Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020` FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional "Regulation - Residential Performance Method ProjectName: GEMINI Street: �,� \-e - �`� BuilderName: WYNNE BUILDING CORP. ".) Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, PermitNumber: Owner: Jurisdiction: DesignLocation: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction oreAsting . New.(From Plans) 10. Wall Typegl763.8 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block'- Int Insul, Exterior R=4.1 1507.80 ft2 3. Number of units, if multiple family 1 b. Frame -Wood, Adjacent c. N/A R=11.0 256.00 f12 R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 11..Ceiling Types (1839.0 sqft.) Insulation, Area. a: UnderAttic (Vented) R=30.0 1839.00 ft2 6. Conditioned floor area above grade(ft2) 1839 b.."N/A R= ft2 Conditioned floorarea"belowgrade(ft2) 0 c• N/A R= ft2 7. Windows(155.3 sgft.) Description Area 12. Ducts R ft2 a. U-Factor: Sgl, U=1.02 115.28 ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 125 SHGC: SHGC=0.27 b. U-Factor: Sgl, U=1.11 40.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 3.318 ft. 14.14eating.systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.270 a. Electric Heat Pump 34.8 HSPF:8.50 8. Skylights Area c. U-Factor.(AVG) N/A ft2 15. Hot watersystems SHGC(AVG): NIA a. Electric Cap: 40 gallons .9. Floor Types (1839.0 sqft.) Insulation Area EF:0.950 a. Slab -On -Grade Edge Insulation R=0.0 1839.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat . Glass/Floor Area: 0.084 Total Proposed Modified Loads: 51.52 PASS Total Baseline Loads: 52.96 hereby certify that the plans and specifications covered by Review of the plans and �j itlE.S this calculation are in.compliance with the Florida Energy specifications covered by this - Code. calculation indicates compliance the Florida Energy Code. y' = 9a 'P-,A %.: 'y== _' . with +" .Ni. , O" PREPAR Y Before construction is completed DATE. 9-200 this building will be inspected for compliance with Section 553.908 I hereby certify that this:building, as designed, is in compliance Florida. Statutes. with the Florida Energy Code.'t9j�" ,OWNER/ A EMI BUILDING OFFICIAL: DATE: \ DATE: - Compliance requires certification by the air handier -unit manufacturer that the air handier enclosure qualifies as certified factory -sealed" in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection. Checklist in accordance -with R402.4.1:1 "and this" project requires an envelope leakage test report with envelope leakage. no greater than 5.00 ACH56. (R402.4.1.2). F��.Eaot� 12/29/2020 1:52 PM 7.0.00 - FlaRes2020 FBC7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY: CHECKLIST REPORT PROJECT Title: GEMINI Bedrooms: 2 Address Type: StreetAddress Building Type: User ConditionedArea: 1839 Lot# OwnerName: Total Stories: 1 Block/Subdlvision: # of Units: 1 Worst Case: Yes PlatBook: BullderName: WYNNE BUILDING CORP. RotateAngle: 270 Street: Permit Office: ST. LUCIE COUNTY CrossVentilation: No County. St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE , FamilyType: Detached FL, New/Existing: New (From Plans) . Comment: CLIMATE / Design Temp DesignLodation TMY Site 97.5 % 2.5 % int Design Temp Winter Summer Heating Design Degree Days Moisture DailyTemp Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 tow BLOCKS Number Name Area Volume 1 Entire House 1839 14712 SPACES Number Name Area Volume. Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 343 2744 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No" Yes Yes 3 M.BATH 5E 448 No 0 1 Yes Yes Yes 4 KITCHEN 172 1376 Yes 0 1 No Yes Yes 5 MASTER BEDROO 256 2048 No 0 1 1 Yes Yes Yes 6 ENTRY' 83' 664 No 0 1 Yes Yes Yes 7 LAUNDRY 42 336 No 0 1 Yes Yes Yes 8 GREAT/DINING 568 4544 No 0 1 Yes' Yes Yes ' 9 CLOSET 2 56. 448 No 0 1 No Yes Yes 10 BATH 2 48 384 No 0 1 Yes Yes Yes 11 POWDER 42 336 No 0 1 No Yes Yes 12 SITTING ROOM 110 880. No 0 1 Yes Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet .1 Slab -On -Grade Edge Insulation BEDROOM 43 ft 0 343 ftZ ____ 0 1 0 2Slab-On-Grade Edge Insulation WIC 1 ft 0 63W ____ 0 1 0. 3 Slab -On -Grade Edge Insulation M. BATH 8 ft 0 56 ftz ____ 0 1 0 4Slab-On-Grade Edge Insulation KITCHEN 1 ft 0 172ft2 ____ 0 1 0 5Slab-On7Grade Edge Insulation MASTER BEDRO 51ft 0 256ft2 ____ 0 1 0 12/29/20201:52 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY. CHECKLIST REPORT FLOORS # FloorType Space' Perimeter Per imeterR-Value Area JoistR-Value" Tile Wood Carpet 6 Slab -On -Grade Edge Insulation ENTRY 7 ft 0 83 ft2 _-__ 0 1 0 7 Slab -On -Grade Edge Insulationr LAUNDRY 6 ft 0 42 ft2 ____ 0 1 0 8Slab-On-Grade Edge Insulation GREAT/DINING 39ft 0 568ft2 ____ 0 1 0 98Iab-On-Grade Edge Insulation CLOSET2 1 ft 0 56ft2 ____ 0 1 0 10SIab-On-Grade Edge Insulation BATH 2 8 ft 0 .48 ft2 ____ 0 1 0, 11SIab-On-Grade Edge Insulation POWDER 1 ft 0 42ft2 __-_ 0 1 0 12SI6b-On-Grade Edge Insulation SITTING ROOM 22ft 0 110ft2 ____ 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1938 ft2. 0 ft2 Light N 0.6 No 0.7 No 0 18.43 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1839 ft2 N N CEILING. # CeilingType Space R-Value Ins Type Area Framing Frac Truss Type . 1 Under Attic (Vented) BEDROOM 30 Blown 343ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56ft2 .0.1 Wood 4 Under -Attic (Vented) KITCHEN 30 Blown 172 ft2 0.1 -Wood 5. Under Attic (Vented) MASTER.BEDRO 30 Blown 256ft2 0.1 Wood 6 Under Attic (Vented) ENTRY 30 Blown 83ft2 . 0.1 Wood. 7 UnderAttic(Vented) LAUNDRY 30 Blown 42112 0.1 Wood .8 UnderAttic(Vented) GREAT/DINING 30 Blown 568ft2 0.1 Wood' 9 Under Attic (Vented) CLOSET*2 30 Blown 56ft2 0.1 Wood 10 UnderAttic (Vented) BATH 2 30 Blown 48 ft2 0.1 Wood 11 UnderAttic(Vented) POWDER 30 Blown 42ft2 . 0.1 Wood 12 UnderAttic(Vented) SITTING ROOM 30 Blown 110ft2 0.1 Wood WALLS Adjacent Twepace Cavity: Width SWall '. . Height Sheathing: Framing : Solar Ahsor Below . o 1 S=>E . Exterior Concrete Block- Int Insul BEDROOM 4.1 .29 0 8 0 232.0ft2 0 0 0.4 0, 2 W=>S Exterior Concrete Block - Int Insul BEDROOM 4.1 14 0 8 0 112.0 ft2. 0 0 0.4 0 _ 3 S=>E 'Exterior Concrete Block -lnt Insul M. BATH' 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 4 N=>W Exterior Concrete Block- Int InsuMASTER BE 4.1 24 0 8 0'. 192.0 ft2 0 0 0.4 0 12/29/20201:52 PM 7.0.00 - FlaRe's202O FBC 7th Edition (2020) Compliant.Software Page 3 of 6 FORM R405-2020 INPI IT S'1 IMIIIAARV" r4I1=1-1[1 "tsr DGDnD-r WALLS Adjacent Space Cavity Width - Height Sheathing- Framing Solar . Below o 5 E=>N Exterior Concrete Block - Int InsuMASTER'BE 4.1. 13 0 8 0 164.-0 ft- 0 0 0.4 0 6 S=>E Exterior Concrete Block - Int InsuMASTER BE 4.1 14 0 8 0 112.0 ftz 0 0 0.4 0 7 E=>N Exterior Concrete Block- Int Insul ENTRY 4.1 6 0 8 0 48.0 ft' .0 0 0.4 0 8 S=>E Exterior "Concrete Block-'Int Insul 'ENTRY 4.1 1 0 8 0 8.0 ftz 0 0 0.4 0 9 S=>E Exterior Concrete. Block- Int Insul LAUNDRY 4.1 6 0 8 0 48.0 ftz 0 0 0.4 0 10 N=>W Exterior Concrete Block - Int InsuIGREAT/DINT 4.1 30 0 8 11 267.5 ftz 0 0 0.4 0 11 W=>S Exterior Concrete Block- Int InsuIGREAT/DINT 4.1 9 0 8 11 80.3 ftz 0 0 0.4 0 12 N=>W "Exterior Concrete Block*- IntInsul BATH 2 4.1 8 0 8 0 64.0 ftz 0 0 0.4 0 _ 13 N=>W Exterior Concrete Block- Int InsuBITTING RO 4.1 10 0 8 0 80.0 ftz 0 0 0.4 0 14 S=?E Exterior Concrete Block- Int InsuBITTING RO .4.1 1 0 8 0 8.0 ftz 0 0 0A 0 15 W=>S Exterior Concrete Block - Int InsuSITTING RO 4.1 11 0 8 0 88.0 ftz 0 0 0.4 0 16 N=>W Garage Frame -Wood KITCHEN 11 32 8 256.0 ft2 0.23 0.4 0 DOORS # Ornt DoorType Space Storms U-Value Width Height" Area Ft In Ft In 1 E=>N Insulated ENTRY None .32 3 6 8 20 ftz WINDOWS Orientation showri.is the entered orientation => changed to Worst Case. / Wall Overhang # Ornt ID Frame Panes. NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 W=>S 2 Metal _ Low-ESingle Yes 1.02 0.27 Y 32.4 ftz" 1 ft 0 in 1 ft 4 in" Drapes/blinds Exterior5 2 S=>E 3 Metal Low-ESingle Yes 1.02 0.27 Y 6.9 ftz 1 ft 0 in 1 ft 4 in None None 3 E=>N 5 Metal Low-ESingle Yes 1.02 0.27 Y 32.4 ftz 1 ft 0 in 1 ft 4 in None None 4 N=>W 10 Metal Low-ESingle Yes 1.02 '0.27 -Y 18.4 ft2 1 ft 0 in 1 ft 4 in None None 5 . W=>S 11 Metal ' Low-ESingle Yes 1.11 0.27 Y 40:0 ft2. 10 ft 0 in 1 ft 4 in None None 6 N=>W 12 Metal Low-ESingle Yes 1.02 0.27 Y 6.9 ftz 1 ft 0 in . 1 ft 4 in .,None None 7 W=>S 15 Metal Low-ESingle ' Yes 1.02 0.27 Y 18.4 ftz 1 ft 0 in 1 ft 4 In None None GARAGE # FloorArea CeilingArea Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 320 ftz 320 ftz 32 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000254" 1226 67.26 126.28 .0902 5 12/29/2020 1:52 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY: CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Single HSPF:8.5 34.8kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER:15 34:8 kBtu/hr cfm. 0.85 1 sys#1 -HOT WATER -SYSTEM # ` System Type' 'SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # CompanyName System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / -- Supply--- ---Return -- Air CFM 25 CFM25 :HVAC # V # Location R-Value Area Location • Area LeakageType Handler TOT OUT QN RLF Heat Cool, 1 Attic 6 125ft? Attic 40ft2 DefaultLeakage Attic (Default)c(Default)c TEMPERATURES ProgramableThermostat: Y Ceiling Fans:" CoolingJan HFeb Mar HJan Feb MMar Apr Apr May Jun Jul May Jun MJul I Auge AuSep Oct Nov Oct Nov ecHeatin Dec HD Vent in Jan Feb Mar [xl Apr May Jun Jul Aug Se . [X] Oct Nov Dec ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM, 78 78 78 78 78 78 78 78. 80 80 80 80 PMt 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78. 78 78 78 78 78 78 78 78 78 PM .78 78 78. 78 78 78 78 78 78 78 78• 78 Heating(WD) AM 66 66 66, 66 66 68 68 68 68 68 68 •68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68, .68 68 •66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8lbs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM Default(8lbs/sq.ft. ft2 ft 0.3 WIC Default(BIbs/sq.ft. ft2 ft 0.3 M. BATH Default(8lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8lbs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8lbs/sq.ft. ft2 ft 0.3 ENTRY Default(8lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default(81bs/sq.ft. ft2 ft 0:3 GREAT/DINING 12/29/20201:52 PM Tub - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6 FORM R405-2020 INPUT SUMMARY: CHECKLIST REPORT MASS Mass Type Area Thickness FurnitureFraction Space Default(81bs/sq.ft. ft2 ft 0.3 CLOSET 2 Default(8lbs/sq.ft. ft2 ft 0.3 BATH 2 Default(81bs/sq.ft. ft2. ft 0.3 POWDER Default 8lbs/s .ft. ft2 ft 0.3 SITTING ROOM 12/29/2020 1:62 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 • 2020 - AIR BARRIER AND.INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1:1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a Project Name: GEMINI. Builder Name: WYNNE BUILDING CORP. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL', Permit Number:. Owner: Jurisdiction: w .Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building.envelope. Air -permeable insulation shall requirements The exterior thermal envelope -contains a. continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be'sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall.be aligned with The insulation in an dropped ceiling/soffit Y PP 9 /soffit the insulation and an a s in the.air barrier shall be sealed. y 9 P shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill:plate shall'be sealed. 'Cavities within corners and headers•of frame walls The junction of the top plate and'the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance'of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope: insulation for framed walls shall be installed.in substantial contact and continuous alignment with the air barrier: Windows, skylights The space between window/door.jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation:shall'be' installed;to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation. and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor,framing and extends fromthe bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of.floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations . Duct shafts, °utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cutto fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation' readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 3s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall.be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring. and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall '$hower/tub . The air barrier installed at exterior walls adjacent to. showers and Exterior walls adjacent to showers and tubs shall on: exterior wall tubs shall separate'them from the showers and tubs. be.insulated.. Electdcal/phone box or The air.barrier.shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that -penetrate building.. thermal envelope shalt be sealed to the sub -floor, wall covering or, Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that'is recommended. by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire snrinkler rover plates and walls or reilinns. a. In addition, inspection of log'walls.shall be in accordance with the provisions of ICC-400. 12/29/20261:53 PM EnergyGauge® USA 7.0:00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 ' FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED :ENERGY PERFORMANCE' INDEX' = 97 The lower'the EnergyPerformance Index, the more efficient the home. , FT. PIERCE, FL,'. 1. New construction or existing New (From Plans) 1Q. Wall'Type and Insulation-. Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul; Exterior R=4.1 1507.80 ft2 b. Frame - Wood, Adjacent R=11.0 256.00 ft2 3. Number of units, if multiple family 1 c. N/A R=. ft2 4. Number of Bedrooms 2 d: N/A R= ft2 5. Is this a worst case? Yes 11': Ceiling Type. and insulation level ° Insulation Area a. Under Attic (Vented) R=30.0 1839.00 ft2 6. Conditioned floor area (ft2) 1839 b. N/A R=. ft2 7. Windows" Description Area c. N/A R= ft2 a. U-Factor: SgI,:U=1.02 115.28 ftz 12. Ducts, location & insulation level R ftz a. Sup: Attic, Ret: Attic, AH: Attic 6 125. SHGC: SHGC=0.27 b. U-Factor: Sgl, U=1.11 40.00 ft2 SHGC: SHGC=0.27 13. Cooling systems kBtu/hr ' Efficiency c. U-Factor: N/A' ft2 a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A ft2 SHGC: 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.318 ft. a. Electric Heat Pump 34.8 HSPR8.50 Area Weighted Average SHGC: 0.270 8. Skylights ' Description Area 15. Hot-water systems a. U-Eactor(AVG): N/A z ft2 a. Electric Cap: 40 gallons SHGC(AVG): N/A EF:0.95 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1.839.00 ft2 .. Credits (Performance method) Pstat b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied with.the Florida Energy Efficiency Code for Building Construction through the above energy saving features which: will be installed (or exceeded) in. this. home� before final inspection. Otherwise, a new EPL-Display Cardwill be completed based on installed'Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: o SC.p� �� *Note:.: This is not a Building Energy Rating... If your Index is below 70, your home may qualify for energy. efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating.. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303A.3 of the:Florida Building Code, Energy Conservation, if not DEFAULT. 12/29/2020 1:52 PM 7.0.00 - F14Res2020 FBC 7th Edition (2020) Compliant. Software Page 1 of 1