Loading...
HomeMy WebLinkAboutAPPROVED Halgus letter-signed M.A. CORSON & ASSOCIATES, Inc. ARCHITECTURE * STRUCTURAL DESIGN 412 Colorado Ave., Stuart, Fl. 34994 (772) 223-8227 * Lic. #AR91665 To: St. Lucie County - Building & Code Regulation Division Date: February 18, 2021 Re: Robert Halgas 4808 Watersong Way, Fort Pierce, Fl. Fort Pierce, Fl. 34949 It is acceptable to replace existing french door for the address listed above with the units as follows: 1) French Door - The PGT “FD-750"' series aluminum french door has a Miami Dade NOA # 20-0427.03 and has a +100 / -100 design pressure. It has a large missile "D" approval and HVHZ. SCOPE OF WORK: Replace existing door with new French door. DESIGN PARAMETERS AND ASSUMPTIONS USED: 1. DESIGN CODE: Florida Building Code Sixth Edition (2017) with 2020 Supplements using ASCE 7‐10 2. Structure Designed: Enclosed 3. Risk Category: II Exposure Category: D 4. Design Wind Velocity 170 mph End Zone Width: 4 ft 5. Mean Roof Height 36 ft Roof Pitch: 4:12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: Zone 4: +54.6 / -59.2 P.S.F. & Zone 5: +54.6 / -73.1 P.S.F. Worst case scenario has been calculated. 7. Design Loads: Floor: N/A Roof/Dead: N/A Roof/Live: N/A Balcony: N/A Dock: N/A Deck: N/A Stairs: N/A Fence: N/A Railings: N/A 8. Were Shear Walls Considered For Structure? N/A Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? N/A 10. Design Soil Bearing Pressure: N/A Soil Test Reports Submitted? N/A Thank you for your time and consideration. If you have any questions please call. Respectfully, Mark A Corson Mark A. Corson A.I.A., NCARB President