRATED LOADS WHICH MAY JUSTIFY GREATER DESIGN CRITERIA. THIS ADDITIONAL ROOF LOAD CRITERIA SHALL BE PROPERLY ANALYZED BY A LICENSED ENGINEER OR REGISTERED ARCHITECT. 6. ALL FASTENERS TO BE #12 SAE GRADE 2 OR STAINLESS STEEL 304 UNLESS NOTED OTHERWISE. FASTENERS SHALL BE CADMIUM -PLATED OR OTHERWISE CORROSION -RESISTANT MATERIAL AND SHALL COMPLY WITH "SPECIFICATIONS FOR ALUMINUM STRUCTURES" BY THE ALUMINUM ASSOCIATION, INC., & ANY APPLICABLE FEDERAL, STATE, AND/OR LOCAL CODES. 7. FOR ALUMINUM MEMBERS ALL ANCHORS SHALL BE SPACED WITH 2xDIAMETER END DISTANCE AND 2.5xDIAMETER MIN. SPACING TO ADJACENT ANCHORS, UNLESS NOTED OTHERWISE. 8. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. MINIMUM EMBEDMENT SHALL BE AS NOTED HEREIN. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDES STUCCO, FOAM, BRICK, AND OTHER WALL FINISHES. 9. ALL CONCRETE ANCHORS SHALL BE INSTALLED TO NON -CRACKED CONCRETE ONLY. 10. WOOD HOST STRUCTURE & ALL WOOD MEMBERS SHALL BE "SOUTHERN YELLOW PINE" G=0.55 OR GREATER DENSITY. 11. THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALL MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS. 12. ALL ALUMINUM SHALL BE 6005-T5 ALLOY AND TEMPER UNLESS NOTED OTHERWISE. 13. ALL STEEL ANGLES SHALL BE ASTM A1011 OR A653 GRADE 50 (Fy=50 KSI, Fu=65 KSI) OR BETTER. 14. ALL CONCRETE AND EPDXY TO REACH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI IN 7 DAYS. 15. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, & CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 16. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. 17. ALTERATIONS, ADDITIONS, HIGHLIGHTING, OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE THIS CERTIFICATION. SYSTEM NOTES: PERGOLA SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATION ISSUED BY RENAISSANCE PATIO. REFER TO AFOREMENTIONED MANUFACTURER ISSUED ASSEMBLY MANUAL FOR U � J N LO RECEIVED �_ co JAN 2® 1021 z z p o °ermictin St. Lucie De LLI00 O U LLI � EL Ln . z ~_ LLI � N M ` z:20� LL.I 0�0 Q Q 2 U H 0 Q LL ALL CONNECTION DETAILS THAT ARE NOT ILLUSTRATED HEREIN. 1101— 03"/ REVIEWED ED FOR CODE COMPLIANCE ST. LUCiEPi C®UNT BOCC O O _j U LL w Ow Z _ U U) W Z 1D < w J H < U) U) CO o ¢ ��� d Q w O O w U d DESIGN DATE: 01/11/2021 REVISION 1: DATE PAGE: G01 REVISION 2: DATE SCALE: NTS -81-611 1X2 2X2 DJ 0 N �+ 2X2 DJ N X N POST 2'-0" 8'-0" - NJ X N X O cn 0 m 0 G) m W m D a RENAISSANCE CONTEMPO PATIO COVER CONFIGURATION 1 SEE PAGE F01 FOR CONCRETE PLAN HOST BLOCK WALL Q w m w U W O 0 X N X N PROJECTION BEAMS ENDS AT 24" O.C. MAIN BEAM MAIN BEAM 0 m N 0- N 0 O 2X2 2X2 2X2 2X2 N Do 1X2 1X2 1X2 1X2 7'-6" 7'-6" —)-� 7'-6" 7'-611 30'-0" 81-611 1X2 X N 2X2 DJ j 0 N 2X2 DJ N N N cX-I POST REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC CONFIGURATION DESIGNATION POST POST INSERT MAIN BEAM BEAM INSERT 1 SD post and beam system 3.875"X3.875"X0.090" NONE 2.75"X7.00"X0.080" NONE 2 SD post and beam system with beam insert 3.875"X3.875"X0.090" NONE 2.75"X7.00"X0.080" 1-2.464"X6.777" 3 HD post & beam system 3.875"X3.875"X0.188" NONE 2.75"X7.00"X0.125" NONE 4 WD post & beam system 6.00"X6.00"X0.125" NONE 4.875"X7.00"X0.125" NONE 5 WD post & beams stem with post & beam inserts 6.00"X6.00"X0.125" 5.368"X5.368"X0.125" 4.875"X7.00"X0.125" 1-4.589"X6.777" \ \O\ %Xj111111�1,////' / N \\\\\ O� N LL Q LLI O O p'• J L N (ui (o Q z= N 0 CUD o /'/� I I I 1111100� SEE SECTION DETAILS ON PAGES D01 & D02 RECEIVING CHANNEL WITH #12 SELF DRILLING SCREW @ 8" O.C. 1" FROM ENDS TOP & BOTTOM OR EITHER SIDE WITH SCREW THROUGH ENTIRE STRUCTURAL PANEL, TYP. INSULATED PANEL PER SEPERATE CERTIFICATION, TYP. WOOD FASCIA 1 HOST CONNECTION 3A HOST STRUCTURE WITH BUILT-IN FASCIA (BY OTHERS), TYP. (1) 1/4" DIA. WOOD SCREW SPACED 1" MIN., WITYH 1.5" THREAD PENETRATION MIN. & 1" EDGE DISTANCE @ EVERY 12" O.C, TYP. ATTACH TO CARRY BEAM W/ #12 SELF -DRILLING SCREW W/ 1" OD WASHER STRUCTURAL PROJECTION @6" O.C, TYP. INSULATED PANEL INTERIOR CLIP PER SEPERATE CERTIFICATION, TYP. ; SCALLOP PROJECTION •o C 0 INTERIOR CLIP ATTACH USING (2) #14 SELF -DRILLING o SCREW, TYP. p PROJECTION BEAM- MAIN ENDS BEAM (4) #14 SELF -DRILLING POST SCREW PER SIDE, TYP. TRELLIS/ PROJECTION 3 & POST CONNECTION 3A RECEIVING CHANNEL WITH #12 SELF DRILLING SCREW @ 8" O.C. 1" FROM ENDS TOP & BOTTOM OR EITHER SIDE WITH SCREWHR TOUGH ENTIRE STRUCTURAL PANEL, TYP. (1) 1/4" DIA. TAPCON WITH INSULATED PANEL 2.5" EMBEDMENT INTO 3KSI PER SEPERATE OR GROUT FILLED CELLS WITH CERTIFICATION, TYP. p p 5" MIN SPACING & 6" EDGE p a DISTANCE @ 24" O.C, TYP. p EXISTING p CONCRETE OR CBS p pp. WALL, TYP. p a F� 216 'jM 0.070 3" ROOF REC CHANNEL p p p HOST CONNECTION 2 (CONCRETE OR BLOCK) 3A 2" PROJECTION BEAM (TRUSS BEAM) 0.070 8 PROJECTION BEAM INTERIOR CLIP \\0I1111111111///��// Z C ww J ,y > z u REVIEWED FOR CODE COMPLIANCE S` . LUCIE COUNTY B®CC N O O W a 0 m a 0 W 12" MAX, TYP. 1.5" MAX (4) #14 SELF DRILLING SCREW PER SIDE, TYP. :Fmang- _i:: ATTACH TO CARRY BEAM W/ #12 SELF -DRILLING SCREW W/ 1" OD WASHER @6" O.C, TYP. POST CAP MAIN BEAM \_SD BEAM INTERIOR CLIP SD POST 1 SD BEAM TO POST 3B CONNECTION �co 0.12 N 216„ SD BEAM INTERIOR CLIP Lo ~ o 0R 0 Cl) Lo 0 Lo 0.090 ri 1 2.875 1 Lo 0.125 Lo N 2.059 SD POST CLIP 2.750 SD MAIN BEAM SLIDE BASE PLATE COVER OVER POST & BASE PLATE 04T(OPTIONAL) 2 POST EMBEDMENT 3B 0.125 2.464 SD MAIN BEAM INSERT REBAR 12" LONG ROUGH POST, TYP. Lo P05 BASE PL ,vl \\\\\\��11111111/�//////// i o co o LL Ld O w N :w co_ Q U' Z _ 0 E N �i 6' '• ........... ui IP000��\\\\ U o SLIDE BASE PLATE COVER OVER POST & BASE PLATE 4) #14 SELF DRILLING ')CREW PER SIDE, TYP. (6) CONCRETE ANCHORS (SEE PAGE 4) POST 3 ANCHOR CONNECTION 3B 316 1„ EVIEWE® FOR SD BASE PLATE E COMPLIANCEO S N c LUCIE COUN ■ 9 F Z BOCC o U v- J O N Lo _I rn UI co Z Z ap oU LL O U_ W _J 000 W < LL Lo z OIfLLI ' O N N o — W Q -1 ' N 0 U O 0 J T— LL N 00 11, w U U N O ti 0 O N ~ _I UU- Ow_ WV ZD c.0 J � Qco OW C�Lu ~ 00 W O�aa- DESIGN DATE: 01/11/2021 POST & MAIN BEAM DETAILS REVISION 1: DATE PAGE: REVISION 2: DATE DO: (TO BE USED WITH CONFIGURATIONS 1 & 2) SCALE: NTS POST BASE ANCHOR TIE - DOWN SCHEDULES: ANCHOR TYPES: (6) 1/4" DIA ITW TAPCON, 1/4" DIA. SAE ANCHOR TYPE #1 GRADE WASHER, 1.75" EMBEDMENT, 2.5" SPACING, 3" MIN. EDGE DISTANCE INTO 3KSI MIN. CONCRETE (6) 1/4" DIA BLUE TAP ANCHOR WITH 2.1" ANCHOR TYPE #2 EMBEDMENT, INTO 3KSI MIN. CONCRETE 2.5" SPACING, 3" MIN. EDGE DISTANCE 1" 2 5" 38 1 ANCHOR SCHEDULE 4 SCALE: N. T. S 1" z 2 ANCHORS TO BASE PLATE 4 SCALE: N. T. S " NEW 4" SLAB 3000 PSI MIN. " W/ FIBERMESH ;;� o 8"X8" FOOTER 15' —0" 15' —0" 30'-0" O SODDED GRADE CONCRETE PLAN NEW 4" SLAB 3000 PSI W/ FIBERMESH d < a d° G° 45° (1) #5 BAR 8" CONTINUOUS •4[/ Off: N _= Z:Z o LL 0 CUO ......PROF /1111111111 FOOTING NOTES 1. PROVIDE 1-1/2' COVERAGE TOP, SIDES, BOTTOM AND 1" BETWEEN ADJACENT REBAR LAPS. 2. PROVIDE MIN. 3" COVERAGE OF REBAR FOR ALL CONCRETE IN CONTACT WITH THE EARTH. 3. FOOTING CONCRETE SHALL BE MIN. 3000 PSI AT 28 DAYS 4. FOOTING REINFORCEMENT SHALL BE MIN. GRADE 60 5. PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURE TO CITY / CO. REQUIREMENTS 6. PROVIDE 2500 PSF BEARING (TYPICAL) UNDER FOUNDATION 7. SEE GENERAL NOTES FOR TYING INTO EXISTING FOUNDATIONS 8. SEE GENERAL NOTES FOR ADDITIONAL CONCRETE INFORMATION & SPECS. REVIEWED FOR 8"x8" MONOLITHIC FOOTING CODE COMPLIANCE SCALE: NTS ST. LUCIE COUNTY Bocc N O O O w c 0 a) a c� w rn E2 U