Loading...
HomeMy WebLinkAboutAPPROVED, product approval 2.26.2100012/26/2021 Florida Building Code Online ��w"o R�itrVJ,YIV,II" +�ritri�lm,iiirl�ir�l�ttx'tu ,g1�,�IM +ri rViv. �.. t`" ` - t t BCIS Home Log In User Registration Hot Topics Submit Surcharge 1 Stats & Facts Publications Contact Us BCIS Site Map , Links I Search I dbpr Product Approval (A USER: Public User Product Approval Menu > Product or Application Search > Application List Search Criteria Refine Search Code Version 2020 FL# 22378.2 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Cnerrh Deculla _ Annlin trope .FL# 1rypg, Manufacturer Validated By, Status FL22378-R7 Revision Masonite International FL#:FL22378.2 National Accreditation & Management Institute (804) 684-5124 Approved His Model: Stormguard Fiberglass Side -Hinged Door Unit Description: 6'-8" Opaque O/S Single Door Category: Exterior Doors Subcategory: Swinging Exterior Door Assemblies -Approvea oy unrtt. Approvals oy Un snau.. De.revieweu anu ranneu oy me ry ana/or ure ­rnrmsswn " necessary. Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy. Statement :: Accessibility. Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: httr)s://floridabuildina.orci/Dr/i)r aw Ist.asox 1/1 dtio c�aT:FMarj V - 7 Q { NOTICE OF PRODUCT CERTIFICATION Company: Masonite International Corporation Certification No.: 1955 Powis Road Certification Date: West Chicago, IL 60185 Expiration Date: Revision Date: NI007077.07-R3 05/22/2017 12/31 /2025 07/27/2020 Product: Fiberglass Impact Rated Opaque Inswing or Outswing Door w/ and w/o Impact Rated Sidelites (w/Wood Frame or Worldwide Composite Frame unless noted) Specification: TAS 201/202/203-94/ASTM E330-02 The "Notice of Product Certification" is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within NAMI's Certified Product Listing at www.Namicertification.com. NAMI's Certification Program is accredited by The American National Standards Institute (ANSI). Inswing Glazed Structural Water Missile Test Report Number Configuration or or Maximum Design Test Impact Drawing Number & Outswing Opaque Size Pressure Pressure Rated Comments X I/S Opaque 3'0" x 6'8" +60/-65 0 psf Yes NCTL-210-3102-1/ATLNC 0 1 29.02-15/ATLNC 1012.01-16 Single Maximum Panel Size: 3'0" x 6'8" Anchor Details-MA-FL0170-07/W-1807 X O/S Opaque 3'0" x 6'8" +60/-60 3.75 psf/ 6.0 psf Yes NCTL-210-3102-1/ATLNC 0129.02-15/ATLNC 1012.01-16 Single 10.5 psf 2/9.0 psf 4 Maximum Panel Size: 3'0" x 6'8" 7.5 psf 5 Anchor Details-MA-FL0170-07/W-1807/W-18351 W-1860 XX I/S Opaque 6'0" x 6'8" +50/-50.5 0 psf Yes NCTLr210-3105-1/ATLNC 0129.01-15/ATLNC 1012.01-16 Double Maximum Panel Size: 3'0" x 6'8" Anchor Details-MA-FL0170-07/W-1807 XX O/S Opaque 6'0" x 6'8" +55/-50.5 3.75 psf/ 6.0 psf' Yes NCTL-210-3105-1/ATLNC 0129.01-15/ATLNC 1012.01-16 Double 8.25 psf'/8.25 psf ° Maximum Panel Size: 3'0" x 6'8" Anchor Details-MA-FL0170-07/W-1807/W-1835 XO/OX I/S Opaque Door 6'0" x 6'8" +50.51-50.5 0 psf Door -Yes NCTLr210-3105-1/ATLNC 0129.01-15/ATLNC 1012.01-16 Single w/Sidelite Glazed Sidelite Sidelite-Yes Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8" Anchor Details-MA-FL0170-07/W-1807 XO/OX O/S Opaque Door 6'0" x 6'8" +551-50.5 3.75 psf/ 6.0 psf' Door -Yes NCTL-210-3105-1/ATLNC 0129.01-15/ATLNC 1012.01-16 Single w/Sidelite Glazed Sidelite 8.25 psf 2/9.0 psf 4 Sidelite-Yes Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8" Anchor Details-MA-FL0170-07/W-1807/W-1835 OXO I/S Opaque Door 910" x 6'8" +50.51-50.5 0 psf Door -Yes NCTL-210-3105-1/ATLNC 0129.01-15/ATLNC 1012.01-16 Single w/Sidelites Glazed Sidelite s. Sidelite-Yes Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8" Anchor Details-MA-FL0170-07/W-1807 OXO O/S Opaque Door 9'0" x 6'8" +55/-50.5 3.75 psf/ 6.0 psf' Door -Yes NCTL-210-3105-1/ATLNC 0129.01-15/ATLNC 1012.01-16 Single w/Sidelites Glazed Sidelite 8.25 psf 2/9.0 psf 4 Sidelite-Yes Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8" Anchor Details-MA-FL0170-07/W-1807/W-1835 OXXO I/S Opaque Door 12'4" x 6'8" +50/-50.5 0 psf Door -Yes NCTL-210-3105-1/ATLNC 0129.01-15/ATLNC 1012.01-16 Double w/Sidelites Glazed Sidelite Sidelite-Yes Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8" A Anchor Details-MA-FL0170-07/W-1807 OXXO O/S Opaque Door 12'4" x 6'8" +551-50.5 3.75 psf/ 6.0 psf' Door -Yes NCTL-210-3105-1/ATLNC 0129.01-15/ATLNC 1012.01-16 Double w/Sidelites Glazed Sidelite 8.25 psf 2/8.25 psf 4 Sidelite-Yes Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8" Anchor Details-MA-FL0170-07/W-1807/W-1835 1 -Denotes Z-Series Threshold Design 2 -Denotes High Dam Threshold Design 3-W-1815 4-Denotes Worldwide Pro T4 Threshold 5-Denotes HP Outswing Threshold National Accreditation & Management Institute, Inc./4794 George Washington Memorial Highway/Hayes, VA 23072 Tel: (804) 684-5124/Fax: (804) 684-5122 NAMI AUTHORIZED SIGNATURE: �,/� T � I� MASON 1 E. 149' MV UYERMl FWWE WMTH � ca O pU STORMGUARD FIBERGLASS DOOR UNIT 2 �.L.o PANEL MAX. 37.5" MAX. O PANEL WIDTH V-8" DOUBLE DOOR WITH I WITHOUT SIDELITES W/ASTRAGAL FRAME WIDTH ZO Q� J L GENERAL NOTES �t o 1. EVALUATED FOR USE IN LOCATIONS ADHERING TO UJ O Q THE FLORIDA BUILDING CAGE AND WHERE PRESSURE IL o U REQUIREMENTS AS DETERMINED BY ASC£ 7, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, lLu L0 U DOES NOT EXCEED THE DESIGN PRESSURES LISTED. h 2. THIS PRODUCT DOES NOT. REQUIRE THE USE OF 0 F- A HURRICANE PROTECTIVE SYSTEM (SHUTTERS). co `- L 3. POLYURETHANE CORE FLAME SPREAD INDEX OF SO � � O � � AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. = m O 4 PLASSST�DESCRCS �IPTION DESIGNATION FACING LITE FRAME a SELF IGNITION TEMP ASTM D1929 752 -F > 650 -F 842 'F > 650 -F -RATKODBURNING ASTM D635 0.56 IN/MIN 71028 IN/MIN ENSITY ASTM D2843 53.4% .2RSMO TENSILE STRENGTH` �C ASTM D638 3.2% DIFF 1.8% DIFF n g Q Lt a fA 5.. PLASTICS TESTING OF WORLDWIDE COMPOSITE FRAME (WHERE USED): TEST DESCRIPTION _ DESIGNATION RESULT N w SELF IGNITION TEMP ASTM D1929 1 779 'F > 650 'F " RATE OF BURNING ASTM D635 0.0 IN MIN�;1 8 0 SMOKE DENSITY ASTM D2843 39.0% Y� TENSILE STRENGTHS ASTM D638 3.6% DIFF ' COMPARATIVE TENSILE STRENGTH AFTER WEATHERING DOUBLE DOOR UNIT WISlDEUTES d a, 45M HOURS XENON ARC METHOD 1 rn to N to to DOUBLE DOOR UNIT I SINGLE DOOR UNIT SINGLE DOOR UNIT SINGLE DOOR UNIT W/SDELRES WITH SIDELITE WITH SIDELITE ow DOUBLE DOOR UNIT W/SIDELITES STRUCTURAL DESIGN PRESSURE RATING WHERE WATER INFILTRATION PERFORMANCE IS REQUIRED TO BE 15% OF DESIGN PRESSURE CONFIG MAX WIDTH INSWING ALL OUTSWING INSWING BUMPER 0 S Z-SERIES O S I HP O S T4 O S HIGH DAM O S X 37.5 +0.0 -6. +�0-60.0 N +-25.0 +40.0 -40.0 +50.0 -50.0 +60.0 -60. -60.0 XX 74 +0.0 -505 . 50.5 5.0 +40.0 -40.0 NA +555.-50.5 50.5 or XO 75 +0.555 0.+ 50.5 + 550OX +40.0 -40.0 +550.5 +550 0.5 OXO 112.5 05 0-5.5 +50.5 +40.0 5 149 + 5OXXO 5 TABLE OF CONTENTS SHEET # DESCRIPTION 1 TYPICAL ELEVATIONS & GENERAL NOTES 2 ANCHORING LOCATIONS & DETAILS 3 1ANCHORING LOCATIONS & DETAILS AddeIllMln b �1i e��e�i✓ G41kalaa1u: 0l11RIMwB,2e 16- KURT BALTHAZOR FLORIDA P.E. 156533 SW N.T.S. MG. BY: SWS CHK. Br: ORnw mG ND, DWG-MA-FL0170- SHEET __L or 3 6" SEE DETAIL_ 3 6" J V "E' 3 1 I 13• iL 3� " t< 3 E 31 SEE DETAIL "C" 1 1 1 16' 6 6" 6" — w a N J Q 8 A O8 a w 6 0 0 g 11 Ir6' B" 3' 6' II a 3" --' k #8 x 2° #8x2" 0 DETAIL "D" 1375. .EW'' INSWING • 1.4 2 T Z-SERIES 0/S THRESHOLD t _ Y S" Y 3. 3 3" 6" SEE DETAIL "F" #10 x 5/8" #10 x 5/8" ' #10 x i" #10 x 2-1/2" #10 x i" #10 x 5/8" DETAIL "C" 0.962.1 T �� BUMPER O/S THRESHOLD 1.75°EZp 11.047' T HIGH DAM O/S THRESHOLD w a SEE n ,D, Q d it O a #8 x 2" • DETAIL "E" ASTRAGAL ATTACH ASTRAGAL RETAINER BOLT STRIKE PLATE TO FRAME AS SHOWN. 1.437" FT"� T HP O/S THRESHOLD 1.437" P��n T T4 O/S THRESHOLD v >EE DETAIL C" 6" ASTRAGAL RETAINER BOLT HOLE MUST BE DRILLED THROUGH THE THRESHOLD & INTO THE STRUCTURE DEEP ENOUGH 6i FOR A 1.375" THROW DETAIL "F" ASTRAGAL co U p(D Z 0 J O � z V) o C� O 42 Lo U LLJ O �~ SJ r 1NSUATED a.ASS ,• NSaATm ISAM O 0.124' MEAT SIPENG"I OECORAIIYE INSERT 0.121' WEA1 SiREN00OIE0 OECORAIK N6 0 oW. wm (NM 2 622D1) (OP00 w O.000' SAF= (NDA 20-0622.0i) (aT�) �— .0124' 1EHP. 0.124' NEAT S" EN01NEN D ��- •DIN TEMP 0.124' HFAT STRENODfDED VAn. R1W. 0R MErA SPACER 1/Y Iim WrYL EONI. oR KW SPM 1/2' im w W � m Q Z oar DOS ooM DDD + ; P D0R Dos DATE: 419107 SCALP: N.T.S. Y R� t am= � memo Dwo. ETY: SWS TYPICAL GLAZING DETAIL ALTERNATE GLAZING DETAIL IMPACT RATED rlAC$ IMPACT RATED GLASS RA DRA DWINNGG NO.: DWG-LIA-FLO170-07 SHEET 2 DF 3 ATTACHMENT DETAIL 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, SIGNED AND SEALED BY ROBERTO LOAAS, PE (FLORIDA #62514) WITH THE LOWEST (LEAST) FASTENER RATING FROM THE DIFFERENT FASTENERS BEING CONSIDERED FOR USE. JAMB, HEAD, AND THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE # 10 WOOD SCREWS, 1 /4" TAPCONS, AND # 1 O TEK SCREWS. A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT E ,CH ANCHOR LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2. WOOD SCREW EDGE DISTANCE MIN 3/4". TEK SCREW EDGE DISTANCE MIN 1 /2". 2. ANCHORING INTO STEEL STRUCTURE MUST BE SUFFICIENT TO ACHIEVE 3 THREADS MINIMUM BEYOND STEEL INTERIOR SURFACE 3' O N U a SEE DETAIL "D" SHT. 2 - 0 ;—T w +t G 3' 1MIN I s f �» SHIM M 1.25" CL -I �_ MIN > . 1 . 0.25" SHIM TYPICAL MASONRY CL ANCHOR INSTALLATION 1X BUCK MASONRY •' ANCHOR INSTALLATION 3. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE MINIMUM EMBEDMENT OF 1-1/4. 4. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO STRUCTURE. 5. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS. 1MIN �» SHIM CL --I �— TYPICAL WOOD BUCK ANCHOR INSTALLATION HARFIWARF SC:HFDI11 F 1. KWIKSEf SERIES 400 GRADE 3 CYLINDRICAL LATCH AND SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED AT 5-1/2" CENTERLINE. 2. 4" X 4" FULL MORTISE BUTT HINGES. 1"X1/2" CORRUGATED #10X2" WOOD SCREW 3" FROM EACH END 6' FROM EACH END AND 7' OC AND 12" OC i ACRYLIC CAULK A �xC i CAULK CL t COMBINATION WOOD COMBINATION WOOD MULLION (BOXED) MULLION (BOXED) (3%tDl OXC-1 2" EAW END e INTEGRAL WOOD MULLION (CHS) (4"D1 SCREWS" EACH END INTEGRAL WW MULLION (CHS) � 00 0w ¢o 2 1 G In l it SCAM N.T.S. rnr- B': SWS pnc. ar: DRAWING NO.: OF