HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business .and Professional Regulation - Residential Performance Method
ProjectName: WYNNE THE WINDSOR IMPACT
Street: 3-1 �% ,S �-e\
BuilderName: WYNNE DEVELOPMENT
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
PermitNumber:
Owner:
Jurisdiction:
DesignLocation: FL, Fort Pierce
County. St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1432.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- Int Insul, Exterior
R=4.1 1224.00 ft2
b. Frame - Wood, Adjacent
R=11.0 208.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1783.0 sqft.)
Insulation Area
a. UnderAttic (Vented)
R=30.0 1753.00 ft2
6. Conditioned floorarea above grade (ft2) 1753
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floorarea belowgrade (ft2) 0
c. N/A
R= ft2
11. Ducts -
R ft2
7. Windows(151.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U-Factor: Sgl, U=1.04 111.$6 ft2
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.850 ft.
Area Weighted Average SHGC: 0.285
14. Hot water systems
8. Floor Types (1753.0 sqft.) Insulation Area
a. Electric
Cap: 50 gallons
a. a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 52.17
Glass/Floor Area: 0.086
PASS
Total Baseline Loads: 53.92
hereby certify that the plans and specifications covered by
Review of the plans and,
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPAR€p 3Y. _ -
Before construction is completed
DATE: 4-211 m2
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
With the Florida Energy C
OWNER/AG N�
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection. Checklist -in accordance with R402.4.1.1 and this project requires
an envelope leakage4est report with envelope leakage no greater than 5.0t 5QI(C3 Q � -
CODE CW^MPLIA IN'1+CF:
FILEY y
ST® Ll,1GIE CO�N��
4/21/202010:04 AM EnergyGaugeO USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017 rh9nroftware Page 1 of 6
FORM R405-2017 INPUT.SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE WINDSOR IMP
Bedrooms: 3
Address Type:
Street Address
Building Type: User
ConditionedArea: 1753
Lot#
OwnerName:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
BuilderName: WYNNE DEVELOPMENT
RotateAngle: 0
Street:
Permit Office: ST. LUCIE COUNTY
CrossVentilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: " No
City, State, Zip:
FT. PIERCE,
FamilyType: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
DesignTemp
IntDesignTemp
Heating
Design DailyTemp
V Design Location TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name Area
Volume
1 Entire House 1753
14024
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 MASTER BEDROO 224
1792 No
0
1
1
Yes
Yes
Yes
2 WIC 63
504 No
0
1
No
Yes
Yes
3 MASTER BATH 56
448 No
0
1
Yes
Yes
Yes
4 M.BATH 61
488 No
0
1
Yes
Yes
Yes
5 LAUDRY 36
288 No
0
1
No
Yes
Yes
6 BEDROOM 2 180
1440 No
0'
1
1
Yes
Yes
Yes
7 DINING/GREAT RO 588
4704 No
2
1
Yes
Yes
Yes
8 KITCHEN 209.
1672 Yes
0
1
Yes
Yes
Yes
9 BATH 50
400 No
0
1
Yes
Yes
Yes
10 HALL 25
200 No
0
1
No
Yes
Yes
11 FOYER 92
736 No
0
1
Yes
Yes
Yes
12 BEDROOM 3 169
1352 No
0
1
1
Yes
Yes
Yes
FLOORS
# FloorType Space
Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation MASTER
BEDRO 37 ft 0
224 ft2
----
0 1
0
2Slab-On-Grade Edge Insulation WIC
1 ft 0
63ft2
__-_
0 1
0
3 Slab -On -Grade Edge Insulation MASTER BATH 8 ft 0
56 ft2
-_--
0 1
0
4 Slab -On -Grade Edge Insulation M. BATH 7 ft 0
61 ft2
----
0 1
0
5Slab-On-Grade Edge Insulation LAUDRY 1 ft 0
36ft2
____
0 1
0
4/21/2020 10:04 AM EnergyGaugeO USA 6.0.02 (Rev.1)'- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORWR405-2017 INPUT SUMMARYCHFCKLIST RFPnRT
FLOORS
# FloorType
Space Perimeter PerimeterR-Value
Area
JoistR-Value Tile
Wood Carpet
6Slab-On-Grade Edge Insulation
BEDROOM 12ft
0
180ft2
____
0
1
0
7Slab-On-Grade Edge Insulation
DINING/GREAT 50ft
0
588ft2
____
0
1
0.
8 Slab -On -Grade Edge Insulation
KITCHEN lift
0
209 ft2
____
0
1
0
9 Slab -On -Grade Edge Insulation
BATH 5 ft
0
50 ft2
__--
0
1
0
10SIab-On-Grade Edge Insulation
HALL 1 ft
0
25ft2
___-
0
1
0
11SIab-On-Grade Edge Insulation
FOYER 9 ft
0
92 ft2
____
0
1
0
12SIab-On-Grade Edge Insulation
BEDROOM 14ft
0
169ft2
-__-
0
1
0
ROOF
/
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip
Metal 1847 ft2
0 ft2
Light
N
0.4
No . 0.9
No 0
18.4
ATTIC
V
# Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
# CeilingType
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented)
MASTER BEDRO
30
Blown
224ft2
0.1
Wood
2 Under Attic (Vented)
WIC
30
Blown
63ft2
0.1
Wood
3 Under Attic (Vented)
MASTER BATH
30
Blown
56 ft2
0.1
Wood
4 UnderAttic(Vented)
M. BATH
30
Blown
61 ft2
0.1
Wood
5 Under Attic (Vented)
LAUDRY
30
Blown
36ft2
0.1
Wood
6 UnderAttic(Vented)
BEDROOM2.
30
Blown
180ft2
0.1
Wood
7 Under Attic (Vented)
DINING/GREAT
30
Blown
588ft2
0.1
Wood
8 Under Attic (Vented)
KITCHEN
30
Blown
209ft2
0.1
Wood
9 Under Attic (Vented)
BATH
30
Blown
50ft2
0.1
Wood
10 UnderAttic (Vented)
HALL
30
Blown
25 ft2
0.1
Wood
11 UnderAttic(Vented)
FOYER
30
Blown
92ft2
0.1
Wood
12 UnderAttic(Vented)
BEDROOM
30
Blown
169ft2
0.1
Wood
13 Knee Wall (Vented)
DINING/GREAT
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent
Space Cavity Width
411le Et In
Height
Ft In
Area
Sheathing Framing
RA/al-le Fraction
Solar Below
Ahsor Grade%
1
E Exterior Concrete Block- Int InsuMASTER BE 4.1
16
0 8
0
128.0 ft2
0 0
0.3
0
2
W Exterior Concrete Block- Int InsuMASTER BE 4.1
7
0 8
0
56.0 ft2
0 0
0.3
0
3
1 S Exterior Concrete Block- Int InsuMASTER BE 4.1
14
0 8
.0
112.0 ft2
0 0
0.3
0
4/21/2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software . Page 3 of 6
• FORMR405-2017 INPHT SHMMARY C'_1-117r10 IST RFPART
WALLS
Adjacent Space
Cavity Width
Height
Sheathing Framing
Solar Below
4
E
Exterior
Concrete Block- Int InsuMASTER BA
4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
_ 5
E
Exterior
Concrete Block- Int Insul NI. BATH
4.1 7
0
8 0
56.0 ft2
0
0
0.3
0
6
E
Exterior
Concrete Block- Int InsuBEDROOM 2
4.1 12
0
8 0
96.0 ft2
0
0
0.3
0
_ 7
S
Exterior
Concrete Block- Int InsuDINING/GRE
4.1 30
0
8 0
240.0 ft2
0
0
0.3
0
8
W
Exterior
Concrete Block- Int InsuDINING/GRE
4.1 20
0
8 0
160.0 ft2
0
0
0.3
0
9
W
Exterior
Concrete Block- Int Insul KITCHEN
4.1 11
0
8 0
88.0 ft2
0
0
0.3
0
10
E
Exterior
Concrete Block - Int Insul BATH
4.1 5
0
8 0
40.0 ft2
0
0
0.3
0
11
N
Exterior
Concrete Block- Int Insui FOYER
4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
12
N
Exterior
Concrete Block- Int Insul FOYER
4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
13
W
Exterior
Concrete Block- Int InsuBEDROOM 3
4.1 13
0
8 0
104.0 ft2
0
0
0.3
0
14
N
Exterior
Concrete Block - Int InsuBEDROOM 3
4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
_15
N
Garage
Frame -Wood BEDROOM
11 26
8
208.0ft2
0.23
0.3
0
DOORS
#
Ornt
DoorType Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Insulated FOYER
None
.32
3
3
6 8
21.7 ft2
WINDOWS
Orientation shown is the entered orientation => chan ed to Worst Case.
/
Wall
Overhang
V/
#
Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
IntShade
Screening
1
S 3
Metal Low-ESingle Yes
1.04 0.29
N
32.4 ft2
1 ft 0 in
1 ft 5 in
Drapes/blinds
Exterior5
2
E 5
Metal Low-ESingle Yes
1.04 0.29
N
6.9 ft2
1 ft 0 in
1 ft 5 in
None
None
3
E 6
Metal Low-ESingle Yes
1.04 . 0.29
N
16.2 ft2
1 ft 0 in
1 ft 5 in
None
None
4
S 7
Metal Low-ESingle Yes
1.04 0.29
N
39.8 ft2
1 ft 0 in
1 ft 5 in
None
None
5
W 8
Metal Low-ESingle Yes
1.11 0.27
N
40.0 ft2
8 ft0 in
1 ft 5 in
None
None
6
W 13
Metal Low-ESingle Yes
1.04 0.29
N
16.2 ft2
1 ft 0 in
1 ft 5 in
Drapes/blinds
Exterior5
GARAGE
#
FloorArea CeilingArea Exposed Wall Perimeter
Avg.WallHeight
Exposed Wall Insulation
1
806 ft2 806 ft2
26 ft
8 ft
11
INFILTRATION
# Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse ProposedACH(50) .000254 1168.7 64.16
120.66
.0881
5
4/21/2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
' FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Single HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow SHR Block
Ducts
1 Central Unit/
Split
Single SEER:15
34.8 kBtu/hr cfm 0.85 1
sys#1
HOT WATER SYSTEM
# . System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.97 50gal 60.9gal
120deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # CompanyName
System Model# 'Collector
Model#
Area Volume
FEF
None None
ft2
DUCTS
/ — Supply—
--- Return --
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area LeakageType
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6 175 ft2
Attic
55 ft2 DefaultLeakage
Attic
(Default) c(Default) c
1 1
TEMPERATURES
ProgramableThermostat: Y
Ceiling Fans:
Cooling Jan Feb
Heating Jan H Feb
HJan
Mar
HX Mar
Apr
Apr
Ma Jun Jul
May 1 Jun Jul
Aug
MAuSep
Oct MNov
Oct Nov
HDec
Dec
Ventin [ ]Feb
Mar
[X] Apr [
May Jun Jul
Aug
Se
[Xj Oct Nov
Dec
ThermostatSchedule: HERS 2006 Reference
Hours
ScheduleType
1
2 3
4 5 6
7
8
9 10 11
12
Cooling(WD) AM
78
78 78
78 78 78
78
78
80 80 80
80
PM
80
80 78
78 78 78
78
78
78 78 78
78
Cooling(WEH) AM
78
78 78
78 78 78
78
78
78 78 78
78
PM
78
78 78
78 78 78
78
78
78 78 78
78
Heating(WD) AM
66
66 66
66 66 68
68
68
68 68 68
68
PM
68
68 68
68 68 68
68
68
68 68 66
66
Heating(WEH) AM
66
66 66
66 66 68
68
68
68 68 68
68
PM
68
68 68
68 68 68
68
68
68 68 66
.66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8lbs/sq.ft.
0 ft2
0 ft
0.3
MASTER BEDROO
Default(8lbs/sq.ft.
ft2
ft
0.3
WIC
Default(81bs/sq.ft.
ft2
ft
0.3
MASTER BATH
Default(81bs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
LAUDRY
Default(81bs/sq.ft.
ft2
ft
0.3
BEDROOM 2 '
Default(8lbs/sq.ft.
ft2
ft
0.3
DINING/GREAT RO
Default(81bs/sq.ff.
ft2
ft
0.3
KITCHEN
4/21/2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORWR405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area Thickness FumitureFraction
Space
Default(8lbs/sq.ft.
ftz ft 0.3
BATH
Default(8lbs/sq.ft.
ftz ft 0.3
HALL
Default(8lbs/sq.ft.
ftz ft 0.3
FOYER
Default 81bs/s .ft.
ftz ft 0.3
BEDROOM.3
4/21/202010:04 AM EnergyGauge® USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT.. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
U
W
Design Location: FL, Fort Pierce
y
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A.continuous. air barrier shall be installed in the building. envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an dropped ceiling/soffit
Y PP 9 /soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs -or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with, the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall'be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation,
maintain permanent contact with the underside of
above -garage
subfloor decking,or floor framing cavity
g insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed. .
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by, insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned -spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring.
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall:not be.used Ao fill voids
a. In addition, inspection of log walls shall bein accordance with the provisions of ICC-400.
4/21/2020 10:05 AM EnergyGauge® USA 6.0:02 (Rev. 1) - FlaRes2017 FBC 6th Edition (201'7) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY.CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location.& insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 3
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5. Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1753
d) Room unit/PTAC EER
e) Other
7. Windows, type and'area
a) U-factor:(weighted average) 7a. 1.058
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.285
c) Area 7c. 151.4
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab-on=grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a). Under attic
b) Single assembly .
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
10131. 11.0
1062.
14. Heating system: Capacity34.8
a) Split system heat pump HSPF 8.5
b) Single package heat pump HSPF
(;) Electric resistance COP
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.97
b) Gas fired, natural gas EF
c) Gas fired, LPG EF.
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
f) Heat recovery unit HeatRec%
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a. 30.0
b) Cross ventilation No
11 b.
c) Whole house fan No
11c. 19.0
d) Multizone cooling credit
11d. No
e) Multizone heating credit
0 Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code; Energy Conservation, if not DEFAULT.
certify that this home has complied with the Florida Building Code, Energy Conservation, through the'above energy
saving features which will be installed (or exceeded). in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address!of New Home. 4 `RkQ5 B S \)A City/FL Zip: FT. PIERCE. FL��
4121/202010:05:25 AM EnergyGauge® USA 6.0.04 (Rev, 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1